Legacy CT1775 Universal MacAir/1553 RTU Hybrid (7/09)

CT1775N
Universal MacAir/1553 Dumb RTU Hybrid
www.aeroflex.com/Avionics
July 19, 2007
FEATURES
❑
CT1775N replaces DDC BUS-65201
❑
Includes:
- Universal transceiver
- Encoder/Decoder
- Dual rank I/O registers
- Fail-safe timer
- Clock oscillator
❑
Simple controls for single or dual redundant data bus configurations
❑
Provides Flags for:
- Own Address (with parity)
- Mode code
- Broadcast
- Time out
- Valid word
- Sync type
❑
16 Bit or 8 Bit 3-state
- Parallel I/O and serial out
❑
Wraparound built-in test
❑
MIL-PRF-38534 compliant circuits available
❑
Designed for commercial, industrial and aerospace applications
❑
Packaging – Hermetic metal
- 68 Pin, 1.85" x 1.6" x .19" Plug-In type package
DESCRIPTION
The CT1775N Universal MACAIR/1553 Dumb Remote Terminal Unit (RTU) consists of a transceiver, and encoder/decoder, control
logic, dual rank I/O registers and internal clock oscillator packaged in a 1.6" x 1.9" hermetic hybrid. It provides all the functions
required to interface between a MACAIR (sinusodial) or MIL-STD-1553 (Trapezoidal) serial MUX data bus and a subsystem parallel
3-state data highway. Utilizing several ASIC ICs, the CT1775N provides sufficient handshaking, control and data lines to permit
versatile operation as a remote terminal, a bus controller or a bus monitor, in either single or dual redundant data bus configurations.
As a transmitter, the CT1775N accepts 8 bit or 16 bit parallel date from the subsystem, and outputs serial Manchester II coded
Command, Status or Data words, under subsystem control. As a receiver, it accepts serial MIL-STD-1553 or MACAIR transmissions
and transfers all Command, Status and Data words to the 8 bit or 16 bit data highway, under subsystem control. The CT1775N also
provides flags to the subsystem when Broadcast, Mode Code, and Own Address (with parity) commands are decoded.
The CT1775N contains a terminal fail-safe timeout circuit which flags message lengths exceeding 768µs, and terminates serial data
transmission. Wraparound selftest is initiated by a control line which causes the encoder serial output to be connected to the decoder
input. The CT1775N provides a serial output of decoded words, thus allowing Command Word look ahead, for the fastest terminal
response.
SCDCT1775 Rev C
RX DATA
RX DATA
TX DATA
TX DATA
LIMITER
2
CLOCK
OUT
CLOCK
POWER
T/O
CLOCK
IN
FILTER
SHAPING
NETWORK
SHAPING
NETWORK
XTAL
CLOCK
GEN
DRIVER
DRIVER
TX
INHIBIT
DEC
RST
5
SERIAL DATA OUT
TAKE
ENA
ADDR
DATA
ADDR
IN
PAR
S/T
DSC
ADDR
SELECT
OUT
PAR
IN
MRST
DECODER
AND
CONTROL LOGIC
MANCHESTER
REGISTER
REGISTER
DATA
SELECT2
DATA
SELECT1
REGISTER
REGISTER
LOAD LOAD LATCH LATCH
DATA1DATA2 DATA1 DATA2
SERIAL DATA IN
ESC SEND
OUT DATA
FIGURE 1 – CT1775N BLOCK DIAGRAM
RX
STROBE
FAILSAFE
DRIVER
ENCODER
AND
CONTROL LOGIC
MANCHESTER
ENC
ENABLE
SYNC
SELECT
D15 (MSB)
THRU
D0 (LSB)
SERIAL DATA OUT
BIT STATUS
RTENABLE
PARITY
COMM DATA SYNC
FAIL-SAFE
VAL CMD WD
VALID WORD
MODE CODE
BROADCAST
BDST INHIBIT
CHAN SELECT
DATA
}
SCDCT1775 Rev C 7/19/07
}
VALUES AT NOMINAL POWER SUPPLY VOLTAGES UNLESS OTHERWISE SPECIFIED
PARAMETER
Receiver
Differential Input Impedance
(DC to 1MHz)
Differential Input Voltage
Input Threshold (Direct Coupled)
CMRR (DC to 2MHZ)
CMV (DC to 2MHZ)
RX STROBE Characteristics
Transmitter
Differential Output Voltage
Direct Coupled (across 145Ω Load)
Transformer Coupled (at stub)
Output Rise and Fall time
Output Noise
TX INHIBIT Characteristics
Logic
IIH, IIL, IOH, IOL
VOH
VOL
VIH
VIL
Clock
VOHC (Internal Clock)
VALUE
UNITS
4 min
40 max
1 typ
40 min
±10 min
1 typ
KΩ
VP-P
VP-P
dB
V
TTL Loads
30 typ
21 typ
130 typ
10 max
1 typ
VP-P
VP-P
ns
mVP-P
TTL Loads
See pin function &
loading Table
2.5 min
0.4 max
