Switch-mode power supplies connectPower PROeco PROeco power supplies with basic functionality and a high level of reliability •Single- and three-phase switched-mode power supply units •Slim design •Large temperature range from –25 °C to 70 °C •The output voltage can be precisely adjusted via the potentiometer on the front •Remote monitoring via integrated status relay •Three-coloured LED indicators for simple error detection •Advanced visual warning at 90 % rated output current •International approvals A % Derating curves Technical data ≤ 480 Watt 120 Ioutput (% IN) 100 80 60 40 20 0 –25 0 20 30 40 50 Ambient temperature (°C) 60 70 Ioutput (% IN) 100 80 60 40 20 0 –25 A.4 General technical data Ambient temp. operating / storage temperature Max. perm. air humidity (operation) Degree of protection Class of protection Pollution degree Insulation voltage input/output MTBF Parallel connection option Housing version Mounting position, installation notice Short-circuit protection Overload protection Overtemperature protection EMC / shock / vibration Noise emission acc. to EN55022 Noise immunity tests acc. to 960 Watt 120 0 \ 20 30 40 50 Ambient temperature (°C) 60 70 Limiting of mains voltage harmonic currents Resistance against vibration and shock Electrical safety (applied standards) Electrical equipment of machines Safety transformers for switched-mode power units Machinery with electronic equipment Safety extra-low voltage Protective separation / protection against electrical shock Protection against dangerous shock currents –25 °C…+70 °C / –40 °C…+85 °C 5 %…95 % RH IP 20 I, with PE connection 2 3 kV E/A / 2 kV E/earth / 0.5 kV A/earth > 500.000 h acc. to IEC 1709 (SN29500) yes, max. 5 without diode module metal, corrosion resistant horizontal on mounting rail TS 35, 50 mm spacing top and bottom for free air circulation Yes, automatic restart Yes, IU characteristic curve Yes, automatic restart Class B EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields), EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN61000-4-6 (conducted), EN61000-4-11 (Dips) Acc. to EN61000-3-2 1 g acc. to EN50178, shock: 15 g in all directions Acc. to EN60204 Acc. to EN61558-2-17 Acc. to EN50178 / VDE0160 SELV acc. to EN60950-1, PELV acc. to EN60204-1 VDE0100-410 / acc. to DIN57100-410 Acc. to VDE0106-101 1460790000 – 2014/2015 PRO ECO 72W 24V 3A PROeco Switch-mode power supplies connectPower PROeco PRO ECO 120W 24V 5A A L (+) N (–) AC PE DC + L (+) – – 13 14 N (–) Pay attention to polarity of DC connection AC PE + + – – 13 14 DC Pay attention to polarity of DC connection Technical data Input Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal) / inrush current Recommended back-up fuse Output Rated output voltage Output voltage Ramp-up time / residual ripple, switching peaks Rated output current @ Urated Continuous output current @ 24 V DC Power boost @ 24 V DC, 60 °C Capacitive load Protection against reverse voltages from the load Protection against internal surge voltage Signalling DC OK Alarm Error Voltage monitoring / no-voltage contact / contact load On/Off relay General data Efficiency Power loss @ idling / nominal load Earth discharge current Power factor (approx.) Mains buffering @ Irated Parallel connection option Height x width x depth / weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil Min./max. tightening torque range Stripping length Note Ordering data Note 1460790000 – 2014/2015 mm² mm² min/max Nm mm 100 … 240 V AC 85 … 264 V AC (Derating @ 100 V AC) 47 … 63 Hz 80 … 370 DC (Derating @ 120 V DC) 0.55 A @ 230 V AC / 1.04 A @ 110 V AC 0.22 A @ 370 V DC / 0.68 A @ 120 V DC Yes / max. 40 2 A / DI, Safety fuse 6 