Catálogo Fontes de Alimentação (em PDF)

Switch-Mode and Uninterruptible Power Supplies,
Electronic Fuses
Catalogue 2013
Power Supply
The World of Industrial Connectivity
As experienced experts we support our customers and partners around the world
with products, solutions and services in the industrial environment of power, signal
and data. Immerse yourself in our world of Industrial Connectivity.
Let’s connect.
DATA
Automation Device
Signal or power electronics
JACKPAC ®
IP 68
PCB terminals
Media
converter
Switches
FrontCom ® Micro
Service interface
Power supplies
IE-LINE
plug-in connectors
Active sensoractuator-interfaces
PCB connectors
IE-LINE
Connection components
Surge
protection
Terminal rail
outlet
Fieldbus distributors
Electronics
housings
Signal
converters
Solid-state
relays
Passive sensor-actuatorinterfacesand cables
Relay modules
SIGNAL
Modular Terminal Blocks
POWER
Cable glands
Interface Units Surge protection for
Instrumentation &
Control equipment
Stud terminals
Cabinet
FieldPower®
Enclosures and accessories
Heavy-duty
connectors
Tools and identification systems
Cutting tools
Stripping tools
Crimping tools
More tools
Software
Printer
Markers
Dear Customers,
The PDF versions of our catalogues offer practical additional functions,
helping you to find your way around our product range and simplifying
the ordering process.
In addition to the catalogue, the PDF also contains:
• Internal page links
• Links to the online catalogue
Try it out for yourself. Click the order number to obtain more detailed
information and close-up images via you web browser. The links in the
PDF file also enable you to go directly to the next desired catalogue page.
Further Weidmüller product catalogues can be accessed by
clicking the following:
4.5
PLC-system cabling
6
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
32758 Detmold, Germany
T +49 5231 14-0
F +49 5231 14-292083
[email protected]
www.weidmueller.com
Order number: 1327330000/06/2012/SMDM
PLC-system cabling
Connectivity and electrical installation
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
32758 Detmold, Germany
T +49 5231 14-0
F +49 5231 14-292083
[email protected]
www.weidmueller.com
Order number: 1327490000/11/2012/SMDM
Power supply
Switched-mode and uninterruptible power supplies,
and electronic fuses
Catalogue 2013
Let’s connect.
Digital Signal Processing
7
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
32758 Detmold, Germany
T +49 5231 14-0
F +49 5231 14-292083
[email protected]
www.weidmueller.com
Order number: 1366860000/11/2012/SMDM
Weidmüller – Partner in Industrial Connectivity
9
Industrial Ethernet
Catalogue 2013
Let’s connect.
As experienced experts we support our customers and partners around the world
Markers, with
printers,
software
products, solutions
and services in the industrial environment of power,
signal and data. We are at home in their industries and markets and know the
Cataloguetechnological
2013/2014
challenges of tomorrow. We are therefore continuously developing
innovative, sustainable and useful solutions for their individual needs. Together we
Let’s connect.
set standards in Industrial Connectivity.
Order number: 1366810000/03/2013/SMDM
Power supply
Catalogue 2013
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
32758 Detmold, Germany
T +49 5231 14-0
F +49 5231 14-292083
[email protected]
www.weidmueller.com
Order number: 1327250000/04/2012/SMDM
Weidmüller – Partner in Industrial Connectivity
As experienced experts we support our customers and partners around the world
Tools with
products, solutions and services in the industrial environment of power,
signal and data. We are at home in their industries and markets and know the
Catalogue
2013
technological
challenges of tomorrow. We are therefore continuously developing
innovative, sustainable and useful solutions for their individual needs. Together we
Let’s connect.
set standards in Industrial Connectivity.
Catalogue 2012/2013
Catalogue 2013
Surge protection
Surge protection
Weidmüller – Partner in Industrial Connectivity
As experienced experts we support our customers and partners around the world
PLC-interface
units,
with products,
solutions front
and servicesadapters
in the industrial environment of power,
signal and data. We are at home in their industries and markets and know the
and prefabricated
cables
technological challenges
of tomorrow. We are therefore continuously developing
sustainable and useful solutions for their individual needs. Together we
Cataloguesetinnovative,
2012/2013
standards in Industrial Connectivity.
Let’s connect.
Tools
Weidmüller – Partner in Industrial Connectivity
As experienced experts we support our customers and partners around the world
Surge protection
devices
with products, solutions
and services in the industrial environment of power,
signal and data. We are at home in their industries and markets and know the
Cataloguetechnological
2013challenges of tomorrow. We are therefore continuously developing
innovative, sustainable and useful solutions for their individual needs. Together we
Let’s connect.
set standards in Industrial Connectivity.
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
32758 Detmold, Germany
T +49 5231 14-0
F +49 5231 14-292083
[email protected]
www.weidmueller.com
Order number: 1327190000/07/2012/SMDM
4.3
Industrial Ethernet
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
32758 Detmold, Germany
T +49 5231 14-0
F +49 5231 14-292083
[email protected]
www.weidmueller.com
Order number: 1381510000/01/2013/SMDM
Catalogue 2013
4.4
ound the world
t of power,
nd know the
sly developing
eds. Together we
Analogue signal conditioning
Weidmüller – Partner in Industrial Connectivity
As experienced experts we support our customers and partners around the world
Relay Modules
and
Solid-State
Relays
with products,
solutions
and services in the industrial
environment of power,
signal and data. We are at home in their industries and markets and know the
challenges of tomorrow. We are therefore continuously developing
Cataloguetechnological
2012/2013
innovative, sustainable and useful solutions for their individual needs. Together we
set standards in Industrial Connectivity.
Let’s connect.
Markers, printers, software
Catalogue 2013
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
32758 Detmold, Germany
T +49 5231 14-0
F +49 5231 14-292083
[email protected]
www.weidmueller.com
4.2
Catalogue 2012/2013
OMNIMATE – device connectivity
Weidmüller – Partner in Industrial Connectivity
As experienced experts we support our customers and partners around the world
Signal converters,
trip
amplifiers
and process
meters
with products, solutions
and services
in the industrial environment
of power,
signal and data. We are at home in their industries and markets and know the
Cataloguetechnological
2012/2013
challenges of tomorrow. We are therefore continuously developing
innovative, sustainable and useful solutions for their individual needs. Together we
Let’s connect.
set standards in Industrial Connectivity.
Industrial marking system
Catalogue 2013
OMNIMATE – device connectivity
Modular terminal blocks
Catalogue 2012/2013
Connectivity
Order number: 1282250000/03/2012/SMDM
Order number: 1366910000/11/2012/SMDM
4.1
Digital Signal Processing
Weidmüller – Partner in Industrial Connectivity
As experienced experts we support our customers and partners around the world
PCB terminal
blocks,
with products,
solutions andPCB
services inconnectors,
the industrial environmentpanel
of power,
signal and data. We are at home in their industries and markets and know the
feedthrough
terminal
blocks
and
electronics
technological
challenges of tomorrow.
We are
therefore
continuously developing housings
sustainable and useful solutions for their individual needs. Together we
Cataloguesetinnovative,
2013
standards in Industrial Connectivity.
Let’s connect.
Catalogue 2012/2013
2
Catalogue 2013/2014
Weidmüller – Partner in Industrial Connectivity
As experienced experts we support our customers and partners around the world
Modular
terminal
blocks
with products,
solutions and services
in the industrial environment of power,
signal and data. We are at home in their industries and markets and know the
Catalogue
technological 2012/2013
challenges of tomorrow. We are therefore continuously developing
sustainable and useful solutions for their individual needs. Together we
Let’s setinnovative,
connect.
standards in Industrial Connectivity.
Analogue signal conditioning
1
he world
ower,
ow the
veloping
ogether we
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
32758 Detmold, Germany
T +49 5231 14-0
F +49 5231 14-292083
[email protected]
www.weidmueller.com
Order number: 1381580000/11/2012/SMDM
Industrial data communication
Switch-Mode and
Uninterruptible Power Supplies,
Electronic Fuses
Appendix
Contents
Switch-Mode and Uninterruptible Power Supplies, Electronic Fuses
Catalogue 4.3
Switch-mode power supplies
A
Uninterruptible power supplies (UPS)
B
Fuse protection for 24 V DC circuits
C
Unregulated power supplies
D
IP 65 switched-mode power supply / Electrical cabinet socket outlet
E
Weidmüller Solutions & Service
V
W
Glossary/Technical appendix
Index
1366860000 – 2013
X
Index Type / Index Order No.
Addresses worldwide
I
Product overview
Power supplies – Overview
II
connectPower 1ph PRO-M
connectPower 3ph PRO-M
connectPower PRO-M Extension modules
•Single-phase switched-mode power supply
modules, very slim design
•High degree of efficiency
•Power category 70...1,000 W
•Up to five devices can be connected in parallel
without a diode module
•International approvals
•3-phase switched-mode power supply modules,
very slim design
•High degree of efficiency
•Power category 120...1,000 W
•Up to five devices can be connected in parallel
without a diode module
•International approvals
•Capacity module for increasing the peak current
•Diode modules for redundant construction •Relay module for monitoring the output voltage
connectPower PRO-M Application solutions
connectPower 1ph PRO-H
connectPower PRO-H Multi-phase
•Wide-range input
85...264 V AC
80...430 V DC
•Alarm relay •Metal snap-on foot •International approvals
•Single-phase switch-mode power supplies
•High MTBF values
•Cl. I Div. 2 + ATEX
•Performance class: 70 to 600 W •Output: 12, 24, 36 and 48 V DC
•Multi-phase switch-mode power supplies
•85...132 / 187...550 V AC
•UL approval
•Performance class: 180 to 600 W
connectPower PRO-H Redundancy modules
connectPower 1ph ECOLINE
connectPower 3ph ECOLINE
•15 A or 25 A
•100 % load sharing
•Remote On/Off
•International approvals
•Cl. I Div. 2 + ATEX
•Single-phase switched-mode power supply
modules
•Compact form
•Metal housing
•Power category 70…1,000 W
•International approvals
•3-phase switched-mode power supply modules
•Compact form
•Metal housing
•Power category 120…1,000 W
•International approvals
1366860000 – 2013
Product overview
connectPower ECOLINE Diode modules
connectPower 1ph INSTAPOWER
connectPower 1ph WAVEPOWER
•Diode module for 100 % decoupling of
switched-mode power supply modules
•Optimum doubling of output power
•Redundancy operation
•Up to 40 A output current can be set
•International approvals
•Single-phase switched-mode power supply
modules for the distribution board
•Compact form
•Power category 24 and 48 W
•Universal input and output voltage 5…48 V
•International approvals
•Single-phase switched-mode power supply unit
•Slim design 22.5 mm
•Power category 12 W
•International approvals
connectPower 1ph
connectPower 3ph
connectPower DC/DC converters
•Single-phase switched-mode power supply
modules
•Metal housing
•Power category 55 W and 160 W
•Universal input and output voltage 5…48 V
•International approvals
•300-watt performance category, with active PFC
•3-phase switched-mode power supply modules
•Metal housing
•Up to 5 devices can be directly connected in
parallel
•Professional display and processing of all relevant
signal states
•International approvals
•Compact form
•Metal housing
•Universal input and output voltage of 5 V to 48 V
•International approvals
connectPower UPS control unit
connectPower battery module
connectPower buffer module
•Two 24 V models in 10 A/20 A and 40 A
•Temperature-compensated charging feature,
for a long battery life
•Integrated battery diagnostics including
continuous availability test
•Status relay and additional transistor outputs for
remote monitoring
•Convenient LED displays for easy error analysis
•Maintenance-free, lead-acid batteries from
1.3 Ah to 17 Ah
•Integrated temperature sensor for optimal battery
charging
•Integrated fuse for reliable activation
•Support capacity up to 40 A / 30 min or
10 A / 90 min
•Robust metal housing for wall mounting
•Maintenance-free UPS on a capacitor basis, with
a capacity to support 20 A / 200 ms
•Parallel switching to increase the output current
or support time
•Status notification via LED and relay contact
1366860000 – 2013
III
Product overview
Power supplies – Overview
IV
compactPower 1ph unregulated power supplies
compactPower 3ph unregulated power supplies
WAVEGUARD
•Single-phase unregulated power supplies
•Compact form
•Standard voltage ~230/400 V to
IEC38 +/– 15 V tap
•Reliable short-circuit and overload protection
•3-phase unregulated power supplies
•Compact form
•Nominal voltage to IEC38 +/- 5 V tap
•Reliable short-circuit and overload protection
•Electronic fusing
•Visual fault indication and potential-free contact
•Reset input
•Compact form
FieldPower® IP 65 switched-mode power supply
Electrical cabinet socket outlet
•3-phase switch-mode power supply unit, 24 V / 5 A
on FieldPower® power bus, 5 x 2.5...6 mm²
•Integrated input fuse
•Decentralised 24 V DC generation and distribution
for widely distributed facilities
•Reduced voltage drops in DC systems
•Increased energy efficiency because of minimal
transmission losses
•Simple installation in electrical cabinet
•TS 35 module can be rail mounted
•VDE mark of conformity
•Two-pole with earthing contact
1366860000 – 2013
1366860000 – 2013
V
Product overview
Power supplies – Selection
PRO-M
Mains
1ph
Input voltage
85...265 V AC,
80...370 V DC
Input frequency
50 / 60 Hz
CE, cURus, cULus;
C-Tick, GL
Output voltage
24 V
Output current
Order No.
Page
3A
5A
7,5 A
10 A
20 A
8951330000
8951340000
8951350000
8951360000
8951370000
A.5
A.5
A.6
A.6
A.7
PRO-M expansion modules
Mains
1ph
Input voltage
85...265 V AC,
80...430 V DC,
Input frequency
50 / 60 Hz
CE, cURus*, cULus;
C-Tick, GL
Output voltage
Diode module
Diode module
Output current
20 A
40 A
1222210000
A.10
Order No.
Page
Relay module
Capacity module
1222220000
1222230000
1222240000
A.10
A.11
A.12
PRO-H
Mains
1ph
Input voltage
85...264 V AC,
85...132 / 187...265 V AC
(Depending on model)
Input frequency
50 / 60 Hz
CE; UL; CSA; Class I Div.2;
ATEX Zone 2
(Depending on model)
Output voltage
12 V
12 V
24 V
24 V
24 V
24 V
Output current
6A
12 A
3.8 A
3.8 A (CL 2)
7.5 A
15 A
1105430000
1105440000
1105790000
1194410000
1105810000
1105820000
A.17
A.17
A.18
A.18
A.19
A.19
Order No.
Page
VI
Similar to illustration
1366860000 – 2013
Product overview
PRO-M
Mains
1ph / 3ph
Input voltage
85...265 V AC,
120...300 V DC
Input frequency
50 / 60 Hz
CE, cURus, cULus; C-Tick
Output voltage
1ph / 24 V
Output current
40 A
5A
10 A
20 A
40 A
8951380000
8951390000
8951400000
8951410000
8951420000
A.7
A.8
A.8
A.9
A.9
Order No.
Page
3ph / 24 V
PRO-M application solutions
Mains
1ph
Input voltage
85...265 V AC,
80...430 V DC,
Input frequency
50 / 60 Hz
CE, cURus*, cULus;
C-Tick, GL
Output voltage
24 V
Output current
10 A
Order No.
1165480010
Page
A.15
PRO-H
Mains
1ph
Input voltage
85...264 V AC,
85...132 / 187...265 V AC
(Depending on model)
Input frequency
50 / 60 Hz
CE; UL; CSA; Class I Div.2;
ATEX Zone 2
(Depending on model)
Similar to illustration
Similar to illustration
Similar to illustration
Output voltage
24 V
36 V
48 V
48 V
48 V
48 V
Output current
25 A
16.5 A
2A
4A
7.5 A
12.5 A
1105840000
1194430000
1194420000
1105850000
1105860000
1105870000
A.20
A.20
A.21
A.21
A.22
A.22
Order No.
Page
1366860000 – 2013
VII
Product overview
Power supplies – Selection
PRO-H redundancy module
24 V DC
CE, UL, UR, Class I Div.2;
ATEX
Output voltage
24 V
24 V
Output current
15 A
20 A
1105880000
1105890000
A.25
A.25
Order No.
Page
INSTAPOWER
Mains
1ph
Input voltage
85...265 V AC,
120...300 V DC,
110...370 V DC*
Input frequency
50 / 60 Hz
CE, cURus*, cULus;
class 2
* Not all models
Output voltage
Output current
Order No.
class 2
5V
12 V
2A
5A
1.5 A
4A
9928890005
8754960000
9928890012
8754970000
A.40
A.41
A.39
A.42
Page
connectPower
Mains
1ph
Input voltage
85...265 V AC*,
120...300 V DC*
Input frequency
50 / 60 Hz
CE, UR / UL, CSA
* Not all models
Output voltage
Output current
Order No.
Page
VIII
5V
15 V
24 V
3A
8A
3A
8A
2.3 A
9927480005
9925340005
9927480012
9925340012
9927480024
A.47
A.49
A.47
A.49
A.46
1366860000 – 2013
Product overview
PRO-H
Mains
1ph/2ph
Input voltage
*400...500 V AC,
*100...500 V AC
*depending on model
Input frequency
50 / 60 Hz
CE; UL; UR;
Similar to illustration
Similar to illustration
Similar to illustration
100...500 V AC
100...500 V AC
100...500 V AC
Output voltage
24 V
24 V
24 V
Output current
7.5 A
15 A
25 A
1194480000
1194490000
1194310000
A.23
A.23
A.24
Rated input voltage
Order No.
Page
INSTAPOWER
Mains
1ph
Input voltage
85...265 V AC,
120...300 V DC,
110... 370 V DC
Input frequency
50 / 60 Hz
CE, cURus*, cULus;
class 2
* Not all models
class 2
Output voltage
15 V
Output current
1.5 A
1A
2A
1A
1A
9928890015
9928890024
8739140000
9928890028
8879230000
A.39
A.38
A.43
A.38
A.44
6.5 A
12.5 A
1.04 A
3.5 A
2.3 A
9925340024
9916250024
9927480048
9925340048
9917790324
A.48
A.50
A.46
A.48
A.51
Order No.
Page
24 V
28 V
48 V
connectPower
Mains
1ph / 3ph
Input voltage
85...265 V AC*,
120...300 V DC*
Input frequency
50 / 60 Hz
CE, UR / UL, CSA
* Not all models
Output voltage
Output current
Order No.
Page
1366860000 – 2013
1ph / 24 V
1ph / 48 V
3ph / 24 V
IX
Product overview
Power supplies – Selection
ECOLINE
Mains
1ph
Input voltage
90...265 V AC
Input frequency
50 / 60 Hz
Partially switchable
from 115 / 230 V AC
CE, cURus*, cULus*;
GL*, GOST
* Not all models
Output voltage
24 V
Output current
Order No.
Page
3A
5A
10 A
20 A
40 A
8708660000
8708670000
8708680000
8778870000
8862780000
A.28
A.29
A.30
A.31
A.32
ECOLINE diode modules
40 V DC max.
CE, cURus, cULus; GOST
Output voltage
40 V
Output current
Order No.
Page
2 x 10 A
2 x 20 A
8710620000
8768650000
A.37
A.37
connectPower DC/DC converter
Input voltage
9...16 V DC
CE, UL / UR, CSA,
Class 1, Div.2
Output voltage
12 V
15 V
Output current
3A
3A
2A
9919371212
9919371215
9919371224
A.53
A.53
A.53
Order No.
Page
X
24 V
1366860000 – 2013
Product overview
ECOLINE
Mains
3ph
Input voltage
3x 340...575 V AC,
Input frequency
50 / 60 Hz
CE, cURus, cULus;
GL*, GOST
* Not all models
Output voltage
24 V
Output current
Order No.
5A
10 A
20 A
40 A
8862730000
8708700000
8708710000
8708730000
A.33
A.34
A.35
A.36
Page
WAVEPOWER
Mains
1ph
85...264 V AC
120...300 V DC
CE, UL, CSA
Output voltage
24 V
Output current
0.5 A
Order No.
9918840024
Page
A.45
connectPower DC/DC converter
Input voltage
18...30 V DC
CE, UL / UR, CSA,
Class 1, Div.2
Output voltage
5V
12 V
15 V
24 V
24 V
Output current
8A
3A
3A
2A
10 A
9919372405
9919372412
9919372415
9919372424
1313320010
A.54
A.54
A.52
A.52
A.57
Order No.
Page
1366860000 – 2013
XI
Product overview
Power supplies – Selection
UPS control unit
Buffer module
Input voltage
20 ... 30 V DC
Input voltage
22.5 ... 30 V DC
CE, TÜV, cURus*, cULus*,
GL*
CE, TÜV, cURus, cULus,
GL*
* in preparation
Output voltage
24 V
24 V
* in preparation
Output voltage
24 V DC
Output current
max. 24 A
max. 48 A
Output current
max. 22 A
1370050010
1370040010
B.5
B.5
Order No.
Page
Order No.
1251220000
Page
B.8
WAVEGUARD
with
screw connection
Rated voltage
24 V DC
CE, cURus
Output voltage
Output current
Order No.
Page
24 V
1.6 A
3.15 A
6.3 A
8A
0.5...5 A
8618890000
8618910000
8618930000
8618940000
8710270000
C.4
C.4
C.5
C.5
C.6
compactPower 1ph unregulated power supplies
Mains
1ph
Input voltage
230 V / 400 V ± 15 V
Input frequency
50 / 60 Hz
CE, cURus, cULus
Output voltage
Output current
Order No.
Page
XII
24 V
1.5 A
3A
6A
8A
11 A
18 A
8575260000
8575270000
8575280000
8575300000
8575310000
8575320000
D.4
D.4
D.5
D.5
D.6
D.6
1366860000 – 2013
Product overview
Battery module
Rated voltage
24 V DC
24 V DC
24 V DC
24 V DC
Nominal capacity
1,3 Ah
3,4 Ah
7,2 Ah
12 Ah
17 Ah
in preparation
1251070000
1251080000
1251090000
1251110000
B.6
B.6
B.7
B.7
1.6 A
3.15 A
6.3 A
8A
0.5...5 A
8621040000
8621030000
8621020000
8621010000
8727630000
C.4
C.4
C.5
C.5
C.6
Order No.
Page
24 V DC
WAVEGUARD
with tension
clamp connection
Rated voltage
24 V DC
CE, cURus
Output voltage
Output current
Order No.
Page
24 V
compactPower 3ph unregulated power supplies
Mains
3ph
Input voltage
3x 400 V ± 5 %
Input frequency
50 / 60 Hz
CE, cURus, cULus
Output voltage
Output current
Order No.
Page
1366860000 – 2013
24 V
11 A
18 A
22 A
26 A
32 A
42 A
8628620000
8628630000
8628650000
8628660000
8628670000
8628680000
D.7
D.7
D.8
D.8
D.9
D.9
XIII
Product overview
Power supplies – Selection
FieldPower® IP65 switched-mode power supply
Mains
3ph
Input voltage
400 V AC
Output voltage
24 V
Output current
5A
5A
1132320000
1101940000
E.6
E.7
Order No.
Page
24 V
Electrical cabinet socket outlet
Earthed socket
outlet for the
TS35 mounting rail
VDE
Output voltage
Output current
Order No.
Page
XIV
250 V AC
16 A
8734580000
E.24
1366860000 – 2013
Switch-mode power supplies
Contents
Switch-mode power supplies
Switch-mode power supplies
1366860000 – 2013
Overview
A.2
connectPower PRO-M
A.4
connectPower PRO-H
A.16
connectPower ECOLINE
A.28
connectPower INSTAPOWER
A.38
connectPower WAVEPOWER
A.45
connectPower
A.46
connectPower DC/DC converter
A.52
A
A.1
Switch-mode power supplies
Switch-mode power supplies – Overview
Switch-mode power supplies
The switch-mode power supplies feature a high degree
of efficiency, compact dimensions and minimal heat
generation.
A
They are an excellent, reliable solution for providing power
in all automation applications – safely providing 24 V DC
voltage.
The different product series are optimised for the automation
industry: they feature Ex approvals for the processing
industry, a flat shape perfect for distribution tasks within
buildings, or provide decentralised control voltages.
are possible using simple parallel circuitry. Weidmüller
switch-mode power supplies can be depended upon for
all applications because of their high efficiency and their
resistance to both short circuits and overloads.
Wedimüller offers a system of one- and three-phase swtichmode power supplies especially for the PRO-M family. These
can be expanded with additional modules to create whole
system solutions. The appropriate system can be assembled
for any type of application: with redundancy circuits
containing decoupled outputs, monitoring of the output
voltage or triggering of circuit breakers.
All-purpose usage: with a wide range of AC/DC inputs,
single-, double- or three-phase versions, and a wide
temperature range. Additional performance increases
A.2
1366860000 – 2013
Switch-mode power supplies
Switch-mode power supplies – Overview
AC / DC
International use
Parallel connection
from 3
3
mm
A
A wide-range input (both DC
as well as AC voltages can be used;
no switching required) and extensive
approvals (UL/CSA and GL
(EMC 1 – bridge)).
connectPower
Module power can be increased by
connecting upto five power supplies in
parallel without diode module.
connectPower PRO-M
Narrow
connectPower PRO-H
Space-saving configuration in the
switching cabinet through very narrow
housing construction and side-by-side
connectability.
connectPower ECOLINE
Robust
Wide temperature range from
–25 °C … +70 °C.
connectPower INSTAPOWER
Wide choice
The right power supply for every
application: 1-phase 3 A, 5 A, 7.5 A,
10 A, 20 A, 40 A and 3-phase 5 A,
10 A, 20 A, 40 A.
connectPower WAVEPOWER
connectPower
connectPower DC/DC converters
1366860000 – 2013
A.3
Switch-mode power supplies
connectPower PRO-M
connectPower
PRO-M
A
%
{ \u
"
Technical data
L (+)
AC
N (–)
+
DC
PE
–
Pay attention to polarity of DC connection
L1 (+)
L2 (–)
L3
PE
AC
+
DC
–
Two-Phase operation also possible
Max. limiting average on state current [A]
Type\Temp.
1ph 24V / 3A
1ph 24V / 5A
1ph 24V / 7.5A
1ph 24V / 10A
1ph 24V / 20A
1ph 24V / 40A
3ph 24V / 5A
3ph 24V / 10A
3ph 24V / 20A
3ph 24V / 40A
45°C
3.6
6
9
12
24
48
6
12
24
48
50°C
3.4
5.7
8.5
11.3
22.7
45.3
5.7
11.3
22.7
45.3
55°C
3.2
5.3
8
10.7
21.3
42.7
5.3
10.7
21.3
42.7
60°C
3
5
7.5
10
20
40
5
10
20
40
Project-planning data
Type
Rated input voltage
Mains voltage range
Mains input current
Rec. fuse [char.]
Efficiency @ 230 V AC, @ 3x400 V AC
Rated power loss [W]
Installation width
Input terminals
Conductor, solid min/max
Conductor, flexible min/max
Conductor, AWG/kcmil min/max
Output terminals
Number plus/minus
Conductor, solid min/max
Conductor, flexible min/max
Conductor, AWG/kcmil min/max
A.4
mm
65°C
2.6
4.4
6.6
8.8
17.5
35
4.4
8.8
17.5
35
General technical data
Current limiting
Ambient temp. operating / storage temperature
Max. perm. air humidity (operation)
Degree of protection
Class of protection
Pollution degree
Insulation voltage input/output
MTBF
Protection against reverse voltages from the load
Parallel connection option
Housing version
Indication
Mounting position, installation notice
EMC / shock / vibration
Noise emission acc. to EN55022
Noise immunity tests acc. to
70°C
2.3
3.8
5.6
7.5
15
30
3.8
7.5
15
30
24 V / 5 A
1.3...0.6 A
2 A / D I / II
6 A, [B]
2...4 A, [C]
90 %
8W
33
2.1...0.9 A
4 A / D I / II
6 A, [B]
3...5 A, [C]
90 %
13 W
40
24 V / 7.5 A
24 V / 10 A
1 - phase
100...240 V AC
85...264 V AC
2.1...0.9 A
2.8...1.2 A
6 A / D I / II
6 A / D I / II
10 A, [B]
10 A, [B]
5...10 A, [C]
5...10 A, [C]
91 %
90 %
18 W
27 W
50
60
Acc. to EN60204
Acc. to EN61558-2-17
Acc. to EN50178 / VDE0160
SELV acc. to EN60950, PELV acc. to EN60204
VDE0100-410 / acc. to DIN57100-410
Acc. to VDE0106-101
24 V / 20 A
24 V / 40 A
24 V / 5 A
5.6...2.4 A
10 A / D I / II
20 A, [B]
10...12 A, [C]
90 %
53 W
121
11.1...4.7 A
16 A / D I / II
25 A, [B]
14...16 A, [C]
91 %
95 W
180
0.3...0.28 A
2 A / D I / II
1...2 A, [C]
90 %
13 W
40
0.5...6
0.5...2.5
26 / 12
Screw connection
0.5...6
0.5...2.5
26 / 10
0.5...6
0.5...2.5
26 / 12
Screw connection
2/3
0.5...6
0.5...16
0.5...2.5
2.5...10
26 / 10
22 / 6
2/2
mm2
mm2
Class B
EN61000-4-2 (ESD), EN61000-4-3 und EN61000-4-8 (Fields),
EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN610004-6 (conducted),
EN61000-4-11 (Dips)
Acc. to EN 61000-3-2
Acc. to EN50178, shock: 30 g in all directions
Limiting of mains voltage harmonic currents
Resistance against vibration and shock
Electrical safety (applied standards)
Electrical equipment of machines
Safety transformers for switched-mode power units
Machinery with electronic equipment
Safety extra-low voltage
Protective separation / protection against electrical shock
Protection against dangerous shock currents
24 V / 3 A
mm2
mm2
> 120 % IN
–25 °C…+70 °C / –40 °C… +85 °C
5 %…95 % RH
IP20
I, with PE connection
2
3 kV I/O / 2 kV I/earth / 0.5 kV O/earth
> 500.000 h acc. to IEC 1709 (SN29500)
30…35 V DC
yes, without diode module
metal, corrosion resistant
operation, green LED
horizontal on mounting rail TS35, 50 mm spacing top and bottom for free
air circulation, can be mounted side by side with no space in between
24 V / 10 A
24 V / 20 A
3 - phase
3 x 400...500 V AC
3 x 320...575 V AC
0.55...0.5 A
1.0...0.9 A
2 A / D I / II
2 A / D I / II
2...3 A, [C]
3...5 A, [C]
90 %
90 %
27 W
53 W
60
121
0.08...4
0.5...2.5
28 / 12
0.5...6
0.5...2.5
26 / 12
0.5...6
0.5...2.5
26 / 12
24 V / 40 A
2.5...2.0 A
4 A / D I / II
10 A, [B]
6...8 A, [C]
91 %
95 W
180
0.5...6
0.5...2.5
26 / 12
0.5...6
0.5...2.5
26 / 10
0.5...16
2.5...10
22 / 6
1366860000 – 2013
connectPower
PRO-M
CP M SNT 70W 24V 3A
Switch-mode power supplies
connectPower PRO-M
CP M SNT 120W 24V 5A
A
D
L (+)
N (–)
H
AC
PE
+
N (–)
DC
–
With DC connection, note polarity
W
L (+)
AC
+
DC
PE
–
With DC connection, note polarity
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / making current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
Powerboost @ 24 V DC, 60 °C
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Parallel connection option
Height x width x depth
Weight
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
mm²
mm²
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
0.6 A @ 230 V AC / 1.1 A @ 115 V AC
0.25 A @ 370 V DC / 0.7 A @ 120 V DC
Yes / max. 40 A
2 A / DI, safety fuse
6 A, Char. B, circuit breaker
2...4 A, Char. C, circuit breaker
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
1.1 A @ 230 V AC / 2.0 A @ 115 V AC
0.4 A @ 370 V DC / 1.2 A @ 120 V DC
Yes / max. 40 A
4 A / DI, safety fuse
6 A, Char. B, circuit breaker
3...5 A, Char. C, circuit breaker
24 V DC ± 1 %
22.5...29.5 V DC (adjustable via potentiometer on front)
< 50 mVSS @ 24 V DC, IN
3 A @ 60 °C
3.6 A @ 45 °C, 3.2 A @ 55 °C, 2.3 A @ 70 °C
3.6 A for 1 min, ED = 5 %
24 V DC ± 1 %
22.5...29.5 V DC (adjustable via potentiometer on front)
< 50 mVSS @ 24 V DC, IN
5 A @ 60 °C
6.0 A @ 45 °C, 5.3 A @ 55 °C, 3.8 A @ 70 °C
6 A for 1 min, ED = 5 %
90 % @ 230 V AC / 88 % @ 115 V AC
> 0.6 @ 230 V AC / > 0,65 @ 115 V AC
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 5
130 / 33 / 125 mm
0.57 kg
90 % @ 230 V AC / 88 % @ 115 V AC
> 0.5 @ 230 V AC / > 0.6 @ 115 V AC
> 100 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 5
130 / 40 / 125 mm
0.7 kg
cULus; cURus; GL; GOSTME25
CE; cULus; cURus; GL; GOSTME25
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Output
Screw connection
4 (++ / --)
0.5 / 6
0.5 / 2.5
26 / 12
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Output
Screw connection
5 (++ / ---)
0.5 / 6
0.5 / 2.5
26 / 12
*) Recommendation applies only to AC operation; the max. permissible
operating voltage is to be observed in all cases!
*) Recommendation applies only to AC operation; the max. permissible
operating voltage is to be observed in all cases!
Type
CP M SNT 70W 24V 3A
CP M SNT 70W 24V 3A
Type
CP M SNT 120W 24V 5A
CP M SNT 120W 24V 5A
Ordering data
Plastic clip-on foot
Metal clip-on foot
Qty.
1
1
Order No.
8951330000
8951330010
Qty.
1
1
Order No.
8951340000
8951340010
Note
Accessories
Note
1366860000 – 2013
A.5
Switch-mode power supplies
connectPower PRO-M
connectPower
PRO-M
CP M SNT 180W 24V 7.5A
CP M SNT 250W 24V 10A
A
D
L (+)
N (–)
H
AC
+
N (–)
DC
PE
–
With DC connection, note polarity
W
L (+)
AC
+
DC
PE
–
With DC connection, note polarity
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / making current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
Powerboost @ 24 V DC, 60 °C
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Parallel connection option
Height x width x depth
Weight
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
mm²
mm²
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
0.9 A @ 230 V AC / 1.8 A @ 115 V AC
0.6 A @ 370 V DC / 1.7 A @ 120 V DC
Yes / max. 40 A
6 A / DI, safety fuse
10 A, Char. B, circuit breaker
6 A, Char. C, circuit breaker
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
1.2 A @ 230 V AC / 2.4 A @ 115 V AC
0.8 A @ 370 V DC / 2.3 A @ 120 V DC
Yes / max. 12 A
4 A / DI, safety fuse
10 A, Char. B, circuit breaker
3...4 A, Char. C, circuit breaker
24 V DC ± 1 %
22.5...29.5 V DC (adjustable via potentiometer on front)
< 50 mVSS @ 24 V DC, IN
7,5 A @ 60 °C
9.0 A @ 45 °C, 8.0 A @ 55 °C, 5.6 A @ 70 °C
9 A for 1 min, ED = 5 %
24 V DC ± 1 %
22.5...29.5 V DC (adjustable via potentiometer on front)
< 50 mVSS @ 24 V DC, IN
10 A @ 60 °C
12 A @ 45 °C, 10.7 A @ 55 °C, 7.5 A @ 70 °C
12 A for 1 min, ED = 5 %
91 % @ 230 V AC / 88 % @ 115 V AC
> 0.94 @ 230 V AC / > 0.99 @ 115 V AC
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 5
130 / 50 / 150 mm
1.05 kg
90 % @ 230 V AC / 87 % @ 115 V AC
> 0.99 @ 230 V AC / > 0.97 @ 115 V AC
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 5
130 / 60 / 150 mm
1.2 kg
CE; cULus; cURus; GL; GOSTME25
cULus; cURus; GL; GOSTME25
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Output
Screw connection
5 (++ / ---)
0.5 / 6
0.5 / 2.5
26 / 12
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Output
Screw connection
5 (++ / ---)
0.5 / 6
0.5 / 2.5
26 / 12
*) Recommendation applies only to AC operation; the max. permissible
operating voltage is to be observed in all cases!
