NetXtend Flex Power Battery Enclosure Data Sheet

NetXtend™ Flex Power & Battery Enclosure
Key Features
NetSure™ 502 DC Power System
neSure™ rectifiers provide high
energy efficiency
nRemotely view and control
system via Ethernet
nAdvanced remote monitoring
with ACU+ controller
NetXtend™ Flex Enclosure
nSeparate temperaturecontrolled zones for power
and batteries
nDoor-mounted cooling
system & rear cable-entry
compartment
nPull out battery drawers
accept VRLA batteries
nTelcordia GR-487 certified,
Seismic Zone-4 rated
and UL Listed
Delivering industry-leading NetSure™ DC power
reliability and multi-string high capacity battery backup,
the NetXtend™ Flex Power & Battery Enclosure fully
supports networking equipment at wireless cell sites.
Description
The NetXtend™ Flex Power & Battery Enclosure is designed to house DC power equipment,
electronics and VRLA batteries in a single cabinet. Two temperature controlled compartments
are monitored with an Environmental Control Unit (ECU) that adjusts thermal settings to
maintain ideal conditions within each chamber, while simultaneously decreasing system power
consumption and noise. All DC power-feed cables to customer equipment are surge protected
at the distribution bus. Cabinets are available in both 60" and 72" heights.
Application
The NetXtend™ Flex Power & Battery Enclosure is a full featured outdoor equipment cabinet
designed for use at wireless cell sites. The enclosure can be configured with several different
NetSure™ DC power systems, depending on your power needs, and includes a separate
compartment for large-capacity VRLA batteries.
Technical Specifications
DC Power System Features
Nominal System Voltage -48 VDC
Control
Microprocessor (ACU+)
Rated Output Capacity – Maximum Configuration
NetSure™ 502 System
ZZ041: 150 A (N+1)
(582136800)
ZZ054: 350 A (N+1)
Rectifier
41.7 A (2000 W) output
Distribution Panel
(20) load positions available,
for ZZ041
(4) GMT fuse positions available
for ZZ054
Top: (24) load positions available;
Bottom: (3) battery disconnect positions available,
(11) load positions available,
(4) GMT fuse positions available
Environmental
Operating Temperature
Humidity
-40 °F to 115 °F (-40 °C to 46 °C) continuous
0% to 95% relative humidity, non-condensing
Thermal Solutions
Power Chamber
Battery Chamber
2500 watt door-mounted heat exchanger
Thermoelectric Cooling/Heating (VRLA Batteries)
Equipment
Rack Space
Ground Bar
Terminal Block
Safety
DC power system
Enclosure
160300D-NXFlexPwrBat / 0614
See ordering information
10 positions
12-position Phoenix alarm block, 32-position
Phoenix alarm bunching block
UL 1801 Listed (US & Canada), NEBS Level 3
GR-487, UL 60950, and Seismic Zone 4 compliant
1
NetXtend™ Flex Power & Battery Enclosure
Ordering Information
Part Number
F2013066
equipped with:
F2013084
equipped with:
Description
Outdoor DC Power System, 752 lbs.
F1010697 NetXtend™ Flex Enclosure
H x W x D: 183 cm x 81 cm x 99 cm (72" x 32" x 39")
15 RU total equipment space; 3 RU available
(1) 582136800ZZ054 NetSure™ 502 DC power system
(1) 58213680013 two power shelves, 58 cm (23") w/dist.
(1) 1M820BNAZZ006 ACU+ controller
(1) 582136800MC NetSure™ 502 (2) row distribution cab.
(2) 58213680090 temperature probes, 3 m (9.8 ')
(6) 540946 4.2 m (14') Molex AC input cord
(1) 541308 relay output cable, 24 position, shelf
(1) 541309 relay output assembly cable, 24 position, cust
(1) 423349400 ESD ground assembly
(1) AC junction box*
549017 GMT fuse option board, (4) positions available
(3) pull-out battery trays; thermoelectric cooling (VRLA batteries)
2500 watt door-mounted heat exchanger
12-pair Phoenix alarm block
32-pair Phoenix alarm bunching block
Strikesorb DC surge protection
(3) 100 amp DC battery disconnects
Duplex AC convenience outlet
10-position ground bar
Outdoor DC Power System, 737 lbs.
