Quad/Octal Input Network Clock Generator/Synchronizer AD9548 Data Sheet FEATURES APPLICATIONS Supports Stratum 2 stability in holdover mode Supports reference switchover with phase build-out Supports hitless reference switchover Auto/manual holdover and reference switchover 4 pairs of reference input pins with each pair configurable as a single differential input or as 2 independent singleended inputs Input reference frequencies from 1 Hz to 750 MHz Reference validation and frequency monitoring (1 ppm) Programmable input reference switchover priority 30-bit programmable input reference divider 4 pairs of clock output pins with each pair configurable as a single differential LVDS/LVPECL output or as 2 singleended CMOS outputs Output frequencies up to 450 MHz 30-bit integer and 10-bit fractional programmable feedback divider Programmable digital loop filter covering loop bandwidths from 0.001 Hz to 100 kHz Optional low noise LC-VCO system clock multiplier Optional crystal resonator for system clock input On-chip EEPROM to store multiple power-up profiles Software controlled power-down 88-lead LFCSP package Network synchronization Cleanup of reference clock jitter GPS 1 pulse per second synchronization SONET/SDH clocks up to OC-192, including FEC Stratum 2 holdover, jitter cleanup, and phase transient control Stratum 3E and Stratum 3 reference clocks Wireless base station controllers Cable infrastructure Data communications GENERAL DESCRIPTION The AD9548 provides synchronization for many systems, including synchronous optical networks (SONET/SDH). The AD9548 generates an output clock synchronized to one of up to four differential or eight single-ended external input references. The digital PLL allows for reduction of input time jitter or phase noise associated with the external references. The AD9548 continuously generates a clean (low jitter), valid output clock even when all references have failed by means of a digitally controlled loop and holdover circuitry. The AD9548 operates over an industrial temperature range of −40°C to +85°C. FUNCTIONAL BLOCK DIAGRAM ANALOG FILTER STABLE SOURCE AD9548 CLOCK DISTRIBUTION CLOCK MULTIPLIER CHANNEL 0 DIVIDER CHANNEL 1 DIVIDER DIGITAL PLL CHANNEL 2 DIVIDER DAC REFERENCE INPUTS AND MONITOR MUX CHANNEL 3 DIVIDER SYNC EEPROM STATUS AND CONTROL PINS 08022-001 SERIAL CONTROL INTERFACE (SPI or I2C) Figure 1. Rev. G Document Feedback Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 ©2009–2014 Analog Devices, Inc. All rights reserved. Technical Support www.analog.com AD9548 Data Sheet TABLE OF CONTENTS Features .............................................................................................. 1 Digital PLL (DPLL) Core .......................................................... 32 Applications ....................................................................................... 1 Direct Digital Synthesizer ......................................................... 34 General Description ......................................................................... 1 Tuning Word Processing ........................................................... 35 Functional Block Diagram .............................................................. 1 Loop Control State Machine ..................................................... 36 Revision History ............................................................................... 3 System Clock Inputs................................................................... 37 Specifications..................................................................................... 4 SYSCLK PLL Multiplier............................................................. 38 Supply Voltage ............................................................................... 4 Clock Distribution ..................................................................... 40 Supply Current .............................................................................. 4 Status and Control .......................................................................... 44 Power Dissipation ......................................................................... 4 Multifunction Pins (M0 to M7) ............................................... 44 Logic Inputs (M7 to M0, RESET, TDI, TCLK, TMS) .............. 5 IRQ Pin ........................................................................................ 45 Logic Outputs (M7 to M0, IRQ, TDO) ..................................... 5 Watchdog Timer ......................................................................... 46 System Clock Inputs (SYSCLKP/SYSCLKN) ........................... 5 EEPROM ..................................................................................... 46 Distribution Clock Inputs (CLKINP/CLKINN) ...................... 6 Serial Control Port ......................................................................... 51 Reference Inputs (REFA/REFAA to REFD/REFDD) .............. 7 SPI/I2C Port Selection................................................................ 51 Reference Monitors ...................................................................... 7 SPI Serial Port Operation .......................................................... 51 Reference Switchover Specifications .......................................... 8 I2C Serial Port Operation .......................................................... 56 Distribution Clock Outputs (OUT0 to OUT3) ........................ 8 Input/Output Programming Registers ........................................ 59 DAC Output Characteristics (DACOUTP/DACOUTN) ....... 9 Buffered/Active Registers .......................................................... 59 Time Duration of Digital Functions ........................................ 10 Autoclear Registers ...................................................................... 59 Digital PLL .................................................................................. 10 Register Access Restrictions ........................................................ 59 Digital PLL Lock Detection ...................................................... 10 Register Map ................................................................................... 60 Holdover Specifications ............................................................. 10 Register Map Bit Descriptions ...................................................... 70 Serial Port Specifications—SPI Mode ...................................... 11 Serial Port Specifications—I C Mode ...................................... 11 Serial Port Configuration (Register 0x0000 to Register 0x0005) ......................................................................... 70 Jitter Generation ......................................................................... 12 System Clock (Register 0x0100 to Register 0x0108) ............. 71 Absolute Maximum Ratings.......................................................... 14 General Configuration (Register 0x0200 to Register 0x0214) .. 72 ESD Caution ................................................................................ 14 DPLL Configuration (Register 0x0300 to Register 0x031B) 75 Pin Configuration and Function Descriptions ........................... 15 Clock Distribution Output Configuration (Register 0x0400 to Register 0x0419)........................................................................... 77 2 Typical Performance Characteristics ........................................... 18 Input/Output Termination Recommendations .......................... 23 Reference Input Configuration (Register 0x0500 to Register 0x0507) ......................................................................... 81 Getting Started ................................................................................ 24 Profile Registers (Register 0x0600 to Register 0x07FF) ........ 83 Power-On Reset .......................................................................... 24 Operational Controls (Register 0x0A00 to Register 0x0A10) ... 92 Initial M0 to M7 Pin Programming ......................................... 24 Clock Part Serial ID (Register 0x0C00 to Register 0x0C07) 97 Device Register Programming .................................................. 24 Status Readback (Register 0x0D00 to Register 0x0D19) ...... 97 Theory of Operation ...................................................................... 26 Overview...................................................................................... 26 Reference Clock Inputs .............................................................. 27 Nonvolatile Memory (EEPROM) Control (Register 0x0E00 to Register 0x0E03) ........................................................................ 101 Reference Monitors .................................................................... 27 EEPROM Storage Sequence (Register 0x0E10 to Register 0x0E3F) ........................................................................ 101 Reference Profiles ....................................................................... 28 Power Supply Partitions............................................................... 106 Reference Switchover ................................................................. 30 3.3 V Supplies............................................................................ 106 Rev. G | Page 2 of 111 Data Sheet AD9548 1.8 V Supplies ........................................................................... 106 Calculation of the Register Values .......................................110 Thermal Performance .................................................................. 107 Calculation of the Register Values .......................................110 Calculating Digital Filter Coefficients ....................................... 108 Outline Dimensions ......................................................................111 Calculation of the Register Values ..................................... 109 Ordering Guide .........................................................................111 Calculation of the β Register Values ...................................... 109 REVISION HISTORY 12/14—Rev. F to Rev. G Changes to Figure 7 Caption to Figure 12 Caption ....................19 Changes to System Clock Period Section ....................................39 Changes to Table 36 ........................................................................62 6/14—Rev. E to Rev. F Changes to Table 21 ........................................................................15 Added Figure 34; Renumbered Sequentially ...............................23 Changed Initial Pin Programming Section to Initial M0 to M7 Pin Programming Section ..............................................................24 Changes to Frequency Tuning Word History Section ...............36 Added Disabling Accidental Automatic EEPROM Download Section ..............................................................................................48 Changes to Buffered/Active Registers Section ............................59 Changes to Register Map Section, Opt Column, Table 36 ........60 Changes to Table 65 ........................................................................76 12/13—Rev. D to Rev. E Changes to Calculating Digital Filter Coefficients Section .....109 Changes to Calculation of the Register Values Section ........110 6/13—Rev. C to Rev. D Change to Table 16 ..........................................................................10 Changes to IRQ Pin Section ..........................................................46 Changes to Programming the EEPROM to Include a Clock Part ID Section ................................................................................50 Changes to Bit 0, Table 121 ............................................................94 Changes to Status Readback (Register 0x0D00 to Register 0x0D19) Section ..............................................................................98 2/13—Rev. B to Rev. C Change to Pin 53, Description Column, Table 21 ......................17 Added Figure 33, Renumbered Sequentially ...............................23 Changes to Automatic Priority-Based Reference Switchover Section; Added Table 23, Renumbered Sequentially ......................30 Changes to Low Loop Bandwidth Applications Using a TCXO/OCXO Section ....................................................................37 Changes to EEPROM Upload Section and EEPROM Download Section ...........................................................................48 Added Programming the EEPROM to Include a Clock Part ID Section ................................................................................50 Changes to Read Section ................................................................ 52 Added Figure 56 .............................................................................. 54 Changes to tC Parameter, Description Column, Table 33 .......... 55 Added Table Summary Statement, Table 36 ................................ 60 Changes to Table 36 ........................................................................ 60 Added User Scratch Pad (Eight Bytes), Address 0x0C00 to Address 0x0C07, Table 36 .............................................................. 67 Changes to Table 39 ........................................................................ 70 Added Clock Part Serial ID (Register 0x0C00 to Register 0x0C07) Section and Table 131 ...................................... 98 Changes to Table 142 .................................................................... 102 Added Table 153 ............................................................................ 105 Added Table 154 ............................................................................ 106 7/11—Rev. A to Rev. B Changed AD9584 to AD9548........................................................ 32 Changed 437,749,988,378,041 to 43,774,988,378,041 ................ 34 Change to Calculating Digital Filter Coefficients Section....... 107 10/10—Rev. 0 to Rev. A Changes to Timing Parameter, Table 17 ...................................... 11 Added Low Loop Bandwidth Applications Using a TCXO/OCXO Section and Choosing a System Clock Oscillator Frequency Section .............................................................................................. 37 Moved System Clock Period Section ............................................ 39 Changes to Addr 0002, Table 35.................................................... 60 Changes to Addr 0600, Table 35.................................................... 62 Changes to Addr 0632, Table 35.................................................... 63 Changes to Addr 0680, Table 35.................................................... 64 Changes to Addr 06B2, Table 35 ................................................... 65 Changes to Address 0002 Description, Table 38 ......................... 70 Changes to Bit 7 and Bit 6, Table 78 ............................................. 83 Changes to Address 0629 and Address 062A, Table 87 and Bit 7 and Bit 6, Table 88 ........................................................................... 85 Changes to Address 065B and Address 065C, Table 97 and Bit 7 and Bit 6, Table 98 ........................................................................... 87 Changes to Address 06A9 and Address 06AA, Table 107 ......... 89 Changes to Bit 7 and Bit 6, Table 108 ........................................... 90 Changes to Address 06DB and Address 06DC, Table 117......... 92 4/09—Revision 0: Initial Version Rev. G | Page 3 of 111 AD9548 Data Sheet SPECIFICATIONS Minimum (min) and maximum (max) values apply for the full range of supply voltage and operating temperature variations. Typical (typ) values apply for AVDD3 = DVDD_I/O = 3.3 V; AVDD = DVDD = 1.8 V; TA= 25°C; IDAC = 20 mA (full scale), unless otherwise noted. SUPPLY VOLTAGE Table 1. Parameter SUPPLY VOLTAGE DVDD3 DVDD AVDD3 3.3 V Supply (Typical) 1.8 V Supply (Alternative) AVDD Min Typ Max Unit Test Conditions/Comments 3.135 1.71 3.135 3.135 1.71 1.71 3.30 1.80 3.30 3.30 1.80 1.80 3.465 1.89 3.465 3.465 1.89 1.89 V V V V V V Pin 7, Pin 82 Pin 1, Pin 6, Pin 12, Pin 14, Pin 15, Pin 77, Pin 83, Pin 88 Pin 21, Pin 22, Pin 47, Pin 60, Pin 66, Pin 67, Pin 73 Pin 31, Pin 37, Pin 38, Pin 44 Pin 31, Pin 37, Pin 38, Pin 44 Pin 23, Pin 24, Pin 29, Pin 34, Pin 41, Pin 50, Pin 55, Pin 59, Pin 63, Pin 70, Pin 74 SUPPLY CURRENT The test conditions for the maximum (max) supply current are the same as the test conditions for the All Blocks Running parameter of Table 3. The test conditions for the typical (typ) supply current are the same as the test conditions for the Typical Configuration parameter of Table 3. Table 2. Parameter SUPPLY CURRENT IDVDD3 IDVDD IAVDD3 IAVDD3 3.3 V Supply (Typical) 1.8 V Supply (Alternative) IAVDD Min Typ Max Unit Test Conditions/Comments 1.5 190 52 3 215 75 mA mA mA Pin 7, Pin 82 Pin 1, Pin 6, Pin 12, Pin 14, Pin 15, Pin 77, Pin 83, Pin 88 Pin 21, Pin 22, Pin 47, Pin 60, Pin 66, Pin 67, Pin 73 24 24 135 110 110 163 mA mA mA Pin 31, Pin 37, Pin 38, Pin 44 Pin 31, Pin 37, Pin 38, Pin 44 Pin 23, Pin 24, Pin 29, Pin 34, Pin 41, Pin 50, Pin 55, Pin 59, Pin 63, Pin 70, Pin 74 Typ Max Unit Test Conditions/Comments 800 1100 mW All Blocks Running 900 1400 mW Full Power-Down 13 fSYSCLK = 20 MHz1; fS = 1 GHz2; fDDS = 122.88 MHz3; one LVPECL clock distribution output running at 122.88 MHz (all others powered down); one input reference running at 100 MHz (all others powered down) fSYSCLK = 20 MHz1; fS = 1 GHz2; fDDS = 399 MHz3; all clock distribution outputs configured as LVPECL at 399 MHz; all input references configured as differential at 100 MHz; fractional-N active (R = 10, S = 39, U = 9, V = 10) Conditions = typical configuration; no external pull-up or pull-down resistors POWER DISSIPATION Table 3. Parameter POWER DISSIPATION Typical Configuration Min mW Rev. G | Page 4 of 111 Data Sheet Parameter Incremental Power Dissipation AD9548 Min Typ SYSCLK PLL Off Input Reference On Differential Single-Ended Output Distribution Driver On LVDS LVPECL CMOS Max Unit −105 mW 7 13 mW mW 70 75 65 mW mW mW Test Conditions/Comments Conditions = typical configuration; table values show the change in power due to the indicated operation. fSYSCLK = 1 GHz1; high frequency direct input mode. A single 3.3 V CMOS output with a 10 pF load. fSYSCLK is the frequency at the SYSCLKP and SYSCLKN pins. fS is the sample rate of the output DAC. 3 fDDS is the output frequency of the DDS. 1 2 LOGIC INPUTS (M7 TO M0, RESET, TDI, TCLK, TMS) Table 4. Parameter LOGIC INPUTS (M7 to M0, RESET, TDI, TCLK, TMS) Input High Voltage (VIH) Input Low Voltage (VIL) Input Current (IINH, IINL) Input Capacitance (CIN) Min Typ Max Unit 0.8 ±200 V V µA pF Max Unit Test Conditions/Comments 0.4 V V 1 1 μA μA IOH = 1 mA IOL = 1 mA Open-drain mode VOH = 3.3 V VOL =-0 V 2.1 ±80 3 Test Conditions/Comments LOGIC OUTPUTS (M7 TO M0, IRQ, TDO) Table 5. Parameter LOGIC OUTPUTS (M7 to M0, IRQ, TDO) Output High Voltage (VOH) Output Low Voltage (VOL) IRQ Leakage Current Active Low Output Mode Active High Output Mode Min Typ 2.7 SYSTEM CLOCK INPUTS (SYSCLKP/SYSCLKN) Table 6. Parameter SYSTEM CLOCK PLL BYPASSED Input Frequency Range Minimum Input Slew Rate Duty Cycle Common-Mode Voltage Differential Input Voltage Sensitivity Input Capacitance Input Resistance Min Typ 500 1000 40 Max Unit 1000 MHz V/μs 1.2 60 % V mV p-p 2 2.5 pF kΩ 100 Rev. G | Page 5 of 111 Test Conditions/Comments Minimum limit imposed for jitter performance Internally generated Minimum voltage across pins required to ensure switching between logic states; the instantaneous voltage on either pin must not exceed the supply rails; can accommodate single-ended input by ac grounding unused input Single-ended, each pin AD9548 Parameter SYSTEM CLOCK PLL ENABLED PLL Output Frequency Range Phase-Frequency Detector (PFD) Rate Frequency Multiplication Range VCO Gain High Frequency Path Input Frequency Range Minimum Input Slew Rate Frequency Divider Range Common-Mode Voltage Differential Input Voltage Sensitivity Input Capacitance Input Resistance Low Frequency Path Input Frequency Range Minimum Input Slew Rate Common-Mode Voltage Differential Input Voltage Sensitivity Input Capacitance Input Resistance Crystal Resonator Path Crystal Resonator Frequency Range Maximum Crystal Motional Resistance Data Sheet Min Typ 900 6 Max Unit 1000 150 255 MHz MHz Test Conditions/Comments Assumes valid system clock and PFD rates 70 MHz/V 100.1 200 500 1 MHz V/μs 8 1 V mV p-p 3 2.5 pF kΩ 100 3.5 50 100 MHz V/μs 1.2 V mV p-p 3 4 pF kΩ 100 10 50 100 MHz Ω Minimum limit imposed for jitter performance Binary steps (M = 1, 2, 4, 8) Internally generated Minimum voltage across pins required to ensure switching between logic states; the instantaneous voltage on either pin must not exceed the supply rails; can accommodate single-ended input by ac grounding unused input Single-ended, each pin Minimum limit imposed for jitter performance Internally generated Minimum voltage across pins required to ensure switching between logic states; the instantaneous voltage on either pin must not exceed the supply rails; can accommodate single-ended input by ac grounding unused input Single-ended, each pin Fundamental mode, AT cut See the System Clock Inputs section for recommendations DISTRIBUTION CLOCK INPUTS (CLKINP/CLKINN) Table 7. Parameter DISTRIBUTION CLOCK INPUTS (CLKINP/CLKINN) Input Frequency Range Minimum Slew Rate Min Typ 62.5 75 Max Unit 500 MHz V/μs Common-Mode Voltage Differential Input Voltage Sensitivity 100 mV mV p-p Differential Input Power Sensitivity −15 dBm Input Capacitance Input Resistance 700 3 5 Rev. G | Page 6 of 111 pF kΩ Test Conditions/Comments Minimum limit imposed for jitter performance. Internally generated. Capacitive coupling required; can accommodate single-ended input by ac grounding unused input; the instantaneous voltage on either pin must not exceed the supply rails. The same as voltage sensitivity but specified as power into a 50 Ω load. Each pin has a 2.5 kΩ internal dcbias resistance. Data Sheet AD9548 REFERENCE INPUTS (REFA/REFAA TO REFD/REFDD) Table 8. Parameter DIFFERENTIAL OPERATION Frequency Range Sinusoidal Input LVPECL Input LVDS Input Minimum Input Slew Rate Min Typ 10 1 1 40 Max Unit 750 750 × 106 750 × 106 MHz Hz Hz V/μs Common-Mode Input Voltage Differential Input Voltage Sensitivity 2 ±65 V mV Input Resistance Input Capacitance 25 3 kΩ pF Minimum Pulse Width High Minimum Pulse Width Low SINGLE-ENDED OPERATION Frequency Range (CMOS) Minimum Input Slew Rate 620 620 Minimum limit imposed for jitter performance Internally generated Minimum differential voltage across pins required to ensure switching between logic levels; the instantaneous voltage on either pin must not exceed the supply rails ps ps 1 40 Input Voltage High (VIH) 1.2 V to 1.5 V Threshold Setting 1.8 V to 2.5 V Threshold Setting 3.0 V to 3.3 V Threshold Setting Input Voltage Low (VIL) 1.2 V to 1.5 V Threshold Setting 1.8 V to 2.5 V Threshold Setting 3.0 V to 3.3 V Threshold Setting Input Resistance Input Capacitance Minimum Pulse Width High Minimum Pulse Width Low Test Conditions/Comments 250 ×106 0.9 1.2 1.9 Hz V/μs Minimum limit imposed for jitter performance V V V 0.27 0.5 1.0 V V V kΩ pF ns ns 45 3 1.5 1.5 REFERENCE MONITORS Table 9. Parameter REFERENCE MONITORS Reference Monitor Loss of Reference Detection Time Frequency Out-of Range Limits Validation Timer Redetect Timer 1 Min 9.54 × 10−7 0.001 0.001 Typ Max Unit Test Conditions/Comments 1.2 sec 0.1 65.535 65.535 Δf/fREF sec sec Calculated using the nominal phase detector period (NPDP = R/fREF)1 Programmable (lower bound subject to quality of SYSCLK) Programmable in 1 ms increments Programmable in 1 ms increments fREF is the frequency of the active reference; R is the frequency division factor determined by the R-divider. Rev. G | Page 7 of 111 AD9548 Data Sheet REFERENCE SWITCHOVER SPECIFICATIONS Table 10. Parameter REFERENCE SWITCHOVER SPECIFICATIONS Maximum Output Phase Perturbation (Phase Build-Out Switchover) Maximum Time/Time Slope (Hitless Switchover) Min Max Unit Test Conditions/Comments 40 200 ps 65,535 ns/sec Assumes a jitter-free reference; satisfies Telcordia GR-1244-CORE requirements Minimum/maximum values are programmable upper bounds; a minimum value ensures <10% error; satisfies Telcordia GR-1244-CORE requirements 315 Time Required to Switch to a New Reference Hitless Switchover Phase Build-Out Switchover 1 Typ 5 sec 3 sec Calculated using the nominal phase detector period (NPDP = R/fREF)1 Calculated using the nominal phase detector period (NPDP = R/fREF)1 fREF is the frequency of the active reference; R is the frequency division factor determined by the R-divider. DISTRIBUTION CLOCK OUTPUTS (OUT0 TO OUT3) Table 11. Parameter LVPECL MODE Maximum Output Frequency Rise/Fall Time (20% to 80%) Duty Cycle Differential Output Voltage Swing Common-Mode Output Voltage Min Typ 725 180 45 630 AVDD3 − 1.5 770 AVDD3 − 1.3 Max Unit 315 55 910 MHz ps % mV AVDD3 − 1.05 V LVDS MODE Maximum Output Frequency Rise/Fall Time1 (20% to 80%) Duty Cycle Differential Output Voltage Swing Balanced, VOD Short-Circuit Output Current CMOS MODE Maximum Output Frequency 3.3 V Supply Strong Drive Strength Setting Weak Drive Strength Setting 1.8 V Supply 100 Ω termination across output pins Magnitude of voltage across pins; output driver static Output driver static Using internal current setting resistor (nominal 3.12 kΩ) 725 200 40 350 60 MHz ps % 247 454 mV 50 mV 1.375 50 V mV 24 mA Unbalanced, ΔVOD Offset Voltage Common-Mode, VOS Common-Mode Difference, ΔVOS Test Conditions/Comments Using internal current setting resistor 1.125 13 100 Ω termination across the output pair Voltage swing between output pins; output driver static Absolute difference between voltage swing of normal pin and inverted pin; output driver static Output driver static Voltage difference between pins; output driver static Output driver static Weak drive option not supported for operating the CMOS drivers using a 1.8 V supply 10 pF load 250 25 150 MHz MHz MHz Rev. G | Page 8 of 111 Data Sheet Parameter Rise/Fall Time1 (20% to 80%) 3.3 V Supply Strong Drive Strength Setting Weak Drive Strength Setting 1.8 V Supply Duty Cycle Output Voltage High (VOH) AVDD3 = 3.3 V, IOH = 10 mA AVDD3 = 3.3 V, IOH = 1 mA AVDD3 = 1.8 V, IOH = 1 mA Output Voltage Low (VOL) AD9548 Min Max Unit 0.5 8 1.5 2 14.5 2.5 60 ns ns ns % 40 2.6 2.9 1.5 AVDD3 = 3.3 V, IOL = 10 mA AVDD3 = 3.3 V, IOL = 1 mA AVDD3 = 1.8 V, IOL = 1 mA OUTPUT TIMING SKEW Between LVPECL Outputs Between LVDS Outputs Between CMOS 3.3 V Outputs Strong Drive Strength Setting Weak Drive Strength Setting Between CMOS 1.8 V Outputs Between LVPECL Outputs and LVDS Outputs Between LVPECL Outputs and CMOS Outputs ZERO-DELAY TIMING SKEW 1 Typ Test Conditions/Comments 10 pF load 10 pF load Output driver static; strong drive strength setting V V V Output driver static; strong drive strength setting 0.3 0.1 0.1 V V V 14 13 125 138 ps ps 23 24 40 14 240 ps ps ps ps 140 19 ps ±5 ns 10 pF load Rising edge only; any divide value Rising edge only; any divide value Weak drive not supported at 1.8 V Output relative to active input reference; output distribution synchronization to active reference feature enabled; assumes manual phase offset compensation of deterministic latency The listed values are for the slower edge (rise or fall). DAC OUTPUT CHARACTERISTICS (DACOUTP/DACOUTN) Table 12. Parameter DAC OUTPUT CHARACTERISTICS (DACOUTP/DACOUTN) Frequency Range Output Offset Voltage Voltage Compliance Range Output Resistance Min 62.5 VSS − 0.5 Output Capacitance Full-Scale Output Current Gain Error Typ 0.5 50 Max Unit 450 15 MHz mV VSS + 0.5 V Ω 5 20 −12 pF mA +12 Rev. G | Page 9 of 111 % FS Test Conditions/Comments This is the single-ended voltage at either DAC output pin (no external load) when the internal DAC code implies that no current is delivered to that pin. Single-ended, each pin has an internal 50 Ω termination to VSS. Programmable (8 mA to 31 mA; see the DAC Output section). AD9548 Data Sheet TIME DURATION OF DIGITAL FUNCTIONS Table 13. Parameter TIME DURATION OF DIGITAL FUNCTIONS EEPROM-to-Register Download Time Min Typ Max Unit Test Conditions/Comments 25 ms Register-to-EEPROM Upload Time 200 ms Minimum Power-Down Exit Time Maximum Time from Assertion of the RESET pin to the M0 to M7 Pins Entering High Impedance State 10.5 45 μs ns Using default EEPROM storage sequence (see Register 0x0E10 to Register 0x0E3F) Using default EEPROM storage sequence (see Register 0x0E10 to Register 0x0E3F Dependent on loop-filter bandwidth DIGITAL PLL Table 14. Parameter DIGITAL PLL Phase-Frequency Detector (PFD) Input Frequency Range Loop Bandwidth Phase Margin Reference Input (R) Division Factor Integer Feedback (S) Division Factor Fractional Feedback Divide Ratio Min Typ Max Unit Test Conditions/Comments 1 107 Hz Maximum fPFD1: fS/1002 0.001 105 Hz 30 1 8 0 89 230 230 0.999 Degrees Programmable design parameter; maximum fLOOP = fREF/(20R)3 Programmable design parameter 1, 2, …, 1,073,741,824 8, 9, …, 1,073,741,824 Maximum value: 1022/1023 fPFD is the frequency at the input to the phase-frequency detector. fS is the sample rate of the output DAC. 3 fREF is the frequency of the active reference; R is the frequency division factor determined by the R-divider. 1 2 DIGITAL PLL LOCK DETECTION Table 15. Parameter PHASE LOCK DETECTOR Threshold Programming Range Threshold Resolution FREQUENCY LOCK DETECTOR Threshold Programming Range Threshold Resolution Min Typ 0.001 Max Unit 65.5 ns ps 16,700 ns ps Reference-to-feedback period difference Max Unit Test Conditions/Comments ppb Excludes frequency drift of SYSCLK source; excludes frequency drift of input reference prior to entering holdover 1 0.001 1 Test Conditions/Comments HOLDOVER SPECIFICATIONS Table 16. Parameter HOLDOVER SPECIFICATIONS Frequency Accuracy Min Typ <0.01 Rev. G | Page 10 of 111 Data Sheet AD9548 SERIAL PORT SPECIFICATIONS—SPI MODE Table 17. Parameter CS Input Logic 1 Voltage Input Logic 0 Voltage Input Logic 1 Current Input Logic 0 Current Input Capacitance SCLK Input Logic 1 Voltage Input Logic 0 Voltage Input Logic 1 Current Input Logic 0 Current Input Capacitance SDIO As an Input Input Logic 1 Voltage Input Logic 0 Voltage Input Logic 1 Current Input Logic 0 Current Input Capacitance As an Output Output Logic 1 Voltage Output Logic 0 Voltage SDO Output Logic 1 Voltage Output Logic 0 Voltage TIMING SCLK Clock Rate, 1/tCLK Pulse Width High, tHI Pulse Width Low, tLO SDIO to SCLK Setup, tDS SCLK to SDIO Hold, tDH SCLK to Valid SDIO and SDO, tDV CS to SCLK Setup (tS) CS to SCLK Hold (tC) CS Minimum Pulse Width High Min Typ Max Unit 2.0 0.8 30 110 2 V V µA µA pF 2.0 0.8 1 1 2 V V µA µA pF 2.0 0.8 1 1 2 V V µA µA pF Test Conditions/Comments Internal 30 kΩ pull-up resistor Internal 30 kΩ pull-down resistor 2.7 0.4 V V 1 mA load current 1 mA load current 0.4 V V 1 mA load current 1 mA load current 2.7 40 MHz ns ns ns ns ns ns ns ns 10 12 3 0 15 10 0 6 SERIAL PORT SPECIFICATIONS—I2C MODE Table 18. Parameter SDA, SCL (AS INPUT) Input Logic 1 Voltage Input Logic 0 Voltage Input Current Hysteresis of Schmitt Trigger Inputs Pulse Width of Spikes That Must Be Suppressed by the Input Filter, tSP SDA (AS OUTPUT) Output Logic 0 Voltage Output Fall Time from VIHmin to VILmax Min Typ Max Unit 0.3 × DVDD3 +10 V V µA 50 ns 0.4 250 V ns 0.7 × DVDD3 −10 0.015 × DVDD3 20 + 0.1 Cb1 Rev. G | Page 11 of 111 Test Conditions/Comments No internal pull-up/down resistor. For VIN = 10% to 90% DVDD3. IO = 3 mA. 10 pF ≤ Cb ≤ 400 pF. AD9548 Parameter TIMING SCL Clock Rate Bus-Free Time Between a Stop and Start Condition, tBUF Repeated Start Condition Setup Time, tSU; STA Repeated Hold Time Start Condition, tHD; STA Stop Condition Setup Time, tSU; STO Low Period of the SCL Clock, tLO High Period of the SCL Clock, tHI SCL/SDA Rise Time, tR SCL/SDA Fall Time, tF Data Setup Time, tSU; DAT Data Hold Time, tHD; DAT Capacitive Load for Each Bus Line, Cb1 1 Data Sheet Min Typ Max Unit 400 1.3 kHz µs 0.6 0.6 µs µs 0.6 1.3 0.6 20 + 0.1 Cb1 20 + 0.1 Cb1 100 100 µs µs µs ns ns ns ns pF 300 300 400 Test Conditions/Comments After this period, the first clock pulse is generated. Cb is the capacitance (pF) of a single bus line. JITTER GENERATION Table 19. Parameter JITTER GENERATION fREF = 1 Hz1; fDDS = 122.88 MHz2; fLOOP = 0.01 Hz3 Min Typ Max Unit Bandwidth: 100 Hz to 61 MHz Bandwidth: 5 kHz to 20 MHz Bandwidth: 20 kHz to 80 MHz Bandwidth: 50 kHz to 80 MHz Bandwidth: 4 MHz to 80 MHz fREF = 8 kHz1; fDDS = 155.52 MHz2; fLOOP = 100 Hz3 0.81 0.73 0.79 0.78 0.37 ps rms ps rms ps rms ps rms ps rms Bandwidth: 100 Hz to 77 MHz Bandwidth: 5 kHz to 20 MHz Bandwidth: 20 kHz to 80 MHz Bandwidth: 50 kHz to 80 MHz Bandwidth: 4 MHz to 80 MHz fREF = 19.44 MHz1; fDDS = 155.52 MHz2; fLOOP = 1 kHz3 0.71 0.34 0.43 0.43 0.31 ps rms ps rms ps rms ps rms ps rms 1.05 0.34 0.43 0.43 0.32 ps rms ps rms ps rms ps rms ps rms Bandwidth: 100 Hz to 77 MHz Bandwidth: 5 kHz to 20 MHz Bandwidth: 20 kHz to 80 MHz Bandwidth: 50 kHz to 80 MHz Bandwidth: 4 MHz to 80 MHz Rev. G | Page 12 of 111 Test Conditions/Comments fSYSCLK = 20 MHz4 OCXO; fS = 1 GHz5; Qdivider = 1; default SysClk PLL charge pump current; results valid for LVPECL, LVDS, and CMOS output logic types Random jitter Random jitter Random jitter Random jitter Random jitter fSYSCLK = 50 MHz4 crystal; fS = 1 GHz5; Q-divider = 1; default SYSCLK PLL charge pump current; results valid for LVPECL, LVDS, and CMOS output logic types Random jitter Random jitter Random jitter Random jitter Random jitter fSYSCLK = 50 MHz4 crystal; fS = 1 GHz5; Q-divider = 1; default SYSCLK PLL charge pump current; results valid for LVPECL, LVDS, and CMOS output logic types Random jitter Random jitter Random jitter Random jitter Random jitter Data Sheet Parameter fREF = 19.44 Hz1; fDDS = 311.04 MHz2; fLOOP = 1 kHz3 Bandwidth: 100 Hz to 100 MHz Bandwidth: 5 kHz to 20 MHz Bandwidth: 20 kHz to 80 MHz Bandwidth: 50 kHz to 80 MHz Bandwidth: 4 MHz to 80 MHz AD9548 Min Typ Max 0.67 0.31 0.33 0.33 0.16 fREF is the frequency of the active reference. fDDS is the output frequency of the DDS. 3 fLOOP is the DPLL digital loop filter bandwidth. 4 fSYSCLK is the frequency at the SYSCLKP and SYSCLKN pins. 5 fS is the sample rate of the output DAC. 1 2 Rev. G | Page 13 of 111 Unit ps rms ps rms ps rms ps rms ps rms Test Conditions/Comments fSYSCLK = 50 MHz4 crystal; fS = 1 GHz5; Q-divider = 1; default SYSCLK PLL charge pump current; results valid for LVPECL, LVDS, and CMOS output logic types Random jitter Random jitter Random jitter Random jitter Random jitter AD9548 Data Sheet ABSOLUTE MAXIMUM RATINGS Table 20. Parameter Analog Supply Voltage (AVDD) Digital Supply Voltage (DVDD) Digital I/O Supply Voltage (DVDD3) DAC Supply Voltage (AVDD3) Maximum Digital Input Voltage Storage Temperature Range Operating Temperature Range Lead Temperature (Soldering 10 sec) Junction Temperature Rating 2V 2V 3.6 V 3.6 V −0.5 V to DVDD3 + 0.5 V −65°C to +150°C −40°C to +85°C 300°C 150°C Stresses at or above those listed under Absolute Maximum Ratings may cause permanent damage to the product. This is a stress rating only; functional operation of the product at these or any other conditions above those indicated in the operational section of this specification is not implied. Operation beyond the maximum operating conditions for extended periods may affect product reliability. ESD CAUTION Rev. G | Page 14 of 111 Data Sheet AD9548 88 87 86 85 84 83 82 81 80 79 78 77 76 75 74 73 72 71 70 69 68 67 DVDD M7 M6 M5 M4 DVDD DVDD3 M3 M2 M1 M0 DVDD IRQ NC AVDD AVDD3 REFDD REFD AVDD REFCC REFC AVDD3 PIN CONFIGURATION AND FUNCTION DESCRIPTIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 AD9548 TOP VIEW (Not to Scale) 88-LEAD LFCSP 12mm × 12mm 0.5mm PITCH 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 AVDD3 REFBB REFB AVDD REFAA REFA AVDD3 AVDD TDC_VRT TDC_VRB NC AVDD VSS SYSCLKP SYSCLKN VSS AVDD SYSCLK_LF SYSCLK_VREG AVDD3 NC NC NOTES 1. NC = NO CONNECT. 2. THE EXPOSED PAD MUST BE CONNECTED TO GROUND (VSS). 08022-002 AVDD AVDD VSS CLKINN CLKINP VSS AVDD OUT_RSET AVDD3 OUT0P OUT0N AVDD OUT1P OUT1N AVDD3 AVDD3 OUT2P OUT2N AVDD OUT3P OUT3N AVDD3 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 DVDD SCLK/SCL SDIO SDO CS/SDA DVDD DVDD3 TCLK TMS TDO TDI DVDD RESET DVDD DVDD NC VSS DACOUTP DACOUTN VSS AVDD3 AVDD3 Figure 2. 88-Lead LFCSP Pin Configuration Table 21. Pin Function Descriptions Pin No. 1, 6, 12, 77, 83, 88 2 3 Mnemonic DVDD Input/ Output I Pin Type Power Description 1.8 V Digital Supply. SCLK/SCL SDIO I I/O 3.3 V CMOS 3.3 V CMOS 4 SDO O 3.3 V CMOS 5 CS/SDA I 3.3 V CMOS 7, 82 8 9 10 11 13 DVDD3 TCLK TMS TDO TDI RESET I I I O I I Power 14, 15 16, 45, 46 17, 20, 25, 28, 51, 54 18 DVDD NC VSS I Power O Ground Serial Programming Clock. Data clock for serial programming. Serial Data Input/Output. When the device is in 4-wire mode, data is written via this pin. In 3-wire mode, both data reads and writes occur on this pin. There is no internal pull-up/pull-down resistor on this pin. Serial Data Output. Use this pin to read data in 4-wire mode (high impedance in 3-wire mode). There is no internal pull-up/pull-down resistor on this pin. Chip Select (SPI). Active low. When programming a device, this pin must be held low. In systems where more than one AD9548 is present, this pin enables individual programming of each AD9548 (in I2C® mode, this is a serial data pin). This pin has an internal 10 kΩ pull-up resistor but only in SPI mode. 3.3 V I/O Digital Supply. JTAG Clock. Internal pull-down resistor; no connection if JTAG is not used. JTAG Mode. Internal pull-up resistor; no connection if JTAG is not used. JTAG Output. No connection if JTAG is not used. JTAG Input. Internal pull-up resistor; no connection if JTAG is not used. Chip Reset. When this active high pin is asserted, the chip goes into reset. This pin has an internal 50 kΩ pull-down resistor. 1.8 V DAC Decode Digital Supply. Group these pins with the other DVDD pins. No Connect. Analog Ground. Connect to ground. DACOUTP O 19 DACOUTN O Differential output Differential output 3.3 V CMOS DAC Output. DACOUTP contains an internal 50 Ω pull-down resistor. Complementary DAC Output. DACOUTN contains an internal 50 Ω pull-down resistor. Rev. G | Page 15 of 111 AD9548 Data Sheet Pin No. 21, 22 23, 24 26 Mnemonic AVDD3 AVDD CLKINN Input/ Output I I I 27 CLKINP I 29 30 AVDD OUT_RSET I O 31, 37, 38, 44 AVDD3 I 32 OUT0P O LVPECL, LVDS, or CMOS 33 OUT0N O 34, 41 35 AVDD OUT1P I O LVPECL, LVDS, or CMOS Power LVPECL, LVDS, or CMOS 36 OUT1N O 39 OUT2P O 40 OUT2N O 42 OUT3P O 43 OUT3N O 47 48 AVDD3 SYSCLK_VREG I I 49 SYSCLK_LF O 50, 55 AVDD I Pin Type Power Power Differential input Differential input Power Current set resistor Power LVPECL, LVDS, or CMOS LVPECL, LVDS, or CMOS LVPECL, LVDS, or CMOS LVPECL, LVDS, or CMOS LVPECL, LVDS, or CMOS Power Power Description 3.3 V Analog (DAC) Power Supply. 1.8 V Analog (DAC) Power Supply. Clock Distribution Input. In standard operating mode, this pin is connected to the filtered DACOUTN output. This internally biased input is typically ac-coupled and, when configured as such, can accept any differential signal whose single-ended swing is at least 400 mV. Clock Distribution Input. In standard operating mode, this pin is connected to the filtered DACOUTP output. 