PCN 1012: IGLOO PLUS Datasheet Update

July 20, 2010
PCN Number: 1012
PCN Change Level: Major
Subject: IGLOO PLUS Datasheet Update
Dear Customer,
This notice is to inform you that IGLOO® PLUS datasheet Revision 11 has been
published. The updated datasheet can be downloaded from the Actel website:
http://www.actel.com/documents/IGLOOPLUS_DS.pdf.
The following key changes have been made to this datasheet:
Change # 1: The versioning system for datasheets has been changed.
Datasheets are assigned a revision number that increments each time the datasheet is
revised.
Change # 2: Table 2-8 • Power Supply State per Mode is new.
Table 2-8 •
Power Supply State per Mode
Modes/Power Supplies
Power Supply Configurations
VCC
VCCPLL
VCCI
VJTAG
VPUMP
Flash*Freeze
On
On
On
On
On/off/floating
Sleep
Off
Off
On
Off
Off
Shutdown
Off
Off
Off
Off
Off
No Flash*Freeze
On
On
On
On
On/off/floating
Note:
Off: Power Supply level = 0 V
Actel Corporation
2061 Stierlin Court, Mountain View, CA 94043
Phone: 650.318.4200 Fax 650.318.4600
Part No. 54400088-0
Change # 3: VIH maximum values in tables were updated as needed to 3.6 V.
Table 2-21 • Summary of Maximum and Minimum DC Input and Output Levels Applicable to Commercial
and Industrial Conditions—Software Default Settings
VIL
Equiv.
Software
Drive Default Slew
Max.
Strength Drive Rate Min.
V
V
Strength
Option2
I/O Standard
VIH
VOL
VOH
IOL1 IOH1
mA mA
Min.
V
Max.
V
Max.
V
Min.
V
2.4
3.3 V LVTTL /
3.3 V LVCMOS
12 mA
12 mA
High –0.3
0.8
2
3.6
0.4
3.3 V LVCMOS
Wide Range3
100 µA
12 mA
High –0.3
0.8
2
3.6
0.2
2.5 V LVCMOS
12 mA
12 mA
High –0.3
0.7
1.7
3.6
0.7
1.7
12
12
1.8 V LVCMOS
8 mA
8 mA
High –0.3 0.35 * VCCI 0.65 * VCCI 3.6
0.45
VCCI – 0.45
8
8
12
12
VDD 3 0.2 0.1
0.1
4 mA
4 mA
High –0.3 0.35 * VCCI 0.65 * VCCI 3.6
0.25 * VCCI 0.75 * VCCI
4
4
1.2 V LVCMOS
2 mA
2 mA
High –0.3 0.35 * VCCI 0.65 * VCCI 3.6
0.25 * VCCI 0.75 * VCCI
2
2
1.2 V LVCMOS
Wide Range4,5
100 µA
2 mA
High –0.3 0.3 * VCCI 0.7 * VCCI
1.5 V LVCMOS
4
3.6
0.1
VCCI – 0.1 0.1
0.1
Notes:
1.
2.
Currents are measured at 85°C junction temperature.
Note that 1.2 V LVCMOS and 3.3 V LVCMOS wide range are applicable to 100 µA drive strength only. The configuration will
not operate at the equivalent software default drive strength. These values are for normal ranges only.
3.
All LVCMOS 3.3 V software macros support LVCMOS 3.3 V wide range as specified in the JESD-8B specification.
4.
Applicable to IGLOO PLUS V2 devices operating at VCCI ≥ VCC.
5.
All LVCMOS 1.2 V software macros support LVCMOS 1.2 V wide range as specified in the JESD8-12 specification.
Actel Corporation
2061 Stierlin Court, Mountain View, CA 94043
Phone: 650.318.4200 Fax 650.318.4600
2
Change # 4: Table 2-29 • I/O Weak Pull-Up/Pull-Down Resistances was revised,
including addition of 3.3 V and 1.2 V LVCMOS wide range. The notes defining
RWEAK PULLUP-MAX and RWEAK PULLDOWN-MAX were revised.
