PDF Data Sheet Rev. C

14-Output Clock Generator with
Integrated 2.8 GHz VCO
AD9516-0
Data Sheet
FUNCTIONAL BLOCK DIAGRAM
APPLICATIONS
Low jitter, low phase noise clock distribution
10/40/100 Gb/sec networking line cards, including SONET,
Synchronous Ethernet, OTU2/3/4
Forward error correction (G.710)
Clocking high speed ADCs, DACs, DDSs, DDCs, DUCs, MxFEs
High performance wireless transceivers
ATE and high performance instrumentation
GENERAL DESCRIPTION
The AD9516-0 1 provides a multi-output clock distribution
function with subpicosecond jitter performance, along with an
on-chip PLL and VCO. The on-chip VCO tunes from 2.55 GHz
to 2.95 GHz. Optionally, an external VCO/VCXO of up to 2.4 GHz
can be used.
The AD9516-0 emphasizes low jitter and phase noise to
maximize data converter performance, and it can benefit other
applications with demanding phase noise and jitter requirements.
Rev. C
CP
REFIN
REF2
STATUS
MONITOR
PLL
REF1
LF
SWITCHOVER
AND MONITOR
Low phase noise, phase-locked loop (PLL)
On-chip VCO tunes from 2.55 GHz to 2.95 GHz
External VCO/VCXO to 2.4 GHz optional
1 differential or 2 single-ended reference inputs
Reference monitoring capability
Automatic revertive and manual reference
switchover/holdover modes
Accepts LVPECL, LVDS, or CMOS references to 250 MHz
Programmable delays in path to PFD
Digital or analog lock detect, selectable
6 pairs of 1.6 GHz LVPECL outputs
Each output pair shares a 1-to-32 divider with coarse
phase delay
Additive output jitter: 225 fs rms
Channel-to-channel skew paired outputs of <10 ps
4 pairs of 800 MHz LVDS clock outputs
Each output pair shares two cascaded 1-to-32 dividers
with coarse phase delay
Additive output jitter: 275 fs rms
Fine delay adjust (Δt) on each LVDS output
Each LVDS output can be reconfigured as two 250 MHz
CMOS outputs
Automatic synchronization of all outputs on power-up
Manual output synchronization available
64-lead LFCSP
VCO
DIVIDER
AND MUXs
CLK
DIV/Φ
LVPECL
DIV/Φ
LVPECL
DIV/Φ
DIV/Φ
DIV/Φ
DIV/Φ
DIV/Φ
LVPECL
Δt
Δt
Δt
Δt
SERIAL CONTROL PORT
AND
DIGITAL LOGIC
LVDS/CMOS
LVDS/CMOS
OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
OUT8
OUT9
AD9516-0
06419-001
FEATURES
Figure 1.
The AD9516-0 features six LVPECL outputs (in three pairs)
and four LVDS outputs (in two pairs). Each LVDS output can
be reconfigured as two CMOS outputs. The LVPECL outputs
operate to 1.6 GHz, the LVDS outputs operate to 800 MHz, and
the CMOS outputs operate to 250 MHz.
Each pair of outputs has dividers that allow both the divide
ratio and coarse delay (or phase) to be set. The range of division
for the LVPECL outputs is 1 to 32. The LVDS/CMOS outputs
allow a range of divisions up to a maximum of 1024.
The AD9516-0 is available in a 64-lead LFCSP and can be
operated from a single 3.3 V supply. An external VCO, which
requires an extended voltage range, can be accommodated
by connecting the charge pump supply (VCP) to 5 V. A separate
LVPECL power supply can be from 2.5 V to 3.3 V (nominal).
The AD9516-0 is specified for operation over the industrial
range of −40°C to +85°C.
1
AD9516 is used throughout to refer to all the members of the AD9516
family. However, when AD9516-0 is used, it refers to that specific member
of the AD9516 family.
Document Feedback
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700 ©2007–2013 Analog Devices, Inc. All rights reserved.
Technical Support
www.analog.com
AD9516-0
Data Sheet
TABLE OF CONTENTS
Features .............................................................................................. 1
Thermal Resistance .................................................................... 16
Applications ....................................................................................... 1
ESD Caution................................................................................ 16
General Description ......................................................................... 1
Pin Configuration and Function Descriptions........................... 17
Functional Block Diagram .............................................................. 1
Typical Performance Characteristics ........................................... 19
Revision History ............................................................................... 3
Terminology .................................................................................... 25
Specifications..................................................................................... 4
Detailed Block Diagram ................................................................ 26
Power Supply Requirements ....................................................... 4
Theory of Operation ...................................................................... 27
PLL Characteristics ...................................................................... 4
Operational Configurations ...................................................... 27
Clock Inputs .................................................................................. 6
Digital Lock Detect (DLD) ....................................................... 36
Clock Outputs ............................................................................... 6
Clock Distribution ..................................................................... 40
Timing Characteristics ................................................................ 7
Reset Modes ................................................................................ 48
Clock Output Additive Phase Noise (Distribution Only; VCO
Divider Not Used) ........................................................................ 8
Power-Down Modes .................................................................. 49
Serial Control Port ......................................................................... 50
Clock Output Absolute Phase Noise (Internal VCO Used) .... 9
Serial Control Port Pin Descriptions ....................................... 50
Clock Output Absolute Time Jitter (Clock Generation Using
Internal VCO) ............................................................................. 10
General Operation of Serial Control Port ............................... 50
Clock Output Absolute Time Jitter (Clock Cleanup Using
Internal VCO) ............................................................................. 10
MSB/LSB First Transfers ........................................................... 51
The Instruction Word (16 Bits) ................................................ 51
Clock Output Absolute Time Jitter (Clock Generation Using
External VCXO) ......................................................................... 10
Thermal Performance .................................................................... 54
Clock Output Additive Time Jitter (VCO Divider Not Used)
....................................................................................................... 11
Register Map Descriptions ............................................................ 59
Clock Output Additive Time Jitter (VCO Divider Used) ..... 11
Frequency Planning Using the AD9516 .................................. 77
Delay Block Additive Time Jitter .............................................. 12
Using the AD9516 Outputs for ADC Clock Applications .... 77
Serial Control Port ..................................................................... 12
LVPECL Clock Distribution ..................................................... 78
PD, RESET, and SYNC Pins ..................................................... 13
LVDS Clock Distribution .......................................................... 78
LD, STATUS, and REFMON Pins ............................................ 13
CMOS Clock Distribution ........................................................ 79
Power Dissipation ....................................................................... 14
Outline Dimensions ....................................................................... 80
Timing Diagrams ............................................................................ 15
Ordering Guide .......................................................................... 80
Register Map Overview ................................................................. 55
Applications Information .............................................................. 77
Absolute Maximum Ratings .......................................................... 16
Rev. C | Page 2 of 80
Data Sheet
AD9516-0
REVISION HISTORY
2/13—Rev. B to Rev. C
Changes to Register 0x140 to Register 0x143 Default Values;
Table 52 ............................................................................................. 56
Changes to Register 0x140 to Register 0x143 Default Values;
Table 57 ............................................................................................. 71
Updated Outline Dimensions ........................................................80
1/12—Rev. A to Rev. B
Changes to 0x232 Description Column, Table 62 ...................... 76
12/10—Rev. 0 to Rev. A
Changes to Features, Applications, and General Description ..... 1
Change to CPRSET Pin Resistor Parameter in Table 1 ................ 4
Change to P = 2 DM (2/3) Parameter in Table 2 .......................... 5
Changes to Table 4 ............................................................................ 6
Changes to VCP Supply Parameter in Table 17............................. 14
Change to θJA Value and Endnote in Table 19 ............................. 16
Added Exposed Paddle Notation to Figure 6; Changes to
Table 20 ............................................................................................. 17
Added Figure 41; Renumbered Sequentially ............................... 24
Change to High Frequency Clock Distribution—CLK or
External VCO > 1600 MHz Section; Change to Table 22 .......... 27
Changes to Table 24 ........................................................................ 29
Change to Configuration and Register Settings Section............ 31
Change to Phase Frequency Detector (PFD) Section ................ 32
Changes to Charge Pump (CP), On-Chip VCO, PLL
External Loop Filter, and PLL Reference Inputs Sections ......... 33
Change to Figure 47; Added Figure 48 ......................................... 33
Changes to Reference Switchover and VCXO/VCO
Feedback Divider N—P, A, B, R Sections .................................... 34
Changes to Table 28 ........................................................................ 35
Change to Holdover Section .......................................................... 37
Changes to VCO Calibration Section........................................... 39
Changes to Clock Distribution Section........................................ 40
Added Endnote to Table 34 ........................................................... 41
Changes to Channel Dividers—LVDS/CMOS Outputs
Section; Added Endnote to Table 39 ............................................ 43
Changes to Write Section ............................................................... 50
Change to the Instruction Word (16 Bits) Section ..................... 51
Change to Figure 65 ........................................................................ 52
Added Thermal Performance Section .......................................... 54
Changes to Register Address 0x003 in Table 52.......................... 55
Changes to Table 53 ........................................................................ 59
Changes to Table 54 ........................................................................ 60
Changes to Table 55 ........................................................................ 66
Changes to Table 56 ........................................................................ 68
Changes to Table 57 ........................................................................ 71
Changes to Table 58 ........................................................................ 73
Changes to Table 59 ........................................................................ 74
Changes to Table 60 and Table 61 ................................................. 76
Added Frequency Planning Using the AD9516 Section ............ 77
Changes to Figure 71 and Figure 73; Added Figure 72 .............. 78
Changes to LVPECL Clock Distribution and LVDS Clock
Distribution Sections ...................................................................... 78
Updated Outline Dimensions........................................................ 80
4/07—Revision 0: Initial Version
Rev. C | Page 3 of 80
AD9516-0
Data Sheet
SPECIFICATIONS
Typical is given for VS = VS_LVPECL = 3.3 V ± 5%; VS ≤ VCP ≤ 5.25 V; TA = 25°C; RSET = 4.12 kΩ; CPRSET = 5.1 kΩ, unless otherwise noted.
Minimum and maximum values are given over full VS and TA (−40°C to +85°C) variation.
POWER SUPPLY REQUIREMENTS
Table 1.
Parameter
VS
VS_LVPECL
VCP
RSET Pin Resistor
CPRSET Pin Resistor
Min
3.135
2.375
VS
2.7
BYPASS Pin Capacitor
Typ
3.3
4.12
5.1
Max
3.465
VS
5.25
10
220
Unit
V
V
V
kΩ
kΩ
nF
Test Conditions/Comments
3.3 V ± 5%
Nominally 2.5 V to 3.3 V ± 5%
Nominally 3.3 V to 5.0 V ± 5%
Sets internal biasing currents; connect to ground
Sets internal CP current range, nominally 4.8 mA (CP_lsb = 600 µA);
actual current can be calculated by: CP_lsb = 3.06/CPRSET; connect
to ground
Bypass for internal LDO regulator; necessary for LDO stability;
connect to ground
PLL CHARACTERISTICS
Table 2.
Parameter
VCO (ON-CHIP)
Frequency Range
VCO Gain (KVCO)
Tuning Voltage (VT)
Min
2550
0.5
Test Conditions/Comments
2950
MHz
MHz/V
V
See Figure 15
See Figure 10
VCP ≤ VS when using internal VCO; outside of this range, the CP
spurs may increase due to CP up/down mismatch
VCP −
0.5
0
MHz/V
dBc/Hz
dBc/Hz
250
250
MHz
mV p-p
1.35
1.30
1.60
1.50
1.75
1.60
V
V
4.0
4.4
4.8
5.3
5.9
6.4
kΩ
kΩ
250
250
MHz
MHz
V p-p
V
V
µA
pF
20
0
0.8
2.0
0.8
+100
−100
2
PHASE/FREQUENCY DETECTOR (PFD)
PFD Input Frequency
Antibacklash Pulse Width
Unit
1
−105
−123
Input Sensitivity
Self-Bias Voltage, REFIN
Self-Bias Voltage, REFIN
Input Resistance, REFIN
Input Resistance, REFIN
Dual Single-Ended Mode (REF1, REF2)
Input Frequency (AC-Coupled)
Input Frequency (DC-Coupled)
Input Sensitivity (AC-Coupled)
Input Logic High
Input Logic Low
Input Current
Input Capacitance
Max
50
Frequency Pushing (Open-Loop)
Phase Noise at 100 kHz Offset
Phase Noise at 1 MHz Offset
REFERENCE INPUTS
Differential Mode (REFIN, REFIN)
Input Frequency
Typ
100
45
1.3
2.9
6.0
MHz
MHz
ns
ns
ns
f = 2800 MHz
f = 2800 MHz
Differential mode (can accommodate single-ended input by
ac grounding undriven input)
Frequencies below about 1 MHz should be dc-coupled; be careful
to match VCM (self-bias voltage)
PLL figure of merit (FOM) increases with increasing slew rate; see
Figure 14
Self-bias voltage of REFIN 1
Self-bias voltage of REFIN1
Self-biased1
Self-biased1
Two single-ended CMOS-compatible inputs
Slew rate > 50 V/µs
Slew rate > 50 V/µs; CMOS levels
Should not exceed VS p-p
Each pin, REFIN/REFIN (REF1/REF2)
Antibacklash pulse width = 1.3 ns, 2.9 ns
Antibacklash pulse width = 6.0 ns
Register 0x017[1:0] = 01b
Register 0x017[1:0] = 00b; Register 0x017[1:0] = 11b
Register 0x017[1:0] = 10b
Rev. C | Page 4 of 80
Data Sheet
Parameter
CHARGE PUMP (CP)
ICP Sink/Source
High Value
Low Value
Absolute Accuracy
CPRSET Range
ICP High Impedance Mode Leakage
Sink-and-Source Current Matching
ICP vs. CPV
ICP vs. Temperature
PRESCALER (PART OF N DIVIDER)
Prescaler Input Frequency
P = 1 FD
P = 2 FD
P = 3 FD
P = 2 DM (2/3)
P = 4 DM (4/5)
P = 8 DM (8/9)
P = 16 DM (16/17)
P = 32 DM (32/33)
Prescaler Output Frequency
PLL DIVIDER DELAYS
000
001
010
011
100
101
110
111
NOISE CHARACTERISTICS
In-Band Phase Noise of the Charge
Pump/Phase Frequency Detector
(In-Band Is Within the LBW of the PLL)
At 500 kHz PFD Frequency
At 1 MHz PFD Frequency
At 10 MHz PFD Frequency
At 50 MHz PFD Frequency
PLL Figure of Merit (FOM)
AD9516-0
Min
Typ
Max
4.8
0.60
2.5
2.7/10
1
2
1.5
2
mA
mA
%
kΩ
nA
%
%
%
300
600
900
200
1000
2400
3000
3000
300
Off
330
440
550
660
770
880
990
Unit
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
1
2
Programmable
With CPRSET = 5.1 kΩ
CPV = VCP/2
0.5 < CPV < VCP − 0.5 V
0.5 < CPV < VCP − 0.5 V
CPV = VCP/2
See the VCXO/VCO Feedback Divider N—P, A, B, R section
A, B counter input frequency (prescaler input frequency divided
by P)
Register 0x019: R, Bits[5:3]; N, Bits[2:0]; see Table 54
ps
ps
ps
ps
ps
ps
ps
ps
The PLL in-band phase noise floor is estimated by measuring the
in-band phase noise at the output of the VCO and subtracting
20log(N) (where N is the value of the N divider)
−165
−162
−151
−143
−220
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
3.5
7.5
3.5
ns
ns
ns
Reference slew rate > 0.25 V/ns; FOM + 10log (fPFD) is an approximation of the PFD/CP in-band phase noise (in the flat region)
inside the PLL loop bandwidth; when running closed-loop, the
phase noise, as observed at the VCO output, is increased by 20log(N)
Signal available at LD, STATUS, and REFMON pins when selected
by appropriate register settings
Selected by Register 0x017[1:0] and Register 0x018[4]
Register 0x017[1:0] = 00b, 01b,11b; Register 0x018[4] = 1b
Register 0x017[1:0] = 00b, 01b, 11b; Register 0x018[4] = 0b
Register 0x017[1:0] = 10b; Register 0x018[4] = 0b
7
15
11
ns
ns
ns
Register 0x017[1:0] = 00b, 01b, 11b; Register 0x018[4] = 1b
Register 0x017[1:0] = 00b, 01b, 11b; Register 0x018[4] = 0b
Register 0x017[1:0] = 10b; Register 0x018[4] = 0b
PLL DIGITAL LOCK DETECT WINDOW 2
Required to Lock (Coincidence of Edges)
Low Range (ABP 1.3 ns, 2.9 ns)
High Range (ABP 1.3 ns, 2.9 ns)
High Range (ABP 6.0 ns)
To Unlock After Lock (Hysteresis)2
Low Range (ABP 1.3 ns, 2.9 ns)
High Range (ABP 1.3 ns, 2.9 ns)
High Range (ABP 6.0 ns)
Test Conditions/Comments
REFIN and REFIN self-bias points are offset slightly to avoid chatter on an open input condition.
For reliable operation of the digital lock detect, the period of the PFD frequency must be greater than the unlock-after-lock time.
Rev. C | Page 5 of 80
AD9516-0
Data Sheet
CLOCK INPUTS
Table 3.
Parameter
CLOCK INPUTS (CLK, CLK)
Input Frequency
Min
Typ
01
01
Input Sensitivity, Differential
1
Unit
2.4
1.6
GHz
GHz
mV p-p
2
V p-p
1.8
1.8
V
V
mV p-p
kΩ
pF
150
Input Level, Differential
Input Common-Mode Voltage, VCM
Input Common-Mode Range, VCMR
Input Sensitivity, Single-Ended
Input Resistance
Input Capacitance
Max
1.3
1.3
3.9
1.57
150
4.7
2
5.7
Test Conditions/Comments
Differential input
High frequency distribution (VCO divider)
Distribution only (VCO divider bypassed)
Measured at 2.4 GHz; jitter performance is improved
with slew rates > 1 V/ns
Larger voltage swings may turn on the protection
diodes and may degrade jitter performance
Self-biased; enables ac coupling
With 200 mV p-p signal applied; dc-coupled
CLK ac-coupled; CLK ac-bypassed to RF ground
Self-biased
Below about 1 MHz, the input should be dc-coupled. Care should be taken to match VCM.
CLOCK OUTPUTS
Table 4.
Parameter
LVPECL CLOCK OUTPUTS
OUT0, OUT1, OUT2, OUT3, OUT4, OUT5
Output Frequency, Maximum
Output High Voltage (VOH)
Output Low Voltage (VOL)
Output Differential Voltage (VOD)
Min
Typ
2950
VS − 1.12
VS − 2.03
550
247
VS − 0.98
VS − 1.77
790
VS − 0.84
VS − 1.49
980
V
V
mV
800
MHz
454
mV
25
mV
1.24
1.375
25
V
mV
14
24
mA
360
Delta VOD
Output Offset Voltage (VOS)
Delta VOS
Short-Circuit Current (ISA, ISB)
CMOS CLOCK OUTPUTS
OUT6A, OUT6B, OUT7A, OUT7B,
OUT8A, OUT8B, OUT9A, OUT9B
Output Frequency
Output Voltage High (VOH)
Output Voltage Low (VOL)
1.125
Unit
MHz
LVDS CLOCK OUTPUTS
OUT6, OUT7, OUT8, OUT9
Output Frequency
Differential Output Voltage (VOD)
Max
Test Conditions/Comments
Termination = 50 Ω to VS − 2 V
Differential (OUT, OUT)
Using direct to output; see Figure 25 for peak-to –
peak differential amplitude
VOH − VOL for each leg of a differential pair for default
amplitude setting with driver not toggling; see
Figure 25 for variation over frequency
Differential termination 100 Ω at 3.5 mA
Differential (OUT, OUT)
The AD9516 outputs toggle at higher frequencies,
but the output amplitude may not meet the VOD
specification; see Figure 26
VOH − VOL measurement across a differential pair at
the default amplitude setting with output driver
not toggling; see Figure 26 for variation over
frequency
This is the absolute value of the difference between
VOD when the normal output is high vs. when the
complementary output is high
(VOH + VOL)/2 across a differential pair
This is the absolute value of the difference between
VOS when the normal output is high vs. when the
complementary output is high
Output shorted to GND
Single-ended; termination = 10 pF
250
VS − 0.1
0.1
MHz
V
V
Rev. C | Page 6 of 80
See Figure 27
At 1 mA load
At 1 mA load
Data Sheet
AD9516-0
TIMING CHARACTERISTICS
Table 5.
Parameter
LVPECL
Output Rise Time, tRP
Output Fall Time, tFP
PROPAGATION DELAY, tPECL, CLK-TO-LVPECL OUTPUT
High Frequency Clock Distribution Configuration
Clock Distribution Configuration
Variation with Temperature
OUTPUT SKEW, LVPECL OUTPUTS 1
LVPECL Outputs That Share the Same Divider
LVPECL Outputs on Different Dividers
All LVPECL Outputs Across Multiple Parts
LVDS
Output Rise Time, tRL
Output Fall Time, tFL
PROPAGATION DELAY, tLVDS, CLK-TO-LVDS OUTPUT
OUT6, OUT7, OUT8, OUT9
For All Divide Values
Variation with Temperature
OUTPUT SKEW, LVDS OUTPUTS1
LVDS Outputs That Share the Same Divider
LVDS Outputs on Different Dividers
All LVDS Outputs Across Multiple Parts
CMOS
Output Rise Time, tRC
Output Fall Time, tFC
PROPAGATION DELAY, tCMOS, CLK-TO-CMOS OUTPUT
For All Divide Values
Variation with Temperature
OUTPUT SKEW, CMOS OUTPUTS1
CMOS Outputs That Share the Same Divider
All CMOS Outputs on Different Dividers
All CMOS Outputs Across Multiple Parts
DELAY ADJUST 3
Shortest Delay Range 4
Zero Scale
Full Scale
Longest Delay Range4
Zero Scale
Quarter Scale
Full Scale
Delay Variation with Temperature
Short Delay Range5
Zero Scale
Full Scale
Long Delay Range 5
Zero Scale
Full Scale
Min
835
773
1.4
Typ
Max
Unit
70
70
180
180
ps
ps
995
933
0.8
1180
1090
ps
ps
ps/°C
5
13
15
40
220
ps
ps
ps
170
160
350
350
ps
ps
1.8
1.25
2.1
ns
ps/°C
6
25
62
150
430
ps
ps
ps
495
475
1000
985
ps
ps
2.1
2.6
2.6
ns
ps/°C
4
28
66
180
675
ps
ps
ps
Test Conditions/Comments
Termination = 50 Ω to VS − 2 V; level = 810 mV
20% to 80%, measured differentially
80% to 20%, measured differentially
See Figure 43
See Figure 45
Termination = 100 Ω differential; 3.5 mA
20% to 80%, measured differentially 2
20% to 80%, measured differentially2
Delay off on all outputs
Delay off on all outputs
1.6
Termination = open
20% to 80%; CLOAD = 10 pF
80% to 20%; CLOAD = 10 pF
Fine delay off
Fine delay off
50
540
315
880
680
1180
ps
ps
200
1.72
5.7
570
2.31
8.0
950
2.89
10.1
ps
ns
ns
0.23
−0.02
ps/°C
ps/°C
0.3
0.24
ps/°C
ps/°C
LVDS and CMOS
Register 0xA1 (0xA4, 0xA7, 0xAA), Bits[5:0] = 101111b
Register 0xA2 (0xA5, 0xA8, 0xAB), Bits[5:0] = 000000b
Register 0xA2 (0xA5, 0xA8, 0xAB), Bits[5:0] = 101111b
Register 0xA1 (0xA4, 0xA7, 0xAA), Bits[5:0] = 000000b
Register 0xA2 (0xA5, 0xA8, 0xAB), Bits[5:0] = 000000b
Register 0xA2 (0xA5, 0xA8, 0xAB), Bits[5:0] = 001100b
Register 0xA2 (0xA5, 0xA8, 0xAB), Bits[5:0] = 101111b
This is the difference between any two similar delay paths while operating at the same voltage and temperature.
Corresponding CMOS drivers set to A for noninverting and B for inverting.
3
The maximum delay that can be used is a little less than one-half the period of the clock. A longer delay disables the output.
4
Incremental delay; does not include propagation delay.
5
All delays between zero scale and full scale can be estimated by linear interpolation.
1
2
Rev. C | Page 7 of 80
AD9516-0
Data Sheet
CLOCK OUTPUT ADDITIVE PHASE NOISE (DISTRIBUTION ONLY; VCO DIVIDER NOT USED)
Table 6.
Parameter
CLK-TO-LVPECL ADDITIVE PHASE NOISE
CLK = 1 GHz, Output = 1 GHz
Divider = 1
At 10 Hz Offset
At 100 Hz Offset
At 1 kHz Offset
At 10 kHz Offset
At 100 kHz Offset
At 1 MHz Offset
At 10 MHz Offset
At 100 MHz Offset
CLK = 1 GHz, Output = 200 MHz
Divider = 5
At 10 Hz Offset
At 100 Hz Offset
At 1 kHz Offset
At 10 kHz Offset
At 100 kHz Offset
At 1 MHz Offset
>10 MHz Offset
CLK-TO-LVDS ADDITIVE PHASE NOISE
CLK = 1.6 GHz, Output = 800 MHz
Divider = 2
At 10 Hz Offset
At 100 Hz Offset
At 1 kHz Offset
At 10 kHz Offset
At 100 kHz Offset
At 1 MHz Offset
At 10 MHz Offset
At 100 MHz Offset
CLK = 1.6 GHz, Output = 400 MHz
Divider = 4
At 10 Hz Offset
At 100 Hz Offset
At 1 kHz Offset
At 10 kHz Offset
At 100 kHz Offset
At 1 MHz Offset
>10 MHz Offset
CLK-TO-CMOS ADDITIVE PHASE NOISE
CLK = 1 GHz, Output = 250 MHz
Divider = 4
At 10 Hz Offset
At 100 Hz Offset
At 1 kHz Offset
At 10 kHz Offset
At 100 kHz Offset
At 1 MHz Offset
>10 MHz Offset
Min
Typ
−109
−118
−130
−139
−144
−146
−147
−149
Max
Unit
Test Conditions/Comments
Distribution section only; does not include PLL and VCO
Input slew rate > 1 V/ns
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Input slew rate > 1 V/ns
−120
−126
−139
−150
−155
−157
−157
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Distribution section only; does not include PLL and VCO
Input slew rate > 1 V/ns
−103
−110
−120
−127
−133
−138
−147
−149
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Input slew rate > 1 V/ns
−114
−122
−132
−140
−146
−150
−155
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Distribution section only; does not include PLL and VCO
Input slew rate > 1 V/ns
−110
−120
−127
−136
−144
−147
−154
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Rev. C | Page 8 of 80
Data Sheet
Parameter
CLK = 1 GHz, Output = 50 MHz
Divider = 20
At 10 Hz Offset
At 100 Hz Offset
At 1 kHz Offset
At 10 kHz Offset
At 100 kHz Offset
At 1 MHz Offset
>10 MHz Offset
AD9516-0
Min
Typ
Max
−124
−134
−142
−151
−157
−160
−163
Unit
Test Conditions/Comments
Input slew rate > 1 V/ns
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
CLOCK OUTPUT ABSOLUTE PHASE NOISE (INTERNAL VCO USED)
Table 7.
Parameter
LVPECL ABSOLUTE PHASE NOISE
VCO = 2.95 GHz; Output = 2.95 GHz
At 1 kHz Offset
At 10 kHz Offset
At 100 kHz Offset
At 1 MHz Offset
At 10 MHz Offset
At 40 MHz Offset
VCO = 2.75 GHz; Output = 2.75 GHz
At 1 kHz Offset
At 10 kHz Offset
At 100 kHz Offset
At 1 MHz Offset
At 10 MHz Offset
At 40 MHz Offset
VCO = 2.55 GHz; Output = 2.55 GHz
At 1 kHz Offset
At 10 kHz Offset
At 100 kHz Offset
At 1 MHz Offset
At 10 MHz Offset
At 40 MHz Offset
Min
Typ
Max
Unit
−47
−78
−104
−122
−140
−146
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
−49
−79
−105
−123
−141
−146
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
−51
−80
−106
−125
−142
−146
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Rev. C | Page 9 of 80
Test Conditions/Comments
Internal VCO; direct to LVPECL output
AD9516-0
Data Sheet
CLOCK OUTPUT ABSOLUTE TIME JITTER (CLOCK GENERATION USING INTERNAL VCO)
Table 8.
Parameter
LVPECL OUTPUT ABSOLUTE TIME JITTER
Min
VCO = 2.95 GHz; LVPECL = 491.52 MHz; PLL LBW = 75 kHz
Typ
Max
148
342
212
320
184
304
221
345
210
334
VCO = 2.95 GHz; LVPECL = 122.88 MHz; PLL LBW = 75 kHz
VCO = 2.70 GHz; LVPECL = 122.88 MHz; PLL LBW = 187 kHz
VCO = 2.70 GHz; LVPECL = 61.44 MHz; PLL LBW = 187 kHz
VCO = 2.58 GHz; LVPECL = 61.44 MHz; PLL LBW = 75 kHz
Unit
fs rms
fs rms
fs rms
fs rms
fs rms
fs rms
fs rms
fs rms
fs rms
fs rms
Test Conditions/Comments
Application example based on a typical
setup where the reference source is clean,
so a wider PLL loop bandwidth is used;
reference = 15.36 MHz; R = 1
Integration BW = 200 kHz to 10 MHz
Integration BW = 12 kHz to 20 MHz
Integration BW = 200 kHz to 10 MHz
Integration BW = 12 kHz to 20 MHz
Integration BW = 200 kHz to 10 MHz
Integration BW = 12 kHz to 20 MHz
Integration BW = 200 kHz to 10 MHz
Integration BW = 12 kHz to 20 MHz
Integration BW = 200 kHz to 10 MHz
Integration BW = 12 kHz to 20 MHz
CLOCK OUTPUT ABSOLUTE TIME JITTER (CLOCK CLEANUP USING INTERNAL VCO)
Table 9.
