WRB_YD -30W Series(2.16) 30W, WIDE INPUT, DIP PACKAGE,ISOLATED®ULATED SINGLE OUTPUT DC-DC CONVERTER FEATURES SELECTION GUIDE ◆Wide (2:1) Input Range ◆Short Circuit Protection(automatic recovery) Input Order code ◆1500VDC Isolation ◆Over Voltage protection ◆Internal SMD construction ◆RoHS Compliance ◆Industry Standard Pin Out ◆MTBF>1000Khours MODEL SELECTION ① ② ③ ④ ⑤ ⑥ WRB 24 15 Y D -30W ①Product Series ②Input Voltage ③Output Voltage ④Wide (2:1) Input Range ⑤DIP Package Style ⑥Rated Power Voltage(VDC) Voltage Current Efficiency Capacitance (%.Typ.) (max,UF.) Nominal Range (VDC) (%,Typ). WRB1203YD-30W 12 9-18 3.3 6000 85 19000 WRB1205YD-30W 12 9-18 5 6000 88 10300 WRB1212YD-30W 12 9-18 12 2500 83 3340 WRB1215YD-30W 12 9-18 15 2000 82 1100 WRB1224YD-30W 12 9-18 24 1250 81 900 WRB2403YD-30W 24 18-36 3.3 6000 81 19500 WRB2405YD-30W 24 18-36 5 6000 88 10200 WRB2412YD-30W 24 18-36 12 2500 81 3300 WRB2415YD-30W 24 18-36 15 2000 83 1100 WRB2424YD-30W 24 18-36 24 1250 85 900 WRB4803YD-30W 48 36-75 3.3 6000 83 19500 WRB4805YD-30W 48 36-75 5 6000 81 10200 WRB4812YD-30W 48 36-75 12 2500 81 3300 WRB4815YD-30W 48 36-75 15 2000 84 1100 WRB4824YD-30W* 48 36-75 24 1250 81 900 ◆Operating Temperature: -40℃~﹢85℃ ◆Six sided metal shielding Output *Designing… COMMON SPECIFICATIONS Parameter APPLICATIONS The WRB_YD-30W Series are specially designed for applications where a wide range input voltage power supplies are isolated from the input power supply in a distributed power supply system on a circuitboard. These productsapply to: 1) Where the voltage of the input power supply is wide range (Voltage range≤2:1); 2) Where isolation is necessary between input and output (Isolation voltage≤1500VDC); 3) Where the regulation of the Output voltage and the output ripple noise are demanded. Conditions Min. Typ. Max. Storage humidity 5 95 % Operating temperature -40 85 ℃ -55 105 ℃ 300 ℃ Storage temperature Lead temperature 1.5mm from case for 10 seconds Case material Isolation voltage Steel,nickel coated, copper Tested for1 minute and 1mA max Isolation resistance Isolation Capacitance 100KHz/1V 1500 VDC 1000 MΩ 1000 pF MTBF 1000 K hours Weight 45 g INPUT SPECIFICATIONS Parameter Conditions Min. Typ. Max. Units Start voltage/Under 12V input models 8.6/8.1 8.8/8. 9/8.5 VDC voltage shutdown 24V input models 17.5/16 17.8/1 18/17 VDC 48V input models 34/32 35/33 36/34 VDC Start up time 20 MS Input filter MICRODC reserves the copyright http://www.microdc.cn Units Pi Method of Remote On 3.5-40VDC or open circuit (Reference point:GND) Off 0-1.2VDC Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 11of 3 WRB_YD -30W Series(2.16) TEMPERATURE CHARACTERISTICS Parameter Conditions Output voltage accuracy Refer to recommended circuit Over load protection Input voltage range Output Short Circuit Input voltage range Load regulation From 10% to 100% load Min. 120 TYPICAL CHARACTERISTICS Typ. Max. Units ±1 ±3 % 130 150 % Hiccup,automatics recovery ±0.5 Trim Temperature drift (Vout) Ripple&Noise Tested under 20MHz brand Transient recovery time 25% load change Transient peak deviation 50 ±2 % VDC 0.02 Input voltage from low to high Over voltage protection ±1 ±10%V0 Line regulation Temperature Derating Graph %/℃ ±0.2 ±0.5 % 75 150 mV 200 300 us ±3 ±5 % 3.3V 3.63 4.29 VDC 5V 5.5 6.5 VDC 12V 13.2 15.6 VDC 15V 16.5 19.5 VDC 24V 26.4 31.2 VDC Note: 1. All specifications are measured at TA=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 2. The CTRL control pin voltage is referenced to GND. 3. Typical efficiency value at nominal input voltage and full load. 4. Capacitor MAX load tested at nominal input voltage and constant resistive load. 5. Refer to the diagram of Output Voltage trim up/down for trim applications. 6. The products cannot be used in parallel and in plug and play. Case material &EFFICIENCY CURVE DERATING DERATING& RECOMMENDED CIRCUIT Output Graph In order to abtain better performance for the DC/DC models.it’s recommended that use input and output filters as Fig.1 shown. Requirement on output load In order to ensure the product operate efficiently and reliably,in addition to a max load(namely full load), a minimum load is specified for this kind of DC/DC converter.Make sure the specified range of input voltage is not exceeded,the minimum output load no less than 10% load load.If the actual load is less than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability will reduce greatly.If the actual output power is very small,please add an appropriate resistor as extra loading,or contact our company for other lower output power products. L:12uH C:100uF/100V OUTPUT VOLTAGE TRIM Output Graph Curve of Efficiency VS input Voltage WRB2424YD-30W Curve of Efficiency VS output load WRB2424YD-30W No parallel connection or plug and play http://www.microdc.cn Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 22of 3 WRB_YD -30W Series(2.16) OUTLINE DIMENSIONS & FOOTPRINT DETAILS MECHANICAL DIMENSIONS Note: Unit:mm[inch] Pin diameter:1.00mm[0.039inch] Pin diameter tolerances:±0.05mm[±0.002inch] General tolerances:±0.25mm[±0.010inch] RECOMMENDED FOOTPRINT RECOMMENDED FOOTPRINT Top view grid:2.54mm(0.1inch) diameter:1.50mm(0.059inch) TUBE OUTLINE DIMENSIONS FOOTPRINT DETAILS Pin Single 1 Vin 2 GND 3 Ctrl 4 Trim 5 0V 6 +Vo Note: The CTRL control pin voltage is referenced to GND When the environment temperature is higher than 71 71℃,, the product output power should be less then 60% of the rated power. No parallel connection or plug and play. Use dual output simultaneously,forbid pening output pin (0V) to use as single output. Note: Unit :mm[inch] General tolerances:±0.250mm[±0.010inch] Note: 1. The CTRL control pin voltage is referenced to GND. 2. Typical efficiency value at nominal input voltage and full load. 3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 4. In this datasheet, all the test methods of indications are based on corporate standards. 5. Capacitor MAX load tested at nominal input voltage and constant resistive load. http://www.microdc.cn Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 33of 3