1.8 V Analog (Input Receiver) Power Supply. Connect an optional 3.12 kΩ resistor from this pin to ground (see the Output Current Control with an External Resistor section). Analog Supply for Output Driver. These pins are normally 3.3 V but can be 1.8 V. Pin 31 powers Out0x. Pin 37 powers OUT1x. Pin 38 powers OUT2x. Pin 44 powers OUT3x. Apply power to these pins even if the corresponding outputs (OUT0P/ OUT0N, OUT1P/ OUT1N, OUT2P/ OUT2N, and OUT3P/ OUT3N) are not used. See the Power Supply Partitions section. Output 0. This output can be configured as LVPECL, LVDS, or single-ended CMOS. LVPECL and LVDS operation require a 3.3 V output driver power supply. CMOS operation can be either 1.8 V or 3.3 V, depending on the output driver power supply. Complementary Output 0. This output can be configured as LVPECL, LVDS, or single-ended CMOS. 1.8 V Analog (Output Divider) Power Supply. Output 1. This output can be configured as LVPECL, LVDS, or single-ended CMOS. LVPECL and LVDS operation require a 3.3 V output driver power supply. CMOS operation can be either 1.8 V or 3.3 V, depending on the output driver power supply. Complementary Output 1. This output can be configured as LVPECL, LVDS, or single-ended CMOS. Output 2. This output can be configured as LVPECL, LVDS, or single-ended CMOS. LVPECL and LVDS operation require a 3.3 V output driver power supply. CMOS operation can be either 1.8 V or 3.3 V, depending on the output driver power supply. Complementary Output 2. This output can be configured as LVPECL, LVDS, or single-ended CMOS. Output 3. This output can be configured as LVPECL, LVDS, or single-ended CMOS. LVPECL and LVDS operation require a 3.3 V output driver power supply. CMOS operation can be either 1.8 V or 3.3 V, depending on the output driver power supply. Complementary Output 3. This output can be configured as LVPECL, LVDS, or single-ended CMOS. 3.3 V Analog (System Clock) Power Supply. System Clock Loop Filter Voltage Regulator. Connect a 0.1 μF capacitor from this pin to ground. This pin is also the ac ground reference for the integrated SYSCLK PLL multiplier’s external loop filter (see the SYSCLK PLL Multiplier section). System Clock Multiplier Loop Filter. When using the frequency multiplier to drive the system clock, an external loop filter can be attached to this pin. 1.8 V Analog (System Clock) Power Supply. Rev. G | Page 16 of 111 Data Sheet AD9548 Pin No. 52 Mnemonic SYSCLKN Input/ Output I 53 SYSCLKP I 56, 75 59 57, 58 NC AVDD TDC_VRB, TDC_VRT AVDD3 I I I Power I Power 3.3 V Analog (Reference Input) Power Supply. REFA I Differential input 62 REFAA I 63, 70, 74 64 AVDD REFB I I Differential input Power Differential input 65 REFBB I 68 REFC I 69 REFCC I 71 REFD I 72 REFDD I 76 78, 79, 80, 81, 84, 85, 86, 87 IRQ M0, M1, M2, M3, M4, M5, M6, M7 O I/O EP VSS O Reference A Input. This internally biased input is typically ac-coupled and, when configured as such, can accept any differential signal with single-ended swing up to 3.3 V. If dc-coupled, input can be LVPECL, CMOS, or LVDS. Complementary Reference A Input. Complementary signal to the input provided on Pin 61. The user can configure this pin as a separate single-ended input. 1.8 V Analog (Reference Input) Power Supply. Reference B Input. This internally biased input is typically ac-coupled and, when configured as such, can accept any differential signal with single-ended swing up to 3.3 V. If dc-coupled, input can be LVPECL, CMOS, or LVDS. Complementary Reference B Input. Complementary signal to the input provided on Pin 64. The user can configure this pin as a separate single-ended input. Reference C Input. This internally biased input is typically ac-coupled and, when configured as such, can accept any differential signal with single-ended swing up to 3.3 V. If dc-coupled, input can be LVPECL, CMOS, or LVDS. Complementary Reference C Input. Complementary signal to the input provided on Pin 68. The user can configure this pin as a separate single-ended input. Reference D Input. This internally biased input is typically ac-coupled and, when configured as such, can accept any differential signal with single-ended swing up to 3.3 V. If dc-coupled, input can be LVPECL, CMOS, or LVDS. Complementary Reference D Input. Complementary signal to the input provided on Pin 71. The user can configure this pin as a separate single-ended input. Interrupt Request Line. Configurable I/O Pins. These pins are configured under program control. M0 to M2 control the serial port mode selection (see Table 29), and M3 to M7 control the EEPROM loading at startup or reset (see the Initial M0 to M7 Pin Programming section). Note that there are no internal pull-up or pull-down resistors on these pins, and the user should place pull-up or pull-down resistors on each of these pins to avoid unpredictable start-up behavior. The exposed pad must be connected to ground (VSS). 60, 66, 67, 73 61 Pin Type Differential input Differential input Differential input Differential input Differential input Differential input Differential input Logic 3.3 V CMOS Exposed pad Description Complementary System Clock Input. Complementary signal to SYSCLKP. SYSCLKN contains internal dc biasing and should be ac-coupled with a 0.01 μF capacitor, except when using a crystal. When using a crystal, connect the crystal across SYSCLKP and SYSCLKN. When using a crystal, the user should consider placing a 0 Ω series resistor on the SYSCLKN pin. In the event that the power dissipated in the crystal must be reduced, the user can replace the 0 Ω resistor with a larger resistor (for example, 500 Ω. However, this series resistor is rarely needed. (See Figure 34). System Clock Input. SYSCLKP contains internal dc biasing and should be accoupled with a 0.01 μF capacitor, except when using a crystal, in which case connect the crystal across SYSCLKP and SYSCLKN. Single-ended 1.8 V CMOS is also an option but can introduce a spur if the doubler is enabled and the duty cycle is not 50%. When using SYSCLKP as a single-ended input, connect a 0.01 μF capacitor from SYSCLKN to ground. No Connection. These pins should be left floating. 1.8 V Analog Power Supply. Use capacitive decoupling on these pins (see Figure 40). Rev. G | Page 17 of 111 AD9548 Data Sheet TYPICAL PERFORMANCE CHARACTERISTICS fR = input reference clock frequency; fO = clock frequency; fSYS = SYSCLK input frequency; fS = internal system clock frequency; LBW = DPLL loop bandwidth; PLL off = SYSCLK PLL bypassed; PLL on = SYSCLK PLL enabled; ICP = SYSCLK PLL charge pump current; LF = SYSCLK PLL loop filter. AVDD, AVDD3, and DVDD at nominal supply voltage, fS = 1 GHz, ICP = automatic mode, LF = internal, unless otherwise noted. –70 –70 INTEGRATED RMS JITTER (PHASE NOISE): 5kHz TO 20MHz: 173fs (–75.4dBc) 20kHz TO 80MHz: 315fs (–70.2dBc) (EXTRAPOLATED) –80 –100 –110 –120 –130 –100 –110 –120 –130 –140 –140 –150 –150 –160 100 1k 10k 100k 1M 10M 100M FREQUENCY OFFSET (Hz) –160 100 100k 1M 10M 100M Figure 5. Additive Phase Noise (Output Driver = LVPECL), fR = 19.44 MHz, fO = 311.04 MHz, LBW = 1 kHz, fSYS = 1 GHz, PLL Off –70 INTEGRATED RMS JITTER (PHASE NOISE): 5kHz TO 20MHz: 333fs (–69.8dBc) 20kHz TO 80MHz: 430fs (–67.6dBc) (EXTRAPOLATED) –80 10k FREQUENCY OFFSET (Hz) Figure 3. Additive Phase Noise (Output Driver = LVPECL), fR = 19.44 MHz, fO = 155.52 MHz, LBW = 1 kHz, fSYS = 1 GHz, PLL Off –70 1k 08022-066 PHASE NOISE (dBc/Hz) –90 08022-068 INTEGRATED RMS JITTER (PHASE NOISE): 5kHz TO 20MHz: 310fs (–64.4dBc) 20kHz TO 80MHz: 330fs (–63.9dBc) –80 –90 PHASE NOISE (dBc/Hz) –90 –100 –110 –120 –130 –100 –110 –120 –130 –140 –150 –150 –160 100 1k 10k 100k 1M 10M 100M FREQUENCY OFFSET (Hz) 08022-056 –140 –160 100 1k 10k 100k 1M 10M 100M FREQUENCY OFFSET (Hz) Figure 6. Additive Phase Noise (Output Driver = LVPECL), fR = 19.44 MHz, fO = 311.04 MHz, LBW = 1 kHz, fSYS = 50 MHz (Crystal), PLL On Figure 4. Additive Phase Noise (Output Driver = LVPECL), fR = 19.44 MHz, fO = 155.52 MHz, LBW = 1 kHz, fSYS = 50 MHz (Crystal), PLL On Rev. G | Page 18 of 111 08022-067 PHASE NOISE (dBc/Hz) –90 PHASE NOISE (dBc/Hz) INTEGRATED RMS JITTER (PHASE NOISE): 5kHz TO 20MHz: 103fs (–74.0dBc) 20kHz TO 80MHz: 160fs (–70.1dBc) –80 Data Sheet –70 INTEGRATED RMS JITTER (PHASE NOISE): 5kHz TO 20MHz: 361fs (–69.0dBc) 20kHz TO 80MHz: 441fs (–67.3dBc) (EXTRAPOLATED) –80 –80 PHASE NOISE (dBc/Hz) –100 –110 –120 –130 –120 –130 –150 –150 –160 100 –160 100 10k 1k 100k 10M 1M 100M –70 –90 ROHDE & SCHWARZ SMA100 (1GHz) 1k 10k 100k 1M 10M 100M FREQUENCY (Hz) Figure 10. Absolute Phase Noise Comparison of SYSCLK Input Options (Output Driver = LVPECL), fR = 19.44 MHz, fO = 311.04 MHz, LBW = 1 kHz –70 INTEGRATED RMS JITTER (PHASE NOISE): 5kHz TO 10MHz: 717fs (–65.1dBc) 12kHz TO 20MHz: 725fs (–65.0dBc) 20kHz TO 80MHz: 790fs (–64.3dBc) –80 ROHDE & SCHWARZ SMA100 (50MHz) –110 –140 Figure 7. Absolute Phase Noise (Output Driver = LVPECL), fR = 19.44 MHz, fO = 155.52 MHz, LBW = 1 kHz, fSYS = 50 MHz, PLL On –80 INTEGRATED RMS JITTER (PHASE NOISE): 5kHz TO 20MHz: 356fs (–69.2dBc) 20kHz TO 80MHz: 435fs (–67.4dBc) (EXTRAPOLATED) –100 –110 –120 –130 –100 –110 –120 –130 –140 –140 –150 –150 –160 10 100 10k 1k 100k 1M 10M 100M FREQUENCY OFFSET (Hz) –160 100 100k 1M 10M 100M Figure 11. Absolute Phase Noise (Output Driver = LVPECL), fR = 1 Hz, fO = 155.52 MHz, LBW = 0.05 Hz, fSYS = 50 MHz, PLL On –70 INTEGRATED RMS JITTER (PHASE NOISE): 5kHz TO 20MHz: 336fs (–69.7dBc) 20kHz TO 80MHz: 425fs (–67.6dBc) (EXTRAPOLATED) –80 10k FREQUENCY OFFSET (Hz) Figure 8. Absolute Phase Noise (Output Driver = LVPECL), fR = 1 Hz, fO = 122.88 MHz, LBW = 0.05 Hz, fSYS = 20 MHz (OCXO), PLL On –70 1k 08022-054 PHASE NOISE (dBc/Hz) –90 08022-044 –80 –90 INTEGRATED RMS JITTER (PHASE NOISE): 5kHz TO 20MHz: 245fs (–72.4dBc) 20kHz TO 80MHz: 300fs (–64.3dBc) (EXTRAPOLATED) PHASE NOISE (dBc/Hz) –90 –100 –110 –120 –130 –100 –110 –120 –130 –140 –150 –150 –160 100 1k 10k 100k 1M 10M 100M FREQUENCY OFFSET (Hz) 08022-052 –140 Figure 9. Absolute Phase Noise (Output Driver = LVPECL), fR = 8 kHz, fO = 155.52 MHz, LBW = 100 Hz, fSYS = 50 MHz (Crystal), PLL On –160 100 1k 10k 100k 1M 10M 100M FREQUENCY OFFSET (Hz) Figure 12. Absolute Phase Noise (Output Driver = LVPECL), fR = 19.44 MHz, fO = 155.52 MHz, LBW = 1 kHz, fSYS = 50 MHz (Crystal), PLL On with 2x Frequency Multiplier, ICP = 375 μA, LF = External (350 kHz) Rev. G | Page 19 of 111 08022-051 PHASE NOISE (dBc/Hz) –100 –140 FREQUENCY OFFSET (Hz) PHASE NOISE (dBc/Hz) 50MHz CRYSTAL –90 08022-069 PHASE NOISE (dBc/Hz) –90 08022-058 –70 AD9548 Data Sheet 10 –100 0 –110 –10 CLOSED-LOOP GAIN (dB) –90 –120 ROHDE & SCHWARZ SMA100 (1GHz) –140 20MHz OCXO –150 –160 1k 10k 100k –20 –30 –40 –50 –60 ROHDE & SCHWARZ SMA100 (50MHz) –170 100 CLOSED-LOOP PEAKING: 0.04dB 1M 10M FREQUENCY OFFSET (Hz) –70 10 100 1k 10k Figure 16. Jitter Transfer Bandwidth, Output Driver = LVPECL, fR = 19.44 MHz, fO = 155.52 MHz, LBW = 100 Hz (Phase Margin = 88°), fSYS = 1 GHz, PLL Off Figure 13. Phase Noise of SYSCLK Input Sources 2.0 1.0 5pF LOAD 0.8 AMPLITUDE (V) 0.4 LVDS 1.5 20pF LOAD 1.0 100 200 300 500 400 600 700 FREQUENCY (MHz) 0.5 08022-049 0 0 150 200 250 Figure 17. Amplitude vs. Toggle Rate, 1.8 V CMOS 4.0 4.0 3.5 3.5 10pF LOAD 5pF LOAD AMPLITUDE (V) 3.0 2.5 20pF LOAD 2.0 1.5 3.0 10pF LOAD 2.5 2.0 1.5 0 100 200 300 400 FREQUENCY (MHz) 500 08022-055 AMPLITUDE (V) 100 FREQUENCY (MHz) Figure 14. Amplitude vs. Toggle Rate, LVPECL and LVDS 1.0 50 08022-062 10pF LOAD 0.2 1.0 0 10 20 30 40 FREQUENCY (MHz) Figure 18. Amplitude vs. Toggle Rate, 3.3 V CMOS (Weak Mode) Figure 15. Amplitude vs. Toggle Rate, 3.3 V CMOS (Strong Mode) Rev. G | Page 20 of 111 50 08022-063 AMPLITUDE (V) LVPECL 0.6 0 100k FREQUENCY OFFSET (Hz) 08022-047 –130 08022-053 PHASE NOISE (dBc/Hz) AD9548 Data Sheet AD9548 40 140 130 LVPECL 10pF LOAD POWER (mW) 110 POWER (mW) 20pF LOAD 35 120 100 90 80 5pF LOAD 30 25 LVDS 70 20 200 300 400 500 FREQUENCY (MHz) 15 0 Figure 22. Power Consumption vs. Frequency, 1.8 V CMOS 160 34 140 32 30 POWER (mW) 20pF LOAD 5pF LOAD 80 40 22 0 50 100 150 200 250 300 350 FREQUENCY (MHz) 20pF LOAD 20 10 25 20 30 35 40 5 Figure 23. Power Consumption vs. Frequency, 3.3 V CMOS (Weak Mode) 0.5 0.8 0.4 0.6 0.3 DIFFERENTIAL AMPLITUDE (V) 1.0 0.4 0.2 0 –0.2 –0.4 –0.6 0.2 0.1 0 –0.1 –0.2 –0.3 –0.4 –0.8 0 1 2 3 TIME (ns) 4 5 08022-050 DIFFERENTIAL AMPLITUDE (V) 15 FREQUENCY (MHz) Figure 20. Power Consumption vs. Frequency, 3.3 V CMOS (Strong Mode) –1.0 5pF LOAD 26 24 20 10pF LOAD 28 60 08022-060 POWER (mW) 120 10pF LOAD 200 FREQUENCY (MHz) Figure 19. Power Consumption vs. Frequency, LVPECL and LVDS (Single Channel) 100 150 100 50 08022-059 100 08022-048 0 08022-064 50 08022-061 60 –0.5 0 1 2 3 TIME (ns) Figure 24. Output Waveform, LVDS (400 MHz) Figure 21. Output Waveform, LVPECL (400 MHz) Rev. G | Page 21 of 111 4 AD9548 Data Sheet 3.5 3.5 10pF LOAD 20pF LOAD AMPLITUDE (V) 2.5 2.0 1.5 1.0 1.0 0 0 0 2 4 6 8 12 10 14 16 TIME (ns) 2.0 10pF LOAD 1.5 20pF LOAD 1.0 0.5 2 4 6 8 10 TIME (ns) 12 14 16 08022-065 0 0 –0.5 0 10 20 30 40 50 60 TIME (ns) Figure 27. Output Waveform, 3.3 V CMOS (20 MHz, Weak Mode) Figure 25. Output Waveform, 3.3 V CMOS (100 MHz, Strong Mode) –0.5 20 pF LOAD 1.5 0.5 –0.5 AMPLITUDE (V) 2.0 0.5 08022-057 AMPLITUDE (V) 2.5 5pF LOAD 3.0 Figure 26. Output Waveform, 1.8 V CMOS (100 MHz) Rev. G | Page 22 of 111 70 80 08022-046 3.0 Data Sheet AD9548 INPUT/OUTPUT TERMINATION RECOMMENDATIONS 0.1µF DOWNSTREAM DEVICE 100Ω 100Ω HIGH IMPEDANCE INPUT 0.1µF AD9548 SELF-BIASED CLKINx INPUT 08022-007 08022-003 0.1µF (OPTIONAL) AD9548 3.3V LVDS OUTPUT 0.1µF Figure 28. AC-Coupled LVDS or LVPECL Output Driver Figure 32. CLKINx Input 3.3V CMOS TCXO AD9548 100Ω DOWNSTREAM DEVICE 3.3V LVPECLCOMPATIBLE OUTPUT 0.1µF 300Ω SYSCLKP 150Ω AD9548 08022-004 SYSCLKN Figure 29. DC-Coupled LVDS or LVPECL Output Driver 08022-134 0.1µF Figure 33. System Clock Input (SYSCLKP/SYSCLKN) When Using a TCXO/OCXO with 3.3 V CMOS Output 15pF 0.1µF 10MHz TO 50MHz FUNDAMENTAL AT-CUT CRYSTAL WITH 10pF LOAD CAPACITANCE (C LOAD) AD9548 Figure 34. System Clock Input (XOA/XOB) in Crystal Mode SELF-BIASED SYSCLK INPUT 08022-006 (OPTIONAL) 0.1µF 100Ω SYSCLKN NOTES 1. THE RECOMMENDED CLOAD = 10pF IS SHOWN. THE VALUES OF THE 15pF SHUNT CAPACITORS SHOWN HERE MUST EQUAL 2 × (CLOAD − CSTRAY ), WHERE CSTRAY IS TYPICALLY 2pF TO 5pF). THE SERIES RESISTOR CONNECTED TO SYSCLKN IS NORMALLY NOT REQUIRED, BUT CAN BE USEFUL TO LIMIT THE POWER DISSIPATED IN THE CRYSTAL. Figure 30. Reference Input 0.1µF 0Ω 15pF (OPTIONAL) AD9548 Figure 31. SYSCLKx Input Rev. G | Page 23 of 111 08022-133 AD9548 SELF-BIASED REFERENCE INPUT 08022-005 0.1µF (OPTIONAL) 100Ω SYSCLKP AD9548 Data Sheet GETTING STARTED POWER-ON RESET The AD9548 monitors the voltage on the power supplies at power-up. When DVDD3 is greater than 2.35 V ± 0.1 V and DVDD (Pin 1, Pin 6, Pin 12, Pin 77, Pin 83, and Pin 88) is greater than 1.4 V ± 0.05 V, the device generates a 75 ns reset pulse. The power-up reset pulse is internal and independent of the RESET pin. This internal power-up reset sequence eliminates the need for the user to provide external power supply sequencing. Within 45 ns after the leading edge of the internal reset pulse, the M0 to M7 multifunction pins behave as high impedance digital inputs and remain so until programmed otherwise. It is essential to program the system clock period because many of the AD9548 subsystems rely on this value. It is highly recommended to program the system clock stability timer, as well. This is especially important when using the system clock PLL but also applies if using an external system clock source, especially if the external source is not expected to be completely stable when power is applied to the AD9548. Initialize the System Clock After the system clock functionality is programmed, issue an input/output update using Register 0x0005, Bit 0 to invoke the system clock settings. INITIAL M0 TO M7 PIN PROGRAMMING Calibrate the System Clock (Only if Using SYSCLK PLL) During a device reset (either via the power-up reset pulse or the RESET pin), the multifunction pins (M0 to M7) behave as high impedance inputs, but upon removal of the reset condition, level-sensitive latches capture the logic pattern present on the multifunction pins. The AD9548 requires that the user supply the desired logic state to the M0 to M7 pins by means of pull-up and/or pull-down resistors (nominally 10 kΩ to 30 kΩ). Set the calibrate system clock bit in the sync/cal register (Address 0x0A02, Bit 0) and issue an input/output update. Then clear the calibrate system clock bit and issue another input/output update. This action allows time for the calibration to proceed while programming the remaining device registers. The initial state of the M0 to M7 pins following a reset is referred to as FncInit, Bits[7:0]. Bits[7:0] of FncInit map directly to the logic states of M7:0, respectively. The three LSBs of FncInit (FncInit, Bits[2:0]) determine whether the serial port interface behaves according to the SPI or I2C protocol. Specifically, FncInit, Bits[2:0] = 000 selects the SPI interface, while any other value selects the I2C port with the three LSBs of the I2C bus address set to the value of FncInit, Bits[2:0]. The five MSBs of FncInit (FncInit, Bits[7:3]) determine the operation of the EEPROM loader. On the falling edge of RESET, if FncInit, Bits[7:3] = 00000, then the EEPROM contents are not transferred to the control registers and the device registers assume their default values. However, if FncInit, Bits[7:3] ≠ 00000, then the EEPROM controller transfers the contents of the EEPROM to the control registers with condition = FncInit, Bits[7:3] (see the EEPROM section). DEVICE REGISTER PROGRAMMING The initial state of the M0 to M7 pins establishes the serial input/output port protocol (SPI or I2C). Using the appropriate serial port protocol, and assuming that an EEPROM download is not used, program the device according to the recommended sequence described in the Program the System Clock Functionality section through the Generate the Output Clock section. Program the Multifunction Pins (Optional) This step is required only if the user intends to use any of the multifunction pins for status or control. The multifunction pin parameters reside in the 0x0200 to 0x0207 register address space. The default configuration of the multifunction pins is as an undesignated high impedance input pin. Program the IRQ Functionality (Optional) This step is required only if the user intends to use the IRQ feature. IRQ control resides in the 0x0200 to 0x0207 register address space. It includes the following: The IRQ mask default values prevent interrupts from being generated. The IRQ pin mode default is open-drain NMOS. Program the Watchdog Timer (Optional) This step is required only if the user intends to use it. Watchdog timer control resides in the 0x0200 register address space. The watchdog timer is disabled by default. Program the DAC Full-Scale Current (Optional) This step is required only if the user intends to use a full-scale current setting other than the default value. DAC full-scale current control resides in the 0x0200 register address space. Program the System Clock Functionality The system clock parameters reside in the 0100 register address space. They include the following: IRQ pin mode control IRQ mask System clock PLL controls System clock period System clock stability timer Rev. G | Page 24 of 111 Data Sheet AD9548 Program the Digital Phase-Locked Loop (DPLL) Generate the Reference Acquisition The DPLL parameters reside in the 0x0300 register address space. They include the following: After the registers are programmed, issue an input/output update using Register 0x0005, Bit 0 to invoke all of the register settings programmed up to this point. Free-run frequency (DDS frequency tuning word) DDS phase offset DPLL pull-in range limits DPLL closed-loop phase offset Phase slew control (for hitless reference switching) Tuning word history control (for holdover operation) Program the Clock Distribution Outputs The clock distribution parameters reside in the 0x0400 register address space. They include the following: Output power-down control Output enable (disabled by default) Output synchronization Output mode control Output divider functionality Generate the Output Clock Program the Reference Inputs The reference input parameters reside in the 0x0500 register address space. They include the following: If the settings are programmed for manual profile assignment, the DPLL locks to the first available reference that has the highest priority. If the settings are programmed for automatic profile assignment, then write to the reference profile detect register (Address 0x0A0D) to select the state machines that require starting. Next, issue an input/output update (Address 0x0005, Bit 0) to start the selected state machines. Upon completion of the reference detection sequence, the DPLL locks to the first available reference with the highest priority. Reference power-down Reference logic family Reference profile assignment control Phase build-out control If the registers are programmed for automatic clock distribution synchronization via DPLL phase or frequency lock, the synthesized output signal appears at the clock distribution outputs (assuming the output is enabled and that the DDS output signal has been routed to the CLKIN input pins). Otherwise, set and then clear the sync distribution bit (Address 0x0A02, Bit 1) or use a multifunction pin input (if programmed accordingly) to generate a clock distribution sync pulse, which causes the synthesized output signal to appear at the clock distribution outputs. Program the Reference Profiles The reference profile parameters reside in the 0x0600 to 0x0700 register address space. They include the following: Reference priority Reference period Reference period tolerance Reference validation timer Reference redetect timer Digital loop-filter coefficients Reference prescaler (R-divider) Feedback dividers (S, U, and V) Phase and frequency lock detector controls Rev. G | Page 25 of 111 AD9548 Data Sheet THEORY OF OPERATION OUT_RSET AD9548 REFA REFAA DIFFERENTIAL OR SINGLE-ENDED REFB REFBB REFC REFCC DIGITAL PLL CORE ÷S REFD REFDD TDC/PFD ÷R PROG. DIGITAL LOOP FILTER POST DIV OUT1P OUT1N POST DIV OUT2P OUT2N POST DIV OUT3P OUT3N TW CLAMP AND HISTORY DDS/DAC EXTERNAL ANALOG FILTER INPUT REF MONITOR IRQ AND STATUS LOGIC CLKINN CLOCK DISTRIBUTION HOLDOVER LOGIC PHASE CONTROLLER IRQ OUT0P OUT0N CLKINP 4 OR 8 M0 TO M7 POST DIV LOW NOISE CLOCK MULTIPLIER CONTROL LOGIC AMP SYSCLKN SYSCLKP DIGITAL INTERFACE 08022-009 SYSCLK PORT Figure 35. Detailed Block Diagram OVERVIEW The AD9548 provides clocking outputs directly related in phase and frequency to the selected (active) reference but with jitter characteristics primarily governed by the system clock. The AD9548 supports up to eight reference inputs and a wide range of reference frequencies. The core of this product is a digital phase-locked loop (DPLL). The DPLL has a programmable digital loop filter that greatly reduces jitter transferred from the active reference to the output. The AD9548 supports both manual and automatic holdover. While in holdover, the AD9548 continues to provide an output as long as the DAC sample clock is present. The holdover output frequency is a time average of the output frequency history just prior to the transition to the holdover condition. The device offers manual and automatic reference switchover capability if the active reference is degraded or fails completely. A direct digital synthesizer (DDS) and integrated DAC constitute a digitally controlled oscillator (DCO). The DCO output is a sinusoidal signal (450 MHz maximum) at a frequency determined by the active reference frequency and the programmed values of the reference prescaler (R) and feedback divider (S). Although not explicitly shown in Figure 35, the S-divider has both an integer and fractional component, which is similar to a fractional-N synthesizer. The SYSCLKx input provides the sample clock for the DAC, which is either a directly applied high frequency source or a low frequency source coupled with the integrated PLL-based frequency multiplier. The low frequency option also allows for the use of a crystal resonator connected directly across the SYSCLKx inputs. The DAC output routes directly off-chip, where an external filter removes the sampling artifacts before returning the signal on-chip at the CLKINx inputs. Once on-chip, an integrated comparator converts the filtered sinusoidal signal to a clock signal (square wave) with very fast rise and fall times. The clock distribution section provides four output drivers. Each driver is programmable either as a single differential LVPECL/LVDS output or as a dual single-ended CMOS output. Furthermore, each of the four outputs has a dedicated 30-bit programmable postdivider. The clock distribution section operates at up to 725 MHz. This enables use of a band-pass reconstruction filter (for example, a SAW filter) to extract a Nyquist image from the DAC output spectrum, thereby allowing output frequencies that exceed the typical 450 MHz limit at the DAC output. Rev. G | Page 26 of 111 Data Sheet AD9548 REFERENCE CLOCK INPUTS Four pairs of pins provide access to the reference clock receivers. Each pair is configurable either as a single differential receiver or as two independent single-ended receivers. To accommodate input signals with slow rising and falling edges, both the differential and single-ended input receivers employ hysteresis. Hysteresis also ensures that a disconnected or floating input does not cause the receiver to oscillate spontaneously. When configured for differential operation, the input receivers accommodate either ac- or dc-coupled input signals. The receiver is internally dc biased in order to handle ac-coupled operation. When configured for single-ended operation, the input receivers exhibit a pull-down load of 45 kΩ (typical). Three user programmable threshold voltage ranges are available for each single-ended receiver. REFERENCE MONITORS The reference monitors depend on a known and accurate system clock period. Therefore, the functioning of the reference monitors is not reliable until the system clock is stable. To avoid an incorrect valid indication, the reference monitors indicate fault status until the system clock stability timer expires (see the System Clock Stability Timer section). Reference Period Monitor Each reference input has a dedicated monitor that repeatedly measures the reference period. The AD9548 uses the reference period measurements to determine the validity of the reference based on a set of user provided parameters in the profile register area of the register map (see the Profile Registers (Register 0X0600 to Register 0X07FF) section). The AD9548 also uses the reference period monitor to assign a particular reference to a profile when the user programs the device for automatic profile assignment. The monitor works by comparing the measured period of a particular reference input with the parameters stored in the profile register assigned to that same reference input. The parameters include the reference period, an inner tolerance, and an outer tolerance. A 50-bit number defines the reference period in units of femtoseconds. The 50-bit range allows for a reference period entry of up to 1.125 sec. However, an actual reference signal with a period in excess of 1 sec is beyond the recommended operating range of the device. A 20-bit number defines the inner and outer tolerances. The value stored in the register is the reciprocal of the tolerance specification. For example, a tolerance specification of 50 ppm yields a register value of 1/(50 ppm) = 1/0.000050 = 20,000 (0x04E20). The use of two tolerance values provides hysteresis for the monitor decision logic. The inner tolerance applies to a previously faulted reference and specifies the largest period tolerance that a previously faulted reference can exhibit before it qualifies as nonfaulted. The outer tolerance applies to an already nonfaulted reference. It specifies the largest period tolerance that a nonfaulted reference can exhibit before being faulted. To produce decision hysteresis, the inner tolerance must be less than the outer tolerance. That is, a faulted reference must meet tighter requirements to become nonfaulted than a nonfaulted reference must meet to become faulted. Reference Validation Timer Each reference input has a dedicated validation timer. The validation timer establishes the amount of time that a previously faulted reference must remain fault free before the AD9548 declares it nonfaulted. The timeout period of the validation timer is programmable via a 16-bit register (see the validation register contained within each of the eight profile registers in the register map, Address 0x0600 to Address 0x07FF). The 16-bit number stored in the validation register represents units of milliseconds, which yields a maximum timeout period of 65,535 ms. Note that a validation period of 0 must be programmed to disable the validation timer. With the validation timer disabled, the user must validate a reference manually via the force validation timeout register (Address 0x0A0E). Reference Redetect Timer Each reference input has a dedicated redetect timer. The redetect timer is useful only with the device programmed for automatic profile selection. The redetect timer establishes the amount of time that a reference must remain faulted before the AD9548 attempts to reassign it to a new profile. The timeout period of the redetect timer is programmable via a 16-bit register (see the redetect timeout register contained within each of the eight profile registers in the register map, Address 0x0600 to Address 0x07FF). The 16-bit number stored in the redetect timeout register represents units of milliseconds, which yields a maximum timeout period of 65,535 ms. Note that a timeout period of 0 must be programmed to disable the redetect timer. Reference Validation Override Control Register 0x0A0E to Register 0x0A10 provide the user with the ability to override the reference validation logic enabling a certain level of troubleshooting capability. Each of the eight input references has a dedicated block of validation logic as shown in Figure 36. The state of the valid signal at the output is what defines a particular reference as valid (1) or not (0), which includes the validation period (if activated) as prescribed by the validation timer. The override controls are the three control bits on the left side of the diagram. Rev. G | Page 27 of 111 AD9548 Data Sheet REGISTER CONTROL BITS REFERENCE VALIDATION LOGIC (8 COPIES, 1 PER REFERENCE INPUT) FORCE VALIDATION TIMEOUT VALIDATION TIMER REF MONITOR BYPASS REF MONITOR OVERRIDE D Q R 1 EN VALID R TIMEOUT FAULTED 0 REF FAULT 08022-010 REFERENCE MONITOR Figure 36. Reference Validation Override The main feature to note is that any time faulted = 1, the output latch is reset, which forces valid = 0 (indicating an invalid reference) regardless of the state of any other signal. Under the default condition (that is, all three control bits are 0), the reference monitor is the primary source of the validation process. This is because, under the default condition, the ref fault signal from the reference monitor is identically equal to the faulted signal. The function of the faulted signal is fourfold. • • • • Any time faulted = 1, then valid = 0, regardless of the state of any other control signal. Therefore, faulted = 1 indicates an invalid reference. Any time the faulted signal transitions from 0 to 1 (that is, from nonfaulted to faulted), the validation timer is momentarily reset, which means that, when it is enabled, it must exhaust its full counting sequence before it expires. When faulted = 0 (that is, the reference is not faulted), the validation timer is allowed to perform its timing sequence. When faulted = 1 (that is, the reference is faulted), the validation timer is reset and halted. The faulted signal passes through an inverter, converting it to a nonfaulted signal, which appears at the input of the valid latch. This allows the valid latch to capture the state of the nonfaulted signal when the validation timer expires. The ref monitor bypass control bit enables bypassing of the ref fault signal generated by the reference monitor. When ref monitor bypass = 1, the state of the faulted signal is dictated by the ref monitor override control bit. This is useful when the user relies on an external reference monitor rather than the internal monitor resident in the device. The user programs the ref monitor override bit based on the status of the external monitor. On the other hand, when ref monitor bypass = 0, the ref monitor override control bit allows the user to manually test the operation of both the valid latch and the validation timer. In this case, the user relies on the signal generated by the internal reference monitor (ref fault) but uses the ref monitor override bit to emulate a faulted reference. That is, when ref monitor override = 1, then faulted = 1, but when ref monitor override = 0, then faulted = ref fault. In addition, the user has the ability to emulate a timeout of the validation timer via the appropriate force validation timeout control bit in Register 0x0A0E. Writing a Logic 1 to any of these autoclearing bits triggers the valid latch, which is identically equivalent to a timeout of the validation timer. REFERENCE PROFILES The AD9548 has eight independent profile registers. A profile register contains 50 bytes that establish a particular set of device parameters. Each of the eight input references can be assigned to any one of the eight profiles (that is, more than one reference can be assigned to the same profile). The profiles allow the user to prescribe the specific device functionality that should take effect when one of the input references (assigned to the profile) becomes the active reference. Each profile register has the same format and stores the following device parameters: • • • • • • • • • • • • • • • Reference priority Reference period value (in femtoseconds) Inner tolerance value (1/tolerance) Outer tolerance value (1/tolerance) Validation timer value (milliseconds) Redetect timer value (milliseconds) Digital loop filter coefficients Reference prescaler setting (R-divider) Feedback divider settings (S, U, and V) DPLL phase lock detector threshold level DPLL phase lock detector fill rate DPLL phase lock detector drain rate DPLL frequency lock detector threshold level DPLL frequency lock detector fill rate DPLL frequency lock detector drain rate Reference-to-Profile Assignment Control The user can manually assign a reference to a profile or let the device make the assignment automatically. The manual reference profile selection register (Address 0x0503 to Address 0x0506) is where the user programs whether a reference-to-profile assignment is manual or automatic. The manual reference profile selection register is a 4-byte register partitioned into eight half bytes (or nibbles). The eight nibbles form a one-to-one correspondence with the eight reference inputs: one nibble for REF A, the next for REF AA, and so on. For a reference configured as a differential input, however, the device ignores the nibble associated with the two-letter input. For example, if the B Rev. G | Page 28 of 111 Data Sheet AD9548 reference is differential, then only the REFB nibble matters (the device ignores the REFBB nibble). The MSB of each nibble is the manual profile bit, whereas the three LSBs of each nibble identify one of the eight profiles (0 to 7). A Logic 1 for the manual profile bit assigns the associated reference to the profile identified by the three LSBs of the nibble. A Logic 0 for the manual profile bit configures the associated reference for automatic reference-to-profile assignment (the three LSBs are ignored in this case). Note that references configured for automatic reference-to-profile assignment require activation (see the Reference-to-Profile Assignment State Machine section). Reference-to-Profile Assignment State Machine The functional flexibility of the AD9548 resides in the way that it assigns a particular input reference to one of the eight reference profiles. The reference-to-profile assignment state machine effectively builds a reference-to-profile table that maps the index of each input reference to a profile (see Table 22). Each entry in the profile column consists of a profile number (0 to 7) or a null value. A null value appears when a reference-to-profile assignment does not exist for a particular reference input (following a reset, for example). The information in Table 22 appears in the register map (Register 0x0D0C to Register 0x0D13) so that the user has access to the reference-to-profile assignments on a real-time basis. Register 0x0D0C contains the information for REF A, Register 0x0D0D contains the information for REF AA, and so on to Register 0x0D13 for REF DD. Bit 7 of each register is the null indicator for that particular reference. If Bit 7 = 0, then the profile assignment for that particular reference is null. If Bit 7 = 1, then that particular reference is assigned to the profile (0 to 7) identified by Bits[6:4]. Note that Bits[6:4] are meaningless unless Bit 7 = 1. Table 22. Reference-to-Profile Table Reference Input A Reference Index 0 AA 1 B 2 BB 3 C 4 CC 5 D 6 DD 7 Profile Profile number (or null value) Profile number (or null value) Profile number (or null value) Profile number (or null value) Profile number (or null value) Profile number (or null value) Profile number (or null value) Profile number (or null value) Following a reset, the reference-to-profile assignment state machine is inactive to avoid improperly assigning a reference to a profile before the system clock stabilizes. The reason is that the state machine relies on accurate information from the reference monitors, which, in turn, rely on a stable system clock. Because the reference-to-profile assignment state machine is inactive at power-up, the user must initiate it manually by writing to the reference profile detect register (Address 0A0D). The state machine activates immediately, unless the system clock is not stabilized, in which case, activation occurs upon expiration of the system clock stability timer. Note that initialization of the state machine is on a per-reference basis. That is, each reference input is associated with an independent initialization control bit. When initialized for processing a reference, the state machine continuously monitors that reference until the occurrence of a device reset. This is true even when the user programs a reference for manual profile selection, in which case, the state machine associated with that particular reference operates with its activity masked. The masked background activity allows for seamless operation if the user subsequently reprograms the reference for automatic profile selection. Reference-to-Profile Assignment When a reference is programmed for manual profile assignment (see Register 0x0503 to Register 0x0506), the reference-to-profile assignment state machine simply puts the programmed manual profile number into the profile column of the reference-to-profile table (see Table 22) in the row associated with the appropriate reference. However, when the user programs a reference for automatic profile assignment, the state machine must figure out which profile to assign to the reference. As long as a null entry appears in the reference-to-profile table for a particular input reference, the validation logic for that reference enters a period estimation mode. Note that a null entry is the default state following a reset, but it also occurs when a reference redetect timer expires. The period estimation mode enables the validation logic to make a blind estimate of the period of the input reference with a tolerance of 0.1%. The validation logic remains in the period estimation mode until it successfully estimates the reference period. Upon a successful reference period measurement by the validation logic, the state machine compares the measured period to the nominal reference period programmed into each of the eight profiles. The state machine assigns the reference to the profile with the closest match to the measured period. If more than one profile exactly matches the reference period, then the state machine chooses the profile with the lowest numeric index. For example, if the reference period in both Profile 3 and Profile 5 matches the measured period, then Profile 3 is given the assignment. To safeguard against making a poor reference-to-profile assignment, the state machine ensures that the measured reference period is within 6.25% of the nominal reference period that appears in the closest match profile. Otherwise, the state machine does not make a profile assignment and leaves the null entry in the reference-to-profile table. Rev. G | Page 29 of 111 AD9548 Data Sheet As long as there are input references programmed for automatic profile assignment, and for which the profile assignment is null, the state