Photoelectric sensors FSL 500C6Y00 Through beam fiber optics dimension drawing 32 ø 2,3 min. 13,2 12 23,4 L 28 general data photo type through beam sensor (liquid level sensor) actual range Sb 13 mm response time / release time 0,05 ... 5 ms max. outer diameter of the pipe / tube 3 ... 13 mm type of head (fiber optic cable) flach width / diameter (head) 32 mm height / length (head) 28 mm depth (head) 23,4 mm material (head) PC bending radius 4 mm cable jacket diameter 2,3 mm material cable jacket PFI material (fiber optic cable) plastic length (fiber optic cable) 5000 mm operating temperature -30 ... +70 °C Sensing distance/response time: For the definitive sensing distance/response time please see table below “fitting fiber optic sensors”. Detects liquids in (semi-)transparent stand pipes/hoses with 3 - 13 mm diameter. fitting fiber optic sensors actual range Sb (0,05 ms) actual range Sb (0,25 ms) actual range Sb (1 ms) actual range Sb (5 ms) FVDK 67 (standard version) 13 mm (HS) - 13 mm (nL) 13 mm (HP) FVDK 67 (2 adjustable outputs) 13 mm (HS) - 13 mm (nL) 13 mm (HP) FVDK 67 (master/slave) 13 mm (HS) - 13 mm (nL) 13 mm (HP) FVDK 66 (standard version) - 13 mm (FT) 13 mm (nL) - FVDK 66 (master/slave) - 13 mm (FT) 13 mm (nL) - FVDK 22 - - 13 mm (nL) - FVDK 12 - - 13 mm (nL) - FVDK 12 (fast version) 13 mm (HS) - - - FVDK 10 - - 13 mm (nL) - FWDK 84 (analog output) operating modes HS High Speed FT fast nL Standard HP High Sensitivity www.baumer.com 11/6/2015