LV56351HAGEVB_TEST_PROCEDURE - 91 KB

Test Procedure for the LV56351HAGEVB Evaluation Board
The following steps detail the basic test procedure for all these boards:
Suggested equipment:
 Current limited DC Power Supply (e.g. ADVANTEST R6243 DC Voltage Current Source/Monitor) ···· 2pcs
 Digital Multimeter (e.g. ADVANTEST R6452 Digital Multimeter) ············································ 2pcs
 Multifunction Generator (e.g. NF WF1974) ········································································ 1pc
 Electronic Load (e.g. FUJITSU ACCESS LIMITED Electric Load EUL-150αXL) ·························· 1pc
 Oscilloscope (e.g. LeCroy WaveRunner) ············································································ 1pc
PGOOD
2V
SCP
Current limited
DC Power Supply
V1
LDOIN
Hi
Multifunction
Generator
+
-
EN
Digital
Multimeter
Lo
LDOOUT
VCC
IO
Current limited
DC Power Supply
12V
+ Electronic
Load
-
+
-
Digital
Multimeter
GND
Figure 1: Test Setup
Test Procedure:
(1) Connect the test setup as shown in Figure 1
(2) Apply 12Vdc to VCC.
(3) Apply 2Vdc to V1.
(4) Apply Low level (0V) signal to EN.
(5) Check that LDOIN=0[V] and LDOOUT=0[V].
(6) Apply IO(load)=0[A] to LDOOUT.
(7) Apply High level (2V) signal to EN.
(8) Check that LDOIN=17.5[V] and LDOOUT=16.5[V]
(9) Set IO to desired level, 0[mA] – 300[mA], and measure LDOOUT voltage and LDOIN
voltage.
(10) Apply Low level signal to EN.
(11) Turn off IO(load).
(12) Turn off VCC, V1, and EN.
3/13/2014
1
www.onsemi.com