*) Recommendation applies only to AC operation; the max. permissible
operating voltage is to be observed in all cases!
Type
CP M SNT 180W 24V 7,5A
CP M SNT 180W 24V 7,5A
Type
CP M SNT 250W 24V 10A
CP M SNT 250W 24V 10A
Ordering data
Plastic clip-on foot
Metal clip-on foot
Qty.
1
1
Order No.
8951350000
8951350010
Qty.
1
1
Order No.
8951360000
8951360010
Note
Accessories
Note
A.6
1366860000 – 2013
connectPower
PRO-M
CP M SNT 500W 24V 20A
Switch-mode power supplies
connectPower PRO-M
CP M SNT 1000W 24V 40A
A
D
L (+)
N (–)
H
AC
+
N (–)
DC
PE
–
With DC connection, note polarity
W
L (+)
AC
+
DC
PE
–
With DC connection, note polarity
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / making current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
Powerboost @ 24 V DC, 60 °C
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Parallel connection option
Height x width x depth
Weight
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
mm²
mm²
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
2.4 A @ 230 V AC / 4.8 A @ 115 V AC
1.5 A @ 370 V DC / 4.6 A @ 120 V DC
Yes / max. 5 A
6 A / DI, safety fuse
16 A, Char. B, circuit breaker
6...8 A, Char. C, circuit breaker
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
4.7 A @ 230 V AC / 9.6 A @ 115 V AC
2.9 A @ 370 V DC / 9.1 A @ 120 V DC
Yes / max. 5 A
16 A / DI, safety fuse
20 A, Char. B, circuit breaker
16 A, Char. C, circuit breaker
24 V DC ± 1 %
22.5...29.5 V DC(adjustable via potentiometer on front)
< 50 mVSS @ 24 V DC, IN
20 A @ 60 °C
24 A @ 45 °C, 22.7 A @ 55 °C, 15 A @ 70 °C
24 A for 1 min, ED = 5 %
24 V DC ± 1 %
22.5...29.5 V DC (adjustable via potentiometer on front)
< 50 mVSS @ 24 V DC, IN
40 A @ 60 °C
48 A @ 45 °C, 42.7 A @ 55 °C, 30 A @ 70 °C
48 A for 1 min, ED = 5 %
90 % at 230 V AC / > 85 % at 115 V AC
> 0.98 @ 230 V AC / > 0.99 @ 115 V AC
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 3
130 / 121 / 150 mm
2.2 kg
91 % @ 230 V AC / 88 % @ 115 V AC
> 0.99 @ 230 V AC / > 0.99 @ 115 V AC
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 5
130 / 180 / 150 mm
3.9 kg
cULus; cURus; GL; GOSTME25
cULus; cURus; GL; GOSTME25
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 10
Output
Screw connection
5 (++ / ---)
0.5 / 6
0.5 / 2.5
26 / 10
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 10
Output
Screw connection
5 (++ / ---)
0.5 / 16
2.5 / 10
22 / 6
*) Recommendation applies only to AC operation; the max. permissible
operating voltage is to be observed in all cases!
*) Recommendation applies only to AC operation; the max. permissible
operating voltage is to be observed in all cases!
Type
CP M SNT 500W 24V 20A
CP M SNT 500W 24V 20A
Type
CP M SNT 1000W 24V 40A
CP M SNT 1000W 24V 40A
Ordering data
Plastic clip-on foot
Metal clip-on foot
Qty.
1
1
Order No.
8951370000
8951370010
Qty.
1
1
Order No.
8951380000
8951380010
Note
Accessories
Note
1366860000 – 2013
A.7
Switch-mode power supplies
connectPower PRO-M
connectPower
PRO-M
CP M SNT3 120W 24V 5A
CP M SNT3 250W 24V 10A
A
D
L1 (+)
L2 (–)
L3
PE
H
AC
+
DC
–
With DC connection, note polarity
Two-phase operation also possible
W
L1 (+)
L2 (–)
L3
PE
AC
+
DC
–
With DC connection, note polarity
Two-phase operation also possible
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / making current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
Powerboost @ 24 V DC, 60 °C
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Parallel connection option
Height x width x depth
Weight
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
mm²
mm²
3 x 400...3 x 500 V AC (wide-range input)
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
47...63 Hz
450...800 V DC (max. 500 V DC acc. to UL508)
0.28 A @ 3 x 500 V AC / 0.3 A @ 3 x 400 V AC
0.18 A @ 800 V DC / 0.3 A @ 450 V DC
No / max. 50 A
2 A / DI, safety fuse
2...3 A, Char. C, circuit breaker
3 x 400...3 x 500 V AC (wide-range input)
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
47...63 Hz
450...800 V DC (max. 500 V DC acc. to UL508)
0.5 A @ 3 x 500 V AC / 0.55 A @ 3 x 400 V AC
0.35 A @ 800 V DC / 0.6 A @ 450 V DC
No / max. 50 A
2 A / DI, safety fuse
2...3 A, Char. C, circuit breaker
24 V DC ± 1 %
22.5...29.5 V DC (adjustable via potentiometer on front)
< 50 mVSS @ 24 V DC, IN
5 A @ 60 °C
6.0 A @ 45 °C, 5.3 A @ 55 °C, 3.8 A @ 70 °C
6 A for 1 min, ED = 5 %
24 V DC ± 1 %
22.5...29.5 V DC (adjustable via potentiometer on front)
< 50 mVSS @ 24 V DC, IN
10 A @ 60 °C
12 A @ 45 °C, 10.7 A @ 55 °C, 7.5 A @ 70 °C
12 A for 1 min, ED = 5 %
89 % @ 3 x 500 V AC / 90 % @ 3 x 400 V AC
> 0.55 @ 3 x 500 V AC / > 0.65 @ 3 x 400 V AC
> 50 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC
yes, max. 5
130 / 40 / 125 mm
0.7 kg
89 % @ 3 x 500 V AC / 90 % @ 3 x 400 V AC
> 0.65 @ 3 x 500 V AC / > 0.75 @ 3 x 400 V AC
> 40 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC
yes, max. 5
130 / 60 / 150 mm
1.25 kg
cULus; cURus; GL; GOSTME25
cULus; cURus; GL; GOSTME25
Input
Screw connection
4 for L1/L2/L3/PE
0.08 / 4
0.5 / 2.5
28 / 12
Output
Screw connection
5 (++ / ---)
0.5 / 6
0.5 / 2.5
26 / 12
Input
Screw connection
4 for L1/L2/L3/PE
0.5 / 6
0.5 / 2.5
26 / 12
Output
Screw connection
5 (++ / ---)
0.5 / 6
0.5 / 2.5
26 / 12
*) Recommendation applies only to AC operation; the max. permissible
operating voltage is to be observed in all cases!
*) Recommendation applies only to AC operation; the max. permissible
operating voltage is to be observed in all cases!
Type
CP M SNT3 120W 24V 5A
CP M SNT3 120W 24V 5A
Type
CP M SNT3 250W 24V 10A
CP M SNT3 250W 24V 10A
Ordering data
Plastic clip-on foot
Metal clip-on foot
Qty.
1
1
Order No.
8951390000
8951390010
Qty.
1
1
Order No.
8951400000
8951400010
Note
Accessories
Note
A.8
1366860000 – 2013
connectPower
PRO-M
CP M SNT3 500W 24V 20A
Switch-mode power supplies
connectPower PRO-M
CP M SNT3 1000W 24V 40A
A
D
L1 (+)
L2 (–)
L3
PE
H
AC
+
DC
–
With DC connection, note polarity
Two-phase operation also possible
W
L1 (+)
L2 (–)
L3
PE
AC
+
DC
–
With DC connection, note polarity
Two-phase operation also possible
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / making current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
Powerboost @ 24 V DC, 60 °C
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Parallel connection option
Height x width x depth
Weight
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
mm²
mm²
3 x 400...3 x 500 V AC (wide-range input)
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
47...63 Hz
450...800 V DC (max. 500 V DC acc. to UL508)
0.9 A @ 3 x 500 V AC / 0.95 A @ 3 x 400 V AC
0.7 A @ 800 V DC / 1.2 A @ 450 V DC
No / max. 50 A
4 A / DI, safety fuse
3...5 A, Char. C, circuit breaker
3 x 400...3 x 500 V AC (wide-range input)
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
47...63 Hz
450...800 V DC (max. 500 V DC acc. to UL508)
2.0 A @ 3 x 500 V AC / 2.5 A @ 3 x 400 V AC
1.3 A @ 800 V DC / 2.4 A @ 450 V DC
No / max. 60 A
6 A / DI, safety fuse
10 A, Char. B, circuit breaker
6...8 A, Char, C, circuit breaker
24 V DC ± 1 %
22.5...29.5 V DC (adjustable via potentiometer on front)
< 50 mVSS @ 24 V DC, IN
20 A @ 60 °C
24 A @ 45 °C, 21.3 A @ 55 °C, 15 A @ 70 °C
24 A for 1 min, ED = 5 %
24 V DC ± 1 %
22.5...29.5 V DC (adjustable via potentiometer on front)
< 50 mVSS @ 24 V DC, IN
40 A @ 60 °C
48 A @ 45 °C, 42.7 A @ 55 °C, 30 A @ 70 °C
48 A for 1 min, ED = 5 %
89 % @ 3 x 500 V AC / 90 % @ 3 x 400 V AC
< 0.69 @ 3 x 500 V AC / > 0.82 @ 3 x 400 V AC
> 25 ms at 3 x 500 V AC / > 20 ms at 3 x 400 V AC
yes, max. 3
130 / 121 / 150 mm
2.2 kg
91 % @ 3 x 500 V AC / 91 % @ 3 x 400 V AC
> 0.6 @ 3 x 500 V AC / > 0.6 @ 3 x 400 V AC
> 25 ms at 3 x 500 V AC / > 20 ms at 3 x 400 V AC
yes, max. 3
130 / 180 / 150 mm
4 kg
cULus; cURus; GL; GOSTME25
cULus; cURus; GL; GOSTME25
Input
Screw connection
4 for L1/L2/L3/PE
0.5 / 6
0.5 / 2
26 / 10
Output
Screw connection
5 (++ / ---)
0.5 / 6
0.5 / 2.5
26 / 10
Input
Screw connection
4 for L1/L2/L3/PE
0.5 / 6
0.5 / 2.5
26 / 10
Output
Screw connection
5 (++ / ---)
0.5 / 16
0.5 / 10
22 / 6
*) Recommendation applies only to AC operation; the max. permissible
operating voltage is to be observed in all cases!
*) Recommendation applies only to AC operation; the max. permissible
operating voltage is to be observed in all cases!
Type
CP M SNT3 500W 24V 20A
CP M SNT3 500W 24V 20A
Type
CP M SNT3 1000W 24V 40A
CP M SNT3 1000W 24V 40A
Ordering data
Plastic clip-on foot
Metal clip-on foot
Qty.
1
1
Order No.
8951410000
8951410010
Qty.
1
1
Order No.
8951420000
8951420010
Note
Accessories
Note
1366860000 – 2013
A.9
Switch-mode power supplies
connectPower PRO-M
PRO-M: diode, capacity
and relay modules
CP M DM20
CP M DM40
A
D
1+
12-
H
W
3+
4+
11
12
14
34-
21
22
24
2+
1+
12-
3+
4+
11
12
14
34-
21
22
24
2+
Technical data
Input
Rated input voltage / DC input voltage range
Input current
Output
Rated output voltage / Output voltage
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
Voltage monitoring / Floating contact
Switching thresholds
24 V DC / 18…30 V DC
2 x 10 A or 1 x 20 A
24 V DC / 18…30 V DC
2 x 20 A or 1 x 40 A
24 V DC ± 1 % / Input voltage - 0.7 V
20 A @ 60 °C
24 A @ 45 °C, 22.5 A @ 55 °C, 15 A @ 70 °C
Yes, In both inputs / Yes
21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for
Power Fail
24 V DC ± 1 % / Input voltage - 0.7 V
40 A @ 60 °C
48 A @ 45 °C, 45 A @ 55 °C, 30 A @ 70 °C
Yes, In both inputs / Yes
21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for
Power Fail
> 97% @ 24 V input voltage
130 / 34 / 150 mm / 0.3 kg
-25 °C...+70 °C / -40 °C...+85 °C
5...95 %, no condensation
IP 20 / III, with no ground connection, for SELV / 2
0.5 kV Input/output housing
> 500,000 h acc. to IEC 1709 (SN29500
Horizontal on TS35 mounting rail,w. 50 mm clearance at top/bottom
for air circulation. Can be mount side by side w. no space in between.
> 97% @ 24 V input voltage
130 / 60 / 150 mm / 0.6 kg
-25 °C...+70 °C / -40 °C...+85 °C
5...95 %, no condensation
IP 20 / III, with no ground connection, for SELV / 2
0.5 kV Input/output housing
> 500,000 h acc. to IEC 1709 (SN29500
Horizontal on TS35 mounting rail,w. 50 mm clearance at top/bottom
for air circulation. Can be mount side by side w. no space in between.
Class B
EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN
61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)
Class B
EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN
61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)
Resistance to vibration / Shock
Electrical safety (applied standards)
Electrical machine equipment
For use with electronic equipment
Safety extra-low voltage
Approvals
Approvals
1 g according to EN50178 / 15 g In all directions
1 g according to EN50178 / 15 g In all directions
Acc. to EN60204
Acc. to EN50178 / VDE0160
SELV acc. to EN60950, PLEV acc. to EN60204
Acc. to EN60204
Acc. to EN50178 / VDE0160
SELV acc. to EN60950, PLEV acc. to EN60204
cCSAus; cULus; GL; GOSTME25
cCSAus; cULus; GL; GOSTME25
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Input
Screw connection
4 (1+, 2+, 1-, 2-)
0.5 / 6
0.5 / 2.5
26 / 12
General data
Degree of efficiency
Height x width x depth / Weight
Ambient temperature (operational) / Storage temperature
Humidity
Protection degree / Class of protection / Pollution severity
Insulation voltage
MTBF
Mounting position, installation notice
EMC / shock / vibration
Noise emission acc. to EN55022
Interference immunity test acc. to
mm²
mm²
Output
Screw connection
4 (3 +, 4 +, 3 -, 4 -)
0.5 / 6
0.5 / 2.5
26 / 12
Input
Screw connection
4 (1+, 2+, 1-, 2-)
0.5 / 16
2.5 / 10
22 / 6
Output
Screw connection
4 (3 +, 4 +, 3 -, 4 -)
0.5 / 16
2.5 / 10
22 / 6
Ordering data
Plastic clip-on foot
Metal clip-on foot
Type
CP M DM20
CP M DM20
Qty.
1
1
Order No.
1222210000
1222210010
Type
CP M DM40
CP M DM40
Qty.
1
1
Order No.
1222220000
1222220010
Note
Accessories
Note
A.10
1366860000 – 2013
PRO-M: diode, capacity
and relay modules
Switch-mode power supplies
connectPower PRO-M
CP M RM24
A
red
+
black
–
11
H
12
14
D
W
Technical data
Input
Rated input voltage
DC input voltage range
Output
Voltage monitoring
Switching thresholds
24 V DC
18…30 V DC
Yes
21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for
Power Fail
max. 250 V AC / 1 A, Relay
Floating output
General data
Height x width x depth
Weight
Ambient temperature (operational) / Storage temperature
Humidity
Protection degree
Class of protection
Pollution severity
Insulation voltage
MTBF
Mounting position, installation notice
28 / 33 / 22 mm
75 kg
-25 °C...+70 °C / -40 °C...+85 °C
5...95 %, no condensation
IP 20
III, with no ground connection, for SELV
2
0.5 kV Input/output housing
> 500,000 h acc. to IEC 1709 (SN29500
Plugged in to the front of the PRO-M power supply
EMC / shock / vibration
Noise emission acc. to EN55022
Interference immunity test acc. to
Class B
EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN
61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6
(conducted)|EN 61000-4-11 (dips)
1 g according to EN50178 / 15 g In all directions
Resistance to vibration / Shock
Electrical safety (applied standards)
Electrical machine equipment
For use with electronic equipment
Safety extra-low voltage
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Acc. to EN60204
Acc. to EN50178 / VDE0160
SELV acc. to EN60950, PLEV acc. to EN60204
cURus; GL; GOSTME25
Input
PUSH IN
mm²
mm²
Output
PUSH IN
3 (CO contacts)
0.2 / 1.5
0.2 / 1.5
24 / 16
Ordering data
Type
CP M RM24
Qty.
1
Order No.
1222230000
Note
Accessories
Note
1366860000 – 2013
A.11
Switch-mode power supplies
connectPower PRO-M
PRO-M: diode, capacity
and relay modules
CP M CAP
Pulse triggering for cable circuit breakers:
with the Weidmüller capacitance module
The following conditions apply to the table entries:
• Ambient temperature of 20 °C
• Inner resistance of the circuit breakers is taken into account
• Half of the rated current flows to a neighbouring circuit before the
short circuit is formed
• DC-compatible circuit breakers: Siemens 5SY series
1+
2+
+
11
12
14
H
12-
W
Distance in m
Technical data
Fuse tripping
Input
Rated input voltage / DC input voltage range
Output
Peak current output / Recovery time for the capacitor
Switching thresholds
24 V DC / 18…30 V DC
Depending on the load (typically 40 A for 1 ms) / Approx. 1 sec.
21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for
Power Fail
Yes
Floating contact
General data
Height x width x depth / Weight
Ambient temperature (operational) / Storage temperature
Humidity
Protection degree / Class of protection / Pollution severity
Insulation voltage
MTBF
Mounting position, installation notice
130 / 34 / 150 mm / 0.4 kg
-25 °C...+70 °C / -40 °C...+85 °C
5...95 %, no condensation
IP 20 / III, with no ground connection, for SELV / 2
0.5 kV Input/output housing
> 500,000 h acc. to IEC 1709 (SN29500
Horizontal on TS35 mounting rail,w. 50 mm clearance at top/bottom
for air circulation. Can be mount side by side w. no space in between.
EMC / shock / vibration
Noise emission acc. to EN55022
Interference immunity test acc. to
Class B
EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN
61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6
(conducted)|EN 61000-4-11 (dips)
1 g according to EN50178 / 15 g In all directions
Resistance to vibration / Shock
Electrical safety (applied standards)
Electrical machine equipment
For use with electronic equipment
Safety extra-low voltage
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
cULus; GL; GOSTME25
mm²
mm²
Conductor cross section
0.75 mm2
1.0 mm2
1.5 mm2
2.5 mm2
4 mm2
6 mm2
0.75 mm2
1.0 mm2
1.5 mm2
2.5 mm2
4 mm2
6 mm2
0.75 mm2
1.0 mm2
1.5 mm2
2.5 mm2
4 mm2
6 mm2
0.75 mm2
1.0 mm2
1.5 mm2
2.5 mm2
4 mm2
6 mm2
Acc. to EN60204
Acc. to EN50178 / VDE0160
SELV acc. to EN60950, PLEV acc. to EN60204
Input
Screw connection
4 (++--)
0.5 / 6
0.5 / 4
26 / 12
Load
D
Power supply
+
CAP module
A
B6
10 m
14 m
20 m
30 m
50 m
B10
6 m
9 m
15 m
24 m
B16
4m
6m
10 m
16 m
C2
11 m
14 m
21 m
34 m
C6
3m
3.5 m
5.5 m
9m
14 m
C4
6 m
8 m
12 m
19 m
32 m
C10
2 m
3 m
5 m
8 m
12 m
Output
Screw connection
3 (CO contacts)
0.5 / 6
0.5 / 2.5
26 / 12
For low-impedance connections we recommend 2.5 mm².
Ordering data
Plastic clip-on foot
Metal clip-on foot
Type
CP M CAP
CP M CAP
Qty.
1
1
Order No.
1222240000
1222240010
Note
Accessories
Note
A.12
1366860000 – 2013
A
1366860000 – 2013
A.13
Switch-mode power supplies
Switch-mode power supplies
connectPower PRO-M
A
PRO-M: Application solution for wind power
Switched-mode power supply with wide-range
input
Application solution for wind power:
•80 ... 430 V DC input
•Alarm contact
•Metal snap-on foot
%
{
\u
Technical data
General technical data
Output characteristic curve / current limit
Earth discharge current
Ambient temperature (operational) / Storage temperature
Max. permitted humidity (operational)
Degree of protection
Class of protection
Pollution degree
Insulation voltage
MTBF
Protection against reverse voltages from the load
Can be connected in parallel
Housing version
Signal indication
Mounting position, installation notice
Voltage derating
110
Pout [% Pn]
190
90
80
70
60
50
40
80
120
160
200
240
280
320
360
400
440
DC Input [V]
Temperature derating
130
120
EMC / shock / vibration
Noise emission acc. to EN55022
Noise immunity tests acc. to
Pout [% Pn]
110
100
90
80
70
60
20
30
40
50
60
Ambient temperature [°C]
A.14
70
80
Limiting of mains voltage harmonic currents
Resistance against vibration and shock
Electrical safety (applied standards)
Electrical equipment of machines
Safety transformers for switched-mode power units
Safety transformers for switched-mode power units
Safety extra low voltage
Protective separation / protection against electrical shock
Protection against dangerous shock currents
IU / > 120 % IN
< 3.5 mA
–25 °C … +70 °C / –40 °C … +85 °C
5 %…95 % RH
IP20
I, with PE connection
2
3 kV AC 1 min. / 2 kV AC 1 min. / 0.5 kV AC 1 min.
> 500,000 h according to IEC 1709 (SN29500)
30…35 V DC
Yes, without diode module
Metal, corrosion resistant
Operations, green/red LED
Horizontal on TS35 mounting rail, with 50 mm of clearance at top and
bottom for air circulation. Can be mounted side by side with no space in
between. Suitable for installation in rotating systems.
Class B
EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields),
EN61000-4-4 (Burst), EN61000-4-5 (Surge),
EN610004-6 (conducted), EN61000-4-11 (Dips)
according to EN61000-3-2
according to EN50178, Shock: 5 g in all directions
according to EN60204
according to EN61558-2-17
according to EN50178 / VDE0160
SELV according to EN60950, PELV according to EN60204
VDE0100-410 / according to DIN57100-410
according to VDE0106-101
1366860000 – 2013
PRO-M: application solutions for
wind power
Switch-mode power supplies
connectPower PRO-M
CP M SNT 250 W 24 V 10 A UW
A
D
L (+)
N (–)
H
AC
PE
+
+
–
–
11
14
DC
U <<
Bei DC-Anschluss auf Polarität achten
W
Technical data
Input
Rated input voltage / Input voltage range AC
100...240 V AC (wide-range input) / 85…264 V AC (Derating @
100 V AC)
47...63 Hz
80…430 V DC
1.2 A @ 230 V AC / 2.4 A @ 115 V AC
0.8 A @ 370 V DC / 2.3 A @ 120 V DC
Yes
4 A / DI, safety fuse
10 A, Char. B, circuit breaker
3...4 A, Char. C, circuit breaker
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal)
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Height x width x depth / Weight
Additional equipment
Status indicator
Relay on/off
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
24 V DC ± 1 %
22.5...29.5 V DC (adjustable via potentiometer on front)
< 50 mVSS @ 24 V DC, IN
10 A @ 60 °C
12 A @ 45 °C, 10.7 A @ 55 °C, 7.5 A @ 70 °C
90 % @ 230 V AC / 87 % @ 115 V AC
> 0.99 @ 230 V AC / > 0.97 @ 115 V AC
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC
130 / 60 / 155 mm / 1.2 Kg
Green LED, red LED
Output voltage > 21.6 V / < 20.4 V
cULus; cURus; GL; GOSTME25
mm²
mm²
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Output
Screw connection
6 (+,+,-,-,COM,NO)
0.5 / 6
0.5 / 2.5
26 / 12
Ordering data
Type
CP M SNT 250W 24V 10AUW
Qty.
1
Order No.
1165480010
Note
Accessories
Note
1366860000 – 2013
A.15
Switch-mode power supplies
connectPower PRO-H
connectPower
PRO-H
A
% { \ | CB
Scheme
Technical data
L (+)
N (–)
AC
General technical data
Current limiting
Ambient temp. operating / storage temperature
Max. perm. air humidity (operation)
Degree of protection
Class of protection
Pollution degree
Insulation voltage input/output
MTBF according to IEC 61709
+
DC
PE
–
> 100 % IN
-25…+70 °C -25 °C…+85 °C
95 % RH
IP20
I, with PE connection
2
4 kV I/O 2 kV I/earth 0.5 kV O/earth
> 1.8 Mio. h
CP T … 70/90 W > 1.2 Mio. h
CP T … 140 W
CP T … 180/360/600 W > 0.9 Mio. h
16 V DC / 35 V DC / 63 V DC
yes, without diode module
metal, corrosion resistant
Thermal protection, autom. restart
Unlimited, autom. restart
Dual LED Operational: Green LED; Error: Red LED
Horizontal on TS35 mounting rail, with 80 mm space at top and bottom.
Side by side mounting with 50 mm clearance.
Protection against reverse voltages from the load
Parallel connection option
Housing version
Overload protection
Short circuit protection
Indication
Mounting position, installation notice
Signal indication
Power Good Signal
Trigger point 12 V version 9…11 V DC
24 V version 18...22 V DC
48 V version 36...44 V DC
NO contact 30 V DC/1.0 A max. for 12/24 V DC modules
48 V DC/ 0.5 A max. for 36/48 V DC modules
70 W
11 V DC ± 1 V DC / 20 mA max.
140 W
11 V DC ± 1 V DC / 40 mA max.
90 W
22 V DC ± 2 V DC / 10 mA max.
22 V DC± 2 V DC / 20 mA max.
180/360/600 W 24 V DC
180/360/600 W 48 V DC
44 V DC± 4 V DC / 15 mA max.
Potential free, floating signal contact
Active output signal
Max. limiting average on state current [A]
Type\Temp.
1 ph 12 V / 6 A
1 ph 12 V / 12 A
1 ph 24 V / 3.8 A
1 ph 24 V / 7.5 A
1 ph 24 V / 15 A
1 ph 24 V / 25 A
1 ph 36 V / 16.5 A
1 ph 48 V / 2 A
1 ph 48 V / 4 A
1 ph 48 V / 7.5 A
1 ph 48 V / 12.5 A
1-2 ph 24 V / 7.5 A
1-2 ph 24 V / 15 A
1-2 ph 24 V / 25 A
40 °C
6.0
12.0
3.8
7.5
15.0
25.0
16.5
2.0
4.0
7.5
12.5
7.5
15.0
25.0
50 °C
5.7
9.5
3.1
6.3
12.5
22.5
15.0
1.6
3.3
6.3
11.3
6.3
12.5
22.5
60 °C
5.4
7.0
2.5
5.0
10.0
20.0
13.3
1.3
2.5
5.0
10.0
5.0
10.0
20.0
70 °C
4.5
3.7
1.7
3.3
6.7
13.3
9.0
0.8
1.7
3.3
7.5
3.3
6.7
13.3
EMC / shock / vibration
Noise emission acc. to EN55022
Noise immunity tests acc. to
Class B
EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields),
EN61000-4-4 (Burst), EN61000-4-5 (Surge),
EN610004-6 (conducted), EN61000-4-11 (Dips)
according to EN61000-3-2
3 axes, sinus, 10 – 55 Hz, 1 g, 1 oct./min.
3 axes, 15 g, half sinus, 11 ms
Limiting of mains voltage harmonic currents
Vibration IEC 60068-2-6
Shock IEC 60068-2-27
Electrical safety (applied standards)
Electrical equipment of machines
Safety transformers for switched-mode power units
Machinery with electronic equipment
Safety extra low voltage
according to EN60204
according to EN61558-2-4
according to EN50178
SELV according to EN60950
CP T SNT...
100
100
90
600 W
80
70
90 W
180 W
360 W
60
50
40
-25
40
50
Temperature [°C]
A.16
70 W
140 W
60
70
Output Power [% Pmax]
Output Power [% Pmax]
90
80
70
60
50
40
85 90 100 110 115
132
187
230 264
Input Voltage [VAC]
1366860000 – 2013
connectPower PRO-H
CP T SNT 70 W 12 V 6 A
Switch-mode power supplies
connectPower PRO-H
CP T SNT 140 W 12 V 12 A
A
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / making current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Height x width x depth
Weight
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Stripping length, rated connection
Wire cross-section, AWG/kcmil min/max
Note
mm²
100...240 V AC (wide-range input)
85...264 V AC
47...63 Hz
1 A @ 230 V AC, 2 A @ 115 V AC
4 A / < 20 A (230 V AC)
6…16 A, char. B, circuit breaker
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
1.4 A @ 230 V AC, 2.5 A @ 115 V AC
4 A / < 20 A (230 V AC)
6…16 A, char. B, circuit breaker
12 V DC ± 1 %
12...14 V DC (adjustable via potentiometer on front)
100 mVSS @ 12 V DC, Inom
6 A @ 40 °C
6 A @ 40 °C, 5.4 A @ 60 °C, 4.5 A @ 70 °C
12 V DC ± 1 %
12...14 V DC (adjustable via potentiometer on front)
100 mVSS @ 12 V DC, Inom
12 A @ 40 °C
12 A @ 40 °C, 7 A @ 60 °C, 3.7 A @ 70 °C
typ. 82 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 35 / 110 mm
0.5 kg
typ. 85 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 54 / 110 mm
0.7 kg
BVATEX; CE; CSA; cURus; GOSTME25; UL
BVATEX; CE; CSA; cURus; GOSTME25; UL
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
7 mm
24 / 12
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
7 mm
24 / 12
Output
Screw connection
2 (+ / -)
1 / 2.5
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
Ordering data
Type
CP T SNT 70W 12V 6A
Qty.
1
Order No.
1105430000
Type
CP T SNT 140W 12V 12A
Qty.
1
Order No.
1105440000
Note
Accessories
Note
1366860000 – 2013
A.17
Switch-mode power supplies
connectPower PRO-H
connectPower PRO-H
CP T SNT 90 W 24 V 3,8 A
CP T SNT 90 W 24 V 3,8 A CL2
Class 2, UL1310
A
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / making current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Height x width x depth
Weight
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Stripping length, rated connection
Wire cross-section, AWG/kcmil min/max
Note
100...240 V AC (wide-range input)
85...264 V AC
47...63 Hz
1 A @ 230 V AC, 2.1 A @ 115 V AC
4 A / < 20 A (230 V AC)
6…16 A, char. B, circuit breaker
100...240 V AC (wide-range input)
85...264 V AC
47...63 Hz
1 A @ 230 V AC, 2.1 A @ 115 V AC
4 A / < 20 A (230 V AC)
6…16 A, char. B, circuit breaker
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
3.8 A @ 40 °C
3.8 A @ 40 °C, 2.5 A @ 60 °C, 1.7 A @ 70 °C
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
3.8 A @ 40 °C
3.8 A @ 40 °C, 2.5 A @ 60 °C, 1.7 A @ 70 °C
typ. 85 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 35 / 110 mm
0.5 kg
typ. 85 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 35 / 110 mm
0.5 kg
BVATEX; CE; CSA; cURus; GOSTME25; UL
mm²
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
7 mm
24 / 12
Output
Screw connection
2 (+ / -)
1 / 2.5
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
7 mm
24 / 12
Output
Screw connection
2 (+ / -)
1 / 2.5
Ordering data
Type
CP T SNT 90W 24V 3,8A
Qty.
1
Order No.
1105790000
Type
CP T SNT 90W 24V3,8ACL2
Qty.
1
Order No.
1194410000
Note
Accessories
Note
A.18
1366860000 – 2013
connectPower PRO-H
CP T SNT 180 W 24 V 7,5 A
Switch-mode power supplies
connectPower PRO-H
CP T SNT 360 W 24 V 15 A
A
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / making current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Height x width x depth
Weight
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Stripping length, rated connection
Wire cross-section, AWG/kcmil min/max
Note
mm²
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
1.4 A @ 230 V AC, 2.5 A @ 115 V AC
4 A / < 20 A (230 V AC)
6…16 A, char. B, circuit breaker
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
2.5 A @ 230 V AC, 5 A @ 115 V AC
6.3 A / < 25 A (230 V AC)
10…16 A, char. B, circuit breaker
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
7.5 A @ 40 °C
7.5 A @ 40 °C, 5 A @ 60 °C, 3.3 A @ 70 °C
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
15 A @ 40 °C
15 A @ 40 °C, 10 A @ 60 °C, 6.7 A @ 70 °C
typ. 88 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 54 / 110 mm
0.7 kg
typ. 87 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 80 / 110 mm
1.1 kg
BVATEX; CE; CSA; cURus; GOSTME25; UL
BVATEX; CE; CSA; cURus; GOSTME25; UL
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
7 mm
24 / 12
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
7 mm
24 / 12
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
Ordering data
Type
CP T SNT 180W 24V 7,5A
Qty.
1
Order No.
1105810000
Type
CP T SNT 360W 24V 15A
Qty.
1
Order No.
1105820000
Note
Accessories
Note
1366860000 – 2013
A.19
Switch-mode power supplies
connectPower PRO-H
connectPower PRO-H
CP T SNT 600 W 24 V 25 A
CP T SNT 600 W 36 V 16,5 A
A
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / making current
Recommended back-up fuse
Output
Rated output voltage
Outpu voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Height x width x depth
Weight
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Stripping length, rated connection
Wire cross-section, AWG/kcmil min/max
Note
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
5 A @ 230 V AC, 10 A @ 115 V AC
12 A / < 30 A (230 V AC)
16…25 A, char. B, circuit breaker
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
1 A @ 230 V AC, 2 A @ 115 V AC
12 A / < 30 A (230 V AC)
16…25 A, char. B, circuit breaker
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
25 A @ 40 °C
25 A @ 40 °C, 20 A @ 60 °C, 13.3 A @ 70 °C
36 V DC ± 1 %
36...42 V DC (adjustable via potentiometer on front)
100 mVSS @ 36 V DC, Inom
16.5 A @ 40 °C
16.5 A @ 40 °C, 13.3 A @ 60 °C, 9 A @ 70 °C
typ. 89 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
125 / 165 / 125 mm
2.8 kg
typ. 87 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
125 / 165 / 125 mm
2.8 kg
BVATEX; CE; CSA; cURus; GOSTME25; UL
mm²
Input
Screw connection
3 for L/N/PE
1/4
7 mm
18 / 10
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
Input
Screw connection
3 for L/N/PE
1/4
7 mm
18 / 10
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
Ordering data
Type
CP T SNT 600W 24V 25A
Qty.
1
Order No.
1105840000
Type
CP T SNT 600W 36V 16,5A
Qty.
1
Order No.
1194430000
Note
Accessories
Note
A.20
1366860000 – 2013
connectPower PRO-H
CP T SNT 90 W 48 V 2 A
Switch-mode power supplies
connectPower PRO-H
CP T SNT 180 W 48 V 4 A
A
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / making current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Height x width x depth
Weight
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Stripping length, rated connection
Wire cross-section, AWG/kcmil min/max
Note
100...240 V AC (wide-range input)
85...264 V AC
47...63 Hz
1 A @ 230 V AC, 2.1 A @ 115 V AC
4 A / < 20 A (230 V AC)
6…16 A, char. B, circuit breaker
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
1.4 A @ 230 V AC, 2.5 A @ 115 V AC
4 A / < 25 A (230 V AC)
6…16 A, char. B, circuit breaker
48 V DC ± 1 %
48...56 V DC (adjustable via potentiometer on front)
100 mVSS @ 48 V DC, INenn
2 A @ 40 °C
2 A @ 40 °C, 1.3 A @ 60 °C, 0.8 A @ 70 °C
48 V DC ± 1 %
48...56 V DC (adjustable via potentiometer on front)
100 mVSS @ 48 V DC, INenn
4 A @ 40 °C
4 A @ 40 °C, 2.5 A @ 60 °C, 1.7 A @ 70 °C
typ. 87 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 35 / 110 mm
0.5 kg
typ. 90 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 54 / 110 mm
0.7 kg
BVATEX; CSA; cURus; GOSTME25; UL
mm²
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
7 mm
24 / 12
Output
Screw connection
2 (+ / -)
1 / 2.5
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
7 mm
24 / 12
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
Ordering data
Type
CP T SNT 90W 48V 2A
Qty.
