SEE_Test_Report_RH1011.pdf

Heavy-Ion Test Results of the Voltage Comparator RH1011M
18 September 2012
Sana Rezgui1, Rocky Koga2, Dave Harvey3, Steve Lalumondiere2, Jeffrey George2, Neal
Nickles4, Stephen Moss2, Robert Dobkin1, and Rafi Albarian1
1
3
Linear Technology, 2The Aerospace Corporation
Northrop Grumman Corporation, and 4Ball Aerospace
Acknowledgements
The authors would like to thank the Application Signal Conditioning Group Tim Regan, Jim
Mahoney, and Antonina Karpova, from Linear Technology for their help with the board design
and assembly as well as Steve Bielat and Jeffrey George from The Aerospace Corporation for
their assistance with the beam experiments. Special Thanks to the Aerospace Corporation team,
mainly David Meshel, and Rocky Koga, for their expediting these experiments.
1
Executive Summary
This report details the heavy-ion test experiments performed on the RH1011M at the Lawrence Berkeley
National Labs (LBNL). The RH1011M [1] is a general purpose comparator with significantly better input
characteristics than the LM111. Heavy-ions induced SEE (Single Event Effect) experiments included
Single Event Transient (SET), Single Event Upset (SEU) and Single Event Latchup (SEL) tests up to an
LET of 114 MeV.cm2/mg at elevated temperatures (to case temperatures of 100°C). Under heavy-ion
irradiations, with various inverting input bias conditions (proportional to differential input voltage as the
non-inverting input voltage is fixed), the RH1011M showed sensitivities only to SETs. Beam tests
confirmed the SEL and SEU immunity of this part in all test conditions. With the appropriate filtering
capacitance at the output, the RH1011M was fully-mitigated to SET. The measured SET sensitive crosssection is about 1.6% of the total die’s area. Because of the small difference in the offset voltage (VOS)
with temperature (2mV at room and 4mV at 125°C), the SEE test results were not dependent on the
temperature. However, when the comparator differential input voltage was very close to the offset voltage
(VOS) or the inverting input voltage to the hysteresis boundary voltages, the SET pulse-width (PW) was
the widest, and the measured SET cross-sections were the highest. At higher LET near the limiting crosssection, the dependence on differential input bias becomes less significant, as most SETs become wide.
The SET cross-sections dependence on these biases could be simply due to the peripheral capacitances
charge/discharge times, so what might seem as bias dependence is truly related to parasitic time constants.
We believe that the initial SET-PW will depend on the circuit response and the flux but its propagation on
its parasitic and the ion’s diffusion [4]. Careful selection of the circuit parasitic is crucial when operating
the circuit in radiation beams, as they can change the time constants for signal propagation and widen the
radiation-induced transients. This circuit can be used as is, as the widest measured SET-PW is about the
comparator’s response time. However, for accurate selection of the SET filter or for the circuit peripheral
parasitic, we would recommend that the designer simulates his design by injecting SETs at the circuit
inputs/outputs, as wide as the DUT maximum response time, as well as varying the bias during these
injections. This could be accomplished by the LTSpice tool offered by Linear Technology, as most of the
Linear LT parts spice models are offered [5]. That should provide guidance to the designer but the result
should be correlated with laser and beam tests as most of the RH and LT parts differ in their process and
sometimes in their design as well. The wrong selection of these parasitic can make things worse and
widen the SET from nanoseconds to microseconds, making it harder on the following circuit to not
propagate them.
2
1. Overview
This report details the heavy-ion test experiments performed on the RH1011M at the Lawrence Berkeley
National Labs (LBNL). The RH1011M is a general purpose comparator with significantly better input
characteristics than the LM111. It offers four times lower bias current, six times lower offset voltage and
five times higher voltage gain. The RH1011M retains all the versatile features of the LT1011, including
single 3V to ±18V supply operation, and a floating transistor output with 50mA source/sink capability. It
can drive loads referenced to ground, negative supply or positive supply, and is specified up to 36V
between V– and the collector output. A differential input voltage up to the full supply voltage is allowed,
even with ±18V supplies, enabling the inputs to be clamped to the supplies with simple diode clamps. The
RH1011M voltage offset (VOS) does not exceed ±4mV across the full range of the spec’d die junction
temperature (-55°C to 125°C).
The wafer lots are processed to Linear Technology’s in house Class S flow to yield circuits usable in
stringent military applications. The device is qualified and available in three different hermetically sealed
packages (8-Lead CERDIP (J8), 10-Lead flatpack (W10) and 8-Lead TO-5 Metal Can (H8)). More details
are given about this voltage comparator in [1, 2 and 6]. This is a 7um technology using exclusively
bipolar transistors. The part’s block diagram is shown in Fig. 1. The H and W package designations are
given in Figs. 2 and 3.
Absolute Maximum Ratings
Supply Voltage
Output to Negative Supply
Ground to Negative Supply
Differential Input Voltage
Voltage at STROBE Pin
Input Voltage
Output Short-Circuit Duration
Operating Temperature Range
Storage Temperature Range
Lead Temperature (Soldering, 10 sec)
36V
35V
30V
35V
5V
Equal to Supplies
10 sec
-55ºC
-65ºC
300ºC
3
Fig. 1: Block Diagram of the RH1011M DIE
Fig. 2: RH1011M in H Package
4
Fig. 3: RH1011M in W Package
Table 1 summarizes the parts’ features and the electrical test equipment.
Table 1: Test and Part’s Information
Generic Part Number
RH1011M
Package Marking
RH1011
Date Code
Manufacturer
Linear Technology
Fabrication Lot/Lot Date Code (LDC)
570900.1/1013A, 140392.2/9721B
Quantity tested
4
Dice Dimension
2.032 X 1.219 mm2≈ 2.477 mm2 ≈ 1/40 cm2
Part Function
Voltage Comparator
Part Technology
BIPS700
Package Style
Hermetically sealed flat-10, Metal can-8
Test Equipment
Power supply, digital oscilloscope, multimeter,
and computer
Temperature and Tests
SET, SEU and SEL @ Room Temp. and 100°C
5
2. Test Setup
Custom SEE boards were built for heavy-ion tests by the Linear Technology team, based on provided
schematics from The Aerospace Corporation, Northrop Grumman and Ball Aerospace engineers. The
RH1011MW and RH1011MH parts were tested at LBNL on Sept. 2012 at two different temperatures (at
room temperature as well as at 100°C). During the beam runs, we were monitoring the temperature of the
adjacent sense transistor (2N3904) to the DUT but not the die temperature (junction temperature). Hence
the test engineer needs to account for additional temperature difference between the dice and the sense
transistor, which was not measured in vacuum. In-air, both of the case and the sense transistor
temperatures were measured to be the same. The temperature difference between the junction of the die
and the case is a function of the DUT power dissipation multiplied by the thermal resistance Rtheta-JC(ƟJC).
With no heating, the temperature of the adjacent temperature sense transistor (2N3904) to the DUT (or
the DUT case) was measured on average at about 35°C. The junction temperature was not measured in
vacuum; its calculation is provided in Eq.1. This value was correlated in-air with a thermocouple.
TJ= TC+ PD* ƟJC
(1)
Where: TJ is the junction temperature, TC the case temperature, PD the power dissipated in the die and ƟJC
the thermal resistance between the die and the case. Note: A relatively small amount of power is
dissipated in other components on the board. The sense transistor temperature (very similar to the case
one) during each run is shown in Tables 2 and 3. That is not considered in this calculation.