2.0 min
0.7 max
V
V
V
V
Supply
-0.3 min
Ground
+0.3 min
Supply
-0.5 min
Ground
+0.5 min
VOLC (Internal Clock)
VIHC (External Clock)
VILC (External Clock)
Power Supplies
+5V OSC/CLOCK Supply
Voltage Tolerances
Current Drain
+5V Logic Supply
Voltage Tolerances
Current Drain
+15V (or +12V) Supply
Voltage Tolerances
Current Drain
-15V Supply
Voltage Tolerances
Current Drain
Idle
25% Transmit
100% Transmit
-12V Supply
Voltage Tolerances
Current Drain
Idle
25% Transmit
100% Transmit
Temperature Range
Operating (Case)
Storage
Physical Characteristics
Size
68 pin DDIP
3
V
V
V
±10
8 typ; 13 max
%
mA
±10
250 max
%
mA
±5
65 max
%
mA
±5
%
65 max
105 max
250 max
mA
mA
mA
±5
%
65 max
105 max
250 max
mA
mA
mA
−55 to +125
−65 to +150
°C
°C
1.6 x 1.9 x 0.18
in
TABLE 1 – CT1775N SPECIFICATIONS
SCDCT1775 Rev C 7/19/07
V
GENERAL
DUAL REDUNDANT OPERATION
As shown in the block diagram of Figure 1, the CT1775N
provides all functions required to implement a Dumb Remote
Terminal Unit (RTU). It is designed for the greatest flexibility
and ease of use. CT1775N can be operated with either an
internal or external clock. Simple control lines are provided to
interface with either single channel or dual redundant
configurations.
The CT1775N may be used in a dual redundant configuration
with a minimum of additional circuitry. A CHAN SELECT
signal is provided which simultaneously disables the LATCH
DATA, DATA SELECT, and ENC ENABLE lines of the
CT1775N. Therefore, CHAN SELECT can be used to
multiplex a single set of LATCH DATA, DATA SELECT and
ENC ENABLE control signals between two CT1775N units,
which have these signals tied together in parallel.
Control lines are available to implement either on line or off
line wraparound built-in test. CT1775N can be configured to
perform a parity check on its hard-wired terminal address. It
provides numerous output flags to simplify the use interface.
These flags indicate various decoded messages, as well as the
results of error checks. Sync selection, along with the flexible
controls, allows the CT1775N to operate as a Bus Controller as
well as a Remote Terminal.
WRAPAROUND BUILT-IN TEST
The CT1775N may be configured to implement either on line
or off line wrap around built-in test. By enabling the receiver
with RX STROBE during a normal transmission, the encoded
word will be fed back into the decoder by the receiver. In this
on line wrap around mode of operation, the CT1775N
compares each decoded word that is fed back with the original
word that was encoded. The BIT STATUS output flag
indicates when the two words are not the same.
INTERNAL OR EXTERNAL CLOCK
CT1775N may be operated with either its internal clock or an
external clock. Internal clock operation requires that a 12 MHz
parallel-resonant fundamental-mode crystal, such as
MIL-C-3098/42 TYPE CR64/U, be connected between pin 18
(XTAL) and ground. In addition, +5 volt power must be
connected to pin 2 (OSC/CLOCK POWER), and CLOCK
OUT (pin 19) must be connected to CLOCK in (pin 24).
Care must be taken when using this on line wrap around test
technique because an outgoing status word will be interpreted
by the decoder as a new command word. Since the status word
has the correct address and the same sync as a command word,
the CT1775N will set RT ENABLE and VAL CMD WD. For
on line wrap around operation, it is therefore necessary to reset
RT ENABLE after transmission of a status word. This can be
accomplished by inverting SEND DATA and applying it to
DEC RST during status word transmission. If it is required that
the status word be fed back, RT ENABLE should be reset
immediately after it goes HIGH by applying a LOW to DEC
RST for 1 microsecond (minimum). The status word will be
available at the receive register.