Parameter
LVPECL OUTPUT ABSOLUTE TIME JITTER
Min
VCO = 2.80 GHz; LVPECL = 155.52 MHz; PLL LBW = 12.8 kHz
VCO = 2.95 GHz; LVPECL = 77.76 MHz; PLL LBW = 12.8 kHz
Typ
Max
513
544
Unit
fs rms
fs rms
Test Conditions/Comments
Application example based on a typical
setup where the reference source is jittery,
so a narrower PLL loop bandwidth is used;
reference = 19.44 MHz; R = 1
Integration BW = 12 kHz to 20 MHz
Integration BW = 12 kHz to 20 MHz
CLOCK OUTPUT ABSOLUTE TIME JITTER (CLOCK GENERATION USING EXTERNAL VCXO)
Table 10.
Parameter
LVPECL OUTPUT ABSOLUTE TIME JITTER
LVPECL = 245.76 MHz; PLL LBW = 125 Hz
LVPECL = 122.88 MHz; PLL LBW = 125 Hz
LVPECL = 61.44 MHz; PLL LBW = 125 Hz
Min
Typ
Max
54
77
109
79
114
163
124
176
259
Rev. C | Page 10 of 80
Unit
fs rms
fs rms
fs rms
fs rms
fs rms
fs rms
fs rms
fs rms
fs rms
Test Conditions/Comments
Application example based on a typical
setup using an external 245.76 MHz VCXO
(Toyocom TCO-2112); reference = 15.36 MHz;
R=1
Integration BW = 200 kHz to 5 MHz
Integration BW = 200 kHz to 10 MHz
Integration BW = 12 kHz to 20 MHz
Integration BW = 200 kHz to 5 MHz
Integration BW = 200 kHz to 10 MHz
Integration BW = 12 kHz to 20 MHz
Integration BW = 200 kHz to 5 MHz
Integration BW = 200 kHz to 10 MHz
Integration BW = 12 kHz to 20 MHz
Data Sheet
AD9516-0
CLOCK OUTPUT ADDITIVE TIME JITTER (VCO DIVIDER NOT USED)
Table 11.
Parameter
LVPECL OUTPUT ADDITIVE TIME JITTER
Min
Typ
Max
Unit
CLK = 622.08 MHz; LVPECL = 622.08 MHz; Divider = 1
CLK = 622.08 MHz; LVPECL = 155.52 MHz; Divider = 4
CLK = 1.6 GHz; LVPECL = 100 MHz; Divider = 16
40
80
215
fs rms
fs rms
fs rms
CLK = 500 MHz; LVPECL = 100 MHz; Divider = 5
245
fs rms
85
fs rms
113
280
fs rms
fs rms
365
fs rms
LVDS OUTPUT ADDITIVE TIME JITTER
CLK = 1.6 GHz; LVDS = 800 MHz; Divider = 2;
VCO Divider Not Used
CLK = 1 GHz; LVDS = 200 MHz; Divider = 5
CLK = 1.6 GHz; LVDS= 100 MHz; Divider = 16
CMOS OUTPUT ADDITIVE TIME JITTER
CLK = 1.6 GHz; CMOS = 100 MHz; Divider = 16
Test Conditions/Comments
Distribution section only; does not include
PLL and VCO; uses rising edge of clock signal
BW = 12 kHz to 20 MHz
BW = 12 kHz to 20 MHz
Calculated from SNR of ADC method; DCC
not used for even divides
Calculated from SNR of ADC method;
DCC on
Distribution section only; does not include
PLL and VCO; uses rising edge of clock signal
BW = 12 kHz to 20 MHz
BW = 12 kHz to 20 MHz
Calculated from SNR of ADC method; DCC
not used for even divides
Distribution section only; does not include
PLL and VCO; uses rising edge of clock signal
Calculated from SNR of ADC method; DCC
not used for even divides
CLOCK OUTPUT ADDITIVE TIME JITTER (VCO DIVIDER USED)
Table 12.
Parameter
LVPECL OUTPUT ADDITIVE TIME JITTER
Min
Typ
CLK = 2.4 GHz; VCO DIV = 2; LVPECL = 100 MHz;
Divider = 12; Duty-Cycle Correction = Off
LVDS OUTPUT ADDITIVE TIME JITTER
210
CLK = 2.4 GHz; VCO DIV = 2; LVDS = 100 MHz;
Divider = 12; Duty-Cycle Correction = Off
CMOS OUTPUT ADDITIVE TIME JITTER
285
CLK = 2.4 GHz; VCO DIV = 2; CMOS = 100 MHz;
Divider = 12; Duty-Cycle Correction = Off
Max
350
Rev. C | Page 11 of 80
Unit
fs rms
Test Conditions/Comments
Distribution section only; does not include
PLL and VCO; uses rising edge of clock signal
Calculated from SNR of ADC method
fs rms
Distribution section only; does not include
PLL and VCO; uses rising edge of clock signal
Calculated from SNR of ADC method
fs rms
Distribution section only; does not include
PLL and VCO; uses rising edge of clock signal
Calculated from SNR of ADC method
AD9516-0
Data Sheet
DELAY BLOCK ADDITIVE TIME JITTER
Table 13.
Parameter
DELAY BLOCK ADDITIVE TIME JITTER 1
100 MHz Output
Delay (1600 µA, 0x1C) Fine Adj. 000000
Delay (1600 µA, 0x1C) Fine Adj. 101111
Delay (800 µA, 0x1C) Fine Adj. 000000
Delay (800 µA, 0x1C) Fine Adj. 101111
Delay (800 µA, 0x4C) Fine Adj. 000000
Delay (800 µA, 0x4C) Fine Adj. 101111
Delay (400 µA, 0x4C) Fine Adj. 000000
Delay (400 µA, 0x4C) Fine Adj. 101111
Delay (200 µA, 0x1C) Fine Adj. 000000
Delay (200 µA, 0x1C) Fine Adj. 101111
Delay (200 µA, 0x4C) Fine Adj. 000000
Delay (200 µA, 0x4C) Fine Adj. 101111
1
Min
Typ
Max
0.54
0.60
0.65
0.85
0.79
1.2
1.2
2.0
1.3
2.5
1.9
3.8
Unit
Test Conditions/Comments
Incremental additive jitter
ps rms
ps rms
ps rms
ps rms
ps rms
ps rms
ps rms
ps rms
ps rms
ps rms
ps rms
ps rms
This value is incremental. That is, it is in addition to the jitter of the LVDS or CMOS output without the delay. To estimate the total jitter, the LVDS or CMOS output jitter
should be added to this value using the root sum of the squares (RSS) method.
SERIAL CONTROL PORT
Table 14.
Parameter
CS (INPUT)
Input Logic 1 Voltage
Input Logic 0 Voltage
Input Logic 1 Current
Input Logic 0 Current
Input Capacitance
SCLK (INPUT)
Input Logic 1 Voltage
Input Logic 0 Voltage
Input Logic 1 Current
Input Logic 0 Current
Input Capacitance
SDIO (WHEN INPUT)
Input Logic 1 Voltage
Input Logic 0 Voltage
Input Logic 1 Current
Input Logic 0 Current
Input Capacitance
SDIO, SDO (OUTPUTS)
Output Logic 1 Voltage
Output Logic 0 Voltage
TIMING
Clock Rate (SCLK, 1/tSCLK)
Pulse Width High, tHIGH
Pulse Width Low, tLOW
SDIO to SCLK Setup, tDS
SCLK to SDIO Hold, tDH
SCLK to Valid SDIO and SDO, tDV
CS to SCLK Setup and Hold, tS, tH
CS Minimum Pulse Width High, tPWH
Min
Typ
Max
2.0
0.8
3
110
2
Unit
Test Conditions/Comments
CS has an internal 30 kΩ pull-up resistor
V
V
µA
µA
pF
SCLK has an internal 30 kΩ pull-down resistor
2.0
0.8
110
1
2
2.0
0.8
10
20
2
2.7
0.4
25
16
16
2
1.1
8
2
3
V
V
µA
µA
pF
V
V
nA
nA
pF
V
V
MHz
ns
ns
ns
ns
ns
ns
ns
Rev. C | Page 12 of 80
Data Sheet
AD9516-0
PD, RESET, AND SYNC PINS
Table 15.
Parameter
INPUT CHARACTERISTICS
Min
Logic 1 Voltage
Logic 0 Voltage
Logic 1 Current
Logic 0 Current
Capacitance
RESET TIMING
Pulse Width Low
SYNC TIMING
Pulse Width Low
2.0
Typ
Max
0.8
110
1
2
Unit
Test Conditions/Comments
These pins each have a 30 kΩ internal pull-up
resistor
V
V
µA
µA
pF
50
ns
1.5
High speed
clock cycles
High speed clock is CLK input signal
Max
Unit
Test Conditions/Comments
When selected as a digital output (CMOS); there
are other modes in which these pins are not
CMOS digital outputs; see Table 54, Register
0x017, Register 0x01A, and Register 0x01B
0.4
100
V
V
MHz
3
pF
On-chip capacitance; used to calculate RC time
constant for analog lock detect readback; use a
pull-up resistor
1.02
MHz
8
kHz
Frequency above which the monitor always
indicates the presence of the reference
Frequency above which the monitor always
indicates the presence of the reference
LD, STATUS, AND REFMON PINS
Table 16.
Parameter
OUTPUT CHARACTERISTICS
Min
Output Voltage High (VOH)
Output Voltage Low (VOL)
MAXIMUM TOGGLE RATE
2.7
ANALOG LOCK DETECT
Capacitance
REF1, REF2, AND VCO FREQUENCY STATUS MONITOR
Normal Range
Extended Range (REF1 and REF2 Only)
LD PIN COMPARATOR
Trip Point
Hysteresis
Typ
1.6
260
V
mV
Rev. C | Page 13 of 80
Applies when mux is set to any divider or
counter output, or PFD up/down pulse; also
applies in analog lock detect mode; usually
debug mode only; beware that spurs may
couple to output when any of these pins are
toggling
AD9516-0
Data Sheet
POWER DISSIPATION
Table 17.
Parameter
POWER DISSIPATION, CHIP
Power-On Default
Typ
Max
Unit
Test Conditions/Comments
1.0
1.2
W
Full Operation; CMOS Outputs at 229 MHz
1.6
2.2
W
Full Operation; LVDS Outputs at 200 MHz
1.6
2.3
W
PD Power-Down
75
185
mW
PD Power-Down, Maximum Sleep
31
No clock; no programming; default register values;
does not include power dissipated in external resistors
PLL on; internal VCO = 2750 MHz; VCO divider = 2;
all channel dividers on; six LVPECL outputs at 687.5 MHz;
eight CMOS outputs (10 pF load) at 229 MHz; all fine delay on,
maximum current; does not include power dissipated in
external resistors
PLL on; internal VCO = 2800 MHz, VCO divider = 2;
all channel dividers on; six LVPECL outputs at 700 MHz;
four LVDS outputs at 200 MHz; all fine delay on, maximum
current; does not include power dissipated in external resistors
PD pin pulled low; does not include power dissipated in
terminations
PD pin pulled low; PLL power-down, Register 0x010[1:0] = 01b;
SYNC power-down, Register 0x230[2] = 1b; REF for distribution
power-down, Register 0x230[1] = 1b
PLL operating; typical closed-loop configuration
Power delta when a function is enabled/disabled
VCO divider bypassed
All references off to differential reference enabled
All references off to REF1 or REF2 enabled; differential
reference not enabled
CLK input selected to VCO selected
PLL off to PLL on, normal operation; no reference enabled
Divider bypassed to divide-by-2 to divide-by-32
No LVPECL output on to one LVPECL output on, independent
of frequency
Second LVPECL output turned on, same channel
No LVDS output on to one LVDS output on; see Figure 8 for
dependence on output frequency
Second LVDS output turned on, same channel
Static; no CMOS output on to one CMOS output on;
see Figure 9 for variation over output frequency
Static; second CMOS output, same pair, turned on
Static; first output, second pair, turned on
Delay block off to delay block enabled; maximum current setting
VCP Supply
POWER DELTAS, INDIVIDUAL FUNCTIONS
VCO Divider
REFIN (Differential)
REF1, REF2 (Single-Ended)
Min
4
mW
4.8
mW
30
20
4
mW
mW
mW
VCO
PLL
Channel Divider
LVPECL Channel (Divider Plus Output Driver)
70
75
30
160
mW
mW
mW
mW
LVPECL Driver
LVDS Channel (Divider Plus Output Driver)
90
120
mW
mW
LVDS Driver
CMOS Channel (Divider Plus Output Driver)
50
100
mW
mW
CMOS Driver (Second in Pair)
CMOS Driver (First in Second Pair)
Fine Delay Block
0
30
50
mW
mW
mW
Rev. C | Page 14 of 80
Data Sheet
AD9516-0
TIMING DIAGRAMS
tCLK
CLK
DIFFERENTIAL
80%
tPECL
LVDS
06419-060
tCMOS
tRL
tFL
06419-062
20%
tLVDS
Figure 4. LVDS Timing, Differential
Figure 2. CLK/CLK to Clock Output Timing, DIV = 1
DIFFERENTIAL
SINGLE-ENDED
80%
80%
LVPECL
CMOS
10pF LOAD
20%
tFP
tRC
tFC
Figure 5. CMOS Timing, Single-Ended, 10 pF Load
Figure 3. LVPECL Timing, Differential
Rev. C | Page 15 of 80
06419-063
tRP
06419-061
20%
AD9516-0
Data Sheet
ABSOLUTE MAXIMUM RATINGS
Table 18.
Parameter
VS, VS_LVPECL to GND
VCP to GND
REFIN, REFIN to GND
REFIN to REFIN
RSET to GND
CPRSET to GND
CLK, CLK to GND
CLK to CLK
SCLK, SDIO, SDO, CS to GND
OUT0, OUT0, OUT1, OUT1, OUT2, OUT2,
OUT3, OUT3, OUT4, OUT4, OUT5, OUT5,
OUT6, OUT6, OUT7, OUT7, OUT8, OUT8,
OUT9, OUT9 to GND
SYNC to GND
REFMON, STATUS, LD to GND
Junction Temperature1
Storage Temperature Range
Lead Temperature (10 sec)
1
Rating
−0.3 V to +3.6 V
−0.3 V to+5.8 V
−0.3 V to VS + 0.3 V
−3.3 V to +3.3 V
−0.3 V to VS + 0.3 V
−0.3 V to VS + 0.3 V
−0.3 V to VS + 0.3 V
−1.2 V to +1.2 V
−0.3 V to VS + 0.3 V
−0.3 V to VS + 0.3 V
−0.3 V to VS + 0.3 V
−0.3 V to VS + 0.3 V
150°C
−65°C to +150°C
300°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
THERMAL RESISTANCE
Table 19.
Package Type1
64-Lead LFCSP
1
θJA
22
Unit
°C/W
Thermal impedance measurements were taken on a 4-layer board in still air
in accordance with EIA/JESD51-2.
ESD CAUTION
See Table 19 for θJA.
Rev. C | Page 16 of 80
Data Sheet
AD9516-0
PIN 1
INDICATOR
AD9516-0
TOP VIEW
(Not to Scale)
LVPECL LVPECL
LVDS/CMOS
w/FINE DELAY ADJUST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
LVDS/CMOS
w/FINE DELAY ADJUST
LVPECL LVPECL
VS
REFMON
LD
VCP
CP
STATUS
REF_SEL
SYNC
LF
BYPASS
VS
VS
CLK
CLK
NC
SCLK
LVPECL LVPECL
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
REFIN (REF1)
REFIN (REF2)
CPRSET
VS
VS
GND
RSET
VS
OUT0
OUT0
VS_LVPECL
OUT1
OUT1
VS
VS
VS
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
OUT6 (OUT6A)
OUT6 (OUT6B)
OUT7 (OUT7A)
OUT7 (OUT7B)
GND
OUT2
OUT2
VS_LVPECL
OUT3
OUT3
VS
GND
OUT9 (OUT9B)
OUT9 (OUT9A)
OUT8 (OUT8B)
OUT8 (OUT8A)
NOTES
1. THE EXTERNAL PADDLE ON THE BOTTOM OF THE PACKAGE MUST BE
CONNECTED TO GROUND FOR PROPER OPERATION.
2. NC = NO CONNECT. DO NOT CONNECT TO THIS PIN.
06419-003
CS
NC
NC
NC
SDO
SDIO
RESET
PD
OUT4
OUT4
VS_LVPECL
OUT5
OUT5
VS
VS
VS
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
NC = NO CONNECT
Figure 6. Pin Configuration
Table 20. Pin Function Descriptions
Input/
Output
I
Pin Type
Power
Mnemonic
VS
Description
3.3 V Power Pins.
I
3.3 V CMOS
REFMON
3
O
3.3 V CMOS
LD
4
5
6
7
I
O
O
I
Power
3.3 V CMOS
3.3 V CMOS
3.3 V CMOS
VCP
CP
STATUS
REF_SEL
8
I
3.3 V CMOS
SYNC
9
I
Loop filter
LF
10
13
O
I
BYPASS
CLK
14
I
Loop filter
Differential
clock input
Differential
clock input
Reference Monitor (Output). This pin has multiple selectable outputs; see Table 54,
Register 0x01B.
Lock Detect (Output). This pin has multiple selectable outputs; see Table 54,
Register 0x1A.
Power Supply for Charge Pump (CP); VS ≤ VCP ≤ 5.0 V.
Charge Pump (Output). Connects to external loop filter.
Status (Output). This pin has multiple selectable outputs; see Table 54, Register 0x017.
Reference Select. Selects REF1 (low) or REF2 (high). This pin has an internal 30 kΩ
pull-down resistor.
Manual Synchronizations and Manual Holdover. This pin initiates a manual
synchronization and is also used for manual holdover. Active low. This pin has an
internal 30 kΩ pull-up resistor.
Loop Filter (Input). Connects to VCO control voltage node internally. This pin has
31 pF of internal capacitance to ground, which may influence the loop filter design
for large (>500 kHz) loop bandwidths.
This pin is for bypassing the LDO to ground with a capacitor.
Along with CLK, this is the differential input for the clock distribution section.
CLK
Along with CLK, this is the differential input for the clock distribution section.
Pin No.
1, 11, 12, 30,
31, 32, 38,
49, 50, 51,
57, 60, 61
2
Rev. C | Page 17 of 80
AD9516-0
Data Sheet
Input/
Output
N/A
I
I
Pin Type
NC
3.3 V CMOS
3.3 V CMOS
Mnemonic
NC
SCLK
CS
21
22
23
24
27, 41, 54
37, 44, 59,
EPAD
56
55
53
52
43
42
40
39
25
26
28
29
48
O
I/O
I
I
I
N/A
3.3 V CMOS
3.3 V CMOS
3.3 V CMOS
3.3 V CMOS
Power
GND
SDO
SDIO
RESET
PD
VS_LVPECL
GND
O
O
O
O
O
O
O
O
O
O
O
O
O
47
O
46
O
45
O
33
O
34
O
35
O
36
O
58
O
OUT0
OUT0
OUT1
OUT1
OUT2
OUT2
OUT3
OUT3
OUT4
OUT4
OUT5
OUT5
OUT6
(OUT6A)
OUT6
(OUT6B)
OUT7
(OUT7A)
OUT7
(OUT7B)
OUT8
(OUT8A)
OUT8
(OUT8B)
OUT9
(OUT9A)
OUT9
(OUT9B)
RSET
62
O
CPRSET
A resistor connected to this pin sets the CP current range. Nominal value = 5.1 kΩ.
63
I
64
I
LVPECL
LVPECL
LVPECL
LVPECL
LVPECL
LVPECL
LVPECL
LVPECL
LVPECL
LVPECL
LVPECL
LVPECL
LVDS or
CMOS
LVDS or
CMOS
LVDS or
CMOS
LVDS or
CMOS
LVDS or
CMOS
LVDS or
CMOS
LVDS or
CMOS
LVDS or
CMOS
Current set
resistor
Current set
resistor
Reference
input
Reference
input
Description
No Connect. Do not connect to this pin.
Serial Control Port Data Clock Signal.
Serial Control Port Chip Select, Active Low. This pin has an internal 30 kΩ pull-up
resistor.
Serial Control Port Unidirectional Serial Data Out.
Serial Control Port Bidirectional Serial Data In/Out.
Chip Reset, Active Low. This pin has an internal 30 kΩ pull-up resistor.
Chip Power-Down, Active Low. This pin has an internal 30 kΩ pull-up resistor.
Extended Voltage 2.5 V to 3.3 V LVPECL Power Pins.
Ground Pins, Including External Paddle (EPAD). The external paddle on the bottom of
the package must be connected to ground for proper operation.
LVPECL Output; One Side of a Differential LVPECL Output.
LVPECL Output; One Side of a Differential LVPECL Output.
LVPECL Output; One Side of a Differential LVPECL Output.
LVPECL Output; One Side of a Differential LVPECL Output.
LVPECL Output; One Side of a Differential LVPECL Output.
LVPECL Output; One Side of a Differential LVPECL Output.
LVPECL Output; One Side of a Differential LVPECL Output.
LVPECL Output; One Side of a Differential LVPECL Output.
LVPECL Output; One Side of a Differential LVPECL Output.
LVPECL Output; One Side of a Differential LVPECL Output.
LVPECL Output; One Side of a Differential LVPECL Output.
LVPECL Output; One Side of a Differential LVPECL Output.
LVDS/CMOS Output; One Side of a Differential LVDS Output, or a Single-Ended CMOS
Output.
LVDS/CMOS Output; One Side of a Differential LVDS Output, or a Single-Ended CMOS
Output.
LVDS/CMOS Output; One Side of a Differential LVDS Output, or a Single-Ended CMOS
Output.
LVDS/CMOS Output; One Side of a Differential LVDS Output, or a Single-Ended CMOS
Output.
LVDS/CMOS Output; One Side of a Differential LVDS Output, or a Single-Ended CMOS
Output.
LVDS/CMOS Output; One Side of a Differential LVDS Output, or a Single-Ended CMOS
Output.
LVDS/CMOS Output; One Side of a Differential LVDS Output, or a Single-Ended CMOS
Output.
LVDS/CMOS Output; One Side of a Differential LVDS Output, or a Single-Ended CMOS
Output.
A resistor connected to this pin sets internal bias currents. Nominal value = 4.12 kΩ.
REFIN
(REF2)
REFIN
(REF1)
Along with REFIN, this pin is the differential input for the PLL reference.
Alternatively, this pin is a single-ended input for REF2.
Along with REFIN, this pin is the differential input for the PLL reference.
Alternatively, this pin is a single-ended input for REF1.
Pin No.
15, 18, 19, 20
16
17
Rev. C | Page 18 of 80
Data Sheet
AD9516-0
TYPICAL PERFORMANCE CHARACTERISTICS
300
65
3 CHANNELS - 6 LVPECL
280
60
260
KVCO (MHz/V)
CURRENT (mA)
240
220
200
3 CHANNELS - 3 LVPECL
180
160
55
50
2 CHANNELS - 2 LVPECL
140
45
1 CHANNEL - 1 LVPECL
0
500
1000
1500
2000
2500
3000
FREQUENCY (MHz)
40
2.55
06419-007
100
2.65
Figure 7. Current vs. Frequency, Direct to Output, LVPECL Outputs
2.85
2.95
Figure 10. VCO KVCO vs. Frequency
180
5.0
4.5
2 CHANNELS - 4 LVDS
CURRENT FROM CP PIN (mA)
160
CURRENT (mA)
2.75
VCO FREQUENCY (GHz)
06419-010
120
140
2 CHANNELS - 2 LVDS
120
100
4.0
3.5
PUMP DOWN
PUMP UP
3.0
2.5
2.0
1.5
1.0
0.5
1 CHANNEL - 1 LVDS
200
400
600
800
FREQUENCY (MHz)
0
1.0
1.5
2.0
2.5
3.0
VOLTAGE ON CP PIN (V)
Figure 8. Current vs. Frequency—LVDS Outputs
(Includes Clock Distribution Current Draw)
Figure 11. Charge Pump Characteristics at VCP = 3.3 V
5.0
240
4.5
CURRENT FROM CP PIN (mA)
220
200
2 CHANNEL - 8 CMOS
180
2 CHANNEL - 2 CMOS
160
140
120
1 CHANNEL - 2 CMOS
100
4.0
3.5
PUMP DOWN
PUMP UP
3.0
2.5
2.0
1.5
1.0
0.5
80
0
50
100
150
200
FREQUENCY (MHz)
250
Figure 9. Current vs. Frequency—CMOS Outputs
0
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
VOLTAGE ON CP PIN (V)
Figure 12. Charge Pump Characteristics at VCP = 5.0 V
Rev. C | Page 19 of 80
5.0
06419-012
1 CHANNEL - 1 CMOS
06419-009
CURRENT (mA)
0.5
0
06419-011
0
06419-008
80
Data Sheet
–140
10
–145
–10
RELATIVE POWER (dB)
0
–150
–155
–160
–20
–30
–40
–50
–60
–70
–80
–90
–165
–170
0.1
1
10
100
PFD FREQUENCY (MHz)
–110
CENTER 122.88MHz
5MHz/DIV
SPAN 50MHz
06419-137
–100
06419-013
PFD PHASE NOISE REFERRED TO PFD INPUT
(dBc/Hz)
AD9516-0
Figure 16. PFD/CP Spurs; 122.88 MHz; PFD = 15.36 MHz;
LBW = 190 kHz; ICP = 4.2 mA; FVCO = 2.7 GHz
Figure 13. PFD Phase Noise Referred to PFD Input vs. PFD Frequency
–210
10
–212
–10
RELATIVE POWER (dB)
PLL FIGURE OF MERIT (dBc/Hz)
0
–214
–216
–218
–220
–20
–30
–40
–50
–60
–70
–80
–90
–222
0
0.5
1.5
1.0
2.0
2.5
SLEW RATE (V/ns)
–110
06419-136
–224
CENTER 122.8803006MHz
100kHz/DIV
SPAN 1MHz
06419-135
–100
Figure 17. Output Spectrum, LVPECL; 122.88 MHz; PFD = 15.36 MHz;
LBW = 190 kHz; ICP = 4.2 mA; FVCO = 2.7 GHz
Figure 14. PLL Figure of Merit (FOM) vs. Slew Rate at REFIN/REFIN
2.1
10
1.9
–10
RELATIVE POWER (dB)
1.7
1.5
1.3
–20
–30
–40
–50
–60
–70
–80
–90
1.1
0.9
2.55
2.60
2.65
2.70
2.75
2.80
2.85
2.90
2.95
FREQUENCY (GHz)
–110
CENTER 122.8803006MHz
100kHz/DIV
SPAN 1MHz
Figure 18. Output Spectrum, LVDS; 122.88 MHz; PFD = 15.36 MHz;
LBW = 190 kHz; ICP = 4.2 mA; FVCO = 2.7 GHz
Figure 15. VCO Tuning Voltage vs. Frequency
(Note that VCO calibration centers the dc tuning voltage
for the PLL setup that is active during calibration.)