machine continues to cycle through those references searching for a profile match. Furthermore, unless an input reference is assigned to a profile, it is considered invalid and excluded as a candidate for a reference switchover. REFERENCE SWITCHOVER An attractive feature of the AD9548 is its versatile reference switchover capability. The flexibility of the reference switchover functionality resides in a sophisticated prioritization algorithm coupled with register-based controls. This scheme provides the user with maximum control over the state machine that handles reference switchover. The main reference switchover control resides in the loop mode (Address 0x0A01). The user selection mode bits (Register 0x0A01, Bits[4:3]) allow the user to select one of the reference switchover state machine’s four operating modes, as follows: • • • • Automatic mode (Address A01, Bits[4:3] = 00) Fallback mode (Address 0A01, Bits[4:3] = 01) Holdover mode (Address 0A01, Bits[4:3] = 10) Manual mode (Address 0A01, Bits[4:3] = 11) In automatic mode, a fully automatic priority-based algorithm selects which reference is the active reference. When programmed for automatic mode, the device ignores the user selection reference bits (Register 0x0A01, Bits[2:0]). However, when programmed for any of the other three modes, the device makes use of the user reference bits. These bits specify a particular input reference (000 = REF A, 001 = REF AA ..., 111 = REF DD). In fallback mode, the user reference is the active reference whenever it is valid. Otherwise, the device switches to a new reference using the automatic, priority-based algorithm. In holdover mode, the user reference is the active reference whenever it is valid. Otherwise, the device switches to holdover mode. In manual mode, the user reference is the active reference whether it is valid or not. Note that, when using this mode, the user must program the reference-to-profile assignment (see Register 0x0503 to Register 0x0506) as manual for the particular reference declared as the user reference. The reason is that if the user reference fails and its redetect timer expires, then its profile assignment (shown in Table 22) becomes null. This means that the active reference (user reference) does not have an assigned profile, which places the AD9548 into an undefined state. The user also has the option to force the device directly into holdover or free-run operation via the user holdover and user free-run bits (Register 0x0A01, Bit 6 and Bit 5, respectively]). In free-run mode, the free running frequency tuning word register (Address 0x0300 to Address 0x0305) defines the DDS output frequency. In holdover mode, the DDS output frequency depends on the holdover control settings (see the Holdover section). Automatic Priority-Based Reference Switchover The AD9548 has a two-tiered, automatic, priority-based algorithm that is in effect for both automatic and fallback reference switchover. The algorithm relies on the fact that each reference profile contains both a selection priority and a promoted priority. The selection and promoted priority values range from 0 (highest priority) to 7 (lowest priority). The selection priority determines the order in which references are chosen as the active reference. The promoted priority is a separate priority value given to a reference only after it becomes the active reference. An automatic reference switchover occurs on failure of the active reference or when a previously failed reference becomes valid and its selection priority is higher than the promoted priority of the currently active reference (assuming that the automatic or fallback reference switchover is in effect). When performing an automatic reference switchover, the AD9548 chooses a reference based on the priority settings within the profiles. That is, the device switches to the reference with the highest selection priority (lowest numeric priority value). It does so by using the referenceto-profile table (see Table 22) to determine the reference associated with the profile exhibiting the highest priority. If multiple references share the same profile, then the device chooses the reference having the lowest index value. For example, if the A, B, and CC references (Index 0, Index 2, and Index 5, respectively) share the same profile, then a switchover to Reference A occurs because Reference A has the lowest index value. Note, however, that only valid references are included in switchover of the selection process. The switchover control logic ignores any reference with a status indication of invalid. When using multiple differential reference inputs, physically connect the reference input signal with the highest priority to the reference input with the lowest index value. For example, a differential signal on Reference Input B should not have a priority that exceeds a differential signal on Reference Input A. A differential reference on Reference Input C should not have a priority that exceeds a differential signal on Reference Input B, and a differential signal on Reference Input D should not have a priority that exceeds a differential signal on Reference Input C. A differential reference on Reference Input A has no priority restrictions. Table 23 shows four valid priority settings for four differential reference inputs. Table 23. Valid Differential Reference Priority Examples1 Reference Input A 0 0 3 2 1 Reference Input B 1 0 3 2 Reference Input C 2 0 4 3 Reference Input D 3 0 4 7 Any reference input configured for a CMOS input is exempt from these considerations. Rev. G | Page 30 of 111 Data Sheet AD9548 Priority 3 reference is active, its promoted priority of 1 is in effect. This is a higher priority than the newly validated reference’s priority of 2, so the switchover does not occur. This mechanism enables the user to give references preferential treatment while they are selected as the active reference. An example of promoted vs. nonpromoted priority switching appears in state diagram form in Figure 37. Figure 38 shows a block diagram of the interrelationship between the reference inputs, monitors, validation logic, profile selection, and priority selection functionality. INITIAL STATE ALL VALID A VALID PRIORITY TABLE INPUT PRIORITY PROMOTED A 0 0 B 1 0 C 2 1 D 3 2 A ACTIVE A FAULTED B ACTIVE B VALID COMMON WITHOUT PROMOTION WITH PROMOTION A VALID B FAULTED C ACTIVE B VALID 08022-011 The promoted priority parameter allows the user to assign a higher priority to a reference after it becomes the active reference. For example, suppose four references have a selection priority of 3 and a promoted priority of 1, and the remaining references have a selection priority or 2 and a promoted priority of 2. Now, assume that one of the Priority 3 references becomes active because all of the Priority 2 references have failed. Sometime later, however, a Priority 2 reference becomes valid. The switchover logic normally attempts to automatically switch over to the Priority 2 reference because it has higher priority than the presently active Priority 3 reference. However, because the Figure 37. Example of Priority Promotion PROFILE SELECTION VALIDATION LOGIC PRIORITY SELECTION LOOP CONTROLLER … … MONITORS ÷R TDC 08022-012 C/CC … B/BB ……… A/AA D/DD Figure 38. Reference Clock Block Diagram Rev. G | Page 31 of 111 AD9548 Data Sheet Phase build-out reference switching is the term given to a reference switchover that completely masks any phase difference between the previous reference and the new reference. That is, there is virtually no phase change detectable at the output when a phase build-out switchover occurs. The AD9548 handles phase build-out switching based on whether the new reference is a phase master. A phase master is any reference with a selection priority value that is less than the phase master threshold priority value (that is, higher priority). The phase master threshold priority value resides in the phase build-out switching register (Address 0x0507), whereas the selection priority resides in the profile registers (Address 0x0600 to Address 0x07FF). By default, the phase master threshold priority is 0; therefore, no references can be phase masters until the user changes the phase master threshold priority. Whenever the AD9548 switches from one reference to another, it compares the selection priority value stored in the profile assigned to the new reference with the phase master threshold priority. The AD9548 performs a phase build-out switchover only if the new reference is not a phase master. Hitless Reference Switching (Phase Slew Control) Hitless reference switching is the term given to a reference switchover that limits the rate of change of the phase of the output clock while the PLL is in the process of acquiring phase lock. This prevents the output frequency offset from becoming excessive. The all-digital nature of the DPLL core (see the Digital PLL (DPLL) Core section) gives the user numerical control of the rate at which phase changes occur at the DPLL output. When enabled, a phase slew controller monitors the phase difference between the feedback and reference inputs to the DPLL. The phase slew controller has the ability to place a user specified limit on the rate of change of phase, thus providing a mechanism for hitless reference switching. The user sets a limit on the rate of change of phase by storing the appropriate value in the 16-bit phase slew rate limit register (Address 0x0316 to Address 0x0317). The 16-bit word (representing ns/sec) puts an upper bound on the rate of change of the phase at the output of the DPLL during a reference switchover. A phase slew rate value of 0 (default) disables the phase slew controller. The accuracy of the phase slew controller depends on both the phase slew limit value and the system clock frequency. Generally, an increase in the phase slew rate limit value or a decrease in the system clock frequency tends to reduce the error. As such, the accuracy is best for the largest phase slew limit value and the lowest system clock frequency. For example, assuming the use of a 1 GHz system clock, a phase slew limit value of 315 ns/sec (or more) ensures an error of less than 10%, whereas a phase slew rate limit value above ~3100 ns/sec ensures an error of less than 1%. On the other hand, assuming the use of a 500 MHz system clock, the same phase slew rate limit values ensure an error of less than 5% or 0.5%, respectively. DIGITAL PLL (DPLL) CORE DPLL Overview A diagram of the digital PLL core of the AD9548 appears in Figure 39. The phase/frequency detector, feedback path, lock detectors, phase offset, and phase slew rate limiting that comprise this second generation DPLL are all digital implementations. LOCK DETECT PHASE SLEW LIMIT DPPL CORE CLOSED-LOOP PHASE OFFSET REF A fR R+1 REF DD fTDC TDC AND PFD DIGITAL LOOP FILTER DDS/ DAC fDDS 2 DACOUT S + 1 + U/V Figure 39. Digital PLL Core The start of the DPLL signal chain is the reference signal, fR, which is the frequency of the reference input. A reference prescaler reduces the frequency of this signal by an integer factor, R + 1, where R is the 30-bit value stored in the appropriate profile register and 0 ≤ R ≤ 1,073,741,823. Therefore, the frequency at the output of the R-divider (or the input to TDC) is f TDC fR R 1 A time-to-digital converter (TDC) samples the output of the R-divider. The TDC/PFD produces a time series of digital words and delivers them to the digital loop filter. The digital loop filter offers the following advantages: Determination of the filter response by numeric coefficients rather than by discrete component values The absence of analog components (R/L/C), which eliminates tolerance variations due to aging The absence of thermal noise associated with analog components The absence of control node leakage current associated with analog components (a source of reference feedthrough spurs in the output spectrum of a traditional analog PLL) The digital loop filter produces a time series of digital words at its output and delivers them to the frequency tuning input of a DDS, with the DDS replacing the function of the VCO in an analog PLL. The digital words from the loop filter tend to steer the DDS frequency toward frequency and phase lock with the input signal (fTDC). The DDS provides an analog output signal via an integrated DAC, effectively mimicking the operation of an analog VCO. Rev. G | Page 32 of 111 08022-013 Phase Build-Out Reference Switching Data Sheet AD9548 The DPLL includes a feedback divider that causes the DDS to operate at an integer-plus-fractional multiple (S + 1 + U/V) of fTDC. S is the 30-bit value stored in the profile register and has a range of 7 ≤ S ≤ 1,073,741,823. U and V are the 10-bit numerator and denominator values of the optional fractional divide component and are also stored in the profile register. Together they establish the nominal DDS frequency (fDDS), given by fR U S 1 R 1 V Normally, fractional-N designs exhibit distinctive phase noise and spurious artifacts resulting from the modulation of the integer divider based on the fractional value. Such is not the case for the AD9548 because it uses a purely digital means to determine phase errors. Because the phase errors incurred by modulating the feedback divider are deterministic, it is possible to compensate for them digitally. The result is a fractional-N PLL with no discernable modulation artifacts. TDC/PFD The TDC is a highly integrated functional block that incorporates both analog and digital circuitry. There are two pins associated with the TDC that the user must connect to external components. Figure 40 shows the recommended component values and their connections. For best performance, place components as close as possible to the device pins. Components with low effective series resistance (ESR) and low parasitic inductance yield the best results. The AD9548 loop filter is a third order digital IIR filter that is analogous to the third order analog loop shown in Figure 41. 58 TDC_VRB Note that the incremental phase offset is completely independent of the offset programmed into the fixed phase lock offset register. However, if the phase slew limiter is active (see the Hitless Reference Switching (Phase Slew Control) section), then any instantaneous change in closed-loop phase offset (fixed or incremental) will be subject to possible slew limitation by the action of the phase slew limiter. Programmable Digital Loop Filter AD9548 57 In addition, the user can adjust the closed-loop phase offset (positive or negative) in incremental fashion. To do so, program the desired step size in the 16-bit incremental phase lock offset step size register (Address 0x0314 to Address 0x0315). This is an unsigned number that represents units of picoseconds. The programmed step size is added to the current closed-loop phase offset each time the user writes a Logic 1 to the increment phase offset bit (Register 0x0A0C, Bit 0). Conversely, the programmed step size is subtracted from the current closed-loop phase offset each time the user writes a Logic 1 to the decrement phase offset bit (Register 0x0A0C, Bit 1). The serial input/output port control logic clears both of these bits automatically. The user can remove the incrementally accumulated phase by writing a Logic 1 to the reset incremental phase offset bit (Register 0x0A0C, Bit 2), which is also cleared automatically. Alternatively, rather than using the serial input/output port, the multifunction pins can be set up to perform the increment, decrement, and clear functions. TDC_VRT R3 0.1µF C1 R2 C3 C2 10µF 08022-015 f DDS (Address 0x030F to Address 0x0313). The 40-bit word is a signed (twos complement) number that represents units of picoseconds. 0.1µF 08022-014 Figure 41. Third Order Analog Loop Filter 0.1µF Figure 40. TDC Pin Connections The phase-frequency detector (PFD) is an all-digital block. It compares the digital output from the TDC (which relates to the active reference edge) with the digital word from the feedback block (which relates to the rollover edge of the DDS accumulator after division by the feedback divider). It uses a digital code pump and digital integrator (rather than a conventional charge pump and capacitor) to generate the error signal that steers the DDS frequency toward phase lock. The filter requires four coefficients as shown in Figure 42. The AD9548 evaluation board software automatically generates the required loop filter coefficient values based on the user’s design criteria. The Calculating Digital Filter Coefficients section contains the design equations for calculating the loop filter coefficients manually. FRACTIONAL (16-BIT) 1/2x (6-BIT) 2x (3-BIT) FRACTIONAL (17-BIT) 2x (4-BIT) 1/2x (6-BIT) FRACTIONAL (17-BIT) FRACTIONAL (15-BIT) 1/2x (6-BIT) 1/2x (5-BIT) Closed-Loop Phase Offset 51 IN Rev. G | Page 33 of 111 LOOP FILTER (THIRD ORDER IIR) Figure 42. Third Order Digital IIR Loop Filter 48 OUT 08022-016 The all-digital nature of the TDC/PFD provides for numerical control of the phase offset between the reference and feedback edges. This allows the user to adjust the relative timing of the distribution output edges relative to the reference input edges by programming the 40-bit fixed phase lock offset register AD9548 Data Sheet Each coefficient has a fractional component representing a value from 0 up to, but not including, unity. Each coefficient also has an exponential component representing a power of 2 with a negative exponent. That is, the user enters a positive number (x) that the hardware interprets as a negative exponent of two (2−x). Thus, the , and coefficients always represent values less than unity. The coefficient, however, has two additional exponential components, but the hardware interprets these as a positive exponent of 2 (that is, 2x). This allows the coefficient to be a value greater than unity. The positive exponent appears as two separate terms in order to provide sufficient dynamic range. DPLL Phase Lock Detector magnitude relative to the phase threshold value, that determines whether to fill or drain. If more filling is taking place than draining, the water level in the tub eventually rises above the high water mark (+1024), which causes the phase lock detector to indicate lock. If more draining is taking place than filling, then the water level in the tub eventually falls below the low water mark (−1024), which causes the phase lock detector to indicate unlock. The ability to specify the threshold level, fill rate, and drain rate enables the user to tailor the operation of the phase lock detector to the statistics of the timing jitter associated with the input reference signal. PREVIOUS STATE LOCKED UNLOCKED 2048 The phase lock detector behaves in a manner analogous to water in a tub (see Figure 43). The total capacity of the tub is 4096 units with −2048 denoting empty, 0 denoting the 50% point, and +2048 denoting full. The tub also has a safeguard to prevent overflow. Furthermore, the tub has a low water mark at −1024 and a high water mark at +1024. To change the water level, the user adds water with a fill bucket or removes water with a drain bucket. The user specifies the size of the fill and drain buckets via the 8-bit fill rate and drain rate values in the profile registers. The water level in the tub is what the lock detector uses to determine the lock and unlock conditions. Whenever the water level is below the low water mark (−1024), the detector indicates an unlock condition. Conversely, whenever the water level is above the high water mark (+1024), the detector indicates a lock condition. While the water level is between the marks, the detector simply holds its last condition. This concept appears graphically in Figure 43 with an overlay of an example of the instantaneous water level (vertical) vs. time (horizontal) and the resulting lock/unlock states. During any given PFD phase error sample, the detector either adds water with the fill bucket or removes water with the drain bucket (one or the other but not both). The decision of whether to add or remove water depends on the threshold level specified by the user. The phase lock threshold value is a 16-bit number stored in the profile registers and is expressed in picoseconds. Thus, the phase lock threshold extends from 0 ns to ±65.535 ns and represents the magnitude of the phase error at the output of the PFD. The phase lock detector compares each phase error sample at the output of the PFD to the programmed phase threshold value. If the absolute value of the phase error sample is less than or equal to the programmed phase threshold value, then the detector control logic dumps one fill bucket into the tub. Otherwise, it removes one drain bucket from the tub. Notice that it is not the polarity of the phase error sample, but its LOCK LEVEL 1024 0 FILL RATE DRAIN RATE UNLOCK LEVEL –1024 –2048 08022-017 The DPLL contains an all-digital phase lock detector. The user controls the threshold sensitivity and hysteresis of the phase detector via the profile registers. Figure 43. Lock Detector Diagram Note that whenever the AD9548 enters the free-run or holdover mode, the DPLL phase lock detector indicates unlocked. In addition, whenever the AD9548 performs a reference switchover, the state of the lock detector prior to the switch is preserved during the transition period. DPLL Frequency Lock Detector The operation of the frequency lock detector is identical to that of the phase lock detector. The only difference is that the fill or drain decision is based on the period deviation between the reference and feedback signals of the DPLL instead of the phase error at the output of the PFD. The frequency lock detector uses a 24-bit frequency threshold register specified in units of picoseconds. Thus, the frequency threshold value extends from 0 μs to ±16.777215 μs. It represents the magnitude of the difference in period between the reference and feedback signals at the input to the DPLL. For example, if the reference signal is 1.25 MHz and the feedback signal is 1.38 MHz, then the period difference is approximately 75.36 ns (|1/1,250,000 − 1/1,380,000| ≈ 75.36 ns). DIRECT DIGITAL SYNTHESIZER DDS Overview One of the primary building blocks of the digital PLL is a direct digital synthesizer (DDS). The DDS behaves like a sinusoidal signal generator. The frequency of the sinusoid generated by the DDS is determined by a frequency tuning word (FTW), which is a digital (that is, numeric) value. Unlike an analog sinusoidal generator, a DDS uses digital building blocks and operates as a sampled system. Thus, it requires a sampling clock (fS) that serves as the fundamental timing source of the DDS. The accumulator behaves as a modulo-248 counter with a programmable step size (FTW). A block diagram of the DDS appears in Figure 44. Rev. G | Page 34 of 111 Data Sheet AD9548 48-BIT ACCUMULATOR PHASE OFFSET 48 48 19 48 D 19 14 ANGLE TO AMPLITUDE CONVERSION Q DAC+ DAC (14-BIT) DAC– 08022-018 FREQUENCY TUNING WORD (FTW) 16 fS Figure 44. DDS Block Diagram AVDD3 The input to the DDS is the 48-bit FTW. The FTW serves as a step size value. On each cycle of fS, the accumulator adds the value of the FTW to the running total at its output. For example, given FTW = 5, the accumulator counts by fives, incrementing on each fS cycle. Over time, the accumulator reaches the upper end of its capacity (248 in this case), at which point, it rolls over but retains the excess. The average rate at which the accumulator rolls over establishes the frequency of the output sinusoid. The average rollover rate of the accumulator establishes the output frequency (fDDS) of the DDS and is given by 21 22 ISCALE CURRENT SWITCH ARRAY CODE IFS ( ) 214 – 1 DACOUTP 18 Solving this equation for FTW yields IFS (1– CODE 214 – 1 ) 19 DACOUTN SWITCH CONTROL 50Ω 14 50Ω GND GND Note that the minimum DAC output frequency is 62.5 MHz; therefore, normal operation requires an FTW that yields an output frequency in excess of this lower bound. Figure 45. DAC Output Pins The value of IFS is programmable via the 10-bit DAC full-scale current word in the DAC current register (Address 0x0213 to Address 0x0214). The value of the 10-bit word (ISCALE) sets IFS according to the following formula: 3 I I FS 120 μA 72 16 SCALE DDS Phase Offset The relative phase of the sinusoid generated by the DDS is numerically controlled by adding a phase offset word to the output of the DDS accumulator. This is accomplished via the open-loop phase offset register (Address 0x030D to Address 0x030E), which is a programmable 16-bit value (Δphase). The resulting phase offset, ΔΦ (in radians), is given by phase Φ 2 16 2 Phase offset and relative time offset are directly related. The time offset is (phase/216)/fDDS (in seconds), where fDDS is the output frequency of the DDS (in hertz). TUNING WORD PROCESSING The frequency tuning words that dictate the output frequency of the DDS come from one of three sources (see Figure 46). The free running frequency tuning word register The output of the digital loop filter The output of the tuning word history processor TUNING WORD HISTORY PROCESSOR TUNING WORD HISTORY FREE-RUN TUNING WORD TUNING WORD UPDATE The output of the digital core of the DDS is a time series of numbers representing a sinusoidal waveform. The DAC translates the numeric values to an analog signal. The DAC output signal appears at two pins that constitute a balanced current source architecture (see Figure 45). FROM DIGITAL LOOP FILTER TUNING WORD ROUTING CONTROL TUNING WORD CLAMP LOWER TUNING WORD UPPER TUNING WORD Figure 46. Tuning Word Processing Rev. G | Page 35 of 111 TO DDS 08022-070 For example, given that fS = 1 GHz and fDDS = 155.52 MHz, then FTW = 43,774,988,378,041 (0x27D028A1DFB9). 08022-019 CODE DAC Output CURRENT MIRROR IFS FTW f DDS 48 f S 2 f FTW round 2 48 DDS f S 10 AD9548 Data Sheet When the DPLL is in free-run mode, the DDS tuning word is the value stored in the free running frequency tuning word register (Address 0x0300 to Address 0x0305). When the DPLL is operating normally (closed loop), the DDS tuning word comes from the output of the digital loop filter, which changes dynamically in order to maintain phase lock with the input reference signal (assuming that the device has not performed an automatic switch to holdover mode). When the DPLL is in holdover mode, the DDS tuning word depends on a historical record of past tuning words during the time that the DPLL operated in closed-loop mode. However, regardless of the operating mode, the DDS output frequency is ultimately subject to the boundary conditions imposed by the frequency clamp logic, as explained in the Frequency Clamp section. Frequency Clamp The user controls the frequency clamp boundaries via the pull-in range limits registers (Address 0x0307 to Address 0x030C). These registers allow the user to fix the DDS output frequency between an upper and lower bound with a granularity of 24 bits. Note that these upper and lower bounds apply regardless of the frequency tuning word that appears at the input to the DDS. The register value relates to the absolute upper or lower frequency bound (fCLAMP) as fCLAMP = fS × (N/224) where N is the value stored in the upper- or lower-limit register, and fS is the system sample rate. Even though the frequency clamp limits put a bound on the DDS output frequency, the DPLL is still free to steer the DDS frequency within the clamp limits. The default register values set the clamp range from 0 Hz (dc) to fS, effectively eliminating the frequency clamp functionality until the user alters the register values. Frequency Tuning Word History The AD9548 has the ability to track the history of the tuning word samples generated by the DPLL digital loop filter output. It does so by periodically computing the average tuning word value over a user specified interval. The user programs the interval via the 24-bit history accumulation timer register (Address 0x0318 to Address 0x031A). This 24-bit value represents a time interval (TAVG) in milliseconds that extends from 1 ms to a maximum of 4:39:37.215 (hr:min:sec). Note that history accumulation timer = 0 should not be programmed because it may cause improper device operation. The control logic performs a calculation of the average tuning word during the TAVG interval and stores the result in the holdover history register (Address 0D14 to Address 0D19). Computation of the average for each TAVG interval is independent of the previous interval (that is, the average is a memoryless average as opposed to a true moving average). In addition, at the end of each TAVG interval, the device generates an internal strobe pulse. The strobe pulse sets the history updated bit in the IRQ monitor register (assuming the bit is enabled via the IRQ mask register). Furthermore, the strobe pulse is available as an output signal via the multifunction pins (see the Multifunction Pins (M0 to M7) section). History accumulation begins whenever the device switches to a new reference. The user should be aware that the first tuning word history interval includes the initial DPLL acquisition, and the DPLL tuning word values during acquisition can corrupt the average value of the first holdover history interval. To avoid holdover history corruption during loop acquisition, the user can clear the holdover history after DPLL phase lock by setting Bit 2 of Register 0x0A03. By default, the device clears any previous history when it switches to a new reference. Furthermore, the user can clear the tuning word history under software control via Register 0x0A03, Bit 2, or under hardware control via the multifunction pins (see the Multifunction Pins (M0 to M7) section). However, the user has the option of programming the device to retain (rather than clear) the old history by setting the persistent history bit (Register 0x031B, Bit 3). Whenever the tuning word history is nonexistent (that is, after a power-up, reset, or switchover to a new reference with the persistent history bit cleared), the device waits for the history accumulation timer (TAVG) to expire before storing the first history value in the holdover history register. In cases where TAVG is quite large (4½ hours, for example), a problem arises in that the first averaged result does not become available until the full TAVG interval passes. Thus, it is possible that as much as 4½ hours can elapse before the first averaged result is available. If the device has to switch to holdover mode during this time, a tuning word history is not available. To alleviate this problem, the user has access to the incremental average bits in the history mode register (Register 0x031B, Bits[2:0]). If the history has been cleared, then this 3-bit value, K (0 ≤ K ≤ 7), specifies the number of intermediate averages to take during the first, and only the first, TAVG interval. When K = 0, no intermediate averages are calculated; therefore, the first average occurs after interval TAVG (the default operating mode). However, if K = 4, for example, sixteen intermediate averages are taken during the first TAVG interval. These average computations occur at TAVG/16, TAVG/8, TAVG/4, TAVG/2, and TAVG (notice that the denominator exhibits a sequence of powers of 2 beginning with TAVG/2K). The calculation of intermediate averages occurs only during the first TAVG interval. All subsequent average computations occur at evenly spaced intervals of TAVG. LOOP CONTROL STATE MACHINE The loop control state machine is responsible for monitoring, initiating, and sequencing changes to the DPLL loop. Generally, it automatically controls the transition between input references and the entry and exit of holdover mode. In controlling loop state changes, the state machine also arbitrates the application Rev. G | Page 36 of 111 Data Sheet AD9548 of new loop filter coefficients, divider settings, and phase detector offsets based on the profile settings. The user can manually force the device into holdover or free-run mode via the loop mode register (Address 0x0A01), as well as force the selection of a specific input reference. Switchover Switchover occurs when the loop controller switches directly from one input reference to another. Functionally, the AD9548 handles a reference switchover by briefly entering holdover mode and then immediately recovering. During the switchover event, however, the AD9548 preserves the status of the lock detectors to avoid phantom unlock indications. Holdover The holdover state of the DPLL is an open-loop operating mode. That is, the device no longer operates as a closed-loop system. Instead, the output frequency remains constant and is dependent on the device programming and availability of tuning word history. If a tuning word history exists (see the Frequency Tuning Word History section), then the holdover frequency is the average frequency just prior to entering the holdover state. If there is no tuning word history, then the holdover frequency depends on the state of the single sample fallback bit in the history mode register (Register 0x031B, Bit 4). If the single sample fallback bit is Logic 0, then the holdover frequency is the frequency defined in the free running frequency tuning word register (Address 0x0300 to Address 0x0305). If the single sample fallback bit is Logic 1, then the holdover frequency is the last instantaneous frequency output by the DDS just prior to the device entering holdover mode (note that this is not the average frequency prior to holdover). The initial holdover frequency accuracy depends on the loop bandwidth of the DPLL and the time elapsed to compute a tuning word history. The longer the historical average, the more accurate the initial holdover frequency (assuming a drift-free system clock). Furthermore, the stability of the system clock establishes the stability and long-term accuracy of the holdover output frequency. Another consideration is the 48-bit frequency tuning resolution of the DDS and its relationship to fractional frequency error, ∆fO/fO, as follows: f ∆f O = 49 S fO 2 fO where fS is the sample rate of the output DAC, and fO is the DDS output frequency. The worst-case scenario is maximum fS (1 GHz) and minimum fO (62.5 MHz), which yields ∆fO/fO = 2.8 × 10−14, less than one part in 10 trillion. Recovery from Holdover When in holdover and a valid reference becomes available, the device exits holdover operation. The loop state machine restores the DPLL to closed-loop operation, locks to the selected reference, and sequences the recovery of all the loop parameters based on the profile settings for the active reference. Note that, if the user holdover bit (Register 0x0A01, Bit 6) is set, the device does not automatically exit holdover when a valid reference is available. However, automatic recovery can occur after clearing the user holdover bit. SYSTEM CLOCK INPUTS Functional Description The system clock circuit provides a low jitter, stable, high frequency clock for use by the rest of the chip. The user has the option of directly driving the SYSCLKx inputs with a high frequency clock source at the desired system clock rate. Alternatively, the SYSCLKx input can be configured to operate in conjunction with the internal SYSCLK PLL. The SYSCLK PLL can synthesize the system clock by means of a crystal resonator connected across the SYSCLKx input pins or by means of direct application of a low frequency clock source. The SYSCLKx inputs are internally biased to a dc level of ~1 V. Take care to ensure that any external connections do not disturb the dc bias because this may significantly degrade performance. Generally, the recommendation is that the SYSCLKx inputs be ac-coupled to the signal source (except when using a crystal resonator). Low Loop Bandwidth Applications Using a TCXO/OCXO For many applications, the use of a crystal oscillator is a costeffective and simple choice. The stability is good enough to support loop bandwidths down to 50 Hz, and the holdover performance is good enough for all except the most demanding applications. In cases where Stratum 2 or Stratum 3 holdover performance is needed, or in cases where the loop bandwidth must be <50 Hz, either a TCXO or OCXO must be used. If the loop bandwidths are lower than 10 mHz, an OCXO must be used. Choose a TCXO/OCXO with a high output frequency and CMOS output to achieve the best performance. The AN-1079 Application Note, Determining the Maximum Tolerable Frequency Drift Rate of the AD9548 System Clock in Low Loop Bandwidth Applications, discusses system clock performance considerations for low loop bandwidth applications. When interfacing the TCXO/OCXO, a voltage divider on the output should be used to reduce the voltage swing to 1 V p-p, and that signal should be ac-coupled to the SYSCLKP pin. The SYSCLKN pin can be bypassed to ground with a 0.01 µF capacitor. Choosing the System Clock Oscillator Frequency The best performance of the AD9548 is achieved when the system clock is not an integer multiple of the DDS output frequency. As an example, using a 19.44 MHz oscillator for the system clock in a 156.25 MHz Ethernet application yields better performance than a 25 MHz oscillator. Another good system clock choice for many communications applications is a 49.152 MHz crystal used in IEEE 1394 (FireWire) because nearly all output frequencies are not integer related to this frequency, and the crystal is readily available. Rev. G | Page 37 of 111 AD9548 Data Sheet LF SYSCLKN 52 SYSCLK_VREG SYSCLK_LF 48 49 2× LOCK DETECT ÷M PFD AND CHARGE PUMP XTAL VCO CALIBRATION LOOP FILTER SYSCLKP 53 ÷N SYSTEM CLOCK 08022-020 HF Figure 47. System Clock Block Diagram System Clock Details A block diagram of the system clock appears in Figure 47. The signal at the SYSCLKx input pins becomes the internally buffered DAC sampling clock (fS) via one of three paths. • • • High frequency direct (HF) Low frequency synthesized (LF) Crystal resonator synthesized (XTAL) Note that both the LF and XTAL paths require the use of the SYSCLK PLL (see the SYSCLK PLL Multiplier section). The main purpose of the HF path is to allow the direct use of a high frequency (500 MHz to 1 GHz) external clock source for clocking the AD9548. This path is optimized for high frequency and low noise floor. Note that the HF input also provides a path to SYSCLK PLL (see the SYSCLK PLL Multiplier section), which includes an input divider (M) programmable for divide-by -1, -2, -4, or -8. The purpose of the divider is to limit the frequency at the input to the PLL to less than 150 MHz (the maximum PFD rate). The LF path permits the user to provide an LVPECL, LVDS, CMOS, or sinusoidal low frequency clock for multiplication by the integrated SYSCLK PLL. The LF path handles input frequencies from 3.5 MHz up to 100 MHz. However, when using a sinusoidal input signal, it is best to use a frequency in excess of 20 MHz. Otherwise, the resulting low slew rate can lead to substandard noise performance. Note that the LF path includes an optional 2× frequency multiplier to double the rate at the input to the SYSCLK PLL and potentially reduce the PLL in-band noise. However, to avoid exceeding the maximum PFD rate of 150 MHz, using the 2× frequency multiplier is valid only for input frequencies below 125 MHz. The XTAL path enables the connection of a crystal resonator (typically 10 MHz to 50 MHz) across the SYSCLKx input pins. An internal amplifier provides the negative resistance required to induce oscillation. The internal amplifier expects a 3.2 mm × 2.5 mm AT cut, fundamental mode crystal with a maximum motional resistance of 100 Ω. The following crystals, listed in alphabetical order, may meet these criteria. Note that, whereas these crystals may meet the preceding criteria according to their data sheets, Analog Devices, Inc., does not guarantee their operation with the AD9548, nor does Analog Devices endorse one crystal manufacturer/supplier over another. • • • • • • AVX/Kyocera CX3225SB ECS ECX-32 Epson/Toyocom TSX-3225 Fox FX3225BS NDK NX3225SA Siward SX-3225 SYSCLK PLL MULTIPLIER The SYSCLK PLL multiplier is an integer-N design and relies on an integrated LC tank and VCO. It provides a means to convert a low frequency clock input to the desired system clock frequency, fS (900 MHz to 1 