Table 2-29 • I/O Weak Pull-Up/Pull-Down Resistances
Minimum and Maximum Weak Pull-Up/Pull-Down Resistance Values
R(WEAK PULL-UP)1
(Ω)
Min.
Max.
R(WEAK PULL-DOWN)2
(Ω)
Min.
Max.
3.3 V
10 K
45 K
10 K
45 K
3.3 V (wide range I/Os)
10 K
45 K
10 K
45 K
2.5 V
11 K
55 K
12 K
74 K
1.8 V
18 K
70 K
17 K
110 K
1.5 V
19 K
90 K
19 K
140 K
1.2 V
25 K
110 K
25 K
150 K
1.2 V (wide range I/Os)
19 K
110 K
19 K
150 K
VCCI
Notes:
1.
2.
R(WEAK PULL-UP-MAX) = (VCCImax – VOHspec) / I(WEAK PULL-UP-MIN)
R(WEAK PULLDOWN-MAX) = (VOLspec) / I(WEAK PULLDOWN-MIN)
Change # 5: Table 2-31 • Duration of Short Circuit Event before Failure was revised to
change the maximum temperature from 110°C to 100°C, with an example of six
months instead of three months.
Table 2-31 • Duration of Short Circuit Event before Failure
Temperature
Time before Failure
–40°C
> 20 years
0°C
> 20 years
25°C
> 20 years
70°C
5 years
85°C
2 years
100°C
6 months
Actel Corporation
2061 Stierlin Court, Mountain View, CA 94043
Phone: 650.318.4200 Fax 650.318.4600
3
Change # 6: Table 2-90 • IGLOO PLUS CCC/PLL Specification (1.5 V) and Table 2-91
• IGLOO PLUS CCC/PLL Specification (1.2 V) were revised.
VCO output jitter and maximum peak-to-peak jitter data were changed. Three notes were
added to the table in connection with these changes.
Table 2-90 • IGLOO PLUS CCC/PLL Specification
For IGLOO PLUS V2 or V5 devices, 1.5 V DC Core Supply Voltage
Parameter
Min.
Clock Conditioning Circuitry Input Frequency fIN_CCC
Clock Conditioning Circuitry Output Frequency fOUT_CCC
Delay Increments in Programmable Delay Blocks
Max.
Units
1.5
250
MHz
0.75
250
MHz
1, 2
Typ.
360
Number of Programmable Values in Each Programmable
Delay Block
ps
32
Serial Clock (SCLK) for Dynamic PLL3,4
Input Cycle-to-Cycle Jitter (peak
magnitude)
100
Acquisition Time
Tracking Jitter5
MHz
LockControl = 0
300
µs
LockControl = 1
6.0
ms
LockControl = 0
2.5
LockControl = 1
1.5
ns
48.5
51.5
%
Delay Range in Block: Programmable Delay 1
1, 2
1.25
15.65
ns
Delay Range in Block: Programmable Delay 2
1, 2
0.469
15.65
ns
Output Duty Cycle
Delay Range in Block: Fixed Delay
1, 2
VCO Output Peak-to-Peak Period Jitter FCCC_OUT6
3.5
ns
Maximum Peak-to-Peak Period Jitter6,7,8
SSO ≤ 2
SSO ≤ 4 SSO ≤ 8 SSO ≤ 16
0.75 MHz to 50 MHz
0.50%
0.60%
0.80%
1.20%
50 MHz to 250 MHz
2.50%
4.00%
6.00%
12.00%
Actel Corporation
2061 Stierlin Court, Mountain View, CA 94043
Phone: 650.318.4200 Fax 650.318.4600
4
Table 2-91 • IGLOO PLUS CCC/PLL Specification
For IGLOO PLUS V2 Devices, 1.2 V DC Core Supply Voltage
Parameter
Min.
Clock Conditioning Circuitry Input Frequency fIN_CCC
Clock Conditioning Circuitry Output Frequency fOUT_CCC
Delay Increments in Programmable Delay Blocks
Max.