Rev. C | Page 20 of 80
06419-134
–100
06419-138
VCO TUNING VOLTAGE (V)
0
Data Sheet
AD9516-0
0.4
0.6
DIFFERENTIAL OUTPUT (V)
DIFFERENTIAL OUTPUT (V)
1.0
0.2
–0.2
0.2
0
–0.2
–0.6
5
10
15
20
25
TIME (ns)
–0.4
0
1
06419-017
0
06419-014
–1.0
2
TIME (ns)
Figure 19. LVPECL Output (Differential) at 100 MHz
Figure 22. LVDS Output (Differential) at 800 MHz
1.0
DIFFERENTIAL OUTPUT (V)
DIFFERENTIAL OUTPUT (V)
2.8
0.6
0.2
–0.2
1.8
0.8
1
0
2
TIME (ns)
06419-015
–0.2
–1.0
0
20
40
60
80
100
TIME (ns)
Figure 20. LVPECL Output (Differential) at 1600 MHz
06419-018
–0.6
Figure 23.CMOS Output at 25 MHz
0.4
OUTPUT (V)
0.2
0
1.8
0.8
–0.2
–0.4
0
5
10
15
20
TIME (ns)
25
Figure 21. LVDS Output (Differential) at 100 MHz
0
2
4
6
8
TIME (ns)
Figure 24. CMOS Output at 250 MHz
Rev. C | Page 21 of 80
10
12
06419-019
–0.2
06419-016
DIFFERENTIAL OUTPUT (V)
2.8
AD9516-0
Data Sheet
1600
–70
–90
1400
PHASE NOISE (dBc/Hz)
DIFFERENTIAL SWING (mV p-p)
–80
1200
1000
–100
–110
–120
–130
–140
0
1
2
3
FREQUENCY (GHz)
–160
10k
06419-020
800
Figure 25. LVPECL Differential Swing vs. Frequency
Using a Differential Probe Across the Output Pair
100k
1M
10M
100M
FREQUENCY (Hz)
06419-023
–150
Figure 28. Internal VCO Phase Noise (Absolute) Direct to LVPECL at 2950 MHz
–80
–90
PHASE NOISE (dBc/Hz)
DIFFERENTIAL SWING (mV p-p)
700
600
–100
–110
–120
–130
0
100
200
300
400
500
600
700
800
FREQUENCY (MHz)
–150
10k
06419-021
500
Figure 26. LVDS Differential Swing vs. Frequency
Using a Differential Probe Across the Output Pair
1M
10M
100M
FREQUENCY (Hz)
Figure 29. Internal VCO Phase Noise (Absolute) Direct to LVPECL at 2750 MHz
–80
CL = 2pF
3
–90
PHASE NOISE (dBc/Hz)
CL = 10pF
2
CL = 20pF
1
–100
–110
–120
–130
0
0
100
200
300
400
500
600
OUTPUT FREQUENCY (MHz)
Figure 27. CMOS Output Swing vs. Frequency and Capacitive Load
–150
10k
100k
1M
FREQUENCY (Hz)
10M
100M
06419-025
–140
06419-133
OUTPUT SWING (V)
100k
06419-024
–140
Figure 30. Internal VCO Phase Noise (Absolute) Direct to LVPECL at 2550 MHz
Rev. C | Page 22 of 80
Data Sheet
AD9516-0
–120
–110
–125
PHASE NOISE (dBc/Hz)
PHASE NOISE (dBc/Hz)
–120
–130
–135
–140
–145
–150
–130
–140
–150
100
1k
10k
100k
1M
10M
100M
FREQUENCY (Hz)
–160
10
06419-026
–120
–110
PHASE NOISE (dBc/Hz)
–150
1k
10k
100k
1M
10M
100M
10M
100M
–120
–130
–150
10
06419-027
100
100
1k
10k
100k
1M
10M
100M
FREQUENCY (Hz)
Figure 32. Phase Noise (Additive) LVPECL at 200 MHz, Divide-by-5
Figure 35. Phase Noise (Additive) LVDS at 800 MHz, Divide-by-2
–120
–110
–130
PHASE NOISE (dBc/Hz)
–100
–120
–130
–140
–140
–150
–160
100
1k
10k
100k
1M
10M
100M
FREQUENCY (Hz)
06419-128
PHASE NOISE (dBc/Hz)
1M
–140
FREQUENCY (Hz)
–150
10
100k
06419-130
PHASE NOISE (dBc/Hz)
–100
–160
10
10k
Figure 34. Phase Noise (Additive) LVDS at 200 MHz, Divide-by-1
–110
–140
1k
FREQUENCY (Hz)
Figure 31. Phase Noise (Additive) LVPECL at 245.76 MHz, Divide-by-1
–130
100
Figure 33. Phase Noise (Additive) LVPECL at 1600 MHz, Divide-by-1
–170
10
100
1k
10k
100k
1M
10M
100M
FREQUENCY (Hz)
Figure 36. Phase Noise (Additive) CMOS at 50 MHz, Divide-by-20
Rev. C | Page 23 of 80
06419-131
–160
10
06419-142
–155
AD9516-0
Data Sheet
–100
–120
PHASE NOISE (dBc/Hz)
PHASE NOISE (dBc/Hz)
–110
–120
–130
–140
–130
–140
–150
100
1k
10k
100k
1M
10M
100M
FREQUENCY (Hz)
–160
1k
06419-132
–160
10
10k
100k
1M
10M
FREQUENCY (Hz)
100M
06419-140
–150
Figure 40. Phase Noise (Absolute), External VCXO (Toyocom TCO-2112) at
245.76 MHz; PFD = 15.36 MHz; LBW = 250 Hz; LVPECL Output = 245.76 MHz
Figure 37. Phase Noise (Additive) CMOS at 250 MHz, Divide-by-4
1000
–120
–140
–150
–160
1k
10k
100k
1M
10M
100M
FREQUENCY (Hz)
100
FOBJ
10
1
NOTE: 375UI MAX AT 10Hz OFFSET IS THE
MAXIMUM JITTER THAT CAN BE
GENERATED BY THE TEST EQUIPMENT.
FAILURE POINT IS GREATER THAN 375UI.
0.1
0.01
0.1
1
10
JITTER FREQUENCY (kHz)
Figure 38. Phase Noise (Absolute) Clock Generation; Internal VCO at 2.7 GHz;
PFD = 15.36 MHz; LBW = 110 kHz; LVPECL Output = 122.88 MHz
–90
PHASE NOISE (dBc/Hz)
–100
–110
–120
–130
–140
–160
1k
10k
100k
1M
FREQUENCY (Hz)
10M
100M
06419-139
–150
Figure 39. Phase Noise (Absolute) Clock Cleanup; Internal VCO at 2.8 GHz;
PFD = 19.44 MHz; LBW = 12.8 kHz; LVPECL Output = 155.52 MHz
Rev. C | Page 24 of 80
Figure 41. GR-253 Jitter Tolerance Plot
100
1000
06419-148
INPUT JITTER AMPLITUDE (UIPP)
–130
06419-141
PHASE NOISE (dBc/Hz)
OC-48 OBJECTIVE MASK
AD9516
Data Sheet
AD9516-0
TERMINOLOGY
Phase Jitter and Phase Noise
An ideal sine wave can be thought of as having a continuous
and even progression of phase with time from 0° to 360° for
each cycle. Actual signals, however, display a certain amount
of variation from ideal phase progression over time. This
phenomenon is called phase jitter. Although many causes can
contribute to phase jitter, one major cause is random noise,
which is characterized statistically as being Gaussian (normal)
in distribution.
This phase jitter leads to a spreading out of the energy of the
sine wave in the frequency domain, producing a continuous
power spectrum. This power spectrum is usually reported as
a series of values whose units are dBc/Hz at a given offset in
frequency from the sine wave (carrier). The value is a ratio
(expressed in dB) of the power contained within a 1 Hz
bandwidth with respect to the power at the carrier frequency.
For each measurement, the offset from the carrier frequency
is also given.
It is meaningful to integrate the total power contained within
some interval of offset frequencies (for example, 10 kHz to
10 MHz). This is called the integrated phase noise over that
frequency offset interval and can be readily related to the time
jitter due to the phase noise within that offset frequency interval.
Phase noise has a detrimental effect on the performance of
ADCs, DACs, and RF mixers. It lowers the achievable dynamic
range of the converters and mixers, although they are affected
in somewhat different ways.
Time Jitter
Phase noise is a frequency domain phenomenon. In the time
domain, the same effect is exhibited as time jitter. When
observing a sine wave, the time of successive zero crossings
varies. In a square wave, the time jitter is a displacement of the
edges from their ideal (regular) times of occurrence. In both
cases, the variations in timing from the ideal are the time jitter.
Because these variations are random in nature, the time jitter is
specified in units of seconds root mean square (rms) or 1 sigma
of the Gaussian distribution.
Time jitter that occurs on a sampling clock for a DAC or an
ADC decreases the signal-to-noise ratio (SNR) and dynamic
range of the converter. A sampling clock with the lowest possible
jitter provides the highest performance from a given converter.
Additive Phase Noise
Additive phase noise is the amount of phase noise that can be
attributed to the device or subsystem being measured. The phase
noise of any external oscillators or clock sources is subtracted.
This makes it possible to predict the degree to which the device
impacts the total system phase noise when used in conjunction
with the various oscillators and clock sources, each of which
contributes its own phase noise to the total. In many cases, the
phase noise of one element dominates the system phase noise.
When there are multiple contributors to phase noise, the total is
the square root of the sum of squares of the individual contributors.
Additive Time Jitter
Additive time jitter is the amount of time jitter that can be
attributed to the device or subsystem being measured. The time
jitter of any external oscillators or clock sources is subtracted. This
makes it possible to predict the degree to which the device impacts
the total system time jitter when used in conjunction with the
various oscillators and clock sources, each of which contributes
its own time jitter to the total. In many cases, the time jitter of
the external oscillators and clock sources dominates the system
time jitter.
Rev. C | Page 25 of 80
AD9516-0
Data Sheet
DETAILED BLOCK DIAGRAM
REF_ SEL
VS
GND
RSET
REFMON
CPRSET VCP
DISTRIBUTION
REFERENCE
REFERENCE
SWITCHOVER
LD
REF1
STATUS
REF2
R
DIVIDER
STATUS
REFIN (REF1)
PROGRAMMABLE
R DELAY
VCO STATUS
REFIN (REF2)
BYPASS
PLL
REFERENCE
LOCK
DETECT
LOW DROPOUT
REGULATOR (LDO)
P, P + 1
PRESCALER
A/B
COUNTERS
PROGRAMMABLE
N DELAY
PHASE
FREQUENCY
DETECTOR
HOLD
CHARGE
PUMP
CP
N DIVIDER
LF
VCO
STATUS
DIVIDE BY
2, 3, 4, 5, OR 6
CLK
CLK
1
0
OUT0
DIVIDE BY
1 TO 32
PD
SYNC
OUT0
LVPECL
OUT1
DIGITAL
LOGIC
OUT1
RESET
OUT2
DIVIDE BY
1 TO 32
OUT3
SERIAL
CONTROL
PORT
OUT3
OUT4
DIVIDE BY
1 TO 32
OUT4
LVPECL
OUT5
OUT5
OUT6 (OUT6A)
∆t
DIVIDE BY
1 TO 32
DIVIDE BY
1 TO 32
OUT6 (OUT6B)
LVDS/CMOS
OUT7 (OUT7A)
∆t
OUT7 (OUT7B)
OUT8 (OUT8A)
∆t
DIVIDE BY
1 TO 32
DIVIDE BY
1 TO 32
AD9516-0
OUT8 (OUT8B)
LVDS/CMOS
∆t
OUT9 (OUT9A)
OUT9 (OUT9B)
06419-002
SCLK
SDIO
SDO
CS
OUT2
LVPECL
Figure 42. Detailed Block Diagram
Rev. C | Page 26 of 80
Data Sheet
AD9516-0
THEORY OF OPERATION
OPERATIONAL CONFIGURATIONS
Table 21. Default Settings of Some PLL Registers
The AD9516 can be configured in several ways. These
configurations must be set up by loading the control registers
(see Table 52 and Table 53 through Table 62). Each section
or function must be individually programmed by setting the
appropriate bits in the corresponding control register or registers.
Register
0x010[1:0] = 01b
0x1E0[2:0] = 010b
0x1E1[0] = 0b
0x1E1[1] = 0b
High Frequency Clock Distribution—CLK or External
VCO > 1600 MHz
When using the internal PLL with an external VCO, the PLL
must be turned on.
The AD9516 power-up default configuration has the PLL
powered off and the routing of the input set so that the
CLK/CLK input is connected to the distribution section
through the VCO divider (divide-by-2/ divide-by-3/divide-by4/divide-by-5/divide-by-6). This is a distribution only mode
that allows for an external input up to 2400 MHz (see Table 3).
The maximum frequency that can be applied to the channel
dividers is 1600 MHz; therefore, higher input frequencies must
be divided down before reaching the channel dividers. This
input routing can also be used for lower input frequencies, but
the minimum divide is 2 before the channel dividers.
When the PLL is enabled, this routing also allows the use of the
PLL with an external VCO or VCXO with a frequency of less
than 2400 MHz. In this configuration, the internal VCO is
not used and is powered off. The external VCO/VCXO feeds
directly into the prescaler.
The register settings shown in Table 21 are the default values of
these registers at power-up or after a reset operation. If the
contents of the registers are altered by prior programming after
power-up or reset, these registers can also be set intentionally to
these values.
Function
PLL asynchronous power-down (PLL off ).
Set VCO divider = 4.
Use the VCO divider.
CLK selected as the source.
Table 22. Settings When Using an External VCO
Register
0x010[1:0] = 00b
0x010 to 0x01D
0x1E1[1] = 0b
Function
PLL normal operation (PLL on).
PLL settings. Select and enable a reference
input; set R, N (P, A, B), PFD polarity, and ICP,
according to the intended loop configuration.
CLK selected as the source.
An external VCO requires an external loop filter that must be
connected between CP and the tuning pin of the VCO. This
loop filter determines the loop bandwidth and stability of the
PLL. Make sure to select the proper PFD polarity for the VCO
being used.
Table 23. Setting the PFD Polarity
Register
0x010[7] = 0b
0x010[7] = 1b
After the appropriate register values are programmed,
Register 0x232 must be set to 0x01 for the values to take effect.
Rev. C | Page 27 of 80
Function
PFD polarity positive (higher control
voltage produces higher frequency).
PFD polarity negative (higher control
voltage produces lower frequency).
AD9516-0
Data Sheet
REF_SEL
VS
GND
RSET
REFMON
CPRSET VCP
DISTRIBUTION
REFERENCE
REFERENCE
SWITCHOVER
LD
REF1
STATUS
REF2
R
DIVIDER
STATUS
REFIN (REF1)
PROGRAMMABLE
R DELAY
VCO STATUS
REFIN (REF2)
BYPASS
PLL
REFERENCE
LOCK
DETECT
LOW DROPOUT
REGULATOR (LDO)
P, P + 1
PRESCALER
A/B
COUNTERS
PROGRAMMABLE
N DELAY
PHASE
FREQUENCY
DETECTOR
HOLD
CHARGE
PUMP
CP
N DIVIDER
LF
VCO
STATUS
DIVIDE BY
2, 3, 4, 5, OR 6
CLK
CLK
1
0
OUT0
DIVIDE BY
1 TO 32
PD
SYNC
OUT0
LVPECL
OUT1
DIGITAL
LOGIC
OUT1
RESET
OUT2
DIVIDE BY
1 TO 32
OUT3
SERIAL
CONTROL
PORT
OUT3
OUT4
DIVIDE BY
1 TO 32
OUT4
LVPECL
OUT5
OUT5
OUT6 (OUT6A)
∆t
DIVIDE BY
1 TO 32
DIVIDE BY
1 TO 32
OUT6 (OUT6B)
LVDS/CMOS
OUT7 (OUT7A)
∆t
OUT7 (OUT7B)
OUT8 (OUT8A)
∆t
DIVIDE BY
1 TO 32
DIVIDE BY
1 TO 32
AD9516-0
OUT8 (OUT8B)
LVDS/CMOS
∆t
OUT9 (OUT9A)
OUT9 (OUT9B)
06419-029
SCLK
SDIO
SDO
CS
OUT2
LVPECL
Figure 43. High Frequency Clock Distribution or External VCO > 1600 MHz
Rev. C | Page 28 of 80
Data Sheet
AD9516-0
REF_SEL
VS
GND
RSET
REFMON
CPRSET VCP
DISTRIBUTION
REFERENCE
REFERENCE
SWITCHOVER
LD
REF1
STATUS
REF2
R
DIVIDER
STATUS
REFIN (REF1)
PROGRAMMABLE
R DELAY
VCO STATUS
REFIN (REF2)
BYPASS
PLL
REFERENCE
LOCK
DETECT
LOW DROPOUT
REGULATOR (LDO)
P, P + 1
PRESCALER
A/B
COUNTERS
PROGRAMMABLE
N DELAY
PHASE
FREQUENCY
DETECTOR
HOLD
CHARGE
PUMP
CP
N DIVIDER
LF
VCO
STATUS
DIVIDE BY
2, 3, 4, 5, OR 6
CLK
CLK
1
OUT0
0
DIVIDE BY
1 TO 32
PD
SYNC
OUT0
LVPECL
OUT1
DIGITAL
LOGIC
OUT1
RESET
OUT2
DIVIDE BY
1 TO 32
SCLK
SDIO
SDO
CS
OUT2
LVPECL
OUT3
SERIAL
CONTROL
PORT
OUT3
OUT4
DIVIDE BY
1 TO 32
OUT4
LVPECL
OUT5
OUT5
OUT6 (OUT6A)
∆t
DIVIDE BY
1 TO 32
OUT6 (OUT6B)
LVDS/CMOS
OUT7 (OUT7A)
∆t
OUT7 (OUT7B)
OUT8 (OUT8A)
∆t
DIVIDE BY
1 TO 32
DIVIDE BY
1 TO 32
AD9516-0
OUT8 (OUT8B)
LVDS/CMOS
∆t
OUT9 (OUT9A)
OUT9 (OUT9B)
06419-030
DIVIDE BY
1 TO 32
Figure 44. Internal VCO and Clock Distribution
Table 24. Settings When Using Internal VCO
Internal VCO and Clock Distribution
When using the internal VCO and PLL, the VCO divider
must be employed to ensure that the frequency presented to
the channel dividers does not exceed their specified maximum
frequency of 1600 MHz (see Table 3). The internal PLL uses an
external loop filter to set the loop bandwidth. The external loop
filter is also crucial to the loop stability.
Register
0x010[1:0] = 00b
0x010 to 0x01E
0x018[0] = 0b,
0x232[0] = 1b
When using the internal VCO, it is necessary to calibrate the
VCO (Register 0x018[0]) to ensure optimal performance.
0x1E0[2:0]
For internal VCO and clock distribution applications, use
the register settings that are shown in Table 24.
0x1E1[0] = 0b
0x1E1[1] = 1b
0x018[0] = 1b,
0x232[0] = 1b
Rev. C | Page 29 of 80
Function
PLL normal operation (PLL on).
PLL settings. Select and enable a reference
input; set R, N (P, A, B), PFD polarity, and ICP,
according to the intended loop configuration.
Reset VCO calibration. This is not required
the first time after power-up, but it must
be performed subsequently.
Set VCO divider to divide-by-2, divide-by-3,
divide-by-4, divide-by-5, and divide-by-6.
Use the VCO divider as source for the
distribution section.
Select VCO as the source.
Initiate VCO calibration.
AD9516-0
Data Sheet
REF_SEL
VS
GND
RSET
REFMON
CPRSET VCP
DISTRIBUTION
REFERENCE
REFERENCE
SWITCHOVER
LD
REF1
STATUS
REF2
R
DIVIDER
STATUS
REFIN (REF1)
PROGRAMMABLE
R DELAY
VCO STATUS
REFIN (REF2)
BYPASS
PLL
REFERENCE
LOCK
DETECT
LOW DROPOUT
REGULATOR (LDO)
P, P + 1
PRESCALER
A/B
COUNTERS
PROGRAMMABLE
N DELAY
PHASE
FREQUENCY
DETECTOR
HOLD
CHARGE
PUMP
CP
N DIVIDER
LF
VCO
STATUS
DIVIDE BY
2, 3, 4, 5, OR 6
CLK
CLK
1
0
OUT0
DIVIDE BY
1 TO 32
PD
SYNC
OUT0
LVPECL
OUT1
DIGITAL
LOGIC
OUT1
RESET
OUT2
DIVIDE BY
1 TO 32
OUT3
SERIAL
CONTROL
PORT
OUT3
OUT4
DIVIDE BY
1 TO 32
OUT4
LVPECL
OUT5
OUT5
OUT6 (OUT6A)
∆t
DIVIDE BY
1 TO 32
DIVIDE BY
1 TO 32
OUT6 (OUT6B)
LVDS/CMOS
OUT7 (OUT7A)
∆t
OUT7 (OUT7B)
OUT8 (OUT8A)
∆t
DIVIDE BY
1 TO 32
DIVIDE BY
1 TO 32
AD9516-0
OUT8 (OUT8B)
LVDS/CMOS
∆t
OUT9 (OUT9A)
OUT9 (OUT9B)
06419-028
SCLK
SDIO
SDO
CS
OUT2
LVPECL
Figure 45. Clock Distribution or External VCO < 1600 MHz
Rev. C | Page 30 of 80
Data Sheet
AD9516-0
Clock Distribution or External VCO < 1600 MHz
When the external clock source to be distributed or the external
VCO/VCXO is less than 1600 MHz, a configuration that bypasses
the VCO divider can be used. This configuration differs from the
High Frequency Clock Distribution—CLK or External VCO >
1600 MHz section only in that the VCO divider (divide-by-2,
divide-by-3, divide-by-4, divide-by-5, and divide-by-6) is
bypassed. This limits the frequency of the clock source to
<1600 MHz (due to the maximum input frequency allowed at
the channel dividers).
Configuration and Register Settings
For clock distribution applications where the external clock is
<1600 MHz, use the register settings that are shown in Table 25.
Table 25. Settings for Clock Distribution < 1600 MHz
Register
0x010[1:0] = 01b
0x1E1[0] = 1b
0x1E1[1] = 0b
Function
PLL asynchronous power-down (PLL off )
Bypass the VCO divider as source for
distribution section
CLK selected as the source
When using the internal PLL with an external VCO of <1600 MHz,
the PLL must be turned on.
Table 26. Settings for Using Internal PLL with External VCO <
1600 MHz
Register
0x1E1[0] = 1b
0x010[1:0] = 00b
Function
Bypass the VCO divider as source for
distribution section
PLL normal operation (PLL on), along with
other appropriate PLL settings in Register 0x010
to Register 0x01E
An external VCO/VCXO requires an external loop filter that
must be connected between CP and the tuning pin of the
VCO/VCXO. This loop filter determines the loop bandwidth
and stability of the PLL. Make sure to select the proper PFD
polarity for the VCO/VCXO being used.
Table 27. Setting the PFD Polarity
Register
0x010[7] = 0b
0x010[7] = 1b
Function
PFD polarity positive (higher control voltage
produces higher frequency)
PFD polarity negative (higher control voltage
produces lower frequency)
After the appropriate register values are programmed,
Register 0x232 must be set to 0x01 for the values to take effect.
Rev. C | Page 31 of 80
AD9516-0
Data Sheet
Phase-Locked Loop (PLL)
REF_SEL
VS
GND
RSET
REFMON
CPRSET
VCP
DIST
REF
REFERENCE
SWITCHOVER
LD
LOCK
DETECT
REF1
STATUS
REF2
PROGRAMMABLE
R DELAY
R DIVIDER
PLL
REF
STATUS
HOLD
REFIN (REF1)
REFIN (REF2)
BYPASS
PHASE
FREQUENCY
DETECTOR
N DIVIDER
LOW DROPOUT
REGULATOR (LDO)
P, P + 1
PRESCALER
A/B
COUNTERS
CHARGE PUMP
CP
PROGRAMMABLE
N DELAY
VCO STATUS
LF
STATUS
VCO
DIVIDE BY
2, 3, 4, 5, OR 6
CLK
0
1
06419-064
1
CLK
0
Figure 46. PLL Functional Blocks
The AD9516 includes an on-chip PLL with an on-chip VCO.
The PLL blocks can be used either with the on-chip VCO to
create a complete phase-locked loop, or with an external VCO
or VCXO. The PLL requires an external loop filter, which
usually consists of a small number of capacitors and resistors.
The configuration and components of the loop filter help to
establish the loop bandwidth and stability of the operating PLL.
These are managed through programmable register settings
(see Table 52 and Table 54) and by the design of the external
loop filter. Successful PLL operation and satisfactory PLL loop
performance are highly dependent upon proper configuration of
the PLL settings. The design of the external loop filter is crucial
to the proper operation of the PLL. A thorough knowledge of
PLL theory and design is helpful.
The AD9516 PLL is useful for generating clock frequencies
from a supplied reference frequency. This includes conversion
of reference frequencies to much higher frequencies for subsequent
division and distribution. In addition, the PLL can be exploited to
clean up jitter and phase noise on a noisy reference. The exact
choices of PLL parameters and loop dynamics are very application
specific. The flexibility and depth of the AD9516 PLL allow the
part to be tailored to function in many different applications
and signal environments.
ADIsimCLK™ (V1.2 or later) is a free program that can help
with the design and exploration of the capabilities and features
of the AD9516, including the design of the PLL loop filter. It is
available at www.analog.com/clocks.
Configuration of the PLL
The AD9516 allows flexible configuration of the PLL,
accommodating various reference frequencies, PFD comparison
frequencies, VCO frequencies, internal or external VCO/VCXO,
and loop dynamics. This is accomplished by the various settings
that include the R divider, the N divider, the PFD polarity (only
applicable to external VCO/VCXO), the antibacklash pulse
width, the charge pump current, the selection of internal VCO
or external VCO/VCXO, and the loop bandwidth.
Phase Frequency Detector (PFD)
The PFD takes inputs from the R counter and N counter and
produces an output proportional to the phase and frequency
difference between them. The PFD includes a programmable
delay element that controls the width of the antibacklash pulse.
This pulse ensures that there is no dead zone in the PFD
transfer function and minimizes phase noise and reference
spurs. The antibacklash pulse width is set by Register 0x017[1:0].
An important limit to keep in mind is the maximum frequency
allowed into the PFD, which in turn determines the correct
antibacklash pulse setting. The antibacklash pulse setting is
specified in the phase/frequency detector parameter of Table 2.
Rev. C | Page 32 of 80
Data Sheet
AD9516-0
Charge Pump (CP)
AD9516-0
VCO
LF
31pF
R2
CP
R1
CHARGE
PUMP
BYPASS
C1
Figure 47. Example of External Loop Filter for a PLL Using the Internal VCO
When using an external VCO, the external loop filter should be
referenced to ground. See Figure 48 for an example of an external
loop filter for a PLL using an external VCO.
AD9516-0
EXTERNAL
VCO/VCXO
CLK/CLK
R2
CP
The on-chip VCO is powered by an on-chip, low dropout
(LDO), linear voltage regulator. The LDO provides some
isolation of the VCO from variations in the power supply
voltage level. The BYPASS pin should be connected to ground
by a 220 nF capacitor to ensure stability. This LDO employs the
same technology used in the anyCAP® line of regulators from
Analog Devices, Inc., making it insensitive to the type of
capacitor used. Driving an external load from the BYPASS pin
is not supported.
Note that the reference input signal must be present and the
VCO divider must not be static during VCO calibration.
PLL External Loop Filter
When using the internal VCO, the external loop filter should
be referenced to the BYPASS pin for optimal noise and spurious
performance. An example of an external loop filter for a PLL
that uses the internal VCO is shown in Figure 47. The third-order
design shown in Figure 47 usually offers best performance. A
loop filter must be calculated for each desired PLL configuration.
The values of the components depend upon the VCO frequency,
the KVCO, the PFD frequency, the CP current, the desired loop
bandwidth, and the desired phase margin. The loop filter affects
the phase noise, the loop settling time, and loop stability. A basic
knowledge of PLL theory is helpful for understanding loop filter
design. ADIsimCLK can help with calculation of a loop filter
according to the application requirements.
C3
CBP = 220nF
On-Chip VCO
CHARGE
PUMP
R1
C1
C2
C3
06419-265
The AD9516 includes an on-chip VCO covering the frequency
range shown in Table 2. The calibration procedure ensures that
the VCO operating voltage is centered for the desired VCO
frequency. The VCO must be calibrated when the VCO loop is
first set up, as well as any time the nominal VCO frequency
changes. However, once the VCO is calibrated, the VCO has
sufficient operating range to stay locked over temperature and
voltage extremes without needing additional calibration. See
the VCO Calibration section for more information.
C2
06419-065
The charge pump is controlled by the PFD. The PFD monitors
the phase and frequency relationship between its two inputs,
and tells the CP to pump up or pump down to charge or discharge
the integrating node (part of the loop filter). The integrated and
filtered CP current is transformed into a voltage that drives the
tuning node of the internal VCO through the LF pin (or the tuning
pin of an external VCO) to move the VCO frequency up or down.
The CP can be set (Register 0x010[6:4]) for high impedance
(allows holdover operation), for normal operation (attempts to
lock the PLL loop), for pump up, or for pump down (test modes).
The CP current is programmable in eight steps from (nominally)
600 µA to 4.8 mA. The exact value of the CP current LSB is set
by the CPRSET resistor, which is nominally 5.1 kΩ. If the value
of the resistor connected to the CP_RSET pin is doubled, the
resulting charge pump current range becomes 300 µA to 2.4 mA.
Figure 48. Example of External Loop Filter for a PLL Using an External VCO
PLL Reference Inputs
The AD9516 features a flexible PLL reference input circuit that
allows either a fully differential input or two separate singleended inputs. The input frequency range for the reference
inputs is specified in Table 2. Both the differential and the
single-ended inputs are self-biased, allowing for easy ac
coupling of input signals.
The differential input and the single-ended inputs share the two
pins, REFIN/REFIN (REF1 and REF2, respectively). The desired
reference input type is selected and controlled by Register 0x01C
(see Table 52 and Table 54).
When the differential reference input is selected, the self-bias
level of the two sides is offset slightly (~100 mV, see Table 2) to
prevent chattering of the input buffer when the reference is slow
or missing. This increases the voltage swing that is required of the
driver and overcomes the offset. The differential reference input
can be driven by either ac-coupled LVDS or ac-coupled LVPECL
signals.
The single-ended inputs can be driven by either a dc-coupled
CMOS level signal or an ac-coupled sine wave or square wave.
Each single-ended input can be independently powered down
when not needed to increase isolation and reduce power. Either
a differential or a single-ended reference must be specifically
enabled. All PLL reference inputs are off by default.
The differential reference input is powered down whenever the
PLL is powered down, or when the differential reference input
is not selected. The single-ended buffers power down when the
PLL is powered down, and when their individual power down
registers are set. When the differential mode is selected, the
single-ended inputs are powered down.
Rev. C | Page 33 of 80
AD9516-0
Data Sheet
In differential mode, the reference input pins are internally selfbiased so that they can be ac-coupled via capacitors. It is possible
to dc couple to these inputs. If the differential REFIN is driven
by a single-ended signal, the unused side (REFIN) should be
decoupled via a suitable capacitor to a quiet ground. Figure 49
shows the equivalent circuit of REFIN.
VS
Automatic revertive switchover relies on the REFMON pin to
indicate when REF1 disappears. By programming Register 0x01B =
0xF7 and Register 0x01C = 0x26, the REFMON pin is programmed
to be high when REF1 is invalid, which commands the switch to
REF2. When REF1 is valid again, the REFMON pin goes low, and
the part again locks to REF1. It is also possible to use the STATUS
pin for this function, and REF2 can be used as the preferred
reference.
A switchover deglitch feature ensures that the PLL does not
receive rising edges that are far out of alignment with the newly
selected reference.
