Switch-Mode and Uninterruptible Power Supplies, Electronic Fuses Catalogue 2013 Power Supply The World of Industrial Connectivity As experienced experts we support our customers and partners around the world with products, solutions and services in the industrial environment of power, signal and data. Immerse yourself in our world of Industrial Connectivity. Let’s connect. DATA Automation Device Signal or power electronics JACKPAC ® IP 68 PCB terminals Media converter Switches FrontCom ® Micro Service interface Power supplies IE-LINE plug-in connectors Active sensoractuator-interfaces PCB connectors IE-LINE Connection components Surge protection Terminal rail outlet Fieldbus distributors Electronics housings Signal converters Solid-state relays Passive sensor-actuatorinterfacesand cables Relay modules SIGNAL Modular Terminal Blocks POWER Cable glands Interface Units Surge protection for Instrumentation & Control equipment Stud terminals Cabinet FieldPower® Enclosures and accessories Heavy-duty connectors Tools and identification systems Cutting tools Stripping tools Crimping tools More tools Software Printer Markers Dear Customers, The PDF versions of our catalogues offer practical additional functions, helping you to find your way around our product range and simplifying the ordering process. In addition to the catalogue, the PDF also contains: • Internal page links • Links to the online catalogue Try it out for yourself. Click the order number to obtain more detailed information and close-up images via you web browser. The links in the PDF file also enable you to go directly to the next desired catalogue page. Further Weidmüller product catalogues can be accessed by clicking the following: 4.5 PLC-system cabling 6 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 32758 Detmold, Germany T +49 5231 14-0 F +49 5231 14-292083 [email protected] www.weidmueller.com Order number: 1327330000/06/2012/SMDM PLC-system cabling Connectivity and electrical installation Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 32758 Detmold, Germany T +49 5231 14-0 F +49 5231 14-292083 [email protected] www.weidmueller.com Order number: 1327490000/11/2012/SMDM Power supply Switched-mode and uninterruptible power supplies, and electronic fuses Catalogue 2013 Let’s connect. Digital Signal Processing 7 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 32758 Detmold, Germany T +49 5231 14-0 F +49 5231 14-292083 [email protected] www.weidmueller.com Order number: 1366860000/11/2012/SMDM Weidmüller – Partner in Industrial Connectivity 9 Industrial Ethernet Catalogue 2013 Let’s connect. As experienced experts we support our customers and partners around the world Markers, with printers, software products, solutions and services in the industrial environment of power, signal and data. We are at home in their industries and markets and know the Cataloguetechnological 2013/2014 challenges of tomorrow. We are therefore continuously developing innovative, sustainable and useful solutions for their individual needs. Together we Let’s connect. set standards in Industrial Connectivity. Order number: 1366810000/03/2013/SMDM Power supply Catalogue 2013 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 32758 Detmold, Germany T +49 5231 14-0 F +49 5231 14-292083 [email protected] www.weidmueller.com Order number: 1327250000/04/2012/SMDM Weidmüller – Partner in Industrial Connectivity As experienced experts we support our customers and partners around the world Tools with products, solutions and services in the industrial environment of power, signal and data. We are at home in their industries and markets and know the Catalogue 2013 technological challenges of tomorrow. We are therefore continuously developing innovative, sustainable and useful solutions for their individual needs. Together we Let’s connect. set standards in Industrial Connectivity. Catalogue 2012/2013 Catalogue 2013 Surge protection Surge protection Weidmüller – Partner in Industrial Connectivity As experienced experts we support our customers and partners around the world PLC-interface units, with products, solutions front and servicesadapters in the industrial environment of power, signal and data. We are at home in their industries and markets and know the and prefabricated cables technological challenges of tomorrow. We are therefore continuously developing sustainable and useful solutions for their individual needs. Together we Cataloguesetinnovative, 2012/2013 standards in Industrial Connectivity. Let’s connect. Tools Weidmüller – Partner in Industrial Connectivity As experienced experts we support our customers and partners around the world Surge protection devices with products, solutions and services in the industrial environment of power, signal and data. We are at home in their industries and markets and know the Cataloguetechnological 2013challenges of tomorrow. We are therefore continuously developing innovative, sustainable and useful solutions for their individual needs. Together we Let’s connect. set standards in Industrial Connectivity. Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 32758 Detmold, Germany T +49 5231 14-0 F +49 5231 14-292083 [email protected] www.weidmueller.com Order number: 1327190000/07/2012/SMDM 4.3 Industrial Ethernet Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 32758 Detmold, Germany T +49 5231 14-0 F +49 5231 14-292083 [email protected] www.weidmueller.com Order number: 1381510000/01/2013/SMDM Catalogue 2013 4.4 ound the world t of power, nd know the sly developing eds. Together we Analogue signal conditioning Weidmüller – Partner in Industrial Connectivity As experienced experts we support our customers and partners around the world Relay Modules and Solid-State Relays with products, solutions and services in the industrial environment of power, signal and data. We are at home in their industries and markets and know the challenges of tomorrow. We are therefore continuously developing Cataloguetechnological 2012/2013 innovative, sustainable and useful solutions for their individual needs. Together we set standards in Industrial Connectivity. Let’s connect. Markers, printers, software Catalogue 2013 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 32758 Detmold, Germany T +49 5231 14-0 F +49 5231 14-292083 [email protected] www.weidmueller.com 4.2 Catalogue 2012/2013 OMNIMATE – device connectivity Weidmüller – Partner in Industrial Connectivity As experienced experts we support our customers and partners around the world Signal converters, trip amplifiers and process meters with products, solutions and services in the industrial environment of power, signal and data. We are at home in their industries and markets and know the Cataloguetechnological 2012/2013 challenges of tomorrow. We are therefore continuously developing innovative, sustainable and useful solutions for their individual needs. Together we Let’s connect. set standards in Industrial Connectivity. Industrial marking system Catalogue 2013 OMNIMATE – device connectivity Modular terminal blocks Catalogue 2012/2013 Connectivity Order number: 1282250000/03/2012/SMDM Order number: 1366910000/11/2012/SMDM 4.1 Digital Signal Processing Weidmüller – Partner in Industrial Connectivity As experienced experts we support our customers and partners around the world PCB terminal blocks, with products, solutions andPCB services inconnectors, the industrial environmentpanel of power, signal and data. We are at home in their industries and markets and know the feedthrough terminal blocks and electronics technological challenges of tomorrow. We are therefore continuously developing housings sustainable and useful solutions for their individual needs. Together we Cataloguesetinnovative, 2013 standards in Industrial Connectivity. Let’s connect. Catalogue 2012/2013 2 Catalogue 2013/2014 Weidmüller – Partner in Industrial Connectivity As experienced experts we support our customers and partners around the world Modular terminal blocks with products, solutions and services in the industrial environment of power, signal and data. We are at home in their industries and markets and know the Catalogue technological 2012/2013 challenges of tomorrow. We are therefore continuously developing sustainable and useful solutions for their individual needs. Together we Let’s setinnovative, connect. standards in Industrial Connectivity. Analogue signal conditioning 1 he world ower, ow the veloping ogether we Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 32758 Detmold, Germany T +49 5231 14-0 F +49 5231 14-292083 [email protected] www.weidmueller.com Order number: 1381580000/11/2012/SMDM Industrial data communication Switch-Mode and Uninterruptible Power Supplies, Electronic Fuses Appendix Contents Switch-Mode and Uninterruptible Power Supplies, Electronic Fuses Catalogue 4.3 Switch-mode power supplies A Uninterruptible power supplies (UPS) B Fuse protection for 24 V DC circuits C Unregulated power supplies D IP 65 switched-mode power supply / Electrical cabinet socket outlet E Weidmüller Solutions & Service V W Glossary/Technical appendix Index 1366860000 – 2013 X Index Type / Index Order No. Addresses worldwide I Product overview Power supplies – Overview II connectPower 1ph PRO-M connectPower 3ph PRO-M connectPower PRO-M Extension modules •Single-phase switched-mode power supply modules, very slim design •High degree of efficiency •Power category 70...1,000 W •Up to five devices can be connected in parallel without a diode module •International approvals •3-phase switched-mode power supply modules, very slim design •High degree of efficiency •Power category 120...1,000 W •Up to five devices can be connected in parallel without a diode module •International approvals •Capacity module for increasing the peak current •Diode modules for redundant construction •Relay module for monitoring the output voltage connectPower PRO-M Application solutions connectPower 1ph PRO-H connectPower PRO-H Multi-phase •Wide-range input 85...264 V AC 80...430 V DC •Alarm relay •Metal snap-on foot •International approvals •Single-phase switch-mode power supplies •High MTBF values •Cl. I Div. 2 + ATEX •Performance class: 70 to 600 W •Output: 12, 24, 36 and 48 V DC •Multi-phase switch-mode power supplies •85...132 / 187...550 V AC •UL approval •Performance class: 180 to 600 W connectPower PRO-H Redundancy modules connectPower 1ph ECOLINE connectPower 3ph ECOLINE •15 A or 25 A •100 % load sharing •Remote On/Off •International approvals •Cl. I Div. 2 + ATEX •Single-phase switched-mode power supply modules •Compact form •Metal housing •Power category 70…1,000 W •International approvals •3-phase switched-mode power supply modules •Compact form •Metal housing •Power category 120…1,000 W •International approvals 1366860000 – 2013 Product overview connectPower ECOLINE Diode modules connectPower 1ph INSTAPOWER connectPower 1ph WAVEPOWER •Diode module for 100 % decoupling of switched-mode power supply modules •Optimum doubling of output power •Redundancy operation •Up to 40 A output current can be set •International approvals •Single-phase switched-mode power supply modules for the distribution board •Compact form •Power category 24 and 48 W •Universal input and output voltage 5…48 V •International approvals •Single-phase switched-mode power supply unit •Slim design 22.5 mm •Power category 12 W •International approvals connectPower 1ph connectPower 3ph connectPower DC/DC converters •Single-phase switched-mode power supply modules •Metal housing •Power category 55 W and 160 W •Universal input and output voltage 5…48 V •International approvals •300-watt performance category, with active PFC •3-phase switched-mode power supply modules •Metal housing •Up to 5 devices can be directly connected in parallel •Professional display and processing of all relevant signal states •International approvals •Compact form •Metal housing •Universal input and output voltage of 5 V to 48 V •International approvals connectPower UPS control unit connectPower battery module connectPower buffer module •Two 24 V models in 10 A/20 A and 40 A •Temperature-compensated charging feature, for a long battery life •Integrated battery diagnostics including continuous availability test •Status relay and additional transistor outputs for remote monitoring •Convenient LED displays for easy error analysis •Maintenance-free, lead-acid batteries from 1.3 Ah to 17 Ah •Integrated temperature sensor for optimal battery charging •Integrated fuse for reliable activation •Support capacity up to 40 A / 30 min or 10 A / 90 min •Robust metal housing for wall mounting •Maintenance-free UPS on a capacitor basis, with a capacity to support 20 A / 200 ms •Parallel switching to increase the output current or support time •Status notification via LED and relay contact 1366860000 – 2013 III Product overview Power supplies – Overview IV compactPower 1ph unregulated power supplies compactPower 3ph unregulated power supplies WAVEGUARD •Single-phase unregulated power supplies •Compact form •Standard voltage ~230/400 V to IEC38 +/– 15 V tap •Reliable short-circuit and overload protection •3-phase unregulated power supplies •Compact form •Nominal voltage to IEC38 +/- 5 V tap •Reliable short-circuit and overload protection •Electronic fusing •Visual fault indication and potential-free contact •Reset input •Compact form FieldPower® IP 65 switched-mode power supply Electrical cabinet socket outlet •3-phase switch-mode power supply unit, 24 V / 5 A on FieldPower® power bus, 5 x 2.5...6 mm² •Integrated input fuse •Decentralised 24 V DC generation and distribution for widely distributed facilities •Reduced voltage drops in DC systems •Increased energy efficiency because of minimal transmission losses •Simple installation in electrical cabinet •TS 35 module can be rail mounted •VDE mark of conformity •Two-pole with earthing contact 1366860000 – 2013 1366860000 – 2013 V Product overview Power supplies – Selection PRO-M Mains 1ph Input voltage 85...265 V AC, 80...370 V DC Input frequency 50 / 60 Hz CE, cURus, cULus; C-Tick, GL Output voltage 24 V Output current Order No. Page 3A 5A 7,5 A 10 A 20 A 8951330000 8951340000 8951350000 8951360000 8951370000 A.5 A.5 A.6 A.6 A.7 PRO-M expansion modules Mains 1ph Input voltage 85...265 V AC, 80...430 V DC, Input frequency 50 / 60 Hz CE, cURus*, cULus; C-Tick, GL Output voltage Diode module Diode module Output current 20 A 40 A 1222210000 A.10 Order No. Page Relay module Capacity module 1222220000 1222230000 1222240000 A.10 A.11 A.12 PRO-H Mains 1ph Input voltage 85...264 V AC, 85...132 / 187...265 V AC (Depending on model) Input frequency 50 / 60 Hz CE; UL; CSA; Class I Div.2; ATEX Zone 2 (Depending on model) Output voltage 12 V 12 V 24 V 24 V 24 V 24 V Output current 6A 12 A 3.8 A 3.8 A (CL 2) 7.5 A 15 A 1105430000 1105440000 1105790000 1194410000 1105810000 1105820000 A.17 A.17 A.18 A.18 A.19 A.19 Order No. Page VI Similar to illustration 1366860000 – 2013 Product overview PRO-M Mains 1ph / 3ph Input voltage 85...265 V AC, 120...300 V DC Input frequency 50 / 60 Hz CE, cURus, cULus; C-Tick Output voltage 1ph / 24 V Output current 40 A 5A 10 A 20 A 40 A 8951380000 8951390000 8951400000 8951410000 8951420000 A.7 A.8 A.8 A.9 A.9 Order No. Page 3ph / 24 V PRO-M application solutions Mains 1ph Input voltage 85...265 V AC, 80...430 V DC, Input frequency 50 / 60 Hz CE, cURus*, cULus; C-Tick, GL Output voltage 24 V Output current 10 A Order No. 1165480010 Page A.15 PRO-H Mains 1ph Input voltage 85...264 V AC, 85...132 / 187...265 V AC (Depending on model) Input frequency 50 / 60 Hz CE; UL; CSA; Class I Div.2; ATEX Zone 2 (Depending on model) Similar to illustration Similar to illustration Similar to illustration Output voltage 24 V 36 V 48 V 48 V 48 V 48 V Output current 25 A 16.5 A 2A 4A 7.5 A 12.5 A 1105840000 1194430000 1194420000 1105850000 1105860000 1105870000 A.20 A.20 A.21 A.21 A.22 A.22 Order No. Page 1366860000 – 2013 VII Product overview Power supplies – Selection PRO-H redundancy module 24 V DC CE, UL, UR, Class I Div.2; ATEX Output voltage 24 V 24 V Output current 15 A 20 A 1105880000 1105890000 A.25 A.25 Order No. Page INSTAPOWER Mains 1ph Input voltage 85...265 V AC, 120...300 V DC, 110...370 V DC* Input frequency 50 / 60 Hz CE, cURus*, cULus; class 2 * Not all models Output voltage Output current Order No. class 2 5V 12 V 2A 5A 1.5 A 4A 9928890005 8754960000 9928890012 8754970000 A.40 A.41 A.39 A.42 Page connectPower Mains 1ph Input voltage 85...265 V AC*, 120...300 V DC* Input frequency 50 / 60 Hz CE, UR / UL, CSA * Not all models Output voltage Output current Order No. Page VIII 5V 15 V 24 V 3A 8A 3A 8A 2.3 A 9927480005 9925340005 9927480012 9925340012 9927480024 A.47 A.49 A.47 A.49 A.46 1366860000 – 2013 Product overview PRO-H Mains 1ph/2ph Input voltage *400...500 V AC, *100...500 V AC *depending on model Input frequency 50 / 60 Hz CE; UL; UR; Similar to illustration Similar to illustration Similar to illustration 100...500 V AC 100...500 V AC 100...500 V AC Output voltage 24 V 24 V 24 V Output current 7.5 A 15 A 25 A 1194480000 1194490000 1194310000 A.23 A.23 A.24 Rated input voltage Order No. Page INSTAPOWER Mains 1ph Input voltage 85...265 V AC, 120...300 V DC, 110... 370 V DC Input frequency 50 / 60 Hz CE, cURus*, cULus; class 2 * Not all models class 2 Output voltage 15 V Output current 1.5 A 1A 2A 1A 1A 9928890015 9928890024 8739140000 9928890028 8879230000 A.39 A.38 A.43 A.38 A.44 6.5 A 12.5 A 1.04 A 3.5 A 2.3 A 9925340024 9916250024 9927480048 9925340048 9917790324 A.48 A.50 A.46 A.48 A.51 Order No. Page 24 V 28 V 48 V connectPower Mains 1ph / 3ph Input voltage 85...265 V AC*, 120...300 V DC* Input frequency 50 / 60 Hz CE, UR / UL, CSA * Not all models Output voltage Output current Order No. Page 1366860000 – 2013 1ph / 24 V 1ph / 48 V 3ph / 24 V IX Product overview Power supplies – Selection ECOLINE Mains 1ph Input voltage 90...265 V AC Input frequency 50 / 60 Hz Partially switchable from 115 / 230 V AC CE, cURus*, cULus*; GL*, GOST * Not all models Output voltage 24 V Output current Order No. Page 3A 5A 10 A 20 A 40 A 8708660000 8708670000 8708680000 8778870000 8862780000 A.28 A.29 A.30 A.31 A.32 ECOLINE diode modules 40 V DC max. CE, cURus, cULus; GOST Output voltage 40 V Output current Order No. Page 2 x 10 A 2 x 20 A 8710620000 8768650000 A.37 A.37 connectPower DC/DC converter Input voltage 9...16 V DC CE, UL / UR, CSA, Class 1, Div.2 Output voltage 12 V 15 V Output current 3A 3A 2A 9919371212 9919371215 9919371224 A.53 A.53 A.53 Order No. Page X 24 V 1366860000 – 2013 Product overview ECOLINE Mains 3ph Input voltage 3x 340...575 V AC, Input frequency 50 / 60 Hz CE, cURus, cULus; GL*, GOST * Not all models Output voltage 24 V Output current Order No. 5A 10 A 20 A 40 A 8862730000 8708700000 8708710000 8708730000 A.33 A.34 A.35 A.36 Page WAVEPOWER Mains 1ph 85...264 V AC 120...300 V DC CE, UL, CSA Output voltage 24 V Output current 0.5 A Order No. 9918840024 Page A.45 connectPower DC/DC converter Input voltage 18...30 V DC CE, UL / UR, CSA, Class 1, Div.2 Output voltage 5V 12 V 15 V 24 V 24 V Output current 8A 3A 3A 2A 10 A 9919372405 9919372412 9919372415 9919372424 1313320010 A.54 A.54 A.52 A.52 A.57 Order No. Page 1366860000 – 2013 XI Product overview Power supplies – Selection UPS control unit Buffer module Input voltage 20 ... 30 V DC Input voltage 22.5 ... 