EVERY BUILDING MATTERS RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 www.panasonicair.com.au • Specifications are subject to change without prior notice for further improvement • The contents of this catalogue are effective as of June 2015. April, 2012 • Due to printing considerations, the actual colours may vary slightly from those shown • All graphics are provided merely for the purpose of illustrating a point. EVERY BUILDING MATTERS A Better Life, A Better World As we move towards our Centenary in 2018, our new brand slogan encapsulates Panasonic’s vision of expanding and pursuing a better life for each of our customers. Working with our many partners, we operate in a wide range of fields such as the home, community, business and travel realising a better world globally through its contribution to the environment and other activies, in both its B2C and B2B businesses. 2 3 For Future Generations Panasonic aims to become the No.1 green innovation company in the electronics industry The 2014 Best Global Green Brands 2014 Brand Ranking Top 10 1 FORD 2 TOYOTA 3 HONDA 4 NISSAN 5 6 NOKIA 7 SONY 8 ADIDAS 9 DANONE 10DELL Interbrand has announced its 2014 ranking of Best Global Green Brands. In this year’s ranking Panasonic was ranked number five, fulfilling our eco pledge “For future generations, Panasonic aims to become the No.1 Green Innovation Company in the Electronics Industry.” At Panasonic, our eco pledge is more than just a tagline; it’s a harmonious way of life that we take very seriously. Panasonic was founded based on the philosophy of contributing to progress in society and to enriching people’s lives through business activities. By offering products that help people lead better, greener lives, we are making good on our strong commitment to continuous environmental sustainability management. Interbrand’s Best Global Green Brands 2014 report is a look at sustainability with performance data powered by Deloitte and consumer perception data. Interbrand evaluates organisations based on market perception; actual environmental performance; and products and services.* S ource: Best Global Green Brands 2014, Interbrand. Go to www.bestglobalgreenbrands.com for more information. Panasonic Eco City Tianjin, China 4 5 Panasonic Air Conditioning Designed To Care For Your Projects With more than 30 years of experience, exporting to more than 120 countries around the world, Panasonic is unquestionably one of the leaders in the air conditioning sector. The company is also a world leader in innovation as it has filed more than 91,539 patents to improve its customers’ lives. Moreover, Panasonic is determined to remain at the forefront of its market. In all, the company has produced more than 200 million compressors and its products, particularly residential air conditioners, now hold the No. 1 market share in Japan and other major countries in Asia. You can be assured of the extremely high quality of Panasonic’s air conditioners. This wish to excel has made Panasonic the international leader in air conditioning solutions. The company’s industrial capacity and firm commitment to the environment has enabled it to open new avenues of research and to develop innovative technologies which enhance its customers’ way of life. Panasonic offers a range of turnkey air conditioning solutions for homes, medium-sized buildings such as offices and restaurants. These offer maximum effectiveness, comply with the strictest environmental standards and meet the most avant-garde construction requirements of our time. At Panasonic we know what a great responsibility it is to install cooling and heating systems. Because offering you the best solutions in cooling and heating matters. EVERY BUILDING MATTERS WHAT’S NEW Exclusive Feature 1 Using sensors and precise control programs, ECONAVI analyses room conditions and adjusts cooling and heating power to reduce wasted electricity. Exclusive Feature 2 Deluxe Wired Remote Controller Features a large LCD and touch keys for easy operation, and multiple energy-saving functions. 6 CONTENTS Introduction 02 - 07 Exclusive Features 08 - 13 Product Range 14 - 15 Outdoor Units 16 - 21 Indoor Units High Static Pressure Ducted type 22 - 27 Mid Static Pressure Ducted type 28 - 31 4-Way Cassette type 32 - 35 Under Ceiling type 36 - 39 Controllers 40 - 47 7 Exclusive Feature 1 ECONAVI reduces inefficient air conditioning Providing outstanding energy-saving performance, Panasonic's large capacity air conditioners can be connected to ECONAVI to detect when energy is being wasted. ECONAVI senses the presence or absence of people and the level of activity in each area of a room. When unnecessary heating or cooling is detected, indoor units are individually controlled to match room conditions for energy-saving operation. Detection of the level of activity enables optimum power saving Sensors are remotely located to maximise the energy-saving effect Presence or absence of people and the level of activity in the room are detected in real time. Set temperature is automatically adjusted to optimise the power consumption. When sensors are built into the indoor unit, pillars, walls, cabinets and other fittings can obstruct the sensors, reducing the area of detection and lowering the energy-saving effect. Panasonic sensors can be located any where in the room which enables the optimum layout for sensors in any location. Case study at coffee shop Mid Static Duct -60° In the morning 4-way Cassette Under Ceiling Reduced cooling when tthere are fewer people -20° Applicable to all 4 types of indoor units* 0° 20° Wide 120˚ 2.5m In the afternoon Detection area Thorough cooling when there is a high level of activity Approx 1m A Automatic Thermo Off depending on conditions at tthe end of the day* High Static Duct 60° 40° -40° *Depending on conditions, the setting can change to Switch Off After 3 Hours, Thermo Off or Temperature Shift. 7m Dead Zone AAt night ECONAVI Sensor CZ-CENSC1 1m 3m 5m 7m Wide detection area A sensor is remotely set to maximise the detection area. Installation flexibility ready for indoor unit layout changes. *Except 20.0kW Up to 28% verified energy-saving* With the set temperature increased by 2°C during cooling. Test method Test conditions *ECONAVI sensor allows energy saving by allowing set temperature to increase by up to 2°C during times when lower levels of human activity or human presence are detected. Tested with a uniform level of human activity and with doors opened and closed a uniform number of times. At each set temperature between 24°C and 28°C, cumulative power consumption over 3 hour period measured and compared. Maximum possible energy saving is 28% based upon the power consumption difference. *Panasonic test room (29m2). Indoor unit: S-100PU1 (Single 4-way Cassette 10kW) Outdoor unit: U-100PE1 (Single DLX 10kW). Cooling operation, set temperature of 24 to 28°C, Hi airflow setting. EXAMPLE 1 EXAMPLE 2 In a coffee shop power is reduced to match the number of customers in each area. In an apartment, power output is adjusted to match the number of people present in each room. Gentle cooling in areas of low activity WALK-IN CLOSET MASTER A ER BEDROOM BATH BALCONY SEATING AREA BEDROOM COUNTER TABLE KITCHEN : : ENTRANCE Indoor units (3) Sensors (3) Thorough cooling in areas of high activity BALCONY Gentle cooling in areas of low activity LIVING Thorough cooling in areas of high activity : 8 Indoor units (3) : Grilles (3) Sensors (3) : ENTRANCE 9 Exclusive Feature 2 Deluxe Wired Remote Controller Easy-to-use, with multiple energy saving functions at your fingertips. Energy consumption display and Log function Energy Consumption Monitoring Display Graphs of daily, weekly and annual power consumption are displayed. A visual representation of power consumption lets you confirm the energy-saving effect and quickly detect energy-wasting operation. This helps to further improve energy saving. Day Week Month Multiple control settings to meet a wide range of air conditioning needs Temperature Auto Return Actual size 1 Large 3.5" Full-dot LCD with White LED Backlight Characters and icons are clearly displayed for improved visibility. The display is also large enough to provide a wide range of information for easy confirmation of operation conditions. 