GHz). The SYSCLK PLL multiplier accepts input signals between 3.5 MHz and 500 MHz, but frequencies in excess of 150 MHz require the M-divider to ensure compliance with the maximum PFD rate (150 MHz). The PLL contains a feedback divider (N) that is programmable for divide values between 6 and 255. The nominal VCO gain is 70 MHz/V. Lock Detector The SYSCLK PLL has a built-in lock detector. Register 0x0100, Bit 2 determines whether the lock detector is active. When active (default), the user controls the sensitivity of the lock detector via the lock detect divider bits (Register 0x0100, Bits[1:0]). Note that 0 must be written to the system clock stability timer (Register 0x0106 to Register 0x0108) whenever the lock detector is disabled (Register 0x0100, Bit 2 = 1). The SYSCLK PLL phase detector operates at the PFD rate, which is fVCO/N. Each PFD sample indicates whether the reference and feedback signals are phase aligned (within a certain threshold range). While the PLL is in the process of acquiring a lock condition, the PFD samples typically consist of an arbitrary sequence of in-phase and out-of-phase indications. As the PLL approaches complete phase lock, the number of consecutive in-phase PFD Rev. G | Page 38 of 111 Data Sheet AD9548 samples grows larger. Therefore, one way of indicating a locked condition is to count the number of consecutive in-phase PFD samples and, if it exceeds a certain value, then declare the PLL locked. This is exactly the role of the lock detect divider bits. When the lock detector is enabled (Register 0x0100, Bit 2 = 0), the lock detect divider bits determine the number of consecutive in-phase decisions required (128, 256, 512, or 1024) before the lock detector declares a locked condition. The default setting is 128. Charge Pump The charge pump operates in either automatic or manual mode based on the charge pump mode bit (Register 0x0100, Bit 6). When Register 0x0100, Bit 6 = 0, the AD9548 automatically selects the appropriate charge pump current based on the N-divider value. Note that the user cannot control the charge pump current bits (Register 0x0100, Bits[5:3]) in automatic mode. When Register 0x0100, Bit 6 = 1, the user determines the charge pump current via the charge pump current bits (Register 0x0100, Bits[5:3]). The charge pump current varies from 125 μA to 1 mA in 125 μA steps. The default setting is 500 μA. SYSCLK PLL Loop Filter The AD9548 has an internal second order loop filter that establishes the loop dynamics for input signals between 12.5 MHz and 100 MHz. By default, the device uses the internal loop filter. However, an external loop filter option is available by setting the external loop filter enable bit (Register 0x0100, Bit 7). This bypasses the internal loop filter and allows the device to use an externally connected second order loop filter, as shown in Figure 48. AD9548 SYSCLK_VREG SYSCLK_LF 48 49 For example, assuming that N = 40, ICP = 0.5 mA, fOL = 400 kHz, and Φ = 50°, then the loop filter calculations yield R1 = 3.31 kΩ, C1 = 330 pF, and C2 = 50.4 pF. System Clock Period Many of the user programmable parameters of the AD9548 have absolute time units. To make this possible, the AD9548 requires a priori knowledge of the period of the system clock. To accommodate this requirement, the user programs the 21-bit nominal system clock period in the nominal SYSCLK period registers (Address 0x0103 to Address 0x0105). The contents of this register reflect the actual period of the system clock in femtoseconds. The user must properly program this register to ensure proper operation of the device because many of its subsystems rely on this value. System Clock Stability Timer The system clock stability timer (Register 0x0106 to Register 0x0108) is a 20-bit value programmed in milliseconds. If the programmed timer value is 0, then the timer immediately indicates that it has timed out. If the programmed timer value is a nonzero value and the SYSCLK PLL is enabled, then the timer starts timing when the SYSCLK PLL lock detector indicates lock and times out after the prescribed period. However, when the user disables the SYSCLK PLL, then the timer ignores the SYSCLK PLL lock detector and starts timing as soon as the SYSCLK PLL is disabled. The user can monitor the status of the stability timer via Register 0x0D01, Bit 4, via the multifunction pins or via the IRQ pin. Note that the system clock stability timer must be programmed before the SYSCLK PLL is either activated or disabled. SYSCLK PLL Calibration C1 C2 08022-021 R1 Figure 48. External Loop Filter Schematic To determine the external loop filter components, the user decides on the desired open-loop bandwidth (fOL) and phase margin (φ). These parameters allow calculation of the loop filter components, as follows: R1 = πNfOL 1 1 + ICP K VCO sin(φ ) C1 = ICP K VCO tan(φ ) 2N (πfOL )2 C2 = N is the programmed feedback divider value. fOL is the desired open-loop bandwidth (in hertz). Φ is the desired phase margin (in radians). ICP K VCO 1 − sin(φ ) N (2πfOL )2 cos(φ ) where: KVCO is 7 × 107 V/ns (typical). ICP is the programmed charge pump current (amperes). When using the SYSCLK PLL, it is necessary to calibrate the LC VCO to ensure that the PLL can remain locked to the system clock input signal. Assuming the presence of either an external SYSCLK input signal or a crystal resonator, the calibration process executes after the user sets and then clears the calibrate system clock bit in the cal/sync register (Register 0x0A02, Bit 0). During the calibration process, the device calibrates the VCO amplitude and frequency. The status of the system clock calibration process is user accessible via the system clock register (Register 0x0D01, Bit 1). It is also available via the IRQ monitor register (Register 0D02, Bit 1) provided the status bit is enabled via the IRQ mask register. When the calibration sequence is complete, the SYSCLK PLL eventually attains a lock condition, at which point the system clock stability timer begins its countdown sequence. Expiration of the timer indicates that the SYSCLK PLL is stable, which is reflected in the system clock register (Register 0x0D01, Bit 4). Rev. G | Page 39 of 111 AD9548 Data Sheet Note that the monitors/detectors associated with the input references (REFA/AA – REFD/DD) are internally disabled until the SYSCLK PLL indicates that it is stable. CLOCK DISTRIBUTION The clock distribution block of the AD9548 provides an integrated solution for generating multiple clock outputs based on frequency dividing the DPLL output. The distribution output consists of four channels (OUT0 to OUT3). Each of the four output channels has a dedicated divider and output driver, as appears in Figure 49. CLKINP CLKINN SYNC CONTROL Clock Dividers The output clock distribution dividers are referred to as Q0 to Q3, corresponding to the OUT0 to OUT3 output channels, respectively. Each divider is programmable with 30 bits of division depth. The actual divider ratio is one more than the programmed register value; therefore, a register value of 3, for example, results in a divide ratio of 4. Thus, each divider offers a range of divide ratios from 1 to 230 (1 to 1,073,741,824). SYNC SOURCE RESET ENABLE 4 Super-Nyquist operation is viable as long as the image frequency does not exceed the 800 MHz input range of the receiver. Furthermore, to provide acceptable jitter performance, which is a consideration for image signals with low amplitude, the signal at the CLKINx input must meet the minimum slew rate requirements. With an even divide ratio, the output signal always exhibits a 50% duty cycle. When the clock divider is bypassed (a divide ratio of 1), the output duty cycle is the same as the input duty cycle. Odd output divide ratios (excluding 1) exhibit automatic duty cycle correction given by ENABLE n/MODEn 4 4 Q0 OUT_RSET Output Duty Cycle OUT0P where N (which must be an odd number) is the divide ratio and X is the normalized fraction of the high portion of the input period (that is, 0 < X < 1). OUT0N OUT0 OUT1P OUT1N OUT2 OUT2P OUT2N OUT3 OUT3P OUT3N For example, if N = 5 and the input duty cycle is 20% (X = 0.2), then the output duty cycle is 44%. Note that, when the user programs an output as noninverting, then the device adjusts the falling edge timing to accomplish the duty cycle correction. Conversely, the device adjusts the rising edge timing for an inverted output. 08022-022 OUT1 N 2 X 1 2N Figure 49. Clock Distribution Output Power-Down Clock Input (CLKINx) The clock input handles input signals from a variety of logic families (assuming proper terminations and sufficient voltage swing). It also handles sine wave input signals such as those delivered by the DAC reconstruction filter. Its default operating frequency range is 62.5 MHz to 500 MHz. Super-Nyquist Operation Typically, the maximum usable frequency at the DAC output is about 45% of the system clock frequency. However, because it is a sampled DAC, its output spectrum contains Nyquist images. Of particular interest are the images appearing in the first Nyquist zone (50% to 100% of the system clock frequency). Super-Nyquist operation takes advantage of these higher frequencies, but this implies that the CLKINx input operates in excess of 500 MHz, which is outside of its default operating limits. The CLKINx receiver actually consists of two separate receivers— the default receiver and an optional high frequency receiver, which handles input signals up to 800 MHz. To select the high frequency receiver, write a Logic 1 to Register 0x0400, Bit 4. Super-Nyquist operation requires a band-pass filter at the DAC output instead of the usual low-pass reconstruction filter. Each of the output channels offers independent control of power-down functionality via the distribution settings register (Address 0x0400). Each output channel has a dedicated powerdown bit for powering down the output driver. However, if all four outputs are powered down, the entire distribution output enters a deep sleep mode. Even though each channel has a channel power-down control signal, it may sometimes be desirable to power down an output driver while maintaining the divider’s synchronization with the other channel dividers. This is accomplished by either of the following methods: In CMOS mode, use the divider output enable control bit to stall an output. This provides power savings while maintaining dc drive at the output. In LVDS/LVPECL mode, place the output in tristate mode (this works in CMOS mode as well). Output Enable Each of the output channels offers independent control of enable/disable functionality via the distribution enable register (Address 0x0401). The distribution outputs use synchronization Rev. G | Page 40 of 111 Data Sheet AD9548 logic to control enable/disable activity to avoid the production of runt pulses and ensure that outputs with the same divide ratios become active/inactive in unison. Output Mode The user has independent control of the operating mode of each of the four output channels via the distribution channel modes register (Address 0x0404 to Address 0x0407). The operating mode control includes • • • Logic family and pin functionality Output drive strength Output polarity The three least significant bits of each of the four distribution channel mode registers comprise the mode bits. The mode value selects the desired logic family and pin functionality of an output channel, as given in Table 24. Table 24. Output Channel Logic Family and Pin Functionality Mode Bits [2:0] 000 001 010 011 100 101 110 111 Logic Family and Pin Functionality CMOS (both pins) CMOS (positive pin); tristate (negative pin) Tristate (positive pin); CMOS (negative pin) Tristate (both pins) LVDS LVPECL Unused Unused Regardless of the selected logic family, each is capable of dc operation. However, the upper frequency is limited by the load conditions, drive strength, and impedance matching inherent in each logic family. Practical limitations set the maximum CMOS frequency to approximately 250 MHz, whereas LVPECL and LVDS are capable of 725 MHz. In addition to the three mode bits, each of the four distribution channel mode registers includes the following control bits: • • • Polarity invert CMOS phase invert Drive strength weak setting implies low capacitive loading and allows for reduced EMI. For the LVDS family, the weak setting provides 3.5 mA drive current for standard LVDS operation, whereas the strong setting provides 7 mA for double terminated or double voltage LVDS operation. Note that 3.5 mA and 7 mA are the nominal drive current values when using the internal current setting resistor. Output Current Control with an External Resistor By default, the output drivers have an internal current setting resistor (3.12 kΩ nominal) that establishes the nominal drive current for the LVDS and LVPECL operating modes. Instead of using the internal resistor, the user can set the external distribution resistor bit (Register 0x0400, Bit 5) and connect an external resistor to the OUT_RSET pin. Note that this feature supports an external resistor value of 3.12 kΩ only, allowing for tighter control of the output current than is possible by using the internal current setting resistor. However, if the user elects to use a nonstandard external resistance, the following equations provide the output drive current as a function of the external resistance (R): I LVDS 0 = 10.8325 R I LVDS1 = 21.665 R I LVPECL = 24.76 R The numeric subscript associated with the LVDS output current corresponds to the logic state of the drive strength bit in the distribution channel modes register (Address 0x0404 to Address 0x00407). For R = 3.12 kΩ, the equations yield ILVDS0 = 3.5 mA, ILVDS1 = 7.0 mA, and ILVPECL = 8.0 mA. Note that the device maintains a constant 1.238 V (nominal) across the external resistor. Clock Distribution Synchronization A block diagram of the distribution synchronization functionality appears in Figure 50. The synchronization sequence begins with the primary synchronization signal, which ultimately results in delivery of a synchronization strobe to the clock distribution logic. The polarity invert bit enables the user to choose between normal polarity and inverted polarity. Normal polarity is the default state. Inverted polarity reverses the representation of Logic 0 and Logic 1 regardless of the logic family. As indicated, the primary synchronization signal originates from four possible sources. The CMOS phase invert bit applies only when the mode bits select the CMOS logic family. In CMOS mode, both output pins of the channel have a dedicated CMOS driver. By default, both drivers deliver identical signals. However, setting the CMOS phase invert bit causes the signal on an OUTxN pin to be the opposite of the signal appearing on the OUTxP pin. • The drive strength bit allows the user to control whether the output uses weak (0) or strong (1) drive capability (applies to CMOS and LVDS but not LVPECL). For the CMOS family, the strong setting implies normal CMOS drive capability, whereas the All four sources of the primary synchronization signal are logic OR’ed, so any one of them can synchronize the clock distribution output at any time. When using the multifunction pins, the synchronization event is the falling edge of the selected • • • Rev. G | Page 41 of 111 Direct sync source via the sync distribution bit (Register 0x0A02, Bit 1) Automatic sync source based on frequency or phase lock detection as controlled via the automatic synchronization register (Address 0x0403) Multifunction pin sync source via one of the multifunction pins (M0 to M7) EEPROM sync source via the EEPROM AD9548 Data Sheet signal. When using the sync distribution bit, the user sets and then clears the bit. The synchronization event is the clearing operation; that is, the Logic 1 to Logic 0 transition of the bit. The primary synchronization signal can synchronize the distribution output directly, or it can enable a secondary synchronization signal. This functionality depends on the two sync source bits in the distribution synchronization register (Register 0x0402, Bits[5:4]). When sync source = 00 (direct), the falling edge of the primary synchronization signal synchronizes the distribution output directly. When sync source = 01, the rising edge of the primary synchronization signal triggers the circuitry that detects a rising edge of the active input reference. The detection of the rising edge is what synchronizes the distribution output. When sync source = 10, the rising edge of the primary synchronization signal triggers the circuitry that detects a rollover of the DDS accumulator (after processing by the DPLL feedback divider). This corresponds to the zero crossing of the output of the phase-to-amplitude converter in the DDS (less the open-loop phase offset stored in Register 0x030D to Register 0x030E). The detection of the DPLL feedback edge is what synchronizes the distribution output. The term zero delay applies because it provides a means to edge align the output signal with the active input reference signal. Typically, zero-delay architectures use the output signal in the feedback loop of a PLL to track input/output edge alignment. Active reference synchronization, however, operates open-loop. That is, synchronization of the output via the distribution synchronization logic occurs on a single edge of the active reference. The fact that an active reference edge triggers the falling edge of the synchronization pulse means that the falling edge is asynchronous to the signal that clocks the distribution output dividers (CLKINx). Therefore, the output clock distribution logic reclocks the internal synchronization pulse to synchronize it with the CLKINx signal. This means that the output dividers restart after a deterministic delay associated with the reclocking circuitry. This deterministic delay has two components. The first deterministic delay component is four or five periods of the CLKINx signal. The one period uncertainty is due to the unknown position of the asynchronous reference clock edge relative to the CLKINx signal. The second deterministic delay component is one output period of the distribution divider. Active Reference Synchronization (Zero Delay) Active reference synchronization is the term applied to the case when sync source = 01 (Register 0x0402, Bits[5:4]). Referring to Figure 50, this means that the active reference sync path is active because Bit 4 = 1, enabling the lower AND gate and disabling the upper AND gate. The edge detector in the active reference sync block monitors the rising edges of the active reference (the mux selects the active reference automatically). The edge detector is armed via the primary synchronization signal, which is one of the four inputs to the OR gate (typically the direct sync source). As soon as the edge detector is armed, its output goes high, which stalls the output dividers in the clock distribution block. Furthermore, once armed, a rising edge from the active reference forces the output of the edge detector low. This restarts the output dividers, thereby synchronizing the clock distribution block. Rev. G | Page 42 of 111 Data Sheet DIRECT SYNC SOURCE (REGISTER 0A02[1]) AD9548 REGISTER 0402[5] PRIMARY SYNCHRONIZATION SIGNAL DIRECT SYNC AUTOMATIC SYNC SOURCE (REGISTER 0403) EEPROM SYNC SOURCE 0 TO CLOCK DISTRIBUTION SYNCHRONIZATION CONTROL 1 EDGE DETECT MULTIFUNCTION PIN SYNC SOURCE TO MULTIFUNCTION PIN STATUS LOGIC DPLL FEEDBACK EDGE ARM STALL DIVIDERS SYNC OUTPUT DISTRIBUTION EDGE DETECT SYSCLK/4 DPLL EDGE SYNC REGISTER 0402[4] RESET ARM REF A REF AA EDGE DETECT ACTIVE REFERENCE SYNC 08022-023 REF D REF DD Figure 50. Output Synchronization Block Diagram The deterministic delay, expressed as tLATENCY in the following equations is a function of the frequency division factor (Qn) of the channel divider associated with the zero-delay channel. tLATENCY = (Qn + 4) × tCLK_IN or tLATENCY = (Qn + 5) × tCLK_IN In addition to deterministic delay, there is random delay (tPROP) associated with the propagation of the reference signal through the input reference receiver, as well as the propagation of the clock signal through the clock distribution logic. The total delay is tDELAY = tLATENCY + tPROP The user can compensate for tDELAY by using the phase offset controls of the device to move the edge timing of the distribution output signal relative to the input reference edge. One method is to use the open-loop phase offset registers (Address 030D to Address 030E) for timing adjustment. However, be sure to use sufficiently small phase increments to make the adjustment. Too large a phase step can result in the clock distribution logic missing a CLKINx edge, thus ruining the edge alignment process. The appropriate phase increment depends on the transient response of any external circuitry connected between the DACOUTx and CLKINx pins. The other method is to use the closed-loop phase offset registers (Address 0x030F to Address 0x0315) for timing adjustment. However, be sure to use a sufficiently small phase vs. time profile. Changing the phase too quickly can cause the DPLL to lose lock, thus ruining the edge alignment process. The AD9548 phase slew limit register (Address 0x0316 to Address 0x0317) can be used to limit the rate of change of phase automatically, thereby mitigating the potential loss-of-lock problem. To guarantee synchronization of the output dividers, it is important to make any edge timing adjustments after the synchronization event. Furthermore, when making timing adjustments, the distribution outputs can be disabled and then enabled after the adjustment is complete. This prevents the device from generating output clock signals during the timing adjustment process. Note that the form of zero-delay synchronization described here does not track propagation time variations within the distribution clock input path or the reference input path (on or off chip) over temperature, supply, and so on. It is strictly a one-time synchronization event. Synchronization Mask Each output channel has dedicated synchronization mask bits (Register 0x0402, Bits[3:0]). When the mask bit associated with a particular channel is set, then that channel does not respond to the synchronization signal. This allows the device to operate with the masked channels active and the unmasked channels stalled while they wait for a synchronization pulse. Rev. G | Page 43 of 111 AD9548 Data Sheet STATUS AND CONTROL MULTIFUNCTION PINS (M0 TO M7) The AD9548 has eight digital CMOS input/output pins (M0 to M7) that are configurable for a variety of uses. The function of these pins is programmable via the register map. Each pin can control or monitor an assortment of internal functions based on the contents of Register 0x0200 to Register 0x0207. To monitor an internal function with a multifunction pin, write a Logic 1 to the most significant bit of the register associated with the desired multifunction pin. The value of the seven least significant bits of the register defines the control function, as shown in Table 25. Table 25. Multifunction Pin Output Functions, Register 0x0200 to Register 0x0207 (Bit 7 = 1) Bits[6:0] Value 0 1 2 3 4 5 6 7 8 9 10 11 12 to 15 16 17 18 19 20 21 22 23 24 25 26 27 to 31 32 33 34 Output Function Static Logic 0 Static Logic 1 System clock divided by 32 Watchdog timer output EEPROM upload in progress EEPROM download in progress EEPROM fault detected SYSCLK PLL lock detected SYSCLK PLL calibration in progress Unused Unused SYSCLK PLL stable Unused DPLL free running DPLL active DPLL in holdover DPLL in reference switchover Active reference: phase master DPLL phase locked DPLL frequency locked DPLL phase slew limited DPLL frequency clamped Tuning word history available Tuning word history updated Unused Reference A fault Reference AA fault Reference B fault Source Proxy Bits[6:0] Value 35 36 37 38 39 40 to 47 48 49 50 51 52 53 54 55 56 to 63 64 65 Register 0x0D00, Bit 0 66 Register 0x0D00, Bit 1 67 Register 0x0D00, Bit 2 Register 0x0D01, Bit 0 68 69 Register 0x0D01, Bit 1 70 71 Register 0x0D01, Bit 4 Register 0x0D0A, Bit 0 Register 0x0D0A, Bit 1 Register 0x0D0A, Bit 2 Register 0x0D0A, Bit 3 72 to 79 80 81 to 127 Register 0x0D0A, Bit 6 Register 0x0D0A, Bit 4 Register 0x0D0A, Bit 5 Register 0x0D0A, Bit 7 Register 0x0D0B, Bit 7 Register 0x0D0B, Bit 6 Register 0x0D05, Bit 4 Register 0x0D0C, Bit 2 Register 0x0D0D, Bit 2 Register0x0D0E, Bit 2 Rev. G | Page 44 of 111 Output Function Reference BB fault Reference C fault Reference CC fault Reference D fault Reference DD fault Unused Reference A valid Reference AA valid Reference B valid Reference BB valid Reference C valid Reference CC valid Reference D valid Reference DD valid Unused Reference A active reference Reference AA active reference Reference B active reference Reference BB active reference Reference C active reference Reference CC active reference Reference D active reference Reference DD active reference Unused Clock distribution sync pulse Unused Source Proxy Register 0x0D0F, Bit 2 Register 0x0D10, Bit 2 Register 0x0D11, Bit 2 Register 0x0D12, Bit 2 Register 0x0D13, Bit 2 Register 0x0D0C, Bit 3 Register 0x0D0D, Bit 3 Register 0x0D0E, Bit 3 Register 0x0D0F, Bit 3 Register 0x0D10, Bit 3 Register 0x0D11, Bit 3 Register 0x0D12, Bit 3 Register 0x0D13, Bit 3 Register 0x0D0B, Bits[2:0] Register0x0D0B, Bits[2:0] Register 0x0D0B, Bits[2:0] Register 0x0D0B, Bits[2:0] Register 0x0D0B, Bits[2:0] Register 0x0D0B, Bits[2:0] Register 0x0D0B, Bits[2:0] Register 0x0D0B, Bits[2:0] Register 0x0D03, Bit 3 Data Sheet AD9548 To control an internal function with a multifunction pin, write a Logic 0 to the most significant bit of the register associated with the desired multifunction pin. The monitored function depends on the value of the seven least significant bits of the register, as shown in Table 26. Table 26. Multifunction Pin Input Functions, Register 0x0200 to Register 0x0207 (Bit 7 = 0) Bits[6:0] Value 0 1 2 3 4 5 6 to 15 16 17 18 19 20 21 to 31 32 33 34 35 36 37 38 39 40 to 47 48 49 50 51 52 53 54 55 56 to 63 64 65 66 67 68 69 70 to 127 Output Function Unused (default) I/O update Full power-down Watchdog reset IRQ reset Tuning word history reset Unused Holdover Free run Reset incremental phase offset Increment incremental phase offset Decrement incremental phase offset Unused Override Reference Monitor A Override Reference Monitor AA Override Reference Monitor B Override Reference Monitor BB Override Reference Monitor C Override Reference Monitor CC Override Reference Monitor D Override Reference Monitor DD Unused Force validation Timeout A Force validation Timeout AA Force validation Timeout B Force validation Timeout BB Force validation Timeout C Force validation Timeout CC Force validation Timeout D Force validation Timeout DD Unused Enable OUT0 Enable OUT1 Enable OUT2 Enable OUT3 Enable OUT0, OUT1, OUT2, OUT3 Sync clock distribution outputs Unused Destination Proxy Register 0x0005, Bit 0 Register 0x0A00, Bit 0 Register 0x0A03, Bit 0 Register 0x0A03, Bit 1 Register 0x0A03, Bit 2 Register 0x0A01, Bit 6 Register 0x0A01, Bit 5 Register 0x0A0C, Bit 2 Register 0x0A0C, Bit 0 Register 0x0A0C, Bit 1 Register 0x0A0F, Bit 0 Register 0x0A0F, Bit 1 Register 0x0A0F, Bit 2 Register 0x0A0F, Bit 3 Register 0x0A0F, Bit 4 Register 0x0A0F, Bit 5 Register 0x0A0F, Bit 6 Register 0x0A0F, Bit 7 Register 0x0A0E, Bit 0 Register 0x0A0E, Bit 1 Register 0x0A0E, Bit 2 Register 0x0A0E, Bit 3 Register 0x0A0E, Bit 4 Register 0x0A0E, Bit 5 Register 0x0A0E, Bit 6 Register 0x0A0E, Bit 7 Register 0x0401, Bit 0 Register 0x0401, Bit 1 Register 0x0401, Bit 2 Register 0x0401, Bit 3 Register 0x0401, Bits[3:0] Register 0x0A02, Bit 1 If more than one multifunction pin operates on the same control signal, then internal priority logic ensures that only one multifunction pin serves as the signal source. The selected pin is the one with the lowest numeric suffix. For example, if both M3 and M7 operate on the same control signal, then M3 is used as the signal source and the redundant pins are ignored. At power-up, the multifunction pins can be used to force the device into certain configurations as defined in the initial pin programming section. This functionality, however, is valid only during power-up or following a reset, after which the pins can be reconfigured via the serial programming port or via the EEPROM. IRQ PIN The AD9548 has a dedicated interrupt request (IRQ) pin. The IRQ pin output mode register (Register 0x0208, Bits[1:0]) controls how the IRQ pin asserts an interrupt based on the value of the two bits, as follows: 00—The IRQ pin is high impedance when deasserted and active low when asserted and requires an external pull-up resistor (this is the default operating mode). 01—The IRQ pin is high impedance when deasserted and active high when asserted and requires an external pull-down resistor. 10—The IRQ pin is Logic 0 when deasserted and Logic 1 when asserted. 11—The IRQ pin is Logic 1 when deasserted and Logic 0 when asserted. The AD9548 asserts the IRQ pin whenever any of the bits in the IRQ monitor register (Address 0x0D02 to Address 0x0D09) are Logic 1. Each bit in this register is associated with an internal function capable of producing an interrupt. Furthermore, each bit of the IRQ monitor register is the result of a logical AND of the associated internal interrupt signal and the corresponding bit in the IRQ mask register (Address 0x0209 to Address 0x0210). That is, the bits in the IRQ mask register have a oneto-one correspondence with the bits in the IRQ monitor register. Whenever an internal function produces an interrupt signal and the associated IRQ mask bit is set, then the corresponding bit in the IRQ monitor register is set. The user should be aware that clearing a bit in the IRQ mask register removes only the mask associated with the internal interrupt signal. It does not clear the corresponding bit in the IRQ monitor register. The IRQ pin is the result of a logical OR of all the IRQ monitor register bits. Thus, the AD9548 asserts the IRQ pin so long as any of the IRQ monitor register bits are Logic 1. Note that it is possible to have multiple bits set in the IRQ monitor register. Therefore, when the AD9548 asserts the IRQ pin, it may indicate an interrupt from several different internal functions. The IRQ monitor register provides the user with a means to interrogate the AD9548 to determine which internal function(s) produced the interrupt. Rev. G | Page 45 of 111 AD9548 Data Sheet The watchdog timer is a general-purpose programmable timer. To set the timeout period, the user writes to the 16-bit watchdog timer register (Address 0x0211 to Address 0x0212). A value of 0 in this register disables the timer. A nonzero value sets the timeout period in milliseconds, giving the watchdog timer a range of 1 ms to 65.535 sec. The relative accuracy of the timer is approximately 0.1% with an uncertainty of 0.5 ms. The EEPROM provides the ability to upload and download configuration settings to and from the register map. Figure 51 shows a functional diagram of the EEPROM. Register 0x0E10 to Register 0x0E3F represent a 48-byte scratch pad that enables the user to store a sequence of instructions for transferring data to the EEPROM from the device settings portion of the register map. Note that the default values for these registers provide a sample sequence for saving/retrieving all of the AD9548 EEPROM-accessible registers. Figure 51 shows the connectivity between the EEPROM and the controller that manages data transfer between the EEPROM and the register map. The controller oversees the process of transferring EEPROM data to and from the register map. There are two modes of operation handled by the controller—saving data to the EEPROM (upload mode) or retrieving data from the EEPROM (download mode). In either case, the controller relies on a specific instruction set. DATA M7 M6 M5 M4 M3 DEVICE SETTINGS ADDRESS POINTER If enabled, the timer runs continuously and generates a timeout event whenever the timeout period expires. The user has access to the watchdog timer status via the IRQ mechanism and the multifunction pins (M0 to M7). In the case of the multifunction pins, the timeout event of the watchdog timer is a pulse that lasts 32 system clock periods. There are two ways to reset the watchdog timer (thereby preventing it from causing a timeout event). The first is by writing a Logic 1 to the autoclearing reset watchdog bit in the reset function register (Register 0x0A03, Bit 0). Alternatively, the user can program any of the multifunction pins to reset the watchdog timer. This allows the user to reset the timer by means of a hardware pin rather than by a serial input/output port operation. Rev. G | Page 46 of 111 EEPROM ADDRESS POINTER EEPROM CONTROLLER DEVICE SETTINGS (0100 TO 0A10) EEPROM (000 TO 7FF) SCRATCH PAD ADDRESS POINTER SCRATCH PAD (0E10 TO 0E3F) REGISTER MAP SERIAL INPUT/OUTPUT PORT Figure 51. EEPROM Functional Diagram 08022-024 WATCHDOG TIMER The AD9548 contains an integrated 2048-byte, electronically erasable, programmable read-only memory (EEPROM). The AD9548 can be configured to perform a download at power-up via the multifunction pins (M3 to M7), but uploads and downloads can also be done on demand via the EEPROM control register (Address 0x0E00 to Address 0x0E03). DATA Note that the IRQ function detects a state change in the function that is being monitored. However, if IRQs are cleared (or if they are enabled for the first time), an IRQ will not be generated for a pre-existing condition. The state must change after the IRQ is enabled. For example, if REFA is already invalid before a “REFA invalid” IRQ is enabled, an IRQ will not be generated. EEPROM Overview CONDITION (0E01 [4:0]) It is also possible to collectively clear all of the IRQ monitor register bits by setting the reset all IRQs bit in the reset function register (Register 0x0A03, Bit 1). Note that this is an autoclearing bit. Setting this bit results in deassertion of the IRQ pin. Alternatively, the user can program any of the multifunction pins to clear all IRQs. This allows the user to clear all IRQs by means of a hardware pin rather than by a serial input/output port operation. EEPROM DATA Typically, when the AD9548 asserts the IRQ pin, the user interrogates the IRQ monitor register to identify the source of the interrupt request. After servicing an indicated interrupt, the user should clear the associated IRQ monitor register bit via the IRQ clearing register (Address 0x0A04 to Address 0x0A0B). The bits in the IRQ clearing register have a one-to-one correspondence with the bits in the IRQ monitor register. Note that the IRQ clearing register is autoclearing. The IRQ pin remains asserted until the user clears all of the bits in the IRQ monitor register that indicate an interrupt. Data Sheet AD9548 Table 27. EEPROM Controller Instruction Set Instruction Value (Hex) 0x00 to 0x7F Instruction Type Data Bytes Required 3 0x80 I/O update 1 0xA0 Calibrate 1 0xA1 Distribution sync 1 0xB0 to 0xCF Condition 1 0xFE Pause 1 0xFF End 1 Description A data instruction tells the controller to transfer data to or from the device settings part of the register map. A data instruction requires two additional bytes that together indicate a starting address in the register map. Encoded in the data instruction is the number of bytes to transfer, which is one more than the instruction value. When the controller encounters this instruction while downloading from the EEPROM, it issues a soft I/O update (see Register 0x0005 in Table 42). When the controller encounters this instruction while downloading from the EEPROM, it initiates a system clock calibration sequence (see Register 0x0A02 in Table 121). When the controller encounters this instruction while downloading from the EEPROM, it issues a sync pulse to the output distribution synchronization (see Register 0x0A02 in Table 121). 0xB1 to 0xCF are condition instructions and correspond to Condition 1 through Condition 31, respectively. 