1
Order No.
1194420000
Type
CP T SNT 180W 48V 4A
Qty.
1
Order No.
1105850000
Note
Accessories
Note
1366860000 – 2013
A.21
Switch-mode power supplies
connectPower PRO-H
connectPower PRO-H
CP T SNT 360 W 48V 7,5 A
CP T SNT 600 W 48 V 12,5 A
A
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / making current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Height x width x depth
Weight
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Stripping length, rated connection
Wire cross-section, AWG/kcmil min/max
Note
mm²
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
2.5 A @ 230 V AC, 5 A @ 115 V AC
6.3 A / < 25 A (230 V AC)
10…16 A, char. B, circuit breaker
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
5 A @ 230 V AC, 10 A @ 115 V AC
12 A / < 30 A (230 V AC)
16…25 A, char. B, circuit breaker
48 V DC ± 1 %
48...56 V DC (adjustable via potentiometer on front)
100 mVSS @ 48 V DC, INenn
7.5 A @ 40 °C
7.5 A @ 40 °C, 5 A @ 60 °C, 3.3 A @ 70 °C
48 V DC ± 1 %
48...56 V DC (adjustable via potentiometer on front)
100 mVSS @ 48 V DC, INenn
12.5 A @ 40 °C
12.5 A @ 40 °C, 10 A @ 60 °C, 7.5 A @ 70 °C
typ. 89 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 80 / 110 mm
1.1 kg
typ. 91 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
125 / 165 / 125 mm
2.8 kg
BVATEX; CSA; cURus; GOSTME25; UL
BVATEX; CSA; cURus; GOSTME25; UL
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
7 mm
24 / 12
Input
Screw connection
3 for L/N/PE
1/4
7 mm
18 / 10
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
Ordering data
Type
CP T SNT 360W 48V 7,5A
Qty.
1
Order No.
1105860000
Type
CP T SNT 600W 48V 12,5A
Qty.
1
Order No.
1105870000
Note
Accessories
Note
A.22
1366860000 – 2013
connectPower PRO-H
CP T SNT2 180 W 24 V 7,5 A
Switch-mode power supplies
connectPower PRO-H
CP T SNT2 360 W 24 V 15 A
A
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / making current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Height x width x depth
Weight
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Stripping length, rated connection
Wire cross-section, AWG/kcmil min/max
Note
100…500 V AC (switchable)
85…132 V AC, 187…550 V AC
50 / 60 Hz
100…500 V AC (switchable)
85…132 V AC, 187…550 V AC
50 / 60 Hz
/ < 23 A @ 230 V AC
mm²
/ < 23 A @ 230 V AC
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
7.5 A @ 40 °C
7.5 A @ 40 °C, 5 A @ 60 °C, 3.3 A @ 70 °C
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
15 A @ 40 °C
15 A @ 40 °C, 10 A @ 60 °C, 6.7 A @ 70 °C
typ. 88 %
typ. 88 %
Yes
110 / 54 / 110 mm
0.7 kg
Yes
125 / 80 / 125 mm
1.1 kg
Input
Screw connection
3 for L/N/PE
1/4
7 mm
18 / 10
Output
Screw connection
2/4
12 / 10
Input
Screw connection
3 for L/N/PE
1/4
7 mm
18 / 10
Output
Screw connection
2/4
12 / 10
Ordering data
Type
CP T SNT2 180 W 24 V 7,5 A
Qty.
1
Order No.
1194480000
Type
CP T SNT2 360 W 24 V 15 A
Qty.
1
Order No.
1194490000
Note
Accessories
Note
1366860000 – 2013
A.23
Switch-mode power supplies
connectPower PRO-H
connectPower PRO-H
CP T SNT2 600 W 24 V 25 A
A
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / making current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Height x width x depth
Weight
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Stripping length, rated connection
Wire cross-section, AWG/kcmil min/max
Note
100…500 V AC (switchable)
85…132 V AC, 187…550 V AC
50 / 60 Hz
/ < 50 A @ 230 V AC
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
25 A @ 40 °C
25 A @ 40 °C, 20 A @ 40 °C, 13.3 A @ 70 °C
typ. 88 %
min. 20 ms
Yes
125 / 190 / 125 mm
3 kg
mm²
Input
Screw connection
3 for L/N/PE
1/4
7 mm
18 / 10
Output
Screw connection
5 (++ / ---)
2/4
12 / 10
Ordering data
Type
CP T SNT2 600 W 24 V 25 A
Qty.
1
Order No.
1194310000
Note
Accessories
Note
A.24
1366860000 – 2013
connectPower PRO-H
CP T RM 10
Switch-mode power supplies
connectPower PRO-H
CP T RM 20
A
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / making current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Height x width x depth
Weight
Approvals
Approvals
Connection data
Conductor connection system
Number of terminals
Wire cross-section, rigid min/max
Stripping length, rated connection
Wire cross-section, AWG/kcmil min/max
Note
mm²
24 V DC
24 V DC
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
15 A @ 40 °C
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
25 A @ 40 °C
110 / 35 / 110 mm
0.4 kg
110 / 54 / 110 mm
0.45 kg
CSA; cURus; GOSTME25
CE; CSA; cURus; GOSTME25
Input
Output
Input
Output
4 (++--)
1/4
mm
18 / 10
4 (++ / --)
2/4
4 (++--)
1/4
mm
18 / 10
4 (++ / --)
2/4
12 / 10
12 / 10
Ordering data
Type
CP T RM 10
Qty.
1
Order No.
1105880000
Type
CP T RM 20
Qty.
1
Order No.
1105890000
Note
Accessories
Note
1366860000 – 2013
A.25
38.5 (1.52)
Output
Inputs ON
DC 24V / 25 A
Inputs ON
DC IN 1
(0.98)
5.0
(0.20)
14.5
(0.57)
CP T RM 20
35.0 (1.38)
54.0 (2.13)
38.5 (1.52)
110.0 (4.33)
DC OK
DC ON
DC ON
80.0 (3.15)
L
25.0
(0.98)
5.0
5.0
(0.20)
(0.20)
5.0
110.0 (4.33)
80.0 (3.15)
110.0 (4.33)
25.0
(0.20)
PE N
L
(0.98)
DC OK
O/P ADJ.
O/P ADJ.
PE N
110.0 (4.33)
38.5 (1.52)
CP T RM 10
DC IN 2
25.0
(0.20)
5.0
(0.98)
5.0
24 – 27 V
- +
25.0
(0.20)
110.0 (4.33)
24 – 27 V
DC IN 1 DC IN 2
110.0 (4.33)
80.0 (3.15)
- - + +
- +
54.0 (2.13)
110.0 (4.33)
38.5 (1.52)
35.0 (1.38)
80.0 (3.15)
A
PRO-H Dimensional drawings
110.0 (4.33)
Switch-mode power supplies
connectPower PRO-H
14.5
(0.57)
P/ S
CP T SNT 70 W / 90 W
A.26
Remote
S P
P S
Remote
P/ S
CP T SNT 180 W / 140 W
1366860000 – 2013
Switch-mode power supplies
connectPower PRO-H
PRO-H Dimensional drawings
80.0 (3.15)
45.0(1.77)
125.0 (4.92)
DC OK
DC ON
O/P ADJ.
P/ S Remote
A
86.5(3.41)
125.0 (4.92)
P S
PE N L
25.0
25.0
(0.98)
46.0
17.0
25.0
21.0
(4.84)
(0.83)
(0.67)
165.0 (6.50)
25.0
125.0 (4.92)
(0.98)
PE
N
L
DC OK
DC ON
O/ P ADJ.
86.5 (3.41)
125.0 (4.92)
45.0 (1.77)
5.0
(0.20)
(1.81)
(0.98)
(0.98)
123.0
Remote
P S
P/ S
CP T SNT 360 W / 480 W
1366860000 – 2013
CP T SNT 600 W / 960 W
A.27
Switch-mode power supplies
ECOLINE
connectPower single-phase
CP SNT 70 W 24 V 3 A
H
A
W
D
Vin AC
L
AC/DC
N
PWM
EMC
Filter
Rectifier
+
Flyback
Converter
Output Recctifier
& Filter
V out DC
Output Current
Check & Share
current control
Feedback
DC
OVP, OTP
–
12
Signal Relay
11
14
Technical data
85...264 V AC / 110...370 V DC
2 A @ 100...240 V AC
50/ 60 Hz
Fusible link 2.5 A (T) / 250 V
Varistor
24...28 V DC (adjustable via potentiometer)
3A
72 W
< 100 mVPP / bandwidth 20 MHz
105 %..130 % Iconst of max. output load; automatic reset
4
3.5
3
2.5
2
1.5
1
0.5
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
29...34 V
10 ms @ 115 V AC / 20 ms @ 230 V AC
<2%
Recommended with diode module
250 V AC (max. 30 V DC) / 1 A
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Status relay / CO contact
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
General data
Ambient temperature
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Mounting position, installation notice
Installation advice
Weight
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
Current (A)
Derating curve
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
0.5 kV
1.5 kV
3 kV
-10 °C+70 °C (Derating ab 55 °C)
-20 °C...+85 °C
80%
Green LED
DIN EN 60950 (SELV)
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
horizontally, on terminal rail TS 35
Clearance: above/below ≥ 3 cm
0.55 kg
CE; cULus; cURus; GL; GOSTME25
mm²
Input/Output
2.5 / 0.13 / 4
125 / 55.5 / 110 mm
For redundancy operation or to maintain the alert function, only operate with
the diode module.
Ordering data
Screw connection
Note
Type
CP SNT 70W 24V 3A
Qty.
1
Order No.
8708660000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
A.28
1366860000 – 2013
connectPower single-phase
Switch-mode power supplies
ECOLINE
CP SNT 120 W 24 V 5 A
H
A
W
D
V IN AC
L
AC/DC
N
PWM
EMC &
Filter
Forward
Converter
Rectifier
& Filter
+
PWM
Controller
DC
–
V OUT DC
Out Rectifier
& Filter
Photocoupler
Voltage
feedback
Photocoupler
OVP
Signal
Relay
12
11
14
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
88...132 V AC/176...264 V AC selectable; 250...370 V DC
3 A @ 115 V AC / 2 A @ 230 V AC
50/ 60 Hz
Fusible link 4 A (T) / 250 V
Varistor
24...28 V DC (adjustable via potentiometer)
5A
120 W
< 100 mVPP / bandwidth 20 MHz
105 %..130 % Iconst of max. output load; automatic reset
29...34 V
20 ms @ 115 V AC / 20 ms @ 230 V AC
<2%
Recommended with diode module
250 V AC (max. 30 V DC) / 1 A
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Status relay / CO contact
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
General data
Ambient temperature
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Mounting position, installation notice
Installation advice
Weight
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
0.5 kV
1.5 kV
3 kV
-10 °C+70 °C (Derating ab 55 °C)
-20 °C...+85 °C
84%
Green LED
DIN EN 60950 (SELV)
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
horizontally, on terminal rail TS 35
Clearance: above/below ≥ 3 cm
0.65 kg
CE; cULus; cURus; GL; GOSTME25
mm²
Input/Output
2.5 / 0.13 / 4
125 / 65.5 / 110 mm
For redundancy operation or to maintain the alert function, only operate with
the diode module.
Ordering data
Screw connection
Note
Type
CP SNT 120W 24V 5A
Qty.
1
Order No.
8708670000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
1366860000 – 2013
A.29
connectPower single-phase
CP SNT 250 W 24 V 10 A
H
A
W
D
VIN AC
L
AC/DC
N
PWM
EMC
Input
Rectifier
& Filter
+
Output
Rectifier
& Filter
Forward
Converter
VOUT DC
PWM
Control
DC
Photocoupler
–
Feedback
Signal
Relay
12
11
14
Technical data
Derating curve
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
88...132 V AC/176...264 V AC selectable; 250...370 V DC
3.6 A @ 115 V AC / 2 A @ 230 V AC
50/ 60 Hz
Fusible link 5 A (T) / 250 V
Varistor
24...28 V DC (adjustable via potentiometer)
0.1…10 A
240 W
< 100 mVPP / bandwidth 20 MHz
105 %..130 % Iconst of max. output load; automatic reset
10
8
6
4
2
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
30...36 V
10 ms @ 115 V AC / 15 ms @ 230 V AC
<2%
Recommended with diode module
250 V AC (max. 30 V DC) / 1 A
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Status relay / CO contact
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
General data
Ambient temperature
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Mounting position, installation notice
Installation advice
Weight
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
12
Current (A)
Switch-mode power supplies
ECOLINE
0.5 kV
1.5 kV
3 kV
-10 °C+70 °C (Derating ab 55 °C)
-20 °C...+85 °C
84% @ 230 V AC
Green LED
DIN EN 60950 (SELV)
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
horizontally, on terminal rail TS 35
Clearance: above/below ≥ 3 cm
1.6 kg
CE; cULus; cURus; GL; GOSTME25
mm²
Input/Output
4 / 0.13 / 6
125 / 125.5 / 110 mm
For redundancy operation or to maintain the alert function, only operate with
the diode module.
Ordering data
Screw connection
Note
Type
CP SNT 250W 24V 10A
Qty.
1
Order No.
8708680000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
A.30
1366860000 – 2013
connectPower single-phase
Switch-mode power supplies
ECOLINE
CP SNT 500 W 24 V 20 A
H
A
W
D
VIN AC
L
AC/DC
N
PWM
EMI
Input
Rectiefier
& Filter
Forward
Converter
Output
Rectifier
& Filter
PWM
Feedback
VOUT DC
+
DC
–
Signal
Relay
12
11
14
Technical data
Derating curve
88...132 V AC/176...264 V AC selectable; 250...370 V DC
9 A @ 115 V AC / 6 A @ 230 V AC
50/ 60 Hz
Fusible link 10 A (T) / 250 V
Varistor
24...28 V DC (adjustable via potentiometer)
2...20 A @ 200...240 V AC; 2...16 A @ 100...120 V AC
480 W
< 100 mVPP / bandwidth 20 MHz
105 %..130 % Iconst of max. output load; automatic reset
20
10
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
30...36 V
10 ms @ 115 V AC / 15 ms @ 230 V AC
<2%
Recommended with diode module
250 V AC (max. 30 V DC) / 1 A
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Status relay / CO contact
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
General data
Ambient temperature
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Mounting position, installation notice
Installation advice
Weight
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
30
Current (A)
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
0.5 kV
1.5 kV
3 kV
-10 °C+70 °C (Derating ab 55 °C)
-20 °C...+85 °C
86%
Green LED
DIN EN 60950 (SELV)
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
horizontally, on terminal rail TS 35
Clearance: above/below ≥ 3 cm
2 kg
CE; cULus; cURus; GL; GOSTME25; TUEV
mm²
Input/Output
4 / 0.13 / 6
125 / 227.5 / 110 mm
For redundancy operation or to maintain the alert function, only operate with
diode module.
Ordering data
Screw connection
Note
Type
CP SNT 500W 24V 20A
Qty.
1
Order No.
8778870000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
1366860000 – 2013
A.31
connectPower single-phase
CP SNT 1000 W 24 V 40 A
H
A
W
D
V IN AC
L
AC/DC
N
PWM
EMC &
Filter
Rectifier
& Filter
+
Forward
Converter
PWM
Controller
DC
–
V OUT DC
Out Rectifier
& Filter
Photocoupler
Voltage
feedback
Photocoupler
OVP
Signal
Relay
12
11
14
Technical data
Derating curve
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
85…264 V AC
12 A @ 115 V AC; 4.8 A @ 230 V AC
50/ 60 Hz
Fusible link 15 A (T) / 250 V
Varistor
40
24...28 V DC (adjustable via potentiometer)
40 A
960 W
< 100 mVPP / bandwidth 20 MHz
105 %...125 % Iconst of max. output load; automatic reset
30
20
10
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
29...34 V
20 ms @ 115 V AC / 20 ms @ 230 V AC
<2%
Recommended with diode module
250 V AC (max. 30 V DC) / 1 A
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Status relay / CO contact
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
General data
Ambient temperature
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Mounting position, installation notice
Installation advice
Weight
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
50
Current (A)
Switch-mode power supplies
ECOLINE
0.5 kV
1.5 kV
3 kV
-10 °C+70 °C (Derating ab 55 °C)
-20 °C...+85 °C
89%
Green LED
DIN EN 60950 (SELV)
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
horizontally, on terminal rail TS 35
Clearance: above/below ≥ 3 cm
4.4 kg
CE; cURus; GOSTME25
mm²
Input/Output
4 / 0.13 / 6
150 / 240 / 125 mm
For redundancy operation or to maintain the alert function, only operate with
diode module.
Ordering data
Screw connection
Note
Type
CP SNT 1000W 24V 40A
Qty.
1
Order No.
8862780000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
A.32
1366860000 – 2013
connectPower 3-phase
Switch-mode power supplies
ECOLINE
CP SNT3 120 W 24 V 5 A
H
A
W
V IN AC
L1
AC L2
L3
PWM
EMC &
Filter
Forward
Converter
Rectifier
& Filter
+
PWM
Controller
DC
–
V OUT DC
Out Rectifier
& Filter
Photocoupler
Voltage
feedback
Photocoupler
OVP
Signal
Relay
12
11
14
Technical data
Derating curve
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
3x400 V AC / 400...500 V AC ±15 %
0.8 A @ 400 V AC
47...63 Hz
External via 3 circuit-breakers up to 6...16 A, char. C
Varistor
5
24...28 V DC (adjustable via potentiometer)
5A
120 W
< 100 mVPP / bandwidth 20 MHz
105 %..130 % Iconst of max. output load; automatic reset
4
3
2
1
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
29...34 V
> 20 ms @ 400 V AC
<2%
Recommended with diode module
250 V AC (max. 30 V DC) / 1 A
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Status relay / CO contact
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
General data
Ambient temperature
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Mounting position, installation notice
Installation advice
Weight
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
6
Current (A)
D
0.5 kV
1.5 kV
3 kV
-10 °C+70 °C (Derating ab 55 °C)
-20 °C...+85 °C
85% @ 400 V AC
Green LED
DIN EN 60950 (SELV)
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
horizontally, on terminal rail TS 35
Clearance: above/below ≥ 3 cm
1.5 kg
cURus; GOSTME25; UL
mm²
Input/Output
4 / 0.13 / 4
125 / 90 / 110 mm
For redundancy operation or to maintain the alert function, only operate with
the diode module.
Ordering data
Screw connection
Note
Type
CP SNT3 120W 24V 5A
Qty.
1
Order No.
8862730000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
1366860000 – 2013
A.33
connectPower 3-phase
CP SNT3 250 W 24 V 10 A
H
A
W
D
3ph VIN AC
L1
AC L2
L3
PWM
VOUT DC
AC/DC
Converter
+
DC
Output
Voltage
control
Anti Surge
Circuit
–
Output Current
Check & Control
R SENSE
OCP
Output
Current
Protection
OTP/OVP
Output
Voltage
Protection
Signal
Relay
12
11
14
Technical data
Derating curve
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
3x400 V AC / 400...500 V AC ±15 %
0.95 A @ 400 V AC
47...63 Hz
External via 3 circuit-breakers up to 2…3 A, char. C
Varistor
10
24...28 V DC (adjustable via potentiometer)
10 A
250 W
< 100 mVPP / bandwidth 20 MHz
105 %..130 % Iconst of max. output load; automatic reset
8
6
4
2
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
29...34 V
> 10 ms @ 400 V AC
<2%
Recommended with diode module
250 V AC (max. 30 V DC) / 1 A
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Status relay / CO contact
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
General data
Ambient temperature
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Mounting position, installation notice
Installation advice
Weight
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
12
Current (A)
Switch-mode power supplies
ECOLINE
0.5 kV
1.5 kV
3 kV
-10 °C+70 °C (Derating ab 55 °C)
-20 °C...+85 °C
88% @ 400 V AC
Green LED
DIN EN 60950 (SELV)
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
horizontally, on terminal rail TS 35
Clearance: above/below ≥ 3 cm
1.5 kg
CE; cULus; cURus; GL; GOSTME25
mm²
Input/Output
4 / 0.13 / 6
125 / 125.5 / 110 mm
For redundancy operation or to maintain the alert function, only operate with
diode module.
Ordering data
Screw connection
Note
Type
CP SNT3 250W 24V 10A
Qty.
1
Order No.
8708700000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
A.34
1366860000 – 2013
connectPower 3-phase
Switch-mode power supplies
ECOLINE
CP SNT3 500 W 24 V 20 A
H
A
W
3ph VIN AC
L1
AC L2
L3
PWM
VOUT DC
AC/DC
Converter
+
DC
Output
Voltage
control
Anti Surge
Circuit
–
Output Current
Check & Control
R SENSE
OCP
Output
Current
Protection
OTP/OVP
Output
Voltage
Protection
Signal
Relay
12
11
14
Technical data
Derating curve
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
3x400 V AC / 400...500 V AC ±15 %
1.7 A @ 400 V AC
47...63 Hz
External via 3 circuit-breakers up to 3…6 A, char. C
Varistor
25
24...28 V DC (adjustable via potentiometer)
20 A
480 W
< 100 mVPP / bandwidth 20 MHz
105 %..130 % Iconst of max. output load; automatic reset
20
15
10
5
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
30...34 V
> 10 ms @ 400 V AC
<2%
Recommended with diode module
250 V AC (max. 30 V DC) / 1 A
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Status relay / CO contact
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
General data
Ambient temperature
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Mounting position, installation notice
Installation advice
Weight
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
30
Current (A)
D
0.5 kV
1.5 kV
3 kV
-10 °C+70 °C (Derating ab 55 °C)
-20 °C...+85 °C
88%
Green LED
DIN EN 60950 (SELV)
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
horizontally, on terminal rail TS 35
Clearance: above/below ≥ 3 cm
3 kg
CE; cULus; cURus; GL; GOSTME25
mm²
Input/Output
4 / 0.13 / 6
125 / 227.5 / 110 mm
For redundancy operation or to maintain the alert function, only operate with
diode module.
Ordering data
Screw connection
Note
Type
CP SNT3 500W 24V 20A
Qty.
1
Order No.
8708710000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
1366860000 – 2013
A.35
connectPower 3-phase
CP SNT3 1000 W 24 V 40 A
H
A
W
D
3ph VIN AC
L1
AC L2
L3
PWM
VOUT DC
AC/DC
Converter
+
DC
Output
Voltage
control
Anti Surge
Circuit
–
Output Current
Check & Control
R SENSE
OCP
Output
Current
Protection
OTP/OVP
Output
Voltage
Protection
Signal
Relay
12
11
14
Technical data
Derating curve
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
3x400 V AC / 400...500 V AC ±15 %
3.4 A @ 400 V AC
47...63 Hz
External via 3 circuit-breakers up to 6...16 A, char. C
Varistor
40
24...28 V DC (adjustable via potentiometer)
40 A
960 W
< 100 mVPP / bandwidth 20 MHz
105 %..130 % Iconst of max. output load; automatic reset
30
20
10
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
29...34 V
> 10 ms @ 400 V AC
<2%
Direct for same type
250 V AC (max. 30 V DC) / 1 A
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Status relay / CO contact
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
General data
Ambient temperature
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Mounting position, installation notice
Installation advice
Height x width x depth
Weight
Approvals
Dimensions
Clamping range (nominal / min. / max.)
50
Current (A)
Switch-mode power supplies
ECOLINE
0.5 kV
1.5 kV
3 kV
-10 °C+70 °C (Derating ab 55 °C)
-20 °C...+85 °C
88%
Green LED
DIN EN 60950 (SELV)
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
horizontally, on terminal rail TS 35
Clearance: above/below ≥ 3 cm
150 / 280 / 125 mm
3.5 kg
CE; GL; GOSTME25; UL
mm²
Note
Input
4 / 0.1 / 6
Output
10 / 0.3 / 16
For redundancy operation or to maintain the alert function, only operate with
diode module.
Ordering data
Screw connection
Note
Type
CP SNT3 1000W 24V 40A
Qty.
1
Order No.
8708730000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
A.36
1366860000 – 2013
connectPower diode module
CP DM 10
Switch-mode power supplies
ECOLINE
CP DM 20
H
A
W
D
+V
E1
E2
–V
–V
DC
E1 E2 –V
-V
+V
-V
+
+V –V
DC
–
E1
E2
-V
E1
E2
-V
Technical data
Input
Input voltage
Input current
Output
Output voltage
Output current
General data
Ambient temperature
Storage temperature
Degree of efficiency at max. load
Mounting position, installation notice
Installation advice
Height x width x depth
Weight
Approvals
Dimensions
Clamping range (nominal / min. / max.)
mm²
40 V DC max.
2 x 0...10 A max.
40 V DC max.
2 x 0...20 A max.
Uin - 0.5 V typical
0...20 A max. or 10 A max. for redundancy operation
Uin - 0.5 V typical
0...40 A max. or 20 A max. for redundant operations
-10 °C...+55 °C
-20 °C...+85 °C
95.5%
horizontally, on terminal rail TS 35
Clearance: side ≥ 2 cm; above/below ≥ 10 cm
125 / 55.5 / 110 mm
0.4 kg
CE; cULus; cURus
-10 °C...+55 °C
-20 °C...+85 °C
97.5%
horizontally, on terminal rail TS 35
Clearance: side ≥ 2 cm; above/below ≥ 10 cm
125 / 55.5 / 110 mm
0.4 kg
CE; cULus; cURus
Input
4 / 0.13 / 6
Input
4 / 0.13 / 6
Output
4 / 0.13 / 6
Output
10 / 0.32 / 16
Note
Ordering data
Screw connection
Type
CP DM 10
Qty.
1
Order No.
8710620000
Type
CP DM 20
Qty.
1
Order No.
8768650000
Note
Accessories
Note
1366860000 – 2013
A.37
Switch-mode power supplies
INSTAPOWER
connectPower single-phase
CP SNT 24 W 28 V 1 A
CP SNT 24 W 24 V 1 A
A
L
AC/DC
N
PWM
L
+
FUSE
N
DC
+
L
−
N
FUSE
+
−
–
Technical data
Input
Input voltage
Input current
Input frequency
Turn-on current limit
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Max. capacitance at output
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
Electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Standards
Approvals
EMC standards
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
mm²
85...265 V AC, 120...300 V DC
460 mA @ 115 V AC; 250 mA @ 230 V AC
50/ 60 Hz
Thermistor
2 A time-lag fuse (internal)
Varistor
85...265 V AC, 120...300 V DC
460 mA @ 115 V AC; 250 mA @ 230 V AC
50/ 60 Hz
Thermistor
2 A time-lag fuse (internal)
Varistor
28 V DC
1A
28 W
<2%
Surge current / thermal cut-out
24 V DC
1A
24 W
<2%
Surge current / thermal cut-out
Varistor
35 ms @ 115 V AC / 160 ms @ 230 V AC
0.5%
8000 µF
Varistor
35 ms @ 115 V AC / 160 ms @ 230 V AC
0.5%
8000 µF
0.5 kV
1.5 kV
3 kV
4 kV
0.5 kV
1.5 kV
3 kV
4 kV
-20...+50 °C
-40 °C...+85 °C
78%
DIN EN 50178, DIN EN 60950, IEC950
CE; CSA; GOSTME25
EN 61000-6 /-2, -3
-20...+50 °C
-40 °C...+85 °C
78%
DIN EN 50178, DIN EN 60950, IEC950
CE; CSA; CSAEX; GOSTME25
EN 61000-6 /-2, -3
Input/Output
4 / 0.08 / 4
90.5 / 52 / 62.5 mm
Input/Output
4 / 0.08 / 4
90.5 / 52 / 62.5 mm
Derating loss: 33% @ 60°C The internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Derating loss: 33% @ 60°C The internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Type
CP SNT 24W 28V 1A
Type
CP SNT 24W 24V 1A
Ordering data
Screw connection
Qty.
1
Order No.
9928890028
Qty.
1
Order No.
9928890024
Note
Accessories
Note
A.38
1366860000 – 2013
connectPower single-phase
CP SNT 24 W 15 V 1.5 A
Switch-mode power supplies
INSTAPOWER
CP SNT 24 W 12 V 1.5 A
A
L
AC/DC
N
PWM
L
+
FUSE
N
DC
+
L
−
N
FUSE
+
−
–
Technical data
Input
Input voltage
Input current
Input frequency
Turn-on current limit
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Max. capacitance at output
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
Electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Standards
Approvals
EMC standards
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
mm²
85...265 V AC, 120...300 V DC
460 mA @ 115 V AC; 250 mA @ 230 V AC
50/ 60 Hz
Thermistor
2 A time-lag fuse (internal)
Varistor
85...265 V AC, 120...300 V DC
460 mA @ 115 V AC; 250 mA @ 230 V AC
50/ 60 Hz
Thermistor
2 A time-lag fuse (internal)
Varistor
15 V DC
1.5 A
22.5 W
<2%
Surge current / thermal cut-out
12 V DC
1.5 A
18 W
<2%
Surge current / thermal cut-out
Varistor
35 ms @ 115 V AC / 160 ms @ 230 V AC
0.5%
8000 µF
Varistor
35 ms @ 115 V AC / 160 ms @ 230 V AC
0.5%
8000 µF
0.5 kV
1.5 kV
3 kV
4 kV
0.5 kV
1.5 kV
3 kV
4 kV
-20...+50 °C
-40 °C...+85 °C
78%
DIN EN 50178, DIN EN 60950, IEC950
CE; CSA; GOSTME25
EN 61000-6 /-2, -3
-20...+50 °C
-40 °C...+85 °C
78%
DIN EN 50178, DIN EN 60950, IEC950
CE; CSA; GOSTME25
EN 61000-6 /-2, -3
Input/Output
4 / 0.08 / 4
90.5 / 52 / 62.5 mm
Input/Output
4 / 0.08 / 4
90.5 / 52 / 62.5 mm
Derating loss: 33% @ 60°C The internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Derating loss: 33% @ 60°C The internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Type
CP SNT 24W 15V 1.5A
Type
CP SNT 24W 12V 1.5A
Ordering data
Screw connection
Qty.
1
Order No.
9928890015
Qty.
1
Order No.
9928890012
Note
Accessories
Note
1366860000 – 2013
A.39
Switch-mode power supplies
INSTAPOWER
connectPower single-phase
CP SNT 24 W 5 V 2 A
D
W
A
L
AC/DC
N
H
PWM
L
+
FUSE
+
−
N
DC
–
Technical data
Input
Input voltage
Input current
Input frequency
Turn-on current limit
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
85...265 V AC, 120...300 V DC
460 mA @ 115 V AC; 250 mA @ 230 V AC
50/ 60 Hz
Thermistor
2 A time-lag fuse (internal)
Varistor
5 V DC
2A
10 W
<2%
Surge current / thermal cut-out
Varistor
35 ms @ 115 V AC / 160 ms @ 230 V AC
0.5%
8000 µF
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Max. capacitance at output
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
Electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Standards
Approvals
EMC standards
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
0.5 kV
1.5 kV
3 kV
4 kV
-20...+50 °C
-40 °C...+85 °C
78%
DIN EN 50178, DIN EN 60950, IEC950
CE; CSA; GOSTME25
EN 61000-6 /-2, -3
mm²
Input/Output
4 / 0.08 / 4
90.5 / 52 / 62.5 mm
Derating loss: 33% @ 60°C The internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Ordering data
Screw connection
Type
CP SNT 24W 5V 2A
Qty.
1
Order No.
9928890005
Note
Accessories
Note
A.40
1366860000 – 2013
connectPower single-phase
Switch-mode power supplies
INSTAPOWER
CP SNT 25 W 5 V 5 A
D
W
L
AC/DC
N
A
H
PWM
L
+
FUSE
+
−
N
DC
–
Technical data
Derating curve
Input
Input voltage
Input current
Input frequency
Turn-on current limit
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
85...264 V AC / 110...370 V DC
500 mA at rated load @ 230 V AC
50/ 60 Hz
Yes
Fusible link 2.5 A (T) / 250 V
Current (A)
5
4...8 V DC (adjustable via potentiometer)
5A
25 W
120 mVSS
105 %...150 % Iconst of max. output load; automatic reset
4
3
2
1
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
Varistor
11 ms @ 115 V AC / 50 ms @ 230 V AC
1%
10000 µF
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Max. capacitance at output
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
Electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Standards
Approvals
EMC standards
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
6
0.5 kV
1.5 kV
3 kV
4 kV
-10...+70 °C (Derating ab 55 °C)
-20 °C...+85 °C
70%
DIN EN 50178 (PELV), DIN EN 60950 (SELV)
cCSAus; cURus; GOSTME25; UL
EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4
mm²
Input/Output
2.5 / 0.5 / 4
90.5 / 70 / 62.5 mm
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Ordering data
Screw connection
Type
CP SNT 25W 5V 5A
Qty.
1
Order No.
8754960000
Note
Accessories
Note
1366860000 – 2013
A.41
Switch-mode power supplies
INSTAPOWER
connectPower single-phase
CP SNT 48 W 12 V 4 A
D
W
A
L
AC/DC
N
H
PWM
L
+
FUSE
+
−
N
DC
–
Technical data
Derating curve
Input
Input voltage
Input current
Input frequency
Turn-on current limit
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
85...264 V AC / 110...370 V DC
500 mA at rated load @ 230 V AC
50/ 60 Hz
Yes
Fusible link 2.5 A (T) / 250 V
Current (A)
5
9...15 V DC (adjustable via potentiometer)
4A
48 W
120 mVSS
105 %...150 % Iconst of max. output load; automatic reset
4
3
2
1
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
Varistor
11 ms @ 115 V AC / 50 ms @ 230 V AC
1%
10000 µF
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Max. capacitance at output
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
Electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Standards
Approvals
EMC standards
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
6
0.5 kV
1.5 kV
3 kV
4 kV
-10...+70 °C (Derating ab 55 °C)
-20 °C...+85 °C
75%
DIN EN 50178 (PELV), DIN EN 60950 (SELV)
cCSAus; CE; cULus; cURus; GOSTME25; UL
EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4
mm²
Input/Output
2.5 / 0.5 / 4
90.5 / 70 / 62.5 mm
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Ordering data
Screw connection
Type
CP SNT 48W 12V 4A
Qty.
1
Order No.
8754970000
Note
Accessories
Note
A.42
1366860000 – 2013
connectPower single-phase
Switch-mode power supplies
INSTAPOWER
CP SNT 48 W 24 V 2 A
D
W
L
AC/DC
N
A
H
PWM
L
+
FUSE
+
−
N
DC
–
Technical data
Derating curve
Input
Input voltage
Input current
Input frequency
Turn-on current limit
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
85...264 V AC / 110...370 V DC
500 mA at rated load @ 230 V AC
50/ 60 Hz
Yes
Fusible link 2.5 A (T) / 250 V
Current (A)
15...28 V DC (adjustable via potentiometer)
2A
48 W
120 mVSS
105 %...150 % Iconst of max. output load; automatic reset
2
1.5
1
0.5
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
Varistor
11 ms @ 115 V AC / 50 ms @ 230 V AC
1%
10000 µF
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Max. capacitance at output
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
Electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Standards
Approvals
EMC standards
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
3
2.5
0.5 kV
1.5 kV
3 kV
4 kV
-10...+70 °C (Derating ab 55 °C)
-20 °C...+85 °C
78%
DIN EN 50178 (PELV), DIN EN 60950 (SELV)
cCSAus; cULus; cURus; GOSTME25; UL
EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4
mm²
Input/Output
2.5 / 0.5 / 4
90.5 / 70 / 62.5 mm
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Ordering data
Screw connection
Type
CP SNT 48W 24V 2A
Qty.
1
Order No.