30 V DC CE, TÜV, cURus*, cULus*, GL* CE, TÜV, cURus, cULus, GL* * in preparation Output voltage 24 V 24 V * in preparation Output voltage 24 V DC Output current max. 24 A max. 48 A Output current max. 22 A 1370050010 1370040010 B.5 B.5 Order No. Page Order No. 1251220000 Page B.8 WAVEGUARD with screw connection Rated voltage 24 V DC CE, cURus Output voltage Output current Order No. Page 24 V 1.6 A 3.15 A 6.3 A 8A 0.5...5 A 8618890000 8618910000 8618930000 8618940000 8710270000 C.4 C.4 C.5 C.5 C.6 compactPower 1ph unregulated power supplies Mains 1ph Input voltage 230 V / 400 V ± 15 V Input frequency 50 / 60 Hz CE, cURus, cULus Output voltage Output current Order No. Page XII 24 V 1.5 A 3A 6A 8A 11 A 18 A 8575260000 8575270000 8575280000 8575300000 8575310000 8575320000 D.4 D.4 D.5 D.5 D.6 D.6 1366860000 – 2013 Product overview Battery module Rated voltage 24 V DC 24 V DC 24 V DC 24 V DC Nominal capacity 1,3 Ah 3,4 Ah 7,2 Ah 12 Ah 17 Ah in preparation 1251070000 1251080000 1251090000 1251110000 B.6 B.6 B.7 B.7 1.6 A 3.15 A 6.3 A 8A 0.5...5 A 8621040000 8621030000 8621020000 8621010000 8727630000 C.4 C.4 C.5 C.5 C.6 Order No. Page 24 V DC WAVEGUARD with tension clamp connection Rated voltage 24 V DC CE, cURus Output voltage Output current Order No. Page 24 V compactPower 3ph unregulated power supplies Mains 3ph Input voltage 3x 400 V ± 5 % Input frequency 50 / 60 Hz CE, cURus, cULus Output voltage Output current Order No. Page 1366860000 – 2013 24 V 11 A 18 A 22 A 26 A 32 A 42 A 8628620000 8628630000 8628650000 8628660000 8628670000 8628680000 D.7 D.7 D.8 D.8 D.9 D.9 XIII Product overview Power supplies – Selection FieldPower® IP65 switched-mode power supply Mains 3ph Input voltage 400 V AC Output voltage 24 V Output current 5A 5A 1132320000 1101940000 E.6 E.7 Order No. Page 24 V Electrical cabinet socket outlet Earthed socket outlet for the TS35 mounting rail VDE Output voltage Output current Order No. Page XIV 250 V AC 16 A 8734580000 E.24 1366860000 – 2013 Switch-mode power supplies Contents Switch-mode power supplies Switch-mode power supplies 1366860000 – 2013 Overview A.2 connectPower PRO-M A.4 connectPower PRO-H A.16 connectPower ECOLINE A.28 connectPower INSTAPOWER A.38 connectPower WAVEPOWER A.45 connectPower A.46 connectPower DC/DC converter A.52 A A.1 Switch-mode power supplies Switch-mode power supplies – Overview Switch-mode power supplies The switch-mode power supplies feature a high degree of efficiency, compact dimensions and minimal heat generation. A They are an excellent, reliable solution for providing power in all automation applications – safely providing 24 V DC voltage. The different product series are optimised for the automation industry: they feature Ex approvals for the processing industry, a flat shape perfect for distribution tasks within buildings, or provide decentralised control voltages. are possible using simple parallel circuitry. Weidmüller switch-mode power supplies can be depended upon for all applications because of their high efficiency and their resistance to both short circuits and overloads. Wedimüller offers a system of one- and three-phase swtichmode power supplies especially for the PRO-M family. These can be expanded with additional modules to create whole system solutions. The appropriate system can be assembled for any type of application: with redundancy circuits containing decoupled outputs, monitoring of the output voltage or triggering of circuit breakers. All-purpose usage: with a wide range of AC/DC inputs, single-, double- or three-phase versions, and a wide temperature range. Additional performance increases A.2 1366860000 – 2013 Switch-mode power supplies Switch-mode power supplies – Overview AC / DC International use Parallel connection from 3 3 mm A A wide-range input (both DC as well as AC voltages can be used; no switching required) and extensive approvals (UL/CSA and GL (EMC 1 – bridge)). connectPower Module power can be increased by connecting upto five power supplies in parallel without diode module. connectPower PRO-M Narrow connectPower PRO-H Space-saving configuration in the switching cabinet through very narrow housing construction and side-by-side connectability. connectPower ECOLINE Robust Wide temperature range from –25 °C … +70 °C. connectPower INSTAPOWER Wide choice The right power supply for every application: 1-phase 3 A, 5 A, 7.5 A, 10 A, 20 A, 40 A and 3-phase 5 A, 10 A, 20 A, 40 A. connectPower WAVEPOWER connectPower connectPower DC/DC converters 1366860000 – 2013 A.3 Switch-mode power supplies connectPower PRO-M connectPower PRO-M A % { \u " Technical data L (+) AC N (–) + DC PE – Pay attention to polarity of DC connection L1 (+) L2 (–) L3 PE AC + DC – Two-Phase operation also possible Max. limiting average on state current [A] Type\Temp. 1ph 24V / 3A 1ph 24V / 5A 1ph 24V / 7.5A 1ph 24V / 10A 1ph 24V / 20A 1ph 24V / 40A 3ph 24V / 5A 3ph 24V / 10A 3ph 24V / 20A 3ph 24V / 40A 45°C 3.6 6 9 12 24 48 6 12 24 48 50°C 3.4 5.7 8.5 11.3 22.7 45.3 5.7 11.3 22.7 45.3 55°C 3.2 5.3 8 10.7 21.3 42.7 5.3 10.7 21.3 42.7 60°C 3 5 7.5 10 20 40 5 10 20 40 Project-planning data Type Rated input voltage Mains voltage range Mains input current Rec. fuse [char.] Efficiency @ 230 V AC, @ 3x400 V AC Rated power loss [W] Installation width Input terminals Conductor, solid min/max Conductor, flexible min/max Conductor, AWG/kcmil min/max Output terminals Number plus/minus Conductor, solid min/max Conductor, flexible min/max Conductor, AWG/kcmil min/max A.4 mm 65°C 2.6 4.4 6.6 8.8 17.5 35 4.4 8.8 17.5 35 General technical data Current limiting Ambient temp. operating / storage temperature Max. perm. air humidity (operation) Degree of protection Class of protection Pollution degree Insulation voltage input/output MTBF Protection against reverse voltages from the load Parallel connection option Housing version Indication Mounting position, installation notice EMC / shock / vibration Noise emission acc. to EN55022 Noise immunity tests acc. to 70°C 2.3 3.8 5.6 7.5 15 30 3.8 7.5 15 30 24 V / 5 A 1.3...0.6 A 2 A / D I / II 6 A, [B] 2...4 A, [C] 90 % 8W 33 2.1...0.9 A 4 A / D I / II 6 A, [B] 3...5 A, [C] 90 % 13 W 40 24 V / 7.5 A 24 V / 10 A 1 - phase 100...240 V AC 85...264 V AC 2.1...0.9 A 2.8...1.2 A 6 A / D I / II 6 A / D I / II 10 A, [B] 10 A, [B] 5...10 A, [C] 5...10 A, [C] 91 % 90 % 18 W 27 W 50 60 Acc. to EN60204 Acc. to EN61558-2-17 Acc. to EN50178 / VDE0160 SELV acc. to EN60950, PELV acc. to EN60204 VDE0100-410 / acc. to DIN57100-410 Acc. to VDE0106-101 24 V / 20 A 24 V / 40 A 24 V / 5 A 5.6...2.4 A 10 A / D I / II 20 A, [B] 10...12 A, [C] 90 % 53 W 121 11.1...4.7 A 16 A / D I / II 25 A, [B] 14...16 A, [C] 91 % 95 W 180 0.3...0.28 A 2 A / D I / II 1...2 A, [C] 90 % 13 W 40 0.5...6 0.5...2.5 26 / 12 Screw connection 0.5...6 0.5...2.5 26 / 10 0.5...6 0.5...2.5 26 / 12 Screw connection 2/3 0.5...6 0.5...16 0.5...2.5 2.5...10 26 / 10 22 / 6 2/2 mm2 mm2 Class B EN61000-4-2 (ESD), EN61000-4-3 und EN61000-4-8 (Fields), EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN610004-6 (conducted), EN61000-4-11 (Dips) Acc. to EN 61000-3-2 Acc. to EN50178, shock: 30 g in all directions Limiting of mains voltage harmonic currents Resistance against vibration and shock Electrical safety (applied standards) Electrical equipment of machines Safety transformers for switched-mode power units Machinery with electronic equipment Safety extra-low voltage Protective separation / protection against electrical shock Protection against dangerous shock currents 24 V / 3 A mm2 mm2 > 120 % IN –25 °C…+70 °C / –40 °C… +85 °C 5 %…95 % RH IP20 I, with PE connection 2 3 kV I/O / 2 kV I/earth / 0.5 kV O/earth > 500.000 h acc. to IEC 1709 (SN29500) 30…35 V DC yes, without diode module metal, corrosion resistant operation, green LED horizontal on mounting rail TS35, 50 mm spacing top and bottom for free air circulation, can be mounted side by side with no space in between 24 V / 10 A 24 V / 20 A 3 - phase 3 x 400...500 V AC 3 x 320...575 V AC 0.55...0.5 A 1.0...0.9 A 2 A / D I / II 2 A / D I / II 2...3 A, [C] 3...5 A, [C] 90 % 90 % 27 W 53 W 60 121 0.08...4 0.5...2.5 28 / 12 0.5...6 0.5...2.5 26 / 12 0.5...6 0.5...2.5 26 / 12 24 V / 40 A 2.5...2.0 A 4 A / D I / II 10 A, [B] 6...8 A, [C] 91 % 95 W 180 0.5...6 0.5...2.5 26 / 12 0.5...6 0.5...2.5 26 / 10 0.5...16 2.5...10 22 / 6 1366860000 – 2013 connectPower PRO-M CP M SNT 70W 24V 3A Switch-mode power supplies connectPower PRO-M CP M SNT 120W 24V 5A A D L (+) N (–) H AC PE + N (–) DC – With DC connection, note polarity W L (+) AC + DC PE – With DC connection, note polarity Technical data Input Rated input voltage Input voltage range AC Frequency range AC DC input voltage range AC current consumption DC current consumption Input fuse (internal) / making current Recommended back-up fuse Output Rated output voltage Output voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC Powerboost @ 24 V DC, 60 °C General data Degree of efficiency Power factor (approx.) AC failure bridging time @ INom Parallel connection option Height x width x depth Weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil min/max Note mm² mm² 100...240 V AC (wide-range input) 85…264 V AC (Derating @ 100 V AC) 47...63 Hz 80…370 V DC (Derating @ 120 V DC) 0.6 A @ 230 V AC / 1.1 A @ 115 V AC 0.25 A @ 370 V DC / 0.7 A @ 120 V DC Yes / max. 40 A 2 A / DI, safety fuse 6 A, Char. B, circuit breaker 2...4 A, Char. C, circuit breaker 100...240 V AC (wide-range input) 85…264 V AC (Derating @ 100 V AC) 47...63 Hz 80…370 V DC (Derating @ 120 V DC) 1.1 A @ 230 V AC / 2.0 A @ 115 V AC 0.4 A @ 370 V DC / 1.2 A @ 120 V DC Yes / max. 40 A 4 A / DI, safety fuse 6 A, Char. B, circuit breaker 3...5 A, Char. C, circuit breaker 24 V DC ± 1 % 22.5...29.5 V DC (adjustable via potentiometer on front) < 50 mVSS @ 24 V DC, IN 3 A @ 60 °C 3.6 A @ 45 °C, 3.2 A @ 55 °C, 2.3 A @ 70 °C 3.6 A for 1 min, ED = 5 % 24 V DC ± 1 % 22.5...29.5 V DC (adjustable via potentiometer on front) < 50 mVSS @ 24 V DC, IN 5 A @ 60 °C 6.0 A @ 45 °C, 5.3 A @ 55 °C, 3.8 A @ 70 °C 6 A for 1 min, ED = 5 % 90 % @ 230 V AC / 88 % @ 115 V AC > 0.6 @ 230 V AC / > 0,65 @ 115 V AC > 20 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 5 130 / 33 / 125 mm 0.57 kg 90 % @ 230 V AC / 88 % @ 115 V AC > 0.5 @ 230 V AC / > 0.6 @ 115 V AC > 100 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 5 130 / 40 / 125 mm 0.7 kg cULus; cURus; GL; GOSTME25 CE; cULus; cURus; GL; GOSTME25 Input Screw connection 3 for L/N/PE 0.5 / 6 0.5 / 2.5 26 / 12 Output Screw connection 4 (++ / --) 0.5 / 6 0.5 / 2.5 26 / 12 Input Screw connection 3 for L/N/PE 0.5 / 6 0.5 / 2.5 26 / 12 Output Screw connection 5 (++ / ---) 0.5 / 6 0.5 / 2.5 26 / 12 *) Recommendation applies only to AC operation; the max. permissible operating voltage is to be observed in all cases! *) Recommendation applies only to AC operation; the max. permissible operating voltage is to be observed in all cases! Type CP M SNT 70W 24V 3A CP M SNT 70W 24V 3A Type CP M SNT 120W 24V 5A CP M SNT 120W 24V 5A Ordering data Plastic clip-on foot Metal clip-on foot Qty. 1 1 Order No. 8951330000 8951330010 Qty. 1 1 Order No. 8951340000 8951340010 Note Accessories Note 1366860000 – 2013 A.5 Switch-mode power supplies connectPower PRO-M connectPower PRO-M CP M SNT 180W 24V 