0xB0 is the null condition instruction. See the EEPROM Conditional Processing section for details. When the controller encounters this instruction in the scratch pad while uploading to the EEPROM, it resets the scratch pad address pointer and holds the EEPROM address pointer at its last value. This allows storage of more than one instruction sequence in the EEPROM. Note that the controller does not copy this instruction to the EEPROM during upload. When the controller encounters this instruction in the scratch pad while uploading to the EEPROM, it resets both the scratch pad address pointer and the EEPROM address pointer and then enters an idle state. When the controller encounters this instruction while downloading from the EEPROM, it resets the EEPROM address pointer and then enters an idle state. EEPROM Instructions Table 27 lists the EEPROM controller instruction set. The controller recognizes all instruction types whether it is in upload or download mode, except for the pause instruction, which it only recognizes in upload mode. The input/output update, calibrate, distribution sync, and end instructions are mostly self-explanatory. The others, however, warrant further detail, as described in the following paragraphs. Data instructions are those that have a value from 0x00 to 0x7F. A data instruction tells the controller to transfer data between the EEPROM and the register map. The controller needs the following two parameters to carry out the data transfer: The number of bytes to transfer The register map target address The controller decodes the number of bytes to transfer directly from the data instruction itself by adding one to the value of the instruction. For example, the data instruction, 1A, has a decimal value of 26; therefore, the controller knows to transfer 27 bytes (one more than the value of the instruction). Whenever the controller encounters a data instruction, it knows to read the next two bytes in the scratch pad because these contain the register map target address. Note that, in the EEPROM scratch pad, the two registers that comprise the address portion of a data instruction have the MSB of the address in the D7 position of the lower register address. The bit weight increases left to right, from the lower register address to the higher register address. Furthermore, the starting address always indicates the lowest numbered register map address in the range of bytes to transfer. That is, the controller always starts at the register map target address and counts upward regardless of whether the serial input/output port is operating in I2C, SPI LSB-first, or SPI MSB-first mode. As part of the data transfer process during an EEPROM upload, the controller calculates a 1-byte checksum and stores it as the final byte of the data transfer. As part of the data transfer process during an EEPROM download, however, the controller again calculates a 1-byte checksum value but compares the newly calculated checksum with the one that was stored during the upload process. If an upload/download checksum pair does not match, the controller sets the EEPROM fault status bit. If the upload/download checksums match for all data instructions encountered during a download sequence, the controller sets the EEPROM complete status bit. Condition instructions are those that have a value from 0xB0 to 0xCF. Condition instructions 0xB1 to 0xCF represent Condition 1 to Condition 31, respectively. The 0xB0 condition instruction is special because it represents the null condition (see the EEPROM Conditional Processing section). A pause instruction, like an end instruction, is stored at the end of a sequence of instructions in the scratch pad. When the controller encounters a pause instruction during an upload sequence, it keeps the EEPROM address pointer at its last value. This way the user can store a new instruction sequence in the scratch pad and upload the new sequence to the EEPROM. The new sequence is stored in the EEPROM address locations immediately following the previously saved sequence. This Rev. G | Page 47 of 111 AD9548 Data Sheet process is repeatable until an upload sequence contains an end instruction. The pause instruction is also useful when used in conjunction with condition processing. It allows the EEPROM to contain multiple occurrences of the same register(s), with each occurrence linked to a set of conditions (see the EEPROM Conditional Processing section). EEPROM Upload To upload data to the EEPROM, first ensure that the write enable bit (Register 0x0E00, Bit 0) is set. Then, on setting the autoclearing save to EEPROM bit (Register 0x0E02, Bit 0), the controller initiates the EEPROM data storage process. When an EEPROM save/load transfer is complete, wait a minimum of 10 μs before starting the next EEPROM save/load transfer. Uploading EEPROM data requires that the user first write an instruction sequence into the scratch pad registers. During the upload process, the controller reads the scratch pad data byte by byte, starting at Register 0x0E10 and incrementing the scratch pad address pointer as it goes until it reaches a pause or end instruction. Note that conditional processing does not occur during an upload sequence. (see the EEPROM Conditional Processing section). EEPROM Download An EEPROM download results in data transfer from the EEPROM to the device register map. To download data, the user sets the autoclearing load from the EEPROM bit (Register 0x0E03, Bit 1). This commands the controller to initiate the EEPROM download process. During download, the controller reads the EEPROM data byte by byte, incrementing the EEPROM address pointer as it goes, until it reaches an end instruction. As the controller reads the EEPROM data, it executes the stored instructions, which include transferring stored data to the device settings portion of the register map whenever it encounters a data instruction. When an EEPROM save/load transfer is complete, wait a minimum of 10 μs before starting the next EEPROM save/load transfer. Note that conditional processing is applicable only when downloading (see the EEPROM Conditional Processing section). Automatic EEPROM Download As the controller reads the scratch pad data, it transfers the data from the scratch pad to the EEPROM (byte by byte) and increments the EEPROM address pointer accordingly, unless it encounters a data instruction. A data instruction tells the controller to transfer data from the device settings portion of the register map to the EEPROM. The number of bytes to transfer is encoded within the data instruction, and the starting address for the transfer appears in the next two bytes in the scratch pad. Following a power-up, an assertion of the RESET pin, or a soft reset (Register 0x0000, Bit 5 = 1), if FncInit[7:3] ≠ 0 (see the Initial M0 to M7 Pin Programming section), then the instruction sequence stored in the EEPROM executes automatically with condition = FncInit[7:3]. In this way, a previously stored set of register values downloads automatically on power-up or with a hard or soft reset. See the EEPROM Conditional Processing section for details regarding conditional processing and the way it modifies the download process. When the controller encounters a data instruction, it stores the instruction in the EEPROM, increments the EEPROM address pointer, decodes the number of bytes to be transferred, and increments the scratch pad address pointer. Then it retrieves the next two bytes from the scratch pad (the target address) and increments the scratch pad address pointer by 2. Next, the controller transfers the specified number of bytes from the register map (beginning at the target address) to the EEPROM. Disabling Accidental Automatic EEPROM Download When it completes the data transfer, the controller stores an extra byte in the EEPROM to serve as a checksum for the transferred block of data. To account for the checksum byte, the controller increments the EEPROM address pointer by one more than the number of bytes transferred. Note that, when the controller transfers data associated with an active register, it actually transfers the buffered contents of the register (see the Buffered/Active Registers section for details on the difference between buffered and active registers). This allows for the transfer of nonzero autoclearing register contents. EEPROM Conditional Processing It is possible to bypass EEPROM downloading when M3 to M7 are either accidentally left floating or are pulled high. The following steps ensure that EEPROM loading is bypassed: 1. Register 0x0E10 = 0xFF (end of data). 2. Register 0x0E00 = 0x01 (EEPROM write enable). 3. Register 0x0E02 = 0x01 (save to EEPROM). 4. Wait until Register 0xD00 equals 0x00. The condition instructions allow conditional execution of EEPROM instructions during a download sequence. During an upload sequence, however, they are stored as is and have no effect on the upload process. Note that, during EEPROM downloads, the condition instructions themselves and the end instruction always execute unconditionally. Conditional processing makes use of two elements: the condition (from Condition 1 to Condition 31) and the condition tag board. The relationships among the condition, the condition tag board, and the EEPROM controller appear schematically in Figure 52. Rev. G | Page 48 of 111 Data Sheet AD9548 CONDITION TAG BOARD EXAMPLE CONDITION 3 AND CONDITION 13 ARE TAGGED M7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 IF B1 ≤ INSTRUCTION ≤ CF, THEN TAG DECODED CONDITION IF INSTRUCTION = B0, THEN CLEAR ALL TAGS EEPROM UPLOAD PROCEDURE 5 5 IF {0E01, BITS[4:0] ≠ 0} CONDITION = 0E01, BITS[4:0] ELSE CONDITION = FncInit, BITS[7:3] ENDIF 5 COND ITION CONDITION HANDLER SCRATCH PAD FncInit, BITS[7:3] EXECUTE/SKIP INSTRUCTION(S) DOWNLOAD PROCEDURE IF {NO TAGS} OR {CONDITION = 0} EXECUTE INSTRUCTIONS ELSE IF {CONDITION IS TAGGED} EXECUTE INSTRUCTIONS ELSE SKIP INSTRUCTIONS ENDIF ENDIF 08022-025 STORE CONDITION INSTRUCTIONS AS THEY ARE READ FROM THE SCRATCH PAD. WATCH FOR OCCURRENCE OF CONDITION INSTRUCTIONS DURING DOWNLOAD. REGISTER 0E01, BITS[4:0] M3 EEPROM CONTROLLER Figure 52. EEPROM Conditional Processing The condition is a 5-bit value with 32 possibilities. Condition = 0 is the null condition. When the null condition is in effect, the EEPROM controller executes all instructions unconditionally. The remaining 31 possibilities, condition = 1 through condition = 31, modify the EEPROM controller’s handling of a download sequence. The condition originates from one of two sources (see Figure 52), as follows: FncInit, Bits[7:3], which is the state of the M3 to M7 multifunction pins at power-up (see the Initial M0 to M7 Pin Programming section) Register 0x0E01, Bits[4:0] If Register 0x0E01, Bits[4:0] ≠ 0, then the condition is the value stored in Register 0x0E01, Bits[4:0]; otherwise, the condition is FncInit, Bits[7:3]. Note that a nonzero condition present in Register 0x0E01, Bits[4:0] takes precedence over FncInit, Bits[7:3]. During download, the EEPROM controller executes or skips instructions depending on the value of condition and the contents of the condition tag board. Note, however, that condition instructions and the end instruction always execute unconditionally during download. If condition = 0, then all instructions during download execute unconditionally. If condition ≠ 0 and there are any tagged conditions in the condition tag board, then the controller executes instructions only if the condition is tagged. If the condition is not tagged, then the controller skips instructions until it encounters a condition instruction that decodes as a tagged condition. Note that the condition tag board allows for multiple conditions to be tagged at any given moment. This conditional processing mechanism enables the user to have one download instruction sequence with many possible outcomes depending on the value of the condition and the order in which the controller encounters condition instructions. The condition tag board is a table that is maintained by the EEPROM controller. When the controller encounters a condition instruction, it decodes the 0xB1 through 0xCF instructions as condition = 1 through condition = 31, respectively, and tags that particular condition in the condition tag board. However, the 0xB0 condition instruction decodes as the null condition, for which the controller clears the condition tag board, and subsequent download instructions execute unconditionally (until the controller encounters a new condition instruction). Rev. G | Page 49 of 111 AD9548 Data Sheet Table 28 lists a sample EEPROM download instruction sequence. It illustrates the use of condition instructions and how they alter the download sequence. The table begins with the assumption that no conditions are in effect. That is, the most recently executed condition instruction is 0xB0 or no conditional instructions have been processed. 1. 2. Table 28. EEPROM Conditional Processing Example 4. Instruction 0x08 0x01 0x00 0xB1 0x19 0x04 0x00 0xB2 0xB3 0x07 0x05 0x00 0x0A 0xB0 0x80 0x0A Action Transfer the system clock register contents regardless of the current condition. With the upload sequence written to the scratch pad, perform an EEPROM upload (Register 0x0E02, Bit 0). Tag Condition 1. Transfer the clock distribution register contents only if condition = 1. Repeat the process of programming the device control registers for a new setup, storing a new upload sequence in the EEPROM scratch pad (Step 1 through Step 4), and executing an EEPROM upload (Register 0x0E02, Bit 0) until all of the desired setups have been uploaded to the EEPROM. Tag Condition 2. Tag Condition 3. Transfer the reference input register contents only if condition = 1, 2, or 3. Note that, on the final upload sequence stored in the scratch pad, the pause instruction (FE) must be replaced with an end instruction (FF). Calibrate the system clock only if condition = 1, 2, or 3. Clear the condition tag board. Execute an I/O update regardless of the value of the condition. Calibrate the system clock regardless of the value of the condition. Storing Multiple Device Setups in EEPROM Conditional processing makes it possible to create a number of different device setups, store them in EEPROM, and download a specific setup on demand. To do so, first program the device control registers for a specific setup. Then, store an upload sequence in the EEPROM scratch pad with the following general form: 1. 2. 3. 3. Condition instruction (0xB0) The next desired condition instruction (0xB1 to 0xCF, but different than the one used during the previous upload to identify a new setup) Data instructions (to save the register contents) along with any required calibrate and/or input/output update instructions Pause instruction (FE) Condition instruction (0xB1 to 0xCF) to identify the setup with a specific condition (1 to 31) Data instructions (to save the register contents) along with any required calibrate and/or input/output update instructions Pause instruction (0xFE) With the upload sequence written to the scratch pad, perform an EEPROM upload (Register 0x0E02, Bit 0). Reprogram the device control registers for the next desired setup. Then store a new upload sequence in the EEPROM scratch pad with the following general form: To download a specific setup on demand, first store the condition associated with the desired setup in Register 0x0E01, Bits[4:0]. Then perform an EEPROM download (Register 0x0E03, Bit 1). Alternatively, to download a specific setup at power-up, apply the required logic levels necessary to encode the desired condition on the M3 to M7 multifunction pins. Then power up the device; an automatic EEPROM download occurs. The condition (as established by the M3 to M7 multifunction pins) guides the download sequence and results in a specific setup. Keep in mind that the number of setups that can be stored in the EEPROM is limited. The EEPROM can hold a total of 2048 bytes. Each nondata instruction requires one byte of storage. Each data instruction, however, requires N + 4 bytes of storage, where N is the number of transferred register bytes and the other four bytes include the data instruction itself (one byte), the target address (two bytes), and the checksum calculated by the EEPROM controller during the upload sequence (one byte). Programming the EEPROM to Include a Clock Part ID A special EEPROM loading sequence is required to use the clock part ID registers. These registers provide for part and revision identification. The default EEPROM loading sequence from Register 0x0E10 to Register 0x0E31 is unchanged. The following steps must be inserted into the EEPROM storage sequence to use the clock part ID registers: 1. 2. 3. 4. 5. Rev. G | Page 50 of 111 Register 0x0E32 = 0x07 (write 8 bytes) Register 0x0E33 = 0x0C (at Register 0x0C00) Register 0x0E34 = 0x00 Register 0x0E35 = 0x80 (input/output update) Register 0x0E36 = 0xFF (end of data) Data Sheet AD9548 SERIAL CONTROL PORT SCLK/SCL CS/SDA SDIO SDO 13-BIT ADDRESS SPACE SPI READ ONLY REGION 2 IC EEPROM POWER-ON RESET EEPROM CONTROLLER MULTIFUNCTION PIN CONTROL LOGIC READ/WRITE REGION ANALOG BLOCKS AND DIGITAL CORE 400kHz M7 M6 M5 M4 M3 M2 M1 M0 08022-026 SERIAL CONTROL ARBITER Figure 53. Serial Port Functional Diagram The AD9548 serial control port is a flexible, synchronous serial communications port that provides a convenient interface to many industry-standard microcontrollers and microprocessors. The AD9548 serial control port is compatible with most synchronous transfer formats, including Philips I2C, Motorola SPI, and Intel SSR protocols. The serial control port allows read/write access to the AD9548 register map. In SPI mode, single or multiple byte transfers are supported. The SPI port configuration is programmable via Register 0x0000. This register is integrated into the SPI control logic rather than in the register map and is distinct from the I2C Register 0x0000. It is also inaccessible to the EEPROM controller. (see Table 29). Note that the four MSBs of the slave address are hardware coded as 1011. Table 29. Serial Port Mode Selection M2 0 0 0 0 1 1 1 1 M1 0 0 1 1 0 0 1 1 M0 0 1 0 1 0 1 0 1 Serial Port Mode SPI I²C (address = 1001001) I²C (address = 1001010) I²C (address = 1001011) I²C (address = 1001100) I²C (address = 1001101) I²C (address = 1001110) I²C (address = 1001111) A functional diagram of the serial control port, including its relationship to the EEPROM, appears in Figure 53. SPI SERIAL PORT OPERATION Although the AD9548 supports both the SPI and I2C serial port protocols, only one is active following power-up (as determined by the multifunction pins, M0 to M2, during the startup sequence). That is, the only way to change the serial port protocol is to reset the device (or cycle the device power supply). Both protocols use a common set of control pins as shown in Figure 54. The SCLK (serial clock) pin serves as the serial shift clock. This pin is an input. SCLK synchronizes serial control port read and write operations. The rising edge SCLK registers write data bits, and the falling edge registers read data bits. The SCLK pin supports a maximum clock rate of 40 MHz. 2 AD9548 SDIO 3 SDO 4 SERIAL CONTROL PORT CSB/SDA 5 The SDIO (serial data input/output) pin is a dual-purpose pin and acts as either an input only (unidirectional mode) or as both an input and an output (bidirectional mode). The AD9548 default SPI mode is bidirectional. The SDO (serial data output) pin is useful only in unidirectional input/output mode. It serves as the data output pin for read operations. 08022-027 SCLK/SCL Pin Descriptions The CS (chip select) pin is an active low control that gates read and write operations. This pin is internally connected to a 30 kΩ pull-up resistor. When CS is high, the SDO and SDIO pins go into a high impedance state. Figure 54. Serial Control Port SPI/I²C PORT SELECTION Because the AD9548 supports both SPI and I2C protocols, the active serial port protocol depends on the logic state of the three multifunction pins, M0 to M2, at startup. If all three pins are set to Logic 0 at startup, then the SPI protocol is active. Otherwise, the I2C protocol is active with seven different I2C slave address settings based on the startup logic pattern on the M0 to M2 pins Rev. G | Page 51 of 111 AD9548 Data Sheet SPI Mode Operation Write The SPI port supports both 3-wire (bidirectional) and 4-wire (unidirectional) hardware configurations and both MSB-first and LSB-first data formats. Both the hardware configuration and data format features are programmable. By default, the AD9548 uses the bidirectional MSB-first mode. The reason that bidirectional is the default mode is so that the user can still write to the device, if it is wired for unidirectional operation, to switch to unidirectional mode. If the instruction word indicates a write operation, the payload is written into the serial control port buffer of the AD9548. Data bits are registered on the rising edge of SCLK. The length of the transfer (1, 2, or 3 bytes or streaming mode) depends on the W0 and W1 bits (see Table 30) in the instruction byte. When not streaming, CS can be deasserted after each sequence of eight bits to stall the bus (except after the last byte, where it ends the cycle). When the bus is stalled, the serial transfer resumes when CS is asserted. Deasserting the CS pin on a nonbyte boundary resets the serial control port. Reserved or blank registers are not skipped over automatically during a write sequence. Therefore, the user must know what bit pattern to write to the reserved registers to preserve proper operation of the part. Generally, it does not matter what data is written to blank registers, but it is customary to write 0s. Assertion (active low) of the CS pin initiates a write or read operation to the AD9548 SPI port. For data transfers of three bytes or fewer (excluding the instruction word), the device supports the CS stalled high mode (see Table 30). In this mode, the CS pin can be temporarily deasserted on any byte boundary, allowing time for the system controller to process the next byte. CS can be deasserted only on byte boundaries, however. This applies to both the instruction and data portions of the transfer. During stall high periods, the serial control port state machine enters a wait state until all data is sent. If the system controller decides to abort a transfer midstream, then the state machine must be reset by either completing the transfer or by asserting the CS pin for at least one complete SCLK cycle (but less than eight SCLK cycles). Deasserting the CS pin on a nonbyte boundary terminates the serial transfer and flushes the buffer. In the streaming mode (see Table 30), any number of data bytes can be transferred in a continuous stream. The register address is automatically incremented or decremented. CS must be deasserted at the end of the last byte transferred, thereby ending the stream mode. W0 0 1 0 1 Read The AD9548 supports the long instruction mode only. If the instruction word indicates a read operation, the next N × 8 SCLK cycles clock out the data from the address specified in the instruction word. N is the number of data bytes read and depends on the W0 and W1 bits of the instruction word. Table 30. Byte Transfer Count W1 0 0 1 1 Most of the serial port registers are buffered (see the Buffered/Active Registers section for details on the difference between buffered and active registers). Therefore, data written into buffered registers does not take effect immediately. An additional operation is needed to transfer buffered serial control port contents to the registers that actually control the device. This is accomplished with an input/output update operation, which is performed in one of two ways. One is by writing a Logic 1 to Register 0x0005, Bit 0 (this bit is self-clearing). The other is to use an external signal via an appropriately programmed multifunction pin. The user can change as many register bits as desired before executing an input/output update. The input/output update operation transfers the buffer register contents to their active register counterparts. Bytes to Transfer 1 2 3 Streaming mode Communication Cycle—Instruction Plus Data The SPI protocol consists of a two-part communication cycle. The first part is a 16-bit instruction word that is coincident with the first 16 SCLK rising edges and a payload. The instruction word provides the AD9548 serial control port with information regarding the payload. The instruction word includes the R/W bit that indicates the direction of the payload transfer (that is, a read or write operation). The instruction word also indicates the number of bytes in the payload and the starting register address of the first payload byte. During a SPI read, serial data on SDIO (or SDO in the case of 4-wire mode) transitions on the SCLK falling edge and is normally sampled on the SCLK rising edge. To read the last bit correctly, the SPI host must be able to tolerate a zero hold time. If zero hold time is not possible, the user can either use streaming mode and delay the rising edge of CS, or sample the serial data on the SCLK falling edge. However, to sample the data on the SCLK falling edge correctly, the user must ensure that the setup time is greater than tDV (time data valid). Blank registers are not skipped over during readback. A readback operation takes data from either the serial control port buffer registers or the active registers, as determined by Register 0x0004, Bit 0. Rev. G | Page 52 of 111 Data Sheet AD9548 SPI Instruction Word (16 Bits) includes the register address of the least significant payload byte followed by multiple data bytes. The serial control port internal byte address generator increments for each byte of the multibyte transfer cycle. The MSB of the 16-bit instruction word is R/W, which indicates whether the instruction is a read or a write. The next two bits, W1 and W0, indicate the number of bytes in the transfer (see Table 30). The final 13 bits are the register address (A12 to A0), which indicates the starting register address of the read/write operation (see Table 32). For multibyte MSB-first (default) input/output operations, the serial control port register address decrements from the specified starting address toward Address 0x0000. For multibyte LSB-first input/output operations, the serial control port register address increments from the starting address toward Address 0x1FFF. Unused addresses are not skipped during multibyte input/output operations; therefore, the user should write the default value to a reserved register and 0s to unmapped registers. Note that it is more efficient to issue a new write command than to write the default value to more than two consecutive reserved (or unmapped) registers. SPI MSB-/LSB-First Transfers The AD9548 instruction word and payload can be MSB-first or LSB-first. The default for the AD9548 is MSB-first. The LSB-first mode can be set by writing a 1 to Register 0x0000, Bit 6. Immediately after the LSB-first bit is set, subsequent serial control port operations are LSB-first. When MSB-first mode is active, the instruction and data bytes must be written from MSB to LSB. Multibyte data transfers in MSB-first format start with an instruction byte that includes the register address of the most significant payload byte. Subsequent data bytes must follow in order from high address to low address. In MSB-first mode, the serial control port internal address generator decrements for each data byte of the multibyte transfer cycle. Table 31. Streaming Mode (No Addresses Are Skipped) Write Mode LSB First MSB First Address Direction Increment Decrement Stop Sequence 0x0000 ... 0x1FFF 0x1FFF ... 0x0000 When Register 0x0000, Bit 6 = 1 (LSB-first), the instruction and data bytes must be written from LSB to MSB. Multibyte data transfers in LSB-first format start with an instruction byte that Table 32. Serial Control Port, 16-Bit Instruction Word, MSB-First MSB I15 I14 I13 I12 I11 I10 I9 I8 I7 I6 I5 I4 I3 I2 I1 LSB I0 R/W W1 W0 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 CS SCLK DON'T CARE R/W W1 W0 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 16-BIT INSTRUCTION HEADER D7 D6 D5 D4 D3 D2 D1 REGISTER (N) DATA D0 D7 D6 D5 D4 D3 D2 D1 D0 DON'T CARE REGISTER (N – 1) DATA 08022-029 SDIO DON'T CARE DON'T CARE Figure 55. Serial Control Port Write—MSB-First, 16-Bit Instruction, Two Bytes of Data CS SCLK DON'T CARE R/W W1 W0 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 SDO DON'T CARE D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 16-BIT INSTRUCTION HEADER REGISTER (N) DATA REGISTER (N – 1) DATA REGISTER (N – 2) DATA Figure 56. Serial Control Port Read—MSB-First, 16-Bit Instruction, Four Bytes of Data Rev. G | Page 53 of 111 REGISTER (N – 3) DATA DON'T CARE 08022-030 SDIO DON'T CARE AD9548 Data Sheet tDS tHIGH tDH SCLK DON'T CARE SDIO DON'T CARE R/W W1 tC tCLK tLOW CS W0 A12 A11 A10 A9 A8 A7 A6 A5 D4 D3 D2 D1 D0 HIGH-IMEPDANCE 08022-153 tS Figure 57. Serial Control Port Read—MSB-First, 16-Bit Instruction, One Byte of Data tDS tHI tS CS DON'T CARE SDIO DON'T CARE tLO DON'T CARE R/W W1 W0 A12 A11 A10 A9 A8 A7 A6 A5 D4 D3 D2 D1 D0 DON'T CARE 08022-031 SCLK tC tCLK tDH Figure 58. Serial Control Port Write—MSB-First, 16-Bit Instruction, Timing Measurements CS SCLK DATA BIT N 08022-032 tDV SDIO SDO DATA BIT N – 1 Figure 59. Timing Diagram for Serial Control Port Register Read CS SCLK DON'T CARE DON'T CARE A4 A5 A6 A7 A8 A9 A10 A11 A12 W0 W1 R/W D0 D1 D2 D3 D4 16-BIT INSTRUCTION HEADER D5 D6 REGISTER (N) DATA D7 D0 D1 D2 D3 D4 D5 D6 D7 REGISTER (N + 1) DATA Figure 60. Serial Control Port Write—LSB-First, 16-Bit Instruction, Two Bytes of Data CS tS tC tCLK tHI tLO tDS SCLK tDH SDIO BIT N BIT N + 1 Figure 61. Serial Control Port Timing—Write Rev. G | Page 54 of 111 DON'T CARE 08022-033 A0 A1 A2 A3 08022-034 SDIO DON'T CARE Data Sheet AD9548 Table 33. Serial Control Port Timing Parameter tDS tDH tCLK tS tC tHI tLO tDV Description Setup time between data and the rising edge of SCLK. Hold time between data and the rising edge of SCLK. Period of the clock. Setup time between the CS falling edge and the SCLK rising edge (start of the communication cycle). Setup time between the SCLK rising edge and the CS rising edge (end of the communication cycle). To ensure that SDIO/SDO do not tristate before the last data bit (D0) is read, it is recommended that a ½ SCLK cycle be used for tC. Minimum period that SCLK should be in a logic high state. Minimum period that SCLK should be in a logic low state. SCLK to valid SDIO and SDO (see Figure 59). Rev. G | Page 55 of 111 AD9548 Data Sheet I²C SERIAL PORT OPERATION I2C Bus Characteristics The I2C interface has the advantage of requiring only two control pins and is a de facto standard throughout the I2C industry. However, its disadvantage is programming speed, which is 400 kbps maximum. The AD9548 I2C port design is based on the I2C fast mode standard from Philips, so it supports both the 100 kHz standard mode and 400 kHz fast mode. Fast mode imposes a glitch tolerance requirement on the control signals. That is, the input receivers ignore pulses of less than 50 ns duration. A summary of the various I2C protocols appears in Table 34. Table 34. I2C Bus Abbreviation Definitions Abbreviation S Sr P A A W R The AD9548 I2C port consists of a serial data line (SDA) and a serial clock line (SCL). In an I2C bus system, the AD9548 is connected to the serial bus (data bus SDA and clock bus SCL) as a slave device; that is, no clock is generated by the AD9548. The AD9548 uses direct 16-bit memory addressing instead of traditional 8-bit memory addressing. Definition Start Repeated start Stop Acknowledge Nonacknowledge Write Read The transfer of data is shown in Figure 62. One clock pulse is generated for each data bit transferred. The data on the SDA line must be stable during the high period of the clock. The high or low state of the data line can only change when the clock signal on the SCL line is low. The AD9548 allows up to seven unique slave devices to occupy the I2C bus. These are accessed via a 7-bit slave address transmitted as part of an I2C packet. Only the device with a matching slave address responds to subsequent I2C commands. The device slave address is 1001xxx (the three right bits are determined by the M0 to M2 pins). The four MSBs (1001) are hardwired, while the three LSBs (xxx, determined by the M0 to M2 pins) are programmable via the power-up state of the multifunction pins (see the Initial M0 to M7 Pin Programming section). SDA SCL CHANGE OF DATA ALLOWED 08022-035 DATA LINE STABLE; DATA VALID Figure 62. Valid Bit Transfer Start/stop functionality is shown in Figure 63. The start condition is characterized by a high-to-low transition on the SDA line while SCL is high. The start condition is always generated by the master to initialize a data transfer. The stop condition is characterized by a low-to-high transition on the SDA line while SCL is high. The stop condition is always generated by the master to terminate a data transfer. Every byte on the SDA line must be eight bits long. Each byte must be followed by an acknowledge bit; bytes are sent MSB first. SDA SCL S START CONDITION 08022-036 P STOP CONDITION Figure 63. Start and Stop Conditions MSB ACK FROM SLAVE-RECEIVER 1 SCL 2 3 TO 7 8 9 ACK FROM SLAVE-RECEIVER 1 S Figure 64. Acknowledge Bit Rev. G | Page 56 of 111 2 3 TO 7 8 9 10 P 08022-037 SDA Data Sheet AD9548 The acknowledge bit (A) is the ninth bit attached to any 8-bit data byte. An acknowledge bit is always generated by the receiving device (receiver) to inform the transmitter that the byte has been received. It is done by pulling the SDA line low during the ninth clock pulse after each 8-bit data byte. Data is then sent over the serial bus in the format of nine clock pulses, one data byte (eight bits) from either master (write mode) or slave (read mode) followed by an acknowledge bit from the receiving device. The number of bytes that can be transmitted per transfer is unrestricted. In write mode, the first two data bytes immediately after the slave address byte are the internal memory (control registers) address bytes, with the high address byte first. This addressing scheme gives a memory address of up to 216 − 1 = 65,535. The data bytes after these two memory address bytes are register data written to or read from the control registers. In read mode, the data bytes after the slave address byte are register data written to or read from the control registers. The nonacknowledge bit (A) is the ninth bit attached to any 8-bit data byte. A nonacknowledge bit is always generated by the receiving device (receiver) to inform the transmitter that the byte has not been received. It is done by leaving the SDA line high during the ninth clock pulse after each 8-bit data byte. Data Transfer Process The master initiates data transfer by asserting a start condition. This indicates that a data stream follows. All I2C slave devices connected to the serial bus respond to the start condition. When all data bytes are read or written, stop conditions are established. In write mode, the master (transmitter) asserts a stop condition to end data transfer during the 10th clock pulse following the acknowledge bit for the last data byte from the slave device (receiver). In read mode, the master device (receiver) receives the last data byte from the slave device (transmitter) but does not pull SDA low during the ninth clock pulse. This is known as a nonacknowledge bit. By receiving the nonacknowledge bit, the slave device knows the data transfer is finished and enters idle mode. The master then takes the data line low during the low period before the 10th clock pulse, and high during the 10th clock pulse to assert a stop condition. The master then sends an 8-bit address byte over the SDA line, consisting of a 7-bit slave address (MSB first) plus an R/W bit. This bit determines the direction of the data transfer, that is, whether data is written to or read from the slave device (0 = write, 1 = read). The peripheral whose address corresponds to the transmitted address responds by sending an acknowledge bit. All other devices on the bus remain idle while the selected device waits for data to be read from or written to it. If the R/W bit is 0, the master (transmitter) writes to the slave device (receiver). If the R/W bit is 1, the master (receiver) reads from the slave device (transmitter). A start condition can be used in place of a stop condition. Furthermore, a start or stop condition can occur at any time, and partially transferred bytes are discarded. The format for these commands is described in the Data Transfer Format section. MSB ACK FROM SLAVE-RECEIVER 1 SCL 2 3 TO 7 8 9 ACK FROM SLAVE-RECEIVER 1 2 3 TO 7 8 9 S 10 P 08022-038 SDA Figure 65. Data Transfer Process (Master Write Mode, 2-Byte Transfer) SDA ACK FROM MASTER-RECEIVER 1 2 3 TO 7 8 9 1 2 3 TO 7 S 8 9 10 P Figure 66. Data Transfer Process (Master Read Mode, 2-Byte Transfer) Rev. G | Page 57 of 111 08022-039 SCL NON-ACK FROM MASTER-RECEIVER AD9548 Data Sheet Data Transfer Format Write byte format—the write byte protocol is used to write a register address to the RAM starting from the specified RAM address. S Slave address A W RAM address high byte A RAM address low byte A RAM Data 0 A RAM Data 1 A RAM Data 2 A P Send byte format—the send byte protocol is used to set up the register address for subsequent reads. S Slave address A W RAM address high byte A RAM address low byte A P Receive byte format—the receive byte protocol is used to read the data byte(s) from RAM starting from the current address. S Slave address R A RAM Data 0 A RAM Data 1 A RAM Data 2 P A Read byte format—the combined format of the send byte and the receive byte. S Slave Address W A RAM Address High Byte A RAM Address Low Byte A Sr Slave Address R A RAM Data 0 A RAM Data 1 A RAM Data 2 A I²C Serial Port Timing SDA tLO tF tR tSU; DAT tHD; STA tSP tBUF tR tF tHD; STA S tHD; DAT tHI tSU; STO tSU; STA Sr Figure 67. I²C Serial Port Timing Table 35. I2C Timing Definitions Parameter fSCL tBUF tHD; STA tSU; STA tSU; STO tHD; DAT tSU; DAT tLO tHI tR tF tSP Description Serial clock Bus free time between stop and start conditions Repeated hold time start condition Repeated start condition setup time Stop condition setup time Data hold time Date setup time SCL clock low period SCL clock high period Minimum/maximum receive SCL and SDA rise time Minimum/maximum receive SCL and SDA fall time Pulse width of voltage spikes that must be suppressed by the input filter Rev. G | Page 58 of 111 P S 08022-040 SCL P Data Sheet AD9548 Note that the EEPROM storage sequence registers (Address 0x0E10 to Address 0x0E3F) are an exception to the above convention (see the EEPROM Instructions section). BUFFERED/ACTIVE REGISTERS There are two broad categories of registers in the AD9548— buffered and active (see Figure 68). Buffered registers need an input/output update to apply their contents to the internal device functions. In contrast, active registers do not require an input/output update to transfer data between the buffer registers and the internal device functions. In operation, the user programs as many buffer registers as desired and then issues an input/output update. The input/output update occurs by writing to Register 0x0005, Bit 0 = 1 (or by the external application of the necessary logic level to one of the multifunction pins previously programmed as an input/output update input). The contents of buffer registers connected directly to the internal device functions affect those functions immediately. The contents of buffer registers that connect to active registers do not affect the internal device functions until the input/output update event occurs. An L in the Opt column of the register map indicates an active (or live) register. An S or a C in the Opt column of the register map identifies a buffered register. An S entry means that the input/output update signal to the active register is synchronized with the serial port clock or with an input signal driving one of the multifunction pins. On the other hand, a C entry means that the input/output update signal to the active register is synchronized with a clock signal derived from the internal system clock (fS/32), as shown in Figure 68. When reading back a register that has both buffered and active contents, the user can use Register 0x0004, Bit 0 to select whether to read back the buffer or active contents. Readback of the active contents occurs when Register 0x0004, Bit 0 = 0, and readback of the buffer contents occurs when Register 0x0004, Bit 0= 1. Note that a read-only active register requires an input/output update before reading its contents. EDGE DETECT 5 SDIO 3 SDO 4 SCLK/SCL 2 08022-041 CS/SDA TO INTERNAL DEVICE FUNCTIONS SERIAL CONTROL PORT ACTIVE C REGISTERS fS/32 ACTIVE S REGISTERS In general, when a group of registers defines a control parameter, the LSB of the value resides in the D0 position of the register with the lowest address. The bit weight increases right to left, from the lowest register address to the highest register address. For example, the default value of the incremental phase lock offset step size register (Address 0x0314 to Address 0x0315) is the 16-bit hexadecimal number, 0x03E8 (not 0xE803). FROM MULTIFUNCTION PIN LOGIC BUFFER REGISTERS The register map spans an address range from 0x0000 through 0x0E3F (0 to 3647, decimal). Each address provides access to one byte (eight bits) of data. Each individual register is identified by its four-digit hexadecimal address (for example, Register 0x0A10). In some cases, a group of addresses collectively defines a register (for example, the IRQ mask register consists of Register 0x0209, Register 0x020A, Register 0x020B, Register 0x020C, Register 0x020D, Register 0x020E, Register 0x020F, and Register 0x0210). I/O UPDATE INPUT/OUTPUT PROGRAMMING REGISTERS Figure 68. Buffered and Active Registers AUTOCLEAR REGISTERS An A in the Opt column of the register map identifies an autoclear register. Typically, the active value for an autoclear register takes effect following an input/output update. The bit is cleared by the internal device logic upon completion of the prescribed action. REGISTER ACCESS RESTRICTIONS Read and write access to the register map may be restricted based on the register in question, the source and direction of access, and the current state of the device. Each register can be classified as one or more access types. When more than one type applies, the most restrictive condition that applies at the moment is used. Whenever access is denied to a register, all attempts to read the register return a 0 byte, and all attempts to write to the register are ignored. Access to nonexistent registers is handled in the same way as for a denied register. Regular Access Registers with regular access do not fall into any other category. Both read and write access to registers of this type can be from either the serial ports or EEPROM controller. Only one of these sources can have access to a register at any given time (access is mutually exclusive). When the EEPROM controller is active, either in load or store mode, it has exclusive access to these registers. Read-Only Access An R in the Opt column of the register map identifies read-only registers. Access is available at all times, including when the EEPROM controller is active. Exclusion from EEPROM Access An E in the Opt column of the register map identifies a register with contents that are inaccessible to the EEPROM. The contents of this type of register cannot be transferred directly to the EEPROM or vice versa. Note that read-only registers (R) are inaccessible to the EEPROM, as well. Rev. G | Page 59 of 111 AD9548 Data Sheet REGISTER MAP The register addresses and defaults are hexadecimal values. Use the default value when writing to registers and/or bits marked as unused. Register addresses that are not listed in Table 36 are not used, and writing to those registers has no effect. The user should write the default value to sections of registers marked reserved. In the Opt (Option) column, A = autoclear; E = inaccessible to the EEPROM; L = live register (input/output update not required); R = read only; S = buffered register (update synchronous with serial port clock); and C = buffered register (update synchronous with SYSCLK/32). See the Input/Output