For external clock operation, no connection is made to pin 2
(OSC/CLOCK POWER, and the external clock is applied to
pin 24 (CLOCK IN). Pin 19 (CLOCK OUT) is not connected.
The external clock must be capable of driving a load of 20
picofarads to within 0.5 volts of the + 5 volt power supply and
to within 0.5 volts of ground. Standard TTL voltage levels will
not work properly. It must have a rise time and fall time of less
than 10 nanoseconds. For compliance with MILSTD-1553, the
external clock frequency must be 12 MHz.
The CT1775N can be placed in an off line wrap around test
mode by use of the S/T SELECT signal. In this mode, the
transceiver is disabled and the encoder output is fed directly to
the decoder input. All other functions remain the same, and the
CT1775N compares each word that is decoded with the
original word that was encoded. The BIT STATUS line also
indicates the result of this comparison for the off line wrap
around test.
8 BIT OR 16 BIT INTERFACE
The CT1775N may be configured to interface with either 8 bit
or 16 bit parallel data highways. For 16 bit operation, the 16
data lines (D 15 through DO) are used directly. LATCH
DATA 1 and LATCH DATA 2 are tied together, as are DATA
SELECT 1 and DATA SELECT 2. This allows data transfer in
16 bit bytes.
FAIL SAFE TIME-OUT
The CT1775N contains a timer which continuously monitors
the length of each transmitted message. This timer detects a
transmitted message which exceeds 768 microseconds and
causes the transmission to terminate. At the same time, The
FAIL-SAFE flag is set to indicate a Terminal Fail-Safe
Time-out. Further transmissions are inhibited until the
FAIL-SAFE flag is reset by MRST or a valid command word
with the correct address is received.
For 8 bit parallel data highways, the 16 data lines must be tied
together in eight pairs (1315 to D7, D8 to 130, etc.) The two
LATCH DATA and DATA SELECT are used independently.
This allows transfer in two 8 bit bytes.
ADDRESS WITH PARITY
The CT1775N provides five lines for hard-wired terminal
address. Internal pull-up resistors are provided on these lines,
so logic "1" lines may be left open-circuited. Logic "0" lines
must be grounded. The CT1775N maybe configured to check
the parity of these five address lines. This function can be
selected by using the ENA PAR CHECK line. The address
parity line (TMADDP) is hard-wired for odd address parity if
the function is sued. the ODD PARITY output flag indicates a
valid check for odd parity of the six address lines.
SCDCT1775 Rev C 7/19/07
4
OUTPUT FLAGS
For multiple word transmissions, the next word may be
transferred to the transmit register any time after SEND DATA
goes HIGH, but no later than the next LOW to HIGH transition
of SEND DATA. SEND DATA remains HIGH for 16 periods
of ESC OUT, during which time the data word is serially
shifted to the Manchester encoder. The encoder adds the parity
bit during the next ESC OUT period after SEND DATA goes
LOW. To terminate transmission after any word, ENC
ENABLE must go to HIGH no later than the first rising edge
of ESC OUT after SEND DATA goes LOW.
The CT1775NCT1775N provides numerous output flags to
offer the greatest user flexibility. VALID WORD indicates
receipt of a word with valid sync, Manchester coding and
parity. RT ENABLE indicates a valid word and correct
address. VAL CMD WD indicates a valid word and a
Command Sync. BROADCAST indicates a valid command
word and an address of 11111. The BROADCAST flag may be
inhibited by using the BDCST INHIBIT line. MODE CODE
indicates a valid command word and a subaddress of 11111 or
00000.
The entire transmit cycle may be interrupted and initialized by
applying a 1 microsecond (minimum) negative pulse to
MRST. It is possible to input data to the encoder in serial form
by forcing both transmit registers to be transparent. With
LATCH DATA 1 held HIGH and LOAD DATA 1 held LOW,
serial data input on D15 will be applied directly to the encoder
serial input. ESC OUT must be used to shift in the serial data,
MSB first, starting at the LOW to HIGH transition of SEND
DATA.
INITIALIZATION
To ensure error-free operation, it is desirable to reset the
CT1775N to its initialized state upon power turn-on. The
MRST (master reset) signal is provided for this purpose. Both
the flecoder and encoder, as well as all flags, are reset by a
LOW on MRST. This function interrupts and overrides all
other control signals. The MRST function can also be sued
during fault recovery routines.
