July 20, 2010 PCN Number: 1012 PCN Change Level: Major Subject: IGLOO PLUS Datasheet Update Dear Customer, This notice is to inform you that IGLOO® PLUS datasheet Revision 11 has been published. The updated datasheet can be downloaded from the Actel website: http://www.actel.com/documents/IGLOOPLUS_DS.pdf. The following key changes have been made to this datasheet: Change # 1: The versioning system for datasheets has been changed. Datasheets are assigned a revision number that increments each time the datasheet is revised. Change # 2: Table 2-8 • Power Supply State per Mode is new. Table 2-8 • Power Supply State per Mode Modes/Power Supplies Power Supply Configurations VCC VCCPLL VCCI VJTAG VPUMP Flash*Freeze On On On On On/off/floating Sleep Off Off On Off Off Shutdown Off Off Off Off Off No Flash*Freeze On On On On On/off/floating Note: Off: Power Supply level = 0 V Actel Corporation 2061 Stierlin Court, Mountain View, CA 94043 Phone: 650.318.4200 Fax 650.318.4600 Part No. 54400088-0 Change # 3: VIH maximum values in tables were updated as needed to 3.6 V. Table 2-21 • Summary of Maximum and Minimum DC Input and Output Levels Applicable to Commercial and Industrial Conditions—Software Default Settings VIL Equiv. Software Drive Default Slew Max. Strength Drive Rate Min. V V Strength Option2 I/O Standard VIH VOL VOH IOL1 IOH1 mA mA Min. V Max. V Max. V Min. V 2.4 3.3 V LVTTL / 3.3 V LVCMOS 12 mA 12 mA High –0.3 0.8 2 3.6 0.4 3.3 V LVCMOS Wide Range3 100 µA 12 mA High –0.3 0.8 2 3.6 0.2 2.5 V LVCMOS 12 mA 12 mA High –0.3 0.7 1.7 3.6 0.7 1.7 12 12 1.8 V LVCMOS 8 mA 8 mA High –0.3 0.35 * VCCI 0.65 * VCCI 3.6 0.45 VCCI – 0.45 8 8 12 12 VDD 3 0.2 0.1 0.1 4 mA 4 mA High –0.3 0.35 * VCCI 0.65 * VCCI 3.6 0.25 * VCCI 0.75 * VCCI 4 4 1.2 V LVCMOS 2 mA 2 mA High –0.3 0.35 * VCCI 0.65 * VCCI 3.6 0.25 * VCCI 0.75 * VCCI 2 2 1.2 V LVCMOS Wide Range4,5 100 µA 2 mA High –0.3 0.3 * VCCI 0.7 * VCCI 1.5 V LVCMOS 4 3.6 0.1 VCCI – 0.1 0.1 0.1 Notes: 1. 2. Currents are measured at 85°C junction temperature. Note that 1.2 V LVCMOS and 3.3 V LVCMOS wide range are applicable to 100 µA drive strength only. The configuration will not operate at the equivalent software default drive strength. These values are for normal ranges only. 3. All LVCMOS 3.3 V software macros support LVCMOS 3.3 V wide range as specified in the JESD-8B specification. 4. Applicable to IGLOO PLUS V2 devices operating at VCCI ≥ VCC. 5. All LVCMOS 1.2 V software macros support LVCMOS 1.2 V wide range as specified in the JESD8-12 specification. Actel Corporation 2061 Stierlin Court, Mountain View, CA 94043 Phone: 650.318.4200 Fax 650.318.4600 2 Change # 4: Table 2-29 • I/O Weak Pull-Up/Pull-Down Resistances was revised, including addition of 3.3 V and 1.2 V LVCMOS wide range. The notes defining RWEAK PULLUP-MAX and RWEAK PULLDOWN-MAX were revised. Table 2-29 • I/O Weak Pull-Up/Pull-Down Resistances Minimum and Maximum Weak Pull-Up/Pull-Down Resistance Values R(WEAK PULL-UP)1 (Ω) Min. Max. R(WEAK PULL-DOWN)2 (Ω) Min. Max. 3.3 V 10 K 45 K 10 K 45 K 3.3 V (wide range I/Os) 10 K 45 K 10 K 45 K 2.5 V 11 K 55 K 12 K 74 K 1.8 V 18 K 70 K 17 K 110 K 1.5 V 19 K 90 K 19 K 140 K 1.2 V 25 K 110 K 25 K 150 K 1.2 V (wide range I/Os) 19 K 110 K 19 K 150 K VCCI Notes: 1. 2. R(WEAK PULL-UP-MAX) = (VCCImax – VOHspec) / I(WEAK PULL-UP-MIN) R(WEAK PULLDOWN-MAX) = (VOLspec) / I(WEAK PULLDOWN-MIN) Change # 5: Table 2-31 • Duration of Short Circuit Event before Failure was revised to change the maximum temperature from 110°C to 100°C, with an example of six months instead of three months. Table 2-31 • Duration of Short Circuit Event before Failure Temperature Time before Failure –40°C > 20 years 0°C > 20 years 25°C > 20 years 70°C 5 years 85°C 2 years 100°C 6 months Actel Corporation 2061 Stierlin Court, Mountain View, CA 94043 Phone: 650.318.4200 Fax 650.318.4600 3 Change # 6: Table 2-90 • IGLOO PLUS CCC/PLL Specification (1.5 V) and Table 2-91 • IGLOO