Programming Registers section for details. Table 36. Addr Opt1 Name D7 D6 Serial Port Control and Part Identification 0x0000 L, E SPI control UniLSB first/ directional Inc Addr 0x0000 Dup I2C control Unused 0x0001 LE Reserved 0x0002 R, L Reserved 0x0003 R, L 0x0004 L,E Readback I/O update L, A, E System Clock (SYSCLK) 0x0100 S D5 D4 Soft reset Long instruction S S 0x0103 C Nom SYSCLK period 0x0104 C 0x0105 C 0x0106 C System clock stability 0x0107 C 0x0108 C General Configuration 0x0200 S M0 0x0201 S M1 0x0202 S M2 0x0203 S M3 0x0204 S M4 0x0205 S M5 0x0206 S M6 0x0207 S M7 0x0208 C IRQ pin output mode 0x0209 C IRQ mask D2 D1 0x00 Read buffer register I/O update Unused Charge pump current [2:0] Charge pump mode (auto/ man) Unused M-divider reset Lock detect timer disable N-divider [7:0] PLL enable 2×frequency multiplier enable Nominal system clock period (femtoseconds) [15:0] [1 ns @ 1 ppm accuracy] M-divider [1:0] Unused SYSCLK reference select [1:0] System clock stability period (milliseconds) [19:16] M0 in/out M1 in/out M2 in/out M3 in/out M4 in/out M5 in/out M6 in/out M7 in/out M0 function [6:0] M1 function [6:0] M2 function [6:0] M3 function [6:0] M4 function [6:0] M5 function [6:0] M6 function [6:0] M7 function [6:0] Unused Unused SYSCLK unlocked Unused 0x020A C 0x020B C 0x020C C 0x020D C Ref AA new profile Ref AA validated Ref AA fault cleared 0x020E C Ref BB new profile Ref BB validated 0x020F C Ref CC new profile Ref CC validated Ref BB fault cleared Ref CC fault cleared Switching Lock detect divider [1:0] Nominal system clock period [20:16] System clock stability period (milliseconds) [15:0] Unused Closed Free-run Unused IRQ pin output mode [1:0] Unused Unused Distribution sync Freq unlocked Frequency unclamped Ref A new profile Watchdog timer Freq locked Frequency clamped Ref A validated Ref BB fault Ref B new profile Ref B validated Ref CC fault Ref C new profile Ref C validated SYSCLK locked Holdover History updated Ref AA fault Rev. G | Page 60 of 111 Def 0x10 Unused Unused Silicon revision number Device ID Unused External loop filter enable D0 Unused Soft reset 0x0005 0x0101 0x0102 D3 SYSCLK Cal complete EEPROM fault Phase unlocked Phase slew unlimited Ref A fault cleared Ref B fault cleared Ref C fault cleared SYSCLK Cal started EEPROM complete Phase locked Phase slew limited Ref A fault 0xC6 0x48 0x00 0x00 0x18 0x28 0x45 0x40 0x42 0x0F 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Ref B fault 0x00 Ref C fault 0x00 Data Sheet AD9548 Addr 0x0210 Opt1 C Name D7 Ref DD new profile D6 Ref DD validated D5 Ref DD fault cleared D4 Ref DD fault D3 Ref D new profile D2 Ref D validated 0x0211 0x0212 0x0213 0x0214 C C S S Watchdog timer DPLL 0x0300 0x0301 0x0302 0x0303 0x0304 0x0305 0x0306 0x0307 0x0308 0x0309 0x030A 0x030B 0x030C 0x030D 0x030E 0x030F 0x0310 0x0311 0x0312 0x0313 0x0314 0x0315 0x0316 0x0317 0x0318 0x0319 0x031A 0x031B C C C C C C A, C C C C C C C C C C C C C C C C C C C C C C Free running frequency tuning word Free running frequency tuning word [47:0] Update TW Pull-in range limits Unused Pull-in range lower limit [23:0] D1 Ref D fault cleared D0 Ref D fault Watchdog timer (ms) [15:0] [up to 65.5 sec] DAC current DAC full-scale current [7:0] Unused DAC shutdown DAC full-scale current [9:8] Update TW Pull-in range upper limit [23:0] Open loop phase offset DDS phase offset word [15:0] Closed loop phase offset Fixed phase lock offset [39:0] (picoseconds; signed) Incremental phase lock offset step size [15:0] (picoseconds) Phase slew rate limit [15:0] (ns/sec) Phase slew limit History accumulation timer [23:0] (milliseconds) History accumulation timer History mode Clock Distribution Output 0x0400 S Distribution settings Unused Unused 0x0401 S 0x0402 S 0x0403 C 0x0404 S 0x0405 S Unused 0x0406 S Unused Distribution enable Distribution synchronization Automatic synchronization Distribution channel modes Unused External distribution resistor Unused Single sample fallback Persistent history Receiver mode OUT3 powerdown OUT3 enable OUT3 sync mask Sync source [1:0] Unused Unused OUT0 CMOS phase invert OUT1 CMOS phase invert OUT2 CMOS phase invert Incremental average [2:0] OUT2 powerdown OUT2 enable OUT2 sync mask OUT1 powerdown OUT1 enable OUT1 sync mask OUT0 powerdown OUT0 enable OUT0 sync mask Def 0x00 0x00 0x00 0xFF 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0xFF 0xFF 0xFF 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0xE8 0x03 0x00 0x00 0x30 0x75 0x00 0x00 0x00 0x00 0x00 Automatic sync mode [1:0] 0x00 OUT0 polarity invert OUT0 drive strength OUT0 mode 0x03 OUT1 polarity invert OUT1 drive strength OUT1 mode 0x03 OUT2 polarity invert OUT2 drive strength OUT2 mode 0x03 Rev. G | Page 61 of 111 AD9548 Addr 0x0407 Opt1 S Data Sheet Name 0x0408 S 0x0409 S 0x040A S 0x040B S 0x040C S 0x040D S 0x040E S 0x040F S 0x0410 S 0x0411 S 0x0412 S 0x0413 S 0x0414 S 0x0415 S 0x0416 S 0x0417 S Reference Inputs 0x0500 S Distribution channel dividers 0x0501 0x0502 0x0503 S S C Reference logic family 0x0504 C 0x0505 C 0x0506 C 0x0507 C L L L L L L L L L L L L L L L L L D6 Unused D5 OUT3 CMOS phase invert D4 OUT3 polarity invert D3 OUT3 drive strength D2 D1 OUT3 mode D0 Q0 [23:0] Unused Q0 [29:24] Unused Q1 [29:24] Q2 [23:0] Unused Q2 [29:24] Q3 [23:0] Unused Reference power-down Manual reference profile selection Reference period Tolerance Q3 [29:24] Ref DD Ref D Ref CC Ref C powerpowerpowerpowerdown down down down Ref BB logic family [1:0] Ref B logic family [1:0] Ref DD logic family [1:0] Ref D logic family [1:0] Ref AA manual profile [2:0] Enable Ref AA manual profile Ref BB manual profile [2:0] Enable Ref BB Manual Profile Ref CC manual profile [2:0] Enable Ref CC Manual Profile Ref DD manual profile [2:0] Enable Ref DD Manual Profile Unused Phase lock scale Unused Ref BB Ref B Ref AA Ref A powerpowerpowerpowerdown down down down Ref AA logic family [1:0] Ref A logic family [1:0] Ref CC Logic Family [1:0] Ref C Logic Family [1:0] Ref A manual profile [2:0] Enable Ref A manual profile Ref B manual profile [2:0] Enable Ref B manual profile Ref C manual profile [2:0] Enable Ref C manual profile Ref D manual profile [2:0] Enable Ref D manual profile Phase master threshold priority [2:0] Promoted priority [2:0] Selection priority [2:0] Nominal period (femtoseconds) [47:0] (up to 1.125 sec) Unused Nominal period [49:48] Inner tolerance (1/tolerance) [15:0] (removes fault status; 10% down to 1 ppm) Unused Inner tolerance [19:16] Outer tolerance (1/tolerance) [15:0] (indicates fault status; 10% down to 1 ppm) Unused Validation Redetect timeout Outer tolerance [19:16] Validation timer (milliseconds) [15:0] (up to 65.5 sec) Redetect timer (milliseconds) [15:0] [up to 65.5 seconds] Rev. G | Page 62 of 111 Def 0x03 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Q1 [23:0] Phase buildout switching Profile Registers—Profile 0 0x0600 L Priorities 0x0601 0x0602 0x0603 0x0604 0x0605 0x0606 0x0607 0x0608 0x0609 0x060A 0x060B 0x60C 0x060D 0x060E 0x060F 0x0610 0x0611 D7 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Data Sheet Addr 0x0612 0x0613 Opt1 L L 0x0614 0x0615 L L 0x0616 0x0617 0x0618 0x0619 0x061A L L L L L 0x061B 0x061C L L Name Digital loop filter coefficients L L L L L L L L L L L L L L L L L D7 D6 D5 D4 D3 Alpha-0 linear [15:0] Alpha-2 exponent [1:0] D2 D1 D0 Alpha-1 exponent [5:0] Beta-0 linear [6:0] Unused Tolerance Beta-0 linear [16:15] Gamma-1 exponent [4:0] Gamma-0 linear [16] Delta-0 linear [7:0] Delta-0 linear [14:8] Delta-1 exponent [0] Reference period Alpha-2 exponent [2] Beta-0 linear [14:7] Beta-1 exponent [4:0] Gamma-0 linear [15:0] Unused 0x061D L 0x061E L Frequency multiplication 0x061F L 0x0620 L 0x0621 L 0x0622 L 0x0623 L 0x0624 L 0x0625 L 0x0626 L 0x0627 L 0x0628 L 0x0629 L Lock detectors 0x062A L 0x062B L 0x062C L 0x062D L 0x062E L 0x062F L 0x0630 L 0x0631 L Profile Registers—Profile 1 0x0632 L Priorities 0x0633 0x0634 0x0635 0x0636 0x0637 0x0638 0x0639 0x063A 0x063B 0x063C 0x06CD 0x063E 0x063F 0x0640 0x0641 0x0642 0x0643 AD9548 Alpha-3 exponent [3:0] Delta-1 exponent [4:1] V [9:8] Selection priority [2:0] 0x00 R [29:24] S [29:24] V [7:0] U [3:0] Unused U [9:4] Phase lock threshold (picoseconds) [15:0] Unused Phase lock fill rate [7:0] Phase lock drain rate [7:0] Frequency lock threshold (picoseconds) [23:0] Frequency lock fill rate [7:0] Frequency lock drain rate [7:0] Phase lock scale Unused Promoted priority [2:0] Nominal period (femtoseconds) [47:0] (up to 1.125 sec) Unused Nominal period [49:48] Inner tolerance (1/tolerance) [15:0] (removes fault status; 10% down to 1 ppm) Unused Inner tolerance [19:16] Outer tolerance (1/tolerance) [15:0] (indicates fault status; 10% down to 1 ppm) Unused Validation Redetect timeout Outer tolerance [19:16] Validation timer (milliseconds) [15:0] (up to 65.5 sec) Redetect timer (milliseconds) [15:0] (up to 65.5 sec) Rev. G | Page 63 of 111 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 S [23:0] Unused 0x00 0x00 0x00 0x00 R [23:0] Unused Def 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 AD9548 Addr 0x0644 0x0645 0x0646 0x0647 Opt1 L L L L 0x0648 0x0649 0x064A 0x064B 0x064C L L L L L 0x064D 0x064E L L Data Sheet Name Digital loop filter coefficients L L L L L L L L L L L L L L L L L D6 D5 D4 D3 Alpha-0 linear [15:0] Alpha-2 exponent [1:0] D2 D1 D0 Alpha-1 exponent [5:0] Beta-0 linear [6:0] Unused Tolerance Beta-0 linear [16:15] Gamma-1 exponent [4:0] Gamma-0 linear [16] Delta-0 linear [7:0] Delta-0 linear [14:8] Delta-1 exponent [0] Reference period Alpha-2 exponent [2] Beta-0 linear [14:7] Beta-1 exponent [4:0] Gamma-0 linear [15:0] Unused 0x064F L 0x0650 L Frequency multiplication 0x0651 L 0x0652 L 0x0653 L 0x0654 L 0x0655 L 0x0656 L 0x0657 L 0x0658 L 0x0659 L 0x065A L 0x065B L Lock detectors 0x065C L 0x065D L 0x065E L 0x065F L 0x0660 L 0x0661 L 0x0662 L 0x0663 L 0x0664 to 0x067F Profile Registers—Profile 2 0x0680 L Priorities 0x0681 0x0682 0x0683 0x0684 0x0685 0x0686 0x0687 0x0688 0x0689 0x068A 0x068B 0x068C 0x068D 0x068E 0x068F 0x0690 0x0691 D7 Alpha-3 exponent [3:0] Delta-1 exponent [4:1] V [9:8] 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Selection priority [2:0] 0x00 R [29:24] S [23:0] Unused S [29:24] V [7:0] U [3:0] Unused U [9:4] Phase lock threshold (picoseconds) [15:0] Unused Phase lock fill rate [7:0] Phase lock drain rate [7:0] Frequency lock threshold (picoseconds) [23:0] Frequency lock fill rate [7:0] Frequency lock drain rate [7:0] Unused Phase lock scale Unused Promoted priority [2:0] Nominal period (femtoseconds) [47:0] (up to 1.125 sec) Unused Nominal period [49:48] Inner tolerance (1/tolerance) [15:0] (removes fault status; 10% down to 1 ppm) Unused Inner tolerance [19:16] Outer tolerance (1/tolerance) [15:0] (indicates fault status; 10% down to 1 ppm) Unused Validation Redetect timeout Outer tolerance [19:16] Validation timer (milliseconds) [15:0] (up to 65.5 sec) Redetect timer (milliseconds) [15:0] (up to 65.5 seconds) Rev. G | Page 64 of 111 0x00 0x00 0x00 0x00 0x00 0x00 0x00 R [23:0] Unused Def 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Data Sheet Addr 0x0692 0x0693 0x0694 0x0695 Opt1 L L L L 0x0696 0x0697 0x0698 0x0699 0x069A L L L L L 0x069B 0x069C L L Name Digital loop filter coefficients L L L L L L L L L L L L L L L L L D7 D6 D5 D4 D3 Alpha-0 linear [15:0] Alpha-2 exponent [1:0] D2 D1 D0 Alpha-1 exponent [5:0] Beta-0 linear [6:0] Unused Tolerance Beta-0 linear [16:15] Gamma-1 exponent [4:0] Gamma-0 linear [16] Delta-0 linear [7:0] Delta-0 linear [14:8] Delta-1 exponent [0] Reference period Alpha-2 exponent [2] Beta-0 linear [14:7] Beta-1 exponent [4:0] Gamma-0 linear [15:0] Unused 0x069D L 0x069E L Frequency multiplication 0x069F L 0x06A0 L 0x06A1 L 0x06A2 L 0x06A3 L 0x06A4 L 0x06A5 L 0x06A6 L 0x06A7 L 0x06A8 L 0x06A9 L Lock detectors 0x06AA L 0x06AB L 0x06AC L 0x6AD L 0x06AE L 0x06AF L 0x06B0 L 0x06B1 L Profile Registers—Profile 3 0x06B2 L Priorities 0x06B3 0x06B4 0x06B5 0x06B6 0x06B7 0x06B8 0x06B9 0x06BA 0x06BB 0x06BC 0x06BD 0x06BE 0x06BF 0x06C0 0x06C1 0x06C2 0x06C3 AD9548 Alpha-3 exponent [3:0] Delta-1 exponent [4:1] V [9:8] 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Selection priority [2:0] 0x00 R [29:24] S [23:0] Unused S [29:24] V [7:0] U [3:0] Unused U [9:4] Phase lock threshold (picoseconds) [15:0] Unused Phase lock fill rate [7:0] Phase lock drain rate [7:0] Frequency lock threshold (picoseconds) [23:0] Frequency lock fill rate [7:0] Frequency lock drain rate [7:0] Phase lock scale Unused Promoted priority [2:0] Nominal period (femtoseconds) [47:0] (up to 1.125 sec) Unused Nominal period [49:48] Inner tolerance (1/tolerance) [15:0] (removes fault status; 10% down to 1 ppm) Unused Inner tolerance [19:16] Outer tolerance (1/tolerance) [15:0] (indicates fault status; 10% down to 1 ppm) Unused Validation Redetect timeout Outer tolerance [19:16] Validation timer (milliseconds) [15:0] (up to 65.5 sec) Redetect timer (milliseconds) [15:0] (up to 65.5 sec) Rev. G | Page 65 of 111 0x00 0x00 0x00 0x00 0x00 0x00 0x00 R [23:0] Unused Def 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 AD9548 Addr 0x06C4 0x06C5 0x06C6 0x06C7 Opt1 L L L L 0x06C8 0x06C9 L L 0x06CA 0x06CB 0x06CC L L L 0x06CD 0x06CE L L Data Sheet Name Digital loop filter coefficients D7 D6 D5 D4 D3 Alpha-0 linear [15:0] Alpha-2 exponent [1:0] D2 D1 Alpha-1 exponent [5:0] Beta-0 linear [6:0] Beta-0 linear [14:7] Beta-1 exponent [4:0] Unused D0 Alpha-2 exponent [2] 0x00 Beta-0 linear [16:15] 00 Gamma-0 linear [15:0] Unused Delta-1 exponent [0] Gamma-1 exponent [4:0] Gamma-0 linear [16] Delta-0 linear [7:0] Delta-0 linear [14:8] 0x06CF L Alpha-3 exponent [3:0] Delta-1 exponent [4:1] 0x06D0 L R [23:0] Frequency multiplication 0x06D1 L 0x06D2 L 0x06D3 L Unused R [29:24] 0x06D4 L S [23:0] 0x06D5 L 0x06D6 L 0x06D7 L Unused S [29:24] 0x06D8 L V [7:0] 0x06D9 L U [3:0] Unused V [9:8] 0x06DA L Unused U [9:4] 0x06DB L Phase lock threshold (picoseconds) [15:0] Lock detectors 0x06DC L 0x06DD L Phase lock fill rate [7:0] 0x06DE L Phase lock drain rate [7:0] 0x06DF L Frequency lock threshold (picoseconds) [23:0] 0x06E0 L 0x06E1 L 0x06E2 L Frequency lock fill rate [7:0] 0x06E3 L Frequency lock drain rate [7:0] L Unused 0x06E40x06FF Profile Registers—Profile 4 Through Profile 7 L 0x0700Profile 4 The functionality of the Profile 4 through Profile 7 address locations (Address 0x to Address 0x07FF) is identical to that 0x07FF through of the Profile 0 through Profile 3 address locations (Address 0x0600 to Address 0x06FF). Profile 7 Operational Controls 0x0A00 S Unused General Reset Sans SYSCLK Reference TDC DAC Dist Full power-down reg map powerpowerpowerpowerpowerpowerdown down down down down down 0x0A01 C Loop mode Unused User selection mode [1:0] User reference selection [2:0] User User holdover free-run 0x0A02 L Cal/sync Unused Sync Calibrate distribution system clock 0x0A03 A, C Reset Func Unused Clear LF Clear CCI Clear phase Reset auto Reset Reset Reset accumulator sync TW history all IRQs watchdog 0x0A04 A, C IRQ clearing Unused Unused Unused SYSCLK SYSCLK SYSCLK Cal SYSCLK Cal unlocked locked complete started 0x0A05 A, C Unused Distribution Watchdog EEPROM EEPROM sync timer fault complete 0x0A06 A, C Switching Closed Free-run Holdover Freq Freq Phase Phase unlocked locked unlocked locked 0x0A07 A, C Unused History Freq Freq Phase slew Phase slew updated unclamped clamped unlimited limited Rev. G | Page 66 of 111 Def 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Data Sheet Addr 0x0A08 Opt1 A, C 0x0A09 Name AD9548 D7 Ref AA new profile D6 Ref AA validated A, C Ref BB new profile Ref BB validated 0x0A0A A, C Ref CC new profile Ref CC validated 0x0A0B A, C Ref DD new profile Ref DD validated 0x0A0C A, C 0x0A0D A, C Incremental phase offset Reference profile detect 0x0A0E A, C Force validation timeout 0x0A0F C Reference monitor override 0x0A10 C Reference monitor bypass User Scratch Pad (Eight Bytes) 0x0C00 L Clock part serial ID 0x0C01 L D5 Ref AA fault cleared Ref BB fault cleared Ref CC fault cleared Ref DD fault cleared Unused D4 Ref AA fault D3 Ref A new profile D2 Ref A validated Ref BB fault Ref B new profile Ref B validated Ref CC fault Ref C new profile Ref C validated Ref DD fault Ref D new profile Ref D validated D0 Ref A fault Def 0x00 Ref B fault 0x00 Ref C fault 0x00 Ref D fault 0x00 Increment phase offset Detect A 0x00 Detect DD Detect D Detect CC Detect C Detect BB Reset phase offset Detect B Force Timeout DD Force Timeout D Force Timeout CC Force Timeout C Force Timeout BB Force Timeout B Force Timeout AA Force Timeout A 0x00 Ref Mon Override DD Ref Mon Override D Ref Mon Bypass D Ref Mon Override CC Ref Mon Bypass CC Ref Mon Override C Ref Mon Override BB Ref Mon Bypass BB Ref Mon Override B Ref Mon Override AA Ref Mon Bypass AA Ref Mon Override A 0x00 Ref Mon Bypass A 0x00 Ref Mon Bypass DD Ref Mon Bypass C Ref Mon Bypass B Write user scratch pad[63:0] 0x0C02 S 0x0C03 S 0x0C04 C 0x0C05 C 0x0C06 C 0x0C07 C Status (These registers are read only and are accessible during EEPROM transactions.) 0x0D00 R, L EEPROM Unused 0x0D01 R, L System clock 0x0D02 R, L IRQ monitor 0x0D03 R, L 0x0D04 R, L 0x0D05 R, L 0x0D06 R, L Ref AA new profile Ref AA validated 0x0D07 R, L Ref BB new profile Ref BB validated 0x0D08 R, L Ref CC new profile Ref CC validated 0x0D09 R, L Ref DD new profile Ref DD validated 0x0D0A R, C 0x0D0B R, C Offset slew limiting Frequency clamped Phase build-out History available Unused Stable Unused SYSCLK locked Unused Unused History updated Ref AA fault Distribution sync Freq unlocked Freq unclamped Ref A new profile Watchdog timer Freq locked Freq clamped Ref A validated Ref BB fault Ref B new profile Ref B validated Ref CC fault Ref C new profile Ref C validated Ref DD fault Ref D new profile Ref D validated Loop switching Active reference priority [3:0] Holdover SYSCLK unlocked Unused Closed Free-run Unused Ref AA fault cleared Ref BB fault cleared Ref CC fault cleared Ref DD fault cleared Freq lock Holdover Phase lock Rev. G | Page 67 of 111 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Fault detected Unused Unused Switching DPLL status D1 Ref A fault cleared Ref B fault cleared Ref C fault cleared Ref D fault cleared Decrement phase offset Detect AA Load in progress Cal in progress SYSCLK Cal complete EEPROM fault Phase unlocked Phase slew unlimited Ref A fault cleared Ref B fault cleared Ref C fault cleared Ref D fault cleared Active Save in progress Lock detected SYSCLK Cal started EEPROM complete Phase locked Phase slew limited Ref A fault Ref B fault Ref C fault Ref D fault Free running Active reference [3:0] AD9548 Data Sheet Addr 0x0D0C Opt1 R, C Name Ref A 0x0D0D R, C Ref AA 0x0D0E R, C Ref B 0x0D0F R, C Ref BB 0x0D10 R, C Ref C 0x0D11 R, C Ref CC 0x0D12 R. C Ref D 0x0D13 R, C Ref DD D7 Profile selected Profile selected Profile selected Profile selected Profile selected Profile selected Profile selected Profile selected D6 0x0D14 R, C Holdover history 0x0D15 R, C 0x0D16 R, C 0x0D17 R, C 0x0D18 R, C 0x0D19 R, C Nonvolatile Memory (EEPROM) Control 0x0E00 L Write protect 0x0E01 0x0E02 L, E L, A, E L, A, E Condition Save 0x0E10 0x0E11 0x0E12 0x0E13 0x0E14 L, E L, E L, E L, E L, E System clock 0x0E15 0x0E16 0x0E17 0x0E18 0x0E19 0x0E1A 0x0E1B 0x0E1C 0x0E1D 0x0E1E 0x0E1F 0x0E20 0x0E21 0x0E22 0x0E23 0x0E24 0x0E25 0x0E26 0x0E27 0x0E28 0x0E29 0x0E2A 0x0E2B 0x0E2C 0x0E2D L, E L, E L, E L, E L, E L, E L, E L, E L, E L, E L, E L, E L, E L,E L, E L, E L, E L, E L, E L, E L, E L, E L, E L, E L, E 0x0E03 Load I/O update SYSCLK calibrate General D5 D4 Selected profile [2:0] D3 Valid D2 Fault D1 Fast D0 Slow Selected profile [2:0] Valid Fault Fast Slow Selected profile [2:0] Valid Fault Fast Slow Selected profile [2:0] Valid Fault Fast Slow Selected profile [2:0] Valid Fault Fast Slow Selected profile [2:0] Valid Fault Fast Slow Selected profile [2:0] Valid Fault Fast Slow Selected profile [2:0] Valid Fault Fast Slow Def Tuning word readback [47:0] Unused Half rate mode Condition value [4:0] Unused Unused Unused Load from EEPROM EEPROM storage sequence Data: 9 bytes Address: 0x0100 Action: IO_Update Action: calibrate system clock Data: 21 bytes Address: 0x0200 DPLL Data: 28 bytes Address: 0x0300 Clock distribution Data: 26 bytes Address: 0x0400 I/O update Reference inputs Action: IO_Update Data: 8 bytes Address: 0x0500 Profile 0 and Profile 1 Data: 100 bytes Address: 0x0600 Profile 2 and Profile 3 Data: 100 bytes Address: 0x0680 Profile 4 and Profile 5 Data: 100 bytes Address: 0x0700 Profile 6 and Profile 7 Data: 100 bytes Address: 0x0780 Rev. G | Page 68 of 111 Write enable Save to EEPROM Unused 0x00 0x00 0x00 0x00 0x08 0x01 0x00 0x80 0xA0 0x14 0x02 0x00 0xB 0x03 0x00 0x19 0x04 0x00 0x80 0x07 0x05 0x00 0x63 0x06 0x00 0x63 0x06 0x80 0x63 0x07 0x00 0x63 0x07 0x80 Data Sheet Addr 0x0E2E 0x0E2F 0x0E30 0x0E31 0x0E32 0x0E33 0x0E34 to 0x0E3F 1 Opt1 L, E L, E L, E L, E L, E L, E L, E Name I/O update Operational controls I/O update End of data AD9548 D7 D6 D5 D4 D3 Action: I/O update Data: 17 bytes Address: 0x0A00 Action: I/O update Action: end of data Continuation of scratch pad area For details regarding the options in the Opt column, see the Input/Output Programming Registers section. Rev. G | Page 69 of 111 D2 D1 D0 Def 0x80 0x10 0x0A 0x00 0x80 0xFF AD9548 Data Sheet REGISTER MAP BIT DESCRIPTIONS SERIAL PORT CONFIGURATION (REGISTER 0x0000 TO REGISTER 0x0005) Table 37. Serial Configuration Address 0x0000 Bits [7] Bit Name Unidirectional [6] LSB first [5] Soft reset [4] [0] Long instruction Unused Description Select SPI port SDO pin operating mode. 0 (default) = 3-wire. 1 = 4-wire (SDO pin enabled). Bit order for SPI port. 0 (default) = most significant bit and byte first. 1 = least significant bit and byte first. Device reset (invokes an EEPROM download if M[7:3] ≠ 0). 0 (default) = normal operation. 1 = reset. 16-bit mode (the only mode supported by the device). This bit is read only and reads back as Logic 1. Table 38. Reserved Register Address 0x0001 Bits [7:0] Bit Name Unused Description Table 39. Silicon Revision Level (Read Only) Address 0x0002 Bits [7:0] Bit Name Reserved Description Default = 0xC6 = 0b11000110 Bit Name Reserved Description Default = 0x48 = 0b01001000 Table 40. Device ID (Read Only) Address 0x0003 Bits [7:0] Table 41. Register Readback Control Address 0x0004 Bits [7:1] 0 Bit Name Unused Read buffer register Description For buffered registers, serial port readback reads from actual (active) registers instead of from the buffer. 0 (default) = reads values currently applied to the internal logic of the device. 1 = reads buffered values that take effect on the next assertion of the I/O update. Table 42. Soft Input/Output Update Address 0x0005 Bits [7:1] 0 Bit Name Unused I/O update Description Writing a 1 to this bit transfers the data in the serial I/O buffer registers to the internal control registers of the device. This is an autoclearing bit. Rev. G | Page 70 of 111 Data Sheet AD9548 SYSTEM CLOCK (REGISTER 0x0100 TO REGISTER 0x0108) Table 43. Charge Pump and Lock Detect Control Address 0x0100 Bits [7] Bit Name External loop filter enable [6] Charge pump mode [5:3] Charge pump current [2] Lock detect timer disable [1:0] Lock detect timer Description Enables use of an external SYSCLK PLL loop filter 0 (default) = internal loop filter 1 = external loop filter Charge pump current control 0 (default) = automatic 1 = manual Selects charge pump current when Bit 6 = 1 000 = 125 μA 001 = 250 μA 010 = 375 μA 011 (default) = 500 μA 100 = 625 μA 101 = 750 μA 110 = 875 μA 111 = 1000 μA Enable the SYSCLK PLL lock detect timer 0 (default) = enable 1 = disable Select lock detect timer depth 00 (default) = 128 01 = 256 10 = 512 11 = 1024 Table 44. N Divider Address 0x0101 Bits [7:0] Bit Name N-divider Description System clock PLL feedback divider value: 6 ≤ N ≤ 255 (default = 0x28 = 40) Table 45. SYSCLK Input Options Address 0x0102 Bits [7] [6] Bit Name Unused M-divider reset [5:4] M-divider [3] 2× frequency multiplier enable [2] PLL enable [1:0] System clock source Description Reset the M-divider 0 = normal operation 1 (default) = reset When not using the M-divider, program this bit to Logic 1. System clock input divider 00 (default) = 1 01 = 2 10 = 4 11 = 8 Enable the 2× frequency multiplier 0 (default) = disable 1 = enable Enable the SYSCLK PLL 0 = disable 1 (default) = enable Input mode select for SYSCLKx pins 00 = crystal resonator 01 (default) = low frequency clock source 10 = high frequency (direct) clock source 11 = input receiver power-down Rev. G | Page 71 of 111 AD9548 Data Sheet Table 46. Nominal System Clock (SYSCLK) Period1 Address 0x0103 Bits [7:0] 0x0104 [7:0] 0x0105 [7:5] [4:0] 1 Bit Name System clock period (expressed in femtoseconds) Description System clock period, Bits[7:0] System clock period, Bits[15:8] Unused System clock period System clock period, Bits[20:16] Units are femtoseconds. The default value is 0x0F424 = 1,000,000 (1 ns) and implies a system clock frequency of 1 GHz. Table 47. System Clock Stability Period1 Address 0x0106 0x0107 0x0108 1 Bits [7:0] [7:0] [7:4] [3:0] Bit Name System clock stability period Description System clock stability period, Bits[7:0] (default = 0x01) System clock stability period, Bits[15:8] (default = 0x00) Unused System clock stability period System clock stability period, Bits[19:16] (default = 0x0) (default period = 0x00001, or 1 ms) Units are milliseconds. The default value is 0x000001 = 1 (1 ms). GENERAL CONFIGURATION (REGISTER 0x0200 TO REGISTER 0x0214) Register 0x0200 to Register 0x0207—Multifunction Pin Control (M0 to M7) Table 48. Multifunction Pin (M0 to M7) Control1 Address 0x0200 0x0201 0x0202 0x0203 0x0204 0x0205 0x0206 0x0207 1 Bits [7] Bit Name M0 in/out [6:0] [7] [6:0] [7] [6:0] [7] [6:0] [7] [6:0] [7] [6:0] [7] [6:0] [7] [6:0] M0 function M1 in/out M1 function M2 in/out M2 function M3 in/out M3 function M4 in/out M4 function M5 in/out M5 function M6 in/out M6 function M7 in/out M7 function Description In/out control for the M0 pin 0 (default) = input (control pin) 1 = output (status pin) See Table 25 and Table 26 (default = 0xb0000000) In/out control for the M1 pin (same as M0) See Table 25 and Table 26 (default = 0xb0000000) In/out control for the M2 pin (same as M0) See Table 25 and Table 26 (default = 0xb0000000) In/out control for the M3 pin (same as M0) See Table 25 and Table 26 (default = 0xb0000000) In/out control for the M4 pin (same as M0) See Table 25 and Table 26 (default = 0xb0000000) In/out control for the M5 pin (same as M0) See Table 25 and Table 26 (default = 0xb0000000) In/out control for the M6 pin (same as M0) See Table 25 and Table 26 (default = 0xb0000000) In/out control for the M7 pin (same as M0) See Table 25 and Table 26 (default = 0xb0000000) The default setting for all the multifunction pins is as an unused control input pin. Table 49. IRQ Pin Output Mode Address 0x0208 Bits [7:2] [1:0] Bit Name Unused IRQ pin output mode Description Select the output mode of the IRQ pin 00 (default) = NMOS, open drain (requires an external pull-up resistor) 01 = PMOS, open drain (requires an external pull-down resistor) 10 = CMOS, active high 11 = CMOS, active low Rev. G | Page 72 of 111 Data Sheet AD9548 Register 0x0209 to Register 0x0210—IRQ Mask The IRQ mask register bits form a one-to-one correspondence with the bits of the IRQ monitor register (Address 0x0D02 to Address 0x0D09). When set to Logic 1, the IRQ mask bits enable the corresponding IRQ monitor bits to indicate an IRQ event. The default for all IRQ mask bits is Logic 0, which prevents the IRQ monitor from detecting any internal interrupts. Table 50. IRQ Mask for SYSCLK Address 0x0209 Bits [7:6] [5] [4] [3:2] [1] [0] Bit Name Unused SYSCLK unlocked SYSCLK locked Unused SYSCLK Cal complete SYSCLK Cal started Description Enables IRQ for indicating a SYSCLK PLL state transition from locked to unlocked Enables IRQ for indicating a SYSCLK PLL state transition from unlocked to locked Enables IRQ for indicating that SYSCLK calibration has completed Enables IRQ for indicating that SYSCLK calibration has begun Table 51. IRQ Mask for Distribution Sync, Watchdog Timer, and EEPROM Address 0x020A Bits [7:4] [3] [2] [1] [0] Bit Name Unused Distribution sync Watchdog timer EEPROM fault EEPROM complete Description Enables IRQ for indicating a distribution sync event Enables IRQ for indicating expiration of the watchdog timer Enables IRQ for indicating a fault during an EEPROM load or save operation Enables IRQ for indicating successful completion of an EEPROM load or save operation Table 52. IRQ Mask for the Digital PLL Address 0x020B Bits [7] [6] [5] [4] [3] [2] [1] [0] Bit Name Switching Closed Freerun Holdover Freq unlocked Freq locked Phase unlocked Phase locked Description Enables IRQ for indicating that the DPLL is switching to a new reference Enables IRQ for indicating that the DPLL has entered closed-loop operation Enables IRQ for indicating that the DPLL has entered free-run mode Enables IRQ for indicating that the DPLL has entered holdover mode Enables IRQ for indicating that the DPLL lost frequency lock Enables IRQ for indicating that the DPLL has acquired frequency lock Enables IRQ for indicating that the DPLL lost phase lock Enables IRQ for indicating that the DPLL has acquired phase lock Table 53. IRQ Mask for History Update, Frequency Limit, and Phase Slew Limit Address 0x020C Bits [7:5] [4] [3] [2] [1] Bit Name Unused History updated Frequency unclamped Frequency clamped Phase slew unlimited [0] Phase slew limited Description Enables IRQ for indicating the occurrence of a tuning word history update Enables IRQ for indicating a state transition frequency limiter from clamped to unclamped Enables IRQ for indicating a state transition of the frequency limiter from unclamped to clamped Enables IRQ for indicating a state transition of the phase slew limiter from slew limiting to not slew limiting Enables IRQ for indicating a state transition of the phase slew limiter from not slew limiting to slew limiting Rev. G | Page 73 of 111 AD9548 Data Sheet Table 54. IRQ Mask for Reference Inputs Address 0x020D 0x020E 0x020F 0x0210 Bits [7] [6] [5] [4] [3] [2] [1] [0] [7] [6] [5] [4] [3] [2] [1] [0] [7] [6] [5] [4] [3] [2] [1] [0] [7] [6] [5] [4] [3] [2] [1] [0] Bit Name Ref AA new profile Ref AA validated Ref AA fault cleared Ref AA fault Ref A new profile Ref A validated Ref A fault cleared Ref A fault Ref BB new profile Ref BB validated Ref BB fault cleared Ref BB fault Ref B new profile Ref B validated Ref B fault cleared Ref B fault Ref CC new profile Ref CC validated Ref CC fault cleared Ref CC fault Ref C new profile Ref C validated Ref C fault cleared Ref C fault Ref DD new profile Ref DD validated Ref DD fault cleared Ref DD fault Ref D new profile Ref D validated Ref D fault cleared Ref D fault Description Enables IRQ for indicating that Ref AA has switched to a new profile Enables IRQ for indicating that Ref AA has been validated Enables IRQ for indicating that Ref AA has been cleared of a previous fault Enables IRQ for indicating that Ref AA has been faulted Enables IRQ for indicating that Ref A has switched to a new profile Enables IRQ for indicating that Ref A has been validated Enables IRQ for indicating that Ref A has been cleared of a previous fault Enables IRQ for indicating that Ref A has been faulted Enables IRQ for indicating that Ref BB has switched to a new profile Enables IRQ for indicating that Ref BB has been validated Enables IRQ for indicating that Ref BB has been cleared of a previous fault Enables IRQ for indicating that Ref BB has been faulted Enables IRQ for indicating that Ref B has switched to a new profile Enables IRQ for indicating that Ref B has been validated Enables IRQ for indicating that Ref B has been cleared of a previous fault Enables IRQ for indicating that Ref B has been faulted Enables IRQ for indicating that Ref CC has switched to a new profile Enables IRQ for indicating that Ref CC has been validated Enables IRQ for indicating that Ref CC has been cleared of a previous fault Enables IRQ for indicating that Ref CC has been faulted Enables IRQ for indicating that Ref C has switched to a new profile Enables IRQ for indicating that Ref C has been validated Enables IRQ for indicating that Ref C has been cleared of a previous fault Enables IRQ for indicating that Ref C has been faulted Enables IRQ for indicating that Ref DD has switched to a new profile Enables IRQ for indicating that Ref DD has been validated Enables IRQ for indicating that Ref DD has been cleared of a previous fault Enables IRQ for indicating that Ref DD has been faulted Enables IRQ for indicating that Ref D has switched to a new profile Enables IRQ for indicating that Ref D has been validated Enables IRQ for indicating that Ref D has been cleared of a previous fault Enables IRQ for indicating that Ref D has been faulted Table 55. Watchdog Timer1 Address 0x0211 0x0212 1 Bits [7:0] [7:0] Bit Name Watchdog timer Description Watchdog timer, Bits[7:0] (default = 0x00) Watchdog timer, Bits[15:8] (default = 0x00) The watchdog timer is expressed in milliseconds. The default value is 0 (disabled). Table 56. Auxiliary DAC1 Address 0x0213 0x0214 1 Bits [7:0] [7] Bit Name Full-scale current DAC shutdown [6:2] [1:0] Unused Full-scale current Description Full scale current, Bits[7:0] (default = 0xFF) Shut down the DAC current sources. 0 (default) = normal operation 1 = shut down Full-scale current, Bits[9:8] (default = 0b01) (default current = 0x1FF, or 20.1 mA) The default DAC full-scale current value is 0x01FF = 511, which equates to 20.1375 mA. Rev. G | Page 74 of 111 Data Sheet AD9548 DPLL CONFIGURATION (REGISTER 0x0300 TO REGISTER 0x031B) Table 57. Free Running Frequency Tuning Word1 Address 0x0300 0x0301 0x0302 0x0303 0x0304 0x0305 1 Bits [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] Bit Name Frequency (expressed as a 48-bit frequency tuning word) Description Free running frequency tuning word, Bits[7:0] Free running frequency tuning word, Bits[15:8] Free running frequency tuning word, Bits[23:9] Free running frequency tuning word, Bits[31:24] Free running frequency tuning word, Bits[39:32] Free running frequency tuning word, Bits[47:40] The default free running tuning word is 0x000000 = 0, which equates to 0 Hz. Table 58. Update TW Address 0x0306 Bits [7:1] [0] Bit Name Unused Update TW Description A Logic 1 written to this bit transfers the free running frequency tuning word (Register 0300 to Register 0305) to the register imbedded in the tuning word processing logic. Note that it is not necessary to write the update TW bit when the device is in free-run mode. This is an autoclearing bit. Table 59. Pull-In Range Lower Limit1 Address 0x0307 Bits [7:0] 0x0308 [7:0] Lower limit pull-in range, Bits[15:8] 0x0309 [7:0] Lower limit pull-in range, Bits[23:9] 0x030A [7:0] 0x030B [7:0] Upper limit pull-in range, Bits[15:8] 0x030C [7:0] Upper limit pull-in range, Bits[23:9] 1 Bit Name Pull-in range lower limit (expressed as a 24-bit frequency tuning word) Pull-in range upper limit (expressed as a 24-bit frequency tuning word) Description Lower limit pull-in range, Bits[7:0] Upper limit pull-in range, Bits[7:0] The default pull-in range lower limit is 0, and the upper range limit is 0xFFFFFF, which effectively spans the full output frequency range of the DDS. Table 60. DDS Phase Offset1 Address 0x030D Bits [7:0] 0x030E [7:0] 1 Bit Name Open-loop phase offset (expressed in π/215 radians) Description DDS phase offset, Bits[7:0] DDS phase offset, Bits[15:8] The default DDS phase offset is 0. Table 61. Fixed Closed-Loop Phase Lock Offset1 Address 0x030F 0x0310 0x0311 0x0312 0x0313 1 Bits [7:0] [7:0] [7:0] [7:0] [7:0] Bit Name Fixed phase lock offset (expressed in picoseconds) The default fixed closed loop phase lock offset is 0. Rev. G | Page 75 of 111 Description Fixed phase lock offset, Bits[7:0] Fixed phase lock offset, Bits[15:8] Fixed phase lock offset, Bits[23:16] Fixed phase lock offset, Bits[31:24] Fixed phase lock offset, Bits[39:32] AD9548 Data Sheet Table 62. Incremental Closed-Loop Phase Lock Offset Step Size1 Address 0x0314 Bits [7:0] 0x0315 [7:0] 1 Bit Name Incremental phase lock offset step size (expressed in picoseconds per step) Description Incremental phase lock offset step size, Bits[7:0] Incremental phase lock offset step size, Bits[15:8] The default incremental closed-loop phase lock offset step size value is 0x03E8 = 1000 (1 ns). Table 63. Phase Slew Rate Limit1 Address 0x0316 Bits [7:0] 0x0317 [7:0] 1 Bit Name Phase slew limit (expressed in nanoseconds per second) Description Phase slew rate limit, Bits[7:0] Phase slew rate limit, Bits[15:8] The default phase slew rate limit is 0 (or disabled). Table 64. History Accumulation Timer1 Address 0x0318 Bits [7:0] 0x0319 [7:0] History accumulation timer, Bits[15:8] 0x031A [7:0] History accumulation timer, Bits[23:16] 1 Bit Name History accumulation timer (expressed in milliseconds) Description History accumulation timer, Bits[7:0] Do not program a timer value of 0. The history accumulation timer default value is 0x007530 = 30,000 (30 sec). Table 65. History Mode Address 0x031B Bits [7:5] [4] Bit Name Unused Single-sample fallback [3] Persistent history [2:0] Incremental average Description Controls the holdover history. If tuning word history is not available for the reference that was active just prior to holdover, then 0 (default) = use the free running frequency tuning word register value. 1 = use the last tuning word from the DPLL. Controls the holdover history initialization. When switching to a new reference 0 (default) = clear the tuning word history. 1 = retain the previous tuning word history. History mode value from 0 to 7 (default = 0). See the Frequency Tuning Word History section for details on this register. Rev. G | Page 76 of 111 Data Sheet AD9548 CLOCK DISTRIBUTION OUTPUT CONFIGURATION (REGISTER 0x0400 TO REGISTER 0x0419) Table 66. Distribution Settings1 Address 0x0400 1 Bits [7:6] [5] Bit Name Unused External distribution resistor [4] Receiver mode [3] OUT3 power-down [2] OUT2 power-down [1] OUT1 power-down [0] OUT0 power-down Description Output current control for the clock distribution outputs 0 (default) = internal current setting resistor 1 = external current setting resistor Clock distribution receiver mode 0 (default) = normal operation 1 = high frequency mode (super-Nyquist) Power-down clock distribution output OUT3 0 (default) = normal operation 1 = power-down Power-down clock distribution output OUT2 0 (default) = normal operation 1 = power-down Power-down clock distribution output OUT1 0 (default) = normal operation 1 = power-down Power-down clock distribution output OUT0 0 (default) = normal operation 1 = power-down When Bits[3:0] = 1111, the clock distribution output enters a deep sleep mode. Table 67. Distribution Enable Address 0x0401 Bits [7:4] [3] Bit Name Unused OUT3 enable [2] OUT2 enable [1] OUT1 enable [0] OUT0 enable Description Enable the OUT3 driver. 0 (default) = disable. 1 = enable. Enable the OUT2 driver. 0 (default) = disable. 1 = enable. Enable the OUT1 driver. 0 (default) = disable. 1 = enable. Enable the OUT0 driver. 0 (default) = disable. 1 = enable. Rev. G | Page 77 of 111 AD9548 Data Sheet Table 68. Distribution Synchronization Address 0x0402 Bits [7:6] [5:4] Bit Name Unused Sync source Description [3] OUT3 sync mask [2] OUT2 sync mask [1] OUT1 sync mask [0] OUT0 sync mask Select the sync source for the clock distribution output channels. 00 (default) = direct. 01 = active reference. 10 = DPLL feedback edge. 11 = reserved. Mask the synchronous reset to the OUT3 divider. 0 (default) = unmasked. 1 = masked. Mask the synchronous reset to the OUT2 divider. 0 (default) = unmasked. 1 = masked. Mask the synchronous reset to the OUT1 divider. 0 (default) = unmasked. 1 = masked. Mask the synchronous reset to the OUT0 divider. 0 (default) = unmasked. 1 = masked. Table 69. Automatic Synchronization Address 0x0403 Bits [7:2] [1:0] Bit Name Unused Automatic sync mode Description Autosync mode 00 (default) = disabled 01 = sync on DPLL frequency lock 10 = sync on DPLL phase lock 11 = reserved Table 70. Distribution Channel Modes Address 0x0404 Bits [7:6] [5] Bit Name Unused OUT0 CMOS phase invert [4] OUT0 polarity invert [3] OUT0 drive strength [2:0] OUT0 mode Description When the output mode is CMOS, the bit inverts the relative phase between the two CMOS output pins. Otherwise, this bit is nonfunctional. 