8739140000
Note
Accessories
Note
1366860000 – 2013
A.43
Switch-mode power supplies
INSTAPOWER
connectPower single-phase
CP SNT 48 W 48 V 1 A
D
W
A
L
AC/DC
N
H
PWM
L
+
FUSE
+
−
N
DC
–
Technical data
Derating curve
Input
Input voltage
Input current
Input frequency
Turn-on current limit
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
85...264 V AC / 110...370 V DC
500 mA at rated load @ 230 V AC
50/ 60 Hz
Yes
Fusible link 2.5 A (T) / 250 V
Current (A)
46...55 V DC (adjustable via potentiometer)
1A
48 W
120 mVSS
105 %...150 % Iconst of max. output load; automatic reset
1.5
1
0.5
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
Varistor
11 ms @ 115 V AC / 50 ms @ 230 V AC
1%
10000 µF
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Max. capacitance at output
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
Electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Standards
Approvals
EMC standards
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
2
0.5 kV
1.5 kV
3 kV
4 kV
-10...+70 °C (Derating ab 55 °C)
-20 °C...+85 °C
80%
DIN EN 50178 (PELV), DIN EN 60950 (SELV)
cCSAus; cURus; GOSTME25; UL
EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4
mm²
Input/Output
2.5 / 0.5 / 4
90.5 / 70 / 62.5 mm
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Ordering data
Screw connection
Type
CP SNT 48W 48V 1A
Qty.
1
Order No.
8879230000
Note
Accessories
Note
A.44
1366860000 – 2013
connectPower single-phase
Switch-mode power supplies
WAVEPOWER
CP SNT 12 W 24 V 0.5 A
D
H
L
AC/DC
N
PWM
A
W
+
DC
–
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
Electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Power factor correction
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
85...265 V AC, 120...300 V DC
260 mA @ 115 V AC; 180 mA @ 230 V AC
50/ 60 Hz
2 A time-lag fuse (internal)
Varistor
24 V DC
0.5 A
12 W
0.1 %
Surge current / thermal cut-out
Varistor
30 ms @ 115 V AC / 80 ms @ 230 V AC
0.6%
No
0.5 kV
1.5 kV
3 kV
4 kV
-20...+50 °C
-40 °C...+85 °C
80%
Green LED
DIN EN 50178, DIN EN 60950, IEC950
IEC 61000-6 /-2, -3
No
CE; CSA; GOSTME25
mm²
Input/Output
2.5 / 0.5 / 2.5
92.4 / 22.5 / 112.4 mm
Ordering data
Screw connection
Type
CP SNT 12W 24V 0.5A
Qty.
1
Order No.
9918840024
Note
Accessories
Note
1366860000 – 2013
Supply voltage 24V and 0V can be cross-connected with ZQV 2.5N/2
A.45
Switch-mode power supplies
connectPower
connectPower single-phase
CP SNT 55 W 48 V 1.04 A
CP SNT 55 W 24-28 V 2.3 A
H
D
A
W
L
AC/DC
N
PWM
+
L
DC
–
+
+
FUSE
L
+
+
FUSE
N
N
+
+
85...265 V AC, 120...300 V DC
1.1 A @ 115 V AC; 0.55 A @ 230 V AC
50/ 60 Hz
2 A time-lag fuse (internal)
Varistor
85...265 V AC, 120...300 V DC
1.1 A @ 115 V AC; 0.55 A @ 230 V AC
50/ 60 Hz
2 A time-lag fuse (internal)
Varistor
48 V DC
1.04 A
50 W
< 50 mVeff
Surge current / thermal cut-out
Varistor
30 ms @ 115 V AC / 180 ms @ 230 V AC
1%
No
24...28 V DC
2.3 A
55 W
< 50 mVeff
Surge current / thermal cut-out
Varistor
30 ms @ 115 V AC / 180 ms @ 230 V AC
1%
No
0.5 kV
1.5 kV
3 kV
3 kV
0.5 kV
1.5 kV
3 kV
3 kV
-20...+40 °C
-40 °C...+85 °C
78%
Green LED
DIN EN 50178, DIN EN 60950, IEC950
IEC 61000-6 /-2, -3
No
CE; CSA; GOSTME25
-20...+40 °C
-40 °C...+85 °C
78%
Green LED
DIN EN 50178, DIN EN 60950, IEC950
IEC 61000-6 /-2, -3
No
CE; CSA; CSAEX; GOSTME25
Input/Output
4 / 0.1 / 4
98 / 57 / 131 mm
Input/Output
4 / 0.1 / 4
98 / 57 / 131 mm
Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Type
CP SNT 55W 48V 1.04A
Type
CP SNT 55W 24-28V 2.3A
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
Electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Power factor correction
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
mm²
Ordering data
Screw connection
Qty.
1
Order No.
9927480048
Qty.
1
Order No.
9927480024
Note
Accessories
Note
A.46
Bracket for wall mounting: 7920560000
Bracket for wall mounting: 7920560000
1366860000 – 2013
connectPower single-phase
CP SNT 55 W 12-15 V 3 A
Switch-mode power supplies
connectPower
CP SNT 55 W 5 V 3 A
H
D
A
W
L
AC/DC
N
PWM
+
L
DC
–
+
+
FUSE
L
+
+
FUSE
N
N
+
+
85...265 V AC, 120...300 V DC
1.1 A @ 115 V AC; 0.55 A @ 230 V AC
50/ 60 Hz
2 A time-lag fuse (internal)
Varistor
85...265 V AC, 120...300 V DC
1.1 A @ 115 V AC; 0.55 A @ 230 V AC
50/ 60 Hz
2 A time-lag fuse (internal)
Varistor
12...15 V DC
3A
36 W
< 50 mVeff
Surge current / thermal cut-out
Varistor
30 ms @ 115 V AC / 180 ms @ 230 V AC
1%
No
5 V DC
3A
15 W
< 50 mVeff
Surge current / thermal cut-out
Varistor
30 ms @ 115 V AC / 180 ms @ 230 V AC
1%
No
0.5 kV
1.5 kV
3 kV
3 kV
0.5 kV
1.5 kV
3 kV
3 kV
-20...+40 °C
-40 °C...+85 °C
78%
Green LED
DIN EN 50178, DIN EN 60950, IEC950
IEC 61000-6 /-2, -3
No
CE; CSA; GOSTME25
-20...+40 °C
-40 °C...+85 °C
78%
Green LED
DIN EN 50178, DIN EN 60950, IEC950
IEC 61000-6 /-2, -3
No
CE; CSA; GOSTME25
Input/Output
4 / 0.1 / 4
98 / 57 / 131 mm
Input/Output
4 / 0.1 / 4
98 / 57 / 131 mm
Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Type
CP SNT 55W 12-15V 3A
Type
CP SNT 55W 5V 3A
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
Electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Power factor correction
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
mm²
Ordering data
Screw connection
Qty.
1
Order No.
9927480012
Qty.
1
Order No.
9927480005
Note
Accessories
Note
1366860000 – 2013
Bracket for wall mounting: 7920560000
Bracket for wall mounting: 7920560000
A.47
Switch-mode power supplies
connectPower
connectPower single-phase
CP SNT 160 W 48 V 3.5 A
CP SNT 160 W 24-28 V 6.5 A
H
D
A
W
L
AC/DC
N
PWM
+
DC
–
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
Electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Power factor correction
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
mm²
min. 85/138 V AC, max. 195/250 V AC, typ. 115...230 V AC
2.9 A @ 115 V AC; 1.45 A @ 230 V AC
50/ 60 Hz
6.3 A time-lag fuse (internal)
Varistor
min. 85/138 V AC, max. 195/250 V AC, typ. 115...230 V AC
2.9 A @ 115 V AC; 1.45 A @ 230 V AC
50/ 60 Hz
6.3 A time-lag fuse (internal)
Varistor
48 V DC
3.5 A
168 W
0.2 %eff
Overload current and surge protection
Varistor
40 ms @ 115 V AC / 50 ms @ 230 V AC
1%
No
24...28 V DC
6.5 A
156 W
0.2 %eff
Overload current and surge protection
Varistor
40 ms @ 115 V AC / 50 ms @ 230 V AC
1%
No
0.5 kV
1.5 kV
3 kV
3 kV
0.5 kV
1.5 kV
3 kV
3 kV
0...+50 °C
-40 °C...+85 °C
85%
Green LED
DIN EN 50178, DIN EN 60950, IEC950
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
No
CE; cULus; GOSTME25
0...+50 °C
-40 °C...+85 °C
85%
Green LED
DIN EN 50178, DIN EN 60950, IEC950
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
No
CE; CSA; GOSTME25
Input/Output
4 / 0.1 / 4
127 / 57 / 175 mm
Input/Output
4 / 0.1 / 4
127 / 57 / 175 mm
Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Type
CP SNT 160W 48V 3.5A
Type
CP SNT 160W 24-28V 6.5A
Ordering data
Screw connection
Qty.
1
Order No.
9925340048
Qty.
1
Order No.
9925340024
Note
Accessories
Note
A.48
Bracket for wall mounting: 7920560000
Bracket for wall mounting: 7920560000
1366860000 – 2013
connectPower single-phase
CP SNT 160 W 12-15 V 8 A
Switch-mode power supplies
connectPower
CP SNT 160 W 5 V 8 A
H
D
A
W
L
AC/DC
N
PWM
+
DC
–
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
Electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Power factor correction
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
mm²
min. 85/138 V AC, max. 195/250 V AC, typ. 115...230 V AC
2.9 A @ 115 V AC; 1.45 A @ 230 V AC
50/ 60 Hz
6.3 A time-lag fuse (internal)
Varistor
min. 85/138 V AC, max. 195/250 V AC, typ. 115...230 V AC
2.9 A @ 115 V AC; 1.45 A @ 230 V AC
50/ 60 Hz
6.3 A time-lag fuse (internal)
Varistor
12...15 V DC
8A
96 W
0.2 %eff
Overload current and surge protection
Varistor
40 ms @ 115 V AC / 50 ms @ 230 V AC
1%
No
5 V DC
8A
40 W
0.2 %eff
Overload current and surge protection
Varistor
40 ms @ 115 V AC / 50 ms @ 230 V AC
1%
No
0.5 kV
1.5 kV
3 kV
3 kV
0.5 kV
1.5 kV
3 kV
3 kV
0...+50 °C
-40 °C...+85 °C
85%
Green LED
DIN EN 50178, DIN EN 60950, IEC950
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
No
CE; cULus; GOSTME25
0...+50 °C
-40 °C...+85 °C
85%
Green LED
DIN EN 50178, DIN EN 60950, IEC950
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
No
CE; cULus; GOSTME25
Input/Output
4 / 0.1 / 4
127 / 57 / 175 mm
Input/Output
4 / 0.1 / 4
127 / 57 / 175 mm
Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Type
CP SNT 160W 12-15V 8A
Type
CP SNT 160W 5V 8A
Ordering data
Screw connection
Qty.
1
Order No.
9925340012
Qty.
1
Order No.
9925340005
Note
Accessories
Note
1366860000 – 2013
Bracket for wall mounting: 7920560000
Bracket for wall mounting: 7920560000
A.49
Switch-mode power supplies
connectPower
connectPower single-phase
CP SNT 300 W 24 V 12.5 A
H
D
A
W
L
AC/DC
N
PWM
+
DC
–
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Signalling delay
Monitoring function
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
Electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Power factor correction
Derating
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
86...265 V AC, 100...200 V DC; typ 115...230 V AC
3.3 A @ 115 V AC; 1.65 A @ 230 V AC
50/ 60 Hz
Thermistor
Varistor
22...28 V DC adjustable
12.5 A
300 W
at 100 kHz: 2 mVSS, At 120 Hz: 20 mV AC eff
Overload current and surge protection
Varistor
40 ms @ 115 V AC / 40 ms @ 230 V AC
0.2%
Yes, max. 5 devices, active current splitting
2s
Output voltage, current, temperature
0.5 kV
1.5 kV
3 kV
4 kV
-15...+50 °C
-40 °C...+85 °C
80%
Current limiting: LED yellow / Error: LED red/ On: LED green
DIN EN 50178, DIN EN 60950, IEC950
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
PFC passive
Derating: 20% @ 60°C
CE; CSA; GOSTME25
mm²
Input/Output
4 / 0.1 / 4
155 / 240 / 101 mm
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Ordering data
Screw connection
Type
CP SNT 300W 24V 12.5A
Qty.
1
Order No.
9916250024
Note
Accessories
Note
A.50
Bracket for wall mounting: 7920560000
1366860000 – 2013
connectPower 3-phase
Switch-mode power supplies
connectPower
CP SNT 380-480 V AC / 24 V
H
D
A
W
L1
AC L2
L3
PWM
+
DC
–
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Overload protection
Insulation coordination (EN 50178)
Electrical isolation, output-earth
Electrical isolation, input-earth
Electrical isolation, input-output
Electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Power factor correction
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
306... 550 V AC, typ.: 360...480 V AC
120 mA @ 360 V AC; 100 mA @ 230 V AC
50/ 60 Hz
3 x 1 A time-lag fuse (internal)
Varistor
24 V DC
2.3 A
55 W
< 50 mVeff
Surge current / thermal cut-out
Varistor
120 ms @ 360 V AC / 120 ms @ 480 V AC
1%
No
Surge current / thermal cut-out
0.5 kV
1.5 kV
3 kV
3 kV
0...+50 °C
-40 °C...+85 °C
85%
Green LED
DIN EN 50178, DIN EN 60950, IEC950
EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3
No
CE; GOSTME25
mm²
Input/Output
4 / 0.1 / 4
108 / 60 / 168 mm
Derating loss: 10% @ 85 ? The internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Ordering data
Screw connection
Type
CP-SNT 380-480VAC/24V
Qty.
1
Order No.
9917790324
Note
Accessories
Note
1366860000 – 2013
Bracket for wall mounting: 7920560000
A.51
Switch-mode power supplies
DC/DC converter
connectPower
CP DCDC 50 W 22-24 V DC 2 A
CP DCDC 50 W 15 V DC 3 A
H
D
A
W
'&
²
Chopper
Transformer
Rectifier and
filtering
Chopper
Transformer
Rectifier and
filtering
'&
Technical data
Input
Input voltage
Input fuse
Output
Output voltage, min. / max.
Output current
Overload protection
General data
Ambient temperature (operational)
Storage temperature
Status indication
Switching frequency
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
mm²
18...30 V DC, typ. 24 V DC
internal
18...30 V DC, typ. 24 V DC
internal
22...24 V DC
2A
Surge current cut-out with self-reset
15 V DC
3A
Surge current cut-out with self-reset
-10...+60 °C (Derating ab 50 °C)
-40 °C...+85 °C
Green LED
200 kHz
CE; CSA; CSAEX; cULus; GOSTME25
-10...+60 °C (Derating ab 50 °C)
-40 °C...+85 °C
Green LED
200 kHz
CE; CSA; CSAEX; cULus; GOSTME25
Input/Output
4 / 0.1 / 4
98 / 57 / 131 mm
Input/Output
4 / 0.1 / 4
98 / 57 / 131 mm
Ordering data
Screw connection
Type
CP DCDC 50W 22-24V 2A
Qty.
1
Order No.
9919372424
Type
CP DCDC 50W 15V 3A
Qty.
1
Order No.
9919372415
Note
Accessories
Note
A.52
Bracket for wall mounting: 7920560000
Bracket for wall mounting: 7920560000
1366860000 – 2013
CP DCDC 50 W 12 V DC 3 A
CP DCDC 50 W 20-24 V DC 2 A
Switch-mode power supplies
DC/DC converter
CP DCDC 50 W 15 V DC 3 A
A
Chopper
Transformer
Rectifier and
filtering
Chopper
Transformer
Rectifier and
filtering
Chopper
Transformer
10…14 V DC, type 12V DC
internal
10…14 V DC, type 12V DC
internal
10…14 V DC, type 12V DC
internal
10.5...14.5 V DC
3A
Surge current cut-out with self-reset
20.5...29.5 V DC
2A
Surge current cut-out with self-reset
13...18 V DC
3A
Surge current cut-out with self-reset
-10...+60 °C (Derating ab 50 °C)
-40 °C...+85 °C
Green LED
200 kHz
CE; CSA; CSAEX; cULus; GOSTME25
-10...+60 °C (Derating ab 50 °C)
-40 °C...+85 °C
Green LED
200 kHz
CE; CSA; CSAEX; cULus; GOSTME25
-10...+60 °C (Derating ab 50 °C)
-40 °C...+85 °C
Green LED
200 kHz
CE; CSA; CSAEX; cULus; GOSTME25
Input/Output
4 / 0.1 / 4
98 / 57 / 131 mm
Input/Output
4 / 0.1 / 4
98 / 57 / 131 mm
Input/Output
4 / 0.1 / 4
98 / 57 / 131 mm
Type
CP DCDC 50W 12V 3A
Bracket for wall mounting: 7920560000
1366860000 – 2013
Qty.
1
Order No.
9919371212
Type
CP DCDC 50W 22-24V 2A
Bracket for wall mounting: 7920560000
Qty.
1
Order No.
9919371224
Type
CP DCDC 50W 15V 3A
Rectifier and
filtering
Qty.
1
Order No.
9919371215
Bracket for wall mounting: 7920560000
A.53
Switch-mode power supplies
DC/DC converter
connectPower
CP DCDC 50 W 12 V DC 3 A
CP DCDC 50 W 5 V DC 8 A
H
D
A
W
'&
²
Chopper
Transformer
Rectifier and
filtering
Chopper
Transformer
Rectifier and
filtering
'&
Technical data
Input
Input voltage
Input fuse
Output
Output voltage, max.
Output current
Overload protection
General data
Ambient temperature (operational)
Storage temperature
Status indication
Switching frequency
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
mm²
18...30 V DC, typ. 24 V DC
internal
18...30 V DC, typ. 24 V DC
internal
10.5...14.5 V DC
3A
Surge current cut-out with self-reset
5 V DC
8A
Surge current cut-out with self-reset
-10...+60 °C (Derating ab 50 °C)
-40 °C...+85 °C
Green LED
200 kHz
CE; CSA; CSAEX; cULus; GOSTME25
-10...+60 °C (Derating ab 50 °C)
-40 °C...+85 °C
Green LED
200 kHz
CE; CSA; CSAEX; cULus; GOSTME25
Input/Output
4 / 0.1 / 4
98 / 57 / 131 mm
Input/Output
4 / 0.1 / 4
98 / 57 / 131 mm
Ordering data
Screw connection
Type
CP DCDC 50W 12V 3A
Qty.
1
Order No.
9919372412
Type
CP DCDC 50W 5V 8A
Qty.
1
Order No.
9919372405
Note
Accessories
Note
A.54
Bracket for wall mounting: 7920560000
Bracket for wall mounting: 7920560000
1366860000 – 2013
A
1366860000 – 2013
A.55
Switch-mode power supplies
Switch-mode power supplies
connectPower DC/DC converter
ConnectPower DC/DC converter
DC voltage converter for preparation and potential isolation
in 24 V DC systems
•Overvoltage category III
•Class III protection
•Status of relay contact
•DC OK transistor output
A
%
{ \u
Technical data
Temperature derating
130
Pout [% Pn]
120
110
100
90
80
70
60
20
30
40
50
60
Ambient temperature [°C]
70
80
General technical specifications
Output characteristic curve / current limit
Earth discharge current
Ambient temp. Operating / storage temperature
Max. permitted humidity (operational)
Protection degree
Class of protection
Contamination degree
Insulation voltage
Overvoltage category
MTBF
Protection against load reverse voltages
Parallel capability (without diode module)
Mountable side-by-side without gaps
Housing version, metal
Signal operations
Mounting position, installation notice
Metal clip-on foot
EMC / shock / vibration
Noise emission according to EN55022
Interference immunity tests, according to
Limiting of mains voltage harmonic currents
Resistance against vibration and shock
Electrical safety (applied standards)
Electrical equipment of machines
Safety transformers for switched-mode power units
Machinery with electronic equipment
Safety extra-low voltage
Protective separation / protection against electrical shock
Protection against dangerous shock currents
Accessories
Diode module (for redundant power supply)
Capacity module (for pulse triggering of circuit breakers)
A.56
IU / > 120 % IN
< 0.005 mA
–25 °C … +70 °C / –40 °C … +85 °C
5 %…95 % RH
IP20
III
2
2.5 kV AC 1 min. / 1.5 kV AC 1 min. / 0.5 kV AC 1 min.
III
> 500,000 hrs. according to IEC 1709 (SN29500)
33…34 V DC
Yes, max. 5
Yes
Resistant to corrosion
LED green / red
Horizontal on TS35 DIN rail, above and below 50 mm
Clearance for air circulation, suitable for aligning without clearance gap
For installation in rotating systems
Yes
Class B
EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields),
EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN610004-6 (conducted),
EN61000-4-11 (Dips)
According to EN 61000-3-2
According to EN50178, shock: 5 g in all directions
According to EN60204
According to EN61558-2-17
According to EN50178 / VDE0160
SELV according to EN60950, PLEV according to EN60204
VDE0100-410 / according to DIN57100-410
According to VDE0106-101
Type
CP M DM 20
CP M CAP
Qty.
1
1
Order No.
1222210000
1222240000
1366860000 – 2013
Switch-mode power supplies
connectPower DC/DC converter
CP DCDC 250W 24V 10A
connectPower DC/DC converter
A
D
+
H
+
DC
–
–
DC OK
14
13
DC
W
Technical data
Input data
Rated input voltage
Input voltage range, DC
Current consumption, DC (typ.)
Current consumption, DC max.
Max. inrush current
Input fuse (internal)
Recommended back-up fuse
Output data
Nominal output voltage
Adjustment range of output voltage
Ramp-up time
Max. residual ripple
Nominal output current @ Unom
Short-circuit protection
Overload protection
Power boost @ 24 V DC, 60 °C, ED = 5 %
General information
Efficiency (typ.)
Max. power loss (no load)
Max. power loss (nominal load)
Mains failure bridging @ Inom
Length x width x height
Weight
Signal indication
LED green (DC OK)
LED red (fault)
DC OK transistor output "1" (max. load)
DC OK transistor output "0"
DC OK short circuit resistant
Floating contact
Contact load (NO contact)
Relay on/off
Connection data
Screw connection
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Tightening torque
Reverse polarity protection
Approvals
Approvals
Ordering data
1366860000 – 2013
24 V DC
18…31.2 V DC
11 A
15.5 A
< 10 A
Yes
16 A / DI/II Fusible link
16 A, Char. B Circuit breaker
16 A, Char. C Circuit breaker
24 V DC ± 1%,
22.5…29.5 V DC
≤ 100 ms
< 50 mVss
10 A @ 24 V DC
Yes
Yes
12 A for 1 min, ED = 5 %
mm
91%
<2W
< 24 W
> 7 ms @ 24 V DC
150 x 60 x 130
1.25 kg
Output voltage ≥ 21.6 V
Output voltage ≤ 20.4 V
Output voltage ≥ 21.6 V ( max. 250 mA)
Output voltage ≤ 20.4 V
Yes
Yes
max. 30V DC/0.5 A
Output voltage > 21.6 V / < 20.4 V
Input
Output
Screw connection
Screw connection
2 für (+-)
7 für (DCOK,13,14,++ ––) 0.5 / 6 mm²
0.5 / 6 mm²
0.5 / 2.5 mm²
0.5 / 2.5 mm²
26 / 12
26 / 12
0.5 … 0.6 Nm
Yes
CE, cURus, TÜV(IEC 60950-1), cULus, GL
Type
CP DCDC 250W 24V 10A
Qty.
1
Order No.
1313320010
A.57
A
A.58
1366860000 – 2013
Switch-mode power supplies
Uninterruptible power supplies (UPS)
Contents
Uninterruptible power supplies (UPS)
Uninterruptible power supplies (UPS)
1366860000 – 2013
Overview
B.2
UPS control unit
B.4
Battery modules
B.6
Buffer modules
B.8
B
B.1
Uninterruptible power supplies (UPS)
Uninterruptible power supplies (UPS) – Overview
Uninterruptible power supplies
Weidmüller‘s uninterruptible power supplies reliably protect
24 V DC consumers from voltage drop-outs and dips, such
as those that could occur as a result of mains faults. These
products therefore play a key role in increasing systems
availability.
B
The buffer module is the perfect solution for bridging
short-term power supply failures or dips of up to 100 ms.
The capacitor-based technology enables maintenance-free
operation, depending on the application, of up to 10 years.
The UPS control unit, together with the accompanying
battery module and the power supply, form a complete
DC UPS system with support times in minutes or hours.
The modular construction allows for the overall load to be
distributed into non-safe and safe load circuits, such that
often a smaller UPS can be designed.
A huge variety of operating types are available to suit the
particular application precisely. A remote input to block
battery operation, as well as multiple signal outputs, enable
remote operation of the UPS.
UPS with battery module
0DLQV
5HPRWHGLVFRQQHFWLRQ
,QWHUORFN
3520
$&
'&
9'&
²
5HOD\DQG
WUDQVLVWRURXWSXWV
&3'&8369
836FRQWUROXQLW
9'&
²
6DIH
ORDG
%DWWHU\PRGXOH
&3$%DWWHU\9'&
1RQVDIH
ORDG
UPS with buffer module
Relay and
transistor ouput
Mains
PRO-M
AC
DC
+24 V DC
+
–
CP DC BUFFER 24V 20A
+
Buffer module +24 V DC Safe
load
–
Non-safe
load
B.2
1366860000 – 2013
Uninterruptible power supplies (UPS)
Uninterruptible power supplies (UPS) – Overview
Can your facility afford to experience a power failure? Allow us
to connect you so that you are safe from failure and downtime.
Let’s connect.
B
It is critical to safeguard a facility‘s power supply in the event
of an outage. You cannot do without the important signals
from the field, which serve to control the entire process.
In addition, you also need to monitor a whole range of
functions and performance parameters for your facility.
Our highly modular power supply concept will support you
in the practical fulfilment of all your requirements. At the
same time, we will also familiarise ourselves with your future
requirements and provide you with an individual, tailor-made
solution, with components that are precisely aligned to work
with one another.
For a continual, lasting power supply and clean control
voltage, we use redundant circuits, selective short-circuit
solutions, battery reservoirs and DC/DC converters.
And because lightning and power surges can put an
uninterrupted power supply in a production facility at
risk, we also provide lightning and overvoltage protection.
The VPU series provides unrestricted operation of power
supplies and automation devices such as sensors, actuators
and control units. The subsequent availability of the power
supply means that all devices will restart in a controlled
manner. Let’s connect.
1366860000 – 2013
PRO-M
•Used to save space in automation technology
• Individual modulation of the output power
• Up to 5 devices can be switched directly, in parallel
• Optional diode modules with fault signalling
• Expanded temperature range –25 °C to 70 °C
UPS control unit
• Different status relays for status monitoring
•Direct switchover to battery operation in the event of
malfunction
• Automatic reconnection to load when power recovers
•Long battery life due to integrated deep discharge protection
• Optimised charging feature
B.3
Uninterruptible power supplies (UPS)
UPS control unit
•Two 24 V models in 10 A/20 A and 40 A
•Temperature-compensated charging feature for long
battery life
•Integrated battery diagnostics including continuous
availability test
•Status relay and additional transistor outputs for remote
monitoring
•Convenient LED displays for easy error analysis
{ \u
%
B
Technical data
Indication
Status relay ( max.load 30 V AC/DC 0.1 A)
Transistor outputs (24 to 27 V DC max. load 150 mA)
LED status indicator
General technical data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity
Protection degree
Class of protection
Pollution severity level
Overvoltage category
Insulation voltage input/output to housing/ground
MTBF
Protection against reverse voltages from the load
Parallel connection option
Housing version
Mounting position, installation notice
Overload protection
Short-circuit protection
EMC / shock / vibration
Interference emission
Interference immunity tests
Resistance against vibration and shock
Electrical safety (applied standards)
Electrical equipment of machines
Safety transformers for switch-mode power supplies
Machinery with electronic equipment
Extra-low voltage protection
Block diagram
Interlock – 1
Interlock + 2
Temperature 6
Sensor 7
–25 °C…+70 °C
–40 °C…+85 °C
5…95 %
IP 20
3
2
III
1300 V DC 1 min (typetest)
> 500,000 hours acc. to IEC 1709
32…34 V DC
Yes, only with diode module for redundancy
Metal, corrosion resistant
Horizontal on mounting rail TS35, 50 mm above and below
Space for free movement of air
Yes
Yes
Acc. to EN55022 Class B
Acc.to EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (fields),
EN61000-4-4 (burst), EN61000-4-5 (surge), EN610004-6 (conducted),
EN61000-4-11 (dips)
Acc.to IEC60954 Vibration: 2.3 g,
Acc.to IEC60068-2-31 shock: 30 g in all directions
Acc. to EN60204
Acc. to EN61558-2-17
Acc. to EN50178 / VDE0160
SELV acc. to EN60950, PLEV acc. to EN60204
Cabling
3 Alarm
Battery Capacity
Normal / Buffering
Alarm
Cut-off / Bat.Failure
Selector switches
– Buffer time
– Battery size
– DIP switch
– 10/20A
(only1370050010)
4 Buffering
5 Charging
11
14 Alarm
12
21
24 Buffering
22
31
34 Charging
32
+
µC
+
24V DC
Input
Charger
–
24V DC
Output
–
Bat
–
B.4
Fault (alarm), battery operation (buff.), charging (charg.)
Fault (alarm), battery operation (buff.), charging (charg.)
Three-colour LED: battery capacities
> 85 % green, > 40 % yellow, > 20 % red, < 20 % red (flashing)
Green/yellow LED: normal / buffering
Yellow/red LED: temperature alarm / alarm
Yellow/red LED: switch-off / battery fault
+ +
Unbuffered
DC Load
– +
– + – +
24V DC Output
Buffered
DC Load
– +
– + – + – +
Input Battery Output
–
+
Power Supply
DC UPS
Battery Module
PRO–M Series
CP DC UPS 24V DC 20A/10A
CP DC UPS 24V DC 40A
CP A BATTERY 24V DC .. Ah
1 2 3 4 5 11 21 31
6 7 12 14 22 24 32 34
7
6
Temperature Sensor
1366860000 – 2013
CP DC UPS 24V 20A/10A
UPS control unit
Uninterruptible power supplies (UPS)
UPS control unit
CP DC UPS 24V 40A
'
+
:
B
Technical data
Input
Rated input voltage
Input voltage range
Rated input voltage (up to 60 °C)
Input current, max. (to 45 °C)
Input fuse
Standby current (without battery)
Standby current (with fully charged battery)
Reverse polarity protection
Output
Rated output voltage
Output voltage, normal operation (Imax)
Output voltage, battery operation (Imax)
Rated output current (up to 60 °C)
Continuous output current (up to 70 °C), derating from 60 °C
Continuous output current (up to 45 °C)
Power Boost@24 V DC, 60 °C
Integrated battery charger
Charging feature
Charging voltage (temperature compensated)
Temperature coefficient
Charging current
Battery availability test
Battery module
Rated voltage
Storage medium (AGM battery)
Parallel connection option
Operating elements and control inputs
Output current selector switch
Battery in Ah selector switch
Buffer times in minutes selector switch
DIP switch
Remote disconnection (Interlock)
Temperature sensor connection
General data
Buffer times
Efficiency
Power loss
Height x width x depth
Weight
Approvals
Connection data
Conductor connection system
Wire cross-section, rigid mm² (min./max.)
Wire cross-section, flexible mm² (min./max.)
Wire cross-section, AWG/kcmil (min./max.)
Stripping length (mm)
Tightening torque range (NM)
Ordering data
1366860000 – 2013
24 V DC
20…30 V DC
≤ 13 A (for 10 A) │≤ 23 A (for 20 A)
≤ 15 A (for 10 A)│≤ 27 A (for 20 A)
Yes, 30 A
max. 200 mA
max. 0,5 A
Yes
24 V DC
20…30 V DC
≤ 43 A
≤ 51 A
Yes, 60 A
max. 200 mA
max. 0,5 A
Yes
24 V DC
Vo = Vin – 0,2 V
Vo = Vin – 0,3 V
10 A / 20 A
7,5 A / 15 A
12 A / 24 A
12 A / 24 A for 1 min, ED = 5 %
24 V DC
Vo = Vin – 0,2 V
Vo = Vin – 0,3 V
40 A
24 A
48 A
48 A for 1 min, ED = 5 %
IU characteristic curve
27, 48 V @ 20 °C
– 48 mV / °C
0,15 CA
Yes, each minute
IU characteristic curve
27, 48 V @ 20 °C
– 48 mV / °C
0,15 CA
Yes, each minute
24 V DC
1,3 Ah, 3,4 Ah, 7,2 Ah, 12 Ah, 17 Ah (selectable, with rotary switch)
Yes, max. 2
24 V DC
3,4 Ah, 7,2 Ah, 12 Ah, 17 Ah (selectable, with rotary switch)
Yes, max. 2
10A / 20A
1,3 / 3,4 / 7,2 / 12 / 17 / No Battery / Service
0,5 / 1 / 3 / 5 / 10 / 20 / 30 / 45 / ∞ / ∞ w/0
Inversion of the transistor outputs; operation without temperature sensor
Yes
Yes, for NTC 10 KΩ
No
3,4 / 7,2 / 12 / 17 / No Battery / Service
0,5 / 1 / 3 / 5 / 10 / 20 / 30 / 45 / ∞ / ∞ w/0
Inversion of the transistor outputs; operation without temperature sensor
Yes
Yes, for NTC 10 KΩ
Depending on the connected battery (adjustable)
≥ 98 % Normal operation, battery charged
≥ 96 % Normal operation, battery charging
≥ 98 % Battery operation
<10 W
130 / 66 / 150 mm
0,98 kg
Depending on the connected battery (adjustable)
≥ 98 % Normal operation, battery charged
≥ 96 % Normal operation, battery charging
≥ 98 % Battery operation
<10 W
130 / 66 / 150 mm
1,0 kg
CE, TÜV; Pending: cURus, cULus, GL
Input/output/battery
Signal
Screw connection
0,5/16
0,5/6
0,5/16
0,5/4
26/6
26/12
10
8
1,2 … 1,5
0,5…0,6
CE, TÜV; Pending: cURus, cULus, GL
Input/output/battery
Signal
Screw connection
0,5/16
0,5/6
0,5/16
0,5/4
26/6
26/12
10
8
1,2 … 1,5
0,5…0,6
Type
CP DC UPS 24 V 20 A/10 A
Qty.
1
Order No.
1370050010
Type
CP DC UPS 24 V 40 A
Qty.
1
Order No.
1370040010
B.5
Uninterruptible power supplies (UPS)
Battery modules
•Maintenence-free lead-acid batteries from
3.4 Ah to 17 Ah
•Integrated temperature sensor for optimal
battery charging
•Integrated fuse for reliable activation
•Capacity up to 40 A / 30 min or 1 A / 30 hrs
•Robust metal housing for wall mounting
CP A BATTERY 24V DC 3,4 Ah
B
CP A BATTERY 24V DC 7,2 Ah
%
Technical data
%
Rated voltage
Nominal capacity
Max. charging current at 0.15 CA
Fuse (ATO flat blade fuse max. 80 V DC)
Buffer time
24 V DC
3,4 Ah
0,51 A
25 A
11,3 min @ 10 A
5 min @ 20 A
Max. output current
Parallel connection option
Series switching capability
Temperature sensor
General data
Battery type (maintenance-free battery)
Battery type Panasonic
Lifetime in years (application-dependent)
Ambient temperature
Storage temperature
Latest commissioning in months
Max. perm. air humidity
Class of protection
Protection degree
Vibration mounting rail assembly/wall mounting acc. to IEC 68-2-6
Shock mounting rail assembly/wall mounting acc. to IEC 68-2-27
Height x width x depth
Weight
Approvals
Connection data (input/output, signal)
Screw connection
Wire cross-section, rigid mm² (min./max.)
Wire cross-section, flexible mm² (min./max.)
Wire cross-section, AWG/kcmil (min./max.)
Tightening torque range (Nm)
25 A
Yes, max. 2
No
NTC 8 kΩ
24 V DC
7,2 Ah
1,8 A
2 x 25 A
26,5 min @ 10 A
11,5 min @ 20 A
5 min @ 30 A
50 A
Yes, max. 2
No
NTC 8 kΩ
Valve Regulated Lead Acid (VRLA)- Absorbed Glass Mat (AGM)
UP-RW1220P
6…9 @ 20 °C
0 °C...+40 °C
–15 °C…+40 °C
9
5…95 %
III
IP 20
0.7 g / 0.7 g
30 g
144 / 108 / 126 mm
3,6 kg
CE, TÜV
Input/output/battery
Signal
Pluggable
0,2/6
0,2/1,5
0,25/6
0,2/1,5
24/10
28/16
0,5…0,6
0,2…0,25
Valve Regulated Lead Acid (VRLA)- Absorbed Glass Mat (AGM)
LC-R127R2PG
6…9 @ 20 °C
0 °C...+40 °C
–15 °C…+40 °C
9
5…95 %
III
IP 20
– / 0.7 g
30 g
155 / 162 / 126 mm
5,9 kg
CE, TÜV
Input/output/battery
Signal
Pluggable
0,2/6
0,2/1,5
0,25/6
0,2/1,5
24/10
28/16
0,5…0,6
0,2…0,25
Type
CP A BATTERY 24V DC 3,4 Ah
Type
CP A BATTERY 24V DC 7,2 Ah
Ordering data
Qty.