A, Char. B, Circuit breaker 2...4 A, Char. C, Circuit breaker 100 … 240 V AC 85 … 264 V AC (Derating @ 100 V AC) 47 … 63 Hz 80 … 370 DC (Derating @ 120 V DC) 1.26 A @ 230 V AC / 2.24 A @ 110 V AC 0.39 A @ 370 V DC / 1.16 A @ 120 V DC Yes / max. 40 4 A / DI, Safety fuse 6 A, Char. B, Circuit breaker 3...5 A, Char. C, Circuit breaker 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 3 A up to 55 °C 3 A @ 55 °C, 2.25 A @ 70 °C 3.6 A for 1 min, ED = 5 % Unrestricted 30…35 V DC 35 V DC 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 5 A up to 55 °C 5 A @ 55 °C, 3.75 A @ 70 °C 6 A for 1 min, ED = 5 % Unrestricted 30…35 V DC 35 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC > 87 % @ 230 V AC & 3 A 4 W / 9.5 W < 1 mA > 0.42 @ 230 V AC / > 0.45 @ 115 V AC > 100 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 5 125 / 34 / 100 mm / 0.5 kg > 87 % @ 230 V AC & 5 A 4 W / 15 W < 1 mA > 0.47 @ 230 V AC / > 0.56 @ 115 V AC > 80 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 5 125 / 40 / 100 mm / 0.6 kg CE, TÜV (EN/IEC 60950-1), cULus (Pending) Input Output Screw connection Screw connection 3 for L/N/PE 5 (13,14,+, - -) 0.5/6 0.5/6 0.5/2.5 0.5/2.5 26/12 26/12 0.5/0.6 0.5/0.6 6 6 CE, TÜV (EN/IEC 60950-1), cULus (Pending) Input Output Screw connection Screw connection 3 for L/N/PE 6 (13,14,+,+, - -) 0.5/6 0.5/6 0.5/2.5 0.5/2.5 26/12 26/12 0.5/0.6 0.5/0.6 6 6 Type PRO ECO 72W 24V 3A Type PRO ECO 120W 24V 5A Qty. 1 Order No. 1469470000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. Qty. 1 Order No. 1469480000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. A.5 Switch-mode power supplies connectPower PROeco PRO ECO 240W 24V 10A PROeco PRO ECO 480W 24V 20A A L (+) N (–) AC PE + + – – 13 14 DC Pay attention to polarity of DC connection L (+) N (–) AC PE + + – – – 13 14 DC Pay attention to polarity of DC connection Technical data Input Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal) / inrush current Recommended back-up fuse Output Rated output voltage Output voltage Ramp-up time / residual ripple, switching peaks Rated output current @ Urated Continuous output current @ 24 V DC Power boost @ 24 V DC, 60 °C Capacitive load Protection against reverse voltages from the load Protection against internal surge voltage Signalling DC OK Alarm Error Voltage monitoring / no-voltage contact / contact load On/Off relay General data Efficiency Power loss @ idling / nominal load Earth discharge current Power factor (approx.) Mains buffering @ Irated Parallel connection option Height x width x depth / weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil Min./max. tightening torque range Stripping length Note Ordering data Note A.6 mm² mm² min/max Nm mm 100 … 240 V AC 85 … 264 V AC (Derating @ 100 V AC) 47 … 63 Hz 80 … 370 DC (Derating @ 120 V DC) 1.23 A @ 230 V AC / 2.47 A @ 110 V AC 1.18 A @ 370 V DC / 2.4 A @ 120 V DC Yes / max. 15 A 4 A / DI, Safety fuse 10 A, Char. B, Circuit breaker 3...4 A, Char. C, Circuit breaker 100 … 240 V AC 85 … 264 V AC (Derating @ 100 V AC) 47 … 63 Hz 80 … 370 DC (Derating @ 120 V DC) 2.37 A @ 230 V AC / 5.2 A @ 110 V AC 1.55 A @ 370 V DC / 4.65 A @ 120 V DC Yes / max. 3 A 6 A / DI, Safety fuse 16 A, Char. B, Circuit breaker 6…8 A, Char. C, Circuit breaker 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 10 A up to 55 °C 10 A @ 55 °C, 7.5 A @ 70 °C 12 A for 1 min, ED = 5 % Unrestricted 30…35 V DC 35 V DC 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 20 A up to 55 °C 20 A @ 55 °C, 15 A @ 70 °C 24 A for 1 min, ED = 5 % Unrestricted 30…35 V DC 35 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC > 90 % @ 230 V AC & 10 A 3 W / 24 W < 1 mA > 0.93 @ 230 V AC / > 0.99 @ 115 