7.5A CP M SNT 250W 24V 10A A D L (+) N (–) H AC + N (–) DC PE – With DC connection, note polarity W L (+) AC + DC PE – With DC connection, note polarity Technical data Input Rated input voltage Input voltage range AC Frequency range AC DC input voltage range AC current consumption DC current consumption Input fuse (internal) / making current Recommended back-up fuse Output Rated output voltage Output voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC Powerboost @ 24 V DC, 60 °C General data Degree of efficiency Power factor (approx.) AC failure bridging time @ INom Parallel connection option Height x width x depth Weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil min/max Note mm² mm² 100...240 V AC (wide-range input) 85…264 V AC (Derating @ 100 V AC) 47...63 Hz 80…370 V DC (Derating @ 120 V DC) 0.9 A @ 230 V AC / 1.8 A @ 115 V AC 0.6 A @ 370 V DC / 1.7 A @ 120 V DC Yes / max. 40 A 6 A / DI, safety fuse 10 A, Char. B, circuit breaker 6 A, Char. C, circuit breaker 100...240 V AC (wide-range input) 85…264 V AC (Derating @ 100 V AC) 47...63 Hz 80…370 V DC (Derating @ 120 V DC) 1.2 A @ 230 V AC / 2.4 A @ 115 V AC 0.8 A @ 370 V DC / 2.3 A @ 120 V DC Yes / max. 12 A 4 A / DI, safety fuse 10 A, Char. B, circuit breaker 3...4 A, Char. C, circuit breaker 24 V DC ± 1 % 22.5...29.5 V DC (adjustable via potentiometer on front) < 50 mVSS @ 24 V DC, IN 7,5 A @ 60 °C 9.0 A @ 45 °C, 8.0 A @ 55 °C, 5.6 A @ 70 °C 9 A for 1 min, ED = 5 % 24 V DC ± 1 % 22.5...29.5 V DC (adjustable via potentiometer on front) < 50 mVSS @ 24 V DC, IN 10 A @ 60 °C 12 A @ 45 °C, 10.7 A @ 55 °C, 7.5 A @ 70 °C 12 A for 1 min, ED = 5 % 91 % @ 230 V AC / 88 % @ 115 V AC > 0.94 @ 230 V AC / > 0.99 @ 115 V AC > 20 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 5 130 / 50 / 150 mm 1.05 kg 90 % @ 230 V AC / 87 % @ 115 V AC > 0.99 @ 230 V AC / > 0.97 @ 115 V AC > 20 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 5 130 / 60 / 150 mm 1.2 kg CE; cULus; cURus; GL; GOSTME25 cULus; cURus; GL; GOSTME25 Input Screw connection 3 for L/N/PE 0.5 / 6 0.5 / 2.5 26 / 12 Output Screw connection 5 (++ / ---) 0.5 / 6 0.5 / 2.5 26 / 12 Input Screw connection 3 for L/N/PE 0.5 / 6 0.5 / 2.5 26 / 12 Output Screw connection 5 (++ / ---) 0.5 / 6 0.5 / 2.5 26 / 12 *) Recommendation applies only to AC operation; the max. permissible operating voltage is to be observed in all cases! *) Recommendation applies only to AC operation; the max. permissible operating voltage is to be observed in all cases! Type CP M SNT 180W 24V 7,5A CP M SNT 180W 24V 7,5A Type CP M SNT 250W 24V 10A CP M SNT 250W 24V 10A Ordering data Plastic clip-on foot Metal clip-on foot Qty. 1 1 Order No. 8951350000 8951350010 Qty. 1 1 Order No. 8951360000 8951360010 Note Accessories Note A.6 1366860000 – 2013 connectPower PRO-M CP M SNT 500W 24V 20A Switch-mode power supplies connectPower PRO-M CP M SNT 1000W 24V 40A A D L (+) N (–) H AC + N (–) DC PE – With DC connection, note polarity W L (+) AC + DC PE – With DC connection, note polarity Technical data Input Rated input voltage Input voltage range AC Frequency range AC DC input voltage range AC current consumption DC current consumption Input fuse (internal) / making current Recommended back-up fuse Output Rated output voltage Output voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC Powerboost @ 24 V DC, 60 °C General data Degree of efficiency Power factor (approx.) AC failure bridging time @ INom Parallel connection option Height x width x depth Weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil min/max Note mm² mm² 100...240 V AC (wide-range input) 85…264 V AC (Derating @ 100 V AC) 47...63 Hz 80…370 V DC (Derating @ 120 V DC) 2.4 A @ 230 V AC / 4.8 A @ 115 V AC 1.5 A @ 370 V DC / 4.6 A @ 120 V DC Yes / max. 5 A 6 A / DI, safety fuse 16 A, Char. B, circuit breaker 6...8 A, Char. C, circuit breaker 100...240 V AC (wide-range input) 85…264 V AC (Derating @ 100 V AC) 47...63 Hz 80…370 V DC (Derating @ 120 V DC) 4.7 A @ 230 V AC / 9.6 A @ 115 V AC 2.9 A @ 370 V DC / 9.1 A @ 120 V DC Yes / max. 5 A 16 A / DI, safety fuse 20 A, Char. B, circuit breaker 16 A, Char. C, circuit breaker 24 V DC ± 1 % 22.5...29.5 V DC(adjustable via potentiometer on front) < 50 mVSS @ 24 V DC, IN 20 A @ 60 °C 24 A @ 45 °C, 22.7 A @ 55 °C, 15 A @ 70 °C 24 A for 1 min, ED = 5 % 24 V DC ± 1 % 22.5...29.5 V DC (adjustable via potentiometer on front) < 50 mVSS @ 24 V DC, IN 40 A @ 60 °C 48 A @ 45 °C, 42.7 A @ 55 °C, 30 A @ 70 °C 48 A for 1 min, ED = 5 % 90 % at 230 V AC / > 85 % at 115 V AC > 0.98 @ 230 V AC / > 0.99 @ 115 V AC > 20 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 3 130 / 121 / 150 mm 2.2 kg 91 % @ 230 V AC / 88 % @ 115 V AC > 0.99 @ 230 V AC / > 0.99 @ 115 V AC > 20 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 5 130 / 180 / 150 mm 3.9 kg cULus; cURus; GL; GOSTME25 cULus; cURus; GL; GOSTME25 Input Screw connection 3 for L/N/PE 0.5 / 6 0.5 / 2.5 26 / 10 Output Screw connection 5 (++ / ---) 0.5 / 6 0.5 / 2.5 26 / 10 Input Screw connection 3 for L/N/PE 0.5 / 6 0.5 / 2.5 26 / 10 Output Screw connection 5 (++ / ---) 0.5 / 16 2.5 / 10 22 / 6 *) Recommendation applies only to AC operation; the max. permissible operating voltage is to be observed in all cases! *) Recommendation applies only to AC operation; the max. permissible operating voltage is to be observed in all cases! Type CP M SNT 500W 24V 20A CP M SNT 500W 24V 20A Type CP M SNT 1000W 24V 40A CP M SNT 1000W 24V 40A Ordering data Plastic clip-on foot Metal clip-on foot Qty. 1 1 Order No. 8951370000 8951370010 Qty. 1 1 Order No. 8951380000 8951380010 Note Accessories Note 1366860000 – 2013 A.7 Switch-mode power supplies connectPower PRO-M connectPower PRO-M CP M SNT3 120W 24V 5A CP M SNT3 250W 24V 10A A D L1 (+) L2 (–) L3 PE H AC + DC – With DC connection, note polarity Two-phase operation also possible W L1 (+) L2 (–) L3 PE AC + DC – With DC connection, note polarity Two-phase operation also possible Technical data Input Rated input voltage Input voltage range AC Frequency range AC DC input voltage range AC current consumption DC current consumption Input fuse (internal) / making current Recommended back-up fuse Output Rated output voltage Output voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC Powerboost @ 24 V DC, 60 °C General data Degree of efficiency Power factor (approx.) AC failure bridging time @ INom Parallel connection option Height x width x depth Weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil min/max Note mm² mm² 3 x 400...3 x 500 V AC (wide-range input) 3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 0.28 A @ 3 x 500 V AC / 0.3 A @ 3 x 400 V AC 0.18 A @ 800 V DC / 0.3 A @ 450 V DC No / max. 50 A 2 A / DI, safety fuse 2...3 A, Char. C, circuit breaker 3 x 400...3 x 500 V AC (wide-range input) 3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 0.5 A @ 3 x 500 V AC / 0.55 A @ 3 x 400 V AC 0.35 A @ 800 V DC / 0.6 A @ 450 V DC No / max. 50 A 2 A / DI, safety fuse 2...3 A, Char. C, circuit breaker 24 V DC ± 1 % 22.5...29.5 V DC (adjustable via potentiometer on front) < 50 mVSS @ 24 V DC, IN 5 A @ 60 °C 6.0 A @ 45 °C, 5.3 A @ 55 °C, 3.8 A @ 70 °C 6 A for 1 min, ED = 5 % 24 V DC ± 1 % 22.5...29.5 V DC (adjustable via potentiometer on front) < 50 mVSS @ 24 V DC, IN 10 A @ 60 °C 12 A @ 45 °C, 10.7 A @ 55 °C, 7.5 A @ 70 °C 12 A for 1 min, ED = 5 % 89 % @ 3 x 500 V AC / 90 % @ 3 x 400 V AC > 0.55 @ 3 x 500 V AC / > 0.65 @ 3 x 400 V AC > 50 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC yes, max. 5 130 / 40 / 125 mm 0.7 kg 89 % @ 3 x 500 V AC / 90 % @ 3 x 400 V AC > 0.65 @ 3 x 500 V AC / > 0.75 @ 3 x 400 V AC > 40 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC yes, max. 5 130 / 60 / 150 mm 1.25 kg cULus; cURus; GL; GOSTME25 cULus; cURus; GL; GOSTME25 Input Screw connection 4 for L1/L2/L3/PE 0.08 / 4 0.5 / 2.5 28 / 12 Output Screw connection 5 (++ / ---) 0.5 / 6 0.5 / 2.5 26 / 12 Input Screw connection 4 for L1/L2/L3/PE 0.5 / 6 0.5 / 2.5 26 / 12 Output Screw connection 5 (++ / ---) 0.5 / 6 0.5 / 2.5 26 / 12 *) Recommendation applies only to AC operation; the max. permissible operating voltage is to be observed in all cases! *) Recommendation applies only to AC operation; the max. permissible operating voltage is to be observed in all cases! Type CP M SNT3 120W 24V 5A CP M SNT3 120W 24V 5A Type CP M SNT3 250W 24V 10A CP M SNT3 250W 24V 10A Ordering data Plastic clip-on foot Metal clip-on foot Qty. 1 1 Order No. 8951390000 8951390010 Qty. 1 1 Order No. 8951400000 8951400010 Note Accessories Note A.8 1366860000 – 2013 connectPower PRO-M CP M SNT3 500W 24V 20A Switch-mode power supplies connectPower PRO-M CP M SNT3 1000W 24V 40A A D L1 (+) L2 (–) L3 PE H AC + DC – With DC connection, note polarity Two-phase operation also possible W L1 (+) L2 (–) L3 PE AC + DC – With DC connection, note polarity Two-phase operation also possible Technical data Input Rated input voltage Input voltage range AC Frequency range AC DC input voltage range AC current consumption DC current consumption Input fuse (internal) / making current Recommended back-up fuse Output Rated output voltage Output voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC Powerboost @ 24 V DC, 60 °C General data Degree of efficiency Power factor (approx.) AC failure bridging time @ INom Parallel connection option Height x width x depth Weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil min/max Note mm² mm² 3 x 400...3 x 500 V AC (wide-range input) 3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 0.9 A @ 3 x 500 V AC / 0.95 A @ 3 x 400 V AC 0.7 A @ 800 V DC / 1.2 A @ 450 V DC No / max. 50 A 4 A / DI, safety fuse 3...5 A, Char. C, circuit breaker 3 x 400...3 x 500 V AC (wide-range input) 3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 2.0 A @ 3 x 500 V AC / 2.5 A @ 3 x 400 V AC 1.3 A @ 800 V DC / 2.4 A @ 450 V DC No / max. 60 A 6 A / DI, safety fuse 10 A, Char. B, circuit breaker 6...8 A, Char, C, circuit breaker 24 V DC ± 1 % 22.5...29.5 V DC (adjustable via potentiometer on front) < 50 mVSS @ 24 V DC, IN 20 A @ 60 °C 24 A @ 45 °C, 21.3 A @ 55 °C, 15 A @ 70 °C 24 A for 1 min, ED = 5 % 24 V DC ± 1 % 22.5...29.5 V DC (adjustable via potentiometer on front) < 50 mVSS @ 24 V DC, IN 40 A @ 60 °C 48 A @ 