RELIABILITY DATA LT1846 / LT1847 / LT3846 / LT3847 8/21/2006 • OPERATING LIFE TEST PACKAGE TYPE SAMPLE SIZE OLDEST DATE CODE CERDIP PLASTIC DIP NEWEST DATE CODE 139 8601 501 8639 640 • HIGHLY ACCELERATED STRESS TEST AT +131°C/85%RH PACKAGE TYPE SAMPLE SIZE OLDEST DATE CODE PLASTIC DIP 454 9207 454 • PRESSURE COOKER TEST AT 15 PSIG, +121°C PACKAGE TYPE SAMPLE SIZE PLASTIC DIP 525 525 • TEMP CYCLE FROM -65°C to +150°C PACKAGE TYPE SAMPLE SIZE CERDIP PLASTIC DIP SAMPLE SIZE NEWEST DATE CODE 8639 0137 OLDEST DATE CODE NEWEST DATE CODE OLDEST DATE CODE 1,088.85 1,800.79 2,889.64 K DEVICE (4) HOURS AT +85°C 9547 NEWEST DATE CODE 57 8739 504 8639 561 • THERMAL SHOCK FROM -65°C to +150°C PACKAGE TYPE 0212 9524 OLDEST DATE CODE CERDIP PLASTIC DIP K DEVICE HOURS (1) AT +125°C 630.84 630.84 NEWEST DATE CODE 25.80 25.80 K DEVICE CYCLES 5.70 322.41 328.11 K DEVICE CYCLES 57 8739 0019 595 8639 9322 652 (1) Assumes Activation Energy = 1.0 Electron Volts (2) Failure Rate Equivalent to +55°C, 60% Confidence Level = 1.40 FITS (3) Mean Time Between Failures in Years = 81,484 (4) Assumes 20X Acceleration from 85°C to +131°C Note: 1 FIT = 1 Failure in One Billion Hours. Form: 00-03-6209B. R116 0 1 1 NUMBER OF FAILURES 0 0 NUMBER OF FAILURES K DEVICE HOURS 0019 9319 NUMBER OF (2) FAILURES 0.86 544.33 545.19 0 0 NUMBER OF FAILURES 0 0 0 NUMBER OF FAILURES 0 0 0 Rev 24