V AC > 20 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 5 125 / 60 / 100 mm / 1 kg > 91 % @ 230 V AC & 20 A 5 W / 43 W < 1 mA > 0.97 @ 230 V AC / > 0.99 @ 115 V AC > 20 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 3 125 / 100 / 120 mm / 1.6 kg CE, TÜV (EN/IEC 60950-1), cULus (Pending) Input Output Screw connection Screw connection 3 for L/N/PE 6 (13,14,+,+, - -) 0.5/6 0.5/6 0.5/2.5 0.5/2.5 26/12 26/12 0.5/0.6 0.5/0..6 6 6 CE, TÜV (EN/IEC 60950-1), cULus (Pending) Input Output Screw connection Screw connection 3 for L/N/PE 7 (13,14,+,+, - ,-,-) 0.5/6 0.18/6 0.5/2.5 0.5/2.5 26/12 26/10 0.5/0.6 0.5/0.6 6 7 Type PRO ECO 240W 24V 10A Type PRO ECO 480W 24V 20A Qty. 1 Order No. 1469490000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. Qty. 1 Order No. 1469510000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. 1460790000 – 2014/2015 Switch-mode power supplies connectPower PROeco PRO ECO 960W 24V 40A PROeco A L (+) N (–) AC PE + + – – – 13 14 DC Pay attention to polarity of DC connection Technical data Input Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal) / inrush current Recommended back-up fuse Output Rated output voltage Output voltage Ramp-up time / residual ripple, switching peaks Rated output current @ Urated Continuous output current @ 24 V DC Power boost @ 24 V DC, 60 °C Capacitive load Protection against reverse voltages from the load Protection against internal surge voltage Signalling DC OK Alarm Error Voltage monitoring / no-voltage contact / contact load On/Off relay General data Efficiency Power loss @ idling / nominal load Earth discharge current Power factor (approx.) Mains buffering @ Irated Parallel connection option Height x width x depth / weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil Min./max. tightening torque range Stripping length Note Ordering data Note 1460790000 – 2014/2015 100 … 240 V AC 85 … 264 V AC (Derating @ 100 V AC) 47 … 63 Hz 80 … 370 DC (Derating @ 120 V DC) 4.6 A @ 230 V AC / 9.9 A @ 110 V AC 2.9 A @ 370 V DC / 9 A @ 120 V DC Yes / max. 3 A 16 A / DI, Safety fuse 20 A, Char. B, Circuit breaker 16 A, Char. C, Circuit breaker 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 40 A up to 50 °C 40 A @ 50 °C, 24 A @ 70 °C 48 A for 1 min, ED = 5 % Unrestricted 30…35 V DC 35 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC > 93 % @ 230 V AC & 40 A 6 W / 76 W < 1 mA > 0.97 @ 230 V AC / > 0.99 @ 115 V AC > 20 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 3 125 / 160 / 120 mm / 2.9 kg mm² mm² min/max Nm mm CE, TÜV (EN/IEC 60950-1), cULus (Pending) Input Output Screw connection Screw connection 3 for L/N/PE 7 (13,14,+,+,+, - -) 0.18/6 0.5/16 0.5/2.5 2.5/10 26/10 22/8 0.5/0.6 1.2/1.5 7 12 Type PRO ECO 960W 24V 40A Qty. 1 Order No. 1469520000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. A.7 Switch-mode power supplies connectPower PROeco PRO ECO3 120W 24V 5A PROeco PRO ECO3 240W 24V 10A A L1 (+) L2 (–) AC L3 PE + + – – 13 14 DC Pay attention to polarity of DC connection L1 (+) L2 (–) AC L3 PE + + – – 13 14 DC Pay attention to polarity of DC connection Technical data Input Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal) / inrush current Recommended back-up fuse Output Rated output voltage Output voltage Ramp-up time / residual ripple, switching peaks Rated output current @ Urated Continuous output current @ 24 V DC Power boost @ 24 V DC, 60 °C Capacitive load Protection against reverse voltages from the load Protection against internal surge voltage Signalling DC OK Alarm Error Voltage monitoring / no-voltage contact / contact load On/Off relay General data Efficiency Power loss @ idling / nominal load Earth discharge current Power factor (approx.) Mains buffering @ Irated Parallel connection option Height x width x depth / weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil Min./max. tightening torque range Stripping length Note Ordering data Note A.8 mm² mm² min/max Nm mm 3 x 400...3 x 500 V AC (Wide-range input) 3 x 340...