Test Procedure for the LV5636VHGEVB Evaluation Board
The following steps detail the basic test procedure for all these boards:
Suggested equipment:
 Current limited DC Power Supply (e.g. ADVANTEST R6243 DC Voltage Current Source/Monitor) ···· 2pcs
 Digital Multimeter (e.g. ADVANTEST R6452 Digital Multimeter) ············································ 2pcs
 Multifunction Generator (e.g. NF WF1974) ········································································ 2pcs
 Electronic Load (e.g. FUJITSU ACCESS LIMITED Electric Load EUL-150αXL) ·························· 1pc
 Oscilloscope (e.g. LeCroy WaveRunner) ············································································ 1pc
PGOOD
PGDLY
2V
Current limited
DC Power Supply
V1
Hi
Multifunction
Generator
Hi
Multifunction
Generator
LDOIN
CTL
Lo
+
-
EN
Digital
Multimeter
Lo
LDOOUT
VCC
IO
Current limited
DC Power Supply
12V
+ Electronic
Load
-
+
-
Digital
Multimeter
GND
Figure 1: Test Setup
Test Procedure:
(1) Connect the test setup as shown in Figure 1
(2) Apply 12Vdc to VCC.
(3) Apply 2Vdc to V1.
(4) Apply Low level (0V) or High level (2V) signal to CTL.
(5) Apply Low level (0V) signal to EN.
(6) Check that LDOIN=0[V] and LDOOUT=0[V].
(7) Apply IO(load)=0[A] to LDOOUT.
(8) Apply High level (2V) signal to EN.
(9) If CTL state = Low, Check that LDOIN=12.3[V] and LDOOUT=11.7[V]
If CTL state = High, Check that LDOIN=16.5[V] and LDOOUT=15.9[V]
(10) Set IO to desired level, 0[mA] – 410[mA], and measure LDOOUT voltage and LDOIN
voltage.
(11) Change CTL level to High or Low. And Confirm (9) and (10).
(12) Apply Low level signal to EN.
(13) Turn off IO(load).
(14) Turn off VCC, V1, CTL and EN.
3/13/2014
1