85kΩ
REF1
Automatic nonrevertive switching is not supported.
Reference Divider R
VS
10kΩ
The reference inputs are routed to the reference divider, R.
R (a 14-bit counter) can be set to any value from 0 to 16383 by
writing to Register 0x011 and Register 0x012. (Both R = 0 and
R = 1 give divide-by-1.) The output of the R divider goes to one
of the PFD inputs to be compared to the VCO frequency divided
by the N divider. The frequency applied to the PFD must not
exceed the maximum allowable frequency, which depends on
the antibacklash pulse setting (see Table 2).
12kΩ
REFIN
150Ω
REFIN
150Ω
10kΩ
10kΩ
VS
REF2
The R counter has its own reset. R counter can be reset using
the shared reset bit of the R, A, and B counters. It can also be
reset by a SYNC operation.
06419-066
85kΩ
VCXO/VCO Feedback Divider N—P, A, B, R
The N divider is a combination of a prescaler (P) and two
counters, A and B. The total divider value is
Figure 49. REFIN Equivalent Circuit
Reference Switchover
The AD9516 supports dual single-ended CMOS inputs, as well
as a single differential reference input. In the dual single-ended
reference mode, the AD9516 supports automatic and manual
PLL reference clock switching between REF1 (on Pin REFIN)
and REF2 (on Pin REFIN). This feature supports networking
and other applications that require smooth switching of redundant
references. When used in conjunction with the automatic
holdover function, the AD9516 can achieve a worst-case
reference input switchover with an output frequency disturbance
as low as 10 ppm.
When using reference switchover, the single-ended reference
inputs should be dc-coupled CMOS levels and never be allowed
to go to high impedance. If these inputs are allowed to go to high
impedance, noise may cause the buffer to chatter, causing a false
detection of the presence of a reference.
Reference switchover can be performed manually or automatically. Manual switchover is performed either through
Register 0x01C or by using the REF_SEL pin. Manual switchover
requires the presence of a clock on the reference input that is
being switched to, or that the deglitching feature be disabled
(Register 0x01C[7]). The reference switching logic fails if this
condition isn’t met, and the PLL does not reacquire.
N = (P × B) + A
where the value of P can be 2, 4, 8, 16, or 32.
Prescaler
The prescaler of the AD9516 allows for two modes of operation:
a fixed divide (FD) mode of 1, 2, or 3, and dual modulus (DM)
mode where the prescaler divides by P and (P + 1) {2 and 3, 4
and 5, 8 and 9, 16 and 17, or 32 and 33}. The prescaler modes of
operation are given in Table 54, Register 0x016[2:0]. Not all
modes are available at all frequencies (see Table 2).
When operating the AD9516 in dual modulus mode (P//P + 1),
the equation used to relate input reference frequency to VCO
output frequency is
fVCO = (fREF/R) × (P × B + A) = fREF × N/R
However, when operating the prescaler in FD mode, 1, 2, or 3,
the A counter is not used (A = 0) and the equation simplifies to
fVCO = (fREF/R) × (P × B) = fREF × N/R
When A = 0, the divide is a fixed divide of P = 2, 4, 8, 16, or 32,
in which case the previous equation also applies.
Rev. C | Page 34 of 80
Data Sheet
AD9516-0
By using combinations of DM and FD modes, the AD9516 can
achieve values of N all the way down to N = 1 and up to N =
26,2175. Table 28 shows how a 10 MHz reference input can be
locked to any integer multiple of N.
Note that the same value of N can be derived in different ways,
as illustrated by the case of N = 12. The user can choose a fixed
divide mode of P = 2 with B = 6; use the dual modulus mode of
2/3 with A = 0, B = 6; or use the dual modulus mode of 4/5 with
A = 0, B = 3.
The maximum frequency into the prescaler in 2/3 dual-modulus
mode is limited to 200 MHz. There are only two cases where
this frequency limitation limits the flexibility of that N divider:
N = 7 and N = 11. In these two cases, the maximum frequency
into the prescaler is 300 MHz and is achieved by using the P = 1
FD mode. In all other cases, the user can achieve the desired N
divider value by using the other prescaler modes.
A and B Counters
The B counter must be ≥3 or bypassed, and, unlike the R counter,
A = 0 is actually zero.
When the prescaler is in dual modulus mode, the A counter
must be less than the B counter.
The maximum input frequency to the A/B counter is reflected
in the maximum prescaler output frequency (~300 MHz) that is
specified in Table 2. This is the prescaler input frequency (VCO or
CLK) divided by P. For example, a dual modulus mode of P = 8/9
is not allowed if the VCO frequency is greater than 2400 MHz
because the frequency going to the A/B counter is too high.
When the AD9516 B counter is bypassed (B = 1), the A counter
should be set to 0, and the overall resulting divide is equal to the
prescaler setting, P. The possible divide ratios in this mode are
1, 2, 3, 4, 8, 16, and 32. This mode is useful only when an
external VCO/VCXO is used because the frequency range of the
internal VCO requires an overall feedback divider greater than 32.
Although manual reset is not normally required, the A/B counters
have their own reset bit. Alternatively, the A and B counters can be
reset using the shared reset bit of the R, A, and B counters. Note
that these reset bits are not self-clearing.
R, A, and B Counters—SYNC Pin Reset
The R, A, and B counters can also be reset simultaneously through
the SYNC pin. This function is controlled by Register 0x019[7:6]
(see Table 54). The SYNC pin reset is disabled by default.
R and N Divider Delays
Both the R and N dividers feature a programmable delay cell.
These delays can be enabled to allow adjustment of the phase
relationship between the PLL reference clock and the VCO or
CLK. Each delay is controlled by three bits. The total delay
range is about 1 ns. See Register 0x019 in Table 54.
Table 28. Using a 10 MHz Reference Input to Generate Different VCO Frequencies
fREF
(MHz)
10
10
10
10
10
10
10
10
R
1
1
1
1
1
1
1
1
P
1
2
1
1
1
2
2
2
A
X
X
X
X
X
X
0
1
B
1
1
3
4
5
3
3
3
N
1
2
3
4
5
6
6
7
fVCO
(MHz)
10
20
30
40
50
60
60
70
Mode
FD
FD
FD
FD
FD
FD
DM
DM
10
10
10
10
10
10
10
10
1
1
1
1
1
10
1
1
2
2
8
8
16
32
8
16
2
1
6
7
7
6
0
14
3
4
18
18
9
47
25
16
8
9
150
151
151
1510
200
270
80
90
1500
1510
1510
1510
2000
2700
DM
DM
DM
DM
DM
DM
DM
DM
10
10
32
22
84
2710
2710
DM
Comments/Conditions
P = 1, B = 1 (A and B counters are bypassed).
P = 2, B = 1 (A and B counters are bypassed).
A counter is bypassed.
A counter is bypassed.
A counter is bypassed.
A counter is bypassed.
Maximum frequency into prescaler in P = 2/3 mode is 200 MHz.
If N = 7 or N = 11 is desired for prescaler input frequency of 200 MHz
to 300 MHz, use P = 1, and N = 7 or 11, respectively.
P = 8 is not allowed (2700 ÷ 8 > 300 MHz).
P = 32 is not allowed (A > B not allowed).
P = 32, A = 22, B = 84.
P = 16 is also permitted.
Rev. C | Page 35 of 80
AD9516-0
Data Sheet
DIGITAL LOCK DETECT (DLD)
By selecting the proper output through the mux on each pin,
the DLD function can be made available at the LD, STATUS,
and REFMON pins. The DLD circuit indicates a lock when the
time difference of the rising edges at the PFD inputs is less than
a specified value (the lock threshold). The loss of a lock is
indicated when the time difference exceeds a specified value
(the unlock threshold). Note that the unlock threshold is wider
than the lock threshold, which allows some phase error in
excess of the lock window to occur without chattering on the
lock indicator.
The lock detect window timing depends on three settings: the
digital lock detect window bit (Register 0x018[4]), the antibacklash pulse width setting (Register 0x017[1:0], see Table 2),
and the lock detect counter (Register 0x018[6:5]). A lock is not
indicated until there is a programmable number of consecutive
PFD cycles with a time difference that is less than the lock
detect threshold. The lock detect circuit continues to indicate
a lock until a time difference greater than the unlock threshold
occurs on a single subsequent cycle. For the lock detect to work
properly, the period of the PFD frequency must be greater than
the unlock threshold. The number of consecutive PFD cycles
required for lock is programmable (Register 0x018[6:5]).
the current source lock detect function. This function is set
when it is selected as the output from the LD pin control
(Register 0x01A[5:0]).
The current source lock detect provides a current of 110 µA
when DLD is true, and it shorts to ground when DLD is false.
If a capacitor is connected to the LD pin, it charges at a rate that
is determined by the current source during the DLD true time
but is discharged nearly instantly when DLD is false. By
monitoring the voltage at the LD pin (top of the capacitor), it is
possible to get a logic high level only after the DLD has been
true for a sufficiently long time. Any momentary DLD false
resets the charging. By selecting a properly sized capacitor, it is
possible to delay a lock detect indication until the PLL is stably
locked, and the lock detect does not chatter.
The voltage on the capacitor can be sensed by an external
comparator connected to the LD pin. However, there is an
internal LD pin comparator that can be read at the REFMON
pin control (Register 0x01B[4:0]) or the STATUS pin control
(Register 0x017[7:2]) as an active high signal. It is also available
as an active low signal (REFMON, Register 0x01B[4:0] and
STATUS, Register 0x017[7:2]). The internal LD pin comparator
trip point and hysteresis are listed in Table 16.
AD9516-0
Analog Lock Detect (ALD)
110µA
The AD9516 provides an ALD function that can be selected for
use at the LD pin. There are two versions of ALD, as follows:
•
N-channel open-drain lock detect. This signal requires
a pull-up resistor to positive supply, VS. The output is
normally high with short, low going pulses. Lock is indicated
by the minimum duty cycle of the low-going pulses.
P-channel open-drain lock detect. This signal requires
a pull-down resistor to GND. The output is normally
low with short, high going pulses. Lock is indicated by
the minimum duty cycle of the high-going pulses.
The analog lock detect function requires an R-C filter to
provide a logic level indicating lock/unlock.
C
LD PIN
COMPARATOR
REFMON
OR
STATUS
Figure 51. Current Source Lock Detect
External VCXO/VCO Clock Input (CLK/CLK)
CLK is a differential input that can be used as an input to drive
the AD9516 clock distribution section. This input can receive
up to 2.4 GHz. The pins are internally self-biased and the input
signal should be ac-coupled via capacitors.
CLOCK INPUT
STAGE
VS = 3.3V
AD9516-0
R2
LD
R1
VOUT
LD
06419-068
•
DLD
VS
VOUT
CLK
C
06419-067
CLK
2.5kΩ
2.5kΩ
5kΩ
Figure 50. Example of Analog Lock Detect Filter,
Using N-Channel Open-Drain Driver
5kΩ
Current Source Digital Lock Detect (DLD)
During the PLL locking sequence, it is normal for the DLD
signal to toggle a number of times before remaining steady
when the PLL is completely locked and stable. There may be
applications where it is desirable to have DLD asserted only
after the PLL is solidly locked. This is made possible by using
06419-032
ALD
Figure 52. CLK Equivalent Input Circuit
The CLK/CLK input can be used either as a distribution only
input (with the PLL off), or as a feedback input for an external
VCO/VCXO using the internal PLL, when the internal VCO is
not used. The CLK/CLK input can be used for frequencies up
to 2.4 GHz.
Rev. C | Page 36 of 80
Data Sheet
AD9516-0
Holdover
Automatic/Internal Holdover Mode
The AD9516 PLL has a holdover function. Holdover is
implemented by putting the charge pump into a state of high
impedance. This is useful when the PLL reference clock is lost.
Holdover mode allows the VCO to maintain a relatively constant
frequency even though there is no reference clock. Without this
function, the charge pump is placed into a constant pump-up or
pump-down state resulting in a massive VCO frequency shift.
Because the charge pump is placed in a high impedance state,
any leakage that occurs at the charge pump output or the VCO
tuning node causes a drift of the VCO frequency. This can be
mitigated by using a loop filter that contains a large capacitive
component because this drift is limited by the current leakageinduced slew rate (ILEAK/C) of the VCO control voltage. For most
applications, the frequency accuracy is sufficient for 3 sec to 5 sec.
When enabled, this function automatically puts the charge
pump into a high impedance state when the loop loses lock.
The assumption is that the only reason the loop loses lock is due
to the PLL losing the reference clock; therefore, the holdover
function puts the charge pump into a high impedance state to
maintain the VCO frequency as close as possible to the original
frequency before the reference clock disappears.
See Figure 53 for a flowchart of the internal/automatic holdover
function operation.
PLL ENABLED
Both a manual holdover, using the SYNC pin, and an automatic
holdover mode are provided. To use either function, the
holdover function must be enabled (Register 0x01D[0] and
Register 0x01D[2]).
Manual Holdover Mode
A manual holdover mode can be enabled that allows the user
to place the charge pump into a high impedance state when the
SYNC pin is asserted low. This operation is edge sensitive, not
level sensitive. The charge pump enters a high impedance state
immediately. To take the charge pump out of a high impedance
state take the SYNC pin high. The charge pump then leaves
high impedance state synchronously with the next PFD rising
edge from the reference clock. This prevents extraneous charge
pump events from occurring during the time between SYNC
going high and the next PFD event. This also means that the
charge pump stays in a high impedance state as long as there
is no reference clock present.
The B counter (in the N divider) is reset synchronously with the
charge pump leaving the high impedance state on the reference
path PFD event. This helps align the edges out of the R and N
dividers for faster settling of the PLL. Because the prescaler is
not reset, this feature works best when the B and R numbers are
close because this results in a smaller phase difference for the
loop to settle out.
DLD == LOW
YES
NO
ANALOG LOCK DETECT PIN INDICATES
LOCK WAS PREVIOUSLY ACHIEVED.
REGISTER 0x1D[3] = 1: USE LD PIN
VOLTAGE WITH HOLDOVER.
REGISTER 0x1D[3] = 0: IGNORE LD PIN
VOLTAGE,TREAT LD PIN AS ALWAYS HIGH.
WAS
LD PIN == HIGH
WHEN DLD WENT
LOW?
YES
CHARGE PUMP IS MADE
HIGH IMPEDANCE.
PLL COUNTERS CONTINUE
OPERATING NORMALLY.
HIGH IMPEDANCE
CHARGE PUMP
YES
NO
CHARGE PUMP REMAINS HIGH
IMPEDANCE UNTIL THE REFERENCE
HAS RETURNED.
REFERENCE
EDGE AT PFD?
YES
YES
TAKE CHARGE PUMP OUT OF
HIGH IMPEDANCE. PLL CAN
NOW RESETTLE.
RELEASE
CHARGE PUMP
HIGH IMPEDANCE
When using this mode, set the channel dividers to ignore the
SYNC pin (at least after an initial SYNC event). If the dividers are
not set to ignore the SYNC pin, the distribution outputs turn off
each time SYNC is taken low to put the part into holdover.
Rev. C | Page 37 of 80
YES
NO
DLD == HIGH
WAIT FOR DLD TO GO HIGH. THIS TAKES
5 TO 255 CYCLES (PROGRAMMING OF
THE DLD DELAY COUNTER) WITH THE
REFERENCE AND FEEDBACK CLOCKS
INSIDE THE LOCK WINDOW AT THE PFD.
THIS ENSURES THAT THE HOLDOVER
FUNCTION WAITS FOR THE PLL TO SETTLE
AND LOCK BEFORE THE HOLDOVER
FUNCTION CAN BE RETRIGGERED.
Figure 53. Flowchart of Automatic/Internal Holdover Mode
06419-069
Note that the VCO cannot be calibrated with the holdover enabled
because the holdover resets the N divider during calibration,
which prevents proper calibration. Disable holdover before
issuing a VCO calibration.
LOOP OUT OF LOCK. DIGITAL LOCK
DETECT SIGNAL GOES LOW WHEN THE
LOOP LEAVES LOCK AS DETERMINED
BY THE PHASE DIFFERENCE AT THE
INPUT OF THE PFD.
NO
AD9516-0
Data Sheet
The holdover function senses the logic level of the LD pin as a
condition to enter holdover. The signal at LD can be from the
DLD, ALD, or current source LD mode. It is possible to disable
the LD comparator (Register 0x01D[3]), which causes the holdover
function to always sense LD as high. If DLD is used, it is possible
for the DLD signal to chatter some while the PLL is reacquiring
lock. The holdover function may retrigger, thereby preventing
the holdover mode from ever terminating. Use of the current
source lock detect mode is recommended to avoid this situation
(see the Current Source Digital Lock Detect section).
Once in holdover mode, the charge pump stays in a high
impedance state as long as there is no reference clock present.
As in the external holdover mode, the B counter (in the N
divider) is reset synchronously with the charge pump leaving the
high impedance state on the reference path PFD event. This
helps align the edges out of the R and N dividers for faster settling
of the PLL and to reduce frequency errors during settling. Because
the prescaler is not reset, this feature works best when the B and
R numbers are close because this results in a smaller phase
difference for the loop to settle out.
After leaving holdover, the loop then reacquires lock and the
LD pin must charge (if Register 0x01D[3] = 1) before it can
re-enter holdover (CP high impedance).
The holdover function always responds to the state of the
currently selected reference (Register 0x01C). If the loop loses
lock during a reference switchover (see the Reference Switchover
section), holdover is triggered briefly until the next reference
clock edge at the PFD.
The following registers affect the internal/automatic holdover
function:
•
•
•
•
•
•
Register 0x018[6:5], lock detect counter. These bits change
the number of consecutive PFD cycles with edges inside the
lock detect window that are required for the DLD indicator
to indicate lock. This impacts the time required before the
LD pin can begin to charge as well as the delay from the end
of a holdover event until the holdover function can be
reengaged.
Register 0x018[3], disable digital lock detect. This bit must
be set to a 0 to enable the DLD circuit. Internal/automatic
holdover does not operate correctly without the DLD function
enabled.
Register 0x01A[5:0], lock detect pin output select. Set these
bits to 000100b for the current source lock detect mode if
using the LD pin comparator. Load the LD pin with a
capacitor of an appropriate value.
Register 0x01D[3], enable LD pin comparator. 1 = enable,
0 = disable. When disabled, the holdover function always
senses the LD pin as high.
Register 0x01D[1], enable external holdover control.
Register 0x01D[0] and Register 0x01D[2], holdover
function enable. If holdover is disabled, both external and
internal/automatic holdover are disabled.
For example, to use automatic holdover with the following:
•
•
•
Automatic reference switchover, prefer REF1
Digital lock detect: five PFD cycles, high range window
Automatic holdover using the LD pin comparator
Set the following registers (in addition to the normal PLL registers):
•
•
•
•
•
•
•
•
•
•
•
Register 0x018[6:5] = 00b; lock detect counter = five cycles.
Register 0x018[4] = 0b; lock detect window = high range.
Register 0x018[3] = 0b; DLD normal operation.
Register 0x01A[5:0] = 000100b; current source lock detect
mode.
Register 0x01B[7:0] = 0xF7; set REFMON pin to status of
REF1 (active low).
Register 0x01C[2:1] = 11b; enable REF1 and REF2 input
buffers.
Register 0x01D[3] = 1b; enable LD pin comparator.
Register 0x01D[2]=1b; enable the holdover function.
Register 0x01D[1] = 0b; use internal/automatic holdover
mode.
Register 0x01D[0] = 1b; enable the holdover function.
(VCO calibration must be complete before this bit is
enabled.)
Connect REFMON pin to REFSEL pin.
Frequency Status Monitors
The AD9516 contains three frequency status monitors that are
used to indicate if the PLL reference (or references in the case of
single-ended mode) and the VCO have fallen below a threshold
frequency. A diagram showing their location in the PLL is
shown in Figure 54.
The PLL reference frequency monitors have two threshold
frequencies: normal and extended (see Table 16). The reference
frequency monitor thresholds are selected in Register 0x01B[7:5].
Frequency monitor status can be found in Register 0x01F[3:1].
Rev. C | Page 38 of 80
Data Sheet
AD9516-0
REF_SEL
VS
GND
RSET
REFMON
DISTRIBUTION
REFERENCE
REFERENCE
SWITCHOVER
LD
REF1
LOCK
DETECT
PLL
REFERENCE
REF2
CPRSET VCP
STATUS
R
DIVIDER
PROGRAMMABLE
R DELAY
STATUS
REFIN (REF1)
REFIN (REF2)
N DIVIDER
BYPASS
LOW DROPOUT
REGULATOR (LDO)
P, P + 1
PRESCALER
A/B
COUNTERS
LF
PROGRAMMABLE
N DELAY
PHASE
FREQUENCY
DETECTOR
HOLD
CHARGE
PUMP
CP
VCO STATUS
VCO
STATUS
0
DIVIDE BY
2, 3, 4, 5, OR 6
CLK
1
1
06419-070
CLK
0
Figure 54. Reference and VCO Status Monitors
VCO Calibration
The AD9516 on-chip VCO must be calibrated to ensure proper
operation over process and temperature. The VCO calibration
is controlled by a calibration controller running off of a divided
REFIN clock. The calibration requires that the PLL be set up
properly to lock the PLL loop and that the REFIN clock be present.
During the first initialization after a power-up or a reset of the
AD9516, a VCO calibration sequence is initiated by setting
Register 0x018[0] = 1b. This can be done as part of the initial
setup, before executing update registers (Register 0x232[0] = 1b).
Subsequent to the initial setup, a VCO calibration sequence is
initiated by resetting Register 0x018[0] = 0b, executing an update
registers operation, setting Register 0x018[0] = 1b, and executing
another update registers operation. A readback bit, Bit 6 in
Register 0x01F, indicates when a VCO calibration is finished
by returning a logic true (that is, 1b).
The sequence of operations for the VCO calibration is as follows:








Program the PLL registers to the proper values for the PLL
loop. Note that that automatic holdover mode must be
disabled, and the VCO divider must not be set to “Static.”
Ensure that the input reference signal is present.
For the initial setting of the registers after a power-up or reset,
initiate VCO calibration by setting Register 0x018[0] = 1b.
Subsequently, whenever a calibration is desired, set
Register 0x018[0] = 0b, update registers; and then set
Register 0x018[0] = 1b, update registers.
A SYNC operation is initiated internally, causing the
outputs to go to a static state determined by normal SYNC
function operation.
VCO calibrates to the desired setting for the requested
VCO frequency.
Internally, the SYNC signal is released, allowing outputs to
continue clocking.
PLL loop is closed.
PLL locks.
A sync is executed during the VCO calibration; therefore, the
outputs of the AD9516 are held static during the calibration,
which prevents unwanted frequencies from being produced.
However, at the end of a VCO calibration, the outputs may
resume clocking before the PLL loop is completely settled.
The VCO calibration clock divider is set as shown in Table 54
(Register 0x018[2:1]).
The calibration divider divides the PFD frequency (reference
frequency divided by R) down to the calibration clock. The
calibration occurs at the PFD frequency divided by the
calibration divider setting. Lower VCO calibration clock
frequencies result in longer times for a calibration to be
completed.
The VCO calibration clock frequency is given by
fCAL_CLOCK = fREFIN/(R × cal_div)
where:
fREFIN is the frequency of the REFIN signal.
R is the value of the R divider.
cal_div is the division set for the VCO calibration divider
(Register 0x018[2:1]).
The VCO calibration takes 4400 calibration clock cycles.
Therefore, the VCO calibration time in PLL reference clock
cycles is given by
Time to Calibrate VCO =
4400 × R × cal_div PLL Reference Clock Cycles
Table 29. Example Time to Complete a VCO Calibration
with Different fREFIN Frequencies
fREFIN (MHz)
100
10
10
Rev. C | Page 39 of 80
R Divider
1
10
100
PFD
100 MHz
1 MHz
100 kHz
Time to Calibrate VCO
88 μs
8.8 ms
88 ms
AD9516-0
Data Sheet
VCO calibration must be manually initiated. This allows for
flexibility in deciding what order to program registers and when
to initiate a calibration, instead of having it happen every time
certain PLL registers have their values change. For example, this
allows for the VCO frequency to be changed by small amounts
without having an automatic calibration occur each time; this
should be done with caution and only when the user knows that
the VCO control voltage is not going to exceed the nominal best
performance limits. For example, a few 100 kHz steps are fine,
but a few MHz might not be). In addition, because the calibration
procedure results in rapid changes in the VCO frequency, the
distribution section is automatically placed in SYNC until the
calibration is finished. Therefore, this temporary loss of outputs
must be expected.
A VCO calibration should be initiated under the following
conditions:
•
•
After changing any of the PLL R, P, B, and A divider
settings, or after a change in the PLL reference clock
frequency. This, in effect, means any time a PLL register
or reference clock is changed such that a different VCO
frequency results.
Whenever system calibration is desired. The VCO is designed
to operate properly over extremes of temperatures even when
first calibrated at the opposite extreme. However, a VCO
calibration can be initiated at any time, if desired.
CLOCK DISTRIBUTION
A clock channel consists of a pair (or double pair, in the case of
CMOS) of outputs that share a common divider. A clock output
consists of the drivers that connect to the output pins. The clock
outputs have either LVPECL or LVDS/CMOS signal levels at
the pins.
The AD9516 has five clock channels: three channels are LVPECL
(six outputs); two channels are LVDS/CMOS (up to four LVDS
outputs, or up to eight CMOS outputs).
Each channel has its own programmable divider that divides
the clock frequency that is applied to its input. The LVPECL
channel dividers can divide by any integer from 2 to 32, or
the divider can be bypassed to achieve a divide by one. Each
LVDS/CMOS channel divider contains two of these divider
blocks in a cascaded configuration. The total division of the
channel is the product of the divide value of the cascaded dividers.
This allows divide values of (1 to 32) × (1 to 32), or up to 1024
(note that this is not all values from 1 to 1024 but only the set
of numbers that are the product of the two dividers).
Because the internal VCO frequency is above the maximum
channel divider input frequency (1600 MHz), the VCO divider
must be used after the on-chip VCO. The VCO divider can be
set to divide by 2, 3, 4, 5, or 6. External clock signals connected
to the CLK input also require the VCO divider if the frequency
of the signal is greater than 1600 MHz.
The channel dividers allow for a selection of various duty cycles,
depending on the currently set division. That is, for any specific
division, D, the output of the divider can be set to high for N + 1
input clock cycles and low for M + 1 input clock cycles (where
D = N + M + 2). For example, a divide-by-5 can be high for one
divider input cycle and low for four cycles, or a divide-by-5 can
be high for three divider input cycles and low for two cycles.
Other combinations are also possible.
The channel dividers include a duty-cycle correction function,
that can be disabled. In contrast to the selectable duty cycle
just described, this function can correct a non-50% duty cycle
caused by an odd division. However, this requires that the
division be set by M = N + 1.
In addition, the channel dividers allow a coarse phase offset or
delay to be set. Depending on the division selected, the output
can be delayed by up to 31 input clock cycles. The divider
outputs can also be set to start high or start low.
Internal VCO or External CLK as Clock Source
The clock distribution of the AD9516 has two clock input sources:
an internal VCO or an external clock connected to the CLK/
CLK pins. Either the internal VCO or CLK must be chosen as
the source of the clock signal to distribute. When the internal
VCO is selected as the source, the VCO divider must be used.
When CLK is selected as the source, it is not necessary to use
the VCO divider if the CLK frequency is less than the
maximum channel divider input frequency (1600 MHz);
otherwise, the VCO divider must be used to reduce the
frequency to one acceptable by the channel dividers. Table 30
shows how the VCO, CLK, and VCO divider are selected.
Register 0x1E1[1:0] selects the channel divider source and
determines whether the VCO divider is used. It is not possible
to select the VCO without using the VCO divider.
Table 30. Selecting VCO or CLK as Source for Channel
Divider, and Whether VCO Divider Is Used
Register 0x1E1
Bit 1
Bit 0
0
0
0
1
1
0
1
1
Channel Divider Source
CLK
CLK
VCO
Not allowed
VCO Divider
Used
Not used
Used
Not allowed
CLK or VCO Direct to LVPECL Outputs
It is possible to connect either the internal VCO or the CLK
(whichever is selected as the input to the VCO divider) directly
to the LVPECL outputs, OUT0 to OUT5. This configuration
can pass frequencies up to the maximum frequency of the VCO
directly to the LVPECL outputs. The LVPECL outputs may not
be able to provide full voltage swing at the highest frequencies.
Rev. C | Page 40 of 80
Data Sheet
AD9516-0
To connect the LVPECL outputs directly to the internal VCO or
CLK, the VCO divider must be selected as the source to the
distribution section, even if no channel uses it.
Either the internal VCO or the CLK can be selected as the
source for the direct to output routing.
Table 31. Settings for Routing VCO Divider Input Directly
to LVPECL Outputs
Register Setting
0x1E1[1:0] = 00b
0x1E1[1:0] = 10b
0x192[1] = 1b
0x195[1] = 1b
0x198[1] = 1b
Selection
CLK is the source; VCO divider selected
VCO is the source; VCO divider selected
Direct to output OUT0, OUT1
Direct to output OUT2, OUT3
Direct to output OUT4, OUT5
Clock Frequency Division
The total frequency division is a combination of the VCO
divider (when used) and the channel divider. When the VCO
divider is used, the total division from the VCO or CLK to the
output is the product of the VCO divider (2, 3, 4, 5, 6) and the
division of the channel divider. Table 32 and Table 33 indicate
how the frequency division for a channel is set. For the LVPECL
outputs, there is only one divider per channel. For the LVDS/
CMOS outputs, there are two dividers (X.1, X.2) cascaded
per channel.