1
Order No.
1251070000
Qty.
1
Order No.
1251080000
6HQVRU
'
+
17&
:
B.6
3(
1366860000 – 2013
CP A BATTERY 24V DC 12 Ah
Rated voltage
Nominal capacity
Max. charging current at 0.15 CA
Fuse (ATO flat blade fuse max. 80 V DC)
Buffer time
Max. output current
Parallel connection option
Series switching capability
Temperature sensor
General data
Battery type (maintenance-free battery)
Battery type Panasonic
Lifetime in years (application-dependent)
Ambient temperature
Storage temperature
Latest commissioning in months
Max. perm. air humidity
Class of protection
Protection degree
Vibration mounting rail assembly/wall mounting acc. to IEC 68-2-6
Shock mounting rail assembly/wall mounting acc. to IEC 68-2-27
Height x width x depth
Weight
Approvals
Connection data (input/output, signal)
Screw connection
Wire cross-section, rigid mm² (min./max.)
Wire cross-section, flexible mm² (min./max.)
Wire cross-section, AWG/kcmil (min./max.)
Tightening torque range (Nm)
Ordering data
%XIIHUWLPHVRXWSXWYROWDJHFXUYH
%XIIHUWLPHVQ>PLQ@
CP A BATTERY 24V DC 17 Ah
%
Technical data
Uninterruptible power supplies (UPS)
Battery modules
B
%
24 V DC
12 Ah
1,8 A
2 x 25 A
51 min @ 10 A
22,7 min @ 20 A
9,2 min @ 30 A
50 A
Yes, max. 2
No
NTC 8 kΩ
24 V DC
17 Ah
2,55 A
2 x 25 A
81 min @ 10 A
34,2 min @ 20 A
13,5 min @ 30 A
50 A
Yes, max. 2
No
NTC 8 kΩ
Valve Regulated Lead Acid (VRLA)- Absorbed Glass Mat (AGM)
LC-RA1212PG
6…9 @ 20 °C
0 °C...+40 °C
–15 °C…+40 °C
9
5…95 %
III
IP 20
– / 0.7 g
30 g
155 / 229 / 126 mm
9,2 kg
CE, TÜV
Input/output/battery
Signal
Pluggable
0,2/6
0,2/1,5
0,25/6
0,2/1,5
24/10
28/16
0,5…0,6
0,2…0,25
Valve Regulated Lead Acid (VRLA)- Absorbed Glass Mat (AGM)
LC-XD1217APG
10…12 @ 20 °C
0 °C...+40 °C
–15 °C…+40 °C
9
5…95 %
III
IP 20
– / 0.7 g
30 g
178 / 232 / 160 mm
13,4 kg
CE, TÜV
Input/output/battery
Signal
Pluggable
0,2/6
0,2/1,5
0,25/6
0,2/1,5
24/10
28/16
0,5…0,6
0,2…0,25
Type
CP A BATTERY 24V DC 12 Ah
Type
CP A BATTERY 24V DC 17 Ah
Qty.
1
Order No.
1251090000
Qty.
1
Order No.
1251110000
&3$%DWWHU\9'&$K
&3$%DWWHU\9'&$K
&3$%DWWHU\9'&$K
&3$%DWWHU\9'&$K
&3$%DWWHU\9'&$K
1366860000 – 2013
2XWSXWYROWDJH>$@
B.7
Uninterruptible power supplies (UPS)
Buffer modules
•Maintenance-free UPS on capacitor basis with a
capacity to support 20 A / 260 ms
•Parallel switching to increase the output current or
support time
•Status notification via LED and relay contact
CP DC Buffer 24V 20A
B
%
{\
Technical data
Input
Input voltage
Input current
Max. approved input current
Surge protection
Output
Output voltage
Output current
Parallel connection option
Overload protection
Surge protection
Status relay (max. load)
24 V DC (22,5…30 V DC)
0…22 A
Max. 22 A
35 V DC suppressor diode
24 V DC
20 A, max. 22 A
Yes, without diode module
≥ 22 A (Only at discharge)
31…34 V (Only at discharge)
Input voltage OK (30 V AC/DC 2 A)
Operational (24 V AC/DC 300 mA)
Display
Operational
General data
Efficiency
Insulation voltage input/output
Storage medium
Buffer times
MTBF
Ambient temperature
Storage temperature
Max. perm. air humidity
Height x width x depth
Standards applied
EMC
Weight
Approvals
Connection data
Conductor connection system
Wire cross-section mm² (nominal/min./max.)
LED green: ready
mm
Ordering data
95 %
1 kV
Internal condenser
260 ms bei 20 A, 6 s at 1 A
> 500,000 hours acc. to IEC 1709
–25 °C…+70 °C
–40 °C…+85 °C
5…95 %
130 / 66 / 150
EN50178, EN60950
EN55011, EN55022, EN55024, EN61000-6-2,-3,-4
1,15 kg
CE, TÜV, cURus, cULus
Input
Output
Signal
Screw connection
10/0,3/16
10/0,3/16
4/0,13/6
Type
CP DC Buffer 24V 20A
Qty.
1
Order No.
1251220000
Block diagram
D
Input
+
–
Output
+
–
H
Ready
–
Fail
W
B.8
1366860000 – 2013
Fuse protection for 24 V DC circuits
Contents
Fuse protection for 24 V DC circuits
Fuse protection for 24 V DC circuits
Overview
C.2
WAVEGUARD
C.4
C
1366860000 – 2013
C.1
Fuse protection for 24 V DC circuits
Fuse protection for 24 V DC circuits – Overview
Fuse protection
A 24-V DC control voltage has become the standard in the
automation industry. Selective fuse protection is often used
when the power is being supplied by PLC-guided controllers.
It divides the total load into separate, logically connected
safety circuits. For example, the CPU, actuators and sensors
can be separated in the load circuits. This selective load
protection helps to decrease facility downtime and also to
simplify troubleshooting. When a disruption (short circuit)
occurs on a standard protective system, the entire power
supply is interrupted. In a system using selective fuse
protection, only the fuse in the one disrupted load circuit is
triggered. If the fuse is triggered quick enough so that other
loads (and particularly the CPU) can continue functioning
properly, then various control algorithms can be used to
deal with the disruption. It is then possible to shut down the
facility in an orderly and controlled fashion.
C
A fundamental problem when using ordinary fuses is
that they take a relatively long time to trigger. Usually, a
C.2
switched-mode power supply is already well over the surgecurrent limit (typically 120 % of Inom) before its fuse triggers.
Ordinary fuses are therefore not suitable for constructing a
selective fuse protective system. Such systems present DC
fuses with special challenges. They must be able to switch
off quickly enough but they must also be able to tolerate the
start-up surge currents from consumer loads. Weidmüller‘s
electronic fuses, from our established WAVEGUARD line,
are the answer to both of these challenges: they are quick
acting but can also tolerate start-up currents. You can easily
implement selective load protection using our WAVEGUARD
models.
In addition, Weidmüller‘s electronic fuses feature a floating
alarm contact and a reset input. This allows a PLC controller
to query the status of the fuse or to perform an automated
reset after troubleshooting. This provides you with a
convenient method for remotely maintaining a complex
facility. As a result, you save both time and money.
1366860000 – 2013
Fuse protection for 24 V DC circuits
Fuse protection for 24 V DC circuits – Overview
Resetting
The WAVEGUARD family can be reset manually or by using
an external signal. They can be reset remotely by simply
applying a 24 V signal pulse on the reset input. The reset
occurs on the falling edge of the signal.
Note: A cyclical automatic reset is not permitted and can
lead to a malfunction.
Block diagram WAVEGUARD
INPUT
24 V
Reset
(8)
(1)
(9)
gn
24 V
fail
re
(2)
0V
OUTPUT
(7)
(3)
C
NC contact
50 Vuc/0.05A
Signalling
A red LED displays when the electronic fuse has been
triggered. An alert is also sent out over a floating alarm
contact. A green LED signals that the unit is switched on.
The alarm contact uses an NC contact.
WaveGuard
1366860000 – 2013
C.3
Fuse protection for 24 V DC circuits
WAVEGUARD
24 V DC 1.6 A
24 V DC 3.15 A
D
H
INPUT
24 V
Reset
C
0V
W
(8)
(1 )
(9 )
gn
rt
OUTPUT
24 V
fail
(7 )
(2 )
(3 )
NC contact
50 V uc /0.05 A
Current
(A )
Current
(A )
20
18
16
14
12
10
8
6
4
2
0
24
22
20
18
16
14
12
10
8
6
4
2
0
Time ( m s )
0
20
40
60
80
10 0
12 0
14 0
T i m e ( m s)
0 10 15 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0
16 0
Technical data
Input
Rated control voltage
Rated current
Reset
Output
Status relay / CO contact
Signalling delay
General data
Ambient temperature
Storage temperature
Status indication
Standards
EMC standards
Sliding switch
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
mm²
24 V DC
1.6 A
Impulse > 100 ms +24 V, falling edge ON
24 V DC
3.15 A
Impulse > 100 ms +24 V, falling edge ON
NC contact, max. 50 V / 0.05 A; for low voltage only!
3.5 ms typ.
NC contact, max. 50 V / 0.05 A; for low voltage only!
3.5 ms typ.
0...+55 °C
-20 °C...+85 °C
LED green: OK, LED red: tripped
DIN EN 50178
EN 55011, EN 61000-6-1, 2, 4
OFF - wait 10 s - ON; on / off
cCSAus; CE; cURus; GOSTME25
0...+55 °C
-20 °C...+85 °C
LED green: OK, LED red: tripped
DIN EN 50178
EN 55011, EN 61000-6-1, 2, 4
OFF - wait 10 s - ON; on / off
cCSAus; CE; cURus; GOSTME25
2.5 / 0.5 / 2.5
1.5 / 0.5 / 2.5
92.4 / 22.5 / 72
92.4 / 22.5 / 72
Periodic
auto-reset not permitted; Tu=23 °C,Tension
single module
Screw connection
clamp connection
2.5 / 0.5 / 2.5
1.5 / 0.5 / 2.5
92.4 / 22.5 / 72
92.4 / 22.5 / 72
Periodic
auto-reset not permitted; Tu=23 °C,Tension
single module
Screw connection
clamp connection
Type
WGS 24Vdc 1,6A
WGZ 24Vdc 1,6A
Type
WGS 24Vdc 3,15A
WGZ 24Vdc 3,15A
Ordering data
Screw connection
Tension-clamp connection
Qty.
1
1
Order No.
8618890000
8621040000
Qty.
1
1
Order No.
8618910000
8621030000
Note
Accessories
Note
C.4
Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5N/2
Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5N/2
1366860000 – 2013
24 V DC 6.3 A
Fuse protection for 24 V DC circuits
WAVEGUARD
24 V DC 8 A
D
H
INPUT
24 V
Reset
0V
W
(8)
(1 )
(9 )
gn
rt
24 V
fail
(7 )
(2 )
(3 )
Current
(A )
Current
(A )
OUTPUT
NC contact
50 V uc /0.05 A
26
24
22
20
18
16
14
12
10
8
6
4
Time (ms)
0
10
15 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0
65
60
55
50
45
40
35
30
25
20
15
10
5
C
Time (ms)
0
5
10
15
20
25
30
35
40
45
50
Technical data
Input
Rated control voltage
Rated current
Reset
Output
Status relay / CO contact
Signalling delay
General data
Ambient temperature
Storage temperature
Status indication
Standards
EMC standards
Sliding switch
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
mm²
24 V DC
6.3 A
Impulse > 100 ms +24 V, falling edge ON
24 V DC
8A
Impulse > 100 ms +24 V, falling edge ON
NC contact, max. 50 V / 0.05 A; for low voltage only!
3.5 ms typ.
NC contact, max. 50 V / 0.05 A; for low voltage only!
3.5 ms typ.
0...+55 °C
-20 °C...+85 °C
LED green: OK, LED red: tripped
DIN EN 50178
EN 55011, EN 61000-6-1, 2, 4
OFF - wait 10 s - ON; on / off
cCSAus; CE; cURus; GOSTME25
0...+55 °C
-20 °C...+85 °C
LED green: OK, LED red: tripped
DIN EN 50178
EN 55011, EN 61000-6-1, 2, 4
OFF - wait 10 s - ON; on / off
cCSAus; CE; cURus; GOSTME25
2.5 / 0.5 / 2.5
1.5 / 0.5 / 2.5
92.4 / 22.5 / 72
92.4 / 22.5 / 72
Periodic
auto-reset not permitted; Tu=23 °C,Tension
single module
Screw connection
clamp connection
2.5 / 0.5 / 2.5
1.5 / 0.5 / 2.5
92.4 / 22.5 / 72
92.4 / 22.5 / 72
Periodic
auto-reset not permitted; Tu=23 °C,Tension
single module
Screw connection
clamp connection
Type
WGS 24Vdc 6,3A
WGZ 24Vdc 6,3A
Type
WGS 24Vdc 8,0A
WGZ 24VDC 8,0A
Ordering data
Screw connection
Tension-clamp connection
Qty.
1
1
Order No.
8618930000
8621020000
Qty.
1
1
Order No.
8618940000
8621010000
Note
Accessories
Note
1366860000 – 2013
Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5N/2
Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5N/2
C.5
Fuse protection for 24 V DC circuits
WAVEGUARD
24 V DC 0.5...5 A
D
H
INPUT
24 V
Reset
C
0V
W
(8)
(1 )
(9 )
gn
rt
OUTPUT
24 V
fail
(7 )
(2 )
(3 )
NC contact
50 V uc /0.05 A
Technical data
Derating curve
Dynamic tripping characteristic
Input
Rated control voltage
Rated current
Reset
Output
Status relay / CO contact
Signalling delay
General data
Ambient temperature
Storage temperature
Status indication
Standards
EMC standards
Sliding switch
Approvals
24 V DC
0.5...5 A adjustable
Impulse > 100 ms +24 V, falling edge ON
Tripping current: 0.5 A
Tripping current (A)
25
20
15
10
5
0
0
20
40
NC contact, max. 50 V / 0.05 A; for low voltage only!
3.5 ms typ.
0...+55 °C
-20 °C...+85 °C
LED green: OK, LED red: tripped
DIN EN 50178
EN 55011, EN 61000-6-1, 2, 4
OFF - wait 10 s - ON; on / off
cCSAus; CE; cURus; GOSTME25
mm²
80
100
120
140
60
80
100
120
140
Time (ms)
Tripping current: 5.0 A
Tripping current (A)
25
20
15
10
5
0
0
20
40
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
60
Time (ms)
2.5 / 0.5 / 2.5
1.5 / 0.5 / 2.5
92.4 / 22.5 / 72
92.4 / 22.5 / 72
Periodic
auto-reset not permitted; Tu=23 °C,Tension
single module
Screw connection
clamp connection
Ordering data
Screw connection
Tension-clamp connection
Type
WGS 24Vdc 0.5...5A
WGZ 24Vdc 0.5...5A
Qty.
1
1
Order No.
8710270000
8727630000
Note
Accessories
Note
C.6
Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5N/2
1366860000 – 2013
Unregulated power supplies
Contents
Unregulated power supplies
Unregulated power supplies
Overview
D.2
compactPower
D.4
D
1366860000 – 2013
D.1
Unregulated power supplies
Unregulated power supplies – Overview
Unregulated power supplies – compactPower
D
D.2
Compact power supply units are important links in the
power supplies for controllers. They are used where
processes or control voltages are required that vary from the
mains voltage. Transformers provide the electrical isolation
between the input circuit and the output circuit.
The minimum requirement (to VDE 0550) is 2,000 V.
Screw terminals secure the input-side connection to the
mains. The single-phase devices are rated for a nominal
voltage of ∼230 ± ∼15 V, or ∼400 V ± ∼15 V, 50/60 Hz,
the 3-phase devices for 3 x 400 V ± 5 %. The secondary
DC voltage from the transformer is conducted to a bridge
rectifier where it is rectified.
The pulsating DC voltage is then fed from the rectifier and
filtered to a low residual ripple by means of an electrolytic
capacitor.
This DC voltage is then fed to the output terminal. These
are designed as pluggable screw terminals. A varistor is
integrated in the output circuitry to attenuate voltage peaks.
The operating status is indicated by means of a green LED
via the output circuit. Devices with 600 W and higher are
equipped with a fan.
Single-phase unregulated power supplies
Three-phase unregulated power supplies
1366860000 – 2013
Unregulated power supplies
Unregulated power supplies – Overview
Well-balanced spectrum for optimum economy
Block diagram for single-phase devices CP NT
The output currents of these practical products are defined
by way of two ambient temperatures.
Size selection is based on the maximum effectiveness of the
components.
INPUT
+15 V
0V
–15 V
Adapted to standard voltages in accordance
with IEC 38
400 V
PE
By choosing the appropriate terminals, the ± 15 V tapping
capability allows the single-phase devices to be connected
to six different nominal AC voltages: 215, 230, 245, 385,
400, 415 V.
The ± 5 % tapping capability allows the 3-phase devices to
be connected to three different nominal voltages: 380, 400,
415 V.
Reliable short-circuit and overload protection
Integrated on the secondary side in device sizes up to
CP NT 192 W, the FKS fuse protects against overloads
and shortcircuits. For the devices CP NT 264 W and
CP NT 432 W, this protection is achieved by means of a
thermostatic switch built into the transformer.
230 V
.
.
.
.
.
D
Block diagram for 3-phase devices
CP NT3 250 / 400 / 500 W
INPUT
+5% 400 V –5% +5% 400 V –5% +5% 400 V –5%
3x
OUTPUT
+
+
24V DC
=
130°
PE
-
~
Block diagram for 3-phase devices
CP NT3 600 / 750 / 1.000 W
Easy mounting
Keyhole assembly simplifies mounting and saves time. A
snap-on fixing attachment for 35 mm DIN rails is available as
an accessory for single-phase devices up to 144 W.
Simply plugged into the device and secured with two
screws, it ensures easiest possible mounting!
OUTPUT
+
+
24V DC
INPUT
+5% 400 V –5% +5% 400 V –5% +5% 400 V –5%
3x
=
130°
M
PE
~
OUTPUT
+
+
24V DC
0V
Fail
Transformers, vacuum-impregnated, painted black
• No humming
• Moisture cannot ingress into the windings
• Windings mechanically secured
• Improved heat dissipation from the windings
• Good heat dissipation
Unregulated power supplies
single-phase
Unregulated power supplies
3-phase
1366860000 – 2013
D.3
Unregulated power supplies
compactPower
compactPower single-phase
CP NT 36
CP NT 72
INPUT
OUTPUT
+15V
0V
-15V
230V
400V
PE
D
.
.
.
.
INPUT
+
+
24VDC
+15V
0V
-15V
-
230V
400V
PE
.
OUTPUT
+
+
24VDC
.
.
.
.
.
Technical data
Input
Input voltage
Input current
Input frequency
No-load input current
Ext. Back-up fuse
Output
Output voltage
Output current at 40°C
Output current at 55°C
Output power
Max. residual ripple
Fusing
Protective circuit, load side
Insulation coordination (EN 50178)
Electric shock protection
Insulation strength
Insulation class
Protection degree
Class of protection
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Mounting position, installation notice
Installation advice
Status indication
Height x width x depth
Weight
Standards
EMC standards
Approvals
Dimensions
Clamping range (nominal / min. / max.)
mm²
230 V/ 400 V ±15 V
0.35 A/ 0.2 A
50/ 60 Hz
0.1 A / 0.06 A
0.63 A / 0.315 A time-lag
230 V/ 400 V ±15 V
0.56 A/ 0.32 A
50/ 60 Hz
0.13 A / 0.08 A
0.1 A / 0.63 A time-lag
24 V DC SELV
1.5 A
1A
36 W
<5%
3 A time-lag flat cable-lug fuse
Varistor
24 V DC SELV
3A
2.5 A
72 W
<5%
7.5 A time-lag flat cable-lug fuse
Varistor
acc. to BGV A3
4 kV
B
IP 20
I
acc. to BGV A3
4 kV
B
IP 20
I
-20...+55 °C
-20 °C...+80 °C
80%
Arbitrary, horizontally, on terminal rail TS 35
Direct mounting, TS 35 with clip-on plate
Green LED
123 / 78 / 68 mm
1.5 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
CE; cULus; GOSTME25
-20...+55 °C
-20 °C...+80 °C
83%
Arbitrary, horizontally, on terminal rail TS 35
Direct mounting, TS 35 with clip-on plate
Green LED
125 / 84 / 85 mm
2.1 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
CE; cULus; GOSTME25
Input
2.5 / 0.13 / 2.5
Input
2.5 / 0.13 / 2.5
Output
2.5 / 0.5 / 4
Output
2.5 / 0.5 / 4
Note
Ordering data
Screw connection
Type
CP NT 36W 24V 1.5A
Qty.
1
Order No.
8575260000
Type
CP NT 72W 24V 3A
Qty.
1
Order No.
8575270000
Note
Accessories
Note
D.4
Clip-in plate for TS35: 8588900000
Clip-in plate for TS35: 8588910000
1366860000 – 2013
compactPower single-phase
CP NT 144
CP NT 192
INPUT
OUTPUT
+15V
0V
-15V
230V
400V
PE
Unregulated power supplies
compactPower
.
.
.
.
INPUT
+
+
24VDC
+15V
0V
-15V
-
230V
400V
PE
.
OUTPUT
+
+
24VDC
.
.
.
.
.
D
Technical data
Input
Input voltage
Input current
Input frequency
No-load input current
Ext. Back-up fuse
Output
Output voltage
Output current at 40°C
Output current at 55°C
Output power
Max. residual ripple
Fusing
Protective circuit, load side
Insulation coordination (EN 50178)
Electric shock protection
Insulation strength
Insulation class
Protection degree
Class of protection
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Mounting position, installation notice
Installation advice
Status indication
Height x width x depth
Weight
Standards
EMC standards
Approvals
Dimensions
Clamping range (nominal / min. / max.)
mm²
230 V/ 400 V ±15 V
0.95 A/ 0.55 A
50/ 60 Hz
0.33 A / 0.19 A
1.6 A / 1.0 A time-lag
230 V/ 400 V ±15 V
1.3 A/ 0.7 A
50/ 60 Hz
0.3 A / 0.16 A
2.0 A / 1.25 A time-lag
24 V DC SELV
6A
5A
144 W
<5%
10 A time-lag flat cable-lug fuse
Varistor
24 V DC SELV
8A
7A
192 W
<5%
15 A time-lag flat cable-lug fuse
Varistor
acc. to BGV A3
4 kV
B
IP 20
I
acc. to BGV A3
4 kV
B
IP 20
I
-20...+55 °C
-20 °C...+80 °C
88%
Arbitrary, horizontally, on terminal rail TS 35
Direct mounting, TS 35 with clip-on plate
Green LED
135 / 96 / 92 mm
3.1 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
CE; cULus; GOSTME25
-20...+55 °C
-20 °C...+80 °C
90%
Input
2.5 / 0.13 / 2.5
Input
2.5 / 0.13 / 2.5
Direct mounting
Green LED
145 / 105 / 105 mm
4.3 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
CE; cULus; GOSTME25
Output
2.5 / 0.5 / 4
Output
2.5 / 0.5 / 4
Note
Ordering data
Screw connection
Type
CP NT 144W 24V 6A
Qty.
1
Order No.
8575280000
Type
CP NT 192W 24V 8A
Qty.
1
Order No.
8575300000
Note
Accessories
Note
1366860000 – 2013
Clip-in plate for TS35: 8588920000
D.5
Unregulated power supplies
compactPower
compactPower single-phase
CP NT 264
CP NT 432
INPUT
OUTPUT
+15V
0V
-15V
230V
400V
PE
D
.
.
.
.
INPUT
+
+
24VDC
+15V
0V
-15V
-
230V
400V
PE
.
OUTPUT
+
+
24VDC
.
.
.
.
.
Technical data
Input
Input voltage
Input current
Input frequency
No-load input current
Ext. Back-up fuse
Output
Output voltage
Output current at 40°C
Output current at 55°C
Output power
Max. residual ripple
Fusing
Protective circuit, load side
Insulation coordination (EN 50178)
Electric shock protection
Insulation strength
Insulation class
Protection degree
Class of protection
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Installation advice
Status indication
Height x width x depth
Weight
Standards
EMC standards
Approvals
Dimensions
Clamping range (nominal / min. / max.)
mm²
230 V/ 400 V ±15 V
1.8 A/ 1 A
50/ 60 Hz
0.5 A / 0.28 A
3.15 A / 1.6 A time-lag
230 V/ 400 V ±15 V
2.5 A/ 1.3 A
50/ 60 Hz
0.54 A / 0.31 A
4.0 A / 2.0 A time-lag
24 V DC SELV
11 A
10 A
264 W
<5%
Thermostatic switch
Varistor
24 V DC SELV
18 A
15 A
432 W
<5%
Thermostatic switch
Varistor
acc. to BGV A3
4 kV
B
IP 20
I
acc. to BGV A3
4 kV
B
IP 20
I
-20...+55 °C
-20 °C...+80 °C
93%
Direct mounting
Green LED
165 / 120 / 113 mm
6.1 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
CE; cULus; GOSTME25
-20...+55 °C
-20 °C...+80 °C
95%
Direct mounting
Green LED
185 / 135 / 135 mm
9.1 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
CE; cULus; GOSTME25
Input
2.5 / 0.13 / 2.5
Input
2.5 / 0.13 / 2.5
Output
2.5 / 0.5 / 4
Output
2.5 / 0.5 / 4
Note
Ordering data
Screw connection
Type
CP NT 264W 24V 11A
Qty.
1
Order No.
8575310000
Type
CP NT 432W 24V 18A
Qty.
1
Order No.
8575320000
Note
Accessories
Note
D.6
1366860000 – 2013
compactPower 3-phase
CP NT3 250
Unregulated power supplies
compactPower
CP NT3 400
INPUT
+5% 400V -5% +5% 400V - 5% +5% 400V -5%
OUTPUT
3x
=
130°
PE
~
INPUT
+
+
24VDC
-
+5% 400V -5% +5% 400V - 5% +5% 400V -5%
OUTPUT
3x
=
130°
PE
~
+
+
24VDC
-
D
Technical data
Input
Input voltage
Input current
Input frequency
No-load input current
Input fuse
Ext. Back-up fuse
Output
Output voltage
Output current at 40°C / 60°C
Output power
Max. residual ripple
Fusing
Protective circuit, load side
Insulation coordination (EN 50178)
Electric shock protection
Insulation strength
Insulation class
Protection degree
Class of protection
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Installation advice
Fan signal
Height x width x depth
Status indication
Weight
Standards
EMC standards
Approvals
Dimensions
Clamping range (nominal / min. / max.)
mm²
Note
3 x 400 V ±5 %
0.5 A
50/ 60 Hz
0.1 A
3 x primary thermostatic switch
3 x 1.0 A time-lag
3 x 400 V ±5 %
0.75 A
50/ 60 Hz
0.11 A
3 x primary thermostatic switch
3 x 1.2 A time-lag
24 V DC SELV
11 A / 10 A
250 W
<2%
External 10 A time-lag
Varistor
24 V DC SELV
18 A / 16 A
400 W
<2%
External 16 / 18 A slo-blow
Varistor
acc. to BGV A3
4 kV
B
IP 20
I
acc. to BGV A3
4 kV
B
IP 20
I
-20...+60 °C
-20 °C...+80 °C
76%
Direct mounting
No integrated fan
192 / 84 / 185 mm
Green LED
4.7 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
cCSAus; CE; GOSTME25
-20...+60 °C
-20 °C...+80 °C
77%
Direct mounting
No integrated fan
213 / 88 / 220 mm
Green LED
6.9 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
cCSAus; CE; GOSTME25
Input
2.5 / 0.5 / 2.5
Input
2.5 / 0.5 / 2.5
Output
6 / 0.5 / 6
Condensation not allowed
Output
6 / 0.5 / 6
Condensation not allowed
Ordering data
Screw connection
Type
CP NT3 250W 24V 10A
Qty.
1
Order No.
8628620000
Type
CP NT3 400W 24V 15A
Qty.
1
Order No.
8628630000
Note
Accessories
Note
1366860000 – 2013
D.7
Unregulated power supplies
compactPower
compactPower 3-phase
CP NT3 500
CP NT3 600
INPUT
+5% 400V -5% +5% 400V - 5% +5% 400V -5%
OUTPUT
3x
=
130°
PE
~
D
INPUT
+
+
24VDC
-
+5% 400V -5% +5% 400V -5% +5% 400V -5%
OUTPUT
3x
=
130°
M
PE
+
+
24VDC
0V
Fail
~
Technical data
Input
Input voltage
Input current
Input frequency
No-load input current
Input fuse
Ext. Back-up fuse
Output
Output voltage
Output current at 40°C / 60°C
Output power
Max. residual ripple
Fusing
Protective circuit, load side
Insulation coordination (EN 50178)
Electric shock protection
Insulation strength
Insulation class
Protection degree
Class of protection
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Installation advice
Fan signal
Height x width x depth
Status indication
Weight
Standards
EMC standards
Approvals
Dimensions
Clamping range (nominal / min. / max.)
mm²
Note
3 x 400 V ±5 %
0.9 A
50/ 60 Hz
0.13 A
3 x primary thermostatic switch
3 x 1.6 A time-lag
3 x 400 V ±5 %
1.2 A
50/ 60 Hz
0.15 A
3 x primary thermostatic switch
3 x 2 A time-lag
24 V DC SELV
22 A / 20 A
500 W
<2%
External 20 / 22 A slo-blow
Varistor
24 V DC SELV
26 A / 25 A
600 W
<2%
External 25 / 26 A slo-blow
Varistor
acc. to BGV A3
4 kV
B
IP 20
I
acc. to BGV A3
4 kV
B
IP 20
I
-20...+60 °C
-20 °C...+80 °C
78%
Direct mounting
No integrated fan
215 / 108 / 220 mm
Green LED
10 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
cCSAus; CE; cULus; GOSTME25
-20...+60 °C
-20 °C...+80 °C
78%
Direct mounting
Open collector <30 V/ <5 mA during interference
212 / 108 / 230 mm
Green LED
11 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
cCSAus; CE; GOSTME25
Input
2.5 / 0.5 / 2.5
Input
2.5 / 0.5 / 2.5
Output
6 / 0.5 / 6
Condensation not allowed
Output
6 / 0.5 / 6
Condensation not allowed
Ordering data
Screw connection
Type
CP NT3 500W 24V 20A
Qty.
1
Order No.
8628650000
Type
CP NT3 600W 24V 25A
Qty.
1
Order No.
8628660000
Note
Accessories
Note
D.8
1366860000 – 2013
compactPower 3-phase
CP NT3 750
Unregulated power supplies
compactPower
CP NT3 1000
INPUT
+5% 400V -5% +5% 400V -5% +5% 400V -5%
OUTPUT
3x
=
130°
M
PE
0V
Fail
~
INPUT
+
+
24VDC
+5% 400V -5% +5% 400V -5% +5% 400V -5%
OUTPUT
3x
=
130°
M
PE
+
+
24VDC
0V
Fail
~
D
Technical data
Input
Input voltage
Input current
Input frequency
No-load input current
Input fuse
Ext. Back-up fuse
Output
Output voltage
Output current at 40°C / 60°C
Output power
Max. residual ripple
Fusing
Protective circuit, load side
Insulation coordination (EN 50178)
Electric shock protection
Insulation strength
Insulation class
Protection degree
Class of protection
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Installation advice
Fan signal
Height x width x depth
Status indication
Weight
Standards
EMC standards
Approvals
Dimensions
Clamping range (nominal / min. / max.)
mm²
Note
3 x 400 V ±5 %
1.4 A
50/ 60 Hz
0.16 A
3 x primary thermostatic switch
3 x 2.5 A time-lag
3 x 400 V ±5 %
1.8 A
50/ 60 Hz
0.14 A
3 x primary thermostatic switch
3 x 3.15 A time-lag
24 V DC SELV
32 A / 30 A
750 W
<2%
External 30 / 32 A slo-blow
Varistor
24 V DC SELV
42 A / 40 A
1000 W
<2%
External 40 / 42 A slo-blow
Varistor
acc. to BGV A3
4 kV
B
IP 20
I
acc. to BGV A3
4 kV
B
IP 20
I
-20...+60 °C
-20 °C...+80 °C
77%
Direct mounting
Open collector <30 V/ <5 mA during interference
255 / 121 / 270 mm
Green LED
14 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
cCSAus; CE; GOSTME25
-20...+60 °C
-20 °C...+80 °C
77%
Direct mounting
Open collector <30 V/ <5 mA during interference
275 / 122 / 280 mm
Green LED
18 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
cCSAus; CE; GOSTME25
Input
2.5 / 0.5 / 2.5
Input
2.5 / 0.5 / 2.5
Output
6 / 0.5 / 6
Condensation not allowed
Output
10 / 0.5 / 10
Condensation not allowed
Ordering data
Screw connection
Type
CP NT3 750W 24V 30A
Qty.
1
Order No.
8628670000
Type
CP NT3 1000W 24V 40A
Qty.
1
Order No.
8628680000
Note
Accessories
Note
1366860000 – 2013
D.9
D
D.10
1366860000 – 2013
Unregulated power supplies
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Contents
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
1366860000 – 2013
Overview
E.2
FieldPower® switched mode power units
E.6
FieldPower® Control: the modular base
E.8
Housings
E.10
Connection principle
E.13
Contact modules and plug connectors
E.14
Help with project planning
E.20
Drilling template
E.23
Electrical cabinet socket outlet
E.24
E
E.1
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Overview
FieldPower® DC network
With decentralised fuse protection for spur lines
The demand for 24-V current in facilities has grown as
productivity increases. Modular and decentralised topologies
have long been firmly established. Yet the auxiliary power
is still often being generated in the electrical cabinet and
transmitted with significant power loss to the field using
long cables. Standard compliant fuse protection for these
lines is thus repeatedly ignored since such protection is
difficult to implement on such long stretches.
The new FieldPower® switch-mode power supply creates
and protects the current supply directly at the consumer
site. Its many features make it possible to operate highly
dependable and energy efficient DC power networks.
E
E.2
FieldPower® power bus system
Product Information
Decentralised Automation
The full line of FieldPower® products
is listed in our product information.
(Order No.1355570000)
1366860000 – 2013
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Overview
Voltage stability and
supply reliability
Actuating variable and load limit
24 V
24.25
23
23.75 V
U/V
More than just a power supply
This power-bus-compatible power supply unit does not
trigger the 400-V group protective device when reacting
to load current peaks. In addition to the power supply
unit, the FieldPower® Terminal can also be used for
quick and error-free supply to other 400-V consumer
loads.
23.25 V
≤ 300 ms
2
Extended application range
The FieldPower® switch-mode power supply can
be operated in practically any installed position in
temperatures ranging from –30 to 50 °C. It can even be
used in refrigerated warehouses.
Power boost for branch fuse protection
Rail-mounted fuse protection for branches (spurs) can
be installed into the FieldPower® power supply housing.
The power boost from one or more power supplies can
selectively trip the fuse after a short circuit.
Highly reliable power supply
The power supply unit functions even if there is a phase
outage. A power boost (2x IN for 300 ms) is available
for start-up and load currents. A high voltage stability
can be achieved especially when implementing multiple
feeds with a load balancing mechanism.
24 V DC
400 V AC
1366860000 – 2013
Simple
AC and DC are handled identically. The wire is
positioned and contact is established with a simple
turning movement. The 5-pin DC contact module
has two 24 V plus GND for a permanent and safetycompliant power supply, or for minimising voltage drops
with two parallel 6-mm² wire each.