The calculation of the dissipated power in the die is provided in Eq. 2:
PD = Pin- Pout= |V+ * I+| + |V- * I-| - Pout
(2)
Where:
1. V+ is the positive voltage supply
2. V- is the negative voltage supply
3. I+ is the positive current supply
4. I- is the negative current supply
5. Pin: Input Power Dissipation
6. Pout: Output Power Dissipation
Assuming that Pout =0 and in the case where:
Tc = 30°C; V+= 12V; V-= -12V; I+ = 2.5mA; I- = 5.2mA; and ƟJC= 40°C/W [6],
PD= 92.4mW and TJ≈34°C
Fig. 4: Photography of the Decaped RH1011MW Dice
6
Two SEE test boards have been manufactured; the first one is called the hysteresis board and the second
one VOS board. The naming of each board is a reflection of the part’s most sensitive area in the beam,
where SETs are the widest and their respective SET cross-sections are the highest. In the case of the
hysteresis board, it is between 554 and 610mV, while for the VOS board at maximum junction
temperature, it is between -4 and 4mV. For instance, the hysteresis board contains:
-
The DUT with open-top (as shown in Fig. 4)
The filtering caps for the voltage supplies (V- (-12V), V+ (+12V), VRef (+5V), VD (+5V))
A filtering capacitance for the output (0.1uF used only for the filtering case)
The hysteresis circuit (R1, R7 and R8 resistors)
The 2N3904 bipolar transistor to sense the board temperature
For the Hysteresis board, the beam tests were run with and without the capacitance C6. This capacitance
was added by the NGC engineers mainly for the mitigation of SETs that might occur on the 5VREF
signal, originating from a peripheral circuit other than the RH1011M. It is not required for the RH1011M
circuit and the data provided in the remaining of this report will demonstrate its non-impact on the
obtained SET data. Figs. 5 and 6 show the SEE test board schematics. The pictures of these boards are
given in Figs. 7 and 8.
Fig. 5: Block Diagram of the RH1011MW SEE Hysteresis Board
7
Fig. 6: Block Diagram of the RH1011MW SEE VOS Board
To minimize the distortion of the measured SET-PW, the test setup was placed as close as possible to the
vacuum chamber. It is connected with two 3 ft long BNC cables to two Agilent Power Supplies (PS)
(N6705B) and to a Tektronix oscilloscope (TDS6604B 1GHz, 2GS/s) to view the output signal (Vout).
The first PS supplies the input voltages to the SEE test board and allows the automated logging and
storage every 0.5 ms of the current input supplies (Iin), as well as the automation of power-cycles after
the detection of a current spike on the input current that exceeds the current limit set by the user. The
second PS is used for sensing the voltages of the input power supplies. This was done to avoid any
interference from the power supplies that might cause widening of the transients upon the occurrence of
an SET. The output pin (Vout) was also connected through two 3 ft BNC cables (vacuum chamber feedthrough) to the scope. For better accuracy, the equivalent capacitive load of these cables should be
calculated and accounted for, as it might affect the SET pulse width and shape. In this case, the cables
capacitive load was about 250 pF. Note that during the laser tests, these BNC cables were replaced with a
scope probe with an equivalent capacitive load about 10pF to minimize the distortion of the SET pulse.
As the beam test results did not vary with the package (H and W), except for the SEU data, all SET data is
extracted from the heavy-ions tests on the W packaged DUTs.
8
Fig. 6: Photograph of the first SEE Test Board (Hysteresis Board)
Fig. 7: Photograph of the Second SEE Test Board (VOS Board)
9
3. Heavy-Ion Beam Test Conditions
The RH1011M part was tested under various input bias conditions ranging from 50 to 1000mV in the
case of the hysteresis board and from -200 to 200mV in the case of the VOS board. The selected beam
energy is 10MeV/nucleon, which correlates with beam ions delivered at a rate of 7.7 MHz (eq. to a period
of 130 ns). During these 130 ns, the ions are generated only within very short pulses that last for 10 ns, as
shown in Fig. 8. At every pulse of 10 ns, N number of particles per square centimeter, depending on the
flux, will be irradiating the DUT. The calculation of N is provided in Eq. 3:
N= Flux *130ns
(3)
Fig. 8: Particle Emission during a Beam Run at Beam Energy of 10 MeV/nucleon; Emission Frequency = 7.7MHz
For instance if the flux equals 104 particles/cm2/second, the probability (N) of having a particle emitted
and striking within a defined square centimeter within a random 10ns active period and even during the
entire period of 130 ns is 1.30x10-3. Multiply that value by the die area to determine the probability of a
particle striking the die; 1.30x10-3 particles/cm2 * 2.477 10-2 cm2 = 3.22x10-5. We don’t know exactly at
what pulse this particle will be irradiating the DUT. The random nature of that emission will change the
elapsed time between any two consecutive particles. The higher the beam’s frequency or the flux; the
higher is the likelihood to have more than one particle hitting the DUT in a very short time (within
hundreds of nanoseconds). Indeed, the minimum time that is guaranteed by the facility to separate the
occurrences of two particles can be as low as 130 ns but the probability of that happening is very low. To
avoid overlapping of events, it is important then that the error-events last less than 130 ns or that the flux
is much reduced.
Most importantly, in the case of these analog devices (power, signal conditioning, etc.), some of the
DUT’s transistors when hit by heavy-ions will cause wide SETs that might last for microseconds. To
make sure that the error-rate calculation is accurate, the flux needs to be reduced until there is a
consistency in the number of detected errors with the flux for a given ions’ fluence. If that’s not the case,
the part is subject to multiple hits or SET widening from the peripheral parasitic. In these types of circuits,
it is most likely to be the latter. The test engineer needs to account for the SET widening that the
peripheral RC filters are causing. In other terms, if the original SET is widened at the DUT output, by the
peripheral RC circuits or even the ones used to mitigate it, then the resulting event will dictate the
maximum flux to be applied on the DUT. For instance, if the original SET is 600ns wide, while the
mitigated SET is 200us (although with much lower amplitude) then the flux while testing the mitigated
design should be less than 5E3 particles/cm²/sec.
10
Although the traditional obvious solution is to use RC filters, SET mitigation solutions such as the ones
based on using guard-gate solutions for analog circuits might be more suitable in some cases as they will
mitigate the SET without widening it [4]. As a result, comparators can keep their original fast response
advantage but at the same time be SEE immune.
During the RH1011M SEU tests, we have noticed that there are usually three flux regions: 1) a threshold
flux where for any flux below that value, the probability of multiple hits (double or higher) is extremely
low and therefore negligible, 2) an instable region where the increase of the flux at a given LET and a
given fluence will increase the SEE cross-sections almost linearly, and 3) a plateau or saturation region
where the part is saturated meaning that the number of multiple hits won’t make any difference anymore
as the part has reached its saturation. Measured SEE cross-sections that will correlate best with orbital
error-rates in space environment should use a flux that is lower than the threshold flux (region 1).
We have observed dependence of the SEE sensitivity on the flux in the case of the RH1011M. When
operating the part in the hysteresis region (between 550 and 615mV), the error-signature of the
comparator will change from an SET to an SEU at fluxes that are higher than 4E+3 particles/cm2/sec,
which is an artificial effect of the high beam fluxes, that won’t be seen in space environments where ions
fluxes are extremely low. In this case, this effect was expected as the PW of the detected SETs, with 10uF
at the comparator output, were about 200us. Laser tests showed the same results when we increased the
laser repetition rate (LRR). They also showed the effect of consecutive events even at low LRR. Indeed,
in the hysteresis region, with low LRR, if we don’t remove the laser injection, an SET will become an
SEU after many injected laser pulses, showing the impact of the internal die and the circuit parasitic, in
changing the shape of the propagated SET, if they did not fully recover from the previous laser injection.
The laser test results showed 1) the effects of varying the laser repetition rate (equivalent to flux) and 2)
the effects of consecutive injections even at low LRR (eq. to low fluxes). Single-shot SETs are then
needed to avoid the overwhelming of the circuit’s intrinsic and cross-coupling capacitances and mimic the
real space environment fluxes. The run average and maximum fluxes during the heavy-ions tests are
reported in Tables 2 and 3.
11
4. Radiation Test Results
Heavy-ions SEE experiments included SET, SEU and SEL tests up to an LET of 114 MeV.cm2/mg at
elevated temperatures (to case temperatures of 100°C). The RH1011M parts were irradiated under various
bias conditions in 172 runs. Because of the cabling between the SEE test board and the scope, that adds a
minimum capacitive load on the output signal of about 250pF, the 1nF input capacitances, the serial
resistances on the comparator inputs and the feedback path (resistances and capacitances), the final
measured SET-PW on the scope can be much wider than the initial SET-PW originating from the DUT
output. Ideally, the SET-PW on the DUT output should be about the comparator response time, which is
less than 400ns at a 1V maximum step-size [2]. Once the hit input transistor has trigged to the ion’s
deposited charge, the part will need approximately the sum of the circuit response time (about 400ns) to
rising and falling edges (Figs. 9 and 10).