45 °C, 42.7 A @ 55 °C, 30 A @ 70 °C 48 A for 1 min, ED = 5 % 89 % @ 3 x 500 V AC / 90 % @ 3 x 400 V AC < 0.69 @ 3 x 500 V AC / > 0.82 @ 3 x 400 V AC > 25 ms at 3 x 500 V AC / > 20 ms at 3 x 400 V AC yes, max. 3 130 / 121 / 150 mm 2.2 kg 91 % @ 3 x 500 V AC / 91 % @ 3 x 400 V AC > 0.6 @ 3 x 500 V AC / > 0.6 @ 3 x 400 V AC > 25 ms at 3 x 500 V AC / > 20 ms at 3 x 400 V AC yes, max. 3 130 / 180 / 150 mm 4 kg cULus; cURus; GL; GOSTME25 cULus; cURus; GL; GOSTME25 Input Screw connection 4 for L1/L2/L3/PE 0.5 / 6 0.5 / 2 26 / 10 Output Screw connection 5 (++ / ---) 0.5 / 6 0.5 / 2.5 26 / 10 Input Screw connection 4 for L1/L2/L3/PE 0.5 / 6 0.5 / 2.5 26 / 10 Output Screw connection 5 (++ / ---) 0.5 / 16 0.5 / 10 22 / 6 *) Recommendation applies only to AC operation; the max. permissible operating voltage is to be observed in all cases! *) Recommendation applies only to AC operation; the max. permissible operating voltage is to be observed in all cases! Type CP M SNT3 500W 24V 20A CP M SNT3 500W 24V 20A Type CP M SNT3 1000W 24V 40A CP M SNT3 1000W 24V 40A Ordering data Plastic clip-on foot Metal clip-on foot Qty. 1 1 Order No. 8951410000 8951410010 Qty. 1 1 Order No. 8951420000 8951420010 Note Accessories Note 1366860000 – 2013 A.9 Switch-mode power supplies connectPower PRO-M PRO-M: diode, capacity and relay modules CP M DM20 CP M DM40 A D 1+ 12- H W 3+ 4+ 11 12 14 34- 21 22 24 2+ 1+ 12- 3+ 4+ 11 12 14 34- 21 22 24 2+ Technical data Input Rated input voltage / DC input voltage range Input current Output Rated output voltage / Output voltage Rated (nominal) output current @ UNom Continous output current @ 24 V DC Voltage monitoring / Floating contact Switching thresholds 24 V DC / 18…30 V DC 2 x 10 A or 1 x 20 A 24 V DC / 18…30 V DC 2 x 20 A or 1 x 40 A 24 V DC ± 1 % / Input voltage - 0.7 V 20 A @ 60 °C 24 A @ 45 °C, 22.5 A @ 55 °C, 15 A @ 70 °C Yes, In both inputs / Yes 21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for Power Fail 24 V DC ± 1 % / Input voltage - 0.7 V 40 A @ 60 °C 48 A @ 45 °C, 45 A @ 55 °C, 30 A @ 70 °C Yes, In both inputs / Yes 21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for Power Fail > 97% @ 24 V input voltage 130 / 34 / 150 mm / 0.3 kg -25 °C...+70 °C / -40 °C...+85 °C 5...95 %, no condensation IP 20 / III, with no ground connection, for SELV / 2 0.5 kV Input/output housing > 500,000 h acc. to IEC 1709 (SN29500 Horizontal on TS35 mounting rail,w. 50 mm clearance at top/bottom for air circulation. Can be mount side by side w. no space in between. > 97% @ 24 V input voltage 130 / 60 / 150 mm / 0.6 kg -25 °C...+70 °C / -40 °C...+85 °C 5...95 %, no condensation IP 20 / III, with no ground connection, for SELV / 2 0.5 kV Input/output housing > 500,000 h acc. to IEC 1709 (SN29500 Horizontal on TS35 mounting rail,w. 50 mm clearance at top/bottom for air circulation. Can be mount side by side w. no space in between. Class B EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted) Class B EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted) Resistance to vibration / Shock Electrical safety (applied standards) Electrical machine equipment For use with electronic equipment Safety extra-low voltage Approvals Approvals 1 g according to EN50178 / 15 g In all directions 1 g according to EN50178 / 15 g In all directions Acc. to EN60204 Acc. to EN50178 / VDE0160 SELV acc. to EN60950, PLEV acc. to EN60204 Acc. to EN60204 Acc. to EN50178 / VDE0160 SELV acc. to EN60950, PLEV acc. to EN60204 cCSAus; cULus; GL; GOSTME25 cCSAus; cULus; GL; GOSTME25 Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil min/max Note Input Screw connection 4 (1+, 2+, 1-, 2-) 0.5 / 6 0.5 / 2.5 26 / 12 General data Degree of efficiency Height x width x depth / Weight Ambient temperature (operational) / Storage temperature Humidity Protection degree / Class of protection / Pollution severity Insulation voltage MTBF Mounting position, installation notice EMC / shock / vibration Noise emission acc. to EN55022 Interference immunity test acc. to mm² mm² Output Screw connection 4 (3 +, 4 +, 3 -, 4 -) 0.5 / 6 0.5 / 2.5 26 / 12 Input Screw connection 4 (1+, 2+, 1-, 2-) 0.5 / 16 2.5 / 10 22 / 6 Output Screw connection 4 (3 +, 4 +, 3 -, 4 -) 0.5 / 16 2.5 / 10 22 / 6 Ordering data Plastic clip-on foot Metal clip-on foot Type CP M DM20 CP M DM20 Qty. 1 1 Order No. 1222210000 1222210010 Type CP M DM40 CP M DM40 Qty. 1 1 Order No. 1222220000 1222220010 Note Accessories Note A.10 1366860000 – 2013 PRO-M: diode, capacity and relay modules Switch-mode power supplies connectPower PRO-M CP M RM24 A red + black – 11 H 12 14 D W Technical data Input Rated input voltage DC input voltage range Output Voltage monitoring Switching thresholds 24 V DC 18…30 V DC Yes 21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for Power Fail max. 250 V AC / 1 A, Relay Floating output General data Height x width x depth Weight Ambient temperature (operational) / Storage temperature Humidity Protection degree Class of protection Pollution severity Insulation voltage MTBF Mounting position, installation notice 28 / 33 / 22 mm 75 kg -25 °C...+70 °C / -40 °C...+85 °C 5...95 %, no condensation IP 20 III, with no ground connection, for SELV 2 0.5 kV Input/output housing > 500,000 h acc. to IEC 1709 (SN29500 Plugged in to the front of the PRO-M power supply EMC / shock / vibration Noise emission acc. to EN55022 Interference immunity test acc. to Class B EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)|EN 61000-4-11 (dips) 1 g according to EN50178 / 15 g In all directions Resistance to vibration / Shock Electrical safety (applied standards) Electrical machine equipment For use with electronic equipment Safety extra-low voltage Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil min/max Note Acc. to EN60204 Acc. to EN50178 / VDE0160 SELV acc. to EN60950, PLEV acc. to EN60204 cURus; GL; GOSTME25 Input PUSH IN mm² mm² Output PUSH IN 3 (CO contacts) 0.2 / 1.5 0.2 / 1.5 24 / 16 Ordering data Type CP M RM24 Qty. 1 Order No. 1222230000 Note Accessories Note 1366860000 – 2013 A.11 Switch-mode power supplies connectPower PRO-M PRO-M: diode, capacity and relay modules CP M CAP Pulse triggering for cable circuit breakers: with the Weidmüller capacitance module The following conditions apply to the table entries: • Ambient temperature of 20 °C • Inner resistance of the circuit breakers is taken into account • Half of the rated current flows to a neighbouring circuit before the short circuit is formed • DC-compatible circuit breakers: Siemens 5SY series 1+ 2+ + 11 12 14 H 12- W Distance in m Technical data Fuse tripping Input Rated input voltage / DC input voltage range Output Peak current output / Recovery time for the capacitor Switching thresholds 24 V DC / 18…30 V DC Depending on the load (typically 40 A for 1 ms) / Approx. 1 sec. 21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for Power Fail Yes Floating contact General data Height x width x depth / Weight Ambient temperature (operational) / Storage temperature Humidity Protection degree / Class of protection / Pollution severity Insulation voltage MTBF Mounting position, installation notice 130 / 34 / 150 mm / 0.4 kg -25 °C...+70 °C / -40 °C...+85 °C 5...95 %, no condensation IP 20 / III, with no ground connection, for SELV / 2 0.5 kV Input/output housing > 500,000 h acc. to IEC 1709 (SN29500 Horizontal on TS35 mounting rail,w. 50 mm clearance at top/bottom for air circulation. Can be mount side by side w. no space in between. EMC / shock / vibration Noise emission acc. to EN55022 Interference immunity test acc. to Class B EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN 61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)|EN 61000-4-11 (dips) 1 g according to EN50178 / 15 g In all directions Resistance to vibration / Shock Electrical safety (applied standards) Electrical machine equipment For use with electronic equipment Safety extra-low voltage Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil min/max Note cULus; GL; GOSTME25 mm² mm² Conductor cross section 0.75 mm2 1.0 mm2 1.5 mm2 2.5 mm2 4 mm2 6 mm2 0.75 mm2 1.0 mm2 1.5 mm2 2.5 mm2 4 mm2 6 mm2 0.75 mm2 1.0 mm2 1.5 mm2 2.5 mm2 4 mm2 6 mm2 0.75 mm2 1.0 mm2 1.5 mm2 2.5 mm2 4 mm2 6 mm2 Acc. to EN60204 Acc. to EN50178 / VDE0160 SELV acc. to EN60950, PLEV acc. to EN60204 Input Screw connection 4 (++--) 0.5 / 6 0.5 / 4 26 / 12 Load D Power supply + CAP module A B6 10 m 14 m 20 m 30 m 50 m B10 6 m 9 m 15 m 24 m B16 4m 6m 10 m 16 m C2 11 m 14 m 21 m 34 m C6 3m 3.5 m 5.5 m 9m 14 m C4 6 m 8 m 12 m 19 m 32 m C10 2 m 3 m 5 m 8 m 12 m Output Screw connection 3 (CO contacts) 0.5 / 6 0.5 / 2.5 26 / 12 For low-impedance connections we recommend 2.5 mm². Ordering data Plastic clip-on foot Metal clip-on foot Type CP M CAP CP M CAP Qty. 1 1 Order No. 1222240000 1222240010 Note Accessories Note A.12 1366860000 – 2013 A 1366860000 – 2013 A.13 Switch-mode power supplies Switch-mode power supplies connectPower PRO-M A PRO-M: Application solution for wind power Switched-mode power supply with wide-range input Application solution for wind power: •80 ... 