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC in accordance with UL 508) 0.3 A @ 3 x 500 V AC / 0.4 A @ 3 x 400 V AC 0.2 A @ 800 V DC / 0.4 A @ 450 V DC Yes / max. 40 A 2 A / DI, Safety fuse 2...3 A, Char. C, Circuit breaker 3 x 400...3 x 500 V AC (Wide-range input) 3 x 340...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC in accordance with UL 508) 0.6 A @ 3 x 500 V AC / 0.8 A @ 3 x 400 V AC 0.4 A @ 800 V DC / 0.7 A @ 450 V DC Yes / max. 50 A 2 A / DI, Safety fuse 2...3 A, Char. C, Circuit breaker 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 5 A up to 55 °C 5 A @ 55 °C, 3.75 A @ 70 °C 6 A for 1 min, ED = 5 % Unrestricted 30…35 V DC 35 V DC 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 10 A up to 55 °C 10 A @ 55 °C, 7.5 A @ 70 °C 12 A for 1 min, ED = 5 % Unrestricted 30…35 V DC 35 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC 87 % @ 3 x 500 V AC / 88 % @ 3 x 400 V AC 6 W / 13 W < 1 mA > 0.4 @ 3 x 500 V AC / > 0.45 @ 3 x 400 V AC > 40 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC yes, max. 5 125 / 40 / 100 mm / 0.6 kg 88 % @ 3 x 500 V AC / 89 % @ 3 x 400 V AC 8 W / 26 W < 0.5 mA > 0.45 @ 3 x 500 V AC / > 0.5 @ 3 x 400 V AC > 40 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC yes, max. 5 125 / 60 / 100 mm / 1 kg CE, TÜV (EN/IEC 60950-1), cULus (Pending) Input Output Screw connection Screw connection 4 for L1/L2/L3/PE 6 (13,14,+,+, - -) 0.18/6 0.5/6 0.5/2.5 0.5/2.5 26/10 26/12 0.5/0.6 0.5/0.6 8 6 CE, TÜV (EN/IEC 60950-1), cULus (Pending) Input Output Screw connection Screw connection 4 for L1/L2/L3/PE 6 (13,14,+,+, - -) 0.18/6 0.5/6 0.5/2.5 0.5/2.5 26/10 26/12 0.5/0.6 0.5/0.6 7 6 Type PRO ECO3 120W 24V 5A Type PRO ECO3 240W 24V 10A Qty. 1 Order No. 1469530000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. Qty. 1 Order No. 1469540000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. 1460790000 – 2014/2015 PRO ECO3 480W 24V 20A PROeco Switch-mode power supplies connectPower PROeco PRO ECO3 960W 24V 40A A L1 (+) L2 (–) AC L3 PE + + – – – 13 14 DC Pay attention to polarity of DC connection L1 (+) L2 (–) AC L3 PE + + – – – 13 14 DC Pay attention to polarity of DC connection Technical data Input Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal) / inrush current Recommended back-up fuse Output Rated output voltage Output voltage Ramp-up time / residual ripple, switching peaks Rated output current @ Urated Continuous output current @ 24 V DC Power boost @ 24 V DC, 60 °C Capacitive load Protection against reverse voltages from the load Protection against internal surge voltage Signalling DC OK Alarm Error Voltage monitoring / no-voltage contact / contact load On/Off relay General data Efficiency Power loss @ idling / nominal load Earth discharge current Power factor (approx.) Mains buffering @ Irated Parallel connection option Height x width x depth / weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil Min./max. tightening torque range Stripping length Note Ordering data Note 1460790000 – 2014/2015 mm² mm² min/max Nm mm 3 x 400...3 x 500 V AC (Wide-range input) 3 x 340...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC in accordance with UL 508) 1.2 A @ 3 x 500 V AC / 1.5 A @ 3 x 400 V AC 0.7 A @ 800 V DC / 1.2 A @ 450 V DC Yes / max. 50 A 4 A / DI, Safety fuse 3...5 A, Char. C, Circuit breaker 3 x 400...3 x 500 V AC (Wide-range input) 3 x 340...