Table 32. Frequency Division for Divider 0 to Divider 2
CLK
or VCO
Selected
CLK/VCO
CLK/VCO
CLK/VCO
VCO
Divider
2 to 6
2 to 6
2 to 6
Channel
Divider
1 (bypassed)
1 (bypassed)
2 to 32
Direct to
Output
Yes
No
No
CLK
CLK
Not used
Not used
1 (bypassed)
2 to 32
No
No
Frequency
Division
1
(2 to 6) × (1)
(2 to 6) ×
(2 to 32)
1
2 to 32
Table 33. Frequency Division for Divider 3 and Divider 4
CLK
or VCO
Selected
CLK/VCO
VCO
Divider
2 to 6
CLK/VCO
2 to 6
CLK/VCO
2 to 6
Channel Divider
X.1
X.2
1
1
(bypassed) (bypassed)
2 to 32
1
(bypassed)
2 to 32
2 to 32
CLK
CLK
CLK
Not used
Not used
Not used
1
2 to 32
2 to 32
1
1
2 to 32
Frequency
Division
(2 to 6) ×
(1) × (1)
(2 to 6) ×
(2 to 32) × (1)
(2 to 6) ×
(2 to 32) ×
(2 to 32)
1
(2 to 32) × (1)
2 to 32 ×
(2 to 32)
The channel dividers feeding the LVPECL output drivers
contain one 2-to-32 frequency divider. This divider provides for
division by 2 to 32. Division by 1 is accomplished by bypassing
the divider. The dividers also provide for a programmable duty
cycle, with optional duty-cycle correction when the divide ratio
is odd. A phase offset or delay in increments of the input clock
cycle is selectable. The channel dividers operate with a signal at
their inputs up to 1600 MHz. The features and settings of the
dividers are selected by programming the appropriate setup
and control registers (see Table 52 through Table 62).
VCO Divider
The VCO divider provides frequency division between
the internal VCO or the external CLK input and the clock
distribution channel dividers. The VCO divider can be set
to divide by 2, 3, 4, 5, or 6 (see Table 60, Register 0x1E0[2:0]).
Channel Dividers—LVPECL Outputs
Each pair of LVPECL outputs is driven by a channel divider.
There are three channel dividers (0, 1, and 2) driving a total of
six LVPECL outputs (OUT0 to OUT5). Table 34 lists the register
locations used for setting the division and other functions of
these dividers. The division is set by the values of M and N. The
divider can be bypassed (equivalent to divide-by-1, divider circuit
is powered down) by setting the bypass bit. The duty-cycle
correction can be enabled or disabled according to the setting
of the DCCOFF bits.
Table 34. Setting DX for Divider 0, Divider 1, and Divider 21
Divider
0
1
2
1
Low Cycles
M
0x190[7:4]
0x193[7:4]
0x196[7:4]
High Cycles
N
0x190[3:0]
0x193[3:0]
0x196[3:0]
Bypass
0x191[7]
0x194[7]
0x197[7]
DCCOFF
0x192[0]
0x195[0]
0x198[0]
Note that the value stored in the register = # of cycles minus 1.
Channel Frequency Division (0, 1, and 2)
For each channel (where the channel number is x: 0, 1, or 2),
the frequency division, DX, is set by the values of M and N
(four bits each, representing Decimal 0 to Decimal 15), where
Number of Low Cycles = M + 1
Number of High Cycles = N + 1
The cycles are cycles of the clock signal currently routed to the
input of the channel dividers (VCO divider out or CLK).
When a divider is bypassed, DX = 1.
Otherwise, DX = (N + 1) + (M + 1) = N + M + 2. This allows
each channel divider to divide by any integer from 2 to 32.
Rev. C | Page 41 of 80
AD9516-0
Data Sheet
Duty Cycle and Duty-Cycle Correction (0, 1, and 2)
Table 36. Duty Cycle with VCO Divider, Input Duty Cycle Is X%
The duty cycle of the clock signal at the output of a channel is
a result of some or all of the following conditions:
VCO
Divider
•
•
•
•
Even
What are the M and N values for the channel?
Is the DCC enabled?
Is the VCO divider used?
What is the CLK input duty cycle? (The internal VCO has
a 50% duty cycle.)
The DCC function is enabled by default for each channel divider.
However, the DCC function can be disabled individually for
each channel divider by setting the DCCOFF bit for that channel.
Certain M and N values for a channel divider result in a non-50%
duty cycle. A non-50% duty cycle can also result with an even
division, if M ≠ N. The duty-cycle correction function
automatically corrects non-50% duty cycles at the channel
divider output to 50% duty cycle. Duty-cycle correction
requires the following channel divider conditions:
•
•
An even division must be set as M = N
An odd division must be set as M = N + 1
When not bypassed or corrected by the DCC function, the duty
cycle of each channel divider output is the numerical value of
(N + 1)/(N + M + 2), expressed as a percentage (%).
The duty cycle at the output of the channel divider for various
configurations is shown in Table 35 to Table 37.
Table 35. Duty Cycle with VCO Divider, Input Duty Cycle Is 50%
VCO
Divider
Even, Odd
DX
N+M+2
1 (divider
bypassed)
1 (divider
bypassed)
1 (divider
bypassed)
Even
Even, Odd
Odd
Even
Odd = 3
Odd = 5
Output Duty Cycle
DCCOFF = 1 DCCOFF = 0
50%
50%
33.3%
50%
40%
50%
(N + 1)/
(N + M + 2)
(N + 1)/
(N + M + 2)
50%; requires M = N
50%; requires M = N + 1
Odd = 3
Odd = 5
Even
DX
N+M+2
1 (divider
bypassed)
1 (divider
bypassed)
1 (divider
bypassed)
Even
Odd
Odd = 3
Even
Odd = 3
Odd
Odd = 5
Even
Odd = 5
Odd
Output Duty Cycle
DCCOFF = 1
DCCOFF = 0
50%
50%
33.3%
(1 + X%)/3
40%
(2 + X%)/5
(N + 1)/
(N + M + 2)
(N + 1)/
(N + M + 2)
(N + 1)/
(N + M + 2)
(N + 1)/
(N + M + 2)
(N + 1)/
(N + M + 2)
(N + 1)/
(N + M + 2)
50%,
requires M = N
50%,
requires M = N + 1
50%,
requires M = N
(3N + 4 + X%)/(6N + 9),
requires M = N + 1
50%,
requires M = N
(5N + 7 + X%)/(10N + 15),
requires M = N + 1
Table 37. Channel Divider Output Duty Cycle When the
VCO Divider Is Not Used
Input
Clock
Duty
Cycle
Any
DX
N+M+2
1
Any
Even
50%
Odd
X%
Odd
Output Duty Cycle
DCCOFF = 1
1 (divider
bypassed)
(N + 1)/
(M + N + 2)
(N + 1)/
(M + N + 2)
(N + 1)/
(M + N + 2)
DCCOFF = 0
Same as input
duty cycle
50%, requires M = N
50%, requires
M=N+1
(N + 1 + X%)/(2 × N + 3),
requires M = N + 1
The internal VCO has a duty cycle of 50%. Therefore, when the
VCO is connected directly to the output, the duty cycle is 50%.
If the CLK input is routed directly to the output, the duty cycle of
the output is the same as the CLK input.
Rev. C | Page 42 of 80
Data Sheet
AD9516-0
Phase Offset or Coarse Time Delay (0, 1, and 2)
Channel Dividers—LVDS/CMOS Outputs
Each channel divider allows for a phase offset, or a coarse time
delay, to be programmed by setting register bits (see Table 38).
These settings determine the number of cycles (successive
rising edges) of the channel divider input frequency by which to
offset or delay the rising edge of the output of the divider. This
delay is with respect to a nondelayed output (that is, with a
phase offset of zero). The amount of the delay is set by five bits
loaded into the phase offset (PO) register, plus the start high
(SH) bit for each channel divider. When the start high bit is set,
the delay is also affected by the number of low cycles (M) that
are programmed for the divider.
Channel Divider 3 and Channel Divider 4 each drive a pair of
LVDS outputs, giving a total of four LVDS outputs (OUT6 to
OUT9). Alternatively, each of these LVDS differential outputs
can be configured individually as a pair (A and B) of CMOS
single-ended outputs, providing for up to eight CMOS outputs.
By default, the B output of each pair is off but can be turned on
as desired.
The SYNC function must be used to make phase offsets effective
(see the Synchronizing the Outputs—SYNC Function section).
Table 38. Setting Phase Offset and Division for Divider 0,
Divider 1, and Divider 2
Divider
0
1
2
Start
High (SH)
0x191[4]
0x194[4]
0x197[4]
Phase
Offset (PO)
0x191[3:0]
0x194[3:0]
0x197[3:0]
Low
Cycles (M)
0x190[7:4]
0x193[7:4]
0x196[7:4]
High
Cycles (N)
0x190[3:0]
0x193[3:0]
0x196[3:0]
Channel Divider 3 and Channel Divider 4 each consist of two
cascaded, 2 to 32, frequency dividers. The channel frequency
division is DX.1 × DX.2 or up to 1024. Divide-by-1 is achieved by
bypassing one or both of these dividers. Both of the dividers
also have DCC enabled by default, but this function can be
disabled, if desired, by setting the DCCOFF bit of the channel.
A coarse phase offset or delay is also programmable (see the
Phase Offset or Coarse Time Delay (Divider 3 and Divider 4)
section). The channel dividers operate up to 1600 MHz. The
features and settings of the dividers are selected by programming
the appropriate setup and control registers (see Table 52 and
Table 53 through Table 62).
Table 39. Setting Division (DX) for Divider 3, Divider 41
Let
Δt = delay (in seconds).
Δc = delay (in cycles of clock signal at input to DX).
TX = period of the clock signal at the input of the divider, DX
(in seconds).
Φ = 16 × SH[4] + 8 × PO[3] + 4 × PO[2] + 2 × PO[1] + 1 × PO[0]
Divider
3
3.1
3.2
4
4.1
4.2
The channel divide-by is set as N = high cycles, and M = low cycles.
Channel Frequency Division (Divider 3 and Divider 4)
Case 1
The division for each channel divider is set by the bits in the
registers for the individual dividers (X.Y = 3.1, 3.2, 4.1, and 4.2)
1
For Φ ≤ 15:
Δt = Φ × TX
Δc = Δt/TX = Φ
Note that the value stored in the register = # of cycles minus 1.
When only X.2 is bypassed, DX = (NX.1 + MX.1 + 2) × 1.
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15
CHANNEL
DIVIDER INPUT
Tx
2 × Tx
By cascading the dividers, channel division up to 1024 can be
obtained. However, not all integer value divisions from 1 to
1024 are obtainable; only the values that are the product of the
separate divisions of the two dividers (DX.1 × DX.2) can be realized.
06419-071
1 × Tx
When both X.1 and X.2 are not bypassed, DX = (NX.1 + MX.1 + 2) ×
(NX.2 + MX.2 + 2).
If only one divider is needed when using Divider 3 and Divider 4,
use the first one (X.1) and bypass the second one (X.2). Do not
bypass X.1 and use X.2.
CHANNEL DIVIDER OUTPUTS
DIV = 4, DUTY = 50%
SH = 0
DIVIDER 0 PO = 0
SH = 0
PO = 2
DCCOFF
0x19D[0]
0x19D[0]
0x1A2[0]
0x1A2[0]
When both X.1 and X.2 are bypassed, DX = 1 × 1 = 1.
By giving each divider a different phase offset, output-to-output
delays can be set in increments of the channel divider input
clock cycle. Figure 55 shows the results of setting such a coarse
offset between outputs.
DIVIDER 2
Bypass
0x19C[4]
0x19C[5]
0x1A1[4]
0x1A1[5]
Number of High Cycles = NX.Y + 1
For Φ ≥ 16:
Δt = (Φ − 16 + M + 1) × TX
Δc = Δt/TX
SH = 0
PO = 1
N
0x199[3:0]
0x19B[3:0]
0x19E[3:0]
0x1A0[3:0]
Number of Low Cycles = MX.Y + 1
Case 2
DIVIDER 1
M
0x199[7:4]
0x19B[7:4]
0x19E[7:4]
0x1A0[7:4]
Figure 55. Effect of Coarse Phase Offset (or Delay)
Rev. C | Page 43 of 80
AD9516-0
Data Sheet
Duty Cycle and Duty-Cycle Correction (Divider 3 and
Divider 4)
The same duty cycle and DCC considerations apply to Divider 3
and Divider 4 as to Divider 0, Divider 1, and Divider 2 (see the
Duty Cycle and Duty-Cycle Correction (0, 1, and 2) section);
however, with these channel dividers, the number of possible
configurations is even more complex.
Duty-cycle correction on Divider 3 and Divider 4 requires the
following channel divider conditions:
•
•
•
•
An even DX.Y must be set as MX.Y = NX.Y (low cycles = high
cycles).
An odd DX.Y must be set as MX.Y = NX.Y + 1 (the number of
low cycles must be one greater than the number of high
cycles).
If only one divider is bypassed, it must be the second
divider, X.2.
If only one divider has an even divide by, it must be the
second divider, X.2.
The possibilities for the duty cycle of the output clock from
Divider 3 and Divider 4 are shown in Table 40 through Table 44.
Table 40. Divider 3, Divider 4 Duty Cycle; VCO Divider
Used; Duty Cycle Correction Off (DCCOFF = 1)
VCO
Divider
Even
Odd = 3
Odd = 5
Even
DX.1
NX.1 + MX.1 + 2
1
1
1
Even, odd
DX.2
NX.2 + MX.2 + 2
1
1
1
1
Odd
Even, odd
1
Even
Even, odd
Even, odd
Odd
Even, odd
Even, odd
Output Duty
Cycle
50%
33.3%
40%
(NX.1 + 1)/
(NX.1 + MX.1 + 2)
(NX.1 + 1)/
(NX.1 + MX.1 + 2)
(NX.2 + 1)/
(NX.2 + MX.2 + 2)
(NX.2 + 1)/
(NX.2 + MX.2 + 2)
Table 41. Divider 3, Divider 4 Duty Cycle; VCO Divider Not
Used; Duty Cycle Correction Off (DCCOFF = 1)
Input Clock
Duty Cycle
50%
X%
50%
DX.1
NX.1 + MX.1 + 2
1
1
Even, odd
DX.2
NX.2 + MX.2 + 2
1
1
1
X%
Even, odd
1
50%
Even, odd
Even, odd
X%
Even, odd
Even, odd
Output
Duty Cycle
50%
X%
(NX.1 + 1)/
(NX.1 + MX.1 + 2)
(NX.1 + 1)/
(NX.1 + MX.1 + 2)
(NX.2 + 1)/
(NX.2 + MX.2 + 2)
(NX.2 + 1)/
(NX.2 + MX.2 + 2)
Table 42. Divider 3, Divider 4 Duty Cycle; VCO Divider
Used; Duty Cycle Correction Is On (DCCOFF = 0); VCO
Divider Input Duty Cycle = 50%
VCO
Divider
Even
Odd
Even
Odd
Even
Odd
Even
Odd
Even
Odd
Even
Odd
DX.1
DX.2
NX.1 + MX.1 + 2
1
1
Even (NX.1 = MX.1)
Even (NX.1 = MX.1)
Odd (MX.1 = NX.1 + 1)
Odd (MX.1 = NX.1 + 1)
Even (NX.1 = MX.1)
Even (NX.1 = MX.1)
Odd (MX.1 = NX.1 + 1)
Odd (MX.1 = NX.1 + 1)
Odd (MX.1 = NX.1 + 1)
Odd (MX.1 = NX.1 + 1)
NX.2 + MX.2 + 2
1
1
1
1
1
1
Even (NX.2 = MX.2)
Even (NX.2 = MX.2)
Even (NX.2 = MX.2)
Even (NX.2 = MX.2)
Odd (MX.2 = NX.2 + 1)
Odd (MX.2 = NX.2 + 1)
Output
Duty Cycle
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
Table 43. Divider 3, Divider 4 Duty Cycle; VCO Divider
Used; Duty Cycle Correction On (DCCOFF = 0); VCO
Divider Input Duty Cycle = X%
VCO
Divider
Even
Odd = 3
Odd = 5
Even
Odd
Even
Odd = 3
Odd = 5
Even
Odd
Even
Odd
Even
DX.1
DX.2
NX.1 + MX.1 + 2
1
1
1
Even
(NX.1 = MX.1)
Even
(NX.1 = MX.1)
Odd
(MX.1 = NX.1 + 1)
Odd
(MX.1 = NX.1 + 1)
Odd
(MX.1 = NX.1 + 1)
Even
(NX.1 = MX.1)
Even
(NX.1 = MX.1)
Odd
(MX.1 = NX.1 + 1)
Odd
(MX.1 = NX.1 + 1)
Odd
(MX.1 = NX.1 + 1)
NX.2 + MX.2 + 2
1
1
1
Output
Duty Cycle
50%
(1 + X%)/3
(2 + X%)/5
1
50%
1
50%
1
50%
Odd
(MX.1 = NX.1 + 1)
Odd
(MX.2 = NX.2 + 1)
Odd
(MX.1 = NX.1 + 1)
Odd
(MX.2 = NX.2 + 1)
1
1
Even
(NX.2 = MX.2)
Even
(NX.2 = MX.2)
Even
(NX.2 = MX.2)
Even
(NX.2 = MX.2)
Odd
(MX.2 = NX.2 + 1)
Odd = 3
Odd = 5
Rev. C | Page 44 of 80
(3NX.1 + 4 + X%)/
(6NX.1 + 9)
(5NX.1 + 7 + X%)/
(10NX.1 + 15)
50%
50%
50%
50%
50%
(6NX.1NX.2 + 9NX.1 +
9NX.2 + 13 + X%)/
(3(2NX.1 + 3)
(2NX.2 + 3))
(10NX.1NX.2 + 15NX.1 +
15NX.2 + 22 + X%)/
(5(2 NX.1 + 3)
(2 NX.2 + 3))
Data Sheet
AD9516-0
Table 44. Divider 3, Divider 4 Duty Cycle; VCO Divider Not
Used; Duty Cycle Correction On (DCCOFF = 0)
X%
X%
50%
X%
50%
X%
50%
X%
50%
X%
DX.1
DX.2
NX.1 + MX.1 + 2
1
Even
(NX.1 = MX.1)
1
Even
(NX.1 = MX.1)
Odd
(MX.1 = NX.1 + 1)
Odd
(MX.1 = NX.1 + 1)
Odd
(MX.1 = NX.1 + 1)
Even
(NX.1 = MX.1)
Even
(NX.1 = MX.1)
Odd
(MX.1 = NX.1 + 1)
Odd
(MX.1 = NX.1 + 1)
Odd
(MX.1 = NX.1 + 1)
Odd
(MX.1 = NX.1 + 1)
NX.2 + MX.2 + 2
1
1
Output
Duty Cycle
50%
50%
1
1
X% (High)
50%
Case 2
1
50%
When Φx.1 ≤ 15 and Φx.2 ≥ 16:
1
(NX.1 + 1 + X%)/
(2NX.1 + 3)
(NX.1 + 1 + X%)/
(2NX.1 + 3)
50%
1
Even
(NX.2 = MX.2)
Even
(NX.2 = MX.2)
Even
(NX.2 = MX.2)
Even
(NX.2 = MX.2)
Odd
(MX.2 = NX.2 + 1)
Odd
(MX.2 = NX.2 + 1)
Case 1
When Φx.1 ≤ 15 and Φx.2 ≤ 15:
Δt = Φx.1 × TX.1 + ΦX.2 × Tx.2
Δt = ΦX.1 × TX.1 + (ΦX.2 − 16 + MX.2 + 1) × TX.2
Case 3
When ΦX.1 ≥ 16 and ΦX.2 ≤ 15:
Δt = (ΦX.1 − 16 + MX.1 + 1) × TX.1 + ΦX.2 × TX.2
Case 4
50%
When ΦX.1 ≥ 16 and ΦX.2 ≥ 16:
50%
Δt =
(ΦX.1 − 16 + MX.1 + 1) × TX.1 + (ΦX.2 − 16 + MX.2 + 1) × TX.2
50%
Fine Delay Adjust (Divider 3 and Divider 4)
50%
(2NX.1NX.2 + 3NX.1 +
3NX.2 + 4 + X%)/
((2NX.1 + 3)(2NX.2 + 3))
Each AD9516 LVDS/CMOS output (OUT6 to OUT9) includes
an analog delay element that can be programmed to give
variable time delays (Δt) in the clock signal at that output.
BYPASS
VCO
CLK DIVIDER
CMOS
Phase Offset or Coarse Time Delay (Divider 3 and Divider 4)
Divider 3 and Divider 4 can be set to have a phase offset or
delay. The phase offset is set by a combination of the bits in the
phase offset and start high registers (see Table 45).
DIVIDER
X.1
Start
High (SH)
0x19C[0]
0x19C[1]
0x1A1[0]
0x1A1[1]
Phase
Offset (PO)
0x19A[3:0]
0x19A[7:4]
0x19F[3:0]
0x19F[7:4]
Low
Cycles M
0x199[7:4]
0x19B[7:4]
0x19E[7:4]
0x1A0[7:4]
High
Cycles N
0x199[3:0]
0x19B[3:0]
0x19E[3:0]
0x1A0[3:0]
LVDS
FINE DELAY
ADJUST
CMOS
OUTM
OUTM
OUTPUT
DRIVERS
DIVIDER
X.2
BYPASS
CMOS
Table 45. Setting Phase Offset and Division for Divider 3 and
Divider 4
Divider
3 3.1
3.2
4 4.1
4.2
Δt
Δt
LVDS
FINE DELAY
ADJUST
CMOS
OUTN
OUTN
06419-072
Input
Clock
Duty
Cycle
50%
50%
Let Δt = delay (in seconds).
Φx.y = 16 × SH[0] + 8 × PO[3] + 4 × PO[2] + 2 × PO[1] +
1 × PO[0].
TX.1 = period of the clock signal at the input to DX.1 (in seconds).
TX.2 = period of the clock signal at the input to DX.2 (in seconds).
Figure 56. Fine Delay (OUT6 to OUT9)
The amount of delay applied to the clock signal is determined
by programming four registers per output (see Table 46).
Table 46. Setting Analog Fine Delays
OUTPUT
(LVDS/CMOS)
OUT6
OUT7
OUT8
OUT9
Rev. C | Page 45 of 80
Ramp
Capacitors
0x0A1[5:3]
0x0A4[5:3]
0x0A7[5:3]
0x0AA[5:3]
Ramp
Current
0x0A1[2:0]
0x0A4[2:0]
0x0A7[2:0]
0x0AA[2:0]
Delay
Fraction
0x0A2[5:0]
0x0A5[5:0]
0x0A8[5:0]
0x0AB[5:0]
Delay
Bypass
0x0A0[0]
0x0A3[0]
0x0A6[0]
0x0A9[0]
AD9516-0
Data Sheet
Calculating the Fine Delay
Synchronization of the outputs is executed in several ways,
as follows:
The following values and equations are used to calculate the
delay of the delay block.
•
IRAMP (µA) = 200 × (Ramp Current + 1)
•
Number of Capacitors = Number of Bits =
0 in Ramp Capacitors + 1
Example: 101 = 1 + 1 = 2; 110 = 1 + 1 = 2; 100 = 2 + 1 = 3;
001 = 2 + 1 = 3; 111 = 0 + 1 = 1.
•
Delay Range (ns) = 200 × ((No. of Caps + 3)/(IRAMP)) × 1.3286
 No.of Caps − 1 
×6
Offset (ns ) = 0.34 + (1600 − I RAMP )× 10 −4 + 

I RAMP


Delay Full Scale (ns) = Delay Range + Offset
•
•
•
Fine Delay (ns) =
Delay Range × Delay Fraction × (1/63) + Offset
Note that only delay fraction values up to 47 decimal (101111b;
0x2F) are supported.
In no case can the fine delay exceed one-half of the output clock
period. If a delay longer than half of the clock period is attempted,
the output stops clocking.
The delay function adds some jitter that is greater than that
specified for the nondelayed output. This means that the delay
function should be used primarily for clocking digital chips,
such as FPGA, ASIC, DUC, and DDC. An output with this
delay enabled may not be suitable for clocking data converters.
The jitter is higher for long full scales because the delay block
uses a ramp and trip points to create the variable delay. A slower
ramp time produces more time jitter.
Synchronizing the Outputs—SYNC Function
The AD9516 clock outputs can be synchronized to each other.
Outputs can be individually excluded from synchronization.
Synchronization consists of setting the nonexcluded outputs to
a preset set of static conditions and, subsequently, releasing
these outputs to continue clocking at the same instant with the
preset conditions applied. This allows for the alignment of the
edges of two or more outputs or for the spacing of edges,
according to the coarse phase offset settings for two or more
outputs.
By forcing the SYNC pin low and then releasing it (manual
sync).
By setting and then resetting any one of the following three
bits: the soft sync bit (Register 0x230[0]), the soft reset bit
(Register 0x000[2] [mirrored]), and the power-down
distribution reference bit (Register 0x230[1]).
By executing synchronization of the outputs as part of the
chip power-up sequence.
By forcing the RESET pin low and then releasing it (chip
reset).
By forcing the PD pin low and then releasing it (chip powerdown).
Following completion of a VCO calibration. An internal
SYNC signal is automatically asserted at the beginning and
released upon the completion of a VCO calibration.
The most common way to execute the SYNC function is to use
the SYNC pin to do a manual synchronization of the outputs.
This requires a low-going signal on the SYNC pin, which is held
low and then released when synchronization is desired. The
timing of the SYNC operation is shown in Figure 57 (using
VCO divider) and Figure 58 (VCO divider not used). There is
an uncertainty of up to one cycle of the clock at the input to the
channel divider due to the asynchronous nature of the SYNC
signal with respect to the clock edges inside the AD9516. The
delay from the SYNC rising edge to the beginning of synchronized
output clocking is between 14 and 15 cycles of clock at the
channel divider input, plus either one cycle of the VCO divider
input (see Figure 57) or one cycle of the channel divider input
(see Figure 58), depending on whether the VCO divider is used.
Cycles are counted from the rising edge of the signal.
Another common way to execute the SYNC function is by
setting and resetting the soft sync bit at Register 0x230[0] (see
Table 53 through Table 62 for details). Both setting and
resetting of the soft sync bit require an update all registers
operation (Register 0x232[0] = 1) to take effect.
Rev. C | Page 46 of 80
Data Sheet
AD9516-0
CHANNEL DIVIDER
OUTPUT CLOCKING
CHANNEL DIVIDER
OUTPUT CLOCKING
CHANNEL DIVIDER OUTPUT STATIC
INPUT TO VCO DIVIDER
1
1
INPUT TO CHANNEL DIVIDER
2
3
4
5
6
7
8
9
10
11
12
13
14
SYNC PIN
OUTPUT OF
CHANNEL DIVIDER
06419-073
14 TO 15 CYCLES AT CHANNEL DIVIDER INPUT + 1 CYCLE AT VCO DIVIDER INPUT
Figure 57. SYNC Timing When VCO Divider Is Used—CLK or VCO Is Input
CHANNEL DIVIDER
OUTPUT CLOCKING
CHANNEL DIVIDER
OUTPUT CLOCKING
CHANNEL DIVIDER OUTPUT STATIC
INPUT TO CLK
IINPUT TO CHANNEL DIVIDER
1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
SYNC PIN
OUTPUT OF
CHANNEL DIVIDER
06419-074
14 TO 15 CYCLES AT CHANNEL DIVIDER INPUT + 1 CYCLE AT CLK INPUT
Figure 58. SYNC Timing When VCO Divider Is Not Used—CLK Input Only
A sync operation brings all outputs that have not been excluded
(by the nosync bit) to a preset condition before allowing the
outputs to begin clocking in synchronicity. The preset condition
takes into account the settings in each of the channel’s start high
bit and its phase offset. These settings govern both the static
state of each output when the SYNC operation is happening and
the state and relative phase of the outputs when they begin
clocking again upon completion of the SYNC operation.
Between outputs and after synchronization, this allows for the
setting of phase offsets.
The AD9516 outputs are in pairs, sharing a channel divider per
pair (two pairs of pairs, four outputs, in the case of CMOS). The
synchronization conditions apply to both outputs of a pair.
Each channel (a divider and its outputs) can be excluded from
any sync operation by setting the nosync bit of the channel.
Channels that are set to ignore SYNC (excluded channels) do
not set their outputs static during a sync operation, and their
outputs are not synchronized with those of the nonexcluded
channels.
Clock Outputs
The AD9516 offers three different output level choices:
LVPECL, LVDS, and CMOS. OUT0 to OUT5 are LVPECL
differential outputs; and OUT6 to OUT9 are LVDS/CMOS
outputs. These outputs can be configured as either LVDS
differential or as pairs of single-ended CMOS outputs.
Rev. C | Page 47 of 80
AD9516-0
Data Sheet
LVPECL Outputs—OUT0 to OUT5
3.5mA
The LVPECL differential voltage (VOD) is selectable from ~400 mV
to ~960 mV (see Register 0x0F0[3:2] to Register 0x0F5[3:2]).
The LVPECL outputs have dedicated pins for power supply
(VS_LVPECL), allowing a separate power supply to be used.
VS_LVPECL can be from 2.5 V to 3.3 V.
OUT
06419-034
The LVPECL output polarity can be set as noninverting or
inverting, which allows for the adjustment of the relative
polarity of outputs within an application without requiring a
board layout change. Each LVPECL output can be powered
down or powered up, as needed. Because of the architecture of
the LVPECL output stages, there is the possibility of electrical
overstress and breakdown under certain power-down conditions.
For this reason, the LVPECL outputs have several power-down
modes. This includes a safe power-down mode that continues
to protect the output devices while powered down, although it
consumes somewhat more power than a total power-down. If
the LVPECL output pins are terminated, it is best to select the
safe power-down mode. If the pins are not connected (unused),
it is acceptable to use the total power-down mode.