10 2 Even if you change the temperature setting, after a set time it automatically returns to the original temperature setting. You can set temperature auto return time in 10-minute intervals within a period of 4 hours. Stylish, Easy-to-use Touch Key Design The elegant, flat design features large touch keys in a simple layout enabling easy, intuitive operation. Temperature Setting Range Limitation You can set the upper and lower temperature limits. Doing this helps reduce power consumption due to over cooling or heating. Setting is possible in the Cooling, Heating and Dry modes. Auto Shutoff Air conditioning automatically stops after a set time, so you don’t have to worry about forgetting to switch the unit off. Even if you manually switch the unit back on after it has stopped, it automatically switches off again after the set time. 11 Exclusive Feature Hi-Spec Remote2Con- Function List Wide range of controls for extra convenience Individual Louver Control (For 4-way cassette U1 type) One of the 4-directional outlets can be selected and locked to provide efficient air distribution that matches the indoor unit layout. Indoor units can be set individually. Weekly Timer This lets you specify 8 Start/Stop times and temperature presets for each day of the week. Service Contact Address Once you have registered service contact details, they are automatically displayed if a problem with the air conditioner occurs. This helps you quickly deal with the situation. Convenient Controls Operation Lock Operation keys can be locked to prevent users accidentally changing the temperature setting, airflow rate, airflow direction and other settings. Maintenance Function Display of outdoor malfunction data, service contact details, filter cleaning remaining time and other data enables at-aglance verification of maintenance information with the remote controller. Filter Information Filter information is indicated for cleaning after a set time of operation has passed. The number of hours can be adjusted. Repeat OFF Timer Quiet Operation Mode Setting Information Lists There’s a Quiet mode that reduces the outdoor unit’s operating noise. The mode can be switched On/Off and the Start/End times can be set with the remote controller. 12 You can set the unit to switch off after a desired period of time. Information concerning current settings is displayed in the remote controller’s LCD for easy confirmation. 13 Panasonic provides ideal solutions for large-capacity air conditioning needs. CAPACITY (kW) 6.0kW Ducted S-60PE1R5A 7.1kW 10.0kW 12.5kW 14.0kW 20.0kW S-71PE1R5A S-100PE1R5A S-125PE1R5A S-140PE1R5A S-200PE2R5 NEW High Static Pressure Model Indoor Unit Page 22-25 for 6.0kW-14.0kW Page 26-27 for 20.0kW Ducted ECONAVI ready (Except for 20.0kW) NEW S-60PF1R5A NEW S-71PF1R5A NEW S-100PF1R5A NEW S-125PF1R5A NEW S-140PF1R5A NEW Mid Static Pressure Model Page 28-31 ECONAVI ready 4-Way Cassette S-60PU1R5A S-71PU1R5A S-60PT2R5A S-71PT2R5A 7.1kW S-100PU1R5A S-125PU1R5A S-140PU1R5A S-100PT2R5A S-125PT2R5A S-140PT2R5A 10.0kW 12.5kW 14.0kW 20.0kW U-125PE1R5A U-125PE1R8A* U-140PE1R5A U-140PE1R8A* U-200PE1R8* * Panel is provided as an option (CZ-KPU21) Page 32-35 ECONAVI ready Under Ceiling Page 36-39 ECONAVI ready CAPACITY (kW) Outdoor Unit 14 Page16-21 EVERY BUILDING MATTERS 6.0kW U-60PE1R5A U-71PE1R5A U-100PE1R5A U-100PE1R8A* NEW (*3-phase) 15 Outdoor Unit Outdoor Unit DC Inverter allows better comfort and energy savings • Complies with all necessary Safety Approvals to ensure quality and safety • Top-class EER:4.20 / COP:4.31 (4 Way Cassette type:10.0kW) • Demand Response (DRED) compatible • Cooling operation is possible when outdoor temperature as high as 46°C • DC inverter technology combined with R410A for excellent efficiency • Maximum piping length:180m • Cooling operation is possible when outdoor temperature as low as -15°C*1 • Heating operation is possible when outdoor temperature as low as -25°C*2 • One ampere starting current • Auto restart from outdoor unit Product Quality and Safety All Panasonic air conditioners undergo strict quality and safety tests before sale. This rigorous process includes obtaining all necessary Safety Approvals, to ensure that all air conditioners we sell are not only built to the highest market standards, but are also completely safe. *1 Except 20.0kW *2 20.0kW only Energy-saving concept The use of energy saving design for the structure of fans, fan motors, compressors and heat exchangers resulted in high COP value which ranked as one the top class in the industry. In addition, use of highly efficient R410A refrigerant reduces CO2 emission and lowers operating costs. 5 4 3 2 Compressor A large inverter compressor has been adopted. The inverter compressor is superior in performance with improved partial-load capacity. Printed Circuit Board (S-LINK) The number of PCB was reduced from 3 into 2* pieces to improve maintenance work. Compact & 1 High Efficient 2 3 DC Fan Motor Checking load and outside temperature, the DC motor is controlled for optimum air volume. New Large 4 Diagonal (520mm) Air Flow Fan The newly designed fan has been developed to inhibit air turbulence and to increase efficiency. As fan diameter has been increased to 520mm*, the air volume has been increased whilst maintaining a low sound level. High-Efficiency Heat Exchanger The heat exchanger and the size of the copper tube in the heat exchanger has been redesigned to increase efficiency. 1 5 *Except for 20.0kW 16 17 Outdoor Unit Outdoor Unit Improved Energy Saving Demand Response Compliant The operation efficiency has been improved using highly efficient R410A refrigerant, new DC inverter compressor, new DC motor and new design of heat exchanger. Panasonic air conditioners are equipped with a Demand Response Enabling Device (DRED) which complies to both AS 4755 and AS 3823. Panasonic continues to design and develop products that are tailored to local needs and requirements. This ensures that Panasonic products that you are installing today are compliant with the demand response standards that are likely to be implemented shortly. Cooling (Ducted) Heating (Ducted) Cooling 4.4 4.4 Previous 4.3 PE1 PF1 PE2 4.2 4.10 4.1 4.0 PE1 PF1 PE2 4.02 4.0 3.90 3.9 3.84 3.8 3.7 3.7 3.6 3.6 3.50 3.5 3.4 3.5 3.36 3.3 3.24 3.23 3.31 3.26 3.25 3.21 3.2 3.01 3.87 3.9 3.8 3.0 Previous 4.2 4.1 3.1 4.31 4.3 3.60 3.41 3.41 3.42 3.48 3.45 3.52 3.52 3.32 3.3 3.68 3.37 3.34 3.15 Outdoor unit 2.9 Demand control terminal is available to control 0-50-75-100% of capacities. 2.8 2.7 2.7 7.1kW 10.0kW 12.5kW Demand controller 3.0 2.77 6.0kW C Terminal block 3.1 2.9 2.8 DRM1 DRM2 DRM3 3.2 3.01 3.01 3.4 3.85 The Equipment Energy Efficiency (E3) program has been supporting the development of Demand Response Enabling Device (DRED) standards for airconditioners which should comply with AS 4755. DRED functionality is not compulsory today, however, this capability will be required for all installations in the very near future 14.0kW 20.0kW 6.0kW 7.1kW 10.0kW 12.5kW 14.0kW Wide Operating Range 20.0kW Compact and Lightweight • Cooling operation is possible when outdoor temperature as low as -15°C*1 • Cooling operation is possible when outdoor temperature as high as 46°C • Heating operation is possible when outdoor temperature as low as -25°C*2 The remote controller temperature setting offers a range from 16°C to 30°C. The weight is only 98 kg. (10.0kW, 12.5kW, 14.0kW) Hence it is easy to carry, easy to install. Lightweight 98 kg *1 Except 20.0kW *2 20.0kW only Cooling: -15°C DB to 46°C DB Heating: -20°C WB to 24°C WB Except 20.0kW Compact & Flexible-design Cooling: -10°C DB to 46°C DB Heating: -25°C WB to 15°C WB The slim and lightweight design can be installed in various places. * 14.0kW or smaller