KBL400 10

KBL400_10
PRV : 50 - 1000 Volts
Io : 4.0 Amperes
Features
• High case dielectric strength
• High surge current capability
• High reliability
• Low reverse current
• Low forward voltage drop
• Ideal for printed circuit board
• RoHS compliant package
Mechanical Data
• Case : Molded plastic, KBL pacakge
• Epoxy : UL94V-O rate flame retardant
• Terminals : Plated lead solderable per MIL-STD-202,
Method 208 guaranteed
• Polarity : Polarity symbols marked on case
• Mounting position : Any
• Weight : 5.15 grams
Graphic symbol
Packing & Order Information
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25 °C ambient temperature unless otherwise specifie.
Single phase, half wave, 60 Hz, resistive or inductive load
For capacitive load, derate current by 20%
Symbol
KBL
400
KBL
401
KBL
402
KBL
404
KBL
406
KBL
408
KBL
410
Unit
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
V
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
V
Maximum DC Blocking Voltage
VDC
50
100
200
400
600
800
1000
V
Rating
Publication Order Number: [KBL400_10]
© Bruckewell Technology Corporation Rev. A -2014
KBL400_10
PRV : 50 - 1000 Volts
Io : 4.0 Amperes
Rating at 25 °C ambient temperature unless otherwise specifie.
Single phase, half wave, 60 Hz, resistive or inductive load
For capacitive load, derate current by 20%
Maximum Average Forward Current
Tc = 50°C
Rating for fusing ( t < 8.3 ms. )
Typical Thermal Resistance (Note 2)
IF(AV)
4.0
A
It
2
166
AS
RθJA
10
°C/W
2
Rating at 25 °C ambient temperature unless otherwise specifie.
Single phase, half wave, 60 Hz, resistive or inductive load
For capacitive load, derate current by 20%
Rating
Symbol
KBL
400
KBL
401
KBL
402
KBL
404
KBL
406
KBL
408
KBL
410
Unit
Peak Forward Surge Current,
Single half sine wave
IFSM
200
V
VF
1.1
V
Maximum DC Reverse Current Ta = 25°C
IR
10
V
at Rated DC Blocking Voltage Ta = 100°C
IR(H)
1.0
A
TJ
-55 to +150
°C
TSTG
-55 to +150
°C
Superimposed on rated load
(JEDEC Method)
Maximum Forward Voltage per Diode
at F = 1.0 A
Operating junction temperature range
Storage temperature range
Notes
(1) Thermal resistance from Junction to Ambient with units mounted on a 3" X 3" X 0.11" THK ( 7.5cm X
7.5cm X 0.3cm ) Cu. plate.
Publication Order Number: [KBL400_10]
© Bruckewell Technology Corporation Rev. A -2014
KBL400_10
PRV : 50 - 1000 Volts
Io : 4.0 Amperes
■RATING AND CHARACTERISTIC CURVES ( KBL400 - KBL410 )
FIG.1 - DERATING CURVE FOR OUTPUT
RECTIFIED CURRENT
FIG.2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
FIG.3 - TYPICAL FORWARD CHARACTERISTICS
FIG.4 - TYPICAL REVERSE CHARACTERISTICS
PER DIODE
Publication Order Number: [KBL400_10]
© Bruckewell Technology Corporation Rev. A -2014
KBL400_10
PRV : 50 - 1000 Volts
Io : 4.0 Amperes
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE
WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Bruckewell Technology Inc., its affiliates, agents, and employees, and all persons acting on its or
their behalf (collectively, “Bruckewell”), disclaim any and all liability for any errors, inaccuracies or
incompleteness contained in any datasheet or in any other disclosure relating to any product.
Bruckewell makes no warranty, representation or guarantee regarding the suitability of the products
for any particular purpose or the continuing production of any product. To the maximum extent
permitted by applicable law, Bruckewell disclaims
(i) Any and all liability arising out of the application or use of any product.
(ii) Any and all liability, including without limitation special, consequential or incidental damages.
(iii) Any and all implied warranties, including warranties of fitness for particular purpose,
non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on
Bruckewell’s knowledge of typical requirements that are often placed on Bruckewell products in
generic applications.
Such statements are not binding statements about the suitability of products for a particular
application. It is the customer’s responsibility to validate that a particular product with the properties
described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance
may vary over time.
Product specifications do not expand or otherwise modify Bruckewell’s terms and conditions of
purchase, including but not limited to the warranty expressed therein.
Publication Order Number: [KBL400_10]