DECODER OPERATION
TRANSCEIVER OPERATION
Figure 3 illustrates the receive mode timing. Decoder detail
timing is shown in Figure 5. A receive cycle, which lasts for 20
clock periods of the 1 MHz DSC OUT, is initiated when the
decoder recognizes a valid sync and two valid Manchester data
bits. TAKE DATA goes LOW at the first HIGH to LOW
(falling edge) transition of DSC OUT, following the second
valid dat bit. COMM/DATA SYNC is updated at the next
rising edge of DSC OUT after TAKE DATA goes LOW.
COM/DATA SYNC remains in its new state until the next
valid word or until DEC RST or MRST goes LOW.
The CT1775N contains a transceiver similar to Aeroflex model
CT3232. When connected to a serial MUX data bus via
transformer and isolation resistors, as shown in Figure 6, the
CT1775N transceiver will fully comply with MIL-STD-1553.
The correct Technitrol part numbers for transformers used in
direct-coupled and transformercoupled operation are shown in
Figure 6.
Transceiver TX INHIBIT and RX STROBE signals are
provided to afford flexible operation. These signals may be
used to disable the transmitter and receiver, respectively.
TAKE DATA remains LOW for 16 periods of DSC OUT,
during which time the 16 serial data bits are shifted into the
first rank receive register. The serial data is simultaneously
available at SERIAL DATA OUT as it is being shifted. At the
completion of decoded data shifting, TAKE DATA goes
HIGH, which transfers the data to the second rank receive
register. This data may be enabled onto the parallel data
highway by LOW on DATA SELECT at any time until the
next rising edge of TAKE DATA.
ENCODER OPERATION
Figure 2 illustrates the transmit mode timing. Encoder detail
timing is shown in Figure 4. The transmit cycle is initiated by a
LOW on ENC ENABLE. The first HIGH to LOW (falling
edge) transition of ESC OUT, when ENC ENABLE is LOW,
starts the cycle which lasts for 20 clock periods of the 1 MHz
ESC OUT. The next LOW to HIGH transition of ESC OUT
strobes the SYNC SELECT line. A HIGH on SYNC SELECT
produces a data sync and a LOW produces a command/status
sync.
At the first rising edge of DSC OUT after TAKE DATA goes
HIGH, VALID WORD is updated. It will go LOW if the
decoded word was valid. VALID WORD will go HIGH at the
start of the next receive cycle, or after 20 microseconds if no
additional words ar received. All output flags are enabled by
VALID WORD, and therefore they are valid only as long as
VALID WORD is LOW.
A LOW to HIGH transition of SEND DATA occurs at the
fourth falling edge of ESC OUT. This indicates the completion
of the sync interval and the start of the serial data interval.
Parallel data must be stable at the second rank transmit register
prior to the rising edge of SEND DATA, which occurs 3
microseconds (minimum) after the HIGH to LOW transition of
ENC ENABLE. LATCH DATA is used to transfer parallel
data to the first rank transmit register. LATCH DATA must be
brought LOW and DATA SELECT brought HIGH prior to the
rising edge of SEND DATA. If SEND DATA is connected
directly to LOAD DATA, it will lock out the second rank
transmit register and serial data shifting into the encoder will
proceed properly.
SCDCT1775 Rev C 7/19/07
5
SYNC
SERIAL DATA OUT
19
0
1
2
15
14
13
12
11
10
3
4
5
6
7
8
9
9
8
7
6
5
4
3
2
1
0
P
10
11
12
13
14
15
16
17
18
19
0
ESE OUT
STROBE
SYNC
START
CYCLE
DATA SENT
STROBE DATA
END CYCLE
DON’T CARE
ENC ENABLE
VALID SYNC
DON’T CARE
SYNC SEL
16µs
SEND DATA
(LOAD DATA)
DON’T CARE
LATCH DATA
VALID DATA
TRI-STATE DATA
DON’T CARE
DATA SELECT
DON’T CARE
FIGURE 2 – TRANSMIT MODE TIMING
SYNC
SERIAL DATA IN
19
0
1
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
P
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
2
SYNC
0
1
2
15
14
13
3
4
5
DSC OUT
START CYCLE
STROBE DATA
TAKE DATA
END CYCLE
TAKE DATA
16µs
COMM / DATA SYNC
PREVIOUS STATE
SERIAL DATA OUT
PREVIOUS STATE
CURRENT SYNC
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
UNDEFINED
15
DATA SELECT 1
CURRENT DATA
TRI-STATE DATA 1
VALID WORD 2
FLAG OUTPUTS 3
BIT STATUS
4
DON’T CARE
PREVIOUS STATE
PREVIOUS STATE
NOT VALID
FLAGS VALID 3
NOT VALID
BIT STATUS VALID 4
NOTES:
1. Parallel data is held continuously in second rank receiver register, and may be enabled onto the tri-state output at any time with a LOW on DATA SELECT.