capacity unit For 20.0kW Increased Piping Length for Greater Design Flexibility Adaptable to various building types and sizes Max. piping length : 50m (6.0kW, 7.1kW), 75m (10.0kW, 12.5kW, 14.0kW), 180m (20.0kW) 18 Single Split FS Multi Quiet Mode Quiet mode reduces outdoor operating sound by 5dB. External input signal is also available. * 14.0kW or smaller capacity unit 19 Outdoor Unit Outdoor Unit Air intake 300 380.5 Air discharge 61 Enlarged view A 15 75.5 5 41 8 7 8 4 26 View Z D Electrical component box Air discharge 9 35 Mounting hole, anchor bolt:M10 Refrigerant piping (liquid pipe),flared connection (ø9.52) Refrigerant piping (gas pipe),flared connection (ø15.88) Refrigerant piping hole Electrical wiring port (ø13) Electrical wiring port (ø22) Electrical wiring port (ø27) Electrical wiring port (ø35) Installation hole 8 - 15 x 21 elongated hole 835 853 4 8 856 39 81 48 462 120 1) 2) 3) 4) 5) 6) 7) 8) B 84.5 109.5 unit: mm View B 8 60 10 64 182 7 120 430 39 6 12 Z 363 15 930 Enlarged view D 601 71 Dimensions (10.0kW – 14.0kW) 340 5 5 20 6 7 8 4 26 60 35 86 39 81 48 120 522 48 81 120 39 490 6 8 60 84.5 109.5 35 4 4 1) 2) 3) 4) 5) 6) 7) 8) 2 1 2 ) 1 Mounting hole, anchor bolt:M10 Refrigerant piping(liquid pipe),flared connection (ø9.52) Refrigerant piping(gas pipe),flared connection (ø15.88) Refrigerant piping hole Electrical wiring port (ø13) Electrical wiring port (ø22) Electrical wiring port (ø27) Electrical wiring port (ø35) 56 Refrigerant tubing & electrical wiring port (Bottom plate dimension) 220 355 458 585 646 222 Types of unit Refrigerant tubing (gas tube) Refrigerant tubing (liquid tube) 20.0kW brazed connection flared connection ø19.05 ø9.52 3 Installation holes(8-15x21 elongated holes), anchor bolts M12 or larger 4 Refrigerant tubing port (front: knock-out hole) 5 Refrigerant tubing port (bottom: slit hole) 6 Electrical wiring port (front: ø60, ø28 knock-out hole - for conduit connection) Electrical wiring port (bottom: ø60, ø28 knock-out hole - for conduit connection) Pressure outlet port (for high pressure: ø7.94 Schrader-type connection) Pressure outlet port (for low pressure: ø7.94 Schrader-type connection) 7 64 unit: mm B 6 92 74 278 347 42 View B 7 Position of refrigerant tube connection 90 Air intake Air discharge 5 Handle 7 Space for creation of hole on-site (Max. diameter ø48) 4 3 8 152 137 66 1416 2 Enlarged view E 51 16 40 68.5 Hole (Bottom) 2 47 6 35 75.5 41 According to the installation site, you may choose the setting position in the depth direction of the anchor bolt from "A", "B" or "C". A : 894 (Installation hole pitch) * The tubing is routed out from the front. B : 730 (Installation hole pitch) * The tubing is routed out from the bottom. C : 730 (Installation hole pitch) 1 Enlarged view A Refrigerant piping end connection 2-18x13 Anchor hole 62 57.5 4 77 Air discharge 61 197 33 23 5 2 31.5 Air intake 5 63 (part Space for piping,wiring and maintenance 173 13 Installation fixing bracket Installation side 477 326 191 Space for piping, wiring and maintenance Side view 120 940 1 Anchor hole 18 41 340 A Air intake 76 2-U shaped hole 300 150 200 or more 100 or more 620 380.5 170 71 628 Front view 500 or more 18 42 90 7 48 81 5 11 1758 1654 996 4 6 60 35 86 no 8k ø2 120 16 Air intake Air discharge 3 5 Handle 0k ø6 68.5 Hole (Bottom) 173 62 e hol e out hol t -ou ck knoc Top view 47 6 51 340 3 740 (Installation hole pitch) 770 unit: mm 5 E 57.5 Refrigerant piping end connection 2-18x13 Anchor hole 2 Air intake (104) 13 35 1 40 940 31.5 Air intake 7 930 Space for piping,wiring and maintenance 18 41 340 A Air intake Anchor hole B 200 or more A 500 or more 2-U shaped hole 76 150 100 or more 620 Air intake 18 Unit:mm 170 Dimensions (20.0kW) Space for piping, wiring and maintenance C Dimensions (6.0kW – 7.1kW) 8 9 10 Knock-out hole for connecting pressure gauge (optional) 11 Terminal plate 12 Terminal plate for inter-unit control wiring 21 High Static Pressure Ducted Indoor Unit High Static Pressure Ducted ECONAVI ready High static and large airflow ducted for exceptional installation flexibility. NEW ECONAVI ready CZ-CENSC1 S-60PE1R5A S-71PE1R5A S-100PE1R5A CZ-RTC3 CZ-RTC4 S-125PE1R5A S-140PE1R5A Cold Drafts Reduced During Heating Operation Compact Body Size Hidden in the ceiling, ideal when interior decor is an important consideration such as in residences with many rooms and light commercial buildings. 1,100 mm • Accurate temperature measurement by E1/E2 sensor to reduce cold drafts during heating operation. 1,100 700 mm mm 700 mm Air intake sensor E2 sensor 430 E1 sensor mm 290 mm (60PE) 360 mm (71PE, 100PE) 60PE, 71PE, 100PE 125PE, 140PE System Example An inspection port (450 mm x 450 mm or more) is required at the control-box side of the indoor unit body. Rectangle duct Inspection port (450 x 450 mm or more) 22 Canvas duct Intake grille 23 High Static Pressure Ducted Indoor Unit High Static Pressure Ducted Dimensions Optional Controller Dimensions: mm model A B C D S-60PE1R5A 130 33.1 290 118 S-71PE1R5A S-100PE1R5A 195 35.7 360 50 S-125PE1R5A S-140PE1R5A 260 38.2 430 121.5 2.Gas side (O.D.ø15.88 FLARE) 2.Gas side (O.D.ø15.88 FLARE) ECONAVI sensor CZ-CENSC1 3.Drain pipe size (O.D.ø32) 3.Drain pipe size (O.D.ø32) 1.Liquid side (O.D.ø9.52 FLARE) NEW Deluxe Wired remote controller CZ-RTC3 1.Liquid side (O.D.ø9.52 FLARE) Timer remote controller CZ-RTC4 Simplified remote controller CZ-RE2C2 Wireless remote controller CZ-RWSK2 + CZ-RWSC3 Capacity Model Name 6.0kW 7.1kW 10.0kW Indoor Unit S-60PE1R5A S-71PE1R5A S-100PE1R5A S-100PE1R5A S-125PE1R5A S-125PE1R5A S-140PE1R5A S-140PE1R5A Outdoor Unit U-60PE1R5A U-71PE1R5A U-100PE1R5A U-100PE1R8A U-125PE1R5A U-125PE1R8A U-140PE1R5A U-140PE1R8A 3 Phase/ 50Hz Power source Cooling capacity : Heating capacity 12.5kW 14.0kW Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 1 Phase/ 50Hz V 230V | 240V 230V | 240V 230V | 240V 400V | 415V 230V | 240V 400V | 415V 230V | 240V 400V | 415V kW 6.0 (2.5 - 7.1) 7.0 (2.0 - 8.0) 7.1 (2.5 - 8.0) 8.0 (2.0 - 9.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0) 14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0) BTU/h 20,500 (8,500 - 24,200) 23,900 (6,800 - 27,300) 24,200 (8,500 - 27,300) 27,300 (6,800 - 30,700) 34,100 (11,300 - 42,700) 34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800) 38,200 (14,000 - 47,800) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400) 47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400) W/W 3.24 : 3.41 3.23 : 3.48 3.36 : 3.52 3.36 : 3.52 3.21 : 3.37 3.21 : 3.37 3.15 : 3.52 3.15 : 3.52 Cooling : Heating kW 1.85 : 2.05 2.20 : 2.30 2.98 : 3.18 2.98 : 3.18 3.90 : 4.16 3.90 : 4.16 4.45 : 4.55 4.45 : 4.55 Current Cooling : Heating A 0.85 : 0.85 | 0.86 : 0.86 1.24 : 1.24 | 1.25 : 1.25 1.72 : 1.72 | 1.74 : 1.74 1.72 : 1.72 | 1.74 : 1.74 1.82 : 1.82 | 1.84 : 1.84 1.82 : 1.82 | 1.84 : 1.84 2.62 : 2.62 | 2.70 : 2.70 2.62 : 2.62 | 2.70 : 2.70 Dimensions H×W×D mm 290×1,100 (+100)×700 360×1,100 (+100)×700 360×1,100 (+100)×700 360×1,100 (+100)×700 430×1,100 (+100)×700 430×1,100 (+100)×700 430×1,100 (+100)×700 430×1,100 (+100)×700 kg 35 42 44 44 48 48 53 53 L/s 366 : 366 500 : 500 666 : 666 666 : 666 833 : 833 833 : 833 1,000 : 1,000 1,000 : 1,000 Pa 70 (Max.100) 100 (Max.150) 100 (Max.150) 100 (Max.150) 100 (Max.150) 100 (Max.150) 100 (Max.150) 100 (Max.150) EER : COP Total power input Indoor Unit Net weight Air volume Cooling : Heating External static pressure Sound pressure level (H/M/L) Cooling : Heating dB(A) 43 / 41 / 40 : 43 / 41 / 40 45 / 44 / 43 : 45 / 43 / 44 48 / 46 / 44 : 48 / 46 / 44 48 / 46 / 44 : 48 / 46 / 44 Sound power level (H/M/L) Cooling : Heating dB(A) 60 / 58 / 57 : 60 / 58 / 57 62 / 61 / 60 : 62 / 61 / 60 70 / 68 / 66 : 70 / 68 / 66 70 / 68 / 66 : 70 / 68 / 66 71 / 69 / 67 : 71 / 69 / 67 71 / 69 / 67 : 71 / 69 / 67 73 / 71 / 69 : 73 / 71 / 69 73 / 71 / 69 : 73 / 71 / 69 3 3 3 3 3 3 3 3 mm VP-25 VP-25 VP-25 VP-25 VP-25 VP-25 VP-25 VP-25 Number of fan speed Drain pipe size 49 / 47 / 45 : 49 / 47 / 45 49 / 47 / 45 : 49 / 47 / 45 51 / 49 / 47 : 51 / 49 / 47 51 / 49 / 47 : 51 / 49 / 47 Outdoor Unit Current Cooling : Heating A 7.85 : 8.80 | 7.65 : 8.60 9.10 : 9.30 | 8.80 : 9.00 11.8 : 12.7 | 11.40 : 12.3 3.95 : 4.25 | 3.80 : 4.10 16.0 : 17.2 | 15.4 : 16.6 5.30 : 5.70 | 5.10 : 5.50 17.8 : 18.1 | 17.2 : 17.5 5.80 : 5.95 | 5.55 : 5.70 Dimensions H×W×D mm 996 × 940 × 340 996 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 Net weight 24 kg 68 69 98 98 98 98 98 98 Air volume Cooling : Heating L/s 1,000 : 1,000 1,000 : 1,000 1,833 : 1,583 1,833 : 1,583 2,166 : 1,833 2,166 : 1,833 2,250 : 2,000 2,250 : 2,000 Sound pressure level (Silent mode) Cooling : Heating dB(A) 48 (46) : 50 (48) 48 (46) : 50 (48) 52 (50) : 52 (50) 52 (50) : 52 (50) 53 (51) : 53 (51) 53 (51) : 53 (51) 54 (52) : 55 (53) 54 (52) : 55 (53) Sound power level (Silent mode) Cooling : Heating dB(A) 65 (63) : 67 (65) 65 (63) : 67 (65) 69 (67) : 69 (67) 69 (67) : 69 (67) 70 (68) : 70 (68) 70 (68) : 70 (68) 71 (69) : 71 (69) 71 (69) : 71 (69) Piping connections Liquid/Gas m Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Pipe length min. - max. m 5 - 50 5 - 50 5 - 75 5 - 75 5 - 75 5 - 75 5 - 75 5 - 75 Elevation difference (OU located lower, OU located higher) m 15, 30 15, 30 15, 30 15, 30 15, 30 15, 30 15, 30 15, 30 Maximum chargeless length m 30 30 30 30 30 30 30 30 Refrigerant at shipping, Additional gas amount g R410A 2,000, 50 (g/m) R410A 2,350, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) Operation ranges ˚C -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 Cooling : Heating 25 High Static Pressure Ducted Indoor Unit High Static Pressure Ducted NEW NEW High static and large airflow ducted for exceptional installation flexibility. CZ-RTC4 CZ-RTC3 S-200PE2R5 DC motor Mild dry Automatic Restart Function Technical focus Sensible cooling 5-10% improved • Discharge air temperature control to reduce cold drafts during heating operation • Configurable air temperature control New heat exchanger with φ7mm pipe that increases the heat transfer surface to improve sensible cooling (5-10% improvement) Discharge air temperature control 3-step static pressure set up You can select between the three Static Pressure modes of 270 Pa / 140 Pa / 72 Pa for extra installation flexibility. 72Pa Factory Setting 140Pa 270Pa • Equipped with 4 sensors (Intake/ Discharge) • Able to control discharge air temperature for accurate room temperature control. • Possible to reduce cold drafts during heating operation. E1 sensor Max. 270 Pa static pressure setting Air discharge sensor A maximum static pressure setting of a high 270 Pa enables the use of long ducts for installation in a wide range of spaces. Ideal for large-scale offices, restaurants and other facilities. W/W 3.31 : 3.68 kW 6.05 : 6.09 479 300 100 100 3 A 3.20 : 3.20 | 3.10 : 3.10 mm 479×1,453×1,205 kg 106 Cooling : Heating L/s 1,200 / 1,050 / 883.33 : 1,200 / 1,050 / 883.33 Pa 72 (Max.270) Air volume External static pressure 45 Sound pressure level (H/M/L) Cooling : Heating dB(A) 47 / 45 / 42 : 47 / 45 / 42 Sound power level (H/M/L) Cooling : Heating dB(A) 79 / 77 / 74 : 79 / 77 / 74 Phase/Hz 3 Phase/ 50Hz V 400V | 415V 28- 26 100 100 60 320 434 Approx.200 41 Inspection port 600 67 9×100 pitch=900 964 1200 (suspension bolt pitch) 67 Inspection port 8 422 600 26- 3.2 holes (entire circumference) 1310 610 or more (service space) Cooling : Heating A 8.60 : 8.80 | 8.30 : 8.50 Dimensions H×W×D mm 1,758 × 770 × 930 kg 234 Air volume Cooling : Heating L/s 2,450 Piping connections Liquid / Gas mm (inch) Ø9.52 (3/8) / Ø19.05 (3/4)* Pipe length min. - max. m 7.5 - 180 Elevation difference (OU located lower, OU located higher) m 40, 50 Operation ranges ˚C -10 to 46: -25 to 15 Cooling : Heating 467 Ceiling Surface Current Net weight 7 3.2 holes 4-37×12 holes (for suspension bolts) Outdoor Unit Power source 600 or more (service space) 1310 1070 10×10 pitch=1000 1 1220 Cooling : Heating H×W×D 132 2 1205 Current Dimensions 77 6 Indoor Unit Net weight 800 or more (service space) 40 50 156 60 76,400 (20,500 - 85,300) 23 1138 Cooling : Heating 68,200 (23,900 - 73,400) 1100 1170 EER : COP 22.4 (6.0 - 25.0) 27 5 (suspension bolt pitch) BTU/h 20.0 (7.0 - 21.5) 4 1 Refrigerant piping (liquid pipes) Ø9.52 2 Refrigerant piping (gas pipes) 76 type: Ø19.05, 96 type: Ø22.22 3 Power supply outlet (Ø25 grommet, rubber) 4 Power supply outlet (spare) (Ø30 knock-out) 5 Optional outlet for piping 6 Drain port 25 A, male thread 7 Duct connection for suction 8 Duct connection for discharge 65 230V | 240V 479 1 Phase/ 50Hz V kW Cooling capacity : Heating capacity Total power input Phase/Hz 264 Power source HIGH STATIC DUCTED Dimensions 43 U-200PE1R8 207 S-200PE2R5 Outdoor Unit 45 Model Name 20.0kW Indoor Unit 131 Capacity Air intake sensor E3 sensor 60 • Design flexibility thanks to high static pressure and large air volume • DC motor equipped • Low power input 467 Automatic Fan Operation 1100 or more (service space) Self-diagnosing Function * Tubing size is Ø12.70 (1/2) / Ø22.22 (7/8) when the length is over 90m. Please refer to technical documents for more details. 1334 1453 27 Mid Static Pressure Ducted Indoor Unit Mid Static Pressure Ducted NEW Provides exceptional performance, super quiet operation and the ultimate in control. A perfect solution when ceiling heights are restricted. ECONAVI ready ECONAVI ready CZ-CENSC1 DC motor Self-diagnosing Function Automatic Fan Operation Mild dry Automatic Restart Function NEW S-60PF1R5A S-71PF1R5A CZ-RTC3 CZ-RTC4 S-100PF1R5A S-125PF1R5A S-140PF1R5A Built-in Drain Pump Technical focus • Space saving 290mm height • DC fan motor for variable external static pressure control • Easy to install and maintain • Air off sensor avoids cold air drafts during heating operation • Configurable air temperature control Built-in Drain pump (DC motor pump) External electrical equipment box makes maintenance easy Space saving height of 290mm for all models 290mm standardised height provides easy and uniform installation for models with different capacities, especially when ceiling heights are restricted. Variable external static pressure control Optimal airflow set-up is possible for different ducting design and conditions. • Built-in filter • Side removable filter Optimal Control by DC Motor For short ducting such as hotels 10Pa 150Pa For long ducting or for usage with high density filter * Please refer to technical databook for detail. System example Discharge air temperature control Canvas duct Rectangle duct *Before spec-in, please consult with an authorised Panasonic dealer. An inspection port (450 mm x 450 mm or larger) is required at the lower side of the indoor unit body. Intake grille Inspection port (450 x 450 mm or more) Up to 300 mm Air intake sensor E2 sensor E1 sensor V-shaped heat exchanger To improve heat exchange efficiency, an original V-shaped heat exchanger was developed incorporating a conventional high-efficiency fan and high-efficiency grooved heat transfer tubes. This increases the heat exchange surface area by about 80%. More powerful drain pump Using a high-lift built-in drain pump, drain piping can be elevated up to 702 mm from the base of the unit. • Possible to control discharge air temperature for accurate room temperature control. • Possible to reduce cold drafts during heating operation. Increases surface area by about 30 to 80% Up to 500 mm 202 mm 28 29 Mid Static Pressure Ducted Indoor Unit Mid Static Pressure Ducted MID STATIC DUCTED Dimensions SIZE 100,125,140 PF1R5A 9 Dimensions: mm 186 min.250 54 1192(Flange O.D.) (75) 140 186 290 23 300 2 Min.400 77 Dimensions: mm 154 Inspection access 450 × 450 Indoor unit Refrigerant tubing Min.650 6.0KW 7.1KW 10.0KW S-60PF1R5A S-71PF1R5A S-100PF1R5A S-100PF1R5A S-125PF1R5A S-125PF1R5A S-140PF1R5A S-140PF1R5A Outdoor Unit U-60PE1R5A U-71PE1R5A U-100PE1R5A U-100PE1R8A U-125PE1R5A U-125PE1R5A U-140PE1R5A U-140PE1R8A 3 Phase/ 50Hz Cooling : Heating 33 (150) Electrical component box Indoor Unit EER : COP 113 65 256 1400 1467(Suspension bolt pitch) 23 27 2 290 