Fig. 9: DUT Responses Times to 100mV Rising and Falling Input Steps (Y-axis units are in Volts)
Fig. 10: Propagation Delay vs. Input Size
12
Furthermore, for SETs that have a voltage increase (negative edge) or voltage drop (positive edge) that is
higher than 1V, for instance 5V, the comparator response time will increase to about 600ns, as shown in
Fig. 10. The resulting SET will be widened by the BNC cables eq. capacitive load, hence the wide
observed SETs (up to 2us) even when we don’t use a filtering capacitance. The heavier is the ion, the
larger are the deposited charge and its diffusion, the higher is the SET amplitude and hence the wider is
the comparator response time to the SET.
In addition, in the hysteresis region between 550 and 615mV (Fig. 11), the comparator output signal
depends on the input voltage levels as well as on the current output state. If the inverting input signal is
lower than 550mV, the output state will remain high (5V), but if higher than 615mV, the output state will
toggle low (0V), independently of the current output state. Between 550 and 615mV, if the current output
state is high, the output remains high. Once it exceeds 610mV, the output voltage will flip from 5 to 0V.
However, when decreasing the input voltage to a value that is higher than 550mV, the output will remain
low and will flip high only when the input bias drops below 550mV. In-beam, this might seem as an SEU.
Indeed, if the initial input voltage is at 575mV and the output voltage is at 5V, an ion hit that will trigger
an SET with negative 5V amplitude will toggle the output voltage from 5 to 0V and keep it at 0V even
after the complete diffusion of the SET effect. The only way to toggle the output high is to power-cycle
the comparator or to drop the input voltage below 550mV. It is then not recommended to operate or test it
in this region, as it should be. This can also be reproduced on the bench without radiation, by varying the
input supply voltage and monitoring the output. Note that the designer can change the voltage settings for
this region by varying the resistance values of R7 and R8, shown in Fig. 5. For instance, decreasing these
values from 50 to 5 Kohms, will shift this region from (550 to 615 mV) to (2.575 to 2.635V). In the
following, SEU Data is shown for information only and are used to demonstrate the dependence of the
SEU cross-sections on the flux.
Output Voltage
5V
Hysteresis
Region
550 mV
615 mV
Inverting Input
Voltage
Fig. 11: A Comparator Output Voltage vs. Input Voltage in the Hysteresis Region, when the noninverting input voltage is at 550mV
13
1) False SEU Detection in the Hysteresis Region
The SEU tests consisted of varying the input voltage levels from 550 to 615mV (hysteresis region) and
observing the output state. Upsets have only been observed for non-inverting input voltage ranging
between 575 and 615mV; this part can then be considered SEU immune. As shown in Fig. 12, increasing
the flux from (1E4p/cm2) to (8E5p/cm2) increased the “SET-induced SEU” cross-section by an order of
magnitude. This is simply the result of SET widening caused by the DUT and the circuit peripheral
parasitic. In this case, it is the latter that causes the overlapping of the latent effects of consecutive SETs.
As the next event occurs before the complete capacitor charge/discharge due to the previous transient, the
part will accumulate the effects of consecutive events at high fluxes, similar to the effects of METs
(Multiple Event Transients). If these parasitic are defeated by the SET and cannot filter it, they will
reduce its amplitude but widen it [4].
The same principle applies to the internal die structures, these analog circuits have big capacitance values
that are also widening internally these events and therefore need adequate time to completely propagate
the event to the DUT output. Note that at a flux of 2E5p/cm2, we have not seen any SEU up to a fluence
of 1E8p/cm2. At this moment, we don’t know the reasons behind this. Once the maximum SET-PW has
been measured (600ns if we don’t consider the widening effects from the parasitic circuits), SET
mitigation can be achieved by using the most adequate RC filter at the comparator output. During the
beam tests, the run fluxes should be reduced to account for this. Since this part is only SET sensitive, only
SET-data will be discussed in the remainder of this report.
1.E-06
SEU Cross-Section (cm2/DUT-HPkg)
In=575mV; No 0.1uF cap at output
In=575mV; with 0.1uF at the output
1.E-07
Kr=30.8MeV.cm2/mg
1.E-08
1.E-09
0.E+00
2.E+05
4.E+05
6.E+05
8.E+05
1.E+06
Flux (p/cm2)
Fig. 12: SEU Cross-Section vs. Beam Flux when operating the RH1011MH in the Hysteresis Region,
(Hysteresis board is shown in Fig. 5)
14
2) SET Detection Without Filtering (Without a capacitance at the Output Signal)
For SET detection, using the Hysteresis board, the beam tests consisted of varying the input voltage from
50 to 1000 mV and triggering the scope on positive and negative SETs occurring on the comparator
output signal. For negative SET detection, the scope was set to trigger on switching negative pulse width
from 5V to lower than 4.3V. For positive SET detection, the scope was set to trigger on an amplitude
increase of about 1V from 200mV. The raw heavy-ion test results are summarized in Tables 2 and 3,
showing SET sensitivities on the output. The data showed two SET-types. The first SET-type is short and
of small amplitude, as shown in Fig. 13. The second SET-type was as wide as 2us, as shown in Fig. 14,
while its cross-sections varied with the inverting input bias, which is proportional to the differential input
voltage as the non-inverting input voltage is fixed.
Fig. 13: Short SET on the DUT Output; Vin=450mV; Vout=5V - Run 27; Case Temperature = 34.5°C
Fig. 14: Wide SET on the DUT Output; Vin=450mV; Vout=5V - Run 27; Case Temperature = 34.5°C
15
Under heavy-ion irradiations, with various differential input bias conditions, the RH1011M showed small
sensitivities to SETs. Figs. 15 to 19 summarize the SET cross-sections at various biases. The measured
SET sensitive cross-section is about 1.6% of the total die’s area. Because of the small difference in the
offset voltage (VOS) with temperature (2mV at room and 4mV at 125°C), the SEE test results were not
dependent on the temperature. However, when the comparator differential input voltage is very close to
the offset voltage (VOS) in the case of the VOS board or the inverting input bias close to the hysteresis
boundary voltages in the case of the hysteresis board, the SET pulse-width (PW) is the widest, and the
measured SET cross-sections are the highest. The inverting input bias (at test point E6, Fig. 5) is
proportional to the differential input bias as the non-inverting input bias is fixed, in the case of the
hysteresis board and grounded in the case of the VOS board. Hence, the lower the comparator input
differential bias is, the higher the SET cross-section is. Generally, the smaller is the comparator
differential input bias, or the closer we are to the hysteresis region, the higher are the part’s susceptibility
to trigger and the resulting SET cross-sections [3]. At higher LET near the limiting cross-section, the
dependence on differential input bias becomes less significant, as most SETs become wide.
The SET cross-sections dependence on these biases could simply be due to the peripheral capacitances
charge/discharge times, so what might seem as bias dependence is truly related to parasitic time constants.
We believe that the initial SET-PW will depend on the circuit response and the flux but its propagation on
its parasitic and the ion’s diffusion [4]. Note that the addition of the C6 capacitance in the feedback path
did not make a difference in the overall SET cross-sections.