PLUS CCC/PLL Specification (1.2 V) were revised. VCO output jitter and maximum peak-to-peak jitter data were changed. Three notes were added to the table in connection with these changes. Table 2-90 • IGLOO PLUS CCC/PLL Specification For IGLOO PLUS V2 or V5 devices, 1.5 V DC Core Supply Voltage Parameter Min. Clock Conditioning Circuitry Input Frequency fIN_CCC Clock Conditioning Circuitry Output Frequency fOUT_CCC Delay Increments in Programmable Delay Blocks Max. Units 1.5 250 MHz 0.75 250 MHz 1, 2 Typ. 360 Number of Programmable Values in Each Programmable Delay Block ps 32 Serial Clock (SCLK) for Dynamic PLL3,4 Input Cycle-to-Cycle Jitter (peak magnitude) 100 Acquisition Time Tracking Jitter5 MHz LockControl = 0 300 µs LockControl = 1 6.0 ms LockControl = 0 2.5 LockControl = 1 1.5 ns 48.5 51.5 % Delay Range in Block: Programmable Delay 1 1, 2 1.25 15.65 ns Delay Range in Block: Programmable Delay 2 1, 2 0.469 15.65 ns Output Duty Cycle Delay Range in Block: Fixed Delay 1, 2 VCO Output Peak-to-Peak Period Jitter FCCC_OUT6 3.5 ns Maximum Peak-to-Peak Period Jitter6,7,8 SSO ≤ 2 SSO ≤ 4 SSO ≤ 8 SSO ≤ 16 0.75 MHz to 50 MHz 0.50% 0.60% 0.80% 1.20% 50 MHz to 250 MHz 2.50% 4.00% 6.00% 12.00% Actel Corporation 2061 Stierlin Court, Mountain View, CA 94043 Phone: 650.318.4200 Fax 650.318.4600 4 Table 2-91 • IGLOO PLUS CCC/PLL Specification For IGLOO PLUS V2 Devices, 1.2 V DC Core Supply Voltage Parameter Min. Clock Conditioning Circuitry Input Frequency fIN_CCC Clock Conditioning Circuitry Output Frequency fOUT_CCC Delay Increments in Programmable Delay Blocks Max. Units 1.5 160 MHz 0.75 160 MHz 1, 2 Typ. 580 Number of Programmable Values in Each Programmable Delay Block ps 32 Serial Clock (SCLK) for Dynamic PLL3,4 60 MHz LockControl = 0 300 µs LockControl = 1 6.0 ms LockControl = 0 4 ns LockControl = 1 3 ns 48.5 51.5 % 2.3 20.86 ns 0.025 20.86 ns Input Cycle-to-Cycle Jitter (peak magnitude) Acquisition Time 5 Tracking Jitter Output Duty Cycle Delay Range in Block: Programmable Delay 1 Delay Range in Block: Programmable Delay Delay Range in Block: Fixed Delay 1, 2 2 1, 2 1, 2 VCO Output Peak-to-Peak Period Jitter 5.7 FCCC_OUT6 ns Maximum Peak-to-Peak Period Jitter6,7,8 SSO ≤ 2 SSO ≤ 4 SSO ≤ 8 SSO ≤ 16 0.75 MHz to 50 MHz 0.50% 1.20% 2.00% 3.00% 50 MHz to 160 MHz 2.50% 5.00% 7.00% 15.00% Actel Corporation 2061 Stierlin Court, Mountain View, CA 94043 Phone: 650.318.4200 Fax 650.318.4600 5 The following is a list of affected devices. Table 1 • Affected Devices AGLP030V2-CS201 AGLP030V2-CS201I AGLP030V2-CS289 AGLP030V2-CS289I AGLP030V2-CSG201 AGLP030V2-CSG201I AGLP030V2-CSG289 AGLP030V2-CSG289I AGLP030V2-VQ128 AGLP030V2-VQ128I AGLP030V2-VQG128 AGLP030V2-VQG128I AGLP030V5-CS201 AGLP030V5-CS201I AGLP030V5-CS289 AGLP030V5-CS289I AGLP030V5-CSG201 AGLP030V5-CSG201I AGLP030V5-CSG289 AGLP030V5-CSG289I AGLP030V5-VQ128 AGLP030V5-VQ128I AGLP030V5-VQG128 AGLP030V5-VQG128I AGLP060V2-CS201 AGLP060V2-CS201I AGLP060V2-CS289 AGLP060V2-CS289I AGLP060V2-CSG201 AGLP060V2-CSG201I AGLP060V2-CSG289 AGLP060V2-CSG289I AGLP060V2-VQ176 AGLP060V2-VQ176I AGLP060V2-VQG176 AGLP060V2-VQG176I AGLP060V5-CS201 AGLP060V5-CS201I AGLP060V5-CS289 AGLP060V5-CS289I AGLP060V5-CSG201 AGLP060V5-CSG201I AGLP060V5-CSG289 AGLP060V5-CSG289I AGLP060V5-VQ176 AGLP060V5-VQ176I AGLP060V5-VQG176 AGLP060V5-VQG176I AGLP125V2-CS281 AGLP125V2-CS281I AGLP125V2-CS289 AGLP125V2-CS289I AGLP125V2-CSG281 AGLP125V2-CSG281I AGLP125V2-CSG289 AGLP125V2-CSG289I AGLP125V5-CS281 AGLP125V5-CS281I AGLP125V5-CS289 AGLP125V5-CS289I AGLP125V5-CSG281 AGLP125V5-CSG281I AGLP125V5-CSG289 AGLP125V5-CSG289I Several other minor updates have also been made to the IGLOO PLUS datasheet. Please refer to the “List of Changes” chapter (page 4-1) for those updates. For answers to questions, please contact the Actel Technical Support hotline at [email protected]. Regards, Actel Actel Corporation 2061 Stierlin Court, Mountain View, CA 94043 Phone: 650.318.4200 Fax 650.318.4600 6