Min.650 Cooling capacity : Heating capacity 130 70 30 20 71 27 154 150 186 792(Flange O.D.) 20-ø3holes 150 x 7 = 1050 32 30 300 113 65 186 1 77 30 20 27 23 636 54 Refrigerant tubing Power source Total power input 140 8 5 (75) Electrical component box Capacity Model Name 23 27 Min.250 33 (150) Inspection access 450 × 450 Indoor unit Min.400 636 min.250 21 1000 1067(Suspension bolt pitch) 71 70 Min.250 21 130 150 150 x 5 = 750 5 1 32 30 256 89 16-ø3holes 4 89 7 8 26 700 636 700 7 4 3 758 26 700 636 700 758 35 280 32 28 9 3 6 172 32 6 35 280 1 Refrigerant piping joint (liquid tube) Ø9.52 Flare 2 Refrigerant piping joint (gas tube) Ø15.88 Flare 3 Upper drain port VP25 (O.D. Ø32 mm) 200 flexible hose supplied 4 Bottom drain port VP25 (O.D. Ø32 mm) 5 Suspension lug (4-12 × 30 mm) 172 6 Power supply outlet 7 Fresh air intake port (Ø150 mm) 8 Flange for flexible air outlet duct 9 Electrical component box Filter 1 Refrigerant piping joint (liquid tube) Ø9.52 Flare 2 Refrigerant piping joint (gas tube) Ø15.88 Flare 3 Upper drain port VP25 (O.D. Ø32 mm) 200 flexible hose supplied 4 Bottom drain port VP25 (O.D. Ø32 mm) 5 Suspension lug (4-12 × 30 mm) 6 Power supply outlet 7 Fresh air intake port (Ø150 mm) 8 Flange for flexible air outlet duct 9 Electrical component box Filter 28 SIZE 60, 71 PF1R5A 12.5KW 14.0KW Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 1 Phase/ 50Hz V 230V | 240V 230V | 240V 230V | 240V 400V | 415V 230V | 240V 400V | 415V 230V | 240V 400V | 415V kW 6.0 (2.5 - 7.1) 7.0 (2.0 - 8.0) 7.1 (2.5 - 8.0) 8.0 (2.0 - 9.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0) 14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0) BTU/h 20,500 (8,500 - 24,200) 23,900 (6,800 - 27,300) 24,200 (8,500 - 27,300) 27,300 (6,800 - 30,700) 34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800) 34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400) 47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400) W/W 3.90 : 3.87 3.84 : 3.85 4.10 : 4.31 4.10 : 4.31 3.50 : 4.02 3.50 : 4.02 3.25 : 3.60 3.25 : 3.60 kW 1.54 : 1.81 1.85 : 2.08 2.44 : 2.60 2.44 : 2.60 3.57 : 3.48 3.57 : 3.48 4.31 : 4.44 4.31 : 4.44 Indoor Unit Current Cooling : Heating A 0.89 : 0.89 | 0.87 : 0.87 0.89 : 0.89 | 0.87 : 0.87 1.30 : 1.34 | 1.27 : 1.29 1.30 : 1.34 | 1.27 : 1.29 1.44 : 1.42 | 1.39 : 1.38 1.44 : 1.42 | 1.39 : 1.38 1.50 :1.50 | 1.47 : 1.46 1.50 :1.50 | 1.47 : 1.46 Dimensions H×W×D mm 290×1,000×700 290×1,000×700 290×1,400×700 290×1,400×700 290×1,400×700 290×1,400×700 290×1,400×700 290×1,400×700 kg 33 33 45 45 45 45 45 45 L/s 350 : 350 350 : 350 533 : 533 533 : 533 566 : 566 566 : 566 600 : 600 600 : 600 Pa 70 (10 - 150) 70 (10 - 150) 100 (10 - 150) 100 (10 - 150) 100 (10 - 150) 100 (10 - 150) 100 (10 - 150) 100 (10 - 150) Net weight Air volume Cooling : Heating External static pressure Sound pressure level (H/M/L) Cooling : Heating dB(A) 35 / 32 / 26 : 35 / 32 / 26 35 / 32 / 26 : 35 / 32 / 26 38 / 34 / 31 : 38 / 34 / 31 38 / 34 / 31 : 38 / 34 / 31 39 / 35 / 32 : 39 / 35 / 32 39 / 35 / 32 : 39 / 35 / 32 40 / 36 / 33 : 40 / 36 / 33 40 / 36 / 33 : 40 / 36 / 33 Sound power level (H/M/L) Cooling : Heating dB(A) 58 / 55 / 49 : 58 / 55 / 49 58 / 55 / 49 : 58 / 55 / 49 61 / 57 / 54 : 61 / 57 / 54 61 / 57 / 54 : 61 / 57 / 54 62 / 58 / 55 : 62 / 58 / 55 62 / 58 / 55 : 62 / 58 / 55 63 / 59 / 56 : 63 / 59 / 56 63 / 59 / 56 : 63 / 59 / 56 mm VP-25 VP-25 VP-25 VP-25 VP-25 VP-25 VP-25 VP-25 Drain piping Outdoor Unit Current Cooling : Heating A 7.40 : 7.10 | 8.40 : 8.10 8.60 : 9.50 | 8.30 : 9.20 10.60 : 11.20 | 10.30 : 10.70 3.53 : 3.70 | 3.43 : 3.58 15.90 : 15.80 | 15.30 : 15.10 5.29 : 5.26 | 5.12 : 5.05 19.30 : 19.10 | 18.60 : 18.40 6.42 : 6.35 | 8.18 : 6.15 Dimensions H×W×D mm 996 × 940 × 340 996 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 98 Net weight 30 kg 68 69 98 98 98 98 98 Air volume Cooling : Heating L/s 1,000 : 1,000 1,000 : 1,000 1,833 : 1,583 1,833 : 1,583 2,166 : 1,833 2,166 : 1,833 2,250 : 2,000 2,250 : 2,000 Sound pressure level Cooling : Heating dB(A) 48 : 50 48 : 50 52 : 52 52 : 52 53 : 53 53 : 53 54 : 55 54 : 55 Sound power level Cooling : Heating dB(A) 65 : 67 65 : 67 69 : 69 69 : 69 70 : 70 70 : 70 71 : 71 71 : 71 Piping connections Liquid / Gas m Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Pipe length min. - max. m 5 - 50 5 - 50 5 - 75 5 - 75 5 - 75 5 - 75 5 - 75 5 - 75 Elevation difference (OU located lower, OU located higher) m 15, 30 15, 30 15, 30 15, 30 15, 30 15, 30 15, 30 15, 30 Maximum chargeless length m 30 30 30 30 30 30 30 30 Refrigerant at shipping, Additional gas amount g R410A 2,000, 50 (g/m) R410A 2,350, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) Operation ranges ˚C -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 Cooling : Heating 31 Indoor Unit / 4-Way Cassette Indoor Unit 4-WAY Cassette AIR INTAKE CHAMBER PANEL (CZ-KPU21) 1 2 Provides a neat fit in the ceiling to match modern decor, and uniform cooling throughout the room, plus easy installation. ECONAVI ready 1 Air intake box CZ-BCU2 for main unit. 2 Air intake box CZ-ATU2* for Air intake plenum. ECONAVI ready NEW * When using Air intake box (CZ-ATU2), Air intake plenum (CZ-FDU2) required. Self-diagnosing Function Automatic Fan Operation Mild dry Intelligent Auto Swing Automatic Restart Function Auto Swing (Auto Flap Control) CZ-CENSC1 Built-in Drain Pump Technical focus • Compact design • Low sound levels • DC fan motor for increased efficiency • Powerful drain pump gives 850 mm lift CZ-RTC3 CZ-RTC4 High-Ceiling Installation (Up to 5 m for 10.0kW+ models) • Lightweight design • Fresh air knockout • Branch duct connection • Optional air-intake plenum CZ-FDU2 The units can be installed in rooms with high ceilings, where they provide ample floor-level heating in the winter. (See ceiling height guidelines below.) High Ceiling (Factory settings) 3.6m 3.0m New model Wide & Comfortable Airflow A proprietary design features wide-angle discharge outlets and flaps that are larger in the middle, featuring a shape that was selected based on numerical mechanics and testing of actual prototype units. Air coming out of the centre of the discharge outlets travels farther. From the sides of each outlet, where the openings are larger, airflow spreads out to reach the corners of the room. Air is discharged across a wide area from the four sides of the unit. The curves on the room temperature distribution graph expand gently out through 360° in a circle centred on the indoor unit. Temperature distribution by thermograph (cooling operation) Comfort/Quiet Ample airflow: 36 m3/min 32 100PU, 125PU, 140PU Industry’s leading in the 140PU class. Industry’s top-class 4-way discharge Capacity 5m 4.7m 4.5m 100PU-140PU high ceiling settings2 3-way discharge 2-way discharge with the optional air-blocking materials with the optional air-blocking materials Ceiling height guidelines 360° Wide *1 settings 4-way discharge 3-way discharge (optional 2-way discharge (optional Factory settings 1 High ceiling setting 1 High ceiling setting 2 60PU-71PU 3.0 3.3 3.6 3.8 4.2 100PU, 125PU, 140PU 3.6 3.9 4.5 4.7 5.0 Indoor unit 1m Simulation conditions: P140 4-way ceiling-mounted cassette type in cooling mode / Floor area of 225 m2 / Ceiling height of 3 m 60PU, 71PU Capacity air-blocking materials) air-blocking materials) *2 *1 When using the unit in a configuration other than the factory settings, it is necessary to make settings on site to increase airflow. *2 Use air-blocking materials (CZ-CFU2) to completely block two discharge outlets for 2-way airflow. 33 Indoor Unit / 4-Way Cassette Indoor Unit 4-way Cassette 13 ø1 Up to 850 mm 6 167 130 95 B 30 * Adjust the suspension bolt length so that the gap from the lower ceiling surface becomes 30 mm or more (18 mm or more from the lower surface of the body) as shown in the figure. When the suspension bolt length is long, it hits the ceiling panel and installation is not possible. 