16
1.E-03
SET Cross-Section (cm2/RH1011M)
Hysterisis
Region
1.E-04
1.E-05
1.E-06
Xe (58.78) With C6
Xe (58.78) Without C6 (100C))
Kr (30.86) With C6
Ar (9.74) With C6
Si (6.09) With C6
1.E-07
0.0
0.2
0.4
Xe (58.78) Without C6
Xe (117.56) Without C6 (100C)
Cu (21.17) With C6
Ar (9.74) Without C6
Si (6.09) Without C6
0.6
0.8
1.0
Inverting Input Bias @ test point E6 in Fig. 5 (V)
Fig. 15: Measured SET Cross-Sections, Using the Hysteresis Board, without Filtering vs. Inverting Input
Bias (at test point E6, Fig. 5), LET, Temperature, With and Without C6 Capacitor
17
SET Cross-Section (cm2/RH1011M)
1.E-03
Kr (30.86) With C6 cap = 0.1uF
1.E-04
1.E-05
1.E-06
Kr (30.86) With C6
1.E-07
0.0
0.5
1.0
1.5
2.0
Inverting Input Bias @ test point E6 in Fig. 5 (V)
Fig. 16: Measured SET Cross-Sections, Using the Hysteresis Board vs. Inverting Input Bias. This graph
shows clearly the SET cross-sections dependence on the inverting input bias when used in the hysteresis
configuration. In this case, the inverting input bias (at test point E6, Fig. 5) is proportional to the
differential input bias as the non-inverting input bias is fixed. Hence, the lower the comparator input
differential bias is, the higher the SET cross-section is.
18
1.E-03
SET Cross-Section (cm2/RH1011M)
Without C6 Cap =0.1uF
1.E-04
1.E-05
Output flips from 5V to 0V
Output flips from 0V to 5V
1.E-06
Close to
Hysterisis
Region
0.05
0.30
0.35
0.40
0.54
0.62
0.70
0.80
0.90
1.00
1.E-07
0
10
20
30
40
50
60
70
LET (MeV.cm2/mg)
Fig. 17: Measured SET Cross-Sections, Using the Hysteresis Board vs. LET, and the Inverting Input Bias
at Test Point E6 (Fig. 5), without the capacitance C6
Arrows pointing down are indication of no observed SETs up to that fluence at a given LET
19
1.E-03
SET Cross-Section (cm2/RH1011M)
With C6 Cap =0.1uF
1.E-04
1.E-05
Close to
Hysterisis
Region
Negative Transients from 5V to 0V
1.E-06
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.54
1.E-07
0
10
20
30
40
50
60
70
LET (MeV.cm2/mg)
Fig. 18: Measured SET Cross-Sections, Using the Hysteresis Board vs. LET, and the Inverting Input Bias
at Test Point E6 (Fig. 5), using the capacitance C6
Arrows pointing down are indication of no observed SETs up to that fluence at a given LET
20
1.E-03
SET Cross-Section (cm2/RH1011M)
With C6 Cap =0.1uF
1.E-04
1.E-05
Positive Transients from 0V to 5V
1.E-06
Close to
Hysterisis
Region
1.E-07
0
10
0.62
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.00
2.00
20
30
40
50
60
70
LET (MeV.cm2/mg)
Fig. 19: Measured SET Cross-Sections, Using the Hysteresis Board vs. LET, and the Inverting Input Bias
at the Test Point E6 (Fig. 5)
Arrows pointing down are indication of no observed SETs up to that fluence at the tested LET
This does not eliminate the possibility of noise for the second type of SETs as once the noise levels have
caused the device in a circuit to trigger, its propagation will mostly depend on its layout and parasitic
(capacitive load and resistances). In such a circuit, the capacitive load is high and will cause the resulting
SET to become as wide as the maximum circuit response time. As mentioned above, the cabling
capacitance, the feedback path and the two parallel input capacitances in serial with the resistances at the
comparator inputs will make all the difference. A good printed circuit board designed to be minimally
sensitive to noise, electromagnetic effects, with no ground loops, etc. is required for the SEE tests of such
type of circuits.
21
3) SET Detection With Filtering (with a 0.1uF capacitance at the Output Signal)
For mitigation purposes, we’ve run the beam experiments with an equivalent capacitance at the output
signal of 0.1uF on the hysteresis board and 22nF on the VOS board. Fig. 20 shows an example of SET on
the output signal. In both cases, SETs were fully-mitigated with the added output capacitance up to an
LET of 114 MeV/cm2/mg and high temperature of 100°C on the sense transistor, as shown in Tables 2
and 3. Fig. 21 shows that a 22nF was sufficient to fully mitigate large amplitude and wide SETs.
However, based on additional laser tests, we have demonstrated that a larger capacitance (0.1uF) was
needed in the hysteresis board but not in the VOS board, showing that the feedback path was widening
these SETs.
Fig. 20: SET Waveform with SET filtering (using 0.1uF) on the DUT Output; Vin=450mV; Vout=5V;
Case Temperature = 34.5°C
22
1.E-02
Xe with Filter_very short SETs
Ag with Filter_very short SETs
SET Cross-Section (cm2/RH1011)
Xe without Filter
1.E-03
Ag without Filter
1.E-04
1.E-05
1.E-06
1.E-07
-0.3
-0.2
-0.1
0.0
0.1
0.2
0.3
Inverting Input Bias @ test point E6 in Fig. 6
Fig. 21: Measured SET Cross-Sections, Using the VOS Board (Fig. 6, at test point E6), vs. Inverting
Input Bias, LET, with and without 22nF capacitance at the comparator output. In this case, the negative
voltage corresponds to the inversion of the bias polarity of the non-inverting input of the comparator
Arrows pointing down are indication of no observed SETs up to that fluence at tested LET
23
4) SET Cross-sections With/Without Filtering at hot (100°C)
With 0.1uF at the comparator’s output and at high temperature (100°C) at the DUT case, the test results
(green circles in Fig. 22) showed no SET sensitivities at the output voltage up to an LET of 114
MeV.cm2/mg. Without this filtering capacitance, at an LET of 114 MeV.cm2/mg, the measured limiting
cross-section is 4x10-4 cm2/die. This means that the sensitive cross-section on the part is about 4x10-2
mm2, which is about 1.6% of the total die’s area (2.477 mm2).
1.E-03
SET Cross-Section (cm2/RH1011M)
1.E-04
1.E-05
SET with Vin1V; Without Filt. Cap = 0.1uF
SET with Vin=1V; With Filt. Cap=0.1uF
1.E-06
1.E-07
1.E-08
Negative Transients from 5V to 0V during HOT SEL Tests
1.E-09
0
20
40
60
80
100
120
140
LET (MeV.cm2/mg)
Fig. 22: Measured SET Cross-Sections vs. LET, Inverting Input Bias, and Temperature, with and without
Filtering Capacitor (C18=0.1uF) at the Comparator Output
Arrows pointing down are indication of no observed SETs up to that fluence at tested LET
5) SEL Immunity With/Without Filtering (w/o capacitance at the Output Signal)
With 0.1uF at the comparator’s output and at high temperature (100°C) at the DUT case, the test results
(green circles in Fig. 23) showed immunity to SELs up to an LET of 114 MeV.cm2/mg.
24
1.E-03
SET Cross-Section (cm2/RH1011M)
1.E-04
No Single Event Latchup (SEL) at Room Temerature and 100C
1.E-05
SEL Immunity
1.E-06
1.E-07
1.E-08
1.E-09
0
20
40
60
80
100
120
140
LET (MeV.cm2/mg)
Fig. 23: Measured SEL Cross-Sections vs. LET, showing the comparator immunity to SELs
Arrows pointing down are indication of no observed SETs up to that fluence at tested LET
25
Table 2: Raw Data for the Heavy-Ion Beam Runs (Hysteresis Board)
Run
Design
DUT
Tb
(Vacuum)
Vin
Inv.