430 V DC input •Alarm contact •Metal snap-on foot % { \u Technical data General technical data Output characteristic curve / current limit Earth discharge current Ambient temperature (operational) / Storage temperature Max. permitted humidity (operational) Degree of protection Class of protection Pollution degree Insulation voltage MTBF Protection against reverse voltages from the load Can be connected in parallel Housing version Signal indication Mounting position, installation notice Voltage derating 110 Pout [% Pn] 190 90 80 70 60 50 40 80 120 160 200 240 280 320 360 400 440 DC Input [V] Temperature derating 130 120 EMC / shock / vibration Noise emission acc. to EN55022 Noise immunity tests acc. to Pout [% Pn] 110 100 90 80 70 60 20 30 40 50 60 Ambient temperature [°C] A.14 70 80 Limiting of mains voltage harmonic currents Resistance against vibration and shock Electrical safety (applied standards) Electrical equipment of machines Safety transformers for switched-mode power units Safety transformers for switched-mode power units Safety extra low voltage Protective separation / protection against electrical shock Protection against dangerous shock currents IU / > 120 % IN < 3.5 mA –25 °C … +70 °C / –40 °C … +85 °C 5 %…95 % RH IP20 I, with PE connection 2 3 kV AC 1 min. / 2 kV AC 1 min. / 0.5 kV AC 1 min. > 500,000 h according to IEC 1709 (SN29500) 30…35 V DC Yes, without diode module Metal, corrosion resistant Operations, green/red LED Horizontal on TS35 mounting rail, with 50 mm of clearance at top and bottom for air circulation. Can be mounted side by side with no space in between. Suitable for installation in rotating systems. Class B EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields), EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN610004-6 (conducted), EN61000-4-11 (Dips) according to EN61000-3-2 according to EN50178, Shock: 5 g in all directions according to EN60204 according to EN61558-2-17 according to EN50178 / VDE0160 SELV according to EN60950, PELV according to EN60204 VDE0100-410 / according to DIN57100-410 according to VDE0106-101 1366860000 – 2013 PRO-M: application solutions for wind power Switch-mode power supplies connectPower PRO-M CP M SNT 250 W 24 V 10 A UW A D L (+) N (–) H AC PE + + – – 11 14 DC U << Bei DC-Anschluss auf Polarität achten W Technical data Input Rated input voltage / Input voltage range AC 100...240 V AC (wide-range input) / 85…264 V AC (Derating @ 100 V AC) 47...63 Hz 80…430 V DC 1.2 A @ 230 V AC / 2.4 A @ 115 V AC 0.8 A @ 370 V DC / 2.3 A @ 120 V DC Yes 4 A / DI, safety fuse 10 A, Char. B, circuit breaker 3...4 A, Char. C, circuit breaker Frequency range AC DC input voltage range AC current consumption DC current consumption Input fuse (internal) Recommended back-up fuse Output Rated output voltage Output voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC General data Degree of efficiency Power factor (approx.) AC failure bridging time @ INom Height x width x depth / Weight Additional equipment Status indicator Relay on/off Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil min/max Note 24 V DC ± 1 % 22.5...29.5 V DC (adjustable via potentiometer on front) < 50 mVSS @ 24 V DC, IN 10 A @ 60 °C 12 A @ 45 °C, 10.7 A @ 55 °C, 7.5 A @ 70 °C 90 % @ 230 V AC / 87 % @ 115 V AC > 0.99 @ 230 V AC / > 0.97 @ 115 V AC > 20 ms @ 230 V AC / > 20 ms @ 115 V AC 130 / 60 / 155 mm / 1.2 Kg Green LED, red LED Output voltage > 21.6 V / < 20.4 V cULus; cURus; GL; GOSTME25 mm² mm² Input Screw connection 3 for L/N/PE 0.5 / 6 0.5 / 2.5 26 / 12 Output Screw connection 6 (+,+,-,-,COM,NO) 0.5 / 6 0.5 / 2.5 26 / 12 Ordering data Type CP M SNT 250W 24V 10AUW Qty. 1 Order No. 1165480010 Note Accessories Note 1366860000 – 2013 A.15 Switch-mode power supplies connectPower PRO-H connectPower PRO-H A % { \ | CB Scheme Technical data L (+) N (–) AC General technical data Current limiting Ambient temp. operating / storage temperature Max. perm. air humidity (operation) Degree of protection Class of protection Pollution degree Insulation voltage input/output MTBF according to IEC 61709 + DC PE – > 100 % IN -25…+70 °C -25 °C…+85 °C 95 % RH IP20 I, with PE connection 2 4 kV I/O 2 kV I/earth 0.5 kV O/earth > 1.8 Mio. h CP T … 70/90 W > 1.2 Mio. h CP T … 140 W CP T … 180/360/600 W > 0.9 Mio. h 16 V DC / 35 V DC / 63 V DC yes, without diode module metal, corrosion resistant Thermal protection, autom. restart Unlimited, autom. restart Dual LED Operational: Green LED; Error: Red LED Horizontal on TS35 mounting rail, with 80 mm space at top and bottom. Side by side mounting with 50 mm clearance. Protection against reverse voltages from the load Parallel connection option Housing version Overload protection Short circuit protection Indication Mounting position, installation notice Signal indication Power Good Signal Trigger point 12 V version 9…11 V DC 24 V version 18...22 V DC 48 V version 36...44 V DC NO contact 30 V DC/1.0 A max. for 12/24 V DC modules 48 V DC/ 0.5 A max. for 36/48 V DC modules 70 W 11 V DC ± 1 V DC / 20 mA max. 140 W 11 V DC ± 1 V DC / 40 mA max. 90 W 22 V DC ± 2 V DC / 10 mA max. 22 V DC± 2 V DC / 20 mA max. 180/360/600 W 24 V DC 180/360/600 W 48 V DC 44 V DC± 4 V DC / 15 mA max. Potential free, floating signal contact Active output signal Max. limiting average on state current [A] Type\Temp. 1 ph 12 V / 6 A 1 ph 12 V / 12 A 1 ph 24 V / 3.8 A 1 ph 24 V / 7.5 A 1 ph 24 V / 15 A 1 ph 24 V / 25 A 1 ph 36 V / 16.5 A 1 ph 48 V / 2 A 1 ph 48 V / 4 A 1 ph 48 V / 7.5 A 1 ph 48 V / 12.5 A 1-2 ph 24 V / 7.5 A 1-2 ph 24 V / 15 A 1-2 ph 24 V / 25 A 40 °C 6.0 12.0 3.8 7.5 15.0 25.0 16.5 2.0 4.0 7.5 12.5 7.5 15.0 25.0 50 °C 5.7 9.5 3.1 6.3 12.5 22.5 15.0 1.6 3.3 6.3 11.3 6.3 12.5 22.5 60 °C 5.4 7.0 2.5 5.0 10.0 20.0 13.3 1.3 2.5 5.0 10.0 5.0 10.0 20.0 70 °C 4.5 3.7 1.7 3.3 6.7 13.3 9.0 0.8 1.7 3.3 7.5 3.3 6.7 13.3 EMC / shock / vibration Noise emission acc. to EN55022 Noise immunity tests acc. to Class B EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields), EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN610004-6 (conducted), EN61000-4-11 (Dips) according to EN61000-3-2 3 axes, sinus, 10 – 55 Hz, 1 g, 1 oct./min. 3 axes, 15 g, half sinus, 11 ms Limiting of mains voltage harmonic currents Vibration IEC 60068-2-6 Shock IEC 60068-2-27 Electrical safety (applied standards) Electrical equipment of machines Safety transformers for switched-mode power units Machinery with electronic equipment Safety extra low voltage according to EN60204 according to EN61558-2-4 according to EN50178 SELV according to EN60950 CP T SNT... 100 100 90 600 W 80 70 90 W 180 W 360 W 60 50 40 -25 40 50 Temperature [°C] A.16 70 W 140 W 60 70 Output Power [% Pmax] Output Power [% Pmax] 90 80 70 60 50 40 85 90 100 110 115 132 187 230 264 Input Voltage [VAC] 1366860000 – 2013 connectPower PRO-H CP T SNT 70 W 12 V 6 A Switch-mode power supplies connectPower PRO-H CP T SNT 140 W 12 V 12 A A Technical data Input Rated input voltage Input voltage range AC Frequency range AC AC current consumption Input fuse (internal) / making current Recommended back-up fuse Output Rated output voltage Output voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC General data Degree of efficiency AC failure bridging time @ INom Parallel connection option Height x width x depth Weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Stripping length, rated connection Wire cross-section, AWG/kcmil min/max Note mm² 100...240 V AC (wide-range input) 85...264 V AC 47...63 Hz 1 A @ 230 V AC, 2 A @ 115 V AC 4 A / < 20 A (230 V AC) 6…16 A, char. B, circuit breaker 100…240 V AC (auto-select) 85…132 V AC, 187…264 V AC 47...63 Hz 1.4 A @ 230 V AC, 2.5 A @ 115 V AC 4 A / < 20 A (230 V AC) 6…16 A, char. B, circuit breaker 12 V DC ± 1 % 12...14 V DC (adjustable via potentiometer on front) 100 mVSS @ 12 V DC, Inom 6 A @ 40 °C 6 A @ 40 °C, 5.4 A @ 60 °C, 4.5 A @ 70 °C 12 V DC ± 1 % 12...14 V DC (adjustable via potentiometer on front) 100 mVSS @ 12 V DC, Inom 12 A @ 40 °C 12 A @ 40 °C, 7 A @ 60 °C, 3.7 A @ 70 °C typ. 82 % @ 230 V AC min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC yes, max. 5 110 / 35 / 110 mm 0.5 kg typ. 85 % @ 230 V AC min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC yes, max. 5 110 / 54 / 110 mm 0.7 kg BVATEX; CE; CSA; cURus; GOSTME25; UL BVATEX; CE; CSA; cURus; GOSTME25; UL Input Screw connection 3 for L/N/PE 0.5 / 2.5 7 mm 24 / 12 Input Screw connection 3 for L/N/PE 0.5 / 2.5 7 mm 24 / 12 Output Screw connection 2 (+ / -) 1 / 2.5 Output Screw connection 7 (+ / - / Signal) 1 / 2.5 Ordering data Type CP T SNT 70W 12V 6A Qty. 1 Order No. 1105430000 Type CP T SNT 140W 12V 12A Qty. 1 Order No. 1105440000 Note Accessories Note 1366860000 – 2013 A.17 Switch-mode power supplies connectPower PRO-H connectPower PRO-H CP T SNT 90 W 24 V 3,8 A CP T SNT 90 W 24 V 3,8 A CL2 Class 2, UL1310 A Technical data Input Rated input voltage Input voltage range AC Frequency range AC AC current consumption Input fuse (internal) / making current Recommended back-up fuse Output Rated output voltage Output voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC General data Degree of efficiency AC failure bridging time @ INom Parallel connection option Height x width x depth Weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Stripping length, rated connection Wire cross-section, AWG/kcmil min/max Note 100...240 V AC (wide-range input) 85...264 V AC 47...63 Hz 1 A @ 230 V AC, 2.1 A @ 115 V AC 4 A / < 20 A (230 V AC) 6…16 A, char. B, circuit breaker 100...240 V AC (wide-range input) 85...264 V AC 47...63 Hz 1 A @ 230 V AC, 2.1 A @ 115 V AC 4 A / < 20 A (230 V AC) 6…16 A, char. B, circuit breaker 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mVPP @ 24 V DC, Inenn 3.8 A @ 40 °C 3.8 A @ 40 °C, 2.5 A @ 60 °C, 1.7 A @ 70 °C 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mVPP @ 24 V DC, Inenn 3.8 A @ 40 °C 3.8 A @ 40 °C, 2.5 A @ 60 °C, 1.7 A @ 70 °C typ. 85 % @ 230 V AC min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC yes, max. 5 110 / 35 / 110 mm 0.5 kg typ. 85 % @ 230 V AC min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC yes, max. 5 110 / 35 / 110 mm 0.5 kg BVATEX; CE; CSA; cURus; GOSTME25; UL mm² Input Screw connection 3 for L/N/PE 0.5 / 2.5 7 mm 24 / 12 Output Screw connection 2 (+ / -) 1 / 2.5 Input Screw connection 3 for L/N/PE 0.5 / 2.5 7 mm 24 / 12 Output Screw connection 2 (+ / -) 1 / 2.5 Ordering data Type CP T SNT 90W 24V 3,8A Qty. 1 Order No. 1105790000 Type CP T SNT 90W 24V3,8ACL2 Qty. 1 Order No. 1194410000 Note Accessories Note A.18 1366860000 – 2013 connectPower PRO-H CP T SNT 180 W 24 V 7,5 A Switch-mode power supplies connectPower PRO-H CP T SNT 360 W 24 V 15 A A Technical data Input Rated input voltage Input voltage range AC Frequency range AC AC current consumption Input fuse (internal) / making current Recommended back-up fuse Output Rated output voltage Output voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC General data Degree of efficiency AC failure bridging time @ INom Parallel connection option Height x width x depth Weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Stripping length, rated connection Wire cross-section, AWG/kcmil min/max Note mm² 100…240 V AC (auto-select) 85…132 V AC, 187…264 V AC 47...63 Hz 1.4 A @ 230 V AC, 2.5 A @ 115 V AC 4 A / < 20 A (230 V AC) 6…16 A, char. B, circuit breaker 100…240 V AC (auto-select) 85…132 