1
0
2.5
5 5.3
7.5
10
12.5
E
I/A
Loadshare Bus
When using multiple power feeds in
decentralised 24-V DC structures, different
loads are placed on the individual power
supply units. Overloads or even outages can
occur as a result. The FieldPower® switchmode power supplies feature passive and
active load balancing mechanisms. An
actuating variable is used to reduce the
voltage as the load increases, so that the
neighbouring components are supported
more strongly. If a power supply unit
exceeds its rated current, the voltage on the
load limit is reduced until the other power
supplies assume this load. Even when in this
operational state, the voltage remains at a high
level. Complete load balancing is achieved
with the point-to-point connections of all load
share bus ports.
DC-power system with FieldPower®
switched-mode power supply units
DC power is distributed in parallel with the
400 V power bus. A uniform voltage level in
the DC distribution (even when using wires
with reduced cross-sections) is made possible
by multiple parallel-fed power supply units
with high IP protection.
E.3
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Overview
FieldPower® Control
Decentralised functional box on the power bus
FieldPower® Control features decentralised and modular
functional components with high IP protection, using the ideal
wire connection technology for AC and DC power supplies.
The FieldPower® power distributor (with IP 54/65) can
function as a decentralised switch box by adding terminals,
electronics housings and switching and protective units.
Many parts of factory automation can thus be decentralised
using an arrangement of application specific modules.
Simple project planning, quick installation, speedy assembly
and good extensibility: these are just some of the advantages
that FieldPower® Control provides for users.
For further information, please visit
www.weidmueller.com/int/Fieldpower_control
E
E.4
1366860000 – 2013
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Overview
Modular components
FieldPower® terminals or a mounting rail can be placed
as needed in the lower section in order to fit the needs
of the individual application. Retractable seals allow
pluggable cables to be inserted quickly.
Application specific solutions
Weidmüller offers not only individual
components but also complete, custom-fit
functional units.
Add-on to lid
Support pegs in the lid help when attaching mounting
plates or rails. The lids also provide plenty of space for
attaching add-on devices or electronic circuit boards.
Variable fastening mechanisms
The mounting rail provides 54 mm of installation width
and can be used at two heights. This creates space for
wires under the mounting rail.
E
Such units include switching devices,
electronic components, terminal strips,
connecting plugs, hinged lids and heat sinks.
Weidmüller can also customise the internal
wiring and the assembly of the connecting
cables to fit customer needs.
Expanded voltage and current ranges
A variety of applications can be implemented with the
help of the FieldPower® Terminals in the AC and DC
versions up to 800 V/41 A.
3∼, N, PE
2 x DC, GND
40,0
35,0
Pvzul [W]
30,0
for outer Tu 25 °C
25,5 W
25,0
20,0
for outer Tu 35 °C
20,1 W
for outer Tu 45 °C
14,8 W
20,1 W
15,0
14,8 W
14,8 W
10,0
9,7 W
9,7 W
0,0
9,7 W
4,7 W
5,0
0
10
20
Max interior Tu 50 °C
30
4,7 W
40
Outer Tu [°C]
Max interior Tu 60 °C
0,0 W
50
Max interior Tu 70 °C
60
70
80
Help with project planning
Simple thermal layout using dimensioned drawings is
possible (see page E.20) and by specifying the built-in
power loss and optimal exploitation of available space.
Max interior Tu 80 °C
Tu max = Max. permitted device temperature
56
159
1366860000 – 2013
4.35
115.4
Please send requests to
[email protected]
7.6
2
46
10
Ø 3.4
Ø 7.8
135
46
6
56
E.5
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
FieldPower® switched mode power units
FieldPower®Box with decentralised switchmode power supply
FieldPower® Box 10P SNT
FieldPower® Box 10P SNT 4XVG
With 4 additional M20 cable glands
• FieldPower Box with three-phase 24 V / 5 A
switch-mode power supply.
• C lose-to-load 24 V power generation and distribution
for decentralised DC-systems
• R educed voltage drops for copper-optimised installations
• More reliable power supply with constant voltage
• Improved energy efficiency with minimal
transmission-related losses
®
L1
L2
L3
PE
+
AC
DC
–
Basic operation is possible with two phases*
E
Technical data FieldPower® Box
Bemmessungsdaten
Rated cross-section
Rated voltage / Rated current
Rated impulse voltage
General data
UL 94 flammability class
Protection degree
Assembly temperature range, min. - max.
Ambient temperature (operational)
IDC connection clamping capacity - power cable
Clamping range, min.-max.
Blade size
PUSH IN connection clamping capacity - distribution
Clamping range, min.-max.
Stripping length/Blade size
Note
6 mm²
800 V / 41 A
8 kV
6 mm²
800 V / 41 A
8 kV
5VA
IP 65
10 °C…40 °C
-30 °C…50 °C
5VA
IP 65
10 °C…40 °C
-30 °C…50 °C
2.5 mm²…6 mm²
0.6 x 3.5 mm
2.5 mm²…6 mm²
0.6 x 3.5 mm
0.75 mm²…6 mm²
14 mm / 0.6 x 3.5 mm
0.75 mm²…6 mm²
14 mm / 0.6 x 3.5 mm
Refer to PT6 DC 1126840000 for additional technical clamping specifications.
Refer to PT6 DC 1126840000 for additional technical clamping specifications.
400...480 V AC** -15 % / +5 % (3∼, PE)
Yes
400...480 V AC** -15 % / +5 % (3∼, PE)
Yes
24.25 V DC ± 50 mV (23.5…28.0 V DC)
5 A @ 24 V DC
10 A, t ≤ 300 ms
Yes
120 W
Input
Output
Plug-in connector
Plug-in connector
L1, L2, L3, PE
+, +, -, -, COM ,NO
0.5 mm²…4 mm²
0.5 mm²…4 mm²
24.25 V DC ± 50 mV (23.5…28.0 V DC)
5 A @ 24 V DC
10 A, t ≤ 300 ms
Yes
120 W
Input
Output
Plug-in connector
Plug-in connector
L1, L2, L3, PE
+, +, -, -, COM ,NO
0.5 mm²…4 mm²
0.5 mm²…4 mm²
* No power boost in two-phase mode or in current-limiting mode.
** UL approval is pending.
* No power boost in two-phase mode or in current-limiting mode.
** UL approval is pending.
Refer to BG SNT PT6 1101940000 for additional technical specifications on the
power supply.
Refer to BG SNT PT6 1101940000 for additional technical specifications on the
power supply.
Type
FP Box 10P SNT
Type
FP Box 10P SNT 4XVG
Technical data power supply
Input data
Rated input voltage
Input fuse (internal)
Output data
Rated output voltage
Rated output current @ Unom
Power boost @ 24 V DC, 0..5A, ED = 10 %, three-phase
Short-circuit-proof
Output power @ 24 V DC
Connection data
Type of connection
Number of terminals
conductor cross-section, min.-max.
Note
Ordering data
Note
Qty.
1
Order No.
1132320000
Qty.
1
Order No.
1076510000
Enclosure seals can be ordered separately.
Enclosure seals (3xD0, 2xD11, 2xD13, 2xD15) and PTDS 4 connector are
included in delivery.
PT6 DC 1126840000 Contact element
PT6 DC 1126840000 Contact element
Accessories
Note
E.6
1366860000 – 2013
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
FieldPower® switched mode power units
BG SNT PT6
Switch-mode power supply 24 V / 5 A
• Three-phase built-in 24 V / 5 A power supply with high
degree of efficiency.
• E xternal heat sink reduces warming within electrical
cabinet.
• R esistant to vibration – in compliance with EN 61373
Cat. 1b for decentralised machine switchboxes.
•W
ide temperature range for versatile use (such as in
refrigerated storage areas)
L1
L2
L3
PE
+
AC
DC
–
Basic operation is possible with two phases*
E
Technical data
Input data
Rated input voltage
AC frequency range
AC current consumption
Start-up surge current / start-up time
Input fuse (internal)
Output data
Rated output voltage
Max. residual ripple, inrush peaks
Output deviation
Rated output current @ Unenn
Power boost @ 24 V DC, 0..5 A, ED = 10%, three-phase
Output characteristic curve / current limit
Short-circuit-proof
Output power @ 24 V DC
Mains buffering @ Inenn
Efficiency
Protection against reverse voltages from the load
General data
Ambient temperature (operational)
Protection class, with PE connection
Surge category / Pollution severity
MTBF according to IEC 1709 (SN29500)
EMC / shock / vibration
Noise emission acc. to EN 55022 (class)
Noise immunity tests
Resistance against vibration and shock
Electrical safety
Electrical machine equipment
For use with electronic equipment
Safety extra-low voltage
Connection data
Type of connection
Number of terminals
conductor cross-section, min.-max.
Note
Ordering data
Note
400…480 V AC** -15 % / +5 % (3∼, PE)
47 Hz - 63 Hz
∼ 0.4 A @ 400 V AC
< 10A @ 400 V AC / < 2 s
Yes
24.25 V DC ± 50 mV (23.5…28.0 V DC)
< 50 mVSS @ 24 V DC / 5 A
500 mV @ 0…5 A
5 A @ 24 V DC
10 A, t ≤ 300 ms
IU, 5.3 A ± 0.2 A
Yes
120 W
20 ms @ 400 V AC
∼ 86 % @ 400 V AC
≤ 34 V
-30 °C…55 °C*
I
III / 2
> 500.000 h @ 25 °C
A
according to EN 61000-6-2
according to EN 61373 Kat. 1b
according to EN 60204
according to EN 50178 / VDE 0160
according to SELV: EN 60950 / PELV: EN 60204
Input
Output
Plug-in connector
Plug-in connector
L1, L2, L3, PE
+, +, -, -, COM ,NO
0.5 mm²…4 mm²
0.5 mm²…4 mm²
* No power boost in two-phase mode or in current-limiting mode.
** UL approval is pending.
Type
BG SNT PT6
Qty.
1
Order No.
1101940000
Assembly accessories are included in delivery.
Accessories
Note
1366860000 – 2013
* Please refer to the derating curve on page 66 for more details.
E.7
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
FieldPower® Control: The modular base
FieldPower® Control: The modular base
Standard components
Lid and functions
Flat lid
1068890000
High lid
1276220000
Lid with maintenance switch
111312000
NEW
E
Housing and seals
Bottom housing
1070140000
Bottom housing with wall feed-through
1272210000
NEW
Plug
Contacts
Single plug
L1, N, L2, PE, L3
1952120000
Double plug
L1, N, L2, PE, L3
1952130000
Fuse plug
L1, N, L2, PE, L3
1961770000
Contact module
L1, N, L2, PE, L3
1957620000
AC labelling
E.8
1366860000 – 2013
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
FieldPower® Control: The modular base
Flat lid
1122200000
High lid
1121950000
Lid with maintenance switch
8000005211
LED lid lighting
1272220000
NEW
Bottom housing
1121980000
Single plug
+1, -1, FE, +2, -2
1131730000
Bottom housing with 4 glands
1121990000
Double plug
+1, -1, FE, +2, -2
1009990000
Fuse plug
+1, -1, FE, +2, -2
1252210000
NEW
Contact module
+1, -1, FE, +2, -2
1126840000
Lid for DIN-rail-mounted devices
8000007627
NEW
Cable seals
various
E
Blank seal
4323240000
Locking element
1816130000
Snap on DIN rail,
54 mm
1170690000
DC labelling
1366860000 – 2013
E.9
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Housings
E
Housings
GH 10P PT6
BG GH 10P 4XVG PT6
With 4 additional M20 cable glands
The housings can be assembled during the mechanical
work.
The PT6 contact unit is simply snapped on with or without
a power bus.
The TS 35 PT6 DIN-rail module can be used optionally.
Technical data
Insulating material
Material colour
UL 94 flammability class
Halogen free / Silicone free
Degree of protection when closed
Temperature range / storage
Lid attachment
Housing attachment
PC GF 10
black
5VA
Yes / Yes
IP 65
-40 °C…55 °C / -40 °C...85 °C
Screws
Mounting tabs
PC GF 10
black
5VA
Yes / Yes
IP 65
-40 °C…55 °C / -40 °C...85 °C
Screws
Mounting tabs
Note
Clamping range of the cable glands 6–12 mm
Ordering data
Type
GH 10P PT6
Note
Qty.
10
Order No.
1121980000
Housing lid BG GHDE 10P PT6 1122200000
Housing lid BG GHDE 10P HO PT6 1121950000
Type
BG GH 10P 4XVG PT6
Qty.
10
Order No.
1121990000
Qty.
10
Order No.
1170690000
Housing lid BG GHDE 10P PT6 1122200000
Housing lid BG GHDE 10P HO PT6 1121950000
Accessories
Type
TS 35 PT6
Note
E.10
Qty.
10
Order No.
1170690000
Usable width 54 mm
Can be installed in 1070140000, 1121980000, 1121990000
Type
TS 35 PT6
Usable width 54 mm
Can be installed in 1070140000, 1121980000, 1121990000
1366860000 – 2013
Lid
BG GHDE 10P PT6
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Housings
BG GHDE 10P HO PT6
FieldPower lids are very sturdy and meet the highest UL
flammability rating 5VA. The large number of varieties
means you can install the devices on DIN mounting rails or
mounting plates.
®
67
164
192
181
181
192
E
Technical data
Insulating material
Material colour
UL 94 flammability class
Halogen free / Silicone free
Degree of protection when closed
Temperature range / storage
Lid attachment
PC GF 10
black
5VA
Yes / Yes
IP 65
-40 °C…55 °C / -40 °C...85 °C
Screws
PC GF 10
black
5VA
Yes / Yes
IP 65
-40 °C…55 °C / -40 °C...85 °C
Screws
Note
Housing height: 67 mm
Housing height: 164 mm
Refer to the project planning documentation for the detailed dimensions
Ordering data
Note
Type
BG GHDE 10P PT6
Qty.
10
Order No.
1122200000
Housing base section GH 10P PT6 1121980000
Housing base section BG GH 10P 4XVG PT6 1121990000
Type
BG GHDE 10P HO PT6
Qty.
10
Order No.
1121950000
Housing base section GH 10P PT6 1121980000
Housing base section BG GH 10P 4XVG PT6 1121990000
Accessories
Note
1366860000 – 2013
E.11
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Housings
Seals for FieldPower® Box
Seal for round cable
Blanking seal
IP 65 enclosure seals for the FieldPower Box modules:
made from silicone-free, halogen-free material. The seals
are slit in the middle to allow for simple installation with
uncut power cables.
®
ø
E
Technical data
General data
Material
UL 94 flammability class
Colour
Thickness
Line type
Free from halogens
Silicone-free
Ingress protection class
EPDM
HB
black
18 mm
round
Yes
Yes
IP 65
EPDM
HB
black
18 mm
Yes
Yes
IP 65
Note
Ordering data
Clamping range Ø
7.5 - 9 mm
9 - 11 mm
11 - 13 mm
13 - 15 mm
15 - 17 mm
Type
RKDG D9 PT6
RKDG D11 PT6
RKDG D13 PT6
RKDG D15 PT6
RKDG D17 PT6
Qty.
10
10
10
10
10
Order No.
4329610000
4323210000
4323230000
4323220000
4324010000
Type
DG D0 PT6
Qty.
10
Order No.
4323240000
Note
Accessories
Note
E.12
1366860000 – 2013
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
The method of connection
FieldPower® – The method of connection
1
2
3
0.6 Nm
0
13
m
m
E
4
5
6
90°
Klick
Klick
IDC
2.5...6 mm2
7
8
2.0 Nm
?
A practical tip
FieldPower® is the best solution
when the cable is too short.
The cable need only be stripped and not cut
through. No mix-ups or wrong connections
are possible. This is also a perfect solution for
retrofit installations.
An installation video can be seen at
www.weidmueller.com/de/FieldPower_Video
1366860000 – 2013
E.13
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Contact modules and plug connectors
PowerTerminal for AC/DC applications
A contact element for power distribution using uncut wires
with cross-sections from 1.5 to 6 mm². Feed-in / T-branch
tap via PUSH IN connection (0.5 to 10 mm²) and/or
plug-in connection (0.5 to 4 mm²).
Clear and precise wire assignments: with coding on the PE
connection.
PT6
PT6 DC
for AC applications
for DC applications
• Power supply
• Power distribution
• Power branching
{
61.5
E
DC labelling
AC labelling
53.9
139.5
Technical data
Rated data according to IEC 60947-7-1
Rated cross-section
Rated voltage/Rated current
Rated impulse voltage
General data
Insulation material/material colour
UL 94 flammability class
Free from halogens/Silicone-free
Protection degree
Assembly temperature range, min.-max.
Operating temperature, min.-max.
Can be coded
IDC connection clamping capacity - power cable
Solid, min.-max.
Stranded, min.-max.
Flexible, min.-max.
Flexible, min.-max.
Blade size
PUSH IN connection clamping capacity - distribution
Solid, min.-max.
Stranded, min.-max.
Flexible, min.-max.
Flexible, wire end ferrule 8 mm, DIN 46228/1, min-max.
Flexible, wire end ferrule 8 mm, DIN 46228/4, min-max.
Flexible, wire end ferrule 12 mm, DIN 46228/1, min-max.
Flexible, wire end ferrule 12 mm, DIN 46228/4, min-max.
Flexible, min.-max.
Stripping length/Blade size
Rated data according to UL
Standard
Rated voltage/Rated current
AWG conductor (field wiring) min./max.
Note
Note
Ordering data
6 mm²
800 V / 41 A
8 kV
6 mm²
800 V / 41 A
8 kV
PA/grey
V0
Yes/Yes
IP 20
10 °C...40 °C
-40 °C...55 °C
Yes/Coded on PE
PA/grey
V0
Yes/Yes
IP 20
10 °C...40 °C
-40 °C...55 °C
Yes/Coded on PE
1.5 mm²…6 mm²
2.5 mm²…6 mm²
2.5 mm²…6 mm²
2.5 mm²…6 mm²
0.6 x 3.5 mm
1.5 mm²…6 mm²
2.5 mm²…6 mm²
2.5 mm²…6 mm²
2.5 mm²…6 mm²
0.6 x 3.5 mm
0.5 mm²…6 mm²
0.5 mm²…6 mm²
0.5 mm²…10 mm²
0.5 mm²…6 mm²
0.5 mm²…6 mm²
0.5 mm²…6 mm²
0.5 mm²…6 mm²
0.5 mm²…6 mm²
14 mm / 0.6 x 3.5 mm
UL 1059
600 V/30 A
14 /10
For use with UL-listed TC-ER cables
0.5 mm²…6 mm²
0.5 mm²…6 mm²
0.5 mm²…10 mm²
0.5 mm²…6 mm²
0.5 mm²…6 mm²
0.5 mm²…6 mm²
0.5 mm²…6 mm²
0.5 mm²…6 mm²
14 mm / 0.6 x 3.5 mm
UL approval is pending.
UL 1059
600 V/30 A
14 /10
For use with UL-listed TC-ER cables
Tip: Pipe Ölflex Classic 100, 110, 100 H or comparable
Tip: Pipe Ölflex Classic 100, 110, 100 H or comparable
Type
PT6
Qty.
1
Order No.
1957620000
Type
PT6 DC
Qty.
1
Order No.
1126840000
Note
Accessories
Note
E.14
Plug-in connector PTS 4 1952120000
Plug-in connector PTDS 4 1952130000
Plug-in connector PTS 4 DC 1131730000
Plug-in connector PTDS 4 DC 1009990000
1366860000 – 2013
PowerTerminal for AC/DC applications
A contact element for power distribution using uncut wires
with cross-sections from 1.5 to 6 mm². Feed-in / T-branch
tap via PUSH IN connection (0.5 to 10 mm²) and/or
plug-in connection (0.5 to 4 mm²).
Coloured markings for unambiguous wire assignments
according to DIN VDE 0293-308.
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Contact modules and plug connectors
PT6 230/…
For mixed applications
• Power supply
• Power distribution
• Power branching
Black
Snap-on mounting rail
Blue
Yellow/Green
53.9
61.5
Brown
139.5
Colour coding
DIN VDE 0293-308
Grey
E
Technical data
Rated data according to IEC 60947-7-1
Rated cross-section
Rated voltage/Rated current
Rated impulse voltage
General data
Insulation material/material colour
UL 94 flammability class
free from halogens/Silicone-free
Protection degree
Assembly temperature range, min.-max.
Operating temperature, min.-max.
Can be coded
IDC connection clamping capacity - power cable
Solid, min.-max.
Stranded, min.-max.
Flexible, min.-max.
Flexible, min.-max.
Blade size
PUSH IN connection clamping capacity - distribution
Solid, min.-max.
Stranded, min.-max.
Flexible, min.-max.
Flexible, wire end ferrule 8 mm, DIN 46228/1, min-max.
Flexible, wire end ferrule 8 mm, DIN 46228/4, min-max.
Flexible, wire end ferrule 12 mm, DIN 46228/1, min-max.
Flexible, wire end ferrule 12 mm, DIN 46228/4, min-max.
Flexible, min.-max.
Stripping length/Blade size
Rated data according to UL
Standard
Rated voltage/Rated current
AWG conductor (field wiring) min./max.
Note
Note
Ordering data
6 mm²
800 V / 41 A
8 kV
The mounting rail TS 35 PT6 provides 54 mm of
installation width and can be used at two heights.
This creates space for wires under the mounting rail.
PA/grey
V0
Yes/Yes
IP 20
10 °C...40 °C
-40 °C...55 °C
Yes
54 mm
1.5 mm²…6 mm²
2.5 mm²…6 mm²
2.5 mm²…6 mm²
2.5 mm²…6 mm²
0.6 x 3.5 mm
0.5 mm²…6 mm²
0.5 mm²…6 mm²
0.5 mm²…10 mm²
0.5 mm²…6 mm²
0.5 mm²…6 mm²
0.5 mm²…6 mm²
0.5 mm²…6 mm²
0.5 mm²…6 mm²
14 mm / 0.6 x 3.5 mm
UL approval is pending.
UL 1059
600 V/30 A
14 /10
For use with UL-listed TC-ER cables
✓
✓
M≤
0.4
kg
M≤
0.4
kg
CLICK
Tip: Pipe Ölflex Classic 100, 110, 100 H or comparable
CLICK
Type
PT6 230/BUS
Qty.
1
Order No.
1269960000
1121980000
1121990000
Note
Accessories
Note
1366860000 – 2013
Plug-in connector PTS 4 MBP 1010190000
E.15
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Contact modules and plug connectors
Plug-in connectors for AC applications
PTS 4
PTDS 4
2 connections per pole
Plug-in connectors for use by the pluggable output of the
contact elements. Individual wires can be connected with
PUSH IN method: for cross-sections from 0.5 to 4 mm².
Can be coded and locked, with printing for trouble-free
wiring.
Clear wire mapping with coding for PE connections.
{
E
27.3
27.3
22
55.45
36.15
22
36.15
55.45
{
Technical data
Rated data according to IEC 60947-7-1
Rated cross-section
Rated voltage/Rated current
Rated impulse voltage
General data
Type of mounting
Insulation material/material colour
UL 94 flammability class
Continuous operating temp., min.-max.
Outgoing direction of conductor
Test point
Can be coded
Conductor connection system
No. of poles
Number of connections / pole
Clamping capacity, PUSH IN connection
Clamping range, min.-max.
Solid, min.-max.
Stranded, min.-max.
Flexible, min.-max.
Flexible, wire end ferrule 8 mm, DIN 46228/1, min.-max.
Flexible, wire end ferrule 8 mm, DIN 46228/4, min.-max.
Flexible, wire end ferrule 12 mm, DIN 46228/1, min.-max.
Flexible, wire end ferrule 12 mm, DIN 46228/4, min.-max.
Flexible, min.-max.
Stripping length/Blade size
Rated data according to UL
Standard
Rated voltage/Rated current
AWG conductor (field wiring) min./max.
4 mm²
690 V / 32 A
8 kV
4 mm²
690 V / 32 A
8 kV
Plugged
PA GF/ black
V0
-50 °C...120 °C
90°
2 mm
Yes/Coded on PE
PUSH IN
5
1
Plugged
PA GF/ black
V0
-50 °C...120 °C
90°
2 mm
Yes/Coded on PE
PUSH IN
5
2
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
12 mm / 3.0 x 0.5 mm
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
12 mm / 3.0 x 0.5 mm
UL 1059
600 V/20 A
16 /12
UL 1059
600 V/20 A
16 /12
Note
Ordering data
Type
PTS 4
Qty.
10
Order No.
1952120000
Type
PTDS 4
Qty.
10
Order No.
1952130000
Note
Accessories
Note
E.16
ZVR ZP2.5 locking element 1816130000
ZVR ZP2.5 locking element 1816130000
1366860000 – 2013
PTS 4 DC
PTDS 4 DC
2 connections per pole
Plug-in connectors for use with the pluggable outlet of the
PT6 contact elements. Single-wire PUSH IN connection for
wire cross-sections ranging from 0.5 to 4 mm².
Can be coded and latched down.
Clear wire mapping with DC labelling and coding for PE
connections.
27.3
27.3
55.45
36.15
22
36.15
55.45
22
Plug-in connectors for DC applications
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Contact modules and plug connectors
E
Technical data
Rated data according to IEC 60947-7-1
Rated cross-section
Rated voltage/Rated current
Rated impulse voltage
General data
Type of mounting
Insulation material/material colour
UL 94 flammability class
Continuous operating temp., min.-max.
Outgoing direction of conductor
Test point
Can be coded
Conductor connection system
No. of poles
Number of connections / pole
Clamping capacity, PUSH IN connection
Clamping range, min.-max.
Solid, min.-max.
Stranded, min.-max.
Flexible, min.-max.
Flexible, wire end ferrule 8 mm, DIN 46228/1, min.-max.
Flexible, wire end ferrule 8 mm, DIN 46228/4, min.-max.
Flexible, wire end ferrule 12 mm, DIN 46228/1, min.-max.
Flexible, wire end ferrule 12 mm, DIN 46228/4, min.-max.
Fexible, min.-max.
Stripping length/Blade size
Rated data according to UL
Standard
Rated voltage/Rated current
AWG conductor (field wiring) min./max.
Note
Ordering data
4 mm²
690 V / 32 A
8 kV
4 mm²
690 V / 32 A
8 kV
Plugged
PA GF/ black
V0
-50 °C...120 °C
90°
2 mm
Yes/Coded on PE
PUSH IN
5
1
Plugged
PA GF/ black
V0
-50 °C...120 °C
90°
2 mm
Yes/Coded on PE
PUSH IN
5
2
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
12 mm / 3.0 x 0.5 mm
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
12 mm / 3.0 x 0.5 mm
UL 1059
600 V/20 A
16 /12
UL 1059
600 V/20 A
16 /12
UL approval is pending.
UL approval is pending.
Type
PTS 4 DC
Qty.
10
Order No.
1131730000
Type
PTDS 4 DC
Qty.
10
Order No.
1009990000
Note
Accessories
Note
1366860000 – 2013
ZVR ZP2.5 locking element 1816130000
ZVR ZP2.5 locking element 1816130000
E.17
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Contact modules and plug connectors
Plug-in connectors for mixed applications
PTS 4 blank
Plug-in connector for use by the pluggable output of the
contact elements. Individual wires can be connected with
PUSH IN method: for cross-sections from 0.5 to 4 mm².
Can be coded and locked.
E
27.3
22
36.15
55.45
Technical data
Rated data according to IEC 60947-7-1
Rated cross-section
Rated voltage/Rated current
Rated impulse voltage
General data
Type of mounting
Insulation material/material colour
UL 94 flammability class
Continuous operating temp., min.-max.
Outgoing direction of conductor
Test point
Can be coded
Conductor connection system
No. of poles
Number of connections / pole
Clamping capacity, PUSH IN connection
Clamping range, min.-max.
Solid, min.-max.
Sstranded, min.-max.
Flexible, min.-max.
Flexible, wire end ferrule 8 mm, DIN 46228/1, min.-max.
Flexible, wire end ferrule 8 mm, DIN 46228/4, min.-max.
Flexible, wire end ferrule 12 mm, DIN 46228/1, min.-max.
Fflexible, wire end ferrule 12 mm, DIN 46228/4, min.-max.
Flexible, min.-max.
Stripping length/Blade size
Rated data according to UL
Standard
Rated voltage/Rated current
AWG conductor (field wiring) min./max.
4 mm²
690 V / 32 A
8 kV
Plugged
PA GF/ black
V0
-50 °C...120 °C
90°
2 mm
YES / Not coded
PUSH IN
5
1
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
12 mm / 3.0 x 0.5 mm
UL 1059
600 V/20 A
16 /12
Note
Ordering data
Type
PTS 4 MPB
Qty.
10
Order No.
1010910000
Note
Accessories
Note
E.18
ZVR ZP2.5 locking element 1816130000
1366860000 – 2013
Fuse plug-in connector
Max. power loss for G fuse terminals
in accordance with IEC 60947-7-3:
•Overload protection: 1.6 W (at 1.5 x IN)
•Short-circuit protection: 4 W (at 1.5 x IN)
Max. power loss per fuse at 23 °C Tu.
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Contact modules and plug connectors
PTSI 4 / PTSI 4/ LD
{
Do not exceed the max. power loss when selecting fuse
cartridges. When a fuse is defective, the subsequent circuit
is not voltage free.
for AC applications
for DC applications
A practical tip:
Space for spare fuses
Rated data according to IEC 60947-7-3
Rated cross-section
Rated voltage/Rated current (as disconnect terminal)
Rated impulse voltage
General data
Cartridge fuse
Outage display
Type of mounting
Insulation material/material colour
UL 94 flammability class
Continuous operating temp., min.-max.
Outgoing direction of conductor
Test point
Can be coded
Conductor connection system
No. of poles
Number of connections / pole
Clamping capacity, PUSH IN connection
Clamping range, min.-max.
Solid, min.-max.
Stranded, min.-max.
Flexible, min.-max.
Flexible, wire end ferrule 8 mm, DIN 46228/1, min.-max.
Flexible, wire end ferrule 8 mm, DIN 46228/4, min.-max.
Flexible, wire end ferrule 12 mm, DIN 46228/1, min.-max.
Flexible, wire end ferrule 12 mm, DIN 46228/4, min.-max.
Fexible, min.-max.
Stripping length/Blade size
Rated data according to UL
Standard
Rated voltage/Rated current
AWG conductor (field wiring) min./max.
Note
Ordering data
PTSI 4...AC
E
PTSI 4...DC
4 mm²
500 V / 12 A
6 kV
4 mm²
36 V / 12 A
6 kV
6.3 x 32 mm (1/4 x 1 1/4")
LED red
Plugged
PA GF/ black
V0
-50 °C...120 °C
90°
2 mm
Yes/Coded on PE
PUSH IN
5
1
6.3 x 32 mm (1/4 x 1 1/4")
LED red
Plugged
PA GF/ black
V0
-50 °C...120 °C
90°
2 mm
Yes/Coded on PE
PUSH IN
5
1
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
12 mm / 3.0 x 0.5 mm
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
0.5 mm²…4 mm²
12 mm / 3.0 x 0.5 mm
UL 1059
600 V/20 A
16 /12
–
–
–
Note
IP 20
IP 65
Only short-circuit
Overload and
protection
short-circuit protection
TA max. Nominal values TA max. Nominal values
46 °C
4.0 W / 10 A 28 °C 2.5 W / 2.5 A
23 °C
4.0 W / 10 A 39 °C 1.6 W / 1.0 A
Fuses and power loss:
Examples
Current 1.0 A 1.6 A 2.0 A 4 A 6.3 A 8 A 10 A 12.5 A
SIBA, 189140
1.0 x IN 0.35 W 0.32 W 0.36 W 0.56 W 0.69 W 0.88 W 1 W
500 V,
440 V, 250 V
1.5 x IN 0.9 W 1.1 W 1.2 W 1.5 W 2.2 W 2.6 W 3.0 W
T
SIBA,
1.0 x IN – – – – 1.2 W 1.5 W 1.8 W
7006584
400 V
1.25 x IN – – – – 2.5 W 3.2 W 3.7 W
gRL
No responsibility is taken for the accuracy of this information.
Further details can be obtained from the fuse manufacturers.
1.25 W
3.5 W
1.9 W
3.9 W
Derating curve for IP 65 use:
Safety fuse not included in delivery.
Rated voltage and rated current with fuse are determined by the G-fuse cartridge
in use.
Type
PTSI 4/LD 400V AC
PTSI 4/LD 36V AC/DC
Protection
degree
Qty.
1
1
Order No.
1961770000
1252210000
Power loss P [W] bei I = 1,5 x IN
Technical data
4,5
4
3,5
3
2,5
2
1,5
1
0,5
0
0
10
20
30
40
50
60
70
80
90
100 110 120
Ambient temperature T [°C]
Only short-circuit protection
Overload and short-circuit protection
Accessories
Note
1366860000 – 2013
ZVR ZP2.5 locking element 1816130000
E.19
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Help with project planning
Help with project planning
FieldPower® Control
CAD models can be found in our online catalogue at
http://catalog.weidmueller.com
BG GHDE HO PT6
BG GHDE 10P HO PT6
PTS 4...
PT6...
GH PT6
GH 10P PT6
E
BG GHDE HO PT6
BG GHDE 10P HO PT6
PTS 4...
PT6...
GH PT6
GH 10P PT6
23
75
72.2
78.5
GHDE 10P HO ON/OFF PTS4
BG GHDE HO SA UL PT6
PT6...
GH PT6
GH 10P PT6
34.7
44.5
34.7
56.5
66
64
BG GHDE HO PT6
BG GHDE 10P HO PT6
TS 35 PT6
GH PT6
GH 10P PT6
38.4
20
4.35
7.6
77
73
34.7
56.5
E.20
115.4
Ø 3.4
Ø 7.8
164
87
84
66
54
65
6
65.5
1366860000 – 2013
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Help with project planning
BG GHDE 10P HO PT6
84
87
160.5
56
E
46
1.5 ± 0.3 Nm
135
10
46
56
Ø8
Ø 3.4
6
5.7 ± 0.1
2
Ejot Delta
PT WN5412 H 40x...
159
Screw-in depth
TS 35 PT6
GH 10P PT6
33.5
54.5
1
0
45 ±0.5
45
55
6.8
≤ 44
40
8.5
46.5
68
68
58
68
8.5
68
583
58
mm
Pos. 2
1x
40
50
>2
click
≤ 82
0
≤ 67
0
45
6.9
55
43
45
0
0
54.5
43
1
1
1
0
55
43
BG GHDE 10P REG
54.5
1
1
35
8.5
≤ 55
46.5
≤ 55
152
1,5 Nm
1366860000 – 2013
Pos. 3
E.21
Help with project planning
FieldPower® DC-Network
U/V
23.75 V
23.25 V
Input 400 V ∼
L1, L2, L3, h
0.5…4 mm2
0.4…0.5 Nm
SD 0.6 x 3.5 x 100
≤ 300 ms
E
1
0
2.5
5 5.3
7.5
10
#2
#6
LS+
LS-
LOAD SHARE
0.2…1.5 mm2
0.2…0.25 Nm
SD 0.4 x 2.5 x 75
Fault Relay ≤ 1 A / 24 V
COM, NO
Output 24 V DC 5 A
+, +, -, -
2
#1
LSLSLS+
LS+
24 V
24.25
23
Loadshare Bus
LSLSLS+
LS+
Actuating variable and load limit
LSLSLS+
LS+
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Help with project planning
LOAD SHARE bus connection:
twisted pair cable
(for example, Ölflex)
12.5
I/A
Installed position
≥ 15 mm
a)
b)
≥ 15 mm
c)
d)
Ø 6…12 mm
59.4
47.7
Power in W
Derating curve
150
P
140 max
130
120 Prated
110
100
90
80
70
60
50
40
30
20
10
0
0
a)
c)
d)
b)
10
20
30
40
50
60
70
80
Tu in °C
E.22
1366860000 – 2013
1366860000 – 2013
192
177
192
FieldPower® Box 10P
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Drilling template
E
165
181
E.23
IP 65 switched-mode power supply /
Electrical cabinet socket outlet
Electrical cabinet socket outlet
Electrical cabinet socket outlet
Schuko TS35
• S imple installation in electrical cabinet
• T S35 module can be mounted on rail
• V DE mark of conformity
• T wo-pole with earthing contact
Technical data
E
Rated voltage
Rated voltage, max.
Rated current
Clamping range, nom.