Input
Bias
Vout
Trig Vout
(°C)
(V)
(V)
(V)
(V)
5
4.36
5
1
No Filtering
1
27
5.40
2
//
1
32
5.05
3
//
1
32
4.55
4
//
1
32
4.05
5
//
1
32
3.55
6
//
1
32
3.05
7
//
1
32
2.55
8
//
1
32
2.05
9
//
1
32
1.55
10
//
1
32
1.05
11
//
1
32
0.55
12
//
1
32
5.05
16
//
1
34.5
6.55
17
//
1
34.5
7.05
18
//
1
34.5
7.55
19
//
1
34.5
8.05
20
//
1
34.5
8.55
21
//
1
34.5
9.05
22
//
1
34.5
9.55
0.54
0.50
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0.50
0.65
0.70
0.75
0.80
0.85
0.90
0.95
Tilt
Angle
Effective Effective
LET
Fluence
Average Maximum
TID
TID (Run)
Flux
Flux
(Cumulative)
degrees
MeV.cm2/
mg
p/sec/cm2 p/sec/cm2
Xe
0
58.78
2.06E+05 1.61E+03 4.43E+03 1.94E+02
1.94E+02
20
9.71E-05
4.36
Xe
0
58.78
4.02E+05 1.88E+03 4.62E+03 3.78E+02
5.72E+02
22
5.47E-05
5
4.36
Xe
0
58.78
3.99E+05 1.64E+03 1.76E+03 3.75E+02
9.47E+02
20
5.01E-05
5
4.36
Xe
0
58.78
2.46E+05 1.68E+03 1.82E+03 2.31E+02
1.18E+03
20
8.13E-05
5
4.36
Xe
0
58.78
3.56E+05 1.37E+03 1.85E+03 3.35E+02
1.51E+03
22
6.18E-05
5
4.36
Xe
0
58.78
4.50E+05 1.95E+03 4.74E+03 4.23E+02
1.94E+03
20
4.44E-05
5
4.36
Xe
0
58.78
6.36E+05 1.56E+03 1.70E+03 5.98E+02
2.53E+03
21
3.30E-05
5
4.36
Xe
0
58.78
3.90E+05 1.79E+03 4.81E+03 3.67E+02
2.90E+03
21
5.38E-05
5
4.36
Xe
0
58.78
7.19E+05 1.63E+03 3.75E+03 6.76E+02
3.58E+03
20
2.78E-05
5
4.36
Xe
0
58.78
8.24E+05 1.61E+03 4.51E+03 7.75E+02
4.35E+03
21
2.55E-05
5
4.36
Xe
0
58.78
5.97E+05 1.72E+03 4.29E+03 5.61E+02
4.91E+03
21
3.52E-05
5
4.36
Xe
0
58.78
3.73E+05 1.66E+03 1.81E+03 3.51E+02
5.26E+03
20
5.36E-05
0
1
Xe
0
58.78
6.40E+04 3.81E+02 4.50E+02 6.02E+01
5.43E+03
20
3.13E-04
0
1
Xe
0
58.78
6.08E+04 1.55E+02 4.68E+02 5.72E+01
5.49E+03
20
3.29E-04
0
1
Xe
0
58.78
8.51E+04 3.27E+02 4.73E+02 8.00E+01
5.57E+03
20
2.35E-04
0
1
Xe
0
58.78
1.26E+05 3.55E+02 4.70E+02 1.19E+02
5.69E+03
20
1.59E-04
0
1
Xe
0
58.78
1.23E+05 5.36E+02 8.92E+02 1.16E+02
5.80E+03
21
1.71E-04
0
1
Xe
0
58.78
1.40E+05 8.07E+02 2.17E+03 1.32E+02
5.94E+03
20
1.43E-04
0
1
Xe
0
58.78
2.85E+05 7.52E+02 8.82E+02 2.68E+02
6.20E+03
40
1.40E-04
Ion
p/cm2
rads(Si)
#SET
rads(Si)
SET CrossSection
cm2/circuit
26
23
//
1
34.5
10.05
Run
Design
DUT
Tb
(Vacuum)
Vin
(°C)
(V)
28
//
1
34.5
4.55
29
//
1
34.5
4.05
30
//
1
34.5
3.55
31
//
1
34.5
3.05
32
//
1
34.5
2.55
33
//
1
34.5
2.05
34
//
1
34.5
1.55
35
//
1
34.5
1.05
36
//
1
34.5
0.55
37
//
1
34.5
6.20
38
//
1
34.5
6.55
39
//
1
37
7.05
40
//
1
37
7.55
41
//
1
37
8.05
42
//
1
37
8.55
43
//
1
37
9.05
44
//
1
37
9.55
45
//
1
37
10.05
46
//
1
37
20.05
1.00
0
1
Xe
0
Inv.
Input
Bias
Vout
Trig Vout
Ion
Tilt
Angle
Effective Effective
LET
Fluence
Average Maximum
TID
TID (Run)
Flux
Flux
(Cumulative)
(V)
(V)
(V)
degrees
MeV.cm2/
mg
p/sec/cm2 p/sec/cm2
5
4.32
Kr
0
30.86
5.45E+05 1.10E+03 2.06E+03 2.69E+02
7.31E+03
20
3.67E-05
5
4.32
Kr
0
30.86
4.70E+05 1.04E+03 1.18E+03 2.32E+02
7.55E+03
20
4.26E-05
5
4.32
Kr
0
30.86
6.11E+05 1.04E+03 1.77E+03 3.02E+02
7.85E+03
22
3.60E-05
5
4.32
Kr
0
30.86
6.80E+05 1.00E+03 1.94E+03 3.36E+02
8.18E+03
21
3.09E-05
5
4.32
Kr
0
30.86
1.00E+06 9.82E+02 1.69E+03 4.94E+02
8.68E+03
16
1.60E-05
5
4.32
Kr
0
30.86
6.27E+05 1.08E+03 1.79E+03 3.10E+02
8.99E+03
23
3.67E-05
5
4.32
Kr
0
30.86
7.24E+05 1.08E+03 1.89E+03 3.57E+02
9.34E+03
20
2.76E-05
5
4.32
Kr
0
30.86
8.42E+05 1.04E+03 1.21E+03 4.16E+02
9.76E+03
20
2.38E-05
5
4.32
Kr
0
30.86
1.00E+06 1.04E+03 1.22E+03 4.94E+02
1.03E+04
19
1.90E-05
0
1
Kr
0
30.86
7.19E+05 1.02E+03 1.67E+03 3.55E+02
1.06E+04
94
1.31E-04
0
1
Kr
0
30.86
4.64E+05 9.04E+02 1.14E+03 2.29E+02
1.08E+04
35
7.54E-05
0
1
Kr
0
30.86
4.63E+05 9.64E+02 1.62E+03 2.29E+02
1.11E+04
28
6.05E-05
0
1
Kr
0
30.86
5.93E+05 8.93E+02 1.15E+03 2.93E+02
1.14E+04
20
3.37E-05
0
1
Kr
0
30.86
5.25E+05 9.56E+02 1.86E+03 2.59E+02
1.16E+04
21
4.00E-05
0
1
Kr
0
30.86
4.60E+05 9.30E+02 1.20E+03 2.27E+02
1.18E+04
21
4.57E-05
0
1
Kr
0
30.86
5.32E+05 9.48E+02 1.17E+03 2.63E+02
1.21E+04
20
3.76E-05
0
1
Kr
0
30.86
3.78E+05 8.63E+02 1.10E+03 1.87E+02
1.23E+04
20
5.29E-05
0
1
Kr
0
30.86
4.05E+05 1.01E+03 1.76E+03 2.00E+02
1.25E+04
17
4.20E-05
0
1
Kr
0
30.86
1.00E+06 9.88E+02 1.98E+03 4.94E+02
1.30E+04
5
5.00E-06
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0.62
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.00
2.00
58.78
2.85E+05 7.62E+02 8.85E+02 2.68E+02
p/cm2
rads(Si)
6.47E+03
25
8.77E-05
#SET
SET CrossSection
rads(Si)
cm2/circuit
27
47
//
1
39.5
5.40
48
//
1
39.5
5.05
Run
Design
DUT
Tb
(Vacuum)
Vin
(°C)
(V)
51
//
1
39.5
3.55
52
//
1
39.5
3.05
53
//
1
39.5
2.55
54
//
1
39.5
2.05
55
//
1
39.5
1.55
56
//
1
39.5
1.05
57
//
1
39.5
0.55
58
//
1
39.5
6.20
59
//
1
39.5
6.55
60
//
1
39.5
7.05
61
//
1
39.5
7.55
62
//
1
39.5
8.05
63
//
1
39.5
8.55
64
//
1
39.5
9.05
65
//
1
39.5
9.55
66
//
1
39.5
9.55
67
//
1
39.5
5.40
68
//
1
39.5
4.55
0.54
5
4.32
Cu
0
21.17
6.09E+05 1.10E+03 1.31E+03 2.06E+02
1.32E+04
26
4.27E-05
5
4.32
Cu
0
21.17
8.14E+05 1.16E+03 1.29E+03 2.76E+02
1.35E+04
21
2.58E-05
Inv.