OUT
3.5mA
Figure 60. LVDS Output Simplified Equivalent Circuit with
3.5 mA Typical Current Source
Each LVDS/CMOS output can be powered down as needed to
save power. The CMOS output power-down is controlled by the
same bit that controls the LVDS power-down for that output.
This power-down control affects both CMOS Output A and
CMOS Output B. However, when CMOS Output A is powered up,
CMOS Output B can be powered on or off separately.
VS
3.3V
06419-035
OUT1/
OUT1
OUT
Figure 61. CMOS Equivalent Output Circuit
OUT
RESET MODES
The AD9516 has several ways to force the chip into a reset
condition that restores all registers to their default values and
makes these settings active.
Power-On Reset—Start-Up Conditions When VS Is
Applied
06419-033
GND
Figure 59. LVPECL Output, Simplified Equivalent Circuit
LVDS/CMOS Outputs—OUT6 to OUT9
OUT6 to OUT9 can be configured as either an LVDS
differential output or as a pair of CMOS single-ended outputs.
The LVDS outputs allow for selectable output current from
~1.75 mA to ~7 mA.
The LVDS output polarity can be set as noninverting or
inverting, which allows for the adjustment of the relative
polarity of outputs within an application without requiring a
board layout change. Each LVDS output can be powered down
if not needed to save power.
OUT6 to OUT9 can also be CMOS outputs. Each LVDS output
can be configured to be two CMOS outputs. This provides for
up to eight CMOS outputs: OUT6A, OUT6B, OUT7A, OUT7B,
OUT8A, OUT8B, OUT9A, and OUT9B. When an output is
configured as CMOS, CMOS Output A is automatically turned on.
CMOS Output B can be turned on or off independently. The
relative polarity of the CMOS outputs can also be selected for any
combination of inverting and noninverting (see Table 57 for
Register 0x140[7:5], Register 0x141[7:5], Register 0x142[7:5],
and Register 0x143[7:5]).
A power-on reset (POR) is issued when the VS power supply is
turned on. This initializes the chip to the power-on conditions
that are determined by the default register settings. These are
indicated in the Default Value (Hex) column of Table 52. At
power-on, the AD9516 also executes a SYNC operation, which
brings the outputs into phase alignment according to the default
settings.
Asynchronous Reset via the RESET Pin
An asynchronous hard reset is executed by momentarily pulling
RESET low. A reset restores the chip registers to the default settings.
Soft Reset via Register 0x000[2]
A soft reset is executed by writing Register 0x000[2] and
Register 0x000[5] = 1b. This bit is not self-clearing; it must be
cleared by writing Register 0x000[2] and Register 0x000[5] = 0b to
reset it and complete the soft reset operation. A soft reset restores
the default values to the internal registers. The soft reset bit does
not require an update registers command (Register 0x232) to be
issued.
Rev. C | Page 48 of 80
Data Sheet
AD9516-0
POWER-DOWN MODES
In asynchronous power-down mode, the device powers down
as soon as the registers are updated.
Chip Power-Down via PD
The AD9516 can be put into a power-down condition by
pulling the PD pin low. Power-down turns off most of the
functions and currents inside the AD9516. The chip remains in
this power-down state until PD is brought back to logic high.
When the AD9516 wakes up, it returns to the settings programmed
into its registers prior to the power-down, unless the registers
are changed by new programming while the PD pin is held low.
The PD power-down shuts down the currents on the chip, except
the bias current that is necessary to maintain the LVPECL
outputs in a safe shutdown mode. This is needed to protect the
LVPECL output circuitry from damage that could be caused by
certain termination and load configurations when tristated.
Because this is not a complete power-down, it can be called
sleep mode.
The PLL is off (asynchronous power-down).
The VCO is off.
The CLK input buffer is off.
All dividers are off.
All LVDS/CMOS outputs are off.
All LVPECL outputs are in safe off mode.
The serial control port is active, and the chip responds
to commands.
If the AD9516 clock outputs must be synchronized to each
other, a SYNC is required upon exiting power-down (see the
Synchronizing the Outputs—SYNC Function section). A VCO
calibration is not required when exiting power-down.
PLL Power-Down
The PLL section of the AD9516 can be selectively powered
down. There are three PLL operating modes that are set by
Register 0x010[1:0], as shown in Table 54.
Distribution Power-Down
The distribution section can be powered down by writing
Register 0x230[1] = 1b. This turns off the bias to the distribution
section. If the LVPECL power-down mode is normal operation
(00b), it is possible for a low impedance load on that LVPECL
output to draw significant current during this power-down.
If the LVPECL power-down mode is set to 11b, the LVPECL
output is not protected from reverse bias and may be damaged
under certain termination conditions.
Individual Clock Output Power-Down
Any of the clock distribution outputs can be powered down
individually by writing to the appropriate registers. The register
map details the individual power-down settings for each output
(see Table 52). The LVDS/CMOS outputs can be powered
down, regardless of their output load configuration.
When the AD9516 is in a PD power-down, the chip is in the
following state:
•
•
•
•
•
•
•
In synchronous power-down mode, the PLL power-down is
gated by the charge pump to prevent unwanted frequency
jumps. The device goes into power-down on the occurrence
of the next charge pump event after the registers are updated.
The LVPECL outputs have multiple power-down modes
(see Table 56), which give some flexibility in dealing with the
various output termination conditions. When the mode is set to
10b, the LVPECL output is protected from reverse bias to
2 VBE + 1 V. If the mode is set to 11b, the LVPECL output is
not protected from reverse bias and can be damaged under
certain termination conditions. This setting also affects the
operation when the distribution block is powered down with
Register 0x230[1] = 1b (see the Distribution Power-Down section).
Individual Circuit Block Power-Down
Other AD9516 circuit blocks (such as CLK, REF1, and REF2)
can be powered down individually. This gives flexibility in
configuring the part for power savings whenever certain chip
functions are not needed.
Rev. C | Page 49 of 80
AD9516-0
Data Sheet
SERIAL CONTROL PORT
The AD9516 serial control port is a flexible, synchronous, serial
communications port that allows an easy interface with many
industry-standard microcontrollers and microprocessors. The
AD9516 serial control port is compatible with most synchronous
transfer formats, including both the Motorola SPI® and Intel®
SSR® protocols. The serial control port allows read/write access
to all registers that configure the AD9516. Single or multiple
byte transfers are supported, as well as MSB first or LSB first
transfer formats. The AD9516 serial control port can be
configured for a single bidirectional I/O pin (SDIO only) or
for two unidirectional I/O pins (SDIO/SDO). By default, the
AD9516 is in bidirectional mode, long instruction (long
instruction is only instruction mode supported).
SERIAL CONTROL PORT PIN DESCRIPTIONS
SCLK (serial clock) is the serial shift clock. This pin is an input.
SCLK is used to synchronize serial control port reads and
writes. Write data bits are registered on the rising edge of this
clock, and read data bits are registered on the falling edge. This
pin is internally pulled down by a 30 kΩ resistor to ground.
SDIO (serial data input/output) is a dual-purpose pin that acts
as either an input only (unidirectional mode) or as both an
input/output (bidirectional mode). The AD9516 defaults to the
bidirectional I/O mode (Register 0x000[0] = 0b).
SDO (serial data out) is used only in the unidirectional I/O
mode (Register 0x000[0] = 1b) as a separate output pin for
reading back data.
CS (chip select bar) is an active low control that gates the read
and write cycles. When CS is high, SDO and SDIO are in a high
impedance state. This pin is internally pulled up by a 30 kΩ
resistor to VS.
16
CS
17
SDO
21
SDIO
22
AD9516-0
SERIAL
CONTROL
PORT
06419-036
SCLK
Figure 62. Serial Control Port
GENERAL OPERATION OF SERIAL CONTROL PORT
A write or a read operation to the AD9516 is initiated by pulling
CS low.
CS stall high is supported in modes where three or fewer bytes
of data (plus instruction data) are transferred (see Table 47).
In these modes, CS can temporarily return high on any byte
boundary, allowing time for the system controller to process the
next byte. CS can go high on byte boundaries only and can go
high during either part (instruction or data) of the transfer.
During this period, the serial control port state machine enters
a wait state until all data is sent. If the system controller decides
to abort the transfer before all of the data is sent, the state machine
must be reset, either by completing the remaining transfers or
by returning the CS low for at least one complete SCLK cycle
(but less than eight SCLK cycles). Raising the CS on a nonbyte
boundary terminates the serial transfer and flushes the buffer.
In the streaming mode (see Table 47), any number of data bytes
can be transferred in a continuous stream. The register address
is automatically incremented or decremented (see the MSB/LSB
First Transfers section). CS must be raised at the end of the last
byte to be transferred, thereby ending the stream mode.
Communication Cycle—Instruction Plus Data
There are two parts to a communication cycle with the AD9516.
The first part writes a 16-bit instruction word into the AD9516,
coincident with the first 16 SCLK rising edges. The instruction
word provides the AD9516 serial control port with information
regarding the data transfer, which is the second part of the
communication cycle. The instruction word defines whether
the upcoming data transfer is a read or a write, the number of
bytes in the data transfer, and the starting register address for
the first byte of the data transfer.
Write
If the instruction word is for a write operation, the second part
is the transfer of data into the serial control port buffer of the
AD9516. Data bits are registered on the rising edge of SCLK.
The length of the transfer (1, 2, 3 bytes or streaming mode) is
indicated by two bits ([W1:W0]) in the instruction byte. When
the transfer is 1, 2, or 3 bytes, but not streaming, CS can be
raised after each sequence of eight bits to stall the bus (except
after the last byte, where it ends the cycle). When the bus is
stalled, the serial transfer resumes when CS is lowered. Raising CS
on a nonbyte boundary resets the serial control port. During a
write, streaming mode does not skip over reserved or blank
registers; therefore, the user must know the bit pattern to write
to the reserved registers to preserve proper operation of the part.
Refer to the register map (see Table 52) to determine if the default
value for reserved registers is nonzero. It does not matter what data
is written to blank registers.
Because data is written into a serial control port buffer area, and
not directly into the actual control registers of the AD9516, an
additional operation is needed to transfer the serial control port
buffer contents to the actual control registers of the AD9516,
thereby causing them to become active. The update registers
operation consists of setting Register 0x232[0] = 1b (this bit is
self-clearing). Any number of bytes of data can be changed before
executing an update registers. The update registers operation
simultaneously actuates all register changes that have been
written to the buffer since any previous update.
Rev. C | Page 50 of 80
Data Sheet
AD9516-0
Read
If the instruction word is for a read operation, the next N × 8
SCLK cycles clock out the data from the address specified in the
instruction word, where N is 1 to 3 as determined by [W1:W0].
If N = 4, the read operation is in streaming mode, continuing
until CS is raised. Streaming mode does not skip over reserved
or blank registers. The readback data is valid on the falling
edge of SCLK.
The default mode of the AD9516 serial control port is the
bidirectional mode. In bidirectional mode, both the sent data
and the readback data appear on the SDIO pin. It is also possible
to set the AD9516 to unidirectional mode via the SDO active bit
(Register 0x000[0] = 1b). In unidirectional mode, the readback
data appears on the SDO pin.
A readback request reads the data that is in the serial control
port buffer area, or the data that is in the active registers (see
Figure 63). Readback of the buffer or active registers is controlled
by Register 0x004[0].
The AD9516 supports only the long instruction mode, therefore
Register 0x000[4:3] must be set to 11b. (This register uses mirrored
bits). Long instruction mode is the default at power-up or reset.
SERIAL
CONTROL
PORT
UPDATE
REGISTERS
WRITE REGISTER 0x232 = 0x01
TO UDATE REGISTERS
06419-037
CS
ACTIVE REGISTERS
SDO
BUFFER REGISTERS
SDIO
Figure 63. Relationship Between Serial Control Port Buffer Registers and
Active Registers of the AD9516
THE INSTRUCTION WORD (16 BITS)
The MSB of the instruction word is R/W, which indicates
whether the instruction is a read or a write. The next two bits,
[W1:W0], indicate the length of the transfer in bytes. The final
13 bits are the address ([A12:A0]) at which to begin the read or
write operation.
For a write, the instruction word is followed by the number of
bytes of data indicated by Bits[W1:W0] (see Table 47).
Table 47. Byte Transfer Count
W1
0
0
1
1
W0
0
1
0
1
Bytes to Transfer
1
2
3
Streaming mode
MSB/LSB FIRST TRANSFERS
The AD9516 instruction word and byte data can be MSB first
or LSB first. Any data written to Register 0x000 must be mirrored;
the upper four bits (Bits[7:4]) with the lower four bits (Bits[3:0]).
This makes it irrelevant whether LSB first or MSB first is in
effect. As an example of this mirroring, see the default setting
for this register: 0x18, which mirrors Bit 4 and Bit 3. This sets
the long instruction mode (which is the default and the only
mode that is supported).
The default for the AD9516 is MSB first.
When LSB first is set by Register 0x000[1] and Register 0x000[6],
it takes effect immediately because it affects only the operation
of the serial control port and does not require that an update
be executed.
When MSB first mode is active, the instruction and data bytes
must be written from MSB to LSB. Multibyte data transfers in
MSB first format start with an instruction byte that includes the
register address of the most significant data byte. Subsequent
data bytes must follow, in order, from the high address to the
low address. In MSB first mode, the serial control port internal
address generator decrements for each data byte of the
multibyte transfer cycle.
The AD9516 uses Register Address 0x000 to Register
Address 0x232.
SCLK
The 13 bits found in [A12:A0] select the address within the
register map that is written to or read from during the data
transfer portion of the communications cycle. Only Bits[A9:A0]
are needed to cover the range of the 0x232 registers used by the
AD9516. Bits[A12:A10] must always be 0b. For multibyte
transfers, this address is the starting byte address. In MSB first
mode, subsequent bytes decrement the address.
When LSB first is active, the instruction and data bytes must be
written from LSB to MSB. Multibyte data transfers in LSB first
format start with an instruction byte that includes the register
address of the least significant data byte followed by multiple
data bytes. The internal byte address generator of the serial
control port increments for each byte of the multibyte
transfer cycle.
The AD9516 serial control port register address decrements from
the register address just written toward 0x000 for multibyte I/O
operations if the MSB first mode is active (default). If the LSB
first mode is active, the register address of the serial control port
increments from the address just written toward Address 0x232
for multibyte I/O operations.
Streaming mode always terminates when it hits Address 0x232.
Note that unused addresses are not skipped during multibyte
I/O operations.
Table 48. Streaming Mode (No Addresses Are Skipped)
Write Mode
LSB first
MSB first
Rev. C | Page 51 of 80
Address Direction
Increment
Decrement
Stop Sequence
0x230, 0x231, 0x232, stop
0x001, 0x000, 0x232, stop
AD9516-0
Data Sheet
Table 49. Serial Control Port, 16-Bit Instruction Word, MSB First
MSB
I15
I14
I13
I12
I11
I10
I9
I8
I7
I6
I5
I4
I3
I2
I1
LSB
I0
R/W
W1
W0
A12 = 0
A11 = 0
A10 = 0
A9
A8
A7
A6
A5
A4
A3
A2
A1
A0
CS
SCLK DON'T CARE
SDIO DON'T CARE
R/W W1 W0 A12 A11 A10 A9
A8
A7
A6 A5
A4 A3 A2
A1 A0
D7 D6 D5
16-BIT INSTRUCTION HEADER
D4 D3
D2 D1
D0
D7
D6 D5
REGISTER (N) DATA
D4 D3 D2
D1 D0
DON'T CARE
REGISTER (N – 1) DATA
06419-038
DON'T CARE
Figure 64. Serial Control Port Write—MSB First, 16-Bit Instruction, Two Bytes Data
CS
SCLK
DON’T CARE
SDIO
DON’T CARE
R/W W1 W0 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0
SDO DON’T CARE
REGISTER (N) DATA
REGISTER (N – 1) DATA
REGISTER (N – 2) DATA
REGISTER (N – 3) DATA
DON’T
CARE
06419-039
D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0
16-BIT INSTRUCTION HEADER
Figure 65. Serial Control Port Read—MSB First, 16-Bit Instruction, Four Bytes Data
tDS
tHI
tS
tDH
CS
DON'T CARE
SDIO
DON'T CARE
DON'T CARE
R/W
W1
W0
A12
A11
A10
A9
A8
A7
A6
A5
D4
D3
D2
D1
D0
DON'T CARE
06419-040
SCLK
tC
tCLK
tLO
Figure 66. Serial Control Port Write—MSB First, 16-Bit Instruction, Timing Measurements
CS
SCLK
DATA BIT N
06419-041
tDV
SDIO
SDO
DATA BIT N – 1
Figure 67. Timing Diagram for Serial Control Port Register Read
CS
SCLK DON'T CARE
A4
A5 A6 A7
A8
A9 A10 A11 A12 W0 W1 R/W D0 D1 D2 D3 D4
16-BIT INSTRUCTION HEADER
D5 D6
REGISTER (N) DATA
D7
D0
D1 D2
D6
REGISTER (N + 1) DATA
Figure 68. Serial Control Port Write—LSB First, 16-Bit Instruction, Two Bytes Data
Rev. C | Page 52 of 80
D3 D4 D5
D7
DON'T CARE
06419-042
SDIO DON'T CARE
DON'T CARE
A0 A1 A2 A3
Data Sheet
AD9516-0
tS
tC
CS
tCLK
tHI
SCLK
tLO
tDS
SDIO
BI N
BI N + 1
Figure 69. Serial Control Port Timing—Write
Table 50. Serial Control Port Timing
Parameter
tDS
tDH
tCLK
tS
tC
tHIGH
tLOW
tDV
Description
Setup time between data and rising edge of SCLK
Hold time between data and rising edge of SCLK
Period of the clock
Setup time between CS falling edge and SCLK rising edge (start of communication cycle)
Setup time between SCLK rising edge and CS rising edge (end of communication cycle)
Minimum period that SCLK should be in a logic high state
Minimum period that SCLK should be in a logic low state
SCLK to valid SDIO and SDO (see Figure 67)
Rev. C | Page 53 of 80
06419-043
tDH
AD9516-0
Data Sheet
THERMAL PERFORMANCE
Table 51. Thermal Parameters for the 64-Lead LFCSP
Symbol
θJA
θJMA
θJMA
ΨJB
θJC
ΨJT
Thermal Characteristic Using a JEDEC JESD51-7 Plus JEDEC JESD51-5 2S2P Test Board
Junction-to-ambient thermal resistance, natural convection per JEDEC JESD51-2 (still air)
Junction-to-ambient thermal resistance, 1.0 m/sec airflow per JEDEC JESD51-6 (moving air)
Junction-to-ambient thermal resistance, 2.0 m/sec airflow per JEDEC JESD51-6 (moving air)
Junction-to-board characterization parameter, 1.0 m/sec airflow per JEDEC JESD51-6 (moving air)
and JEDEC JESD51-8
Junction-to-case thermal resistance (die-to-heat sink) per MIL-STD-883, Method 1012.1
Junction-to-top-of-package characterization parameter, natural convection per JEDEC JESD51-2 (still air)
The AD9516 is specified for a case temperature (TCASE). To ensure
that TCASE is not exceeded, an airflow source can be used.
Use the following equation to determine the junction
temperature on the application PCB:
Value (°C/W)
22.0
19.2
17.2
11.6
1.3
0.1
Values of θJA are provided for package comparison and PCB
design considerations. θJA can be used for a first-order
approximation of TJ by the following equation:
TJ = TA + (θJA × PD)
TJ = TCASE + (ΨJT × PD)
where TA is the ambient temperature (°C).
where:
TJ is the junction temperature (°C).
TCASE is the case temperature (°C) measured by the user at the
top center of the package.
ΨJT is the value from Table 51.
PD is the power dissipation of the device (see Table 17).
Values of θJC are provided for package comparison and PCB
design considerations when an external heat sink is required.
Values of ΨJB are provided for package comparison and PCB
design considerations.
Rev. C | Page 54 of 80
Data Sheet
AD9516-0
REGISTER MAP OVERVIEW
Table 52. Register Map Overview
Reg.
Addr.
(Hex)
Parameter
Bit 7 (MSB)
Serial Port Configuration
Serial port
SDO
0x000
configuration active
0x001
0x002
0x003
Part ID
Readback
0x004
control
PLL
0x010
0x011
0x012
0x013
0x014
0x015
0x016
PFD and
charge pump
R counter
A counter
B counter
PLL Control 1
0x017
0x018
PLL Control 2
PLL Control 3
0x019
PLL Control 4
0x01A
PLL Control 5
0x01B
PLL Control 6
0x01C
PLL Control 7
0x01D
PLL Control 8
0x01E
0x01F
PLL Control 9
PLL readback
0x020
to
0x04F
Bit 6
Bit 5
Bit 4
LSB first
Soft reset
Long
Long
instruction
instruction
Blank
Reserved
Part ID (read only)
Blank
PFD
polarity
Bit 3
Charge pump current
Bit 2
Bit 1
Bit 0 (LSB)
Default
Value
(Hex)
Soft reset
LSB first
SDO active
0x18
Charge pump mode
Read back
active
registers
PLL power-down
14-bit R divider, Bits[7:0] (LSB)
14-bit R divider, Bits[13:8] (MSB)
6-bit A counter
13-bit B counter, Bits[7:0] (LSB)
Blank
13-bit B counter, Bits[12:8] (MSB)
Set CP pin
Reset R
Reset A and
Reset all
B counter
Prescaler P
to VCP/2
counter
B counters
counters
bypass
STATUS pin control
Antibacklash pulse width
Disable
Digital lock
VCO calibration divider
VCO cal now
Reserved
Lock detect counter
digital lock
detect
detect
window
R path delay
N path delay
R, A, B counters SYNC
pin reset
Reference
LD pin control
Reserved
frequency
monitor
threshold
REF2
VCO
REF1 (REFIN)
REFMON pin control
frequency
frequency
(REFIN)
monitor
monitor
frequency
monitor
Disable
Select
Use
REF2
REF1
Differential
Reserved
Reserved
switchover REF2
REF_SEL pin
power-on
power-on
reference
deglitch
Holdover
Holdover
External
LD pin
PLL status
Reserved
enable
enable
holdover
comparator
register
control
enable
disable
Reserved
Digital
REF1
REF2
VCO cal
Holdover
REF2
VCO
Reserved
lock detect
frequency > frequency >
finished
active
selected
frequency >
threshold
threshold
threshold
Blank
Blank
Blank
Rev. C | Page 55 of 80
0x01
0x00
0x7D
0x01
0x00
0x00
0x03
0x00
0x06
0x00
0x06
0x00
0x00
0x00
0x00
0x00
0x00
N/A
AD9516-0
Data Sheet
Reg.
Addr.
(Hex)
Parameter
Bit 7 (MSB) Bit 6
Fine Delay Adjust—OUT6 to OUT9
0x0A0 OUT6 delay
bypass
0x0A1 OUT6 delay
Blank
full-scale
0x0A2 OUT6 delay
Blank
fraction
0x0A3 OUT7 delay
bypass
0x0A4 OUT7 delay
Blank
full-scale
0x0A5 OUT7 delay
Blank
fraction
0x0A6 OUT8 delay
bypass
0x0A7 OUT8 delay
Blank
full-scale
0x0A8 OUT8 delay
Blank
fraction
0x0A9 OUT9 delay
bypass
0x0AA OUT9 delay
Blank
full-scale
0x0AB OUT9 delay
Blank
fraction
0x0AC
to
0x0EF
LVPECL Outputs
0x0F0
OUT0
Blank
0x0F1
OUT1
Blank
0x0F2
OUT2
Blank
0x0F3
OUT3
Blank
0x0F4
OUT4
Blank
0x0F5
OUT5
Blank
0x0F6
to
0x13F
LVDS/CMOS Outputs
0x140
OUT6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0 (LSB)
OUT6 delay
bypass
OUT6 ramp current
Blank
OUT6 ramp capacitors
OUT6 delay fraction
OUT7 ramp capacitors
OUT7 delay fraction
OUT8 ramp capacitors
OUT8 delay fraction
OUT9 ramp capacitors
0x01
0x00
0x01
0x00
0x00
OUT9 delay
bypass
OUT9 ramp current
Blank
0x00
0x00
OUT8 delay
bypass
OUT8 ramp current
Blank
0x01
0x00
OUT7 delay
bypass
OUT7 ramp current
Blank
Default
Value
(Hex)
OUT9 delay fraction
0x01
0x00
0x00
Blank
OUT0
invert
OUT1
invert
OUT2
invert
OUT3
invert
OUT4
invert
OUT5
invert
OUT0 LVPECL
differential voltage
OUT1 LVPECL
differential voltage
OUT2 LVPECL
differential voltage
OUT3 LVPECL
differential voltage
OUT4 LVPECL
differential voltage
OUT5 LVPECL
differential voltage
OUT0 power-down
0x08
OUT1 power-down
0x0A
OUT2 power-down
0x08
OUT3 power-down
0x0A
OUT4 power-down
0x08
OUT5 power-down
0x0A
Blank
OUT6 CMOS
output polarity
0x141
OUT7
OUT7 CMOS
output polarity
0x142
OUT8
OUT8 CMOS
output polarity
0x143
OUT9
OUT9 CMOS
output polarity
OUT6 LVDS/
CMOS
output
polarity
OUT7 LVDS/
CMOS
output
polarity
OUT8 LVDS/
CMOS
output
polarity
OUT9 LVDS/
CMOS
output
polarity
OUT6
CMOS B
OUT6 select
LVDS/CMOS
OUT6 LVDS
output current
OUT6
power-down
0x42
OUT7
CMOS B
OUT7 select
LVDS/CMOS
OUT7 LVDS
output current
OUT7
power-down
0x43
OUT8
CMOS B
OUT8 select
LVDS/CMOS
OUT8 LVDS
output current
OUT8
power-down
0x42
OUT9
CMOS B
OUT9 select
LVDS/CMOS
OUT9 LVDS
output current
OUT9
power-down
0x43
Rev. C | Page 56 of 80
Data Sheet
AD9516-0
Reg.
Addr.
(Hex)
Parameter
Bit 7 (MSB)
0x144
to
0x18F
LVPECL Channel Dividers
Divider 0
0x190
(PECL)
Divider 0
0x191
bypass
0x192
Blank
0x193
Bit 4
Bit 3
Blank
Divider 0
no sync
Divider 0
force high
Divider 0
start high
Reserved
Divider 1 low cycles
Divider 1
bypass
0x195
Divider 1
no sync
Blank
Divider 2
(PECL)
Divider 1
force high
Divider 1
start high
Reserved
Divider 2 low cycles
Divider 2
bypass
0x197
Bit 5
Divider 0 low cycles
Divider 1
(PECL)
0x194
0x196
Bit 6
0x198
Divider 2
no sync
Blank
Divider 2
force high
Divider 2
start high
Reserved
Bit 2
Bit 1
Bit 0 (LSB)
Default
Value
(Hex)
Divider 0 high cycles
0x00
Divider 0 phase offset
0x80
Divider 0
direct to
output
Divider 1 high cycles
Divider 0
DCCOFF
0xBB
Divider 1 phase offset
Divider 1
direct to
output
Divider 2 high cycles
0x00
Divider 1
DCCOFF
0x00
0x00
Divider 2 phase offset
Divider 2
direct to
output
0x00
0x00
Divider 2
DCCOFF
0x00
LVDS/CMOS Channel Dividers
0x199
Divider 3
(LVDS/CMOS)
0x19A
0x19B
Low Cycles Divider 3.1
High Cycles Divider 3.1
0x22
Phase Offset Divider 3.2
Low Cycles Divider 3.2
Phase Offset Divider 3.1
High Cycles Divider 3.2
0x00
0x11
0x19C
Reserved
0x19D
Blank
0x19E
0x19F
0x1A0
0x1A1
Divider 4
(LVDS/CMOS)
Reserved
0x1A2
0x1A3
0x1A4
to
0x1DF
VCO Divider and CLK Input
0x1E0
VCO divider
0x1E1
Input CLKs
0x1E2
to
0x22A
Bypass
Divider 3.2
Bypass
Divider 3.1
Divider 3
no sync
Reserved
Divider 3
force high
Start High
Divider 3.2
Start High
Divider 3.1
Divider 3
DCCOFF
0x00
0x00
Low Cycles Divider 4.1
High Cycles Divider 4.1
0x22
Phase Offset Divider 4.2
Low Cycles Divider 4.2
Bypass
Divider 4.2
Phase Offset Divider 4.1
High Cycles Divider 4.2
Divider 4
Start High
force high
Divider 4.2
0x00
0x11
0x00
Blank
Bypass
Divider 4.1
Divider 4
no sync
Reserved
Start High
Divider 4.1
Divider 4
DCCOFF
0x00
Reserved
Blank
Blank
Reserved
Reserved
Power-down
PowerVCO clock
down
clock input interface
section
Blank
Rev. C | Page 57 of 80
Powerdown VCO
and CLK
VCO Divider
Select
Bypass VCO
VCO or CLK
divider
0x02
0x00
AD9516-0
Reg.
Addr.
(Hex)
Parameter
System
Power-down
0x230
and sync
0x231
Update All Registers
Update all
0x232
registers
Data Sheet
Bit 7 (MSB)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Powerdown sync
Powerdown
distribution
reference
Reserved
Reserved
Blank
Blank
Rev. C | Page 58 of 80
Bit 0 (LSB)
Default
Value
(Hex)
Soft sync
0x00
0x00
Update all
registers (selfclearing bit)
0x00
Data Sheet
AD9516-0
REGISTER MAP DESCRIPTIONS
Table 53 through Table 62 provide a detailed description of each of the control register functions. The registers are listed by hexadecimal
address. A range of bits (for example, from Bit 5 through Bit 2) is indicated using a colon and brackets, as follows: [5:2].