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC in accordance with UL 508) 2.15 A @ 3 x 500 V AC / 2.68 A @ 3 x 400 V AC 1.37 A @ 800 V DC / 2.37 A @ 450 V DC Yes / max. 40 A 6 A / DI, Safety fuse 10 A, Char. B, Circuit breaker 6...8 A, Char. C, Circuit breaker 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 20 A up to 55 °C 20 A @ 55 °C, 15 A @ 70 °C 24 A for 1 min, ED = 5 % Unrestricted 30…35 V DC 35 V DC 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 40 A up to 50 °C 40 A @ 50 °C, 24 A @ 70 °C 48 A for 1 min, ED = 5 % Unrestricted 30…35 V DC 35 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC 89 % @ 3 x 500 V AC / 90 % @ 3 x 400 V AC 8 W / 48 W < 0.5 mA > 0.41 @ 3 x 500 V AC / > 0.43 @ 3 x 400 V AC > 30 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC yes, max. 3 125 / 100 / 120 mm / 1.3 kg 90 % @ 3 x 500 V AC / 91 % @ 3 x 400 V AC 5 W / 95 W < 1 mA > 0.56 @ 3 x 500 V AC / > 0.56 @ 3 x 400 V AC > 25 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC yes, max. 3 125 / 160 / 120 mm / 2.5 kg CE, TÜV (EN/IEC 60950-1), cULus (Pending) Input Output Screw connection Screw connection 4 for L1/L2/L3/PE 7 (13,14,+,+, - ,-,-) 0.18/6 0.18/6 0.5/2.5 0.5/2.5 26/10 26/10 0.5/0.6 0.5/0.6 7 7 CE, TÜV (EN/IEC 60950-1), cULus (Pending) Input Output Screw connection Screw connection 4 for L1/L2/L3/PE 7 (13,14,+,+, - ,-,-) 0.18/6 0.5/16 0.5/2.5 2.5/10 26/10 22/8 0.5/0.6 1.2/1.5 7 12 Type PRO ECO3 480W 24V 20A Type PRO ECO3 960W 24V 40A Qty. 1 Order No. 1469550000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. Qty. 1 Order No. 1469560000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. A.9 Switch-mode power supplies connectPower PROeco connectPower PROeco diode module CP DM 10 CP DM 20 A +V E1 E2 –V –V DC E1 E2 –V -V +V -V + +V –V DC – E1 E2 -V E1 E2 -V Technical data Input Input voltage Input current Output Output voltage Output current General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Mounting position, installation notice Installation advice Weight Approvals Dimensions Clamping range (nominal / min. / max.) Depth x width x height Note mm² mm 40 V DC max. 2 x 0...10 A max. 40 V DC max. 2 x 0...20 A max. Uin - 0.5 V typical 0...20 A max. or 10 A max. for redundancy operation Uin - 0.5 V typical 0...40 A max. or 20 A max. for redundant operations -10 °C...+55 °C -20 °C...+85 °C 95.5% horizontally, on terminal rail TS 35 Space: side ≥ 2 cm; above/below ≥ 10 cm 0.4 kg CE; cULus; cURus -10 °C...+55 °C -20 °C...+85 °C 97.5% horizontally, on terminal rail TS 35 Space: side ≥ 2 cm; above/below ≥ 10 cm 0.4 kg CE; cULus; cURus Input 4 / 0.13 / 6 110 / 55.5 / 125 Input 4 / 0.13 / 6 110 / 55.5 / 125 Output 4 / 0.13 / 6 110 / 55.5 / 125 Output 10 / 0.32 / 16 110 / 55.5 / 125 Ordering data Screw connection Type CP DM 10 Qty. 1 Order No. 8710620000 Type CP DM 20 Qty. 1 Order No. 8768650000 Note Accessories Note A.10 1460790000 – 2014/2015 Small metal foot Type MTA 30 MF Large metal foot Order No. 1251320000 Small wall mounting Type CP A WALLADAPTER 30 MM Small plastic foot Type MTA 45 MF Order No. 1251310000 Type MTA 30 BK Switch-mode power supplies PROeco - Accessories Large plastic foot Order No. 1168970000 Type MTA 45 BK Order No. 1962250000 A Large wall mounting Order No. 1461870000 Type CP A WALLADAPTER 45 MM Order No. 1461850000 Small screwdriver Type SDIK PH1 SDIS 0.5X3.0X100 Blade type Size/AF 1.00 B a b 0.5 3 c 80 100 Order No. 9008570000 9008380000 End bracket Markers For DIN rail TS 35 Type SM 18/9.5 K MC NE WS 1460790000 – 2014/2015 Colour white Qty. 200 Order No. 1248580000 Polyamide with fibre glass, screwable WEW 35/1 SW Colour black Torque 1.2 Nm Qty. 50 Order No. 1162600000 A.11