Input
Bias
Vout
Trig Vout
Ion
Tilt
Angle
Effective Effective
LET
Fluence
Average Maximum
TID
TID (Run)
Flux
Flux
(Cumulative)
#SET
SET CrossSection
(V)
(V)
(V)
degrees
MeV.cm2/
mg
p/sec/cm2 p/sec/cm2
5
4.32
Cu
0
21.17
7.06E+05 1.24E+03 1.40E+03 2.39E+02
1.44E+04
11
1.56E-05
5
4.32
Cu
0
21.17
7.12E+05 1.45E+03 5.90E+03 2.41E+02
1.46E+04
18
2.53E-05
5
4.32
Cu
0
21.17
9.11E+05 1.19E+03 6.06E+03 3.09E+02
1.49E+04
10
1.10E-05
5
4.32
Cu
0
21.17
8.25E+05 1.09E+03 1.23E+03 2.79E+02
1.52E+04
13
1.58E-05
5
4.32
Cu
0
21.17
5.40E+05 8.96E+02 2.57E+03 1.83E+02
1.54E+04
10
1.85E-05
5
4.32
Cu
0
21.17
1.00E+06 7.90E+02 1.30E+03 3.39E+02
1.57E+04
3
3.00E-06
5
4.32
Cu
0
21.17
1.00E+06 8.61E+02 2.14E+03 3.39E+02
1.61E+04
8
8.00E-06
0
1
Cu
0
21.17
2.25E+05 7.24E+02 8.30E+02 7.62E+01
1.62E+04
16
7.11E-05
0
1
Cu
0
21.17
2.59E+05 9.41E+02 1.07E+03 8.77E+01
1.62E+04
15
5.79E-05
0
1
Cu
0
21.17
2.08E+05 9.35E+02 1.06E+03 7.05E+01
1.63E+04
16
7.69E-05
0
1
Cu
0
21.17
2.64E+05 8.72E+02 1.04E+03 8.94E+01
1.64E+04
16
6.06E-05
0
1
Cu
0
21.17
3.41E+05 6.83E+02 1.26E+03 1.16E+02
1.65E+04
11
3.23E-05
0
1
Cu
0
21.17
3.59E+05 8.31E+02 1.03E+03 1.22E+02
1.66E+04
13
3.62E-05
0
1
Cu
0
21.17
3.95E+05 1.51E+03 1.90E+03 1.34E+02
1.68E+04
13
3.29E-05
0
1
Cu
0
21.17
3.78E+05 1.64E+03 1.90E+03 1.28E+02
1.69E+04
13
3.44E-05
0
1
Cu
0
21.17
6.27E+05 1.59E+03 1.89E+03 2.12E+02
1.71E+04
13
2.07E-05
5
4.32
Ar
0
9.74
4.89E+05 1.35E+03 1.49E+03 7.62E+01
1.72E+04
13
2.66E-05
5
4.32
Ar
0
9.74
7.11E+05 1.43E+03 3.35E+03 1.11E+02
1.73E+04
14
1.97E-05
0.50
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0.62
0.65
0.70
0.75
0.80
0.85
0.90
0.95
0.95
0.54
0.45
p/cm2
rads(Si)
rads(Si)
cm2/circuit
28
69
//
1
39.5
3.55
70
//
1
39.5
2.55
71
//
1
39.5
1.55
Run
Design
DUT
Tb
(Vacuum)
Vin
(°C)
(V)
74
//
1
39.5
7.05
76
//
1
39.5
8.05
77
//
1
39.5
9.05
78
//
1
39.5
10.05
79
//
1
39.5
5.40
80
//
1
39.5
4.55
81
//
1
39.5
3.55
82
//
1
39.5
6.20
83
//
1
39.5
7.05
84
//
1
39.5
8.05
85
//
1
39.5
9.05
86
//
1
39.5
10.05
87
//
1
39.5
5.40
88
//
1
39.5
4.55
89
//
1
39.5
3.55
90
//
1
39.5
6.20
0.35
5
4.32
Ar
0
9.74
1.00E+06 2.94E+03 3.34E+03 1.56E+02
1.75E+04
10
1.00E-05
5
4.32
Ar
0
9.74
1.00E+06 2.88E+03 3.45E+03 1.56E+02
1.76E+04
6
6.00E-06
5
4.32
Ar
0
9.74
1.00E+06 1.87E+03 4.63E+03 1.56E+02
1.78E+04
4
4.00E-06
Inv.
Input
Bias
Vout
Trig Vout
Ion
Tilt
Angle
Effective Effective
LET
Fluence
Average Maximum
TID
TID (Run)
Flux
Flux
(Cumulative)
#SET
SET CrossSection
(V)
(V)
(V)
degrees
MeV.cm2/
mg
p/sec/cm2 p/sec/cm2
0
1
Ar
0
9.74
3.02E+05 2.28E+03 3.11E+03 4.71E+01
1.80E+04
14
4.64E-05
0
1
Ar
0
9.74
7.01E+05 2.32E+03 6.02E+03 1.09E+02
1.82E+04
7
1.10E-05
0
1
Ar
0
9.74
1.00E+06 2.87E+03 3.21E+03 1.56E+02
1.84E+04
20
2.00E-05
0
1
Ar
0
9.74
1.00E+06 3.00E+03 3.63E+03 1.56E+02
1.85E+04
5
5.00E-06
5
4.32
Si
0
6.09
1.00E+06 1.79E+03 2.48E+03 9.74E+01
1.86E+04
2
2.00E-06
5
4.32
Si
0
6.09
1.00E+06 1.71E+03 2.62E+03 9.74E+01
1.87E+04
0
1.00E-06
5
4.32
Si
0
6.09
1.00E+06 1.11E+03 1.65E+03 9.74E+01
1.88E+04
1
1.00E-06
0
1
Si
0
6.09
3.81E+05 1.06E+03 1.44E+03 3.71E+01
1.88E+04
10
2.62E-05
0
1
Si
0
6.09
1.00E+06 1.28E+03 3.21E+03 9.74E+01
1.89E+04
7
7.00E-06
0
1
Si
0
6.09
1.00E+06 2.12E+03 3.33E+03 9.74E+01
1.90E+04
2
2.00E-06
0
1
Si
0
6.09
1.00E+06 2.59E+03 4.33E+03 9.74E+01
1.91E+04
3
3.00E-06
0
1
Si
0
6.09
1.00E+06 2.33E+03 3.30E+03 9.74E+01
1.92E+04
0
1.00E-06
5
4.32
Si
0
6.09
1.00E+06 2.74E+03 3.37E+03 9.74E+01
1.93E+04
1
1.00E-06
5
4.32
Si
0
6.09
1.00E+06 2.53E+03 3.42E+03 9.74E+01
1.94E+04
1
1.00E-06
5
4.32
Si
0
6.09
1.00E+06 2.84E+03 3.55E+03 9.74E+01
1.95E+04
1
1.00E-06
0
1
Si
0
6.09
1.00E+06 2.30E+03 3.35E+03 9.74E+01
1.96E+04
13
1.30E-05
0.25
0.15
0.70
0.80
0.90
1.00
0.54
0.45
0.35
0.62
0.70
0.80
0.90
1.00
0.54
0.45
0.35
0.62
p/cm2
rads(Si)
rads(Si)
cm2/circuit
29
91
//
1
39.5
7.05
92
//
1
39.5
8.05
94
//
1
39.5
10.05
95
//
1
39.5
5.40
96
//
1
39.5
5.40
Run
Design
DUT
Tb
(Vacuum)
Vin
(°C)
(V)
99
//
1
39.5
3.05
100
//
1
39.5
2.05
101
//
1
39.5
1.05
102
//
1
39.5
0.55
103
//
1
39.5
6.20
104
//
1
39.5
6.55
105
//
1
39.5
7.05
106
//
1
39.5
8.05
107
//
1
39.5
9.05
108
//
1
39.5
10.05
109
//
1
39.5
5.40
110
//
1
39.5
4.05
111
//
1
39.5
3.05
112
//
1
39.5
2.05
113
//
1
39.5
1.05
0.70
0
1
Si
0
6.09
1.00E+06 2.10E+03 3.21E+03 9.74E+01
1.97E+04
3
3.00E-06
0
1
Si
0
6.09
1.00E+06 4.49E+03 5.98E+03 9.74E+01
1.98E+04
1
1.00E-06
0
1
Si
-0.3
6.09
1.00E+06 4.90E+03 7.64E+03 9.74E+01
1.99E+04
0
1.00E-06
5
4
Xe
-0.3
58.78
1.77E+05 1.01E+04 1.06E+04 1.66E+02
2.01E+04
0
5.65E-06
5
4
Xe
-0.3
58.78
2.23E+05 1.03E+03 1.16E+03 2.10E+02
2.03E+04
25
1.12E-04
Inv.