F1010698 NetXtend™ Flex Enclosure
H x W x D: 183 cm x 81 cm x 99 cm (72" x 32" x 39")
15 RU total equipment space; 9 RU available
(1) 582136800ZZ041 NetSure™ 502 DC power system
(1) 58213680013 two power shelves, 58 cm (23") w/dist.
(1) 1M820BNAZZ006 ACU+ controller
(1) 582136800MC NetSure™ 502 (2) row distribution cab.
(2) 58213680090 temperature probes, 3 m (9.8 ')
(6) 540946 4.2 m (14') Molex AC input cord
(1) 541308 relay output cable, 24 position, shelf
(1) 541309 relay output assembly cable, 24 position, cust
(1) 423349400 ESD ground assembly
(1) AC junction box*
549017 GMT fuse option board, (4) positions available
(3) pull-out battery trays; thermoelectric cooling (VRLA batteries)
2500 watt door-mounted heat exchanger
12-pair Phoenix alarm block
32-pair Phoenix alarm bunching block
Strikesorb DC surge protection
(3) 100 amp DC battery disconnects
Duplex AC convenience outlet
10-position ground bar
* Phoenix pass-through terminal blocks accept individual customer fuse-protected
AC feeds for cabinet circuits.
Part Number
F2013088
equipped with:
Description
Outdoor DC Power System
F1010699 NetXtend™ Flex Enclosure
H x W x D: 152 cm x 81 cm x 99 cm (60" x 32" x 39")
15 RU total equipment space; 9 RU available
(1) 582136800ZZ041 NetSure™ 502 DC power system
(1) 58213680012 power shelf, 58 cm (23") w/distribution
(1) 1
M820BNAZZ005 ACU+ controller
w/ 552363 Verizon software
(1) 582136800AC 58 cm (23") 24 position dist. panel
(2) 58213680090 temperature probes, 3 m (9.8 ')
(1) 423349400 ESD ground assembly
(1) AC junction box*
545333 GMT fuse option board, (4) positions available
(2) pull-out battery trays; thermoelectric cooling (VRLA batteries)
2500 watt door-mounted heat exchanger
12-pair Phoenix alarm block
32-pair Phoenix alarm bunching block
Strikesorb DC surge protection
(2) 100 amp DC battery disconnects
Duplex AC convenience outlet
10-position ground bar
* Phoenix pass-through terminal blocks accept individual customer fuse-protected
AC feeds for cabinet circuits.
Accessories
Part Number
Description
Enclosure Accessories
F1010599
10 cm (4") mounting plinth
DC Power Accessories & Spare Parts
1R482000E
Rectifier, NetSure™ 502, -48 VDC, 40 A/2000 W
547490
SM-TEMP, 8-input temperature module
552992
Temperature probe, 10.3 m (33.7')
556155
Temperature probe, 3.3 meters (10.8')
04119122
Temperature probe extension, 10 m (32.8')
552822
Temperature probe sensor, 0.3 m (.98')
1M820BNAZZ005 ACU+ controller for 582136800ZZ041
1M820BNAZZ006 ACU+ controller for 582136800ZZ054
545412
Hardware kit, single position
545405
90 degree adapter, single pole
MA4C5U31
IB2, customer interface board
Bullet nose type circuit breakers (1 A to 250 A)
Supported Batteries
Valve-Regulated Lead-Acid (VRLA) batteries in 170 Ahr – 190 Ahr
N/A
capacities (consult Emerson Engineering for specific models)
Note: Batteries are not supplied by Emerson.
EmersonNetworkPower.com/EnergySystems (North America)
EmersonNetworkPower.eu/EnergySystems (EMEA)
© Emerson Network Power, Energy Systems, North America, Inc. 2014.
Business-Critical Continuity™, Emerson Network Power™, the Emerson Network Power logo, Emerson™ and Consider it Solved are service marks and
trademarks of Emerson Electric Co. EnergyMaster ™, eSure™, NetPerform™, NetReach™, NetSpan™, NetSure™ and NetXtend™ are trademarks of Emerson
Network Power, Energy Systems, North America, Inc. Any other product, brand, or company names or logos are the property of the respective owner.
2
While every precaution has been taken to ensure accuracy and
completeness herein, Emerson Electric Co. assumes no responsibility,
and disclaims all liability, for damages resulting from use of this
information or for any errors or omissions. Specifications subject to
change without notice.
160300D-NXFlexPwrBat / 0614