Table 53. Serial Port Configuration
Reg.
Addr
(Hex)
0x000
Bits
[7:4]
Name
Mirrored, Bits[3:0]
3
Long instruction
2
Soft reset
1
LSB first
0
SDO active
0x003
[7:0]
Part ID (read only)
0x004
0
Read back active registers
Description
Bits[7:4] should always mirror Bits[3:0] so that it does not matter whether the part is in MSB
or LSB first mode (see Bit 1, Register 0x000). The user should set the bits as follows:
Bit 7 = Bit 0.
Bit 6 = Bit 1.
Bit 5 = Bit 2.
Bit 4 = Bit 3.
Short/long instruction mode. This part uses long instruction mode only, so this bit should
always be set to 1.
0: 8-bit instruction (short).
1: 16-bit instruction (long) (default).
Soft reset.
1: soft reset; restores default values to internal registers. Not self-clearing. Must be cleared to
0 to complete reset operation.
MSB or LSB data orientation.
0: data-oriented MSB first; addressing decrements (default).
1: data-oriented LSB first; addressing increments.
Selects unidirectional or bidirectional data transfer mode.
0: SDIO pin used for write and read; SDO set to high impedance; bidirectional mode (default).
1: SDO used for read, SDIO used for write; unidirectional mode.
Uniquely identifies the dash version (-0 through -4) of the AD9516.
AD9516-0: 0x01.
AD9516-1: 0x41.
AD9516-2: 0x81.
AD9516-3: 0x43.
AD9516-4: 0xC3.
Selects register bank used for a readback.
0: reads back buffer registers (default).
1: reads back active registers.
Rev. C | Page 59 of 80
AD9516-0
Data Sheet
Table 54. PLL
Reg.
Addr.
(Hex)
0x010
Bits
7
Name
PFD polarity
[6:4]
CP current
[3:2]
CP mode
[1:0]
PLL power-down
0x011
[7:0]
0x012
[5:0]
0x013
0x014
[5:0]
[7:0]
0x015
[4:0]
0x016
7
14-bit R divider,
Bits[7:0] (LSB)
14-bit R divider,
Bits[13:8] (MSB)
6-bit A counter
13-bit B counter,
Bits[7:0] (LSB)
13-bit B counter,
Bits[12:8] (MSB)
Set CP pin to VCP/2
6
Reset R counter
5
Reset A, B counters
4
Reset all counters
3
B counter
bypass
Description
Sets the PFD polarity. Negative polarity is for use (if needed) with external VCO/VCXO only. The on-chip VCO requires
positive polarity; Bit 7 = 0.
0: positive; higher control voltage produces higher frequency (default).
1: negative; higher control voltage produces lower frequency.
Charge pump current (with CPRSET = 5.1 kΩ).
6
5
4
ICP (mA)
0
0
0
0.6
0
0
1
1.2
0
1
0
1.8
0
1
1
2.4
1
0
0
3.0
1
0
1
3.6
1
1
0
4.2
1
1
1
4.8 (default)
Charge pump operating mode.
3
2
Charge Pump Mode
0
0
High impedance state.
0
1
Force source current (pump up).
1
0
Force sink current (pump down).
1
1
Normal operation (default).
PLL operating mode.
1
0
Mode
0
0
Normal operation.
0
1
Asynchronous power-down (default).
1
0
Normal operation.
1
1
Synchronous power-down.
R divider LSBs—lower eight bits (default = 0x01).
R divider MSBs—upper six bits (default = 0x00).
A counter (part of N divider) (default = 0x00).
B counter (part of N divider)—lower eight bits (default = 0x03).
B counter (part of N divider)—upper five bits (default = 0x00).
Sets the CP pin to one-half of the VCP supply voltage.
0: CP normal operation (default).
1: CP pin set to VCP/2.
Resets R counter (R divider).
0: normal (default).
1: holds the R counter in reset.
Resets A and B counters (part of N divider).
0: normal (default).
1: holds the A and B counters in reset.
Resets R, A, and B counters.
0: normal (default).
1: holds the R, A, and B counters in reset.
B counter bypass. This is valid only when operating the prescaler in FD mode.
0: normal (default).
1: B counter is set to divide-by-1. This allows the prescaler setting to determine the divide for the N divider.
Rev. C | Page 60 of 80
Data Sheet
Reg.
Addr.
(Hex)
0x016
0x017
Bits
[2:0]
[7:2]
Name
Prescaler P
STATUS pin
control
AD9516-0
Description
Prescaler: DM = dual modulus, and FD = fixed divide.
2
1
0
Mode
Prescaler
0
0
0
FD
Divide-by-1.
0
0
1
FD
Divide-by-2.
0
1
0
DM
Divide-by-2 (2/3 mode).
0
1
1
DM
Divide-by-4 (4/5 mode).
1
0
0
DM
Divide-by-8 (8/9 mode).
1
0
1
DM
Divide-by-16 (16/17 mode).
1
1
0
DM
Divide-by-32 (32/33 mode) (default).
1
1
1
FD
Divide-by-3.
Selects the signal that is connected to the STATUS pin.
Level or
Dynamic
Signal
Signal at STATUS Pin
7
6
5
4
3
2
0
0
0
0
0
0
LVL
Ground (dc) (default).
0
0
0
0
0
1
DYN
N divider output (after the delay).
0
0
0
0
1
0
DYN
R divider output (after the delay).
0
0
0
0
1
1
DYN
A divider output.
0
0
0
1
0
0
DYN
Prescaler output.
0
0
0
1
0
1
DYN
PFD up pulse.
0
0
0
1
1
0
DYN
PFD down pulse.
0
X
X
X
X
X
LVL
Ground (dc); for all other cases of 0XXXXX not specified above.
The selections that follow are the same as REFMON.
1
0
0
0
0
0
LVL
Ground (dc).
1
0
0
0
0
1
DYN
REF1 clock (differential reference when in differential mode).
1
0
0
0
1
0
DYN
REF2 clock (not available in differential mode).
1
0
0
0
1
1
DYN
Selected reference to PLL (differential reference when in differential mode).
1
0
0
1
0
0
DYN
Unselected reference to PLL (not available in differential mode).
Status of selected reference (status of differential reference); active
1
0
0
1
0
1
LVL
high.
Status of unselected reference (not available in differential mode);
1
0
0
1
1
0
LVL
active high.
1
0
0
1
1
1
LVL
Status REF1 frequency (active high).
1
0
1
0
0
0
LVL
Status REF2 frequency (active high).
1
0
1
0
0
1
LVL
(Status REF1 frequency) AND (status REF2 frequency).
1
0
1
0
1
0
LVL
(DLD) AND (status of selected reference) AND (status of VCO).
1
0
1
0
1
1
LVL
Status of VCO frequency (active high).
1
0
1
1
0
0
LVL
Selected reference (low = REF1, high = REF2).
1
0
1
1
0
1
LVL
Digital lock detect (DLD); active high.
1
0
1
1
1
0
LVL
Holdover active (active high).
1
0
1
1
1
1
LVL
LD pin comparator output (active high).
1
1
0
0
0
0
LVL
VS (PLL supply).
1
1
0
0
0
1
DYN
REF1 clock (differential reference when in differential mode).
1
1
0
0
1
0
DYN
REF2 clock (not available in differential mode).
1
1
0
0
1
1
DYN
Selected reference to PLL (differential reference when in differential mode).
1
1
0
1
0
0
DYN
Unselected reference to PLL (not available when in differential mode).
1
1
0
1
0
1
LVL
Status of selected reference (status of differential reference); active low.
1
1
0
1
1
0
LVL
Status of unselected reference (not available in differential mode); active low.
1
1
0
1
1
1
LVL
Status of REF1 frequency (active low).
1
1
1
0
0
0
LVL
Status of REF2 frequency (active low).
1
1
1
0
0
1
LVL
(Status of REF1 frequency) AND (status of REF2 frequency).
1
1
1
0
1
0
LVL
(DLD) AND (status of selected reference) AND (status of VCO).
1
1
1
0
1
1
LVL
Status of VCO frequency (active low).
1
1
1
1
0
0
LVL
Selected reference (low = REF2, high = REF1).
1
1
1
1
0
1
LVL
Digital lock detect (DLD) (active low).
1
1
1
1
1
0
LVL
Holdover active (active low).
1
1
1
1
1
1
LVL
LD pin comparator output (active low).
Rev. C | Page 61 of 80
AD9516-0
Data Sheet
Reg.
Addr.
(Hex)
0x017
Bits
[1:0]
Name
Antibacklash
pulse width
0x018
[6:5]
Lock detect
counter
4
Digital lock detect
window
3
Disable digital
lock detect
[2:1]
VCO cal
divider
[0]
VCO cal now
0x019
[7:6]
R, A, B counters
SYNC pin reset
0x01A
[5:3]
[2:0]
[6]
R path delay
N path delay
Reference
frequency monitor
threshold
Description
1
0
Antibacklash Pulse Width (ns)
0
0
2.9 (default).
0
1
1.3.
1
0
6.0.
1
1
2.9.
Required consecutive number of PFD cycles with edges inside lock detect window before the DLD indicates a locked
condition.
6
5
PFD Cycles to Determine Lock
0
0
5 (default).
0
1
16.
1
0
64.
1
1
255.
If the time difference of the rising edges at the inputs to the PFD is less than the lock detect window time, the digital lock
detect flag is set. The flag remains set until the time difference is greater than the loss-of-lock threshold.
0: high range (default).
1: low range.
Digital lock detect operation.
0: normal lock detect operation (default).
1: disables lock detect.
VCO calibration divider. Divider used to generate the VCO calibration clock from the PLL reference clock.
2
1
VCO Calibration Clock Divider
0
0
2.
0
1
4.
1
0
8.
1
1
16 (default).
Bit used to initiate the VCO calibration. This bit must be toggled from 0 to 1 in the active registers. To initiate
calibration, use the following three steps: first, ensure that the input reference signal is present; second, set to 0 (if not
zero already), followed by an update bit (Register 0x232, Bit 0); and third, program to 1, followed by another update bit
(Register 0x232, Bit 0).
7
6
Action
0
0
Does nothing on SYNC (default).
0
1
Asynchronous reset.
1
0
Synchronous reset.
1
1
Does nothing on SYNC.
R path delay (default = 0x00) (see Table 2).
N path delay (default = 0x00) (see Table 2).
Sets the reference (REF1/REF2) frequency monitor’s detection threshold frequency. This does not affect the VCO
frequency monitor’s detection threshold (see Table 16: REF1, REF2, and VCO Frequency Status Monitor parameter).
0: frequency valid if frequency is above the higher frequency threshold (default).
1: frequency valid if frequency is above the lower frequency threshold.
Rev. C | Page 62 of 80
Data Sheet
Reg.
Addr.
(Hex)
0x01A
Bits
[5:0]
Name
LD pin control
0x01B
7
VCO frequency
monitor
6
REF2 (REFIN)
frequency monitor
5
REF1 (REFIN)
frequency monitor
AD9516-0
Description
Selects the signal that is connected to the LD pin.
Level or
Dynamic
Signal
Signal at LD Pin
5
4
3
2
1
0
0
0
0
0
0
0
LVL
Digital lock detect (high = lock, low = unlock) (default).
0
0
0
0
0
1
DYN
P-channel, open-drain lock detect (analog lock detect).
0
0
0
0
1
0
DYN
N-channel, open-drain lock detect (analog lock detect).
0
0
0
0
1
1
HIZ
High-Z LD pin.
0
0
0
1
0
0
CUR
Current source lock detect (110 µA when DLD is true).
0
X
X
X
X
X
LVL
Ground (dc); for all other cases of 0XXXXX not specified above.
The selections that follow are the same as REFMON.
1
0
0
0
0
0
LVL
Ground (dc).
1
0
0
0
0
1
DYN
REF1 clock (differential reference when in differential mode).
1
0
0
0
1
0
DYN
REF2 clock (not available in differential mode).
1
0
0
0
1
1
DYN
Selected reference to PLL (differential reference when indifferential mode).
1
0
0
1
0
0
DYN
Unselected reference to PLL (not available in differential mode).
1
0
0
1
0
1
LVL
Status of selected reference (status of differential reference); active high.
Status of unselected reference (not available in differential mode); active
1
0
0
1
1
0
LVL
high.
1
0
0
1
1
1
LVL
Status REF1 frequency (active high).
1
0
1
0
0
0
LVL
Status REF2 frequency (active high).
1
0
1
0
0
1
LVL
(Status REF1 frequency) AND (status REF2 frequency).
1
0
1
0
1
0
LVL
(DLD) AND (status of selected reference) AND (status of VCO).
1
0
1
0
1
1
LVL
Status of VCO frequency (active high).
1
0
1
1
0
0
LVL
Selected reference (low = REF1, high = REF2).
1
0
1
1
0
1
LVL
Digital lock detect (DLD); active high.
1
0
1
1
1
0
LVL
Holdover active (active high).
1
0
1
1
1
1
LVL
Not available. Do not use.
1
1
0
0
0
0
LVL
VS (PLL supply).
1
1
0
0
0
1
DYN
REF1 clock (differential reference when in differential mode).
1
1
0
0
1
0
DYN
REF2 clock (not available in differential mode).
1
1
0
0
1
1
DYN
Selected reference to PLL (differential reference when in differential mode).
1
1
0
1
0
0
DYN
Unselected reference to PLL (not available when in differential mode).
1
1
0
1
0
1
LVL
Status of selected reference (status of differential reference); active low.
Status of unselected reference (not available in differential mode); active
1
1
0
1
1
0
LVL
low.
1
1
0
1
1
1
LVL
Status of REF1 frequency (active low).
1
1
1
0
0
0
LVL
Status of REF2 frequency (active low).
1
1
1
0
0
1
LVL
(Status of REF1 frequency) AND (status of REF2 frequency).
1
1
1
0
1
0
LVL
(DLD) AND (status of selected reference) AND (status of VCO).
1
1
1
0
1
1
LVL
Status of VCO frequency (active low).
1
1
1
1
0
0
LVL
Selected reference (low = REF2, high = REF1).
1
1
1
1
0
1
LVL
Digital lock detect (DLD); active low.
1
1
1
1
1
0
LVL
Holdover active (active low).
1
1
1
1
1
1
LVL
Not available. Do not use.
Enables or disables VCO frequency monitor.
0: disables VCO frequency monitor (default).
1: enables VCO frequency monitor.
Enables or disables REF2 frequency monitor.
0: disables REF2 frequency monitor (default).
1: enables REF2 frequency monitor.
REF1 (REFIN) frequency monitor enable; this is for both REF1 (single-ended) and REFIN (differential) inputs
(as selected by differential reference mode).
0: disables REF1 (REFIN) frequency monitor (default).
1: enables REF1 (REFIN) frequency monitor.
Rev. C | Page 63 of 80
AD9516-0
Data Sheet
Reg.
Addr.
(Hex)
0x01B
Bits
[4:0]
Name
REFMON
pin control
0x01C
7
6
Disable
switchover
deglitch
Select REF2
5
Use REF_SEL pin
4
3
2
Reserved
Reserved
REF2 power-on
1
REF1 power-on
0
Differential
reference
Description
Selects the signal that is connected to the REFMON pin.
Level or
Dynamic
Signal
Signal at REFMON Pin
4
3
2
1
0
0
0
0
0
0
LVL
Ground (dc) (default).
0
0
0
0
1
DYN
REF1 clock (differential reference when in differential mode).
0
0
0
1
0
DYN
REF2 clock (not available in differential mode).
0
0
0
1
1
DYN
Selected reference to PLL (differential reference when in differential mode).
0
0
1
0
0
DYN
Unselected reference to PLL (not available in differential mode).
0
0
1
0
1
LVL
Status of selected reference (status of differential reference); active high.
0
0
1
1
0
LVL
Status of unselected reference (not available in differential mode); active high.
0
0
1
1
1
LVL
Status REF1 frequency (active high).
0
1
0
0
0
LVL
Status REF2 frequency (active high).
0
1
0
0
1
LVL
(Status REF1 frequency) AND (status REF2 frequency).
0
1
0
1
0
LVL
(DLD) AND (status of selected reference) AND (status of VCO).
0
1
0
1
1
LVL
Status of VCO frequency (active high).
0
1
1
0
0
LVL
Selected reference (low = REF1, high = REF2).
0
1
1
0
1
LVL
Digital lock detect (DLD); active low.
0
1
1
1
0
LVL
Holdover active (active high).
0
1
1
1
1
LVL
LD pin comparator output (active high).
1
0
0
0
0
LVL
VS (PLL supply).
1
0
0
0
1
DYN
REF1 clock (differential reference when in differential mode).
1
0
0
1
0
DYN
REF2 clock (not available in differential mode).
1
0
0
1
1
DYN
Selected reference to PLL (differential reference when in differential mode).
1
0
1
0
0
DYN
Unselected reference to PLL (not available when in differential mode).
1
0
1
0
1
LVL
Status of selected reference (status of differential reference); active low.
1
0
1
1
0
LVL
Status of unselected reference (not available in differential mode); active low.
1
0
1
1
1
LVL
Status of REF1 frequency (active low).
1
1
0
0
0
LVL
Status of REF2 frequency (active low).
1
1
0
0
1
LVL
(Status of REF1 frequency) AND (Status of REF2 frequency).
1
1
0
1
0
LVL
(DLD) AND (Status of selected reference) AND (Status of VCO).
1
1
0
1
1
LVL
Status of VCO frequency (active low).
1
1
1
0
0
LVL
Selected reference (low = REF2, high = REF1).
1
1
1
0
1
LVL
Digital lock detect (DLD); active low.
1
1
1
1
0
LVL
Holdover active (active low).
1
1
1
1
1
LVL
LD pin comparator output (active low).
Disables or enables the switchover deglitch circuit.
0: enables switchover deglitch circuit (default).
1: disables switchover deglitch circuit.
If Register 0x01C, Bit 5 = 0, select reference for PLL.
0: selects REF1 (default).
1: selects REF2.
Sets method of PLL reference selection.
0: uses Register 0x01C, Bit 6 (default).
1: uses REF_SEL pin.
0: (default).
0: (default).
This bit turns the REF2 power on.
0: REF2 power off (default).
1: REF2 power on.
This bit turns the REF1 power on.
0: REF1 power off (default).
1: REF1 power on.
Selects the PLL reference mode, differential or single-ended. Single-ended must be selected for the automatic
switchover or REF1 and REF2 to work.
0: single-ended reference mode (default).
1: differential reference mode.
Rev. C | Page 64 of 80
Data Sheet
Reg.
Addr.
(Hex)
0x01D
0x01F
Bits
4
Name
PLL status
register disable
3
LD pin comparator
enable
2
Holdover enable
1
External
holdover control
0
Holdover enable
6
VCO cal finished
5
Holdover active
4
REF2 selected
3
VCO frequency >
threshold
2
REF2 frequency >
threshold
1
REF1 frequency >
threshold
0
Digital lock detect
AD9516-0
Description
Disables the PLL status register readback.
0: PLL status register enable (default).
1: PLL status register disable.
Enables the LD pin voltage comparator. This function is used with the LD pin current source lock detect mode. When
in the internal (automatic) holdover mode, this function enables the use of the voltage on the LD pin to determine if
the PLL was previously in a locked state (see Figure 53). Otherwise, this function can be used with the REFMON and
STATUS pins to monitor the voltage on this pin.
0: disables LD pin comparator; internal/automatic holdover controller treats this pin as true (high) (default).
1: enables LD pin comparator.
Along with Bit 0, enables the holdover function. Automatic holdover must be disabled during VCO calibration.
0: holdover disabled (default).
1: holdover enabled.
Enables the external hold control through the SYNC pin. (This disables the internal holdover mode.)
0: automatic holdover mode—holdover controlled by automatic holdover circuit. (default)
1: external holdover mode—holdover controlled by SYNC pin.
Along with Bit 2, enables the holdover function. Automatic holdover must be disabled during VCO calibration.
0: holdover disabled (default).
1: holdover enabled.
Read-only register. Indicates status of the VCO calibration.
0: VCO calibration not finished.
1: VCO calibration finished.
Read-only register. Indicates if the part is in the holdover state (see Figure 53). This is not the same as holdover enabled.
0: not in holdover.
1: holdover state active.
Read-only register. Indicates which PLL reference is selected as the input to the PLL.
0: REF1 selected (or differential reference if in differential mode).
1: REF2 selected.
Read-only register. Indicates if the VCO frequency is greater than the threshold (see Table 16: REF1, REF2, and VCO
frequency status monitor).
0: VCO frequency is less than the threshold.
1: VCO frequency is greater than the threshold.
Read-only register. Indicates if the frequency of the signal at REF2 is greater than the threshold frequency set by
Register 0x01A, Bit 6.
0: REF2 frequency is less than threshold frequency.
1: REF2 frequency is greater than threshold frequency.
Read-only register. Indicates if the frequency of the signal at REF2 is greater than the threshold frequency
set by Register 0x01A, Bit 6.
0: REF1 frequency is less than threshold frequency.
1: REF1 frequency is greater than threshold frequency.
Read-only register. Digital lock detect.
0: PLL is not locked.
1: PLL is locked.
Rev. C | Page 65 of 80
AD9516-0
Data Sheet
Table 55. Fine Delay Adjust—OUT6 to OUT9
Reg.
Addr.
(Hex)
0x0A0
Bits
0
Name
OUT6 delay bypass
0x0A1
[5:3]
OUT6 ramp capacitors
[2:0]
OUT6 ramp current
0x0A2
[5:0]
OUT6 delay fraction
0x0A3
0
OUT7 delay bypass
0x0A4
[5:3]
OUT7 ramp capacitors
Description
Bypasses or uses the delay function.
0: uses delay function.
1: bypasses delay function (default).
Selects the number of ramp capacitors used by the delay function. The combination of the
number of the capacitors and the ramp current sets the delay full scale.
5
4 3 Number of Capacitors
0
0 0 4 (default)
0
0 1 3
0
1 0 3
0
1 1 2
1
0 0 3
1
0 1 2
1
1 0 2
1
1 1 1
Ramp current for the delay function. The combination of the number of capacitors and the ramp
current sets the delay full scale.
2
1 0 Current (µA)
0
0 0 200 (default)
0
0 1 400
0
1 0 600
0
1 1 800
1
0 0 1000
1
0 1 1200
1
1 0 1400
1
1 1 1600
Selects the fraction of the full-scale delay desired (6-bit binary).
A setting of 000000 gives zero delay.
Only delay values up to 47 decimals (101111b; 0x2F) are supported (default = 0x00).
Bypasses or uses the delay function.
0: use delay function.
1: bypass delay function (default).
Selects the number of ramp capacitors used by the delay function. The combination of the
number of the capacitors and the ramp current sets the delay full scale.
5
4 3 Number of Capacitors
0
0 0 4 (default)
0
0 1 3
0
1 0 3
0
1 1 2
1
0 0 3
1
0 1 2
1
1 0 2
1
1 1 1
Rev. C | Page 66 of 80
Data Sheet
Reg.
Addr.
(Hex)
0x0A4
Bits
[2:0]
Name
OUT7 ramp current
0x0A5
[5:0]
OUT7 delay fraction
0x0A6
0
OUT8 delay bypass
0x0A7
[5:3]
OUT8 ramp capacitors
[2:0]
OUT8 ramp current
[5:0]
OUT8 delay fraction
0x0A8
AD9516-0
Description
Ramp current for the delay function. The combination of the number of capacitors and the ramp
current sets the delay full scale.
2
1
0
Current (µA)
0
0
0
200 (default)
0
0
1
400
0
1
0
600
0
1
1
800
1
0
0
1000
1
0
1
1200
1
1
0
1400
1
1
1
1600
Selects the fraction of the full-scale delay desired (6-bit binary).
A setting of 000000 gives zero delay.
Only delay values up to 47 decimals (101111b; 0x2F) are supported (default = 0x00).
Bypasses or uses the delay function.
0: uses delay function.
1: bypasses delay function (default).
Selects the number of ramp capacitors used by the delay function. The combination of the
number of capacitors and the ramp current sets the delay full scale.
5
4
3
Number of Capacitors
0
0
0
4 (default)
0
0
1
3
0
1
0
3
0
1
1
2
1
0
0
3
1
0
1
2
1
1
0
2
1
1
1
1
Ramp current for the delay function. The combination of the number of capacitors and the ramp
current sets the delay full scale.
2
1
0
Current (µA)
0
0
0
200 (default)
0
0
1
400
0
1
0
600
0
1
1
800
1
0
0
1000
1
0
1
1200
1
1
0
1400
1
1
1
1600
Selects the fraction of the full-scale delay desired (6-bit binary).
A setting of 000000 gives zero delay.
Only delay values up to 47 decimals (101111b; 0x2F) are supported (default = 0x00).
Rev. C | Page 67 of 80
AD9516-0
Data Sheet
Reg.
Addr.
(Hex)
0x0A9
Bits
0
Name
OUT9 delay bypass
0x0AA
[5:3]
OUT9 ramp capacitors
[2:0]
OUT9 ramp current
[5:0]
OUT9 delay fraction
0x0AB
Description
Bypasses or uses the delay function.
0: uses delay function.
1: bypasses delay function (default).
Selects the number of ramp capacitors used by the delay function. The combination of the
number of capacitors and the ramp current sets the delay full scale.
5
4
3
Number of Capacitors
0
0
0
4 (default)
0
0
1
3
0
1
0
3
0
1
1
2
1
0
0
3
1
0
1
2
1
1
0
2
1
1
1
1
Ramp current for the delay function. The combination of the number of capacitors and the ramp
current sets the delay full scale.
2
1
0
Current Value (µA)
0
0
0
200 (default)
0
0
1
400
0
1
0
600
0
1
1
800
1
0
0
1000
1
0
1
1200
1
1
0
1400
1
1
1
1600
Selects the fraction of the full-scale delay desired (6-bit binary).
A setting of 000000 gives zero delay.
Only delay values up to 47 decimals (101111b; 0x2F) are supported (default = 0x00).
Table 56. LVPECL Outputs
Reg.
Addr.
(Hex)
0x0F0
Bits
4
Name
OUT0 invert
[3:2]
OUT0 LVPECL
differential voltage
[1:0]
OUT0 power-down
Description
Sets the output polarity.
0: noninverting (default).
1: inverting.
Sets the LVPECL output differential voltage (VOD).
3
2
VOD (mV)
0
0
400
0
1
600
1
0
780 (default)
1
1
960
LVPECL power-down modes.
1
0
Mode
0
0
Normal operation (default).
0
1
Partial power-down, reference on; use only if there are no external
load resistors.
1
0
Partial power-down, reference on, safe LVPECL power-down.
1
1
Total power-down, reference off; use only if there are no external
load resistors.
Rev. C | Page 68 of 80
Output
On
Off
Off
Off
Data Sheet
Reg.
Addr.
(Hex)
0x0F1
0x0F2
0x0F3
Bits
4
Name
OUT1 invert
[3:2]
OUT1 LVPECL
differential voltage
[1:0]
OUT1 power-down
4
OUT2 invert
[3:2]
OUT2 LVPECL
differential voltage
[1:0]
OUT2 power-down
4
OUT3 invert
[3:2]
OUT3 LVPECL
differential voltage
[1:0]
OUT3 power-down
AD9516-0
Description
Sets the output polarity.
0: noninverting (default).
1: inverting.
Sets the LVPECL output differential voltage (VOD).
3
2
VOD (mV)
0
0
400
0
1
600
1
0
780 (default)
1
1
960
LVPECL power-down modes.
1
0
Mode
0
0
Normal operation.
0
1
Partial power-down, reference on; use only if there are no external load
resistors.
1
0
Partial power-down, reference on, safe LVPECL power-down (default).
1
1
Total power-down, reference off; use only if there are no external load
resistors.
Sets the output polarity.
0: noninverting (default).
1: inverting.
Sets the LVPECL output differential voltage (VOD).
3
2
VOD (mV)
0
0
400
0
1
600
1
0
780 (default)
1
1
960
LVPECL power-down modes.
1
0
Mode
0
0
Normal operation (default).
0
1
Partial power-down, reference on; use only if there are no external load
resistors.
1
0
Partial power-down, reference on, safe LVPECL power-down.
1
1
Total power-down, reference off; use only if there are no external load
resistors.
Sets the output polarity.
0: noninverting (default).
1: inverting.
Sets the LVPECL output differential voltage (VOD).
3
2
VOD (mV)
0
0
400
0
1
600
1
0
780 (default)
1
1
960
LVPECL power-down modes.
1
0
Mode
0
0
Normal operation.
0
1
Partial power-down, reference on; use only if there are no external
load resistors.
1
0
Partial power-down, reference on, safe LVPECL power-down (default).
1
1
Total power-down, reference off; use only if there are no external
load resistors.
Rev. C | Page 69 of 80
Output
On
Off
Off
Off
Output
On
Off
Off
Off
Output
On
Off
Off
Off
AD9516-0
Reg.
Addr.
(Hex)
0x0F4
0x0F5
Data Sheet
Bits
4
Name
OUT4 invert
[3:2]
OUT4 LVPECL
differential voltage
[1:0]
OUT4 power-down
4
OUT5 invert
[3:2]
OUT5 LVPECL
differential voltage
[1:0]
OUT5 power-down
Description
Sets the output polarity.
0: noninverting (default).
1: inverting.
Sets the LVPECL output differential voltage (VOD).
3
2
VOD (mV)
0
0
400
0
1
600
1
0
780 (default)
1
1
960
LVPECL power-down modes.
1
0
Mode
0
0
Normal operation (default).