Input
Bias
Vout
Trig Vout
Ion
Tilt
Angle
Effective Effective
LET
Fluence
Average Maximum
TID
TID (Run)
Flux
Flux
(Cumulative)
#SET
SET CrossSection
(V)
(V)
(V)
degrees
MeV.cm2/
mg
p/sec/cm2 p/sec/cm2
5
4
Xe
-0.3
58.78
4.09E+05 1.09E+03 3.26E+03 3.85E+02
2.14E+04
29
7.09E-05
5
4
Xe
-0.3
58.78
3.77E+05 1.05E+03 3.48E+03 3.55E+02
2.18E+04
16
4.24E-05
5
4
Xe
-0.3
58.78
5.61E+05 9.56E+02 1.11E+03 5.28E+02
2.23E+04
11
1.96E-05
5
4
Xe
-0.3
58.78
5.00E+05 1.05E+03 3.43E+03 4.70E+02
2.27E+04
22
4.40E-05
0
1
Xe
-0.3
58.78
1.52E+05 9.02E+02 9.89E+02 1.43E+02
2.29E+04
63
4.14E-04
0
1
Xe
-0.3
58.78
8.45E+04 9.66E+02 1.05E+03 7.95E+01
2.30E+04
23
2.72E-04
0
1
Xe
-0.3
58.78
4.45E+05 9.47E+02 1.06E+03 4.19E+02
2.34E+04
111
2.49E-04
0
1
Xe
-0.3
58.78
2.40E+05 9.03E+02 9.90E+02 2.26E+02
2.36E+04
51
2.13E-04
0
1
Xe
-0.3
58.78
4.69E+05 9.09E+02 3.09E+03 4.41E+02
2.41E+04
57
1.22E-04
0
1
Xe
-0.3
58.78
5.50E+05 8.02E+02 9.26E+02 5.17E+02
2.46E+04
50
9.09E-05
5
4
Ar
-0.3
9.74
7.05E+05 1.68E+03 2.14E+03 1.10E+02
2.47E+04
21
2.98E-05
5
4
Ar
-0.3
9.74
1.46E+06 1.77E+03 2.14E+03 2.28E+02
2.49E+04
21
1.44E-05
5
4
Ar
-0.3
9.74
1.00E+06 1.59E+03 3.05E+03 1.56E+02
2.51E+04
9
9.00E-06
5
4
Ar
-0.3
9.74
1.00E+06 1.63E+03 4.94E+03 1.56E+02
2.52E+04
2
2.00E-06
5
4
Ar
-0.3
9.74
1.00E+06 1.67E+03 3.37E+03 1.56E+02
2.54E+04
0
1.00E-06
0.80
0.90
1.00
0.54
0.40
0.30
0.20
0.10
0.05
0.62
0.65
0.70
0.80
0.90
1.00
0.54
0.40
0.30
0.20
p/cm2
rads(Si)
rads(Si)
cm2/circuit
30
114
//
1
39.5
6.20
115
//
1
39.5
7.05
116
//
1
42
8.05
117
//
1
42
9.05
118
//
1
42
10.05
119
//
1
107
10.05
Run
Design
DUT
Tb
(Vacuum)
Vin
(°C)
(V)
122
With 0.1uF
Cout
2
39.5
5.40
123
//
2
39.5
5.40
124
//
2
39.5
5.40
127
//
2
39.5
5.40
128
//
2
39.5
1.05
129
//
2
97
10.05
130
//
2
97
10.05
0.10
0
4
Ar
-0.3
9.74
4.91E+05 1.76E+03 5.34E+03 7.65E+01
2.55E+04
20
4.07E-05
0
1
Ar
-0.3
9.74
1.00E+06 1.60E+03 2.06E+03 1.56E+02
2.56E+04
30
3.00E-05
0
1
Ar
-0.3
9.74
8.99E+05 1.57E+03 2.12E+03 1.40E+02
2.58E+04
22
2.45E-05
0
1
Ar
-0.3
9.74
1.00E+06 1.59E+03 3.66E+03 1.56E+02
2.59E+04
11
1.10E-05
0
1
Ar
-0.3
9.74
1.00E+06 1.59E+03 3.25E+03 1.56E+02
2.61E+04
0
1.00E-06
0
1
Xe
-0.3
58.78
1.00E+07 1.49E+04 1.69E+04 9.40E+03
3.55E+04
1338
1.34E-04
Inv.
Input
Bias
Vout
Trig Vout
Ion
Tilt
Angle
Effective Effective
LET
Fluence
Average Maximum
TID
TID (Run)
Flux
Flux
(Cumulative)
#SET
SET CrossSection
(V)
(V)
(V)
degrees
MeV.cm2/
mg
p/sec/cm2 p/sec/cm2
5
4
Xe
1.6
58.8
1.05E+06 1.63E+03 4.48E+03 9.88E+02
5.56E+04
0
9.52E-07
5
4
Xe
1.6
58.8
3.91E+06 4.80E+04 8.16E+04 3.68E+03
5.93E+04
0
2.56E-07
5
4
Xe
1.6
58.8
2.96E+07 8.79E+04 9.38E+04 2.78E+04
8.72E+04
0
3.38E-08
5
4
Xe
0
58.78
1.01E+07 9.11E+04 9.64E+04 9.50E+03
9.67E+04
0
9.90E-08
5
1
Xe
0
58.78
1.01E+07 9.13E+04 9.88E+04 9.50E+03
1.06E+05
0
9.90E-08
0
1
Xe
0
58.78
1.21E+07 9.43E+04 1.02E+05 1.14E+04
1.18E+05
0
8.26E-08
0
1
Xe
60
117.56
1.00E+07 8.03E+04 1.02E+05 1.88E+04
1.36E+05
0
1.00E-07
0.62
0.70
0.80
0.90
1.00
0.50
0.54
0.54
0.54
0.54
0.10
1.00
p/cm2
rads(Si)
rads(Si)
cm2/circuit
*Tb is the temperature sensed by the transistor on the board (as shown in Fig. 5)
3ft BNC cable (120pF)
Energy Cocktail
10MeV/nucleon
31
Table 3: Raw Data for the Heavy-Ion Beam Runs (VOS Board)
Run
Design
DUT
Tb
(Vacuum)
Vin
(°C)
(V)
131
With
Cout=22nF
3
37
-0.55
132
//
3
37
-0.55
133
//
3
37
-0.55
134
//
3
37
-1.05
135
//
3
37
-1.55
136
//
3
37
-2.05
137
//
3
37
0.55
138
//
3
37
0.55
139
//
3
37
1.05
140
//
3
37
1.55
Inverting
Input Bias
Vout
Trig
Vout
(V)
(V)
(V)
-0.050
-0.050
-0.050
-0.100
-0.150
-0.200
0.050
0.050
0.100
0.150
Ion
Tilt
Angle
Effective
LET
Effective
Fluence
Average
Flux
Maximum
Flux
TID
(Run)
TID
(Cumulative)
degrees
MeV.cm2/mg
p/cm2
p/sec/cm2
p/sec/cm2
rads(Si)
rads(Si)
1.72E+04
5.69E+04
9.40E+03
46
3.45E+04
5.90E+04
7.06E+03
45
1.07E+03
2.25E+03
9.40E+02
8
1.29E+03
6.97E+03
9.40E+02
2
2.01E+03
7.11E+03
9.40E+02
8
1.77E+03
1.70E+03
5.37E+00
5
4.65E+03
7.36E+03
9.40E+02
0
1.23E+03
2.16E+03
9.40E+02
0
1.95E+03
5.63E+03
9.40E+02
0
2.03E+03
6.32E+03
9.40E+02
0
12
11
Xe
0
58.78
1.00E+07
12
11
Xe
0
58.78
7.51E+06
12
11
Xe
0
58.78
1.00E+06
12
11
Xe
0
58.78
1.00E+06
12
11
Xe
0
58.78
1.00E+06
12
11
Xe
0
58.78
5.71E+03