0 (default) = not inverted. 1 = inverted. Invert the polarity of OUT0. 0 (default) = not inverted. 1 = inverted. OUT0 output drive capability control. 0 (default) = CMOS: low drive strength; LVDS: 3.5 mA nominal. 1 = CMOS: normal drive strength; LVDS: 7 mA nominal. OUT0 operating mode select. 000 = CMOS (both pins). 001 = CMOS (positive pin), tristate (negative pin). 010 = tristate (positive pin), CMOS (negative pin). 011 (default) = tristate (both pins). 100 = LVDS. 101 = LVPECL. 110 = reserved. 111 = reserved. Rev. G | Page 78 of 111 Data Sheet Address 0x0405 0x0406 AD9548 Bits [7:6] [5] Bit Name Unused OUT1 CMOS phase invert [4] OUT1 polarity invert [3] OUT1 drive strength [2:0] OUT1 mode [7:6] [5] Unused OUT2 CMOS phase invert [4] OUT2 polarity invert [3] OUT2 drive strength [2:0] OUT2 mode Description When the output mode is CMOS, the bit inverts the relative phase between the two CMOS output pins. Otherwise, this bit is nonfunctional. 0 (default) = not inverted. 1 = inverted. Invert the polarity of OUT1. 0 (default) = not inverted. 1 = inverted. OUT1 output drive capability control. 0 (default) = CMOS: low drive strength; LVDS: 3.5 mA nominal. 1 = CMOS: normal drive strength; LVDS: 7 mA nominal. OUT1 operating mode select. 000 = CMOS (both pins). 001 = CMOS (positive pin), tristate (negative pin). 010 = tristate (positive pin), CMOS (negative pin). 011 (default) = tristate (both pins). 100 = LVDS. 101 = LVPECL. 110 = reserved. 111 = reserved. When the output mode is CMOS, the bit inverts the relative phase between the two CMOS output pins. Otherwise, this bit is nonfunctional. 0 (default) = not inverted. 1 = inverted. Invert the polarity of OUT2. 0 (default) = not inverted. 1 = inverted. OUT2 output drive capability control. 0 (default) = CMOS: low drive strength; LVDS: 3.5 mA nominal. 1 = CMOS: normal drive strength; LVDS: 7 mA nominal. OUT2 operating mode select. 000 = CMOS (both pins). 001 = CMOS (positive pin), tristate (negative pin). 010 = tristate (positive pin), CMOS (negative pin). 011 (default) = tristate (both pins). 100 = LVDS. 101 = LVPECL. 110 = reserved. 111 = reserved. Rev. G | Page 79 of 111 AD9548 Address 0x0407 Data Sheet Bits [7:6] [5] Bit Name Unused OUT3 CMOS phase invert [4] OUT3 polarity invert [3] OUT3 drive strength [2:0] OUT3 mode Description When the output mode is CMOS, the bit inverts the relative phase between the two CMOS output pins. Otherwise, this bit is nonfunctional. 0 (default) = not inverted. 1 = inverted. Invert the polarity of OUT3. 0 (default) = not inverted. 1 = inverted. OUT3 output drive capability control. 0 (default) = CMOS: low drive strength; LVDS: 3.5 mA nominal. 1 = CMOS: normal drive strength; LVDS: 7 mA nominal. OUT3 operating mode select. 000 = CMOS (both pins). 001 = CMOS (positive pin), tristate (negative pin). 010 = tristate (positive pin), CMOS (negative pin). 011 (default) = tristate (both pins). 100 = LVDS. 101 = LVPECL. 110 = reserved. 111 = reserved. Register 0x0408 to Register 0x0417—Distribution Channel Dividers Table 71. Q0 Divider1 Address 0x0408 0x0409 0x040A 0x040B 1 Bits [7:0] [7:0] [7:0] [7:6] [5:0] Bit Name Q0 Description Q0 divider, Bits[7:0] Q0 divider, Bits[15:8] Q0 divider, Bits[23:16] Unused Q0 Q0 divider, Bits[29:24] The default value is 0 (or divide by 1). Table 72. Q1 Divider1 Address 0x040C 0x040D 0x040E 0x040F 1 Bits [7:0] [7:0] [7:0] [7:6] [5:0] Bit Name Q1 Description Q1 divider, Bits[7:0] Q1 divider, Bits[15:8] Q1 divider, Bits[23:16] Unused Q1 Q1 divider, Bits[29:24] The default value is 0 (or divide by 1). Table 73. Q2 Divider1 Address 0x0410 0x0411 0x0412 0x0413 1 Bits [7:0] [7:0] [7:0] [7:6] [5:0] Bit Name Q2 Description Q2 divider, Bits[7:0] Q2 divider, Bits[15:8] Q2 divider, Bits[23:16] Unused Q2 Q2 divider, Bits[29:24] The default value is 0 (or divide by 1). Rev. G | Page 80 of 111 Data Sheet AD9548 Table 74. Q3 Divider1 Address 0x0414 0x0415 0x0416 0x0417 1 Bits [7:0] [7:0] [7:0] [7:6] [5:0] Bit Name Q3 Description Q3 divider, Bits[7:0] Q3 divider, Bits[15:8] Q3 divider, Bits[23:16] Unused Q3 Q3 divider, Bits[29:24] The default value is 0 (or divide by 1). REFERENCE INPUT CONFIGURATION (REGISTER 0x0500 TO REGISTER 0x0507) Table 75. Reference Power-Down When all bits are set, the reference receiver section enters a deep sleep mode. Address 0x0500 Bits [7] Bit Name Ref DD power-down [6] Ref D power-down [5] Ref CC power-down [4] Ref C power-down [3] Ref BB power-down [2] Ref B power-down [1] Ref AA power-down [0] Ref A power-down Description REF DD input receiver power-down 0 (default) = normal operation 1 = power-down REF D input receiver power-down 0 (default) = normal operation 1 = power-down REF CC input receiver power-down 0 (default) = normal operation 1 = power-down REF C input receiver power-down 0 (default) = normal operation 1 = power-down REF BB input receiver power-down 0 (default) = normal operation 1 = power-down REF B input receiver power-down 0 (default) = normal operation 1 = power-down REF AA input receiver power-down 0 (default) = normal operation 1 = power-down REF A input receiver power-down 0 (default) = normal operation 1 = power-down Rev. G | Page 81 of 111 AD9548 Data Sheet Table 76. Reference Logic Family Address 0x0501 0x0502 Bits [7:6] Bit Name Ref BB logic family [5:4] Ref B logic family [3:2] [1:0] [7:6] [5:4] [3:2] [1:0] Ref AA logic family Ref A logic family Ref DD logic family Ref D logic family Ref CC logic family Ref C logic family Description Select the logic family for the REF BB input receiver (ignored if Bits[5:4] = 00). 00 (default) = disabled. 01 = 1.2 V to 1.5 V CMOS. 10 = 1.8 V to 2.5 V CMOS. 11 = 3.0 V to 3.3 V CMOS. Select logic family for REF B input receiver. 00 (default) = differential (REFB/BB is positive/negative input). 01 = 1.2 V to 1.5 V CMOS. 10 = 1.8 V to 2.5 V CMOS. 11 = 3.0 V to 3.3 V CMOS. The same as Register 0501, Bits[7:6] but for REF AA. The same as Register 0501, Bits[5:4] but for REF A. The same as Register 0501, Bits[7:6] but for REF DD. The same as Register 0501, Bits[5:4] but for REF D. The same as Register 0501, Bits[7:6] but for REF CC. The same as Register 0501, Bits[5:4] but for REF C. Table 77. Manual Reference Profile Selection Address 0x0503 0x0504 0x0505 0x0506 Bits [7] Bit Name Enable Ref AA manual profile [6:4] Ref AA manual profile [3] [2:0] [7] [6:4] [3] [2:0] [7] [6:4] [3] [2:0] [7] [6:4] [3] [2:0] Enable Ref A manual profile Ref A manual profile Enable Ref BB manual profile Ref BB manual profile Enable Ref B manual profile Ref B manual profile Enable Ref CC manual profile Ref CC manual profile Enable Ref C manual profile Ref C manual profile Enable Ref DD M manual profile Ref DD manual profile Enable Ref D manual profile Ref D manual profile Description Select manual or automatic reference profile assignment for REF AA 0 (default) = automatic 1 = manual Manual profile assignment 000 (default) = Profile 0 001 = Profile 1 010 = Profile 2 011 = Profile 3 100 = Profile 4 101 = Profile 5 110 = Profile 6 111 = Profile 7 Same as Register 0503, Bit 7 but for REF A Same as Register 0503, Bits[6:4] but for REF A Same as Register 0503, Bit 7 but for REF B Same as Register 0503, Bits[6:4] but for REF BB Same as Register 0503, Bit 7 but for REF B Same as Register 0503, Bits[6:4] but for REF B Same as Register 0503, Bit 7 but for REF CC Same as Register 0503, Bits[6:4] but for REF CC Same as Register 050, Bit 7 but for REF C Same as Register 0503, Bits[6:4] but for REF C Same as Register 0503, Bit 7 but for REF DD Same as Register 0503, Bits[6:4] but for REF DD Same as Register 0503, Bit 7 but for REF D Same as Register 0503, Bits[6:4] but for REF D Rev. G | Page 82 of 111 Data Sheet AD9548 Table 78. Phase Build-Out Switching Address 0x0507 Bits [7:3] [2:0] Bit Name Unused Phase master threshold priority Description Threshold priority level (a value of 0 to 7, with 0 (default) being the highest priority level). References with a selection priority value lower than this value are treated as phase masters (see the Profile Registers (Register 0X0600 to Register 0X07FF) section for the selection priority value). PROFILE REGISTERS (REGISTER 0x0600 TO REGISTER 0x07FF) Note that the default value of every bit is 0 for Profile 0 to Profile 7. Register 0x0600 to Register 0x0631—Profile 0 Table 79. Priorities—Profile 0 Address 0x0600 Bits [7] Bit Name Phase lock scale [6] [5:3] Unused Promoted priority [2:0] Selection priority Description Controls the phase lock threshold unit scaling. 0 = picoseconds. 1 = nanoseconds. User assigned priority level (0 to 7) of the reference associated with Profile 0 while that reference is the active reference. The numeric value of the promoted priority must be less than or equal to the numeric value of the selection priority. User assigned priority level (0 to 7) of the reference associated with Profile 0, which ranks that reference relative to the others. Table 80. Reference Period—Profile 0 Address 0x0601 0x0602 0x0603 0x0604 0x0605 0x0606 0x0607 Bits [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:2] [1:0] Bit Name Reference period (in femtoseconds) Description Nominal reference period, Bits[7:0] Nominal reference period, Bits[15:8] Nominal reference period, Bits[23:16] Nominal reference period, Bits[31:24] Nominal reference period, Bits[39:32] Nominal reference period, Bits[47:40] Unused Reference period Nominal reference period, Bits[49:48] Table 81. Tolerance—Profile 0 Address 0x0608 0x0609 Bits [7:0] [7:0] [7:4] [3:0] [7:0] [7:0] [7:4] [3:0] 0x060A 0x060B 0x060C 0x060D Bit Name Inner tolerance Description Inner tolerance, Bits[7:0] Inner tolerance, Bits[15:8] Unused Inner tolerance Outer tolerance Inner tolerance, Bits[19:16] Outer tolerance, Bits[7:0] Outer tolerance, Bits[5:8] Unused Outer tolerance Outer tolerance, Bits[19:16] Table 82. Validation Timer—Profile 0 Address 0x060E 0x060F Bits [7:0] [7:0] Bit Name Validation timer (in milliseconds) Description Validation timer, Bits[7:0] Validation timer, Bits[15:8] Table 83. Redetect Timer—Profile 0 Address 0x0610 0x0611 Bits [7:0] [7:0] Bit Name Redetect timer (in milliseconds) Rev. G | Page 83 of 111 Description Redetect timer, Bits[7:0] Redetect timer, Bits[15:8] AD9548 Data Sheet Table 84. Digital Loop Filter Coefficients—Profile 01 Address 0x0612 0x0613 0x0614 0x0615 0x0616 0x617 0x0618 0x0619 0x061A 0x061B 0x061C 0x061D 1 Bits [7:0] [7:0] [7:6] [5:0] [7:1] [0] [7:0] [7] [6:2] [1:0] [7:0] [7:0] [7:6] [5:1] [0] [7:0] [7] [6:0] [7:4] [3:0] Bit Name Alpha-0 linear Description Alpha-0 coefficient linear, Bits[7:0] Alpha-0 coefficient linear, Bits[15:8] Alpha-2 coefficient exponent, Bits[1:0] Alpha-1 coefficient exponent, Bits[5:0] Beta-0 coefficient linear, Bits[6:0] Alpha-2 coefficient exponent, Bit 2 Beta-0 coefficient linear, Bits[14:7] Alpha-2 exponent Alpha-1 exponent Beta-0 linear Alpha-2 exponent Beta-0 linear Unused Beta-1 exponent Beta-0 linear Gamma-0 linear Beta-1 coefficient exponent, Bits[4:0] Beta-0 coefficient linear, Bits[16:15] Gamma-0 coefficient linear, Bits[7:0] Gamma -0 coefficient linear, Bits[15:8] Unused Gamma-1 exponent Gamma-0 linear Delta-0 linear Delta-1 exponent Delta-0 linear Alpha-3 exponent Delta-1 exponent Gamma-1 coefficient exponent, Bits[4:0] Gamma-0 coefficient linear, Bit 16 Delta-0 coefficient linear, Bits[7:0] Delta-1 coefficient exponent, Bit 0 Delta-0 coefficient linear, Bits[14:8] Alpha-3 coefficient exponent, Bits[3:0] Delta-1 coefficient exponent, Bits[4:1] The digital loop filter coefficients (α, β, γ, and δ) have the general form: x(2y), where x is the linear component and y is the exponential component of the coefficient. The value of the linear component (x) constitutes a fraction, where 0 ≤ x < 1. The exponential component (y) is an integer. See the Calculating Digital Filter Coefficients section for details. Table 85. R-Divider—Profile 01 Address 0x061E 0x061F 0x0620 0x0621 1 Bits [7:0] [7:0] [7:0] [7:6] [5:0] Bit Name R Unused R Description R, Bits[7:0] R, Bits[15:8] R, Bits[23:16] R, Bits[29:24] The value stored in the R-divider register yields an actual divide ratio of one more than the programmed value. Table 86. S-Divider—Profile 01 Address 0x0622 0x0623 0x0624 0x0625 1 Bits [7:0] [7:0] [7:0] [7:6] [5:0] Bit Name S Unused S Description S, Bits[7:0] S, Bits[15:8] S, Bits[23:16] S, Bits[29:24] The value stored in the S-divider register yields an actual divide ratio of one more than the programmed value. Furthermore, the value of S must be at least 7. Rev. G | Page 84 of 111 Data Sheet AD9548 Table 87. Fractional Feedback Divider—Profile 0 Address 0x0626 0x0627 Bits [7:0] [7:4] [3:2] [1:0] [7:6] [5:0] 0x0628 Bit Name V U Unused V Unused U Description V, Bits[7:0] U, Bits[3:0] V, Bits[9:8] U, Bits[9:4] Table 88. Lock Detectors—Profile 0 Address 0x0629 0x062A 0x062B 0x062C 0x062D 0x062E 0x062F 0x0630 0x0631 Bits [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] Bit Name Phase lock threshold (units determined by Register 0x0600[7]) Phase lock fill rate Phase lock drain rate Frequency lock thresh-old (in picoseconds) Frequency lock fill rate Frequency lock drain rate Description Phase lock threshold, Bits[7:0] Phase lock threshold, Bits[15:8] Phase lock fill rate, Bits[7:0] Phase lock drain rate, Bits[7:0] Frequency lock threshold, Bits[7:0] Frequency lock threshold, Bits[15:8] Frequency lock threshold, Bits[23:16] Frequency lock fill rate, Bits[7:0] Frequency lock drain rate, Bits[7:0] Register 0x0632 to Register 0x067F—Profile 1 Table 89. Priorities—Profile 1 Address 0x0632 Bits [7] Bit Name Phase lock scale [6] [5:3] Unused Promoted priority [2:0] Selection priority Description Controls the phase lock threshold unit scaling. 0 = picoseconds. 1 = nanoseconds. User assigned priority level (0 to 7) of the reference associated with Profile 1 while that reference is the active reference. The numeric value of the promoted priority must be less than or equal to the numeric value of the selection priority. User assigned priority level (0 to 7) of the reference associated with Profile 1, which ranks that reference relative to the others. Table 90. Reference Period—Profile 1 Address 0x0633 0x634 0x0635 0x0636 0x0637 0x0638 0x0639 Bits [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:2] [1:0] Bit Name Reference period (in femtoseconds) Unused Reference period Description Nominal reference period, Bits[7:0] Nominal reference period, Bits[15:8] Nominal reference period, Bits[23:16] Nominal reference period, Bits[31:24] Nominal reference period, Bits[39:32] Nominal reference period, Bits[47:40] Nominal reference period, Bits[49:48] Rev. G | Page 85 of 111 AD9548 Data Sheet Table 91. Tolerance—Profile 1 Address 0x063A 0x063B 0x063C Bits [7:0] [7:0] [7:4] [3:0] [7:0] [7:0] [7:4] [3:0] 0x063D 0x063E 0x063F Bit Name Inner tolerance Description Inner tolerance, Bits[7:0] Inner tolerance, Bits[15:8] Unused Inner tolerance Outer tolerance Inner tolerance, Bits[19:16] Outer tolerance, Bits[7:0] Outer tolerance, Bits[15:8] Unused Outer tolerance Outer tolerance, Bits[19:16] Table 92. Validation Timer—Profile 1 Address 0x0640 0x0641 Bits [7:0] [7:0] Bit Name Validation timer (in milliseconds) Description Validation timer, Bits[7:0] Validation timer, Bits[15:8] Table 93. Redetect Timer—Profile 1 Address 0x0642 0x0643 Bits [7:0] [7:0] Bit Name Redetect timer (in milliseconds) Description Redetect timer, Bits[7:0] Redetect timer, Bits[15:8] Table 94. Digital Loop Filter Coefficients—Profile 11 Address 0x0644 0x0645 0x0646 0x0647 0x0648 0x0649 0x064A 0x064B 0x064C 0x064D 0x064E 0x064F 1 Bits [7:0] [7:0] [7:6] [5:0] [7:1] [0] [7:0] [7] [6:2] [1:0] [7:0] [7:0] [7:6] [5:1] [0] [7:0] [7] [6:0] [7:4] [3:0] Bit Name Alpha-0 linear Alpha-2 exponent Alpha-1 exponent Beta -0 linear Alpha-2 exponent Beta-0 linear Unused Beta-1 exponent Beta-0 linear Gamma-0 linear Unused Gamma-1 exponent Gamma-0 linear Delta-0 linear Delta-1 exponent Delta-0 linear Alpha-3 exponent Delta-1 exponent Description Alpha-0 coefficient linear, Bits[7:0] Alpha-0 coefficient linear, Bits[15:8] Alpha-2 coefficient exponent, Bits[1:0] Alpha-1 coefficient exponent, Bits[5:0] Beta-0 coefficient linear, Bits[6:0] Alpha-2 coefficient exponent, Bit 2 Beta-0 coefficient linear, Bits[14:7] Beta-1 coefficient exponent, Bits[4:0] Beta-0 coefficient linear, Bits[16:15] Gamma-0 coefficient linear, Bits[7:0] Gamma-0 coefficient linear, Bits[15:8] Gamma-1 coefficient exponent, Bits[4:0] Gamma-0 coefficient linear, Bit 16 Delta-0 coefficient linear, Bits[7:0] Delta-1 coefficient exponent, Bit 0 Delta-0 coefficient linear, Bits[14:8] Alpha-3 coefficient exponent, Bits[3:0] Delta-1 coefficient exponent, Bits[4:1] The digital loop filter coefficients (α, β, γ, and δ) have the general form: x(2y), where x is the linear component and y is the exponential component of the coefficient. The value of the linear component (x) constitutes a fraction, where 0 ≤ x < 1. The exponential component (y) is an integer. See the Calculating Digital Filter Coefficients section for details. Rev. G | Page 86 of 111 Data Sheet AD9548 Table 95. R-Divider—Profile 11 Address 0x0650 0x0651 0x0652 0x0653 1 Bits [7:0] [7:0] [7:0] [7:6] [5:0] Bit Name R Unused R Description R, Bits[7:0] R, Bits[15:8] R, Bits[23:16] R, Bits[29:24] The value stored in the R-divider register yields an actual divide ratio of one more than the programmed value. Table 96. S-Divider—Profile 11 Address 0x0654 0x0655 0x0656 Bits [7:0] [7:0] [7:0] [7:6] [5:0] 0x0657 1 Bit Name S Unused S Description S, Bits[7:0] S, Bits[15:8] S, Bits[23:16] S, Bits[29:24] The value stored in the S-divider register yields an actual divide ratio of one more than the programmed value. Furthermore, the value of S must be at least 7. Table 97. Fractional Feedback Divider—Profile 1 Address 0x0658 0x0659 Bits [7:0] [7:4] [3:2] [1:0] [7:6] [5:0] 0x065A Bit Name V U Unused V Unused U Description V, Bits[7:0] U, Bits[3:0] V, Bits[9:8] U, Bits[9:4] Table 98. Lock Detectors—Profile 1 Address 0x065B 0x065C 0x065D 0x065E 0x065F 0x0660 0x0661 0x0662 0x0663 0x0664 to 0x067F Bits [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] Bit Name Phase lock threshold (units determined by Register 0x0632[7]) Phase lock fill rate Phase lock drain rate Frequency lock threshold (in picoseconds) Frequency lock fill rate Frequency lock drain rate Unused Rev. G | Page 87 of 111 Description Phase lock threshold, Bits[7:0] Phase lock threshold, Bits[15:8] Phase lock fill rate, Bits[7:0] Phase lock drain rate, Bits[7:0] Frequency lock threshold, Bits[7:0] Frequency lock threshold, Bits[15:8] Frequency lock threshold, Bits[23:16] Frequency lock fill rate, Bits[7:0] Frequency lock drain rate, Bits[7:0] AD9548 Data Sheet Register 0x0680 to Register 0x06B1—Profile 2 Table 99. Priorities—Profile 2 Address 0x0680 Bits [7] Bit Name Phase lock scale [6] [5:3] Unused Promoted priority [2:0] Selection priority Description Controls the phase lock threshold unit scaling. 0 = picoseconds. 1 = nanoseconds. User assigned priority level (0 to 7) of the reference associated with Profile 2 while that reference is the active reference. The numeric value of the promoted priority must be less than or equal to the numeric value of the selection priority. User assigned priority level (0 to 7) of the reference associated with Profile 2, which ranks that reference relative to the others. Table 100. Reference Period—Profile 2 Address 0x0681 0x0682 0x0683 0x0684 0x0685 0x0686 0x0687 Bits [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:2] [1:0] Bit Name Reference period (in femtoseconds) Description Nominal reference period, Bits[7:0] Nominal reference period, Bits[15:8] Nominal reference period, Bits[23:16] Nominal reference period, Bits[31:24] Nominal reference period, Bits[39:32] Nominal reference period, Bits[47:40] Unused Reference period Nominal reference period, Bits[49:48] Table 101. Tolerance—Profile 2 Address 0x0688 0x0689 0x068A Bits [7:0] [7:0] [7:4] [3:0] [7:0] [7:0] [7:4] [3:0] 0x068B 0x068C 0x068D Bit Name Inner tolerance Description Inner tolerance, Bits[7:0] Inner tolerance, Bits[15:8] Unused Inner tolerance Outer tolerance Inner tolerance, Bits[19:16] Outer tolerance, Bits[7:0] Outer tolerance, Bits[15:8] Unused Outer tolerance Outer tolerance, Bits[19:16] Table 102. Validation Timer—Profile 2 Address 0x068E 0x068F Bits [7:0] [7:0] Bit Name Validation timer (in milliseconds) Description Validation timer, Bits[7:0] Validation timer, Bits[15:8] Table 103. Redetect Timer—Profile 2 Address 0x0690 0x0691 Bits [7:0] [7:0] Bit Name Redetect timer (in milliseconds) Rev. G | Page 88 of 111 Description Redetect timer, Bits[7:0] Redetect timer, Bits[15:8] Data Sheet AD9548 Table 104. Digital Loop Filter Coefficients—Profile 21 Address 0x0692 0x0693 0x0694 0x0695 0x0696 0x0697 0x0698 0x0699 0x069A 0x069B 0x069C 0x069D 1 Bits [7:0] [7:0] [7:6] [5:0] [7:1] [0] [7:0] [7] [6:2] [1:0] [7:0] [7:0] [7:6] [5:1] [0] [7:0] [7] [6:0] [7:4] [3:0] Bit Name Alpha-0 linear Description Alpha-0 coefficient linear, Bits[7:0] Alpha-0 coefficient linear, Bits[15:8] Alpha-2 coefficient exponent, Bits[1:0] Alpha-1 coefficient exponent, Bits[5:0] Beta-0 coefficient linear, Bits[6:0] Alpha-2 coefficient exponent, Bit 2 Beta-0 coefficient linear, Bits[14:7] Alpha-2 exponent Alpha-1 exponent Beta-0 linear Alpha-2 exponent Beta 0-linear Unused Beta-1 exponent Beta-0 linear Gamma-0 linear Beta-1 coefficient exponent, Bits[4:0] Beta-0 coefficient linear, Bits[16:15] Gamma-0 coefficient linear, Bits[7:0] Gamma-0 coefficient linear, Bits[15:8] Unused Gamma-1 exponent Gamma-0 linear Delta-0 linear Delta-1 exponent Delta-0 linear Alpha-3 exponent Delta-1 exponent Gamma-1 coefficient exponent, Bits[4:0] Gamma-0 coefficient linear, Bit 6 Delta-0 coefficient linear, Bits[7:0] Delta-1 coefficient exponent, Bit 0 Delta-0 coefficient linear, Bits[14:8] Alpha-3 coefficient exponent, Bits[3:0] Delta-1 coefficient exponent, Bits[4:1] The digital loop filter coefficients (α, β, γ, and δ) have the general form: x(2y), where x is the linear component and y is the exponential component of the coefficient. The value of the linear component (x) constitutes a fraction, where 0 ≤ x < 1. The exponential component (y) is an integer. See the Calculating Digital Filter Coefficients section for details. Table 105. R-Divider—Profile 21 Address 0x069E 0x069F 0x06A0 0x06A1 1 Bits [7:0] [7:0] [7:0] [7:6] [5:0] Bit Name R Unused R Description R, Bits[7:0] R, Bits[15:8] R, Bits[23:16] R, Bits[29:24] The value stored in the R-divider register yields an actual divide ratio of one more than the programmed value. Table 106. S-Divider—Profile 21 Address 0x06A2 0x06A3 0x06A4 0x06A5 1 Bits [7:0] [7:0] [7:0] [7:6] [5:0] Bit Name S Unused S Description S, Bits[7:0] S, Bits[15:8] S, Bits[23:16] S, Bits[29:24] The value stored in the S-divider register yields an actual divide ratio of one more than the programmed value. Furthermore, the value of S must be at least 7. Table 107. Fractional Feedback Divider—Profile 2 Address 0x06A6 0x06A7 0x06A8 Bits [7:0] [7:4] [3:2] [1:0] [7:6] [5:0] Bit Name V U Unused V Unused U Rev. G | Page 89 of 111 Description V, Bits[7:0] U, Bits[3:0] V, Bits[9:8] U, Bits[9:4] AD9548 Data Sheet Table 108. Lock Detectors—Profile 2 Address 0x06A9 0x06AA 0x06AB 0x06AC 0x06AD 0x06AE 0x06AF 0x06B0 0x06B1 Bits [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] Bit Name Phase lock threshold (units determined by Register 0x0680[7]) Phase lock fill rate Phase lock drain rate Frequency lock thresh-old (in picoseconds) Frequency lock fill rate Frequency lock drain rate Description Phase lock threshold, Bits[7:0] Phase lock threshold, Bits[15:8] Phase lock fill rate, Bits[7:0] Phase lock drain rate, Bits[7:0] Frequency lock threshold, Bits[7:0] Frequency lock threshold, Bits[15:8] Frequency lock threshold, Bits[23:16] Frequency lock fill rate, Bits[7:0] Frequency lock drain rate, Bits[7:0] Register 0x06B2 to Register 0x07FF—Profile 3 Table 109. Priorities—Profile 3 Address 0x06B2 Bits [7] Bit Name Phase lock scale [6] [5:3] Unused Promoted priority [2:0] Selection priority Description Controls the phase lock threshold unit scaling. 0 = picoseconds. 1 = nanoseconds. User assigned priority level (0 to 7) of the reference associated with Profile 3 while that reference is the active reference. The numeric value of the promoted priority must be less than or equal to the numeric value of the selection priority. User assigned priority level (0 to 7) of the reference associated with Profile 3, which ranks that reference relative to the others. Table 110. Reference Period—Profile 3 Address 0x06B3 0x06B4 0x06B5 0x06B6 0x06B7 0x06B8 0x06B9 Bits [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:2] [1:0] Bit Name Reference period (in femtoseconds) Description Nominal reference period, Bits[7:0] Nominal reference period, Bits[15:8] Nominal reference period, Bits[23:16] Nominal reference period, Bits[31:24] Nominal reference period, Bits[39:32] Nominal reference period, Bits[47:40] Unused Reference period Nominal reference period, Bits[49:48] Table 111. Tolerance—Profile 3 Address 0x06BA 0x06BB 0x06BC Bits [7:0] [7:0] [7:4] [3:0] [7:0] [7:0] [7:4] [3:0] 0x06BD 0x06BE 0x06BF Bit Name Inner tolerance Description Inner tolerance, Bits[7:0] Inner tolerance, Bits[15:8] Unused Inner tolerance Outer tolerance Inner tolerance, Bits[19:16] Outer tolerance, Bits[7:0] Outer tolerance, Bits[15:8] Unused Outer tolerance Outer tolerance, Bits[19:16] Table 112. Validation Timer—Profile 3 Address 0x06C0 0x06C1 Bits [7:0] [7:0] Bit Name Validation timer (in milliseconds) Rev. G | Page 90 of 111 Description Validation timer, Bits[7:0] Validation timer, Bits[15:8] Data Sheet AD9548 Table 113. Redetect Timer—Profile 3 Address 0x06C2 0x06C3 Bits [7:0] [7:0] Bit Name Redetect timer (in milliseconds) Description Redetect timer, Bits[7:0] Redetect timer, Bits[15:8] Table 114. Digital Loop Filter Coefficients—Profile 31 Address 0x06C4 0x06C5 0x06C6 0x06C7 0x06C8 0x06C9 0x06CA 0x06CB 0x06CC 0x06CD 0x06CE 0x06CF 1 Bits [7:0] [7:0] [7:6] [5:0] [7:1] [0] [7:0] [7] [6:2] [1:0] [7:0] [7:0] [7:6] [5:1] [0] [7:0] [7] [6:0] [7:4] [3:0] Bit Name Alpha-0 linear Description Alpha-0 coefficient linear, Bits[7:0] Alpha-0 coefficient linear, Bits[15:8] Alpha-2 coefficient exponent, Bits[1:0] Alpha-1 coefficient exponent, Bits[5:0] Beta-0 coefficient linear, Bits[6:0] Alpha-2 coefficient exponent, Bit 2 Beta-0 coefficient linear, Bits[14:7] Alpha-2 exponent Alpha-1 exponent Beta-0 linear Alpha-2 exponent Beta-0 linear Unused Beta-1 exponent Beta-0 linear Gamma-0 linear Beta-1 coefficient exponent, Bits[4:0] Beta-0 coefficient linear, Bits[16:15] Gamma-0 coefficient linear, Bits[7:0] Gamma-0 coefficient linear, Bits[15:8] Unused Gamma-1 exponent Gamma-0 linear Delta-0 linear Delta-1 exponent Delta-0 linear Alpha-3 exponent Delta-1 exponent Gamma-1 coefficient exponent, Bits[4:0] Gamma-0 coefficient linear, Bit 16 Delta-0 coefficient linear, Bits[7:0] Delta-1 coefficient exponent, Bit 0 Delta-0 coefficient linear, Bits[14:8] Alpha-3 coefficient exponent, Bits[3:0] Delta-1 coefficient exponent, Bits[4:1] The digital loop filter coefficients (α, β, γ, and δ) have the general form: x(2y), where x is the linear component and y is the exponential component of the coefficient. The value of the linear component (x) constitutes a fraction, where 0 ≤ x < 1. The exponential component (y) is an integer. See the Calculating Digital Filter Coefficients section for details. Table 115. R Divider—Profile 31 Address 0x06D0 0x06D1 0x06D2 0x06D3 1 Bits [7:0] [7:0] [7:0] [7:6] [5:0] Bit Name R Unused R Description R, Bits[7:0] R, Bits[15:8] R, Bits[23:16] R, Bits[29:24] The value stored in the R-divider register yields an actual divide ratio of one more than the programmed value. Table 116. S Divider—Profile 31 Address 0x06D4 0x06D5 0x06D6 0x06D7 1 Bits [7:0] [7:0] [7:0] [7:6] [5:0] Bit Name S Unused S Description S, Bits[7:0] S, Bits[15:8] S, Bits[23:16] S, Bits[29:24] The value stored in the S-divider register yields an actual divide ratio of one more than the programmed value. Furthermore, the value of S must be at least 7. Rev. G | Page 91 of 111 AD9548 Data Sheet Table 117. Fractional Feedback Divider—Profile 3 Address 0x06D8 0x06D9 Bits [7:0] [7:4] [3:2] [1:0] [7:6] [5:0] 0x06DA Bit Name V U Unused V Unused U Description V, Bits[7:0] U, Bits[3:0] V, Bits[9:8] U, Bits[9:4] Table 118. Lock Detectors—Profile 3 Address 0x06DB 0x06DC 0x06DD 0x06DE 0x06DF 0x06E0 0x06E1 0x06E2 0x06E3 0x06E4 to 0x06FF Bits [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] Bit Name Phase lock threshold (units determined by Register 0x06B2[7]) Phase lock fill rate Phase lock drain rate Frequency lock thresh-old (in picoseconds) Frequency lock fill rate Frequency lock drain rate Unused Description Phase lock threshold, Bits[7:0] Phase lock threshold, Bits[15:8] Phase lock fill rate, Bits[7:0] Phase lock drain rate, Bits[7:0] Frequency lock threshold, Bits[7:0] Frequency lock threshold, Bits[15:8] Frequency lock threshold, Bits[23:16] Frequency lock fill rate, Bits[7:0] Frequency lock drain rate, Bits[7:0] Register 0x0700 to Register 0x07FF—Profile 4 to Profile 7 Profile 4 (Register 0x0700 to Register 0x0731) is identical to Profile 0 (Register 0x0600 to Register 0x0631). Profile 5 (Register 0x0732 to Register 0x077F) is identical to Profile 1 (Register 0x0632 to Register 0x067F). Profile 6 (Register 0x0780 to Register 0x07B1) is identical to Profile 2 (Register 0x0680 to Register 0x06B1). Profile 7 (Register 0x07B2 to Register 0x07FF) is identical to Profile 3 (Register 0x06B2 to Register 0x06FF). OPERATIONAL CONTROLS (REGISTER 0x0A00 TO REGISTER 0x0A10) Table 119. General Power-Down Address 0x0A00 Bits [7] Bit Name Reset sans reg map [6] [5] Unused SYSCLK power-down [4] Reference power-down [3] TDC power-down [2] DAC power-down [1] Dist power-down [0] Full power-down Description Reset internal hardware but retain programmed register values. 0 (default) = normal operation. 1 = reset. Place SYSCLK input and PLL in deep sleep mode. 0 (default) = normal operation. 1 = power-down. Place reference clock inputs in deep sleep mode. 0 (default) = normal operation. 1 = power-down. Place the time-to-digital converter in deep sleep mode. 0 (default) = normal operation. 1 = power-down. Place the DAC in deep sleep mode. 0 (default) = normal operation. 1 = power-down. Place the clock distribution outputs in deep sleep mode. 0 (default) = normal operation. 1 = power-down. Place the entire device in deep sleep mode. 0 (default) = normal operation. 1 = power-down. Rev. G | Page 92 of 111 Data Sheet AD9548 Table 120. Loop Mode Address 0x0A01 Bits [7] [6] Bit Name Unused User holdover [5] User free-run [4:3] User selection mode [2:0] User reference selection Description Force the device into holdover mode. 0 (default) = normal operation. 1 = force device into holdover mode. The device behaves as though all input references are faulted. Force the device into free-run mode. 0 (default) = normal operation. 1 = force device into free-run mode. The free running frequency tuning word register specifies the DDS output frequency. Note that, when the user free-run bit is set, it overrides the user holdover bit. Select the operating mode of the reference switching state machine. 00 (default) = automatic mode. The fully automatic priority-based algorithm selects the active reference (Bits[2:0] are ignored). 01 = fallback mode. The active reference is the user reference (Bits[2:0]) as long as it is valid. Otherwise, use the fully automatic priority-based algorithm to select the active reference. 10 = holdover mode. The active reference is the user reference (Bits[2:0]) as long as it is valid. Otherwise, enter holdover mode. 11 = manual mode. The active reference is always the user reference (Bits[2:0]). When using manual mode, be sure that the reference declared as the user reference (Bits[2:0]) is programmed for manual reference-to-profile assignment in the appropriate manual reference profile selection register (Address 0503 to Address 0506). Input reference when user selection mode = 01, 10, or 11. 000 (default) = Input Reference A. 001 = Input Reference AA. 010 = Input Reference B. 011 = Input Reference BB. 100 = Input Reference C. 101 = Input Reference CC. 110 = Input Reference D. 111 = Input Reference DD. Table 121. Cal/Sync Address 0x0A02 Bits [7:2] [1] [0] Bit Name Unused Sync distribution Calibrate system clock Description Setting this bit (default = 0) initiates synchronization of the clock distribution output. While this bit = 1, the clock distribution output stalls. Synchronization occurs on the 1 to 0 transition of this bit. A 0 to 1 transition on this bit (default = 0), followed by an IO_UPDATE, initiates an internal calibration of the SYSCLK PLL (assuming it is enabled). The calibration routine automatically selects the proper VCO frequency band and signal amplitude. The internal system clock stalls during the calibration procedure, disabling the device until the calibration is complete (a few milliseconds). If the user wishes to recalibrate the SYSCLK PLL and this bit is already set to 1, the user must first write a 0 to this bit, issue an IO_UPDATE, write a 1 to this bit, and issue another IO_UPDATE. Rev. G | Page 93 of 111 AD9548 Data Sheet Register 0x0A03—ResetFunc Table 122. Reset Functions1 Address 0x0A03 Bits [7] [6] [5] [4] [3] [2] [1] [0] 1 Bit Name Unused Clear LF Clear CCI Clear phase accumulator Reset auto sync Reset TW history Reset all IRQs Reset watchdog Description Setting this bit (default = 0) clears the digital loop filter (intended as a debug tool). Setting this bit (default = 0) clears the CCI filter (intended as a debug tool). Setting this bit (default = 0) clears DDS phase accumulator (not a recommended action). Setting this bit (default = 0) resets the automatic synchronization logic (see Register 0x0403). Setting this bit (default = 0) resets the tuning word history logic (part of holdover functionality). Setting this bit (default = 0) clears the entire IRQ monitor register (Register 0x0D02 to Register 0x0D09). It is the equivalent of setting all the bits of the IRQ clearing register (Register 0x0A04 to Register 0x0A0B). Setting this bit (default = 0) resets the watchdog timer (see Register 0x0211 to Register 0x0212). If the timer had timed out, it simply starts a new timing cycle. If the timer has not yet timed out, it restarts at time zero without causing a timeout event. Continuously resetting the watchdog timer at intervals less than its timeout period prevents the watchdog timer from generating a timeout event. All bits in this register are autoclearing. Register 0x0A04 to Register 0x0A0B—IRQ Clearing The IRQ clearing registers are identical in format to the IRQ monitor registers (Address 0x0D02 to Address 0x0D09). When set to Logic 1, an IRQ clearing bit resets the corresponding IRQ monitor bit, thereby canceling the interrupt request for the indicated event. The IRQ clearing register is an autoclearing register. Table 123. IRQ Clearing for SYSCLK Address 0x0A04 Bits [7:6] [5] [4] [3:2] [1] [0] Bit Name Unused SYSCLK unlocked SYSCLK locked Unused SYSCLK Cal complete SYSCLK Cal started Description Clears SYSCLK unlocked IRQ Clears SYSCLK locked IRQ Clears SYSCLK calibration complete IRQ Clears SYSCLK calibration started IRQ Table 124. IRQ Clearing for Distribution Sync, Watchdog Timer, and EEPROM Address 0x0A05 Bits [7:4] [3] [2] [1] [0] Bit Name Unused Distribution sync Watchdog timer EEPROM fault EEPROM complete Description Clears distribution sync IRQ Clears watchdog timer IRQ Clears EEPROM fault IRQ Clears EEPROM complete IRQ Table 125. IRQ Clearing for the Digital PLL Address 0x0A06 Bits [7] [6] [5] [4] [3] [2] [1] [0] Bit Name Switching Closed Free-run Holdover Freq unlocked Freq locked Phase unlocked Phase locked Description Clears switching IRQ Clears closed IRQ Clears free-run IRQ Clears holdover IRQ Clears frequency unlocked IRQ Clears frequency locked IRQ Clears phase unlocked IRQ Clears phase locked IRQ Rev. G | Page 94 of 111 Data Sheet AD9548 Table 126. IRQ Clearing for History Update, Frequency Limit, and Phase Slew Limit Address 0x0A07 Bits [7:5] [4] [3] [2] [1] [0] Bit Name Unused History updated Frequency unclamped Frequency clamped Phase slew unlimited Phase slew limited Description Clears history updated IRQ Clears frequency unclamped IRQ Clears frequency clamped IRQ Clears phase slew unlimited IRQ Clears phase slew limited IRQ Table 127. IRQ Clearing for Reference Inputs Address 0x0A08 0x0A09 0x0A0A 0x0A0B Bits [7] [6] [5] [4] [3] [2] [1] [0] [7] [6] [5] [4] [3] [2] [1] [0] [7] [6] [5] [4] [3] [2] [1] [0] [7] [6] [5] [4] [3] [2] [1] [0] Bit Name Ref AA new profile Ref AA validated Ref AA fault cleared Ref AA fault Ref A new profile Ref A validated Ref A fault cleared Ref A fault Ref BB new profile Ref BB validated Ref BB fault cleared Ref BB fault Ref B new profile Ref B validated Ref B fault cleared Ref B fault Ref CC new profile Ref CC validated Ref CC fault cleared Ref CC fault Ref C new profile Ref C validated Ref C fault cleared Ref C fault Ref DD new profile Ref DD validated Ref DD fault cleared Ref DD fault Ref D new profile Ref D validated Ref D fault cleared Ref D fault Description Clears Ref AA new profile IRQ Clears Ref AA validated IRQ Clears Ref AA fault cleared IRQ Clears Ref AA fault IRQ Clears Ref A new profile IRQ Clears Ref A validated IRQ Clears Ref A fault cleared IRQ Clears Ref A fault IRQ Clears Ref BB new profile IRQ Clears Ref BB validated IRQ Clears Ref BB fault cleared IRQ Clears Ref BB fault IRQ Clears Ref B new profile IRQ Clears Ref B validated IRQ Clears Ref B fault cleared IRQ Clears Ref B fault IRQ Clears Ref CC new profile IRQ Clears Ref CC validated IRQ Clears Ref CC fault cleared IRQ Clears Ref CC fault IRQ Clears Ref C new profile IRQ Clears Ref C validated IRQ Clears Ref C fault cleared IRQ Clears Ref C fault IRQ Clears Ref DD new profile IRQ Clears Ref DD validated IRQ Clears Ref DD fault cleared IRQ Clears Ref DD fault IRQ Clears Ref D new profile IRQ Clears Ref D validated IRQ Clears Ref D fault cleared IRQ Clears Ref D fault IRQ Rev. G | Page 95 of 111 AD9548 Data Sheet Table 128. Incremental Phase Offset Control Address 0x0A0C Bits [7:3] [2] [1] [0] Bit Name Unused Reset phase offset Decr phase offset Incr phase offset Description Resets the incremental phase offset to 0. This is an autoclearing bit. Decrements the incremental phase offset by the amount specified in the incremental phase lock offset step size register (Register 0x0314 to Register 0x0315). This is an autoclearing bit. Increments the incremental phase offset by the amount specified in the incremental phase lock offset step size register (Register 0x0314 to Register 0x0315). This is an autoclearing bit. Table 129. Reference Profile Selection State Machine Startup1 Address 0x0A0D 1 Bits [7] [6] [5] [4] [3] [2] [1] [0] Bit Name Detect DD Detect D Detect CC Detect C Detect BB Detect B Detect AA Detect A Description Setting this bit starts the profile selection state machine for Input Reference DD. Setting this bit starts the profile selection state machine for Input Reference D. Setting this bit starts the profile selection state machine for Input Reference CC. Setting this bit starts the profile selection state machine for Input Reference C. Setting this bit starts the profile selection state machine for Input Reference BB. Setting this bit starts the profile selection state machine for Input Reference B. Setting this bit starts the profile selection state machine for Input Reference AA. Setting this bit starts the profile selection state machine for Input Reference A. All bits in this register are autoclearing. Table 130. Reference Validation Override Controls1 Address 0x0A0E Bits [7] Bit Name Force Timeout DD [6] Force Timeout D [5] Force Timeout CC [4] Force Timeout C [3] Force Timeout BB [2] Force Timeout B [1] Force Timeout AA [0] Force Timeout A Description Setting this bit emulates a timeout of the validation timer for Reference DD. This is an autoclearing bit. Setting this bit emulates a timeout of the validation timer for Reference D. This is an autoclearing bit. Setting this bit emulates a timeout of the validation timer for Reference CC. This is an autoclearing bit. Setting this bit emulates a timeout of the validation timer for Reference C. This is an autoclearing bit. Setting this bit emulates a timeout of the validation timer for Reference BB. This is an autoclearing bit. Setting this bit emulates a timeout of the validation timer for Reference B. This is an autoclearing bit. Setting this bit emulates a timeout of the validation timer for Reference AA. This is an autoclearing bit. Setting this bit emulates a timeout of the validation timer for Reference A. This is an autoclearing bit. Rev. G | Page 96 of 111 Data Sheet Address 0x0A0F 0x0A10 1 Bits [7] [6] [5] [4] [3] [2] [1] [0] [7] [6] [5] [4] [3] [2] [1] [0] AD9548 Bit Name Ref Mon Override DD Ref Mon Override D Ref Mon Override CC Ref Mon Override C Ref Mon Override BB Ref Mon Override B Ref Mon Override AA Ref Mon Override A Ref Mon Bypass DD Ref Mon Bypass D Ref Mon Bypass CC Ref Mon Bypass C Ref Mon Bypass BB Ref Mon Bypass B Ref Mon Bypass AA Ref Mon Bypass A Description Overrides the reference monitor REF fault signal for Reference DD (default = 0, not overridden). Overrides the reference monitor REF fault signal for Reference D (default = 0, not overridden). Overrides the reference monitor REF fault signal for Reference CC (default = 0, not overridden). Overrides the reference monitor REF fault signal for Reference C (default = 0, not overridden). Overrides the reference monitor REF fault signal for Reference BB (default = 0, not overridden). Overrides the reference monitor REF fault signal for Reference B (default = 0, not overridden). Overrides the reference monitor REF fault signal for Reference AA (default = 0, not overridden). Overrides the reference monitor REF fault signal for Reference A (default = 0, not overridden). Bypasses the reference monitor for Reference DD (default = 0, not bypassed). Bypasses the reference monitor for Reference D (default = 0, not bypassed). Bypasses the reference monitor for Reference CC (default = 0, not bypassed). Bypasses the reference monitor for Reference C (default = 0, not bypassed). Bypasses the reference monitor for Reference BB (default = 0, not bypassed). Bypasses the reference monitor for Reference B (default = 0, not bypassed). Bypasses the reference monitor for Reference AA (default = 0, not bypassed). Bypasses the reference monitor for Reference A (default = 0, not bypassed). See Figure 36 for details. CLOCK PART SERIAL ID (REGISTER 0x0C00 TO REGISTER 0x0C07) User programmable EEPROM ID registers. Table 131. User Defined Identification Registers Address 0x0C00 Bits [7:0] 0x0C01 [7:0] 0x0C02 [7:0] 0x0C03 [7:0] 0x0C04 [7:0] 0x0C05 [7:0] 0x0C06 [7:0] 0x0C07 [7:0] Bit Name User scratch pad[7:0] User scratch pad[15:8] User scratch pad[23:16] User scratch pad[31:24] User scratch pad[39:32] User scratch pad[47:40] User scratch pad[55:48] User scratch pad[63:56] Description User programmable EEPROM ID registers. These registers enable users to write a unique code of their choosing to keep track of revisions to the EEPROM register loading. It has no effect on part operation. The default EEPROM storage sequence must be altered to include these registers. See the Programming the EEPROM to Include a Clock Part ID section. 