2. VALID WORD will remainLOW for 20µsec then go HIGH, if a valid sync is not received.
3. FLAG OUTPUTS are valid only when VALID WORD is LOW. Flags are MODE CODE, RT Enable, BROADCAST and VAL CMD WD.
4. BIT STATUS is valid only if wraparound transmit plus receive cycle has been performed. LATCH DATA must be HIGH, and either S/T SELECT or
RX STROBE must be HIGH for the full wraparound cycle duration.
FIGURE 3 – RECEIVE MODE TIMING
SCDCT1775 Rev C 7/19/07
6
19
0
1
2
3
4
ESC OUT
START CYCLE
STROBE SYNC
STROBE DATA
110ns MAX
ENC ENABLE
180ns MIN
190ns MIN
SYNC SELECT
240ns MIN
80ns MAX
SEND DATA
(LOAD DATA)
80ns MIN
DON’T CARE
LATCH DATA
130ns MIN
80ns MIN
DON’T CARE
TRI-STATE DATA
100ns MIN
70ns MIN
DON’T CARE
DATA SELECT
130ns MIN
FIGURE 4 – ENCODER DETAIL TIMING
5
6
7
0
1
2
DSC OUT
100ns MAX
100ns MAX
TAKE DATA
150ns MAX
COMM / DATA SYNC
SERIAL DATA OUT
PREVIOUS
CURRENT SYNC
15
14
CURRENT
0
50ns MIN
DATA SELECT
50ns MAX
TRI-STATE DATA
DON’T CARE
CURRENT DATA
100ns MAX
VALID WORD
60ns MAX
MODE CODE
60ns MAX
RT ENABLE
100ns MAX
BROADCAST
110ns MAX
VAL CMD WD
FIGURE 5 – DECODER DETAIL TIMING
SCDCT1775 Rev C 7/19/07
7
SCDCT1775 Rev C 7/19/07
8
49
68
51
67
3
1.4 : 1
*2
1
3
*2
4
5
6
7
8
4
5
6
7
Q1553-1
1 1:1
8
21V P-P
30V P-P
2
1
1:1.41
3
.75 ZΟ
Q1553-20 .75 ZΟ
4
7V P-P
FIGURE 6 – TYPICAL TRANSFORMER CONNECTIONS
TRANSFORMER COUPLED
55Ω
55Ω
DIRECT COUPLED
* Transformer CT may be left open
Technitrol Part #’s
Q1553-1
&
Q1553-20
RX DATA IN
TX DATA OUT
TX DATA OUT
RX DATA IN
CT1775N
ZΟ = 78Ω
ZΟ = 78Ω
DATA BUS
PIN FUNCTION AND LOADING TABLE
PIN
#
NAME
IIH
(µA)
IIL IOH IOL
(mA) (mA) (mA)
DESCRIPTION
1
GND
Power supply and logic return.
2
+5V OSC/
CLOCK POWER
+5V Power for oscillator and clock driver.
3
NC
No connection.
4
TX INHIBIT
20
-0.4
A LOW on this input inhibits the transmitter.
5
SYNC SELECT
20
-0.4
A LOW on this input results in a transmitted DATA sync.
A HIGH on this input results in a transmitted COMMAND
(or STATUS) sync.
6
SERIAL DATA OUT
-0.4
4.0
Received serial data in NRZ format is available at this
output when TAKE DATA is LOW.
7
ESC OUT
-0.4
4.0
LOW to HIGH transitions on this output when SEND
DATA is HIGH causes the transmit cycle data shifting to
occur.
8
NC
9
COMM / DATA SYNC
10
MRST
11
VALID WORD
-0.4
4.0
A LOW on this output indicates receipt of a valid word.
12
BIT STATUS
-0.4
4.0
A LOW on this output, during wrap around self test only,
indicates that the last word decoded was identical to the
last word encoded.