0
1
Partial power-down, reference on; use only if there are no external load
resistors.
1
0
Partial power-down, reference on, safe LVPECL power-down.
1
1
Total power-down, reference off; use only if there are no external load
resistors.
Sets the output polarity.
0: noninverting (default).
1: inverting.
Sets the LVPECL output differential voltage (VOD).
3
2
VOD (mV)
0
0
400
0
1
600
1
0
780 (default)
1
1
960
LVPECL power-down modes.
1
0
Mode
0
0
Normal operation.
0
1
Partial power-down, reference on; use only if there are no external load
resistors.
1
0
Partial power-down, reference on, safe LVPECL power-down (default).
1
1
Total power-down, reference off; use only if there are no external load
resistors.
Rev. C | Page 70 of 80
Output
On
Off
Off
Off
Output
On
Off
Off
Off
Data Sheet
AD9516-0
Table 57. LVDS/CMOS Outputs
Reg.
Addr.
(Hex)
0x140
0x141
Bits
[7:5]
Name
OUT6 output polarity
4
OUT6 CMOS B
3
OUT6 select LVDS/CMOS
[2:1]
OUT6 LVDS output current
0
OUT6 power-down
[7:5]
OUT7 output polarity
4
OUT7 CMOS B
3
OUT7 select LVDS/CMOS
[2:1]
OUT7 LVDS output current
Description
In CMOS mode, Bits[7:5] select the output polarity of each CMOS output.
In LVDS mode, only Bit 5 determines LVDS polarity.
7
6
5
OUT4A (CMOS)
OUT4B (CMOS)
OUT4 (LVDS)
0
0
0
Noninverting
Inverting
Noninverting
0
1
0
Noninverting
Noninverting
Noninverting (default)
1
0
0
Inverting
Inverting
Noninverting
1
1
0
Inverting
Noninverting
Noninverting
0
0
1
Inverting
Noninverting
Inverting
0
1
1
Inverting
Inverting
Inverting
1
0
1
Noninverting
Noninverting
Inverting
1
1
1
Noninverting
Inverting
Inverting
In CMOS mode, turns on/off the CMOS B output. There is no effect in LVDS mode.
0: turns off the CMOS B output (default).
1: turns on the CMOS B output.
Selects LVDS or CMOS logic levels.
0: LVDS (default).
1: CMOS.
Set output current level in LVDS mode. This has no effect in CMOS mode.
2
1
Current (mA)
Recommended Termination (Ω)
0
0
1.75
100
0
1
3.5
100 (default)
1
0
5.25
50
1
1
7
50
Power-down output (LVDS/CMOS).
0: power on (default).
1: power off.
In CMOS mode, Bits[7:5] select the output polarity of each CMOS output.
In LVDS mode, only Bit 5 determines LVDS polarity.
7
6
5
OUT5A (CMOS)
OUT5B (CMOS)
OUT5 (LVDS)
0
0
0
Noninverting
Inverting
Noninverting
0
1
0
Noninverting
Noninverting
Noninverting (default)
1
0
0
Inverting
Inverting
Noninverting
1
1
0
Inverting
Noninverting
Noninverting
0
0
1
Inverting
Noninverting
Inverting
0
1
1
Inverting
Inverting
Inverting
1
0
1
Noninverting
Noninverting
Inverting
1
1
1
Noninverting
Inverting
Inverting
In CMOS mode, turns on/off the CMOS B output. There is no effect in LVDS mode.
0: turns off the CMOS B output (default).
1: turns on the CMOS B output.
Select LVDS or CMOS logic levels.
0: LVDS (default).
1: CMOS.
Sets output current level in LVDS mode. This has no effect in CMOS mode.
2
1
Current (mA)
Recommended Termination (Ω)
0
0
1.75
100
0
1
3.5
100 (default)
1
0
5.25
50
1
1
7
50
Rev. C | Page 71 of 80
AD9516-0
Data Sheet
Reg.
Addr.
(Hex)
0x141
Bits
0
Name
OUT7 power-down
0x142
[7:5]
OUT8 output polarity
4
OUT8 CMOS B
3
OUT8 select LVDS/CMOS
[2:1]
OUT8 LVDS output current
0
OUT8 power-down
[7:5]
OUT9 output polarity
4
OUT9 CMOS B
3
OUT9 select LVDS/CMOS
0x143
Description
Power-down output (LVDS/CMOS).
0: power on.
1: power off (default).
In CMOS mode, Bits[7:5] select the output polarity of each CMOS output.
In LVDS mode, only Bit 5 determines LVDS polarity.
7
6
5
OUT6A (CMOS)
OUT6B (CMOS)
OUT6 (LVDS)
0
0
0
Noninverting
Inverting
Noninverting
0
1
0
Noninverting
Noninverting
Noninverting (default)
1
0
0
Inverting
Inverting
Noninverting
1
1
0
Inverting
Noninverting
Noninverting
0
0
1
Inverting
Noninverting
Inverting
0
1
1
Inverting
Inverting
Inverting
1
0
1
Noninverting
Noninverting
Inverting
1
1
1
Noninverting
Inverting
Inverting
In CMOS mode, turns on/off the CMOS B output. There is no effect in LVDS mode.
0: turn off the CMOS B output (default).
1: turn on the CMOS B output.
Selects LVDS or CMOS logic levels.
0: LVDS (default).
1: CMOS.
Sets output current level in LVDS mode. This has no effect in CMOS mode.
2
1
Current (mA)
Recommended Termination (Ω)
0
0
1.75
100
0
1
3.5
100 (default)
1
0
5.25
50
1
1
7
50
Power-down output (LVDS/CMOS).
0: power on (default).
1: power off.
In CMOS mode, Bits[7:5] select the output polarity of each CMOS output.
In LVDS mode, only Bit 5 determines LVDS polarity.
7
6
5
OUT7A (CMOS)
OUT7B (CMOS)
OUT7 (LVDS)
0
0
0
Noninverting
Inverting
Noninverting
0
1
0
Noninverting
Noninverting
Noninverting (default)
1
0
0
Inverting
Inverting
Noninverting
1
1
0
Inverting
Noninverting
Noninverting
0
0
1
Inverting
Noninverting
Inverting
0
1
1
Inverting
Inverting
Inverting
1
0
1
Noninverting
Noninverting
Inverting
1
1
1
Noninverting
Inverting
Inverting
In CMOS mode, turns on/off the CMOS B output. There is no effect in LVDS mode.
0: turn off the CMOS B output (default).
1: turn on the CMOS B output.
Selects LVDS or CMOS logic levels.
0: LVDS (default).
1: CMOS.
Rev. C | Page 72 of 80
Data Sheet
Reg.
Addr.
(Hex)
0x143
Bits
[2:1]
Name
OUT9 LVDS output current
0
OUT9 power-down
AD9516-0
Description
Sets output current level in LVDS mode. This has no effect in CMOS mode.
2
1
Current (mA)
Recommended Termination (Ω)
0
0
1.75
100
0
1
3.5
100 (default)
1
0
5.25
50
1
1
7
50
Power-down output (LVDS/CMOS).
0: power on.
1: power off (default).
Table 58. LVPECL Channel Dividers
Reg.
Addr.
(Hex)
0x190
0x191
0x192
0x193
0x194
Bits
[7:4]
Name
Divider 0 low cycles
[3:0]
Divider 0 high cycles
7
Divider 0 bypass
6
Divider 0 nosync
5
Divider 0 force high
4
Divider 0 start high
[3:0]
1
Divider 0 phase offset
Divider 0 direct to output
0
Divider 0 DCCOFF
[7:4]
Divider 1 low cycles
[3:0]
Divider 1 high cycles
7
Divider 1 bypass
6
Divider 1 nosync
5
Divider 1 force high
Description
Number of clock cycles (minus 1) of the divider input during which divider output stays low.
A value of 0x0 means that the divider is low for one input clock cycle (default = 0x0).
Number of clock cycles (minus 1) of the divider input during which divider output stays high.
A value of 0x0 means that the divider is high for one input clock cycle (default = 0x0).
Bypasses and powers down the divider; routes input to divider output.
0: uses divider.
1: bypasses divider (default).
Nosync.
0: obeys chip-level SYNC signal (default).
1: ignores chip-level SYNC signal.
Forces divider output to high. This requires that nosync (Bit 6) also be set.
0: divider output forced to low (default).
1: divider output forced to high.
Selects clock output to start high or start low.
0: starts low (default).
1: starts high.
Phase offset (default = 0x0).
Connect OUT0 and OUT1 to Divider 0 or directly to VCO or CLK.
0: OUT0 and OUT1 are connected to Divider 0 (default).
1: If Register 0x1E1[1:0] = 10b, the VCO is routed directly to OUT0 and OUT1.
If Register 0x1E1[1:0] = 00b, the CLK is routed directly to OUT0 and OUT1.
If Register 0x1E1[1:0] = 01b, there is no effect.
Duty-cycle correction function.
0: enables duty-cycle correction (default).
1: disables duty-cycle correction.
Number of clock cycles of the divider input during which divider output stays low.
A value of 0x0 means that the divider is low for one input clock cycle (default = 0x0).
Number of clock cycles (minus 1) of the divider input during which divider output stays high.
A value of 0x0 means that the divider is high for one input clock cycle (default = 0x0).
Bypasses and powers down the divider; routes input to divider output.
0: uses divider (default).
1: bypasses divider.
Nosync.
0: obeys chip-level SYNC signal (default).
1: ignores chip-level SYNC signal.
Forces divider output to high. This requires that nosync (Bit 6) also be set.
0: divider output forced to low (default).
1: divider output forced to high.
Rev. C | Page 73 of 80
AD9516-0
Data Sheet
Reg.
Addr.
(Hex)
0x194
Bits
4
Name
Divider 1 start high
0x195
[3:0]
1
Divider 1 phase offset
Divider 1 direct to output
0
Divider 1 DCCOFF
[7:4]
Divider 2 low cycles
[3:0]
Divider 2 high cycles
7
Divider 2 bypass
6
Divider 2 nosync
5
Divider 2 force high
4
Divider 2 start high
[3:0]
1
Divider 2 phase offset
Divider 2 direct to output
0
Divider 2 DCCOFF
0x196
0x197
0x198
Description
Selects clock output to start high or start low.
0: starts low (default).
1: starts high.
Phase offset (default = 0x0).
Connects OUT2 and OUT3 to Divider 1 or directly to VCO or CLK.
0: OUT2 and OUT3 are connected to Divider 1 (default).
1: If Register 0x1E1[1:0] = 10b, the VCO is routed directly to OUT2 and OUT3.
If Register 0x1E1[1:0] = 00b, the CLK is routed directly to OUT2 and OUT3.
If Register 0x1E1[1:0] = 01b, there is no effect.
Duty-cycle correction function.
0: enables duty-cycle correction (default).
1: disables duty-cycle correction.
Number of clock cycles (minus 1) of the divider input during which divider output stays low.
A value of 0x0 means that the divider is low for one input clock cycle (default = 0x0).
Number of clock cycles (minus 1) of the divider input during which divider output stays high.
A value of 0x0 means that the divider is high for one input clock cycle (default = 0x0).
Bypasses and powers down the divider; routes input to divider output.
0: uses divider.
1: bypasses divider (default).
Nosync.
0: obeys chip-level SYNC signal (default).
1: ignores chip-level SYNC signal.
Forces divider output to high. This requires that nosync (Bit 6) also be set.
0: divider output forced to low (default).
1: divider output forced to high.
Selects clock output to start high or start low.
0: starts low (default).
1: starts high.
Phase offset (default = 0x0).
Connects OUT4 and OUT5 to Divider 2 or directly to VCO or CLK.
0: OUT4 and OUT5 are connected to Divider 2 (default).
1: If Register 0x1E1[1:0] = 10b, the VCO is routed directly to OUT4 and OUT5.
If Register 0x1E1[1:0] = 00b, the CLK is routed directly to OUT4 and OUT5.
If Register 0x1E1[1:0] = 01b, there is no effect.
Duty-cycle correction function.
0: enables duty-cycle correction (default).
1: disables duty-cycle correction.
Table 59. LVDS/CMOS Channel Dividers
Reg.
Addr.
(Hex)
0x199
Bits
[7:4]
Name
Low Cycles Divider 3.1
[3:0]
High Cycles Divider 3.1
0x19A
[7:4]
Phase Offset Divider 3.2
0x19B
[3:0]
[7:4]
Phase Offset Divider 3.1
Low Cycles Divider 3.2
[3:0]
High Cycles Divider 3.2
Description
Number of clock cycles (minus 1) of 3.1 divider input during which 3.1 output stays low.
A value of 0x0 means that the divider is low for one input clock cycle (default = 0x0).
Number of clock cycles (minus 1) of 3.1 divider input during which 3.1 output stays high. A value of
0x0 means that the divider is high for one input clock cycle (default = 0x0).
Refer to LVDS/CMOS channel divider function description (default = 0x0).
Refer to LVDS/CMOS channel divider function description (default = 0x0).
Number of clock cycles (minus 1) of 3.2 divider input during which 3.2 output stays low.
A value of 0x0 means that the divider is low for one input clock cycle (default = 0x0).
Number of clock cycles (minus 1)of 3.2 divider input during which 3.2 output stays high. A value
of 0x0 means that the divider is high for one input clock cycle (default = 0x0).
Rev. C | Page 74 of 80
Data Sheet
Reg.
Addr.
(Hex)
0x19C
Bits
5
Name
Bypass Divider 3.2
4
Bypass Divider 3.1
3
Divider 3 nosync
2
Divider 3 force high
1
Start High Divider 3.2
0
Start High Divider 3.1
0x19D
0
Divider 3 DCCOFF
0x19E
[7:4]
Low Cycles Divider 4.1
[3:0]
High Cycles Divider 4.1
[7:4]
[3:0]
[7:4]
Phase Offset Divider 4.2
Phase Offset Divider 4.1
Low Cycles Divider 4.2
[3:0]
High Cycles Divider 4.2
5
Bypass Divider 4.2
4
Bypass Divider 4.1
3
Divider 4 nosync
2
Divider 4 force high
1
Start High Divider 4.2
0
Start High Divider 4.1
0
Divider 4 DCCOFF
0x19F
0x1A0
0x1A1
0x1A2
AD9516-0
Description
Bypasses (and powers down) 3.2 divider logic, routes clock to 3.2 output.
0: does not bypass (default).
1: bypasses.
Bypasses (and powers down) 3.1 divider logic, routes clock to 3.1 output.
0: does not bypass 3.1 divider logic (default).
1: bypasses 3.1 divider logic.
Nosync.
0: obeys chip-level SYNC signal (default).
1: ignores chip-level SYNC signal.
Force Divider 3 output high. Requires that nosync also be set.
0: forces low (default).
1: forces high.
Divider 3.2 starts high/low.
0: starts low (default).
1: starts high.
Divider 3.1 starts high/low.
0: starts low (default).
1: starts high.
Duty-cycle correction function.
0: enables duty-cycle correction (default).
1: disables duty-cycle correction.
Number of clock cycles (minus 1) of 4.1 divider input during which 4.1 output stays low.
A value of 0x0 means that the divider is low for one input clock cycle (default = 0x0).
Number of clock cycles (minus 1) of 4.1 divider input during which 4.1 output stays high.
A value of 0x0 means that the divider is high for one input clock cycle (default = 0x0).
Refer to LVDS/CMOS channel divider function description (default = 0x0).
Refer to LVDS/CMOS channel divider function description (default = 0x0).
Number of clock cycles (minus 1) of 4.2 divider input during which 4.2 output stays low.
A value of 0x0 means that the divider is low for one input clock cycle (default = 0x0).
Number of clock cycles (minus 1) of 4.2 divider input during which 4.2 output stays high.
A value of 0x0 means that the divider is high for one input clock cycle (default = 0x0).
Bypasses (and powers down) 4.2 divider logic; route clock to 4.2 output.
0: does not bypass 4.2 divider logic (default).
1: bypasses 4.2 divider logic.
Bypasses (and powers down) 4.1 divider logic; route clock to 4.1 output.
0: does not bypass 4.1 divider logic (default).
1: bypasses 4.1 divider logic.
Nosync.
0: obeys chip-level SYNC signal (default).
1: ignores chip-level SYNC signal.
Forces Divider 4 output high. Requires that nosync also be set.
0: forces low (default).
1: forces high.
Divider 4.2 starts high/low.
0: starts low (default).
1: starts high.
Divider 4.1 starts high/low.
0: starts low (default).
1: starts high.
Duty-cycle correction function.
0: enables duty-cycle correction (default).
1: disables duty-cycle correction.
Rev. C | Page 75 of 80
AD9516-0
Data Sheet
Table 60. VCO Divider and CLK Input
Reg.
Addr
(Hex)
0x1E0
Bits
[2:0]
Name
VCO divider
0x1E1
4
Power down clock input section
3
Power down VCO clock interface
2
Power down VCO and CLK
1
Select VCO or CLK
0
Bypass VCO divider
0x1E1
Description
2 1 0
0 0 0
0 0 1
0 1 0
0 1 1
1 0 0
1 0 1
Divide
2.
3.
4 (default).
5.
6.
Output static. Note that setting the VCO divider static should occur only
after VCO calibration.
1 1 0 Output static. Note that setting the VCO divider static should occur only
after VCO calibration.
1 1 1 Output static. Note that setting the VCO divider static should occur only
after VCO calibration.
Powers down the clock input section (including CLK buffer, VCO divider, and CLK tree).
0: normal operation (default).
1: power-down.
Powers down the interface block between VCO and clock distribution.
0: normal operation (default).
1: power-down.
Powers down both VCO and CLK input.
0; normal operation (default).
1: power-down.
Selects either the VCO or the CLK as the input to VCO divider.
0: selects external CLK as input to VCO divider (default).
1: selects VCO as input to VCO divider; cannot bypass VCO divider when this is selected.
Bypasses or uses the VCO divider.
0: uses VCO divider (default).
1: bypasses VCO divider; cannot select VCO as input when this is selected.
Table 61. System
Reg.
Addr.
(Hex)
0x230
Bits
2
Name
Power down SYNC
1
Power down distribution reference
0
Soft SYNC
Description
Powers down the SYNC function.
0: normal operation of the SYNC function (default).
1: powers down SYNC circuitry.
Powers down the reference for distribution section.
0: normal operation of the reference for the distribution section (default).
1: powers down the reference for the distribution section.
The soft SYNC bit works the same as the SYNC pin, except that the polarity of the bit
is reversed. That is, a high level forces selected channels into a predetermined static
state, and a 1-to-0 transition triggers a SYNC.
0: same as SYNC high (default).
1: same as SYNC low.
Table 62. Update All Registers
Reg.
Addr
(Hex)
0x232
Bits
0
Name
Update all registers
Description
This bit must be set to 1 to transfer the contents of the buffer registers into the active
registers. This bit is self-clearing; that is, it does not have to be set back to 0.
1 (self-clearing): updates all active registers to the contents of the buffer registers.
Rev. C | Page 76 of 80
Data Sheet
AD9516-0
APPLICATIONS INFORMATION
Within the AD9516 family, lower VCO frequencies generally
result in slightly lower jitter. The difference in integrated jitter
(from 12 kHz to 20 MHz offset) for the same output frequency is
usually less than 150 fs over the entire VCO frequency range
(1.45 GHz to 2.95 GHz) of the AD9516 family. If the desired
frequency plan can be achieved with a version of the AD9516
that has a lower VCO frequency, choosing the lower frequency
part results in the lowest phase noise and the lowest jitter. However,
choosing a higher VCO frequency may result in more flexibility
in frequency planning.
Choosing a nominal charge pump current in the middle of the
allowable range as a starting point allows the designer to increase or
decrease the charge pump current and, thus, allows the designer
to fine-tune the PLL loop bandwidth in either direction.
ADIsimCLK is a powerful PLL modeling tool that can be
downloaded from www.analog.com. It is a very accurate tool for
determining the optimal loop filter for a given application.
USING THE AD9516 OUTPUTS FOR ADC CLOCK
APPLICATIONS
Any high speed ADC is extremely sensitive to the quality of its
sampling clock. An ADC can be thought of as a sampling mixer,
and any noise, distortion, or timing jitter on the clock is combined
with the desired signal at the analog-to-digital output. Clock
integrity requirements scale with the analog input frequency
and resolution, with higher analog input frequency applications
at ≥14-bit resolution being the most stringent. The theoretical
SNR of an ADC is limited by the ADC resolution and the jitter
on the sampling clock.




where:
fA is the highest analog frequency being digitized.
tJ is the rms jitter on the sampling clock.
Figure 70 shows the required sampling clock jitter as a function
of the analog frequency and effective number of bits (ENOB).
110
18
1
SNR = 20log 2πf t
A J
100
16
90
tJ =
100
fS
200
f
80
14
S
400
f
70
12
S
1ps
60
2ps
10
10p
s
8
ENOB
The AD9516 has the following four frequency dividers: the
reference (or R) divider, the feedback (or N) divider, the VCO
divider, and the channel divider. When trying to achieve a
particularly difficult frequency divide ratio requiring a large
amount of frequency division, some of the frequency division
can be done by either the VCO divider or the channel divider,
thus allowing a higher phase detector frequency and more
flexibility in choosing the loop bandwidth.
 1
SNR(dB) = 20 × log 
 2πf t
A J

50
40
6
30
10
100
1k
fA (MHz)
06419-044
The AD9516 is a highly flexible PLL. When choosing the PLL
settings and version of the AD9516, keep in mind the following
guidelines.
Considering an ideal ADC of infinite resolution, where the step
size and quantization error can be ignored, the available SNR
can be expressed approximately by
SNR (dB)
FREQUENCY PLANNING USING THE AD9516
Figure 70. SNR and ENOB vs. Analog Input Frequency
See the AN-756 Application Note, Sampled Systems and the Effects
of Clock Phase Noise and Jitter; and the AN-501 Application Note,
Aperture Uncertainty and ADC System Performance, at
www.analog.com.
Many high performance ADCs feature differential clock inputs
to simplify the task of providing the required low jitter clock on
a noisy PCB. (Distributing a single-ended clock on a noisy PCB
may result in coupled noise on the sample clock. Differential
distribution has inherent common-mode rejection that can
provide superior clock performance in a noisy environment.)
The AD9516 features both LVPECL and LVDS outputs that
provide differential clock outputs, which enable clock solutions
that maximize converter SNR performance. The input
requirements of the ADC (differential or single-ended, logic
level, termination) should be considered when selecting the best
clocking/converter solution.
Rev. C | Page 77 of 80
AD9516-0
Data Sheet
LVPECL CLOCK DISTRIBUTION
The LVPECL outputs of the AD9516 provide the lowest jitter
clock signals that are available from the AD9516. The LVPECL
outputs (because they are open emitter) require a dc termination
to bias the output transistors. The simplified equivalent circuit
in Figure 59 shows the LVPECL output stage.
In most applications, an LVPECL far-end Thevenin termination
(see Figure 71) or Y-termination (see Figure 72) is recommended.
In each case, the VS of the receiving buffer should match the
VS_LVPECL. If it does not, ac coupling is recommended (see
Figure 73).
The resistor network is designed to match the transmission line
impedance (50 Ω) and the switching threshold (VS − 1.3 V).
VS_DRV
50Ω
LVPECL
127Ω
127Ω
SINGLE-ENDED
(NOT COUPLED)
50Ω
VS
LVPECL
83Ω
83Ω
Figure 71. DC-Coupled 3.3 V LVPECL, Far-End Thevenin Termination
VS_LVPECL
VS = 3.3V
Z0 = 50Ω
50Ω
50Ω
50Ω
LVPECL
06419-147
Z0 = 50Ω
LVPECL
LVDS CLOCK DISTRIBUTION
The AD9516 provides four clock outputs (OUT6 to OUT9) that
are selectable as either CMOS or LVDS level outputs. LVDS is a
differential output option that uses a current mode output stage.
The nominal current is 3.5 mA, which yields 350 mV output swing
across a 100 Ω resistor. An output current of 7 mA is also available
in cases where a larger output swing is required. The LVDS
output meets or exceeds all ANSI/TIA/EIA-644 specifications.
A recommended termination circuit for the LVDS outputs is
shown in Figure 74.
Figure 72. DC-Coupled 3.3 V LVPECL, Y-Termination
VS_LVPECL
Thevenin-equivalent termination uses a resistor network to provide
50 Ω termination to a dc voltage that is below VOL of the LVPECL
driver. In this case, VS_LVPECL on the AD9516 should equal VS
of the receiving buffer. Although the resistor combination shown
in Figure 72 results in a dc bias point of VS_LVPECL − 2 V, the
actual common-mode voltage is VS_LVPECL − 1.3 V because
additional current flows from the AD9516 LVPECL driver through
the pull-down resistor.
The circuit is identical when VS_LVPECL = 2.5 V, except that
the pull-down resistor is 62.5 Ω and the pull-up resistor is 250 Ω.
06419-145
VS_LVPECL
LVPECL Y-termination is an elegant termination scheme that
uses the fewest components and offers both odd- and even-mode
impedance matching. Even-mode impedance matching is an
important consideration for closely coupled transmission lines
at high frequencies. Its main drawback is that it offers limited
flexibility for varying the drive strength of the emitter-follower
LVPECL driver. This can be an important consideration when
driving long trace lengths but is usually not an issue. In the case
shown in Figure 72, where VS_LVPECL = 2.5 V, the 50 Ω
termination resistor that is connected to ground should be
changed to 19 Ω.
VS
VS
VS
0.1nF
LVDS
LVPECL
200Ω
Figure 73. AC-Coupled LVPECL with Parallel Transmission Line
100Ω
100Ω
DIFFERENTIAL (COUPLED)
LVDS
06419-047
200Ω
100Ω DIFFERENTIAL
100Ω
(COUPLED)
0.1nF TRANSMISSION LINE
06419-146
LVPECL
Figure 74. LVDS Output Termination
See the AN-586 Application Note, LVDS Data Outputs for HighSpeed Analog-to-Digital Converters for more information on LVDS.
Rev. C | Page 78 of 80
Data Sheet
AD9516-0
The AD9516 provides four clock outputs (OUT6 to OUT9)
that are selectable as either CMOS or LVDS level outputs.
When selected as CMOS, each output becomes a pair of CMOS
outputs, each of which can be individually turned on or off and
set as noninverting or inverting. These outputs are 3.3 V CMOS
compatible.
Whenever single-ended CMOS clocking is used, some of the
following general guidelines should be used.
Point-to-point nets should be designed such that a driver has
only one receiver on the net, if possible. This allows for simple
termination schemes and minimizes ringing due to possible
mismatched impedances on the net. Series termination at the
source is generally required to provide transmission line
matching and/or to reduce current transients at the driver.
The value of the resistor is dependent on the board design and
timing requirements (typically 10 Ω to 100 Ω is used). CMOS
outputs are also limited in terms of the capacitive load or trace
length that they can drive. Typically, trace lengths less than
3 inches are recommended to preserve signal rise/fall times and
preserve signal integrity.
10Ω
VS
CMOS
CMOS
50Ω
100Ω
CMOS
Figure 76. CMOS Output with Far-End Termination
Because of the limitations of single-ended CMOS clocking,
consider using differential outputs when driving high speed
signals over long traces. The AD9516 offers both LVPECL and
LVDS outputs that are better suited for driving long traces
where the inherent noise immunity of differential signaling
provides superior performance for clocking converters.
60.4Ω
(1.0 INCH)
MICROSTRIP
10Ω
100Ω
06419-076
CMOS
Termination at the far-end of the PCB trace is a second option.
The CMOS outputs of the AD9516 do not supply enough
current to provide a full voltage swing with a low impedance
resistive, far-end termination, as shown in Figure 76. The farend termination network should match the PCB trace impedance
and provide the desired switching point. The reduced signal
swing may still meet receiver input requirements in some
applications. This can be useful when driving long trace
lengths on less critical nets.
06419-077
CMOS CLOCK DISTRIBUTION
Figure 75. Series Termination of CMOS Output
Rev. C | Page 79 of 80
AD9516-0
Data Sheet
OUTLINE DIMENSIONS
9.10
9.00 SQ
8.90
0.30
0.25
0.18
0.60 MAX
0.60
MAX
64 1
49
48
PIN 1
INDICATOR
PIN 1
INDICATOR
8.85
8.75 SQ
8.65
0.50
BSC
0.50
0.40
0.30
33
32
0.25 MIN
7.50 REF
0.80 MAX
0.65 TYP
0.05 MAX
0.02 NOM
SEATING
PLANE
16
0.20 REF
FOR PROPER CONNECTION OF
THE EXPOSED PAD, REFER TO
THE PIN CONFIGURATION AND
FUNCTION DESCRIPTIONS
SECTION OF THIS DATA SHEET.
COMPLIANT TO JEDEC STANDARDS MO-220-VMMD-4
06-12-2012-C
12° MAX
17
BOTTOM VIEW
TOP VIEW
1.00
0.85
0.80
6.35
6.20 SQ
6.05
EXPOSED
PAD
Figure 77. 64-Lead Lead Frame Chip Scale Package [LFCSP_VQ]
9 mm × 9 mm Body, Very Thin Quad
CP-64-4
Dimensions shown in millimeters
ORDERING GUIDE
Model 1
AD9516-0BCPZ
AD9516-0BCPZ-REEL7
AD9516-0/PCBZ
1
Temperature Range
−40°C to +85°C
−40°C to +85°C
Package Description
64-Lead Lead Frame Chip Scale Package (LFCSP_VQ)
64-Lead Lead Frame Chip Scale Package (LFCSP_VQ)
Evaluation Board
Z = RoHS Compliant Part.
©2007–2013 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D06419-0-2/13(C)
Rev. C | Page 80 of 80
Package Option
CP-64-4
CP-64-4