7.1kW 10.0kW S-71PU1R5A S-100PU1R5A S-100PU1R5A S-125PU1R5A S-125PU1R5A S-140PU1R5A S-140PU1R5A Outdoor Unit U-60PE1R5A U-71PE1R5A U-100PE1R5A U-100PE1R8A U-125PE1R5A U-125PE1R8A U-140PE1R5A U-140PE1R8A 12.5kW 14.0kW CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 Phase/Hz 1 phase, 50Hz 1 phase, 50Hz 1 phase, 50Hz 3 phase, 50Hz 1 phase, 50Hz 3 phase, 50Hz 1 phase, 50Hz 3 phase, 50Hz V 230V | 240V 230V | 240V 230V | 240V 400V | 415V 230V | 240V 400V | 415V 230V | 240V 400V | 415V kW 6.0 (2.5 - 8.0) 7.0 (2.0 - 8.5) 7.1 (2.5 - 8.2) 8.0 (2.0 - 9.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0) 14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0) BTU/h 20,500 (8,500 - 27,300) 23,900 (6,800 - 29,000) 24,200 (8,500 - 28,000) 27,300 (6,800 - 30,700) 34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800) 34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400) 47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400) Cooling : Heating W/W 4.05 : 3.87 3.94 : 4.00 4.20 : 4.31 4.20 : 4.31 3.60 : 4.00 3.60 : 4.00 3.25 : 3.70 3.25 : 3.70 kW 1.48 : 1.81 1.80 : 2.00 2.38 : 2.60 2.38 : 2.60 3.47 : 3.50 3.47 : 3.50 4.31 : 4.33 4.31 : 4.33 Cooling : Heating A 0.31 : 0.30 | 0.30 : 0.29 0.33 : 0.32 | 0.32 : 0.31 0.71 : 0.65 | 0.71 : 0.64 0.71 : 0.65 | 0.71 : 0.64 0.76 : 0.73 | 0.73 : 0.73 0.76 : 0.73 | 0.73 : 0.73 0.89 : 0.80 | 0.87 : 0.79 0.89 : 0.80 | 0.87 : 0.79 Indoor mm 256 × 840 × 840 256 × 840 × 840 319 × 840 × 840 319 × 840 × 840 319 × 840 × 840 319 × 840 × 840 319 × 840 × 840 319 × 840 × 840 Indoor Unit Panel mm 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 Net weight Indoor kg 24 24 27 27 27 27 27 27 Panel kg 4 4 4 4 4 4 4 4 Air volume Cooling : Heating L/s 350 : 350 366 : 366 550 : 550 550 : 550 583 : 583 583 : 583 600 : 600 600 : 600 Sound pressure level (H/M/L) Cooling : Heating dB(A) 36 / 31 / 28 : 36 / 31 / 28 37 / 31 / 28 : 37 / 31 / 28 44 / 38 / 32 : 44 / 38 / 32 44 / 38 / 32 : 44 / 38 / 32 45 / 39 / 33 : 45 / 39 / 33 45 / 39 / 33 : 45 / 39 / 33 46 / 40 / 34 : 46 / 40 / 34 46 / 40 / 34 : 46 / 40 / 34 Sound power level (H/M/L) Cooling : Heating dB(A) 53 / 48 / 45 : 53 / 48 / 45 54 / 48 / 45 : 54 / 48 / 45 62 / 55 / 49 : 62 / 55 / 49 62 / 55 / 49 : 62 / 55 / 49 63 / 56 / 50 : 63 / 56 / 50 63 / 56 / 50 : 63 / 56 / 50 64 / 57 / 51 : 64 / 57 / 51 64 / 57 / 51 : 64 / 57 / 51 3 3 3 3 3 3 3 3 mm VP-25 VP-25 VP-25 VP-25 VP-25 VP-25 VP-25 VP-25 A 6.90 : 8.20 | 6.70 : 7.95 8.10 : 9.00 | 7.90 : 8.70 10.3 : 11.4 | 9.90 : 11.0 3.50 : 3.85 | 3.40 : 3.75 15.3 : 15.4 | 14.8 : 14.9 5.15 : 5.20 | 5.00 : 5.05 19.0 : 19.2 | 18.4 : 18.6 6.45 : 6.50 | 6.20 : 6.25 mm 996 × 940 × 340 996 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 kg 68 69 98 98 98 98 98 98 Number of fan speed 160 118 18 2 6.0kW Drain pipe size 2 Dimensions: mm Cooling : Heating H×W×D 7 Drain up Air intake duct connection hole (ø100) EER : COP Dimensions 9 1 80 Total power input Current 160 2 S-60PU1R5A Cooling capacity Heating capacity 82 2 Indoor Unit Panel 50 515 le 4 -ø3 Burring ho The drain height can be increased by approximately 350 mm over the conventional value by using a high-lift drain pump, and long horizontal piping is possible. 271 950 514 Less than 670 115 Drain Pump of about 850 mm from the ceiling surface 115 Air discharge duct connection hole (ø150) Up to 300 mm X view 4 160 7 Less than 300 Less than 850 ø3 hole 4 Burring 256 mm 480 7 A 180 B 145 80 A Drain Height of Approx. 850 mm from the Ceiling Surface Less than 35 7 62 ø1 Capacity 2 95 Less than 35 Only 3 100PU-140PU 319 187 840 167 Protrusion of 33.5 mm A lightweight unit at 24 kg, the unit is also very slim with a height of only 256 mm, making installation possible even in narrow ceilings. * For 6.0kW/7.1kW Power source 345 5 840 480 60PU-71PU 256 124 130 8 *1: Air inlet kit is necessary. Filter size: 520 x 520 x 16 Lighter and Slimmer, Easier Installation Model Name 786 (Suspension bolt pitch) 745 (Suspension bolt pitch) 860~910 (Ceiling opening dimension) The square panel integrates seamlessly with the ceiling. Discharge outlets close when the unit is stopped. A B (411) One of the industry’s thinnest panels X 860~910 (Ceiling opening dimension) Air intake grill Air discharge outlet Refrigerant piping (liquid pipes) : ø9.52 (flared) Refrigerant piping (gas pipes) : ø15.88 (flared) Drain outlet VP25(outer ø32) Power supply port Discharge duct (ø150) Suspension bolt hole (4-12x30 slot) Fresh air intake duct connection port (ø100)*1 50 Low-Profile 33.5 mm Panel 1 2 3 4 5 6 7 8 9 42 121 33.5 The flap can be removed easily for cleaning. Dimensions Suction grill able to make 90 degree turns. 950 It is easy to remove the washable flaps by hand. 421 Easy Maintenance and Cleaning Optional Controller ECONAVI sensor CZ-CENSC1 NEW Timer remote controller CZ-RTC4 Deluxe Wired remote controller CZ-RTC3 Wireless remote controller CZ-RWSU2N Outdoor Unit Current Dimensions Cooling : Heating H×W×D Net weight Air volume Cooling : Heating L/s 1,000 : 1,000 1,000 : 1,000 1,833 : 1,583 1,833 : 1,583 2,166 : 1,833 2,166 : 1,833 2,250 : 2,000 2,250 : 2,000 Sound pressure level (Silent mode) Cooling : Heating dB(A) 48 (46) : 50 (48) 48 (46) : 50 (48) 52 (50) : 52 (50) 52 (50) : 52 (50) 53 (51) : 53 (51) 53 (51) : 53 (51) 54 (52) : 55 (53) 54 (52) : 55 (53) Sound power level (Silent mode) Cooling : Heating dB(A) 65 (63) : 67 (65) 65 (63) : 67 (65) 69 (67) : 69 (67) 69 (67) : 69 (67) 70 (68) : 70 (68) 70 (68) : 70 (68) 71 (69) : 71 (69) 71 (69) : 71 (69) m Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 min. - max. m 5 - 50 5 - 50 5 - 75 5 - 75 5 - 75 5 - 75 5 - 75 5 - 75 Piping connections Pipe length 34 Elevation difference (OU located lower, OU located higher) m 15, 30 15, 30 15, 30 15, 30 15, 30 15, 30 15, 30 15, 30 Maximum chargeless length m 30 30 30 30 30 30 30 30 Refrigerant at shipping, Additional gas amount g R410A 2,000, 50 (g/m) R410A 2,350, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) Operation ranges ˚C -15 - 46 : -20 - 24 -15 - 46 : -20 - 24 -15 - 46 : -20 - 24 -15 - 46 : -20 - 24 -15 - 46 : -20 - 24 -15 - 46 : -20 - 24 -15 - 46 : -20 - 24 -15 - 46 : -20 - 24 Cooling : Heating Simplified remote controller CZ-RE2C2 35 Indoor Unit / Under Ceiling Indoor Unit Under Ceiling Providing outstanding energy-saving performance, comfort and long-distance air flow distribution, these units are perfect for retail stores and schools. ECONAVI ready S-60PT2R5A S-71PT2R5A S-100PT2R5A S-125PT2R5A S-140PT2R5A ECONAVI ready CZ-CENSC1 Compact Looking, Stylish, One-Motion Design Comfortable, Long-Distance Air Flow Distribution With its streamlined, one-motion form, the unit looks thin and compact when installed for a neat appearance in any room. When not operating, the louver closes to provide an elegant look while also keeping the unit clean. The shape of the outlet has been optimised to provide long-distance air flow distribution. Even in long rooms, air flow reaches every corner for exceptionally comfortable air conditioning. Energy-Saving Technology Delivering Top-Class Efficiency 4.3m* Top Class Energy Saving Air flow distance 13m* * Results are based on specific testing conditions Large Diagonal Air Flow Fan High Ceiling Setting DC motor 36 CZ-RTC4 Ceiling height Optimisation of the shape of the casing and fan assures bigger air flow and higher efficiency. Energy-saving performance is top class in the industry. New DC fan motor CZ-RTC3 NEW Air flow distance *Setting by remote control 100 125 140 4.3m 12m 13m 13m Fan diameter f 147.5 37 Indoor Unit / Under Ceiling Indoor Unit Under Ceiling Dimensions 73 123 7 Indoor Units: S-60PT2R5A S-71PT2R5A 1226 (Suspension bolt pitch) Tubing hole position on wall surface (Figure shows view from front) Capacity Air discharge 114 Over 250 Over 250 1590 Service space Tubing hole position on wall surface (Figure shows view from front) 216 216 2 96 90 (Left drain position) (Closed with rubber stopper at time of shipment.) 