13
LATCH DATA 1
14
VAL CMD WD
15
BDCST INH
20
-0.4
A LOW on this input inhibits the indication of the
BROADCAST output flag.
16
TMADD1*
20
-0.4
Part of 5 bit hard-wired terminal address input.
17
TMADD3*
20
-0.4
Part of 5 bit herd-wired terminal address input.
18
XTAL
19
CLOCK OUT
-1.0
1.0
Output of oscillator and clock driver (see text).
20
TAKE DATA
-0.4
4.0
A LOW on this output indicates that received data is being
shifted into the first rank register and is available at
SERIAL DATA OUT. A LOW to HIGH transition
transfers the contents of the first rank receiver register to
the second rank register.
No connection.
-.36
40
20
3.6
-0.8
A LOW on this output indicates receipt of a DATA word.
A HIGH indicates receipt of a COMMAND (or STATUS)
word.
A LOW on this input (1 µsec minimum) resets the
decoderto its initialized condition (same function as DEC
RST), resets FAIL-SAFE, and stops and clears the transmit
cycle. This function interrupts and overridesall
othercontrols.
-0.4
A HIGH on this input causes parallel tri-state I/O data on
D8 through D15 to appear at the output of the first rank
transmit register. A LOW locks out the register inputs.
-0.4
4.0
A LOW on this output indicates the receipt of a valid
command word.
A 12 MHz parallel resonant crystal is connected between
this input and ground.
SCDCT1775 Rev C 7/19/07
9
PIN FUNCTION AND LOADING TABLE (con’t)
PIN
#
NAME
IIH
(µA)
20
IIL IOH IOL
(mA) (mA) (mA)
-0.4
DESCRIPTION
21
DEC RST
A LOW on this input (1 µsec minimum) resets the
decoderto its initialized state, resets COMM/DATA SYNC
to a LOW, and resets VALID WORD to a HIGH.
22
DSC OUT
-0.4
4.0
LOW to HIGH transitions on this output when TAKE
DATA is LOW causes causes receive cycle data shifting to
occur.
23
SEND DATA
-0.4
4.0
A HIGH on this output indicates that transmit cycle data
shifting is occuring.
24
CLOCK IN
±1
±.001
25
S/T SELECT
20
-0.4
26
FAIL-SAFE
-0.4
4.0
A HIGH on this output indicates that a transmitted message
has exceeded 768 µsec, and that transmission has been
terminated. FAIL-SAFE is reset by either FIT ENABLE or
MRST.
27
RT ENABLE
-0.4
4.0
A HIGH on this output indicates receipt of a valid
COMMAND word containing the correct 5 bit terminal
address plus address parity. FAIL-SAFE is reset when FIT
ENABLE goes HIGH.
28
MODE CODE
-0.4
4.0
A LOW on this output indicates the reception of a valid
COMMAND word whose sub-address field contains all
ONES or all ZEROES.
29
LATCH DATA 2
20
-0.4
A HIGH on this input causes parallel tri-state I/O data on
D0 through D7 to appear at the output of the first rank
transmit register. A LOW locks out the register inputs.
30
ENCENABLE
20
-0.4
A LOW on this input causes the transmit cycle to start at
the next HIGH to LOW transition of ESC OUT
31
BROADCAST
32
TMADD0*
20
-0.4
LSB of 5-bit hard-wired terminal address input.
33
TMADD2*
20
-0.4
Part of 5-bit hard-wired terminal address input.
34
TMADD4*
20
-0.4
MSB of 5-bit hard-wired terminal address input.
35
TMADDP
20
-0.4
Parity bit of hard-wired terminal address. Hard-wired for
odd parity.
36
CHAN SELECT
100
-2.0
A LOW on this input enables DATA SELECT 1, DATA
SELECT 2, LATCH DATA 1, LATCH DATA 2, and ENC
ENABLE inputs.
37
ODD PARITY
38
D15
12 MHz clock input (20pF load) (see text).
A HIGH on this input enables offline wraparound
selftest.The transceiver is disabled and the encoder output
is connected to the decoder input (see text).
-0.4
20
-0.2
4.0
A HIGH on this output indicates reception of a valid
COMMAND word whose address field contains all ONES,
if BDCST INH is HIGH.
-0.36
3.6
A HIGH on this output indicates a valid check for odd
parity of terminal address plus parity bits, if ENA PAR
CHECK is a LOW.