Tightening torque
Ambient temperature (operational)
Surge voltage category
Pollution severity
Protection degree
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Height x width x depth
Note
230 V
250 V
16 A
1 mm² - 1,5 mm²
1.3 Nm
-20...+40 °C
II
2
IP 20
CE; VDE
mm²
1.5 / 1 / 1.5
45 / 76 / mm
Ordering data
Type
Schuko TS35
Qty.
10
Order No.
8734580000
Note
Accessories
Note
E.24
1366860000 – 2013
Weidmüller Solutions & Service
Contents
Weidmüller Solutions & Service
Weidmüller Solutions & Service
Customer specific solutions: best advice, best solutions
V.2
Digital support: RailDesigner , Product Assistant for Distribution Boxes,
Online product catalogue, M-Print® PRO label designer
V.8
®
V
1366860000 – 2013
V.1
Weidmüller Solutions & Service
Customer specific solutions
Application specific solutions –
Your requirements are our motivation
Each industry has its own requirements calling for more and
more individual solutions aside from standard products. Your
new product might have to contend with severe conditions.
In addition, many applications are subjected to high
mechanical strains – through vibration or directly applied
forces. Extreme temperature conditions or an application in
hazardous areas are further factors you will need to take into
account, and your product must comply with the appropriate
standards for these conditions. We can offer you highly
competent expertise to support you in the selection of ideal
products, whatever your application. Feel free to contact us!
Individual product development
Working closely with you, we can develop individual and
future-proof products using the latest technologies and
which are specifically tailored to your application.
From custom product development, customer-specific
assembly or application-specific products that are ready for
use - we can help you to optimise your working processes
and ensure your company‘s sustained efficiency, today, as
well as for the future.
Application-specific products
Our cross-industrial solutions set standards: Set up for your
application, instantly ready for use and available from stock.
Customer-specific assembly
Our highly-skilled production expertise and broad product
portfolio means that we can deliver superior solutions to
meet and exceed your specification requirements.
V
V.2
1366860000 – 2013
Weidmüller Solutions & Service
Customer specific solutions
Individual product development for your success
We have a passion for simple, innovative solutions
Working with you, we can develop innovative and
future-oriented products tailored to your application.
Our philosophy is „one customer - one product“. It is not the
product that is the starting point, but you, your technical
specifications and your requirements.
A connecting partnership
The development of individual products means making
the most of the experience and competencies available
in the partnership. Our project management provides a
professional and quality approach - from concept and design
through to development, implementation and production.
Our extensive knowledge of electrical connectivity, enclosure
and sealing technology, as well as signal conditioning, are all
at your disposal.
Benefit from a reliable partner:
•Increase the efficiency of your development and
production processes
Outsourcing the development and production of
your components will shorten your time-to-market. In
addition, you have more time to concentrate on your core
competencies.
•Take advantage of our applications and production
expeience and expertise
You can draw on the accumulated knowledge of our
applications engineers and our specialists in the fields of
connection technology, enclosure and surface technology,
as well as metal and plastic processing, which is second
to none.
•Feel safe with the professional approach of our
project management
Through innovation workshops, feasability studies and
profitability analyses we define a requirement profile
forming the basis for the further development process.
In this way, you can be sure of the best possible products
for your needs.
V
1366860000 – 2013
V.3
Weidmüller Solutions & Service
Customer specific solutions
Application specific products –
solutions for industries and markets
Industries and applications often have similar or even
identical requirements for products or product assemblies.
Application specific products that are based on earlier
realised solutions are now directly available from stock.
Your advantage: You quickly get a suitable and
cost-efficient solution.
Cross industrial solutions as standard
It is our aim to develop solutions that offer the additional
advantage of a truly flexible design. Although this may mean
an application-specific product may have an additional input
or terminal you don‘t need, it can still be much cheaper than
having a custom-made solution. Therefore, you not only save
time, but money!
Reap multiple benefits:
•High availability
Application specific products are available from stock
without delay. So you can rely on the delivery of your
products when you need them.
•Advice from application engineers
Using the expertise of our applications engineers means
that you can develop solutions that are not only right, but
which deliver added value to your applications.
•Supportive software
Project planning and evaluation is made easy with our
software solutions such as NetCalc®, RailDesigner® or
Softclinic.
•Worldwide application centres
We stay in constant dialogue with our worldwide
application centres, ensuring that our own application
knowledge is shared, kept up to date and at your disposal
anywhere you need us.
V
V.4
1366860000 – 2013
Customer specific assembly,
tailored configuration
You may be looking to bring costs down and increase your
efficiency. It may be that you would like more time to focus
on your core competencies. You could be looking for a
partner who will set up intelligent solutions for you, and who
you can trust to deliver your specific requirements. Here
at Weidmüller, we have a wealth of expertise, capability,
and capacity to deliver custom solutions that are flexible,
economically advantageous and on time.
We offer to work closely with you, providing support
and advice, and in putting together the job specification.
Furthermore, our broad product portfolio means that we
can jointly work together on the selection of the best
components to make up your custom solution.
Take advantage of:
•Simple ordering and stockholding information
One solution – one item number! It will no longer be
necessary to order single components. Article variety and
stockholding will be reduced.
•Professional assembly
All individual components will be pre-assembled, reducing
your own assembly time and costs.
1366860000 – 2013
Weidmüller Solutions & Service
Customer specific solutions
T
Highest levels of professional production
You have complete access to our highly-skilled project
management team and our production expertise,
for example, in the ATEX area. We can offer you a
comprehensive portfolio of customer-specific assemblies,
from simple assembly to the modification of existing
electronics products.
Our services include:
•Adaptation and assembly of enclosures for all
IP protection classes
• ATEX solutions for hazardous areas
• Assembly of heavy duty connectors
• Assembly of terminal strips
• Customer specific electronics solutions
• Cable assembly
•Less costs for documentation
Our RailDesigner® software will facilitate the generation of
parts lists or drawings.
•Modern processing of enclosures
Our CNC processing centres can adapt the enclosures to
suit your tailored solution.
V
V.5
Weidmüller Solutions & Service
Customer specific solutions
Customer specific assembly — consultation, product,
development and production – all from a single source
Our application and manufacturing expertise influences
decisions on all areas of modern connection technology.
They therefore play an integral part of every solution.
Enclosures
Perfect protection and safety
• Enclosures for all IP protection classes
• ATEX enclosures for hazardous areas
• Placement of inspection glasses, drill holes and threads
•Elaborate machining operations like the milling of
contours
•Class C5 welding, according to DIN 6700, for stainless
steel and sheet steel enclosures
• Surface coating as and when required
• Individual device and system markers
T
Heavy duty connectors
Perfect connection with system
• Placement of drill holes and cable glands
• Equipped with plug-and-play components
• Wiring of sub-assemblies
• Cable assembly
• All housings are available with individual laser marking
Terminal strips
Configuration made to measure
• Machining of mounting rails
• Snapping components onto terminal rails
• Placement of cross connections
• Mounting of standard conductors
• Marking of terminals, devices, conductors and cables
V
V.6
1366860000 – 2013
Weidmüller Solutions & Service
Customer specific solutions
Electronics
Individual solution from the beginning
•Modular terminal blocks, component plugs, snap on
bases, enclosures for electronics: integration of relevant
electronic components
•Snap-on base: Component carrier design or simple wiring
of the modules
• Interface units
•Modification of existing electronic products: modification
of the circuitry or specific calibration
•Combination of components: relays or optocouplers in
combination with other components
Cable assembly
Our special service
•Pre-cutting of cables and conductors
•Installation of
- Heavy duty connectors
- PCB connectors or DIN connectors
•Conditioning of wire ends
•Mounting of wire end ferrules and cable lugs
•Connection of conductors to terminal rails
V
1366860000 – 2013
V.7
Weidmüller Solutions & Service
Digital support
RailDesigner®
A faster way to configure and order terminal strips
These days, time and cost efficiency are of the essence
when it comes to working in planning and production.
RailDesigner®, our free configuration and purchasing
software, uses its virtual assembly of mounting rails
(assembled or unassembled) to help you with the design of
your own, completely personal solution.
RailDesigner® brings you substantial benefits:
Less time required
It speeds up the process of acquiring quotations and placing
orders because, for example, all processes can be initiated
directly from the software. You configure your projects and
the rest virtually takes care of itself!
User friendly operation
Any potential errors are prevented by automatic installation
tips and clear project processing and management. So that
you can plan your project realistically, RailDesigner® offers
both 2D and 3D displays.
V
Wide selection from the current product portfolio
You can easily download software updates for RailDesigner®
from the internet. This means that you will always have
access to the latest version of our product database.
Project planning that is compatible with your
software
Plan and design your projects easily using your usual CAE
software. With the integrated interface, transferring data
from your CAE system has never been so simple. You can
export component lists and terminal strip designs in various
formats. Marking data is automatically transferred to the
M-Print® Pro labelling software.
Simple purchasing of terminal strips
Once you have completed the planning stages of your
projects in RailDesigner®, you can choose to send all of your
data to us by email. Then we take over the assembly and
deliver the required configuration to you, along with anything
else that you still require for your project.
Download the software for free and discover the advantages
to using RailDesigner® at www.raildesigner.de
V.8
1366860000 – 2013
Weidmüller Solutions & Service
Digital support
Product assistant for distribution boxes and assemblies –
The perfect solution, in the shortest time
You can easily and quickly select, combine and purchase the
required components, all with the help of the Weidmüller
product assistant for distribution boxes and assemblies.
This means that you can rapidly obtain your individual
enclosure solutions which may include the following
components:
Empty enclosures without holes
Empty enclosures in various sizes of the Klippon® K and
Klippon® POK series (aluminium and plastic) with matching
mounting rails.
Empty enclosures with pre-threaded holes
Empty enclosures in different sizes from the Klippon® K and
Klippon® POK series (aluminium and plastic), that are already
equipped with metric threaded holes.
Mounting rails
Exactly tailored mounting rails for the enclosure sizes on
offer.
Terminal strips
Mounting rails, which also perfectly match the offered
enclosure sizes and are pre-fitted with terminals, optionally
with screw or tension clamp connection.
Distribution boxes with Ex-protection
Enclosures that are already assembled with a terminal strip
and already equipped with metric threaded holes.
1366860000 – 2013
Numerous possible combinations
Enclosures with Ex-protection are supplied exclusively with
terminal strips that are already fitted. The product assistant
offers you various approaches for industry variants so that
you can create the right enclosure variant.
You can start off with any of the listed components and then
add further components to the combination. This means
that, for example, you can select the required terminal
strip and the product assistant will then offer the matching
enclosure variants.
Or, you can start with the enclosure, and matching terminal
strips or mounting rails will then be chosen. The selected
products can then be directly included in the query list.
Provision of all relevant data
During the selection, you can choose filters for the
terminal strips, such as length, connection technology or
dimensional cross-section and, for the enclosure, you can
choose material, size, holes etc. If a product is then selected
and combined, the user can view all of the relevant data,
including drawings and pictures. This means that you can
extensively plan how the enclosure will be integrated into
the customer‘s application.
The product assistant is available at
http://galaxy.weidmueller.com
V
V.9
Weidmüller Solutions & Service
Digital support
Online product catalogue
If you have questions about the specifications and details of
our products, even outside normal business hours, then our
online catalogue at
http://catalog.weidmueller.com
is opened 24 hours a day, 365 days a year and is the perfect
source for information. Besides product features and part
numbers, it contains extensive additional information on all
product groups.
For further information, offers and your personal contact,
simply consult the Weidmüller website at
www.weidmueller.com
With one click selection for the product data sheet of
your choice.
M-Print® PRO label designer
Our comprehensive range of Weidmüller services includes
the M-Print® PRO software. This is a professional standard,
Windows®-based program for printing and ordering labels
and markers that is coordinated with our current printing
systems and marking materials.
V
V.10
M-Print® PRO enables you to design your labelling materials
professionally and quickly. Texts, borders, lines, graphics,
barcodes, serial numbers and photographs are all possible.
The interface to RailDesigner® or your CAE system enables
the transfer of all your configured data.
1366860000 – 2013
Glossary/Technical appendix
Contents
Glossary/Technical appendix
Glossary/Technical appendix
Power Supplies – Overview
W.2
Standards and approvals
W.4
Glossary
W.6
W
1366860000 – 2013
W.1
Glossary/Technical appendix
Power Supplies – Overview
Power Supplies – Overview
Power supplies are important links in the energy supply
chain of automation systems. Unregulated power supplies
or regulated switched-mode power supplies are at the heart
of every electrical cabinet. 24 V DC has emerged as the
standard control voltage for the supply of electrical subassemblies and systems. But other control voltages are also
required. The correct power supply is a critical factor for the
reliable operation of the supplied components. Thus it must
be chosen with particular attention.
Power supplies from Weidmüller, whether regulated or
unregulated, have proven themselves reliable over many
years in the supply of electrical sub-assemblies and systems.
They perform reliably and safely – even under harsh
industrial conditions – in all sectors of machine construction,
industrial automation, and the power and process industries.
Weidmüller offers custom-fit solutions for practically all of
your requirements:
• Unregulated transformer power supplies
• Primary switch-mode power supplies
• DC/DC converters
• Diode modules
• UPS control modules
• Electronic fusing
How they work
Unregulated power supply units consist of a mains
power transformer that transforms the input voltage into a
different AC voltage. The units then make use of a rectifier
and a filter circuit to smooth out the DC output voltage.
Mains (AC)
Output
Unregulated transformer power supply
Regulated power supply units in the range up to
1,000 W are usually designed as primary switched-mode
power units. The mains AC voltage is then rectified and
transformed in high frequency to the secondary side using
switching transistors and power transformers. This is
followed by the rectifier and filter circuit in order to generate
the DC output voltage. A control circuit compares the
current and voltage on the output side to the specified target
values and then generates a control signal for the switching
transistors. This permits compensation for load changes and
mains voltage fluctuations. As a result, the output voltage
remains stable. These power supply units are increasingly
being operated with DC input voltages (for example,
Weidmüller‘s PRO-M line of switched-mode power supplies).
Controller
Mains (AC/DC)
Output
Switched-mode power supply
W
W.2
1366860000 – 2013
Glossary/Technical appendix
Power Supplies – Overview
A DC/DC converter is a variation of the classic switched
mode power supply. The switching strategy is similar but
there is no input rectifier. Starting with a specified DC input
voltage, DC/DC converters generate a different DC voltage
at a similar or different level. They are used to adapt different
voltage levels and also for isolating potentials.
Controller
Mains (DC)
Output
DC/DC converter
In use around the globe
Weidmüller‘s power supply units have been designed for
use around the world. They can be used in practically all
applications throughout the world because of their CE label
and many other national and international approvals. Their
wide input voltage ranges and compatibility with various
mains power connections increases their global appeal.
Temperature range
During operation, power supply units generate power
losses. In Weidmüller‘s switched-mode power supplies, the
resulting heat is dispersed using natural air currents only.
The design, which does not make use of a ventilation fan,
is an example of our uncompromised durability standard.
Weidmüller‘s power supply units, depending on the model,
can be used in temperatures ranging from -25 °C to +70 °C.
Compact and efficient design
Weidmüller‘s switched-mode power supplies are extra small
because they take advantage of the above-average degree
of efficiency offered by the latest technologies. The power
supplies from Weidmüller – whether they are book-shaped
with minimised base surface, or variants with reduced height
for use in distributor boxes – always provide the proper costsaving solution.
1366860000 – 2013
W
W.3
Glossary/Technical appendix
Standards and approvals
W
W.4
Standards and approvals
Standard/Approval
Description
DIN EN 50178
(VDE 0160)
Electronic equipment for use in power installations
DIN EN 60950-1
(VDE 0805-1)
IT Equipment – Safety –
Part 1: General requirements
DIN EN 61558-1
(VDE 0570-1)
Safety of transformers, power supply units, throttles and similar devices
Part 1: General requirements and tests
DIN EN 61558-2-17
(VDE 0570 Part 2-17)
Safety of transformers, power supply units and similar devices
Part 2-17: Special requirements for switch-mode power supply transformers
DIN EN 60204-1
(VDE 0113-1)
Safety of machinery – Electrical equipment of machinery –
Part 1: General requirements
DIN VDE 0100-410
Construction of power installations with rated voltages up to 1,000 V
Part 4: Protective measures
Chapter 41: Protection against electrical shock
DIN EN 61204-1
Power supply units for low voltages, with direct-current-output – properties
DIN EN 60947-1
Low-voltage switching devices – Part 1: General definitions
DIN EN 61140
Protection against electrical shock - common requirements for
facilities and operating equipment
IEC 38
Supplementary notes relating to status of international standards and European
harmonisation of mains voltages 230/400 V
73/23 EWG
Electrical equipment for use within specific voltage limits
(Low Voltage Directive)
2004/108/EG
(89/336 EWG)
Electromagnetic compatibility (EMC Directive)
2006/42/EG
(98/37 EG)
Safety of machines (directive covering mechanical equipment)
UL
Safety approval for the United States market
CSA
Safety approval for the Canadian market
GL
Test specifications for electrical/electronic devices and systems for use in marine technology
UL1310
Class 2 power supplies (limited energy)
UL1604
Electrical equipment for use in dangerous surroundings
1366860000 – 2013
Glossary/Technical appendix
Standards and approvals
Standard/Approval
Description
SEMI F47
Resistance of electronic devices against voltage drops
2006/95/EG
(72/23/EWG)
Low Voltage Directive
EN 60721-3-2
Classification of surrounding conditions
EN 60664-1
(VDE0110-1)
Insulation coordination for electrical equipment
C22.2 No. 107.1
General standards for power supplies (Canadian standard)
EN 61000-3-2
Limiting of mains voltage harmonic currents
EN 61000-4-x
Interference immunity tests
W
1366860000 – 2013
W.5
Glossary/Technical appendix
Glossary
Glossary
A
AC/DC converter
Conventional switched-mode power supplies generate a DC voltage from an
AC voltage. For this reason they are sometimes also called AC/DC converters.
Such devices are increasingly compatible for use with DC input voltages.
The primary and secondary sides are typically electrically isolated.
Ambient temperature (operational)
The ambient operating temperature (the min. and max. values) together with
the output current and voltage ratings can be used to describe the power
capabilities of a power supply unit.
B
Burst
A burst is a quick low-power burst pulse which can, for example, simulate
welding equipment phenomena. Similar phenomena can also result from
switching operations on the mains supply. This test can be used to demonstrate
immunity against quick transients.
C
W
W.6
Class of protection
Electrical equipment is classified according to varying classes of protection.
These classes define the particular safety measures that are required to avoid
an electrical shock. The most widely used power supplies correspond with
protection class I. The basic requirement of protection class I is for a basic
insulation and for the earthing of all conductive housing parts. If the basic
insulation fails, then the earthed conductive housing serves to prevent an
electrical shock. For this reason, devices in protection class I are equipped with
an earth (PE) connection.
Connecting power supply units
in parallel
Power supplies can only be connected in parallel when this is clearly permitted
by the manufacturer. Parallel connections are then normally tied to certain
conditions. This is a typical way to increase the output power (for example, when
extending a facility). Power supplies are also wired in parallel in order to design
redundant power supply systems. The parallel circuit is not wired straight though
but connects using decoupling diodes.
➝ Redundancy
Cooling
Cooling is used by components or devices to prevent them from overheating. A
variety of cooling strategies are available – two of the most common are natural
and forced-air cooling. Natural (convection-based) cooling takes advantage of the
natural air currents. Manufacturers must then ensure that there is sufficient air
flow by specifying the clearance gaps and mounting positions that are required
above and below the ventilation openings. Forced-air cooling normally uses a fan
to dissipate any heat that has been generated. When fans are used in a device,
they have the effect of increasing the likelihood of device outages. For this
reason, a power supply with natural cooling methods is generally preferred.
1366860000 – 2013
Glossary/Technical appendix
Glossary
D
DC/DC converter
DC/DC converters are switched-mode power supplies that convert a specific
DC voltage into another voltage. They are a variant of the AC/DC converter.
DC/DC converters, in their simplest implementation, do not isolate voltage
potentials. They are used only for adapting voltages. Improved DC/DC converters
have isolated voltages. A safety isolating transformer in the power element
ensures the required electrical isolation. Besides the voltage adaptation, the
isolation of the voltage potentials is an important factor.
Derating
For power supply devices, derating generally refers to the reduction in power as
influenced by the surrounding temperature and the input voltage. A temperature
derating often occurs starting at a surrounding temperature of 50 °C. The rated
power is guaranteed up to this temperature. The available power continually
declines as the temperature heats up above this level. This is typically specified
in %/K. A voltage-dependent specification is another form of derating For
switched-mode power supplies, the derating begins below a specific input
voltage. So a switched-mode power supply with a wide input range can typically
work under full power with 115 V AC input voltage. However at 85 V AC it can
only produce 60 % of the power rating. The coefficient is usually specified in
%/V.
Temperature derating
100
95
90
85
80
75
70
40
45
50
55
60
Temperature [°C]
Diode modules
65
Voltage derating
120
Max. current [%IN]
Max. current [%IN]
105
70
75
100
80
60
40
20
0
70
90
110 130 150 170 190 210 230 250 270
Main voltage [V]
Diode modules are used to construct a redundant power supply system. They
are important for decoupling the power supply unit. Thus, a short circuit that
occurs on the output of a power supply unit will not influence the output voltage.
E
Efficiency
The degree of efficiency is equal to the ratio of output power to input power and
is expressed in percent. The degree of efficiency can be between 70 and 90 %,
depending on the dimensions and type of technology in use.
EMC (electromagnetic compatibility) Electromagnetic compatibility describes the interference emissions caused by an
electronic device and the level of immunity against external electrical influences.
Interference emissions can be caused by cabling and wires or by radiated
emissions. Immunity measures the resistance against such wire-based emissions
and against radiated emissions such as electrostatic fields and magnetic fields.
Electric devices must also be protected against electrostatic discharges.
1366860000 – 2013
W
W.7
Glossary/Technical appendix
Glossary
F
Foldback characteristic curve
The foldback characteristic curve is a special type of output curve that protects
the power supply unit from overloads. When a specific current limit is exceeded
(for example, by 110 or 120 % of the nominal level), the current is limited
electronically and lowered to a very low, safe value. This downward-sloping
characteristic curve means that it is not sufficient to simply eliminate the
overload. The load must be reduced significantly more so that the adjustment
control can return to the normal voltage control. Thus this solution is not suitable
for many applications and is becoming less popular.
U
UA
INominal I Limit
I
G
Galvanic isolation
Galvanic (electrical) isolation ensures that no electrical connections can exist
between the primary and the secondary sides. Opto modules and transformers
are the typical components used.
H
Hiccup mode
The hiccup mode is a special output characteristic curve that protects power
supply units from overloads and short circuits. The unit switches off at a
specified current limit (for example, 110 or 120 % on the nominal rating) and
then switches back on after a certain delay. This leads to a pulsating mode of
operations which can only revert to continual operations after the overload has
been eliminated. The main disadvantage here is that the connected consumer
load must be restarted after every pause. A restart may not be possible with
motors or large capacitive loads since the restart current peak may once again
exceed the defined limit.
U
UA
W
t
I
ILimit
INominal
t
W.8
1366860000 – 2013
Glossary/Technical appendix
Glossary
Hold-up time
(mains-failure bridging time)
The hold-up time (also known as the mains-failure bridging time) is the interval
from the start of the mains outage to the point in time when the output voltage
can no longer be maintained at its original level. The hold-up time indicates how
long a mains outage may last before it influences the output voltage. For DC
power supplies, EN 61204 requires a bridging time of at least 20 ms.
U
UA
hold-up time
Power failure
(cutoff)
t
I
Input voltage range
This refers to the minimum and maximum input voltage at which the rated
output specifications can be maintained.
Inrush current
The inrush current refers to the peak current that occurs when turning on a
consumer load. Switched-mode power supplies have storage capacitors in the
input which can cause significant current peaks while the mains power is being
switched on. A variety of circuitry solutions can be used to attenuate these
current peaks. In the simplest solution, an inrush limiter is used. Active switching
can be used in other cases. The peak current specification indicates which
upstream fuse should be used in the circuit. If a fuse is selected which is too
sensitive, it can trigger when the mains power is switched on.
W
1366860000 – 2013
W.9
Glossary/Technical appendix
Glossary
IU characteristic curve
The IU characteristic curve is a special output characteristic curve that
protects power supply units from overloads and short circuits. It offers the best
performance with regards to overload and short circuit capabilities. A current
limit is activated at a specific current level (for example, 110 or 120 % on the
nominal rating). As the load continues to increase, the output voltage is reduced
according to the current limit curve until it reaches a level approaching zero
volts. Thus a pulsating mode of operations is avoided for short-term overloads.
Large capacitive loads or motors are brought back up along the slope of the
current-limit characteristic curve. After a short circuit or overload is fixed, the IU
characteristic curve offers the advantage of immediately returning to the normal
voltage control mechanism. The full output voltage is then immediately available.
The IU characteristic curve is becoming the established standard for modern
power supplies. Additional variants are available which pertain to the peak
current capacity and the slope of the current-limit characteristic curve.
U
UA
INominal I Limit
I
M
Mains harmonics
Power supplies can experience harmonics caused by mains rectification on the
input side. These harmonics are multiples of the mains frequencies. Existing
standards define specific limit values since such harmonics can significantly
lower the mains quality.
Mains system types
This refers to the types of mains supply systems. Systems differ in their method
of earthing and the implementation of the phase wire, PE wire and central-point
wire. Common mains systems include the TN, IT and TT networks. The individual
mains types can also differ in their voltage levels and frequencies.
PRO-M
PRO-M
L N PE
TN-S Mains
L1
L2
L3
N
PE
W
W.10
MTBF (mean time between failure)
PRO-M
L N PE
TN-C Mains
L1
L2
L3
PEN
PRO-M
L N PE
TT Mains
L1
L2
L3
N
L N PE
IT Mains
L1
L2
L3
N
The MTBF is a statistical value that specifies the probability that a product will
fail. It is typically specified in hours and normally assumes a temperature of
25 °C. The probability of failure depends largely on the ambient surroundings.
The key variables are the type of load and the ambient temperature.
1366860000 – 2013
Glossary/Technical appendix
Glossary
O
Output characteristic curves
The output characteristic curves of power supply devices are determined by
current and voltage. Unregulated devices do not have a current limit. In the
case of an overload or short circuit, fuses or temperature switches are used to
protect the device. Regulated devices are protected against overload and short
circuits by means of various output characteristic curves. In this case, the system
attempts to prevent any activation of fuses or temperature switches.
The mandatory manual reset which follows an overload or short circuit can then
be avoided. Common output characteristic curves include the hiccup mode, the
foldback characteristic curve or the IU characteristic curve.
➝ Hiccup mode, foldback characteristic curve, IU characteristic curve
Overvoltage category
Power supply units are classified into overvoltage categories according to the
immunity against mains surges and transient voltages.
P
PELV (protective extra-low voltage)
This is a functional DC voltage with secure isolation according to EN 50178. As
with SELV, a reinforced or double insulation is used between the primary and
secondary sides. However, the secondary side is earthed.
PFC (power factor correction)
The power factor correction can be either passive or active in relation to power
supply devices. The reactive power resulting from the bridge rectification puts
a significant strain on the power supply network. The relatively poor power
efficiency factor that results can be improved by using passive components
(such as filters) or an active electronic mechanism. For switched-mode power
supplies, PFC usually refers to the active variant of the power factor correction.
Power factors of almost 1 can be reached when using an active PFC. Practically
no reactive power is drawn from the mains supply network; therefore the strain
on the mains network is relatively low.
Pollution severity
Pollution severity describes the environment and ambient conditions that a
device requires in order for it to function smoothly. Significant environmental
variables include condensation or air containing dust and oil.
Power-boost or boost
The power-boost function is the surge current handling capacity in the seconds
to minutes range. This function is often required for starting up DC motors. DC
motors have a high start-up current and often require several seconds before
they have achieved their rated rotational speed. The power-boost function helps
to optimise this start-up phase.
Power factor
The power factor is the ratio of reactive power to apparent power. It is an
indicator of the device performance with respect to the load on the mains power
network. Depending on the technology in use, the power factor for power
supplies can be between 0.45 and nearly 1.
1366860000 – 2013
W
W.11
Glossary/Technical appendix
Glossary
Power loss
For power supply units, the power loss specification indicates the thermal
output emitted during nominal (rated) operations. This is a key specification
used by engineers when designing the climate control systems within electrical
cabinets. It is calculated as the difference between the input and output power
and can also take the degree of efficiency into account.
Power rating
The continual output permitted under the rated conditions.
Power supply units connected in
series
Power supplies can only be connected in series when this is clearly permitted
by the manufacturer. Such series connections are then normally tied to certain
conditions. They can be used to increase the output voltage. This is not widely
implemented.
Protection degree
According to DIN EN 60529, devices can be classified according to their
protection degrees. The numeric code (for example, IP 20) defines two
protection degrees: protection against touch or penetration by external objects
(the first digit) and protection against water penetration (the second digit).
Switched-mode power supplies intended for use in electrical cabinets or similar
enclosures are often designed with IP 20 protection. The first digit (in this case,
2) ensures finger protection. The second digit (0) indicates that no protection
against water is provided.
Pulsed current capacity
The pulsed current capacity describes the dynamic performance of a switchedmode power supply. Capacitive consumer loads, with their high inrush currents,
put a particular strain on a switched-mode power supply. Peak values are
reached (in the ms range) which amount to levels many times higher than the
mains current. If the current control mechanism reacts too quickly, this can
lead to voltage drops and can cause problems for loads which are connected in
parallel. For this reason, power supplies are often equipped with a surge current
limiting factor based on time. This allows a high current output for only a few ms
which can be much higher than the rated current.
R
W
W.12
Rated control voltage
The nominal value of the sparkover voltage for the relay.
Rated input voltage
The input voltage required at which, under the normal mains voltage
fluctuations, the output levels can be kept stable. It usually corresponds to the
rated voltage for the electric utility‘s power grid.
Rated output current
The long-term current permitted under the rated conditions.
Rated output voltage
The nominal output voltage used for the rated specifications. It usually
corresponds to the factory default output voltage.
1366860000 – 2013
Glossary/Technical appendix
Glossary
Redundancy
A power supply system is considered redundant if it is constructed so that it has
partial power supplies which are independent of each other and each of these
can individually deliver the output load. When a fault occurs, therefore, it is still
possible to continue to supply the connected rated load. In reality, at least two
power supplies are connected in parallel using decoupling diodes. In this way, a
short circuit in the output of one power supply will not lead to the failure of the
entire power supply system.
➝ Diode modules
Regulated power supply units
Switched-mode power supplies, as opposed to more common power supply
units, have become established as the standard for the 10–1,000 W power
range. They produce a stable output voltage with minimal residual ripple, even
when influenced by fluctuations in the mains voltage, mains frequency or load.
Their small size and weight is a result of their superior efficiency degree. The
electronic control mechanism typically ensures a constant output voltage that
varies ±1 %.
Residual ripple
The residual ripple describes the ratio of superimposed AC voltage to DC voltage
on the output side of the power supplies. In addition to a percent specification,
the superimposed ripple is often specified in mVSS for switched-mode power
supplies.
Resistance to shock
Resistance to shock refers to mechanical immunity against impacts in any
direction. This is a key factor while the product is being transported.
Response time
The response time is the time that a power supply unit needs to compensate for
a disturbance (for example, a load fluctuation).
S
Switching frequency
Switched-mode power supplies are normally operated with switching
frequencies from 20 to 200 kHz. The HF or power transformer is switched on
an off using transistors at this switching frequency. Small, compact units can be
built with this method in comparison with the traditional 50/60 Hz transformers.
W
1366860000 – 2013
W.13
Glossary/Technical appendix
Glossary
Switched-mode power supply units
The switching pulse can be either primary or secondary. Thus there are primary
switched-mode and secondary switched-mode power supply units. Secondary
switched-mode power supply units are no longer of much significance. The
primary switched-mode power supplies are now the focus of attention. The
pulse refers to the high-frequency on and off switching of the transformer or
transmitter in order to transmit energy. The high frequency allows the use of
extra small inductive and capacitive components, particularly for the transmitter.
In comparison to transformer-based power supply units, the weight and volume
required are much reduced.
L
+
–
N
PE
Selectivity
When surge protection equipment is connected in series, selectivity refers to the
ability of only one upstream fuse to trigger selectively in the event of an overload.
The differentiation can take into account current or also time. With DC power
supply systems, selectivity refers to the separate fusing of load circuits on the DC
side. In this case as well, only the proper series fuse should trigger in the event
of an overload. Fuses in DC circuits play a critical role since the power supplies
must react to upcoming short circuits with a speedy cut-off or by limiting the
current. Usually electronic fuses are used for this purpose.
Mains
Mains
63 A
25 A
˜
= Power Supplies
16 A
Load
Selectivity for fuses
connected in series
W
W.14
Load Load Load
Selectivity for DC systems
SELV (safety extra low voltage)
SELV refers to extra-low safety voltages according to IEC/EN 60950. Reinforced
or doubled insulation between the primary and secondary sides is used to
prevent electric shock. The output voltage here is sufficiently low so that it does
not pose an injury risk if a person comes into direct contact. Earthing on the
secondary side is possible but not required.
Surge
A surge is a high-power voltage pulse which can be caused by, for example, a
lightning strike. The switching operations from large consumer loads can also
generate such voltage surges on the mains network. The surge test is used to
demonstrate the immunity against high-power voltage pulses.
1366860000 – 2013
Glossary/Technical appendix
Glossary
T
Temperature range
The temperature range specifies the minimum and maximum ambient
temperatures for which a device can start up and run continuously.
U
Unregulated power supply units
Unregulated power supplies consist mainly of a transformer, a rectifier and an
Elkos filter. Since no controlling system is in place, mains voltage fluctuations
influence the DC voltage side. Unregulated power supply units are very sturdy;
they can be used in applications where a stabilised DC voltage is not necessary
(for example, power supply to contactors).
V
Vibration resistance
Vibration resistance describes the resistance against constant mechanical
vibrations that occur during operations. Rail and ship applications place stricter
demands for vibration resistance on the device.
W
Wide-range input
Modern switched-mode power supplies often feature a wide input range. They
can be run under a wide range of voltages: from min. to max. rated voltages
including the tolerance limits. They do not require any manual range switching.
Status: 01.07.2012
W
1366860000 – 2013
W.15
W
W.16
1366860000 – 2013
Glossary/Technical appendix
Contents
Index
Index
Index
Index Type
X.2
Index Order No.
X.3
Addresses worldwide
X.4
X
1366860000 – 2013
X.1
Type
B
BG GH 10P 4XVG PT6
BG GHDE 10P HO PT6
BG GHDE 10P PT6
BG SNT PT6
Index / Type
C
CP A BATTERY 24V DC12AH
CP A BATTERY 24V DC17AH
CP A BATTERY 24V DC3.4AH
CP A BATTERY 24V DC7.2AH
CP DC BUFFER 24V 20A
CP DC UPS 24V 20A/10A
CP DC UPS 24V 40A
CP DCDC 250W 24V 10A
CP DCDC 50W 12V 3A
CP DCDC 50W 12V 3A
CP DCDC 50W 15V 3A
CP DCDC 50W 15V 3A
CP DCDC 50W 22-24V 2A
CP DCDC 50W 22-24V 2A
CP DCDC 50W 5V 8A
CP DM 10
CP DM 20
CP M CAP
CP M CAP
CP M DM20
CP M DM20
CP M DM40
CP M DM40
CP M RM24
CP M SNT 1000W 24V 40A
CP M SNT 1000W 24V 40A
CP M SNT 120W 24V 5A
CP M SNT 120W 24V 5A
CP M SNT 180W 24V 7,5A
CP M SNT 180W 24V 7,5A
CP M SNT 250W 24V 10A
CP M SNT 250W 24V 10A
CP M SNT 250W 24V 10AUW
CP M SNT 500W 24V 20A
CP M SNT 500W 24V 20A
CP M SNT 70W 24V 3A
CP M SNT 70W 24V 3A
CP M SNT3 1000W 24V 40A
CP M SNT3 1000W 24V 40A
CP M SNT3 120W 24V 5A
CP M SNT3 120W 24V 5A
CP M SNT3 250W 24V 10A
CP M SNT3 250W 24V 10A
CP M SNT3 500W 24V 20A
CP M SNT3 500W 24V 20A
CP NT 144W 24V 6A
CP NT 192W 24V 8A
CP NT 264W 24V 11A
CP NT 36W 24V 1.5A
CP NT 432W 24V 18A
CP NT 72W 24V 3A
CP NT3 1000W 24V 40A
CP NT3 250W 24V 10A
CP NT3 400W 24V 15A
CP NT3 500W 24V 20A
CP NT3 600W 24V 25A
CP NT3 750W 24V 30A
CP SNT 1000W 24V 40A
CP SNT 120W 24V 5A
CP SNT 12W 24V 0.5A
CP SNT 160W 12-15V 8A
CP SNT 160W 24-28V 6.5A
CP SNT 160W 48V 3.5A
CP SNT 160W 5V 8A
CP SNT 24W 12V 1.5A
CP SNT 24W 15V 1.5A
CP SNT 24W 24V 1A
CP SNT 24W 28V 1A
CP SNT 24W 5V 2A
CP SNT 250W 24V 10A
CP SNT 25W 5V 5A
CP SNT 300W 24V 12.5A
CP SNT 48W 12V 4A
CP SNT 48W 24V 2A
CP SNT 48W 48V 1A
CP SNT 500W 24V 20A
CP SNT 55W 12-15V 3A
CP SNT 55W 24-28V 2.3A
CP SNT 55W 48V 1.04A
CP SNT 55W 5V 3A
CP SNT 70W 24V 3A
CP SNT3 1000W 24V 40A
CP SNT3 120W 24V 5A
CP SNT3 250W 24V 10A
CP SNT3 500W 24V 20A
CP T RM 10
CP T RM 20
CP T SNT 140W 12V 12A
CP T SNT 180W 24V 7,5A
CP T SNT 180W 48V 4A
X
X.2
Order No.