12.0kW 3 4 6.0kW 7.1kW 10.0kW S-60PT2R5A S-71PT2R5A S-100PT2R5A S-100PT2R5A S-125PT2R5A S-125PT2R5A S-140PT2R5A S-140PT2R5A Outdoor Unit U-60PE1R5A U-71PE1R5A U-100PE1R5A U-100PE1R8A U-125PE1R5A U-125PE1R8A U-140PE1R5A U-140PE1R8A 3-Phase/ 50Hz Cooling capacity : Heating capacity 14.0kW Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 3-Phase/ 50Hz 1 Phase/ 50Hz 3-Phase/ 50Hz 1 Phase/ 50Hz V 230V | 240V 230V | 240V 230V | 240V 400V | 415V 230V | 240V 400V | 415V 230V | 240V 400V | 415V kW 6.0 (2.5 - 7.1) 7.0 (2.0 - 8.0) 7.1 (2.5 - 8.0) 8.0 (2.0 - 9.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 14.0 (3.3 - 15.0) 16.0 (4.1 - 18.0) 14.0 (3.3 - 15.0) 16.0 (4.1 - 18.0) BTU/h 20,500 (8,500 - 24,200) 23,900 (6,800 - 27,300) 24,200 (8,500 - 27,300) 27,300 (6,800 - 30,700) 34,100 (11,300 - 42,700) 34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800) 38,200 (14,000 - 47,800) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 47,800 (11,300 - 51,200) 54,600 (14,000 - 61,400) 47,800 (11,300 - 51,200) 54,600 (14,000 - 61,400) W/W 4.03 : 4.02 3.68 : 4.15 3.95 : 4.31 3.95 : 4.31 3.35 : 3.99 3.35 : 3.99 3.01 : 3.67 3.01 : 3.67 Cooling : Heating kW 1.49 : 1.74 1.93 : 1.93 2.53 : 2.60 2.53 : 2.60 3.73 : 3.51 3.73 : 3.51 4.65 : 4.36 4.65 : 4.36 Current Cooling : Heating A 0.41 : 0.41 | 0.40 : 0.40 0.44 : 0.44 | 0.43 : 0.43 0.67 : 0.67 | 0.65 : 0.65 0.67 : 0.67 | 0.65 : 0.65 0.86 : 0.86 | 0.83 : 0.83 0.86 : 0.86 | 0.83 : 0.83 0.91 : 0.91 | 0.88 : 0.88 0.91 : 0.91 | 0.88 : 0.88 Dimensions H×W×D mm 235×1,275×690 235×1,275×690 235×1,590×690 235×1,590×690 235×1,590×690 235×1,590×690 235×1,590×690 235×1,590×690 kg 33 33 40 40 40 40 40 40 L/s 333 : 333 350 : 350 500 : 500 500 : 500 566 : 566 566 : 566 583 : 583 583 : 583 Pa - - - - - - - - EER : COP Total power input Indoor Unit Net weight Air volume Cooling : Heating External static pressure Sound pressure level (H/M/L) Cooling : Heating dB(A) 38 / 34 / 30 : 38 / 34 / 30 39 / 35 / 31 : 39 / 35 / 31 42 / 37 / 35 : 42 / 37 / 35 42 / 37 / 35 : 42 / 37 / 35 Sound power level (H/M/L) Cooling : Heating dB(A) 56 / 52 / 48 : 56 / 52 / 48 57 / 53 / 49 : 57 / 53 / 49 60 / 55 / 53 : 60 / 55 / 53 60 / 55 / 53 : 60 / 55 / 53 64 / 58 / 54 : 64 / 58 / 54 64 / 58 / 54 : 64 / 58 / 54 65 / 59 / 55 : 65 / 59 / 55 65 / 59 / 55 : 65 / 59 / 55 3 3 3 3 3 3 3 3 mm VP-20 VP-20 VP-20 VP-20 VP-20 VP-20 VP-20 VP-20 Number of fan speed Drain pipe size 186 Service space Indoor Unit Power source 80 9 86 (Gas tubing) 70 (Liquid tubing) 90 (Right drain position) 3 4 1 8 131 193 235 Air intake 6 216 4 5 Service space 2 690 176 186 Minimum 50cm Service space 80 Approx. 2° 131 193 235 Over 250 1275 90 (Left drain position) (Closed with rubber stopper at time of shipment.) S-100PT2R5A S-125PT2R5A S-140PT2R5A 1584 176 Minimum 50cm Over 250 9 Model Name 1 8 216 15 690 4 15 Approx. 2° Air intake Air discharge Indoor Units: 1541 (Suspension bolt pitch) 1269 5 61 73 61 265 190 (Suspension bolt pitch) 123 7 114 Drain port VP20 (inside diameter ø26mm, drain hose supplied) Left drain position Refrigerant liquid tubing (ø9.52mm, flare connection) Refrigerant gas tubing (ø15.88mm, flare connection) Left side drain hose outlet port (cutout) Tubing hole on wall surface (ø100mm) Upper side tubing port Right side drain hose outlet port (cutout) Wireless remote controller receiver installation location 265 190 (Suspension bolt pitch) 1 2 3 4 5 6 7 8 9 6 96 86 (Gas tubing) 70 (Liquid tubing) 90 (Right drain position) Optional Controller ECONAVI sensor CZ-CENSC1 NEW Deluxe Wired remote controller CZ-RTC3 46 / 40 / 36 : 46 / 40 / 36 46 / 40 / 36 : 46 / 40 / 36 47 / 41 / 37 : 47 / 41 / 37 47 / 41 / 37 : 47 / 41 / 37 Timer remote controller CZ-RTC4 Wireless remote controller CZ-RWST3N Outdoor Unit Current Cooling : Heating A 6.90 : 7.80 | 6.70 : 7.60 8.70 : 8.60 | 8.40 : 8.30 11.1 : 11.4 | 10.6 : 11.0 3.75 : 3.85 | 3.65 : 3.75 16.4 : 15.4 | 15.8 : 14.9 5.55 : 5.20 | 5.35 : 5.05 20.5 : 19.2 | 19.8 : 18.5 6.95 : 6.50 | 6.70 : 6.25 Dimensions H×W×D mm 996 × 940 × 340 996 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 98 Net weight 38 kg 68 69 98 98 98 98 98 Air volume Cooling : Heating L/s 1,000: 1,000 1,000: 1,000 1,833: 1,583 1,833: 1,583 2,166: 1,833 2,166: 1,833 2,250: 2,000 2,250: 2,000 Sound pressure level Cooling : Heating dB(A) 48 : 50 48 : 50 52 : 52 52 : 52 53 : 53 53 : 53 54 : 55 54 : 55 Sound power level Cooling : Heating dB(A) 65 : 67 65 : 67 69 : 69 69 : 69 70 : 70 70 : 70 71 : 71 71 : 71 Piping connections Liquid/Gas m Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Pipe length min. - max. m 5 - 50 5 - 50 5 - 75 5 - 75 5 - 75 5 - 75 5 - 75 5 - 75 Elevation difference (OU located lower, OU located higher) m 15, 30 15, 30 15, 30 15, 30 15, 30 15, 30 15, 30 15, 30 Maximum chargeless length m 30 30 30 30 30 30 30 30 Refrigerant at shipping, Additional gas amount g R410A 2,000, 50 (g/m) R410A 2,350, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) Operation ranges ˚C -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 Cooling : Heating Simplified remote controller CZ-RE2C2 39 Controllers Controllers ECONAVI Sensor [CZ-CENSC1] Utilises ECONAVI Sensor and Control Program technologies to detect where energy is normally wasted and selfadjusts cooling power to reduce energy waste. A wide variety of control options to meet the requirements of different applications. • Activity detection • Absence detection OPERATION SYSTEM Requirements INDIVIDUAL CONTROL SYSTEMS High-spec operation Normal operation TIMER OPERATION Operation from anywhere Quick and easy operation in the room Daily and weekly program CENTRALISED CONTROL SYSTEMS Operation with various function Only ON/OFF operation from from centre station centre station Simplified load distribution ratio (LDR) for each tenant Touch screen panel NEW BMS System PC Base P-AIMS Basic Software Connection with 3rd Party Controller Seri-Para I/O unit for outdoor unit External appearance CZ-CAPDC2 Deluxe Wired Remote Controller CZ-CSWKC2 Timer Remote Controller (Wired) Wireless Remote Controller CZ-RTC3 CZ-RTC4 CZ-RWSU2N C-RWSK2 + CZ-RWST3N CZ-RWSC3 CZ-RE2C2 CZ-ESWC2 ECONAVI on/off control l l l l l — l — Number of indoor units which can be controlled 1 group, 8 units 1 group, 8 units 1 group, 8 units 1 group, 8 units Type, model name Built-in thermostat Use limitations Function ON/OFF Mode setting Fan speed setting Temperature setting Air flow direction Permit/Prohibit switching Weekly program ·U p to 2 controllers can · Up to 2 controllers can · Up to 2 controllers can be connected per be connected per be connected per group (When using group. (When using group. ECONAVI sensor, only ECONAVI sensor, only one remote controller one remote controller is is possible to connect possible to connect at at indoor unit) indoor unit) l l l l l l l l l l l l — l l l l l l — — Simplified Remote Controller Schedule Timer System Controller ON/OFF Controller Intelligent Controller CZ-64ESMC2 CZ-ANC2 CZ-256ESMC2 (CZ-CFUNC2) — — — — — — — — 64 groups, max. 64 units 64 groups, max. 64 units 16 groups, max. 64 units 64 units x 4 links, max. 256 units Interface adaptor ·U p to 2 controllers can be connected per group. l l l l l — — ·R equired power supply from the system controller ·W hen there is no system controller, connection is possible to the T10 terminal of an indoor unit. — — — — — — l ·U p to 10 controllers, can be · U p to 8 controllers (4 main ·A communication adaptor connected to one system. units + 4 sub units) (CZ-CFUNC2) must be ·M ain unit/sub unit (1 main can be connected to one installed for three or more unit + 1 sub unit) connection system. links. is possible. ·U se without remote controller ·U se without remote controller is impossible. is possible. l l l l l¹ l — l — — — — l — l l l l l¹ l l Optional software CZ-CAPC2 CZ-CSWAC2 for Load distribution CZ-CSWWC2 for Web application CZ-CSWGC2 for Object layout display CZ-CSWBC2 for BACnet software interface *PC required (field supply) Web Interface Systems Seri-Para I/O unit for each indoor unit CZ-CAPBC2 Communication Adaptor CZ-CFUNC2 LonWorks Interface CZ-CWEBC2 *PC required (field supply) CZ-CLNC2 1. Setting is not possible when a remote control unit is present. (Use the remote controller for setting.) All specifications subject to change without notice. 