0 = default. STATUS READBACK (REGISTER 0x0D00 TO REGISTER 0x0D19) All bits in Register 0x0D00 to Register 0x0D19 are read only. Register 0x0D00 and Register 0x0D01 require an IO_UPDATE (Register 0x0005 = 0x01) in order to reflect their latest status. Table 132. EEPROM Status Address 0x0D00 Bits [7:3] [2] [1] [0] Bit Name Unused Fault detected Load in progress Save in progress Description An error occurred while saving data to or loading data from the EEPROM. The control logic sets this bit while data is being read from the EEPROM. The control logic sets this bit while data is being written to the EEPROM. Rev. G | Page 97 of 111 AD9548 Data Sheet Table 133. SYSCLK Status Address 0x0D01 Bits [7:5] [4] Bit Name Unused Stable [3:2] [1] Unused Cal in progress Lock detected [0] Description The control logic sets this bit when the device considers the system clock to be stable (see the System Clock Stability Timer section). The control logic holds this bit set while the system clock calibration is in progress. Indicates the status of the system clock PLL. 0 = unlocked. 1 = locked (or the PLL is disabled). Register 0x0D02 to Register 0x0D09—IRQ Monitor If not masked via the IRQ mask register (Address 0x0209 to Address 0x0210), then the appropriate IRQ monitor bit is set to a Logic 1 when the indicated event occurs. These bits can only be cleared via the IRQ clearing register (Address 0x0A04 to Address 0x0A0B), the reset all IRQs bit (Register 0x0A03, Bit 1), or a device reset. Table 134. IRQ Monitor for SYSCLK Address 0x0D02 Bits [7:6] [5] [4] [3:2] [1] [0] Bit Name Unused SYSCLK unlocked SYSCLK locked Unused SYSCLK Cal complete SYSCLK Cal started Description Indicates a SYSCLK PLL state transition from locked to unlocked Indicates a SYSCLK PLL state transition from unlocked to locked Indicates that SYSCLK calibration has completed Indicates that SYSCLK calibration has begun Table 135. IRQ Monitor for Distribution Sync, Watchdog Timer, and EEPROM Address 0x0D03 Bits [7:4] [3] [2] [1] [0] Bit Name Unused Distribution sync Watchdog timer EEPROM fault EEPROM complete Description Indicates a distribution sync event Indicates expiration of the watchdog timer Indicates a fault during an EEPROM load or save operation Indicates successful completion of an EEPROM load or save operation Table 136. IRQ Monitor for the Digital PLL Address 0x0D04 Bits [7] [6] [5] [4] [3] [2] [1] [0] Bit Name Switching Closed Free-run Holdover Freq unlocked Freq locked Phase unlocked Phase locked Description Indicates that the DPLL is switching to a new reference Indicates that the DPLL has entered closed-loop operation Indicates that the DPLL has entered free-run mode Indicates that the DPLL has entered holdover mode Indicates that the DPLL lost frequency lock Indicates that the DPLL has acquired frequency lock Indicates that the DPLL lost phase lock Indicates that the DPLL has acquired phase lock Table 137. IRQ Monitor for History Update, Frequency Limit, and Phase Slew Limit Address 0x0D05 Bits [7:5] [4] [3] [2] [1] [0] Bit Name Unused History updated Freq unclamped Freq clamped Phase slew unlimited Phase slew limited Description Indicates the occurrence of a tuning word history update Indicates a frequency limiter state transition from clamped to unclamped Indicates a frequency limiter state transition from unclamped to clamped Indicates a phase slew limiter state transition from slew limiting to not slew limiting Indicates a phase slew limiter state transition from not slew limiting to slew limiting Rev. G | Page 98 of 111 Data Sheet AD9548 Table 138. IRQ Monitor for Reference Inputs Address 0x0D06 0x0D07 0x0D08 0x0D09 Bits [7] [6] [5] [4] [3] [2] [1] [0] [7] [6] [5] [4] [3] [2] [1] [0] [7] [6] [5] [4] [3] [2] [1] [0] [7] [6] [5] [4] [3] [2] [1] [0] Bit Name Ref AA new profile Ref AA validated Ref AA fault cleared Ref AA fault Ref A new profile Ref A validated Ref A fault cleared Ref A fault Ref BB new profile Ref BB validated Ref BB fault cleared Ref BB fault Ref B new profile Ref B validated Ref B fault cleared Ref B fault Ref CC new profile Ref CC validated Ref CC fault cleared Ref CC fault Ref C new profile Ref C validated Ref C fault cleared Ref C fault Ref DD new profile Ref DD validated Ref DD fault cleared Ref DD fault Ref D new profile Ref D validated Ref D fault cleared Ref D fault Description Indicates that Ref AA has switched to a new profile Indicates that Ref AA has been validated Indicates that Ref AA has been cleared of a previous fault Indicates that Ref AA has been faulted Indicates that Ref A has switched to a new profile Indicates that Ref A has been validated Indicates that Ref A has been cleared of a previous fault Indicates that Ref A has been faulted Indicates that Ref BB has switched to a new profile Indicates that Ref BB has been validated Indicates that Ref BB has been cleared of a previous fault Indicates that Ref BB has been faulted Indicates that Ref B has switched to a new profile Indicates that Ref B has been validated Indicates that Ref B has been cleared of a previous fault Indicates that Ref B has been faulted Indicates that Ref CC has switched to a new profile Indicates that Ref CC has been validated Indicates that Ref CC has been cleared of a previous fault Indicates that Ref CC has been faulted Indicates that Ref C has switched to a new profile Indicates that Ref C has been validated Indicates that Ref C has been cleared of a previous fault Indicates that Ref C has been faulted Indicates that Ref DD has switched to a new profile Indicates that Ref DD has been validated Indicates that Ref DD has been cleared of a previous fault Indicates that Ref DD has been faulted Indicates that Ref D has switched to a new profile Indicates that Ref D has been validated Indicates that Ref D has been cleared of a previous fault Indicates that Ref D has been faulted Table 139. DPLL Status Address 0x0D0A Bits [7] [6] [5] [4] [3] [2] [1] [0] Bit Name Offset slew limiting Phase build-out Freq lock Phase lock Loop switching Holdover Active Free running Description The current closed-loop phase offset is rate limited. A phase build-out transition was made to the currently active reference. The DPLL has achieved frequency lock. The DPLL has achieved phase lock. The DPLL is in the process of a reference switchover. The DPLL is in holdover mode. The DPLL is active (that is, operating in a closed-loop condition). The DPLL is free running (that is, operating in an open-loop condition). Rev. G | Page 99 of 111 AD9548 0x0D0B Data Sheet [7] [6] [5:3] Frequency clamped History available Active reference priority [2:0] Active reference The upper or lower frequency tuning word clamp is in effect. There is sufficient tuning word history available for holdover operation. Priority value of the currently active reference. 000 = highest priority. 111 = lowest priority. Index of the currently active reference. 000 = Reference A. 001 = Reference AA. 010 = Reference B. 011 = Reference BB. 100 = Reference C. 101 = Reference CC. 110 = Reference D. 111 = Reference DD. Table 140. Input Reference Status Address 0x0D0C Bits [7] [3] [2] [1] Bit Name Profile selected Selected profile Valid Fault Fast [0] Slow [6:4] 0x0D0D 0x0D0E 0x0D0F 0x0D10 0x0D11 0x0D12 0x0D13 [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] Description The control logic sets this bit when it assigns Ref A to one of the eight profiles. The index (0 to 7) of the profile assigned to Ref A. Note that these bits are meaningless unless Bit 7 = 1. Ref A is valid for use (it is nonfaulted and its validation timer has expired). Ref A is not valid for use. If Bit 7 = 1, then this bit indicates that the frequency of Ref A is higher than allowed by its profile settings. If Bit 7 = 0, then this bit indicates that the frequency of Ref A is above the maximum input reference frequency supported by the device. If Bit 7 = 1, then this bit indicates that the frequency of Ref A is lower than allowed by its profile settings. If Bit 7 = 0, then this bit indicates that the frequency of Ref A is below the minimum input reference frequency supported by the device. Same as 0D0C but for REF AA instead of REF A. Same as 0D0C but for REF B instead of REF A. Same as 0D0C but for REF BB instead of REF A. Same as 0D0C but for REF C instead of REF A. Same as 0D0C but for REF CC instead of REF A. Same as 0D0C but for REF D instead of REF A. Same as 0D0C but for REF DD instead of REF A. Table 141. Holdover History1 Address 0x0D14 0x0D15 0x0D16 0x0D17 0x0D18 0x0D19 1 Bits [7:0] [7:0] [7:0] [7:0] [7:0] [7:0] Bit Name Holdover history Description Tuning word readback, Bits[7:0] Tuning word readback, Bits[15:8] Tuning word readback, Bits[23:9] Tuning word readback, Bits[31:24] Tuning word readback, Bits[39:32] Tuning word readback, Bits[47:40] These registers contain the current 48-bit DDS frequency tuning word generated by the tuning word history logic. Rev. G | Page 100 of 111 Data Sheet AD9548 NONVOLATILE MEMORY (EEPROM) CONTROL (REGISTER 0x0E00 TO REGISTER 0x0E03) Table 142. EEPROM Control Address 0x0E00 0x0E01 0x0E02 0x0E03 Bits [7:2] [1] Bit Name Unused Half rate mode [0] Write enable [7:5] [4:0] Unused Condition value Unused Save to EEPROM [7:1] [0] [7:2] [1] [0] Unused Load from EEPROM Unused Description EEPROM serial communication rate. 0 (default) = 400 kHz (normal). 1 = 200 kHz. EEPROM write enable/protect. 0 (default) = EEPROM write protected. 1 = EEPROM write enabled. When set to a nonzero value (default = 0), these bits establish the condition for EEPROM downloads. Upload data to the EEPROM based on the EEPROM storage sequence. This is an autoclearing bit. When an EEPROM save/load transfer is complete, wait a minimum of 10 μs before starting the next EEPROM save/load transfer. Download data from the EEPROM. This is an autoclearing bit. When an EEPROM save/load transfer is complete, wait a minimum of 10 μs before starting the next EEPROM save/load transfer. EEPROM STORAGE SEQUENCE (REGISTER 0x0E10 TO REGISTER 0x0E3F) The default settings of Register 0x0E10 to Register 0x0E33 embody a sample scratch pad instruction sequence. The following is a description of the register defaults under the assumption that the controller has been instructed to carry out an EEPROM storage sequence. Table 143. EEPROM Storage Sequence for System Clock Settings Address 0x0E10 Bits [7:0] Bit Name System clock 0x0E11 0x0E12 [7:0] [7:0] System clock 0x0E13 [7:0] I/O update Description The default value of this register is 0x08, which the controller interprets as a data instruction. Its decimal value is 8, which tells the controller to transfer nine bytes of data (8 + 1) beginning at the address specified by the next two bytes. The controller stores 0x08 in the EEPROM and increments the EEPROM address pointer. The default value of these two registers is 0x0100. Note that Register 0x0E11 and Register 0x0E12 are the most significant and least significant bytes of the target address, respectively. Because the previous register contains a data instruction, these two registers define a starting address (in this case, 0x0100). The controller stores 0x0100 in the EEPROM and increments the EEPROM pointer by 2. It then transfers nine bytes from the register map (beginning at Address 0x0100) to the EEPROM and increments the EEPROM address pointer by 10 (nine data bytes and one checksum byte). The nine bytes transferred correspond to the system clock parameters in the register map. The default value of this register is 0x80, which the controller interprets as an I/O update instruction. The controller stores 0x80 in the EEPROM and increments the EEPROM address pointer. Table 144. EEPROM Storage Sequence for System Clock Calibration Address 0x0E14 Bits [7:0] Bit Name SYSCLK calibrate Description The default value of this register is 0xA0, which the controller interprets as a calibrate instruction. The controller stores 0xA0 in the EEPROM and increments the EEPROM address pointer. Rev. G | Page 101 of 111 AD9548 Data Sheet Table 145. EEPROM Storage Sequence for General Configuration Settings Address 0x0E15 Bits [7:0] 0x0E16 0x0E17 [7:0] [7:0] Bit Name General Description The default value of this register is 0x14, which the controller interprets as a data instruction. Its decimal value is 20, which tells the controller to transfer 21 bytes of data (20 + 1) beginning at the address specified by the next two bytes. The controller stores 0x14 in the EEPROM and increments the EEPROM address pointer. General The default value of these two registers is 0x0200. Note that Register 0x0E16 and Register 0x0E17 are the most significant and least significant bytes of the target address, respectively. Because the previous register contains a data instruction, these two registers define a starting address (in this case, 0x0200). The controller stores 0x0200 in the EEPROM and increments the EEPROM pointer by 2. It then transfers 21 bytes from the register map (beginning at Address 0x0200) to the EEPROM and increments the EEPROM address pointer by 22 (21 data bytes and one checksum byte). The 21 bytes transferred correspond to the general configuration parameters in the register map. Table 146. EEPROM Storage Sequence for DPLL Settings Address 0x0E18 Bits [7:0] 0x0E19 0x0E1A [7:0] [7:0] Bit Name DPLL DPLL Description The default value of this register is 0x1B, which the controller interprets as a data instruction. Its decimal value is 27, which tells the controller to transfer 28 bytes of data (27 + 1) beginning at the address specified by the next two bytes. The controller stores 0x1B in the EEPROM and increments the EEPROM address pointer. The default value of these two registers is 0x0300. Note that Register 0x0E19 and Register 0x0E1A are the most significant and least significant bytes of the target address, respectively. Because the previous register contains a data instruction, these two registers define a starting address (in this case, 0x0300). The controller stores 0x0300 in the EEPROM and increments the EEPROM pointer by 2. It then transfers 28 bytes from the register map (beginning at Address 0x0300) to the EEPROM and increments the EEPROM address pointer by 29 (28 data bytes and one checksum byte). The 28 bytes transferred correspond to the DPLL parameters in the register map. Table 147. EEPROM Storage Sequence for Clock Distribution Settings Address 0x0E1B Bits [7:0] Bit Name Clock distribution 0x0E1C 0x0E1D [7:0] [7:0] Clock distribution 0x0E1E [7:0] I/O update Description The default value of this register is 0x19, which the controller interprets as a data instruction. Its decimal value is 25, which tells the controller to transfer 26 bytes of data (25 + 1) beginning at the address specified by the next two bytes. The controller stores 0x19 in the EEPROM and increments the EEPROM address pointer. The default value of these two registers is 0x0400. Note that Register 0x0E1C and Register 0x0x0E1D are the most significant and least significant bytes of the target address, respectively. Because the previous register contains a data instruction, these two registers define a starting address (in this case, 0x0400). The controller stores 0x0400 in the EEPROM and increments the EEPROM pointer by 2. It then transfers 26 bytes from the register map (beginning at Address 0x0400) to the EEPROM and increments the EEPROM address pointer by 27 (26 data bytes and one checksum byte). The 26 bytes transferred correspond to the clock distribution parameters in the register map. The default value of this register is 0x80, which the controller interprets as an I/O update instruction. The controller stores 0x80 in the EEPROM and increments the EEPROM address pointer. Rev. G | Page 102 of 111 Data Sheet AD9548 Table 148. EEPROM Storage Sequence for Reference Input Settings Address 0x0E1F Bits [7:0] Bit Name Reference inputs 0x0E20 0x0E21 [7:0] [7:0] Reference inputs Description The default value of this register is 0x07, which the controller interprets as a data instruction. Its decimal value is 7, which tells the controller to transfer eight bytes of data (7 + 1) beginning at the address specified by the next two bytes. The controller stores 0x07 in the EEPROM and increments the EEPROM address pointer. The default value of these two registers is 0x0500. Note that Register 0x0E20 and Register 0x0E21 are the most significant and least significant bytes of the target address, respectively. Because the previous register contains a data instruction, these two registers define a starting address (in this case, 0x0500). The controller stores 0x0500 in the EEPROM and increments the EEPROM pointer by 2. It then transfers eight bytes from the register map (beginning at Address 0x0500) to the EEPROM and increments the EEPROM address pointer by nine (eight data bytes and one checksum byte). The eight bytes transferred correspond to the reference inputs parameters in the register map. Table 149. EEPROM Storage Sequence for Profile 0 and Profile 1 Settings Address 0x0E22 Bits [7:0] Bit Name Profile 0 and Profile 1 0x0E23 0x0E24 [7:0] [7:0] Profile 0 and Profile 1 Description The default value of this register is 0x63, which the controller interprets as a data instruction. Its decimal value is 99, which this tells the controller to transfer 100 bytes of data (99 + 1) beginning at the address specified by the next two bytes. The controller stores 0x63 in the EEPROM and increments the EEPROM address pointer. The default value of these two registers is 0x0600. Note that Register 0x0E23 and Register 0x0E24 are the most significant and least significant bytes of the target address, respectively. Because the previous register contains a data instruction, these two registers define a starting address (in this case, 0x0600). The controller stores 0x0600 in the EEPROM and increments the EEPROM pointer by 2. It then transfers 100 bytes from the register map (beginning at Address 0x0600) to the EEPROM and increments the EEPROM address pointer by 101 (100 data bytes and one checksum byte). The 99 bytes transferred correspond to the Profile 0 and Profile 1 parameters in the register map. Table 150. EEPROM Storage Sequence for Profile 2 and Profile 3 Settings Address 0x0E25 Bits [7:0] Bit Name Profile 2 and Profile 3 0x0E26 0x0E27 [7:0] [7:0] Profile 2 and Profile 3 Description The default value of this register is 0x63, which the controller interprets as a data instruction. Its decimal value is 99, which tells the controller to transfer 100 bytes of data (99 + 1) beginning at the address specified by the next two bytes. The controller stores 0x63 in the EEPROM and increments the EEPROM address pointer. The default value of these two registers is 0x0680. Note that Register 0x0E26 and Register 0x0E27 are the most significant and least significant bytes of the target address, respectively. Because the previous register contains a data instruction, these two registers define a starting address (in this case, 0x0680). The controller stores 0x0680 in the EEPROM and increments the EEPROM pointer by 2. It then transfers 100 bytes from the register map (beginning at Address 0x0680) to the EEPROM and increments the EEPROM address pointer by 101 (100 data bytes and one checksum byte). The 99 bytes transferred correspond to the Profile 2 and Profile 3 parameters in the register map. Rev. G | Page 103 of 111 AD9548 Data Sheet Table 151. EEPROM Storage Sequence for Profile 4 and Profile 5 Settings Address 0x0E28 Bits [7:0] Bit Name Profile 4 and Profile 5 Description The default value of this register is 0x63, which the controller interprets as a data instruction. Its decimal value is 99, which tells the controller to transfer 100 bytes of data (99 + 1) beginning at the address specified by the next two bytes. The controller stores 0x63 in the EEPROM and increments the EEPROM address pointer. 0x0E29 0x0E2A [7:0] [7:0] Profile 4 and Profile 5 The default value of these two registers is 0x0700. Note that Register 0x0E29 and Register 0x0E2A are the most significant and least significant bytes of the target address, respectively. Because the previous register contains a data instruction, these two registers define a starting address (in this case, 0x0700). The controller stores 0x0700 in the EEPROM and increments the EEPROM pointer by 2. It then transfers 100 bytes from the register map (beginning at Address 0x0700) to the EEPROM and increments the EEPROM address pointer by 101 (100 data bytes and one checksum byte). The 99 bytes transferred correspond to the Profile 4 and Profile 5 parameters in the register map. Table 152. EEPROM Storage Sequence for Profile 6 and Profile 7 Settings Address 0x0E2B Bits [7:0] Bit Name Profile 6 and Profile 7 0x0E2C 0x0E2D [7:0] [7:0] Profile 6 and Profile 7 0x0E2E [7:0] I/O update Description The default value of this register is 0x63, which the controller interprets as a data instruction. Its decimal value is 99, which tells the controller to transfer 100 bytes of data (99 + 1) beginning at the address specified by the next two bytes. The controller stores 0x63 in the EEPROM and increments the EEPROM address pointer. The default value of these two registers is 0x0780. Note that Register 0x0E2C and Register 0x0E2C are the most significant and least significant bytes of the target address, respectively. Because the previous register contains a data instruction, these two registers define a starting address (in this case, 0x0780). The controller stores 0x0780 in the EEPROM and increments the EEPROM pointer by 2. It then transfers 100 bytes from the register map (beginning at Address 0x0780) to the EEPROM and increments the EEPROM address pointer by 101 (100 data bytes and one checksum byte). The 99 bytes transferred correspond to the Profile 6 and Profile 7 parameters in the register map. The default value of this register is 0x80, which the controller interprets as an I/O update instruction. The controller stores 0x80 in the EEPROM and increments the EEPROM address pointer. Table 153. EEPROM Storage Sequence for Operational Control Settings Address 0x0E2F Bits [7:0] Bit Name Operational controls 0x0E30 0x0E31 [7:0] [7:0] Operational controls 0x0E32 [7:0] I/O update Description The default value of this register is 0x10, which the controller interprets as a data instruction. Its decimal value is 16, which tells the controller to transfer 17 bytes of data (16 + 1) beginning at the address specified by the next two bytes. The controller stores 0x10 in the EEPROM and increments the EEPROM address pointer. The default value of these two registers is 0x0A00. Note that Register 0x0E30 and Register 0x0E31 are the most significant and least significant bytes of the target address, respectively. Because the previous register contains a data instruction, these two registers define a starting address (in this case, 0x0A00). The controller stores 0x0A00 in the EEPROM and increments the EEPROM pointer by 2. It then transfers 17 bytes from the register map (beginning at Address 0x0A00) to the EEPROM and increments the EEPROM address pointer by 18 (17 data bytes and one checksum byte). The 17 bytes transferred correspond to the operational controls parameters in the register map. The default value of this register is 0x80, which the controller interprets as an I/O update instruction. The controller stores 0x80 in the EEPROM and increments the EEPROM address pointer. Rev. G | Page 104 of 111 Data Sheet AD9548 Table 154. EEPROM Storage Sequence for End of Data Address 0x0E33 0x0E34 to 0x0E3F Bits [7:0] Bit Name End of data Continuation of user scratch pad area Description The default value of this register is 0xFF, which the controller interprets as an end instruction. The controller stores this instruction in the EEPROM, resets the EEPROM address pointer, and enters an idle state. This area is unused in the default configuration and is available for additional EEPROM storage sequence commands. Note that the EEPROM storage sequence must always end with either an end of data or pause command. Rev. G | Page 105 of 111 AD9548 Data Sheet POWER SUPPLY PARTITIONS The AD9548 features multiple power supplies, and their power consumption varies with the AD9548 configuration. This section provides information about which power supplies can be grouped together and how the power consumption of each block varies with frequency. The numbers quoted here are for comparison only. Please refer to the Specifications section for exact numbers. With each group, bypass capacitors of 1 μF in parallel with 10 μF should be used. Upon applying power to the device, internal circuitry monitors the 1.8 V digital core supply and the 3.3 V digital input/output supply. When these supplies cross the desired threshold level, the device generates an internal 10 μs reset pulse. This pulse does not appear on the RESET pin. 3.3 V SUPPLIES The 3.3 V supply domain consists of two main partitions, digital (DVDD3) and analog (AVDD3). Take care to keep these two supply domains separate. Furthermore, the AVDD3 consists of two subdomains: the clock distribution output domain (Pin 31, Pin 37, Pin 38, and Pin 44) and the rest of the AVDD3 supply connections. Generally, these supply domains can be joined together. However, if an application requires 1.8 V CMOS driver operation in the clock distribution output block, then provide one 1.8 V supply domain to power the clock distribution output block. Each output driver has a dedicated supply pin, as shown in Table 155. Table 155. Output Driver Supply Pins Output Driver OUT0 OUT1 OUT2 OUT3 Supply Pin 31 37 38 44 1.8 V SUPPLIES The 1.8 V supply domain consists of two main partitions, digital (DVDD) and analog (AVDD). These two supply domains must be kept separate. Rev. G | Page 106 of 111 Data Sheet AD9548 THERMAL PERFORMANCE Table 156. Thermal Parameters for the AD9548 88-Lead LFCSP Package Symbol θJA θJMA θJMA θJB θJC ΨJT 1 2 Thermal Characteristic Using a JEDEC51-7 Plus JEDEC51-5 2S2P Test Board1 Junction-to-ambient thermal resistance, 0.0 m/s airflow per JEDEC JESD51-2 (still air) Junction-to-ambient thermal resistance, 1.0 m/s airflow per JEDEC JESD51-6 (moving air) Junction-to-ambient thermal resistance, 2.5 m/s airflow per JEDEC JESD51-6 (moving air) Junction-to-board thermal resistance, 1.0 m/sec airflow per JEDEC JESD51-8 (moving air) Junction-to-case thermal resistance (die-to-heat sink) per MIL-Std 883, Method 1012.1 Junction-to-top-of-package characterization parameter, 0 m/sec airflow per JEDEC JESD51-2 (still air) Value2 18 16 14 9 1.0 0.1 Unit °C/W °C/W °C/W °C/W °C/W °C/W The exposed pad on the bottom of the package must be soldered to ground to achieve the specified thermal performance. Results are from simulations. The PCB is a JEDEC multilayer type. Thermal performance for actual applications requires careful inspection of the conditions in the application to determine if they are similar to those assumed in these calculations. The AD9548 is specified for a case temperature (TCASE). To ensure that TCASE is not exceeded, an airflow source can be used. Use the following equation to determine the junction temperature on the application PCB: TJ = TCASE + (ΨJT × PD) Values of θJA are provided for package comparison and PCB design considerations. θJA can be used for a first order approximation of TJ by the equation TJ = TA + (θJA × PD) where TA is the ambient temperature (°C). where: TJ is the junction temperature (°C). TCASE is the case temperature (°C) measured by the customer at the top center of the package. ΨJT is the value as indicated in Table 156. PD is the power dissipation (see the Power Dissipation section). Values of θJC are provided for package comparison and PCB design considerations when an external heat sink is required. Values of θJB are provided for package comparison and PCB design considerations. Rev. G | Page 107 of 111 AD9548 Data Sheet CALCULATING DIGITAL FILTER COEFFICIENTS The digital loop filter coefficients (, , , and (see Figure 42)) relate to the time constants (T1, T2, and T3) associated with the equivalent analog circuit for a third order loop filter (see Figure 69). Note that AD9548 evaluation software contains a profile designer that will compute these coefficients for you. The user should not normally need to use these formulas. FROM CHARGE PUMP TO VCO R2 R3 C1 With an expression for T1 and T3, it is possible to define an adjusted open-loop bandwidth (fC) that is slightly less than fP. It can be shown that ωC (fC expressed as a radian frequency) is expressible in terms of T1, T3, and θ (phase margin) as C 08022-042 C2 T2 Figure 69. Third Order Analog Loop Filter The design process begins by deciding on two design parameters related to the second order loop filter shown in Figure 70—the desired open-loop bandwidth (fP) and phase margin (. K R2 08022-043 Figure 70. Second Order Analog Loop Filter An analysis of the second order loop filter leads to its primary time constant, T1. It can be shown that T1 is expressible in terms of fP and as 1 sin( ) P cos( ) An analysis of the third order loop filter leads to the definition of another time constant, T3. It can be shown that T3 is expressible in terms of the desired amount of additional attenuation introduced by R3 and C3 at some specified frequency offset (fOFFSET) from the PLL output frequency. T3 ATTEN 10 OFFSET 1 5 fP U 1 V C 2 T2 D 1 T 1 T T1 K 32 1 1 f S T1 T2 32 f S T1 32 f S T3 2 C 2 1 1 C T2 C 3 2 The if() function y = if(test_statement, true_value, false_value) Note that ATTEN is the desired excess attenuation in decibels. Furthermore, ATTEN and ωOFFSET should be chosen so that fS Calculation of the coefficient register values requires the application of some special functions described as follows: 1 where OFFSET 2f OFFSET . T3 2 33 where S, U, and V are the integer and fractional feedback divider values that reside in the profile registers. Keep in mind that the desired integer feedback divide ratio is one more than the stored value of S (hence, the +1 term in the equation for D in this equation). This leads to the digital filter coefficients given by where P 2f P . 10 30,517,578,125 DS C2 T1 1 C T1 T3 2 Calculation of the digital loop filter coefficients requires a scaling constant, K (related to the system clock frequency, fS), and the PLL feedback divide ratio, D. TO VCO C1 2 T T T1 T3 1 1 3 1 T1 T3 tan( )2 It can also be shown that the adjusted open-loop bandwidth leads to T2 (the secondary time constant of the second order loop filter) expressed as C3 FROM CHARGE PUMP T1 T3 tan( ) 2 T1T3 T1 T3 where test_statement is a conditional expression (for example, x < 3), true_value is what y equals if the conditional expression is true, and false_value is what y equals if the conditional expression is false. The round() function y = round(x) Rev. G | Page 108 of 111 Data Sheet AD9548 If x is an integer, then y = x. Otherwise, y is the nearest integer to x. For example, round(2.1) = 2, round(2.5) = 3, and round(−3.1) = −3. binary decimal point of α0 to the left to accommodate small values of α. Calculation of α1 is a two-step process, as follows: The ceil() function w = if (α < 1, − ceil(log 2 (α )), 0) α 1 = if (α < 1, min[63, max(0, w)], 0) y = ceil(x) If x is an integer, then y = x. Otherwise, y is the next integer to the right on the number line. For example, ceil(2.8) = 3, whereas ceil(−2.8) = −2. The min() function If gain is necessary (that is, α > 1), then it is beneficial to apply most or all of it to the front-end gain (α2) implying that the calculation of α2 is to be done before α3. Calculation of α2 is a three-step process that leads directly to the calculation of α3. y = min(x0, x1, ... xn) x = if (α > 1, ceil(log 2 (α )), 0) where x0 through xn is a list of real numbers, and the value of y is the number in the list that is the farthest to the left on the number line. α 2 = if ( y ≥ 8, 7, y ) The max() function α 3 = if ( y ≥ 8, y − 7, 0) Calculation of α0 is a two-step process, as follows: y = max(x0, x1, ... xn) where x0 through xn is a list of real numbers, and the value of y is the number in the list that is the farthest to the right on the number line. The log2() function log 2 ( x) = y = if (α > 1, min[22, max(0, x)], 0) z = round(α × 216+α 1 −α 2 −α 3 ) α 0 = min[65,535 , max(1, z )] Using the example value of α = 0.012735446 yields w = 6, so α1 = 6 ln ( x) ln (2) x = 0 and y = 0, so α2 = 0 and α3 = 0 z = 53,416.332099584, so α0 = 53,416 where ln() is the natural log function and x is a positive, nonzero number. Assume that the coefficient calculations for α, β, γ, and δ yield the following results: α = 0.012735446 This leads to the following quantized value, which is very close to the desired value of 0.012735446: α quantized = 53416 × 2 −22 ≈ 0.01273566821 CALCULATION OF THE β REGISTER VALUES β = −6.98672 × 10 −5 The quantized β coefficient consists of two components, β0 and β1 according to γ = −7.50373 × 10 −5 δ = 0.002015399 − β ≈ β quantized = β 0 × 2 − (17 + β1 ) These values are floating point numbers that must be quantized according to the bit widths of the linear and exponential components of the coefficients as they appear in the register map. Note that the calculations that follow indicate a positive value for the register entries of β and γ. The reason is that β and γ, which are supposed to be negative values, are stored in the AD9548 registers as positive values. The AD9548 converts the stored values to negative numbers within its signal processing core. A detailed description of the register value computations for α, β, γ, and δ is contained in the Calculation of the α Register Values section to the Calculation of the δ Register Values section. CALCULATION OF THE α REGISTER VALUES The quantized α coefficient consists of four components, α0, α1, α2, and α3 according to α ≈ α quantized = α 0 × 2 −16−α1 +α 2 +α3 where β0 and β1 are the register values. Calculation of β1 is a two-step process that leads to the calculation of β0, which is also a two-step process. x = −ceil(log 2 ( β )) β 1 = min[31, max(0, x)] y = round( β × 217 + β1 ) β 0 = min[131,071 , max(1, y )] Using the example value of −β = 6.98672 × 10−5 yields x = 13, so β1 = 13 y = 75,019.3347657728, so β0 = 75,019 This leads to the following quantized value, which is very close to the desired value of 6.98672x10−5: where α0, α1, α2, and α3 are the register values. α2 provides front-end gain, α3 provides back-end gain, and α1 shifts the Rev. G | Page 109 of 111 β quantized = 75,019 × 2 −30 ≈ 6.986688823 × 10 −5 AD9548 Data Sheet CALCULATION OF THE γ REGISTER VALUES CALCULATION OF THE δ REGISTER VALUES The quantized γ coefficient consists of two components, γ0 and γ1 according to The quantized δ coefficient consists of two components, δ0 and δ1, according to δ ≈ δ quantized = δ 0 × 2 − (15 + δ − γ ≈ γ quantized = γ 0 × 2 − (17 + γ 1 ) where γ0 and γ1 are the register values. Calculation of γ1 is a twostep process that leads to the calculation of γ0, which is also a two-step process. x = −ceil(log 2 ( γ )) y = round( γ × 2 ) y = round(δ × 215 + δ 1 ) δ 0 = min[32,767 , max(1, y )] Using the example value of −γ = 7.50373 × 10 yields −5 Given the example value of δ = 0.002015399, the preceding formulas yield x = 13, so γ1 = 13 x = 8, δ1 = 8 y = 80,570.6873700352, so γ1 = 80,571 This leads to the following quantized value, which is very close to the desired value of 7.50373x10−5: γ quantized = 80571 × 2 Calculation of δ1 is a two-step process that leads to the calculation of δ0, which is also a two-step process. δ 1 = min[31, max(0, x)] γ 0 = min[131,071 , max(1, y )] −30 where δ0 and δ1 are the register values. x = −ceil(log 2 (δ )) γ 1 = min[31, max(0, x)] 17 + γ 1 ≈ 7.503759116 × 10 1) −5 y = 16,906.392174592, δ0 = 16,906 This leads to the following quantized value, which is very close to the desired value of 0.002015399: δ quantized = 16906 × 2 −23 ≈ 0.002015352249 Rev. G | Page 110 of 111 Data Sheet AD9548 OUTLINE DIMENSIONS 12.10 12.00 SQ 11.90 0.60 MAX 0.30 0.23 0.18 0.60 MAX 88 67 66 1 PIN 1 INDICATOR PIN 1 INDICATOR 11.85 11.75 SQ 11.65 0.50 BSC 0.50 0.40 0.30 23 22 10.50 REF 0.70 0.65 0.60 0.05 MAX 0.01 NOM COPLANARITY 0.08 0.20 REF SEATING PLANE FOR PROPER CONNECTION OF THE EXPOSED PAD, REFER TO THE PIN CONFIGURATION AND FUNCTION DESCRIPTIONS SECTION OF THIS DATA SHEET. *COMPLIANT TO JEDEC STANDARDS MO-220-VRRD EXCEPT FOR MINIMUM THICKNESS AND LEAD COUNT. 07-02-2012-B 12° MAX 45 44 BOTTOM VIEW TOP VIEW *0.90 0.85 0.75 6.15 6.00 SQ 5.85 EXPOSED PAD Figure 71. 88-Lead Lead Frame Chip Scale Package [LFCSP_VQ] 12 mm × 12 mm Body, Very Thin Quad (CP-88-2) Dimensions shown in millimeters ORDERING GUIDE Model1 AD9548BCPZ AD9548BCPZ-REEL7 AD9548/PCBZ 1 Temperature Range −40°C to +85°C −40°C to +85°C −40°C to +85°C Package Description 88-Lead Lead Frame Chip Scale Package [LFCSP_VQ] 88-Lead Lead Frame Chip Scale Package [LFCSP_VQ] Evaluation Board Z = RoHS Compliant Part. ©2009–2014 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. D08022-0-12/14(G) Rev. G | Page 111 of 111 Package Option CP-88-2 CP-88-2 CP-88-2