-12
12
MSB of 16 bit parallel tri-state I/O.
SCDCT1775 Rev C 7/19/07
10
PIN FUNCTION AND LOADING TABLE (con’t)
PIN
#
NAME
IIH
(µA)
IIL IOH IOL
(mA) (mA) (mA)
DESCRIPTION
39
D13
20
-0.2
-12
12
Part of 16 bit parallel tri-state I/O.
40
D11
20
-0.2
-12
12
Part of 16 bit parallel tri-state I/O.
41
D9
20
-0.2
-12
12
Part of 16 bit parallel tri-state I/O.
42
D7
20
-0.2
-12
12
Part of 16 bit parallel tri-state I/O.
43
D5
20
-0.2
-12
12
Part of 16 bit parallel tri-state I/O.
44
D3
20
-0.2
-12
12
Part of 16 bit parallel tri-state I/O.
45
D1
20
-0.2
-12
12
Part of 16 bit parallel tri-state I/O.
46
LOAD DATA 2
20
-0.4
47
+5V
+5V power supply input.
48
+12V
+12Vpower supply input.
49
RX DATA IN
Inverted receiver input.
50
RX STROBE
51
TX DATA OUT
Transmitter output.
52
CASE
Case connection.
53
DATA SELECT 2
20
-0.4
A LOW on this input causes the output of the second rank
receiver register to appear on D0 through D7 of the parallel
tri-state I/O.
54
DATA SELECT 1
20
-0.4
A LOW on this input causes the output of the second rank
receiver register to appear on D8 through D15 of the
parallel tri-state I/O.
55
ENA PAR CHECK
20
-0.4
A LOW on this input enables the function of ODD
PARITY.
56
D14
20
-0.2
-12
12
Part of 16 bit parallel tri-state I/O.
57
D12
20
-0.2
-12
12
Part of 16 bit parallel tri-state I/O.
58
D10
20
-0.2
-12
12
Part of 16 bit parallel tri-state I/O.
59
D8
20
-0.2
-12
12
Part of 16 bit parallel tri-state I/O.
60
D6
20
-0.2
-12
12
Part of 16 bit parallel tri-state I/O.
61
D4
20
-0.2
-12
12
Part of 16 bit parallel tri-state I/O.
62
D2
20
-0.2
-12
12
Part of 16 bit parallel tri-state I/O.
63
D0
20
-0.2
-12
12
LSB of 16 bit parallel tri-state I/O.
64
LOAD DATA 1
20
-0.4
65
GND
40
LOW on this input causes the data of the D0 through D7
outputs of the first rank transmit register to be loaded into
the second rank transmit register. A HIGH locks out the
second rank register inputs.
-1.6
A LOW on this input disables the receiver output.
A LOW on this input causes the data of the D8 through
D15 outputs of the first rank transmit register to be loaded
into the second rank transmit register. A HIGH locks out
the second rank register inputs.
Power supply and logic retum
SCDCT1775 Rev C 7/19/07
11
PIN FUNCTION AND LOADING TABLE (con’t)
PIN
#
NAME
IIH
(µA)
IIL IOH IOL
(mA) (mA) (mA)
DESCRIPTION
66
-12V
-12V power supply input.
67
RX DATA IN
Receiver input.
68
TX DATA OUT
Inverted transmitter output.
NOTES: In the above table, the symbols are defined as follows: *Indicates use of an internal pull-up resistor.
IIH = maximum input HIGH current with VIN = 2.5 volts.
IIL = maximum input LOW current with VIN = 0.4 volts.
IOH = maximum output HIGH current for VOUT = 2.5 volts minimum.
IOL = maximum output LOW current for VOUT = 0.4 volts maximum.