40 41 Controllers Individual Control Systems Deluxe wired remote controller (CZ-RTC3) Control contents Part name, model No. Quantity Standard Control • Control of the various operations of the indoor unit by wired or wireless remote controller. • Cooling or heating mode of the outdoor unit is decided by the first priority of the remote controller. • Switching between remote controller sensor and body sensor is possible. Timer remote controller CZ-RTC4 / CZ-RTC3 Simplified remote controller CZ-RE2C2 Wireless remote controller CZ-RWSU2N / CZ-RWST3N / CZ-RWSK2 + CZ-RWSC3 1 unit each (1) Group control • Batch remote control on all indoor units. • Operation of all indoor cells in the same mode. • Up to 8 units can be connected. • The sensor is the body sensor, and thermostat ON/OFF setting in regard to the temperature set by the remote controller is possible for each indoor unit. Timer remote controller CZ-RTC4 / CZ-RTC3 Simplified remote controller CZ-RE2C2 Wireless remote controller CZ-RWSU2N / CZ-RWST3N / CZ-RWSK2 + CZ-RWSC3 As required (2) Main/sub remote control • Max 2 remote controllers per indoor unit. (Main remote controller can be connected) • The button pressed last has priority. • Timer setting is possible even with the sub remote controller. When using ECONAVI sensor, only one remote controller is possible to connect at indoor unit. Main or sub Timer remote controller CZ-RTC4 / CZ-RTC3 Simplified remote controller CZ-RE2C2 Wireless remote controller CZ-RWSU2N / CZ-RWST3N / CZ-RWSK2 + CZ-RWSC3 Basic Operation Dimensions H 120 x W 120 x D 16 mm As required • Individual Louver Control (Lock individual flap for 4-way cassette) • ON/ OFF timer • Weekly Timer • Filter information* • Outing function • Quiet operation mode* • Power consumption monitor* • Energy saving* • Initial settings • Ventilation Energy Saving Maintenance Function • ECONAVI on/ off* • Temperature Auto Return • Temperature Setting Range • Auto Shutoff • Schedule peak cut • Repeat off timer • Outdoor unit error data • Service Contact address • RC setting mode • Test Run • Sensor Information* • Service check • Simple/ Detailed Settings • Auto address * Subject to the connected model SYSTEM EXAMPLE Timer remote controller (CZ-RTC4) NEW Weekly Programme Function • A maximum of 6 settings/day and 42 settings/week can be programmed. Outing Function • This function can prevent the room temperature from dropping or rising when the occupants are out for a long time. Sleeping Function Remote controller Main Sub Main Sub Dimensions H 120 x W 120 x D 20 mm Basic remote controller ON/OFF Standard control (2) Main/sub remote control (1) Group control • Operation mode changeover (Cooling, Heating, Dry, Auto, Fan). • Temperature setting (Cooling/Dry: 18-30 deg Heating: 16-30 deg). • Fan speed setting H/ M/ L and Auto. • Air flow direction adjustment. • ECONAVI on/ off* • This function controls the room temperature for comfortable sleeping. Max. 8 indoor units can be controlled from one remote controller Remote control by main remote controller and sub controller is possible Max. 2 remote controllers (main remote controller and sub controller) can be installed for one indoor unit. * Depending on the model, some menus cannot be used. Time Function 24 hours real time clock • Day of the week indicator. 42 43 Controllers Wireless remote controller Remote control by main remote controller and sub controller is possible T10 Terminal for External Control (Digital Connection) • Max. 2 remote controllers (main remote controller and sub controller) can be installed for one indoor unit. For 4-Way cassette type CZ-RWSU2N When CZ-RWSC3 is used, wireless control becomes possible for all indoor units • When a separate receiver is set up in a different room, control from that room also becomes possible. • Automatic operation by means of the emergency operation button is possible even when the remote controller has been lost or the batteries have been exhausted. Connecting an indoor unit to an external device is easy. The T10 Terminal featured in the electronic circuit board of all indoor units enables digital connection to external devices. In addition, there are other functions such as temperature setting, operation switching, wind direction/fan speed setting, etc For all Ducted types CZ-RWSK2 + CZ-RWSC3 Ventilation independent operation is possible When commercial ventilation fans or heat-exchange ventilation fans have been installed, they can be operated with this remote control (interlocked operation with the indoor unit or independent ventilation ON/OFF). 1. T10 Terminal Specification (T10:CN061 at indoor unit PCB) 1 • ControlCOM items: 1. Start/stop input 2 3 2. Remote controller prohibit input 4 3. Start signal output +12V COM 5 T10 4. Alarm signal output For under ceiling type CZ-RWST3N (yellow) A remote controller with simple functions and basic operation • Suitable for open rooms or hotels where detailed functions are not required. • ON/OFF, operation mode switching, temperature setting, wind velocity switching, wind direction setting, alarm display, and remote controller self-diagnosis can be performed. • Batch group control for up to 8 indoor units. • Remote control by main remote controller and sub controller is possible with a simplified remote controller or a wired remote controller (up to two units). Dimensions H 120 x W 70 x D 17 mm 3 4 T10 (yellow) 1-2 (pulse input) ON OFF COM 5 Condition +12 4-5 (output) Unit condition 1 COM 2 6 300msec. or more Simplified remote controller (CZ-RE2C2) • Example of wiring ON NOTE: The wire length from indoor unit to the Relay must be within 2.0m. Pulse signal changeable to static with JP cutting. (Refer to JP001) 6 300msec. or more 1. 1-2 (Pulse input): Unit ON/OFF condition switching with a pulse signal. (1 1-2pulse (pulse input) signal: shortage status more than 300msec.or more) 2. 2-3 (Static input): Open/ Operation with Remote is permitted.(Normal condition) Close/ Remote controller is prohibited. +12 the unit ON. / No output at OFF. 3. 4-5 (Static output): 12V output during 4-5 (output) 4. 5-6 (Static output): 12V output when some errors occur / No output at normal. Unit condition ON OFF ON 2. Usage Example Forced OFF control Operation ON/OFF signal output • Condition • Condition 1-2 (Static input): Close/ Operation with Remote is permitted. (Normal condition) Open/ Unit is forcibly OFF and Remote controller operation is prohibited. 4-5 (Static output): 12V output during the unit ON / No output at OFF • Example of wiring • Example of wiring Relay (Field supply) T10 (YEL) Relay (Field supply) T10 (YEL) Indoor unit control PCB Central control The contact in the figure is a state where the card is pulled out. POWER External contact (Card switch box, etc.: field supply) NOTE: The wire length from indoor unit to the Relay must be within 2.0m 44 +12V Indoor unit control PCB 2m NOTE: The wire length from indoor unit to the Relay must be within 2.0m Pulse signal changeable to static with JP cutting. (Refer to JP001) 45 Controllers Remote Controller External Dimensions TIMER REMOTE CONTROLLER (CZ-RTC4) COMMUNICATION ADAPTOR (CZ-CFUNC2) 256 120 120 80 38 290 270 INTELLIGENT CONTROLLER (CZ-256ESMC2) 180 DELUXE WIRED REMOTE CONTROLLER (CZ-RTC3) 38 167 R 2.5 79 120 16 24.75 20 120 8 R5 ø22.2 (mm) SEPARATE RECEIVER FOR WIRELESS REMOTE CONTROLLER (CZ-RWSC3) ON/OFF CONTROLLER (CZ-ANC2) SERI-PARA I/O UNIT FOR EACH INDOOR UNIT (CZ-CAPBC2) 116 20 WIRELESS REMOTE CONTROLLER 6 160 148 (6) 14 69 160 148 121 115 120 6 70 (6) Unit: mm SYSTEM CONTROLLER (CZ-64ESMC2) 66.8 17 70 LONWORKS INTERFACE (CZ-CLNC2) 116 10 SERI-PARA I /O UNIT FOR OUTDOOR UNIT (CZ-CAPDC2) 4.4 16.7 SIMPLIFIED REMOTE CONTROLLER (CZ-RE2C2) 122 9.4 160 148 (6) 21 69 4 - Ø 5 hole 115 121 33.4 160 148 5.4 13 4.4 8 33.5 16.6 6 6 116.8 83.5 120 9.4 (6) Potbellied hole (4 locations) 3 - Ø 30 hole 121 Magnified view ECONAVI SENSOR (CZ-CENSC1) Detail of the potbellied hole REMOTE SENSOR (CZ-CSRC3) 17 120 70 46 47