Units
1.5
160
MHz
0.75
160
MHz
1, 2
Typ.
580
Number of Programmable Values in Each Programmable
Delay Block
ps
32
Serial Clock (SCLK) for Dynamic PLL3,4
60
MHz
LockControl = 0
300
µs
LockControl = 1
6.0
ms
LockControl = 0
4
ns
LockControl = 1
3
ns
48.5
51.5
%
2.3
20.86
ns
0.025
20.86
ns
Input Cycle-to-Cycle Jitter (peak magnitude)
Acquisition Time
5
Tracking Jitter
Output Duty Cycle
Delay Range in Block: Programmable Delay 1
Delay Range in Block: Programmable Delay
Delay Range in Block: Fixed Delay
1, 2
2 1, 2
1, 2
VCO Output Peak-to-Peak Period Jitter
5.7
FCCC_OUT6
ns
Maximum Peak-to-Peak Period Jitter6,7,8
SSO ≤ 2 SSO ≤ 4 SSO ≤ 8
SSO ≤ 16
0.75 MHz to 50 MHz
0.50%
1.20%
2.00%
3.00%
50 MHz to 160 MHz
2.50%
5.00%
7.00%
15.00%
Actel Corporation
2061 Stierlin Court, Mountain View, CA 94043
Phone: 650.318.4200 Fax 650.318.4600
5
The following is a list of affected devices.
Table 1 • Affected Devices
AGLP030V2-CS201
AGLP030V2-CS201I
AGLP030V2-CS289
AGLP030V2-CS289I
AGLP030V2-CSG201
AGLP030V2-CSG201I
AGLP030V2-CSG289
AGLP030V2-CSG289I
AGLP030V2-VQ128
AGLP030V2-VQ128I
AGLP030V2-VQG128
AGLP030V2-VQG128I
AGLP030V5-CS201
AGLP030V5-CS201I
AGLP030V5-CS289
AGLP030V5-CS289I
AGLP030V5-CSG201
AGLP030V5-CSG201I
AGLP030V5-CSG289
AGLP030V5-CSG289I
AGLP030V5-VQ128
AGLP030V5-VQ128I
AGLP030V5-VQG128
AGLP030V5-VQG128I
AGLP060V2-CS201
AGLP060V2-CS201I
AGLP060V2-CS289
AGLP060V2-CS289I
AGLP060V2-CSG201
AGLP060V2-CSG201I
AGLP060V2-CSG289
AGLP060V2-CSG289I
AGLP060V2-VQ176
AGLP060V2-VQ176I
AGLP060V2-VQG176
AGLP060V2-VQG176I
AGLP060V5-CS201
AGLP060V5-CS201I
AGLP060V5-CS289
AGLP060V5-CS289I
AGLP060V5-CSG201
AGLP060V5-CSG201I
AGLP060V5-CSG289
AGLP060V5-CSG289I
AGLP060V5-VQ176
AGLP060V5-VQ176I
AGLP060V5-VQG176
AGLP060V5-VQG176I
AGLP125V2-CS281
AGLP125V2-CS281I
AGLP125V2-CS289
AGLP125V2-CS289I
AGLP125V2-CSG281
AGLP125V2-CSG281I
AGLP125V2-CSG289
AGLP125V2-CSG289I
AGLP125V5-CS281
AGLP125V5-CS281I
AGLP125V5-CS289
AGLP125V5-CS289I
AGLP125V5-CSG281
AGLP125V5-CSG281I
AGLP125V5-CSG289
AGLP125V5-CSG289I
Several other minor updates have also been made to the IGLOO PLUS datasheet. Please
refer to the “List of Changes” chapter (page 4-1) for those updates.
For answers to questions, please contact the Actel Technical Support hotline at
[email protected].
Regards,
Actel
Actel Corporation
2061 Stierlin Court, Mountain View, CA 94043
Phone: 650.318.4200 Fax 650.318.4600
6