SCDCT1775 Rev C 7/19/07
12
CT1775N PIN OUT DESCRIPTION
PIN
#
1
18
2
19
3
20
4
21
5
22
6
23
7
24
8
25
9
26
10
27
11
28
12
29
13
30
14
31
15
32
16
33
17
34
TX DATA OUT
GND
TX DATA OUT
XTAL
RXSTROBE
+5V OSC/CLOCK POWER
RX DATA IN
CLOCK OUT
RX DATA IN
N/C
-Vc c
TAKE DATA
+Vcc
TX INHIBIT
GND
DECR ST
+5V
SYNC SELECT
LOAD DATA 1
DSC OUT
LOAD DATA 2
SERIAL DATA OUT
D0
SEND DATA
MIL-STD-1553B
D1
ESC OUT
DUMB RTU HYBRID
D2
CLOCK IN
D3
N/C
D4
S/T SELECT
D5
COMM / DATA SYNC
D6
FAIL-SAFE
D7
MRST
D8
RT ENABLE
D9
VALID WORD
D10
MODE CODE
D11
BIT STATUS
D12
LATCH DATA 2
D13
LATCH DATA 1
D14
ENC ENABLE
D15
VAL CMD WD
ENA PAR CHECK
BROADCAST
ODD PARITY
BDCST INH
DATA SELECT 1
TM ADD0
CHAN SELECT
TM ADD 1
DATA SELECT 2
TM ADD 2
TMADDP
TM ADD 3
CASE
TM ADD 4
CT1775N
51
68
50
67
49
66
48
65
47
64
46
63
45
62
44
61
43
60
42
59
41
58
40
57
39
56
38
55
37
54
36
53
35
52
FUNCTION
PIN
#
1
GND
35 TMADDP
2
+5V OSC/
CLOCK PWR
36 CHAN SELECT
3
N/C
37 ODD PARITY
4
TX INHIBIT
38 D15
5
SYNC SELECT
39 D13
6
SERIAL DATA OUT
40 D11
7
ESC OUT
41 D9
8
N/C
42 D7
9
COMM /
DATA SYNC
43 D5
10 MRST
44 D3
11 VALID WORD
45 D1
12 BIT STATUS
46 LOAD DATA 2
13 LATCH DATA 1
47 +5V
14 VAL CMD WD
48 +Vcc
15 BDCST INH
49 RX DATA IN
16 TM ADD 1
50 RXSTROBE
17 TM ADD 3
51 TX DATA OUT
18 XTAL
52 CASE
19 CLOCK OUT
53 DATA SELECT 2
20 TAKE DATA
54 DATA SELECT 1
21 DECR ST
55 ENA PAR CHECK
22 DSC OUT
56 D14
23 SEND DATA
57 D12
24 CLOCK IN
58 D10
25 S/T SELECT
59 D8
26 FAIL-SAFE
60 D6
27 RT ENABLE
61 D4
28 MODE CODE
62 D2
29 LATCH DATA 2
63 D0
30 ENC ENABLE
64 LOAD DATA 1
31 BROADCAST
65 GND
32 TM ADD 0
66 -Vc c
33 TM ADD 2
67 RX DATA IN
34 TM ADD 4
68 TX DATA OUT
FIGURE 3 – PIN CONNECTION DIAGRAM, CT1775N AND PINOUT TABLE
SCDCT1775 Rev C 7/19/07
13
FUNCTION
ORDERING INFORMATION
MODEL NUMBER
CT1775N
SCREENING
Military Temperature, -55°C to +125°C,
Screened to the individual test methods of
MIL-STD-883
PLUG IN PACKAGE OUTLINE
POWER SUPPLY
PACKAGE
+5V, ±12V to ±15V
Plug in
1.850
1.590
Lead 1 & ESD
Designator
1.600
.100
.095
Pin 2
Pin 1
.050 Pin 16
TYP
Pin 17
.190
MAX
Pin 34
Pin 18
.018 DIA
TYP
1.400 1.200
Pin 68
Pin 52
Pin 51
Pin 50
.100
TYP
Pin 35
Pin 36
1.600
.180 MIN
PLAINVIEW, NEW YORK
Toll Free: 800-THE-1553
Fax: 516-694-6715
INTERNATIONAL
Tel: 805-778-9229
Fax: 805-778-1980
NORTHEAST
Tel: 603-888-3975
Fax: 603-888-4585
SE AND MID-ATLANTIC
Tel: 321-951-4164
Fax: 321-951-4254
WEST COAST
Tel: 949-362-2260
Fax: 949-362-2266
CENTRAL
Tel: 719-594-8017
Fax: 719-594-8468
www.aeroflex.com
[email protected]
Aeroflex Microelectronic Solutions reserves the right to
change at any time without notice the specifications, design,
function, or form of its products described herein. All
parameters must be validated for each customer's application
by engineering. No liability is assumed as a result of use of
this product. No patent licenses are implied.
Our passion for performance is defined by three
attributes represented by these three icons:
solution-minded, performance-driven and customer-focused
SCDCT1775 Rev C 7/19/07
14