0
1
Xe
0
58.78
1.00E+06
0
1
Xe
0
58.78
1.00E+06
0
1
Xe
0
58.78
1.00E+06
0
1
Xe
0
58.78
1.00E+06
1.72E+04
3.45E+04
1.07E+03
1.29E+03
2.01E+03
1.77E+03
4.65E+03
1.23E+03
1.95E+03
2.03E+03
#SET
SET
CrossSection
cm2/circuit
4.60E-06
5.99E-06
8.00E-06
2.00E-06
8.00E-06
8.76E-04
1.00E-06
1.00E-06
1.00E-06
1.00E-06
32
141
//
3
37
1.05
142
//
3
37
1.55
143
//
3
37
1.55
144
//
3
37
2.05
145
//
3
37
-2.05
146
//
3
37
-1.55
147
//
3
37
-0.25
148
//
3
37
-0.25
149
//
3
37
-0.55
150
//
3
37
-1.55
Run
Design
DUT
Tb
(Vacuum)
Vin
(°C)
(V)
153
//
3
37
-0.55
154
//
3
37
-1.05
155
//
3
37
-1.55
156
//
3
37
-2.05
157
//
3
37
-0.25
158
//
3
37
-0.55
159
//
3
37
-1.05
160
//
3
37
-1.55
161
//
3
37
-1.55
162
//
3
37
0.25
0.100
0.150
0.150
0.200
-0.200
-0.150
-0.020
-0.020
-0.050
-0.150
Inv. Input
Bias
(V)
-0.050
-0.100
-0.150
-0.200
-0.020
-0.050
-0.100
-0.150
-0.150
0.020
0
1
Xe
0
58.78
1.00E+06
0
1
Xe
0
58.78
1.00E+06
0
1
Xe
0
58.78
1.00E+06
0
1
Xe
0
58.78
1.00E+06
12
11
Xe
0
58.78
1.00E+06
12
11
Xe
0
58.78
1.00E+06
12
11
Xe
0
58.78
1.00E+06
12
11
Ag
0
48.15
1.00E+06
12
11
Ag
0
48.15
1.00E+06
12
11
Ag
0
48.15
1.00E+06
Vout
Trig
Vout
Ion
Tilt
Angle
Effective
LET
Effective
Fluence
(V)
(V)
degrees
MeV.cm2/mg
p/cm2
12
11
Ag
0
48.15
6.18E+05
12
11
Ag
0
48.15
7.21E+05
12
11
Ag
0
48.15
8.10E+05
12
11
Ag
0
48.15
1.00E+06
12
11
Xe
-2.7
58.85
1.00E+06
12
11
Xe
-2.7
58.85
2.01E+05
12
11
Xe
-2.7
58.85
4.02E+05
12
11
Xe
-2.7
58.85
2.83E+05
12
11
Xe
-2.7
58.85
3.64E+05
0
2
Xe
-2.7
58.85
7.77E+04
1.50E+03
1.50E+03
1.92E+03
9.40E+02
0
1.77E+03
1.93E+03
9.40E+02
0
6.52E+03
7.33E+03
9.40E+02
0
1.30E+03
2.26E+03
9.40E+02
0
1.77E+03
2.14E+03
9.40E+02
4
1.85E+03
2.10E+03
9.40E+02
4
1.82E+03
2.11E+03
9.40E+02
7
1.01E+03
1.68E+03
7.70E+02
0
1.06E+03
1.23E+03
7.70E+02
0
1.33E+03
3.00E+03
7.70E+02
0
Average
Flux
Maximum
Flux
TID
(Run)
TID
(Cumulative)
#SET
p/sec/cm2
p/sec/cm2
rads(Si)
rads(Si)
1.34E+03
2.65E+03
4.76E+02
20
1.39E+03
3.76E+03
5.55E+02
20
4.01E+03
4.45E+03
6.24E+02
20
5.35E+03
1.13E+04
7.70E+02
28
3.37E+03
3.61E+03
9.42E+02
230
3.75E+03
3.93E+03
1.89E+02
23
3.81E+03
4.05E+03
3.79E+02
20
3.79E+03
4.00E+03
2.66E+02
20
3.75E+03
3.97E+03
3.43E+02
26
3.57E+03
3.69E+03
7.32E+01
93
1.77E+03
6.52E+03
1.30E+03
1.77E+03
1.85E+03
1.82E+03
1.01E+03
1.06E+03
1.33E+03
1.34E+03
1.39E+03
4.01E+03
5.35E+03
3.37E+03
3.75E+03
3.81E+03
3.79E+03
3.75E+03
3.57E+03
1.00E-06
1.00E-06
1.00E-06
1.00E-06
4.00E-06
4.00E-06
7.00E-06
1.00E-06
1.00E-06
1.00E-06
SET
CrossSection
cm2/circuit
3.24E-05
2.77E-05
2.47E-05
2.80E-05
2.30E-04
1.14E-04
4.98E-05
7.07E-05
7.14E-05
1.20E-03
33
163
//
3
37
0.25
164
//
3
37
0.55
165
//
3
37
1.05
166
//
3
37
1.55
167
//
3
37
2.05
168
//
3
42
0.25
169
//
3
42
0.55
170
//
3
42
1.05
171
//
3
42
1.55
172
//
3
42
2.05
0.020
0
2
Xe
-2.7
58.85
1.87E+05
0
2
Xe
-2.7
58.85
1.81E+05
0
2
Xe
-2.7
58.85
3.98E+05
0
2
Xe
-2.7
58.85
2.17E+05
0
2
Xe
-2.7
58.85
3.37E+05
0
2
Ag
-2.7
48.15
3.65E+05
0
2
Ag
-2.7
48.15
4.84E+05
0
2
Ag
-2.7
48.15
5.89E+05
0.150
0
2
Ag
-2.7
48.15
5.51E+05
0.200
0
2
Ag
-2.7
48.15
7.62E+05
0.050
0.100
0.150
0.200
0.020
0.050
0.100
3.51E+03
3.53E+03
3.50E+03
3.54E+03
3.48E+03
4.47E+03
4.44E+03
4.25E+03
4.22E+03
4.23E+03
3.51E+03
3.69E+03
1.76E+02
62
3.53E+03
3.69E+03
1.70E+02
28
3.50E+03
3.68E+03
3.75E+02
52
3.54E+03
3.69E+03
2.04E+02
23
3.48E+03
3.65E+03
3.17E+02
22
4.47E+03
7.35E+03
2.81E+02
28
4.44E+03
7.99E+03
3.73E+02
20
4.25E+03
4.48E+03
4.54E+02
22
4.22E+03
4.43E+03
4.24E+02
20
4.23E+03
4.59E+03
5.87E+02
22
3.32E-04
1.55E-04
1.31E-04
1.06E-04
6.53E-05
7.67E-05
4.13E-05
3.74E-05
3.63E-05
2.89E-05
*Tb is the temperature sensed by the transistor on the board (as shown in Fig. 6)
34
References:
[1] RH1011M DataSheet: http://www.linear.com/product/RH1011
[2] LT1011 Datasheet: http://www.linear.com/product/LT1011
[3] S. Rezgui et al., IEEE TNS Papers, NO. 6, Dec. 2007- 2011.
[4] R. Koga et al., “Single Event Upset (SEU) Sensitivity Dependence of Linear Integrated Circuits (ICs) on Bias
Conditions”, IEEE TNS, Vol. 44, NO. 6, Dec. 1997.
[5] LTSpice: http://www.linear.com/designtools/software/#LTspice
[6] RH1011M Spec.: http://cds.linear.com/docs/Spec%20Notice/RH1011_05-08-5012_SPEC_REV.M.pdf
35