Page
1121990000
1121950000
1122200000
1101940000
E.10
E.11
E.11
E.7
1251090000
1251110000
1251070000
1251080000
1251220000
1370050010
1370040010
1313320010
9919371212
9919372412
9919371215
9919372415
9919371224
9919372424
9919372405
8710620000
8768650000
1222240000
1222240010
1222210000
1222210010
1222220000
1222220010
1222230000
8951380000
8951380010
8951340000
8951340010
8951350000
8951350010
8951360000
8951360010
1165480010
8951370000
8951370010
8951330000
8951330010
8951420000
8951420010
8951390000
8951390010
8951400000
8951400010
8951410000
8951410010
8575280000
8575300000
8575310000
8575260000
8575320000
8575270000
8628680000
8628620000
8628630000
8628650000
8628660000
8628670000
8862780000
8708670000
9918840024
9925340012
9925340024
9925340048
9925340005
9928890012
9928890015
9928890024
9928890028
9928890005
8708680000
8754960000
9916250024
8754970000
8739140000
8879230000
8778870000
9927480012
9927480024
9927480048
9927480005
8708660000
8708730000
8862730000
8708700000
8708710000
1105880000
1105890000
1105440000
1105810000
1105850000
B.7
B.7
B.6
B.6
B.8
B.5
B.5
A.57
A.53
A.54
A.53
A.52
A.53
A.52
A.54
A.37
A.37
A.12
A.12
A.10
A.10
A.10
A.10
A.11
A.7
A.7
A.5
A.5
A.6
A.6
A.6
A.6
A.15
A.7
A.7
A.5
A.5
A.9
A.9
A.8
A.8
A.8
A.8
A.9
A.9
D.5
D.5
D.6
D.4
D.6
D.4
D.9
D.7
D.7
D.8
D.8
D.9
A.32
A.29
A.45
A.49
A.48
A.48
A.49
A.39
A.39
A.38
A.38
A.40
A.30
A.41
A.50
A.42
A.43
A.44
A.31
A.47
A.46
A.46
A.47
A.28
A.36
A.33
A.34
A.35
A.25
A.25
A.17
A.19
A.21
Type
CP T SNT 360W 24V 15A
CP T SNT 360W 48V 7,5A
CP T SNT 600W 24V 25A
CP T SNT 600W 36V 16,5A
CP T SNT 600W 48V 12,5A
CP T SNT 70W 12V 6A
CP T SNT 90W 24V 3,8A
CP T SNT 90W 24V3,8ACL2
CP T SNT 90W 48V 2A
CP T SNT2 180 W 24 V 7,5 A
CP T SNT2 360 W 24 V 15 A
CP T SNT2 600 W 24 V 25 A
CP-SNT 380-480VAC/24V
D
DG D0 PT6
F
FP Box 10P SNT
FP Box 10P SNT 4XVG
G
GH 10P PT6
P
PT6
PT6 230/BUS
PT6 DC
PTDS 4
PTDS 4 DC
PTS 4
PTS 4 DC
PTS 4 MPB
PTSI 4/LD 36V AC/DC
PTSI 4/LD 400V AC
R
RKDG D11 PT6
RKDG D13 PT6
RKDG D15 PT6
RKDG D17 PT6
RKDG D9 PT6
S
Schuko TS35
T
TS 35 PT6
W
WGS 24Vdc 0.5...5A
WGS 24Vdc 1,6A
WGS 24Vdc 3,15A
WGS 24Vdc 6,3A
WGS 24Vdc 8,0A
WGZ 24Vdc 0.5...5A
WGZ 24Vdc 1,6A
WGZ 24Vdc 3,15A
WGZ 24Vdc 6,3A
WGZ 24VDC 8,0A
Order No.
Page
1105820000
1105860000
1105840000
1194430000
1105870000
1105430000
1105790000
1194410000
1194420000
1194480000
1194490000
1194310000
9917790324
A.19
A.22
A.20
A.20
A.22
A.17
A.18
A.18
A.21
A.23
A.23
A.24
A.51
4323240000
E.12
1132320000
1076510000
E.6
E.6
1121980000
E.10
1957620000E.14
1269960000
E.15
1126840000
E.14
1952130000
E.16
1009990000
E.17
1952120000
E.16
1131730000
E.17
1010910000
E.18
1252210000
E.19
1961770000
E.19
4323210000
4323230000
4323220000
4324010000
4329610000
E.12
E.12
E.12
E.12
E.12
8734580000
E.24
1170690000
E.10
8710270000
8618890000
8618910000
8618930000
8618940000
8727630000
8621040000
8621030000
8621020000
8621010000
C.6
C.4
C.4
C.5
C.5
C.6
C.4
C.4
C.5
C.5
1366860000 – 2013
Type
1000000000
1009990000 PTDS 4 DC
1010000000
1010910000
PTS 4 MPB
1070000000
1076510000 FP Box 10P SNT 4XVG
1100000000
1101940000
1105430000
1105440000
1105790000
1105810000
1105820000
1105840000
1105850000
1105860000
1105870000
1105880000
1105890000
BG SNT PT6
CP T SNT 70W 12V 6A
CP T SNT 140W 12V 12A
CP T SNT 90W 24V 3,8A
CP T SNT 180W 24V 7,5A
CP T SNT 360W 24V 15A
CP T SNT 600W 24V 25A
CP T SNT 180W 48V 4A
CP T SNT 360W 48V 7,5A
CP T SNT 600W 48V 12,5A
CP T RM 10
CP T RM 20
1120000000
1121950000
1121980000
1121990000
1122200000
1126840000
BG GHDE 10P HO PT6
GH 10P PT6
BG GH 10P 4XVG PT6
BG GHDE 10P PT6
PT6 DC
1130000000
1131730000 PTS 4 DC
1132320000 FP Box 10P SNT
1160000000
1165480010 CP M SNT 250W 24V 10AUW
1170000000
1170690000 TS 35 PT6
1190000000
1194310000
1194410000
1194420000
1194430000
1194480000
1194490000
CP T SNT2 600 W 24 V 25 A
CP T SNT 90W 24V3,8ACL2
CP T SNT 90W 48V 2A
CP T SNT 600W 36V 16,5A
CP T SNT2 180 W 24 V 7,5 A
CP T SNT2 360 W 24 V 15 A
1220000000
1222210000
1222210010
1222220000
1222220010
1222230000
1222240000
1222240010
CP M DM20
CP M DM20
CP M DM40
CP M DM40
CP M RM24
CP M CAP
CP M CAP
1250000000
1251070000
1251080000
1251090000
1251110000
1251220000
1252210000
CP A BATTERY 24V DC3.4AH
CP A BATTERY 24V DC7.2AH
CP A BATTERY 24V DC12AH
CP A BATTERY 24V DC17AH
CP DC BUFFER 24V 20A
PTSI 4/LD 36V AC/DC
1260000000
1269960000 PT6 230/BUS
1310000000
1313320010 CP DCDC 250W 24V 10A
1370000000
1370040010 CP DC UPS 24V 40A
1370050010 CP DC UPS 24V 20A/10A
1950000000
1952120000 PTS 4
1952130000 PTDS 4
1957620000PT6
1960000000
1961770000 PTSI 4/LD 400V AC
1366860000 – 2013
Page
E.17
E.18
E.6
E.7
A.17
A.17
A.18
A.19
A.19
A.20
A.21
A.22
A.22
A.25
A.25
E.11
E.10
E.10
E.11
E.14
E.17
E.6
A.15
E.10
A.24
A.18
A.21
A.20
A.23
A.23
A.10
A.10
A.10
A.10
A.11
A.12
A.12
B.6
B.6
B.7
B.7
B.8
E.19
E.15
A.57
B.5
B.5
E.16
E.16
E.14
E.19
Order No.
Type
4320000000
4323210000
4323220000
4323230000
4323240000
4324010000
4329610000
RKDG D11 PT6
RKDG D15 PT6
RKDG D13 PT6
DG D0 PT6
RKDG D17 PT6
RKDG D9 PT6
8570000000
8575260000
8575270000
8575280000
8575300000
8575310000
8575320000
CP NT 36W 24V 1.5A
CP NT 72W 24V 3A
CP NT 144W 24V 6A
CP NT 192W 24V 8A
CP NT 264W 24V 11A
CP NT 432W 24V 18A
8610000000
8618890000
8618910000
8618930000
8618940000
WGS 24Vdc 1,6A
WGS 24Vdc 3,15A
WGS 24Vdc 6,3A
WGS 24Vdc 8,0A
8620000000
8621010000
8621020000
8621030000
8621040000
8628620000
8628630000
8628650000
8628660000
8628670000
8628680000
WGZ 24VDC 8,0A
WGZ 24Vdc 6,3A
WGZ 24Vdc 3,15A
WGZ 24Vdc 1,6A
CP NT3 250W 24V 10A
CP NT3 400W 24V 15A
CP NT3 500W 24V 20A
CP NT3 600W 24V 25A
CP NT3 750W 24V 30A
CP NT3 1000W 24V 40A
8700000000
8708660000
8708670000
8708680000
8708700000
8708710000
8708730000
CP SNT 70W 24V 3A
CP SNT 120W 24V 5A
CP SNT 250W 24V 10A
CP SNT3 250W 24V 10A
CP SNT3 500W 24V 20A
CP SNT3 1000W 24V 40A
8710000000
8710270000 WGS 24Vdc 0.5...5A
8710620000 CP DM 10
8720000000
8727630000 WGZ 24Vdc 0.5...5A
8730000000
8734580000 Schuko TS35
8739140000 CP SNT 48W 24V 2A
8750000000
8754960000 CP SNT 25W 5V 5A
8754970000 CP SNT 48W 12V 4A
8760000000
8768650000 CP DM 20
8770000000
8778870000 CP SNT 500W 24V 20A
8860000000
8862730000 CP SNT3 120W 24V 5A
8862780000 CP SNT 1000W 24V 40A
8870000000
8879230000 CP SNT 48W 48V 1A
8950000000
8951330000
8951330010
8951340000
8951340010
8951350000
8951350010
8951360000
8951360010
8951370000
8951370010
8951380000
8951380010
8951390000
8951390010
CP M SNT 70W 24V 3A
CP M SNT 70W 24V 3A
CP M SNT 120W 24V 5A
CP M SNT 120W 24V 5A
CP M SNT 180W 24V 7,5A
CP M SNT 180W 24V 7,5A
CP M SNT 250W 24V 10A
CP M SNT 250W 24V 10A
CP M SNT 500W 24V 20A
CP M SNT 500W 24V 20A
CP M SNT 1000W 24V 40A
CP M SNT 1000W 24V 40A
CP M SNT3 120W 24V 5A
CP M SNT3 120W 24V 5A
Page
E.12
E.12
E.12
E.12
E.12
E.12
D.4
D.4
D.5
D.5
D.6
D.6
C.4
C.4
C.5
C.5
C.5
C.5
C.4
C.4
D.7
D.7
D.8
D.8
D.9
D.9
Order No.
8951400000
8951400010
8951410000
8951410010
8951420000
8951420010
Type
CP M SNT3 250W 24V 10A
CP M SNT3 250W 24V 10A
CP M SNT3 500W 24V 20A
CP M SNT3 500W 24V 20A
CP M SNT3 1000W 24V 40A
CP M SNT3 1000W 24V 40A
9910000000
9916250024
9917790324
9918840024
9919371212
9919371215
9919371224
9919372405
9919372412
9919372415
9919372424
CP SNT 300W 24V 12.5A
CP-SNT 380-480VAC/24V
CP SNT 12W 24V 0.5A
CP DCDC 50W 12V 3A
CP DCDC 50W 15V 3A
CP DCDC 50W 22-24V 2A
CP DCDC 50W 5V 8A
CP DCDC 50W 12V 3A
CP DCDC 50W 15V 3A
CP DCDC 50W 22-24V 2A
9920000000
9925340005
9925340012
9925340024
9925340048
9927480005
9927480012
9927480024
9927480048
9928890005
9928890012
9928890015
9928890024
9928890028
CP SNT 160W 5V 8A
CP SNT 160W 12-15V 8A
CP SNT 160W 24-28V 6.5A
CP SNT 160W 48V 3.5A
CP SNT 55W 5V 3A
CP SNT 55W 12-15V 3A
CP SNT 55W 24-28V 2.3A
CP SNT 55W 48V 1.04A
CP SNT 24W 5V 2A
CP SNT 24W 12V 1.5A
CP SNT 24W 15V 1.5A
CP SNT 24W 24V 1A
CP SNT 24W 28V 1A
Page
A.8
A.8
A.9
A.9
A.9
A.9
Index / Order No.
Order No.
A.50
A.51
A.45
A.53
A.53
A.53
A.54
A.54
A.52
A.52
A.49
A.49
A.48
A.48
A.47
A.47
A.46
A.46
A.40
A.39
A.39
A.38
A.38
A.28
A.29
A.30
A.34
A.35
A.36
C.6
A.37
C.6
E.24
A.43
A.41
A.42
A.37
A.31
A.33
A.32
A.44
A.5
A.5
A.5
A.5
A.6
A.6
A.6
A.6
A.7
A.7
A.7
A.7
A.8
A.8
X
X.3
Addresses worldwide
Addresses worldwide
AE
United
Arab Emirates
Weidmuller Middle East FZE
P.O. Box 8591, SAIF-Zone
Sharjah U. A. E.
Phone +971 6 5572723
Fax +971 6 5572724
[email protected]
AR
Argentina
CPI SA
Bauness 2660
1431 Buenos Aires
Phone +54 11 45238008
Fax +54 11 45220546
[email protected]
www.cpi.com.ar
AT
AU
AZ
BA
BY
Belarus
Technikon Ltd.
Nezavisimosti pr.177-9
Minsk 220125
Phone +375 17 3931177
Fax +375 17 3930080
[email protected]
CA
Canada
W Interconnections CANADA
Ltd.
10 Spy Court, Markham,
Ontario L3 R5 H6
Phone +1 905 475-1507
Fax +1 905 475-2798
[email protected]
www.weidmuller.ca
Austria
Weidmüller GmbH Austria
Straße 2, Industriezentrum Nö
Süd Straße 2b M59
2355 Wiener Neudorf
Phone +43 2236 6708-0
Fax +43 2236 6708-199
[email protected]
CH
Australia
Weidmüller Pty. Ltd.
P.O.Box 6944
Huntingwood Drive 43
Huntingwood,
NSW, 2148
Phone +61 2 9671-9999
Fax +61 2 9671-9911
[email protected]
www.weidmuller.com.au
CL
Azerbaijan
West Industries Ltd.
Caspian Plaza, 5-th Floor
44 J. Jabbarly Str., Baku
Phone +99412 596 15 15
Fax +99412 596 14 93
[email protected]
Bosnia and Herzegovina
Representative Office
Weidmüller Interface
GmbH & Co. KG
Beograd-Stari Grad
Danice Marković 2
11050 Beograd
Srbija
Phone +381 11 288 5274
Fax +381 11 288 5274
zoran.rabrenovic@
weidmueller.com
CO
BH ES ELEKTROSISTEM d.o.o.
Bul. Vojvode S.
Stepanovica kod br. 272
78000 BiH - Banja Luka
Phone +387 51 420-340
Fax +387 51 420-341
[email protected]
www.elektrosistem.ba
BE
Belgium
Weidmüller Benelux B.V.
Mechelsesteenweg 519 bus
6 en 7
1930 Nossegem
Phone +32 2 752 4070
Fax +32 2 751 3606
[email protected]
www.weidmueller.be
CR
Bulgaria
Weid-Bul EOOD
1756 Sofia
13, bul. "Kliment Ohridski"
Phone +359 2 9632560
Fax +359 2 9631098
[email protected]
www.weidbul.com
CZ
BH
Bahrain
Khayber Trading Company
P.O. Box 1976 Manama,
Phone +973 720747
Fax +973 720331
[email protected]
DE
BR
Brazil
Weidmüller Conexel do Brasil
Conexões Elétricas Ltda.
Rua Garcia Lorca, 176
09695-900, Sao Paulo SP
Phone +55 11 43669600
Fax +55 11 43621677
[email protected]
www.weidmueller.com.br
BG
X
X.4
X.2
DK
Ecuador
Elsystec S. A. Electricidad
Sistemas y Tecnología
Vasco de Contreras N35-25
y Mañosca, Quito
Phone +593 2 2456510
Fax +593 2 2456755
[email protected]
EE
Estonia
Representative Office
Weidmüller Interface
GmbH & Co. KG
Udens str. 12-118
Riga, LV-1007
Latvia
Phone +371 29254766
Fax +371 67624562
ilgonis.rudaks@
weidmueller.com
Switzerland
Weidmüller Schweiz AG
Rundbuckstraße 2
8212 Neuhausen am Rheinfall
Phone +41 52 6740707
Fax +41 52 6740708
[email protected]
www.weidmueller.ch
Chile
Felipe Bahamondes S.A./
ATS AGRO
Maria Luisa Santander 0475
Casilla 3425
Santiago
Phone +56 2 341-1271
Fax +56 2 341-1275
[email protected]
CPI CHILE LTDA
Av. Presidente Frei Montalva
6001-47, Conchali Region Metropolitana Santiago
[email protected]
CN
EC
China
Weidmüller Interface
International Trading
(Shanghai) Co., Ltd.
25F, BM Intercontinental
Business Center,
100 Yutong Road,Shanghai
200070
P.R. China
Phone +86 21 22195008
Fax +86 21 22195009
www.cnweidmuller.com
Colombia
Automatización Avanzada S. A.
Carrera 97 No.24c, 23 B4
4 Bogotá D. C.
Phone +57 1 5478510
Fax +57 1 4223044
comercial@
automatizacionavanzada.com
www.
automatizacionavanzada.com
Soots Interface OÜ
Pärnu mnt 142
11317 Tallinn
Phone +372 5296177
Fax +372 6096933
[email protected]
www.sootsinterface.ee
EG
ES
Fl
FR
GB
Costa Rica
ELVATRON S.A.
la Uruca 400 Norte
Banco Costa Rica
San José Costa Rica
Phone +506 2 961060
Fax +506 5 200609
[email protected]
www.elvatron.com
Czech Republic
Weidmüller s. r. o.
Lomnického 5/1705
14000 Praha 4
Phone +420 2 44001400
Fax +420 2 44001499
[email protected]
www.weidmueller.cz
Germany
Weidmüller GmbH & Co. KG
Postfach 3054
32720 Detmold
Ohmstraße 9
32758 Detmold
Phone +49 5231 1428-0
Fax +49 5231 1428-116
[email protected]
www.weidmueller.de
Denmark
Wexøe A/S
Lejrvej 31
3500 Vaerloese
Phone +45 45465800
Fax +45 45465801
[email protected]
www.wexoe.dk
GR
HR
Hungary
Weidmüller Kft
Gubacsi út 6
1097 Budapest
Phone +36 1 3827700
Fax +36 1 3827701
[email protected]
ID
Indonesia
PT. Nego Electrindo
Ruko Mega Grosir Cempaka
Mas, Blok I No 20 – 22
Jl. Let.Jend. Suprato –
Jakarta 10640
Phone +62 21 42882255
Fax +62 21 42882266
[email protected]
IE
Ireland
Please contact
Weidmüller Ltd.
in Great Britain
IL
Israel
A.U.Shay Ltd.
P.O. Box 10049
Embar Street 23/25
49222 Petach-Tikva
Phone +972 3 9233601
Fax +972 3 9234601
Egypt
Standard Electric (OMEGA)
87, Mohamed Farid Street
Heliopolis, Cairo
Phone +20 26422977
Fax +20 26422955
[email protected]
Spain
Weidmüller S. A.
Narcis Monturiol 11-13
Pol. Ind. Sudoeste
08960 Sant Just Desvern
Barcelona
Phone +34 93 4803386
Fax +34 93 3718055
[email protected]
www.weidmuller.es
Finland
JUHA-ELEKTRO OY
P. O. Box 57, 641 Helsinki
Kylvöpolku 6, 680 Helsinki
Phone +358 10 8328 100
Fax +358 10 8328 109
[email protected]
www.juha-elektro.fi
France
Weidmüller E. U. R. L.
12, Chaussée Jules César
B.P. 263 Osny
95523 Cergy Pontoise Cedex
Phone +33 1 34245500
Fax +33 1 34245501
[email protected]
Great Britain
Weidmüller Ltd
Klippon House
Centurion Court Office
Meridian East, Meridian
Business Park
Leicester, LE19 1TP
Phone +44 1162 823470
Fax +44 1162 893582
[email protected]
www.weidmuller.co.uk
Greece
Electrorama S.A.
1 An. Martali Str.
41335 Larissa
Phone +30 2410 552533188
Fax +30 2410 283463189
[email protected]
GA Contact Solutions
11, Ippokratous Str.
14452 Metamorfosi Attika
Phone +30 210 2823233
Fax +30 210 2823233
[email protected]
HK
HU
Hong Kong
Weidmuller (Hong Kong)
Limited
Unit 1617, The Metropolis
Tower, No.10, Metropolis
Drive, Hunghom, Kowloon
Phone +852 31548082
Fax +852 31548099
[email protected]
Hong Kong
ATEKA Ltd.
4, Ha‘Tavor lane
Industrial area Segula
49691 Petach-Tikva
Phone +972 73 2001311
Fax +972 3 9244245
[email protected]
www.ateka.co.il
IN
IS
IT
India
Weidmuller
Electronics India Pvt. Ltd
Plot # 32, 3rd Floor,
North Court
Lane North Avenue,
Opp Jogger's Park
Kalyani Nagar, Maharastra
411006 Pune
Phone +91 9049800960
[email protected]
Italy
Weidmüller S.R.L.
Via Albert Einstein 4
20092 Cinisello Balsamo
Milano
Phone +39 02 660681
Fax +39 02 6124945
[email protected]
www.weidmuller.it
Jordan
HORIZONS
P.O.Box: 330607
Amman Jordan 11133
Phone +962 6 4882114
Fax +962 6 4882115
[email protected]
JP
Japan
Nihon Weidmüller Co. Ltd.
Sphere Tower Tennoz,
2-2-8 Higashi-Shinagawa,
Shinagawa-Ku,
Tokyo 140-0002
Phone +81 3 6711-5300
Fax +81 3 6711-5333
www.weidmuller.co.jp
Korea
Weidmuller Korea Co. Ltd.
6F Seokyoung B/D,
242-54 Nonhyun-dong,
Gangnam-gu
Seoul, 135-830
Phone +82 2 5160003
Fax +82 2 5160090
[email protected]
Kuwait
KANA CONTROLS General
Trading & Cont. CO. W.L.L.
Al Rai Industrial Area,
Plot 28-30, St. 31
P.O.Box: 25593
Safat, 13016
Phone +966-474 1373/4
Fax +966-474 1537
[email protected]
LB
Lebanon
Progress Engineering &
Trading Enterprises
Al Nahr Street, Beirut
Phone +961 1 444664
Fax +961 1 561880
[email protected]
LT
Lithuania
Representative Office
Weidmüller Interface
GmbH & Co. KG
Udens str. 12-118
Riga, LV-1007
Latvia
Phone +371 29254766
Fax +371 67624562
ilgonis.rudaks@
weidmueller.com
ELEKTROS IRANGA
Tinklu g.29a, 5319 Panevezys
Phone +370 45582828
Fax +370 45582727
[email protected]
LU
Luxembourg
Please contact
Weidmüller Benelux B.V.
in the Netherlands
LV
Latvia
Representative Office
Weidmüller Interface
GmbH & Co. KG
Udens str. 12-118
Riga, LV-1007
Latvia
Phone +371 29254766
Fax +371 67624562
ilgonis.rudaks@
weidmueller.com
Iceland
Samey Automation Center
Lyngas 13, 210 Garoabaer,
Phone +354 510 5200
Fax +354 510 5201
[email protected]
JO
KR
KW
SIA "ABI4"
Daugavgrivas str. 31b
1007 Riga
Phone +371 67470999
Fax +371 67465637
[email protected]
MD
Moldova
BERHORD A&D srl
44, srt. Sarmizegetusa 37/3
Off 414. b-dul Decebal, 3,
Chisinau, MD 2001
Phone +373 22 507137
Fax +373 22 507134
[email protected]
ME
Montenegro
Representative Office
Weidmüller Interface
GmbH & Co. KG
Beograd-Stari Grad
Danice Marković 2
11050 Beograd
Srbija
Phone +381 11 288 5274
Fax +381 11 288 5274
zoran.rabrenovic@
weidmueller.com
MK
Macedonia
Representative Office
Weidmüller Interface
GmbH & Co. KG
Beograd-Stari Grad
Danice Marković 2
11050 Beograd
Srbija
Phone +381 11 288 5274
Fax +381 11 288 5274
zoran.rabrenovic@
weidmueller.com
ELEKTRO – SMK dooel
UL. III Makedonska brigada b.b.
1000 Skopje
Phone +389 22 460 295
Fax +389 22 460 298
[email protected]
Croatia
Elektro Partner d.o.o.
Slavonska Avenija 24/6
10000 Zagreb
Phone +385 1 6184793
Fax +385 1 6184795
[email protected]
1366860000 – 2013
MT
Malta
E. S. S., Electrical Supplies
& Services Ltd
104 J. Sciberras Str.
Hamrun HMR 08
Phone +356 21 255 777
Fax +356 21 255 999
[email protected]
MU
Mauritius
MUBELO Electrical Ltd
Office 26, Gateway building,
St Jean Road, Quatre Bornes
Phone +230 467 0989
Fax +230 465 4051
[email protected]
MX
MY
NL
NO
NZ
Mexico
W Interconnections,
S.A. DE C.V.
Blvd. Hermanos Serdán
No. 698
Col. San Rafael Oriente
Puebla, C.P. 72029
Phone +52 222 22686227
[email protected]
Malaysia
Connect Plus Technology
Sdn Bhd
No. 43, Jalan PJS, 11/22,
Bandar Sunway,
46150 Petaling Jaya
Selangor Darul Ehsan
Phone +60 3 5633 7363
Fax +60 3-5633 6562
[email protected]
www.cptech.com.my
Netherlands
Weidmüller Benelux B.V.
Franciscusweg 221
1216 SE Hilversum
Postbus 1505
1200 BM Hilversum
Phone +31 35 6261261
Fax +31 35 6232044
[email protected]
www.weidmuller.nl
Norway
Siv. Ing. J. F. Knudtzen A/S
Billingstadsletta 97
P.O. Box 160
1378 Nesbru
Phone +47 66 983350
Fax +47 66 980955
[email protected]
www.jfknudtzen.no
PK
Pakistan
Kana Controls (Pak)
Apartment No. 33 C III
Chenab Block,
Allama Iqbal Town
Lahore, Pakistan
Phone +92 42 5419948
+92 42 7845160
Fax +92 42 5422895
[email protected]
www.kanapak.com
PL
Poland
Weidmüller Sp. z o.o.
Ul. Goledzinowska 10
03-302 Warszawa
Phone +48 22 5100940
Fax +48 22 5100941
[email protected]
www.weidmuller.pl
PT
QA
RO
RS
New Zealand
Cuthbert S. Steward Limited
27 Te Puni Street
POB 38496
Petone, Wellington
Phone +64 4 5686156
Fax +64 4 5686056
[email protected]
OM
Oman
DAN INTERNATIONAL LLC.
PO.BOX 2901
111 Seeb
Phone +968 503 677
Fax +968 503 755
[email protected]
PE
Peru
IMPEXINCA S.A.C.
Calle Ortiz de Zevallos N°105,
18 Lima, Miraflores,
Phone +511 447 5608
[email protected]
Philippines
Enclosure Systems Specialists Inc
Room 103 Narra Building
2276 Don Chino Roces
Avenue
Makati City 1231
Phone +63 2 813 8580
Fax +63 2 813 8596
[email protected]
1366860000 – 2013
Qatar
Doha Motors Trading Co.
(Technical Division)
Post Box No. 145
Airport Road
Doha - Qatar
Phone +974 465 1441
Fax +974 465 0925
[email protected]
Serbia
Representative Office
Weidmüller Interface
GmbH & Co. KG
Ustanicka 189, III sprat,
lokal 7a
11050 Beograd
Phone +381 11 288 5274
Fax +381 11 288 5274
zoran.rabrenovic@
weidmueller.com
RU
Russia
OOO Weidmüller
Warshavskoye highway, 25A,
bld. 6
117105 Moskau
Phone +7 4 95 771-6940
Fax +7 4 95 771-6941
[email protected]
www.weidmueller.ru
SA
Saudi-Arabia
Al Abdulkarim Holding Co.
P.O Box. 4
Dammam 31411
Phone +9668337110
Fax +9668338242
[email protected]
www.weidmueller.ae
Saudi Electric Supply Co.
P.O. Box 3298
Al Khobar 31952
Phone +966 3 882 9546227
Fax +966 3 882 9547
[email protected]
SE
Singapore
Weidmuller Pte. Ltd.
70 Bendemeer Road
#04-03 Luzerne
Singapore 339940
Phone +65 6841 5311
Fax +65 6841 5377
[email protected]
www.weidmuller.com.sg
SI
Slovenia
ELEKTROSPOJI d.o.o.
Stegne 25, 1000 Ljubljana
Phone +386 15113810
Fax +386 15111604
[email protected]
www.elektrospoji.si
SK
TH
Sweden
Weidmüller AB
Axel Daniessons väg 271
P.O. box 31025
200 49 Malmö
Phone +46 (0) 7 71 43 00 44
Fax +46 (0) 40 37 48 60
[email protected]
www.weidmuller.se
Thailand
Pisanu Engineering Co., Ltd
800/43-45 Soi Trakulsuk
Asoke-dindaeng Road,
Dindaeng, Bangkok 10400
Phone +66 2 245 9113
Fax +66 2 6429220
[email protected]
www.pisanu.co.th
Tunisia
Please contact
Weidmüller E.U.R.L.
in France
TR
Turkey
Weidmüller Elektronik Ticaret
Ltd. Sirketi
Kavacik Mah. Orhan Veli Kanik
Caddesi 9/1
34810 Beykoz – Istanbul
Phone +90 216 5371070 (Pbx)
Fax +90 216 5371077
[email protected]
www.weidmuller.com.tr
TW
VE
Venezuela
Somerinca C.A.
Quinta Sagrado Corazon
de Jesus 3ra Transversal Los Dos Caminos,
Caracas 1070 - A
Phone +58 212 2352748
Fax +58 212 2399341
[email protected]
www.kmsomerinca.com.ve
VN
Vietnam
AUMI Co., Ltd
E1, La Thanh Hotel,
218 Doi Can Street,
Lieu Giai Ward, Ba Dinh District,
Hanoi City
Phone +84 4762 8601
Fax +84 4266 1391
[email protected]
Slovakia
ELEKTRIS s.r.o.
Elektrárenská 1
83104 Bratislava
Phone +421 2 49200113
Fax +421 2 49200119
[email protected]
TN
Romania
Rominterface Impex SRL
Str. Gh. Dem Teodorescu 30 A
30916 Bucuresti - sector 3
Phone +40 21 3220230
Fax +40 21 3228857
[email protected]
ES-YU Elektrosistem
Pariske komune 41
11070 Novi Beograd, Serbia
Phone +381 11 3018660
Fax +381 11 2693608
[email protected]
J & W CIA. S.A.
Calle 6 Mz. D Lte. 23
Urb. Ind. Grimanesa
Callao 01
Phone +51 1 57 22539
Fax +51 1 57 20152
[email protected]
www.jwcia.com
PH
Portugal
Weidmüller Sistemas de
Interface S. A.
Estrada Outeiro Polima,
R. Augusto
Dias da Silva, Lote B, Esct. 2
2785-515 Abóboda -São
Domingos de Rana
Phone +351 21 4459191
Fax +351 21 4455871
www.weidmueller.pt
SG
Taiwan
Fittatek Co., Ltd.
12F No. 185 Fu-Kuo Road,
Tso Ying Dist, Kaohsiung
Phone +886 7 556 0858
Fax +886 7 556 3279
[email protected]
www.fittatek.com.tw
DE
Agency abroad
DE
Without own Agency
DE
Addresses worldwide
Group companies
Linh Kim Hai Co,. Ltd
78 Hoa Cuc Street Ward 7,
Phu Bhuan District,
Ho Chi Minh City
Phone +84 8517 1717
Fax +84 8517 1818
[email protected]
ZA
South Africa
Phambili Interface (Pty) Ltd
P.O. Box 193,
1609 Johannesburg
5 Bundo Road, Sebenza
1610 Johannesburg,
Endenvale
Phone +27 11 452 1930
Fax +27 11 452 6455
[email protected]
www.radinterface.co.za
DE
Other countries
Weidmüller Interface GmbH
& Co. KG
Postfach 3030
32720 Detmold
Klingenbergstraße 16
32758 Detmold
Phone +49 5231 14-0
Fax +49 5231 14-292083
[email protected]
www.weidmueller.com
Eucan Enterprise Ltd.
No. 145 He Ping 2nd Rd
Kaohsiung
Phone +886 7 715 6610
Fax +886 7 715 8748
[email protected]
www.eucan.com.tw
UA
Ukraine
TEKO INTERFACE
Lomonosova str. 73g
03022 Kiev
Phone +38 044 3740640
Fax +38 044 3740642
[email protected]
www.tekointerface.com.ua
US
United States
W-Interconnections Inc.
821 Southlake Boulevard,
Virginia - Richmond 23236
Phone +1 804 7942877
Fax +1 804 3792593
[email protected]
www.weidmuller.com
UY
Uruguay
REWO Uruguay S.A
AV. Bolivia 2001 Esq Rocafuerte
Carrasco Montevideo 11300
Phone / Fax +598 260 48439
[email protected]
UZ
Usbekistan
OOO “Elektro Potential”
Gani Mavljanova str., 2B
100084 Tashkent
Phone +998 98-3003821
Fax +998 71-1249286
[email protected]
X
X.5
X.3
Index
We cannot guarantee that there are no mistakes in the
publications or software provided by us to the customer for the
purpose of making orders. We try our best to quickly correct
errors in our printed media.
X
All orders are based on our general terms of delivery, which can
be reviewed on the websites of our group companies where you
place your order. On demand we can also send the general terms
of delivery to you.
X.6
1366860000 – 2013
Weidmüller – Partner in Industrial Connectivity
As experienced experts we support our customers and partners around the world
with products, solutions and services in the industrial environment of power,
signal and data. We are at home in their industries and markets and know the
technological challenges of tomorrow. We are therefore continuously developing
innovative, sustainable and useful solutions for their individual needs. Together we
set standards in Industrial Connectivity.
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
32758 Detmold, Germany
T +49 5231 14-0
F +49 5231 14-292083
[email protected]
www.weidmueller.com
Order number: 1366860000/11/2012/SMDM