V AC, 187…264 V AC 47...63 Hz 2.5 A @ 230 V AC, 5 A @ 115 V AC 6.3 A / < 25 A (230 V AC) 10…16 A, char. B, circuit breaker 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mVPP @ 24 V DC, Inenn 7.5 A @ 40 °C 7.5 A @ 40 °C, 5 A @ 60 °C, 3.3 A @ 70 °C 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mVPP @ 24 V DC, Inenn 15 A @ 40 °C 15 A @ 40 °C, 10 A @ 60 °C, 6.7 A @ 70 °C typ. 88 % @ 230 V AC min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC yes, max. 5 110 / 54 / 110 mm 0.7 kg typ. 87 % @ 230 V AC min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC yes, max. 5 110 / 80 / 110 mm 1.1 kg BVATEX; CE; CSA; cURus; GOSTME25; UL BVATEX; CE; CSA; cURus; GOSTME25; UL Input Screw connection 3 for L/N/PE 0.5 / 2.5 7 mm 24 / 12 Input Screw connection 3 for L/N/PE 0.5 / 2.5 7 mm 24 / 12 Output Screw connection 7 (+ / - / Signal) 1 / 2.5 Output Screw connection 7 (+ / - / Signal) 1 / 2.5 Ordering data Type CP T SNT 180W 24V 7,5A Qty. 1 Order No. 1105810000 Type CP T SNT 360W 24V 15A Qty. 1 Order No. 1105820000 Note Accessories Note 1366860000 – 2013 A.19 Switch-mode power supplies connectPower PRO-H connectPower PRO-H CP T SNT 600 W 24 V 25 A CP T SNT 600 W 36 V 16,5 A A Technical data Input Rated input voltage Input voltage range AC Frequency range AC AC current consumption Input fuse (internal) / making current Recommended back-up fuse Output Rated output voltage Outpu voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC General data Degree of efficiency AC failure bridging time @ INom Parallel connection option Height x width x depth Weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Stripping length, rated connection Wire cross-section, AWG/kcmil min/max Note 100…240 V AC (auto-select) 85…132 V AC, 187…264 V AC 47...63 Hz 5 A @ 230 V AC, 10 A @ 115 V AC 12 A / < 30 A (230 V AC) 16…25 A, char. B, circuit breaker 100…240 V AC (auto-select) 85…132 V AC, 187…264 V AC 47...63 Hz 1 A @ 230 V AC, 2 A @ 115 V AC 12 A / < 30 A (230 V AC) 16…25 A, char. B, circuit breaker 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mVPP @ 24 V DC, Inenn 25 A @ 40 °C 25 A @ 40 °C, 20 A @ 60 °C, 13.3 A @ 70 °C 36 V DC ± 1 % 36...42 V DC (adjustable via potentiometer on front) 100 mVSS @ 36 V DC, Inom 16.5 A @ 40 °C 16.5 A @ 40 °C, 13.3 A @ 60 °C, 9 A @ 70 °C typ. 89 % @ 230 V AC min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC yes, max. 5 125 / 165 / 125 mm 2.8 kg typ. 87 % @ 230 V AC min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC yes, max. 5 125 / 165 / 125 mm 2.8 kg BVATEX; CE; CSA; cURus; GOSTME25; UL mm² Input Screw connection 3 for L/N/PE 1/4 7 mm 18 / 10 Output Screw connection 7 (+ / - / Signal) 1 / 2.5 Input Screw connection 3 for L/N/PE 1/4 7 mm 18 / 10 Output Screw connection 7 (+ / - / Signal) 1 / 2.5 Ordering data Type CP T SNT 600W 24V 25A Qty. 1 Order No. 1105840000 Type CP T SNT 600W 36V 16,5A Qty. 1 Order No. 1194430000 Note Accessories Note A.20 1366860000 – 2013 connectPower PRO-H CP T SNT 90 W 48 V 2 A Switch-mode power supplies connectPower PRO-H CP T SNT 180 W 48 V 4 A A Technical data Input Rated input voltage Input voltage range AC Frequency range AC AC current consumption Input fuse (internal) / making current Recommended back-up fuse Output Rated output voltage Output voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC General data Degree of efficiency AC failure bridging time @ INom Parallel connection option Height x width x depth Weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Stripping length, rated connection Wire cross-section, AWG/kcmil min/max Note 100...240 V AC (wide-range input) 85...264 V AC 47...63 Hz 1 A @ 230 V AC, 2.1 A @ 115 V AC 4 A / < 20 A (230 V AC) 6…16 A, char. B, circuit breaker 100…240 V AC (auto-select) 85…132 V AC, 187…264 V AC 47...63 Hz 1.4 A @ 230 V AC, 2.5 A @ 115 V AC 4 A / < 25 A (230 V AC) 6…16 A, char. B, circuit breaker 48 V DC ± 1 % 48...56 V DC (adjustable via potentiometer on front) 100 mVSS @ 48 V DC, INenn 2 A @ 40 °C 2 A @ 40 °C, 1.3 A @ 60 °C, 0.8 A @ 70 °C 48 V DC ± 1 % 48...56 V DC (adjustable via potentiometer on front) 100 mVSS @ 48 V DC, INenn 4 A @ 40 °C 4 A @ 40 °C, 2.5 A @ 60 °C, 1.7 A @ 70 °C typ. 87 % @ 230 V AC min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC yes, max. 5 110 / 35 / 110 mm 0.5 kg typ. 90 % @ 230 V AC min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC yes, max. 5 110 / 54 / 110 mm 0.7 kg BVATEX; CSA; cURus; GOSTME25; UL mm² Input Screw connection 3 for L/N/PE 0.5 / 2.5 7 mm 24 / 12 Output Screw connection 2 (+ / -) 1 / 2.5 Input Screw connection 3 for L/N/PE 0.5 / 2.5 7 mm 24 / 12 Output Screw connection 7 (+ / - / Signal) 1 / 2.5 Ordering data Type CP T SNT 90W 48V 2A Qty. 1 Order No. 1194420000 Type CP T SNT 180W 48V 4A Qty. 1 Order No. 1105850000 Note Accessories Note 1366860000 – 2013 A.21 Switch-mode power supplies connectPower PRO-H connectPower PRO-H CP T SNT 360 W 48V 7,5 A CP T SNT 600 W 48 V 12,5 A A Technical data Input Rated input voltage Input voltage range AC Frequency range AC AC current consumption Input fuse (internal) / making current Recommended back-up fuse Output Rated output voltage Output voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC General data Degree of efficiency AC failure bridging time @ INom Parallel connection option Height x width x depth Weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Stripping length, rated connection Wire cross-section, AWG/kcmil min/max Note mm² 100…240 V AC (auto-select) 85…132 V AC, 187…264 V AC 47...63 Hz 2.5 A @ 230 V AC, 5 A @ 115 V AC 6.3 A / < 25 A (230 V AC) 10…16 A, char. B, circuit breaker 100…240 V AC (auto-select) 85…132 V AC, 187…264 V AC 47...63 Hz 5 A @ 230 V AC, 10 A @ 115 V AC 12 A / < 30 A (230 V AC) 16…25 A, char. B, circuit breaker 48 V DC ± 1 % 48...56 V DC (adjustable via potentiometer on front) 100 mVSS @ 48 V DC, INenn 7.5 A @ 40 °C 7.5 A @ 40 °C, 5 A @ 60 °C, 3.3 A @ 70 °C 48 V DC ± 1 % 48...56 V DC (adjustable via potentiometer on front) 100 mVSS @ 48 V DC, INenn 12.5 A @ 40 °C 12.5 A @ 40 °C, 10 A @ 60 °C, 7.5 A @ 70 °C typ. 89 % @ 230 V AC min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC yes, max. 5 110 / 80 / 110 mm 1.1 kg typ. 91 % @ 230 V AC min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC yes, max. 5 125 / 165 / 125 mm 2.8 kg BVATEX; CSA; cURus; GOSTME25; UL BVATEX; CSA; cURus; GOSTME25; UL Input Screw connection 3 for L/N/PE 0.5 / 2.5 7 mm 24 / 12 Input Screw connection 3 for L/N/PE 1/4 7 mm 18 / 10 Output Screw connection 7 (+ / - / Signal) 1 / 2.5 Output Screw connection 7 (+ / - / Signal) 1 / 2.5 Ordering data Type CP T SNT 360W 48V 7,5A Qty. 1 Order No. 1105860000 Type CP T SNT 600W 48V 12,5A Qty. 1 Order No. 1105870000 Note Accessories Note A.22 1366860000 – 2013 connectPower PRO-H CP T SNT2 180 W 24 V 7,5 A Switch-mode power supplies connectPower PRO-H CP T SNT2 360 W 24 V 15 A A Technical data Input Rated input voltage Input voltage range AC Frequency range AC AC current consumption Input fuse (internal) / making current Recommended back-up fuse Output Rated output voltage Output voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC General data Degree of efficiency AC failure bridging time @ INom Parallel connection option Height x width x depth Weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Stripping length, rated connection Wire cross-section, AWG/kcmil min/max Note 100…500 V AC (switchable) 85…132 V AC, 187…550 V AC 50 / 60 Hz 100…500 V AC (switchable) 85…132 V AC, 187…550 V AC 50 / 60 Hz / < 23 A @ 230 V AC mm² / < 23 A @ 230 V AC 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mVPP @ 24 V DC, Inenn 7.5 A @ 40 °C 7.5 A @ 40 °C, 5 A @ 60 °C, 3.3 A @ 70 °C 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mVPP @ 24 V DC, Inenn 15 A @ 40 °C 15 A @ 40 °C, 10 A @ 60 °C, 6.7 A @ 70 °C typ. 88 % typ. 88 % Yes 110 / 54 / 110 mm 0.7 kg Yes 125 / 80 / 125 mm 1.1 kg Input Screw connection 3 for L/N/PE 1/4 7 mm 18 / 10 Output Screw connection 2/4 12 / 10 Input Screw connection 3 for L/N/PE 1/4 7 mm 18 / 10 Output Screw connection 2/4 12 / 10 Ordering data Type CP T SNT2 180 W 24 V 7,5 A Qty. 1 Order No. 1194480000 Type CP T SNT2 360 W 24 V 15 A Qty. 1 Order No. 1194490000 Note Accessories Note 1366860000 – 2013 A.23 Switch-mode power supplies connectPower PRO-H connectPower PRO-H CP T SNT2 600 W 24 V 25 A A Technical data Input Rated input voltage Input voltage range AC Frequency range AC AC current consumption Input fuse (internal) / making current Recommended back-up fuse Output Rated output voltage Output voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC General data Degree of efficiency AC failure bridging time @ INom Parallel connection option Height x width x depth Weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Stripping length, rated connection Wire cross-section, AWG/kcmil min/max Note 100…500 V AC (switchable) 85…132 V AC, 187…550 V AC 50 / 60 Hz / < 50 A @ 230 V AC 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mVPP @ 24 V DC, Inenn 25 A @ 40 °C 25 A @ 40 °C, 20 A @ 40 °C, 13.3 A @ 70 °C typ. 88 % min. 20 ms Yes 125 / 190 / 125 mm 3 kg mm² Input Screw connection 3 for L/N/PE 1/4 7 mm 18 / 10 Output Screw connection 5 (++ / ---) 2/4 12 / 10 Ordering data Type CP T SNT2 600 W 24 V 25 A Qty. 1 Order No. 1194310000 Note Accessories Note A.24 1366860000 – 2013 connectPower PRO-H CP T RM 10 Switch-mode power supplies connectPower PRO-H CP T RM 20 A Technical data Input Rated input voltage Input voltage range AC Frequency range AC AC current consumption Input fuse (internal) / making current Recommended back-up fuse Output Rated output voltage Output voltage Residual ripple, breaking spikes Rated (nominal) output current @ UNom Continous output current @ 24 V DC General data Degree of efficiency AC failure bridging time @ INom Parallel connection option Height x width x depth Weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Stripping length, rated connection Wire cross-section, AWG/kcmil min/max Note mm² 24 V DC 24 V DC 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mVPP @ 24 V DC, Inenn 15 A @ 40 °C 24 V DC ± 1 % 24...28 V DC (adjustable via potentiometer on front) 100 mVPP @ 24 V DC, Inenn 25 A @ 40 °C 110 / 35 / 110 mm 0.4 kg 110 / 54 / 110 mm 0.45 kg CSA; cURus; GOSTME25 CE; CSA; cURus; GOSTME25 Input Output Input Output 4 (++--) 1/4 mm 18 / 10 4 (++ / --) 2/4 4 (++--) 1/4 mm 18 / 10 4 (++ / --) 2/4 12 / 10 12 / 10 Ordering data Type CP T RM 10 Qty. 1 Order No. 1105880000 Type CP T RM 20 Qty. 1 Order No. 1105890000 Note Accessories Note 1366860000 – 2013 A.25 38.5 (1.52) Output Inputs ON DC 24V / 25 A Inputs ON DC IN 1 (0.98) 5.0 (0.20) 14.5 (0.57) CP T RM 20 35.0 (1.38) 54.0 (2.13) 38.5 (1.52) 110.0 (4.33) DC OK DC ON DC ON 80.0 (3.15) L 25.0 (0.98) 5.0 5.0 (0.20) (0.20) 5.0 110.0 (4.33) 80.0 (3.15) 110.0 (4.33) 25.0 (0.20) PE N L (0.98) DC OK O/P ADJ. O/P ADJ. PE N 110.0 (4.33) 38.5 (1.52) CP T RM 10 DC IN 2 25.0 (0.20) 5.0 (0.98) 5.0 24 – 27 V - + 25.0 (0.20) 110.0 (4.33) 24 – 27 V DC IN 1 DC IN 2 110.0 (4.33) 80.0 (3.15) - - + + - + 54.0 (2.13) 110.0 (4.33) 38.5 (1.52) 35.0 (1.38) 80.0 (3.15) A PRO-H Dimensional drawings 110.0 (4.33) Switch-mode power supplies connectPower PRO-H 14.5 (0.57) P/ S CP T SNT 70 W / 90 W A.26 Remote S P P S Remote P/ S CP T SNT 180 W / 140 W 1366860000 – 2013 Switch-mode power supplies connectPower PRO-H PRO-H Dimensional drawings 80.0 (3.15) 45.0(1.77) 125.0 (4.92) DC OK DC ON O/P ADJ. P/ S Remote A 86.5(3.41) 125.0 (4.92) P S PE N L 25.0 25.0 (0.98) 46.0 17.0 25.0 21.0 (4.84) (0.83) (0.67) 165.0 (6.50) 25.0 125.0 (4.92) (0.98) PE N L DC OK DC ON O/ P ADJ. 86.5 (3.41) 125.0 (4.92) 45.0 (1.77) 5.0 (0.20) (1.81) (0.98) (0.98) 123.0 Remote P S P/ S CP T SNT 360 W / 480 W 1366860000 – 2013 CP T SNT 600 W / 960 W A.27 Switch-mode power supplies ECOLINE connectPower single-phase CP SNT 70 W 24 V 3 A H A W D Vin AC L AC/DC N PWM EMC Filter Rectifier + Flyback Converter Output Recctifier & Filter V out DC Output Current Check & Share current control Feedback DC OVP, OTP – 12 Signal Relay 11 14 Technical data 85...264 V AC / 110...370 V DC 2 A @ 100...240 V AC 50/ 60 Hz Fusible link 2.5 A (T) / 250 V Varistor 24...28 V DC (adjustable via potentiometer) 3A 72 W < 100 mVPP / bandwidth 20 MHz 105 %..130 % Iconst of max. output load; automatic reset 4 3.5 3 2.5 2 1.5 1 0.5 0 0 10 20 30 40 50 60 Ambient temperature (°C) 70 80 29...34 V 10 ms @ 115 V AC / 20 ms @ 230 V AC <2% Recommended with diode module 250 V AC (max. 30 V DC) / 1 A Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Status relay / CO contact Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output General data Ambient temperature Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Mounting position, installation notice Installation advice Weight Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note Current (A) Derating curve Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection 0.5 kV 1.5 kV 3 kV -10 °C+70 °C (Derating ab 55 °C) -20 °C...+85 °C 80% Green LED DIN EN 60950 (SELV) EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 horizontally, on terminal rail TS 35 Clearance: above/below ≥ 3 cm 0.55 kg CE; cULus; cURus; GL; GOSTME25 mm² Input/Output 2.5 / 0.13 / 4 125 / 55.5 / 110 mm For redundancy operation or to maintain the alert function, only operate with the diode module. Ordering data Screw connection Note Type CP SNT 70W 24V 3A Qty. 1 Order No. 8708660000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Accessories Note A.28 1366860000 – 2013 connectPower single-phase Switch-mode power supplies ECOLINE CP SNT 120 W 24 V 5 A H A W D V IN AC L AC/DC N PWM EMC & Filter Forward Converter Rectifier & Filter + PWM Controller DC – V OUT DC Out Rectifier & Filter Photocoupler Voltage feedback Photocoupler OVP Signal Relay 12 11 14 Technical data Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection 88...132 V AC/176...264 V AC selectable; 250...370 V DC 3 A @ 115 V AC / 2 A @ 230 V AC 50/ 60 Hz Fusible link 4 A (T) / 250 V Varistor 24...28 V DC (adjustable via potentiometer) 5A 120 W < 100 mVPP / bandwidth 20 MHz 105 %..130 % Iconst of max. output load; automatic reset 29...34 V 20 ms @ 115 V AC / 20 ms @ 230 V AC <2% Recommended with diode module 250 V AC (max. 30 V DC) / 1 A Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Status relay / CO contact Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output General data Ambient temperature Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Mounting position, installation notice Installation advice Weight Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 0.5 kV 1.5 kV 3 kV -10 °C+70 °C (Derating ab 55 °C) -20 °C...+85 °C 84% Green LED DIN EN 60950 (SELV) EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 horizontally, on terminal rail TS 35 Clearance: above/below ≥ 3 cm 0.65 kg CE; cULus; cURus; GL; GOSTME25 mm² Input/Output 2.5 / 0.13 / 4 125 / 65.5 / 110 mm For redundancy operation or to maintain the alert function, only operate with the diode module. Ordering data Screw connection Note Type CP SNT 120W 24V 5A Qty. 1 Order No. 8708670000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Accessories Note 1366860000 – 2013 A.29 connectPower single-phase CP SNT 250 W 24 V 10 A H A W D VIN AC L AC/DC N PWM EMC Input Rectifier & Filter + Output Rectifier & Filter Forward Converter VOUT DC PWM Control DC Photocoupler – Feedback Signal Relay 12 11 14 Technical data Derating curve Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection 88...132 V AC/176...264 V AC selectable; 250...370 V DC 3.6 A @ 115 V AC / 2 A @ 230 V AC 50/ 60 Hz Fusible link 5 A (T) / 250 V Varistor 24...28 V DC (adjustable via potentiometer) 0.1…10 A 240 W < 100 mVPP / bandwidth 20 MHz 105 %..130 % Iconst of max. output load; automatic reset 10 8 6 4 2 0 0 10 20 30 40 50 60 Ambient temperature (°C) 70 80 30...36 V 10 ms @ 115 V AC / 15 ms @ 230 V AC <2% Recommended with diode module 250 V AC (max. 30 V DC) / 1 A Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Status relay / CO contact Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output General data Ambient temperature Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Mounting position, installation notice Installation advice Weight Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 12 Current (A) Switch-mode power supplies ECOLINE 0.5 kV 1.5 kV 3 kV -10 °C+70 °C (Derating ab 55 °C) -20 °C...+85 °C 84% @ 230 V AC Green LED DIN EN 60950 (SELV) EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 horizontally, on terminal rail TS 35 Clearance: above/below ≥ 3 cm 1.6 kg CE; cULus; cURus; GL; GOSTME25 mm² Input/Output 4 / 0.13 / 6 125 / 125.5 / 110 mm For redundancy operation or to maintain the alert function, only operate with the diode module. Ordering data Screw connection Note Type CP SNT 250W 24V 10A Qty. 1 Order No. 8708680000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Accessories Note A.30 1366860000 – 2013 connectPower single-phase Switch-mode power supplies ECOLINE CP SNT 500 W 24 V 20 A H A W D VIN AC L AC/DC N PWM EMI Input Rectiefier & Filter Forward Converter Output Rectifier & Filter PWM Feedback VOUT DC + DC – Signal Relay 12 11 14 Technical data Derating curve 88...132 V AC/176...264 V AC selectable; 250...370 V DC 9 A @ 115 V AC / 6 A @ 230 V AC 50/ 60 Hz Fusible link 10 A (T) / 250 V Varistor 24...28 V DC (adjustable via potentiometer) 2...20 A @ 200...240 V AC; 2...16 A @ 100...120 V AC 480 W < 100 mVPP / bandwidth 20 MHz 105 %..130 % Iconst of max. output load; automatic reset 20 10 0 0 10 20 30 40 50 60 Ambient temperature (°C) 70 80 30...36 V 10 ms @ 115 V AC / 15 ms @ 230 V AC <2% Recommended with diode module 250 V AC (max. 30 V DC) / 1 A Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Status relay / CO contact Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output General data Ambient temperature Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Mounting position, installation notice Installation advice Weight Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 30 Current (A) Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection 0.5 kV 1.5 kV 3 kV -10 °C+70 °C (Derating ab 55 °C) -20 °C...+85 °C 86% Green LED DIN EN 60950 (SELV) EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 horizontally, on terminal rail TS 35 Clearance: above/below ≥ 3 cm 2 kg CE; cULus; cURus; GL; GOSTME25; TUEV mm² Input/Output 4 / 0.13 / 6 125 / 227.5 / 110 mm For redundancy operation or to maintain the alert function, only operate with diode module. Ordering data Screw connection Note Type CP SNT 500W 24V 20A Qty. 1 Order No. 8778870000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Accessories Note 1366860000 – 2013 A.31 connectPower single-phase CP SNT 1000 W 24 V 40 A H A W D V IN AC L AC/DC N PWM EMC & Filter Rectifier & Filter + Forward Converter PWM Controller DC – V OUT DC Out Rectifier & Filter Photocoupler Voltage feedback Photocoupler OVP Signal Relay 12 11 14 Technical data Derating curve Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection 85…264 V AC 12 A @ 115 V AC; 4.8 A @ 230 V AC 50/ 60 Hz Fusible link 15 A (T) / 250 V Varistor 40 24...28 V DC (adjustable via potentiometer) 40 A 960 W < 100 mVPP / bandwidth 20 MHz 105 %...125 % Iconst of max. output load; automatic reset 30 20 10 0 0 10 20 30 40 50 60 Ambient temperature (°C) 70 80 29...34 V 20 ms @ 115 V AC / 20 ms @ 230 V AC <2% Recommended with diode module 250 V AC (max. 30 V DC) / 1 A Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Status relay / CO contact Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output General data Ambient temperature Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Mounting position, installation notice Installation advice Weight Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 50 Current (A) Switch-mode power supplies ECOLINE 0.5 kV 1.5 kV 3 kV -10 °C+70 °C (Derating ab 55 °C) -20 °C...+85 °C 89% Green LED DIN EN 60950 (SELV) EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 horizontally, on terminal rail TS 35 Clearance: above/below ≥ 3 cm 4.4 kg CE; cURus; GOSTME25 mm² Input/Output 4 / 0.13 / 6 150 / 240 / 125 mm For redundancy operation or to maintain the alert function, only operate with diode module. Ordering data Screw connection Note Type CP SNT 1000W 24V 40A Qty. 1 Order No. 8862780000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Accessories Note A.32 1366860000 – 2013 connectPower 3-phase Switch-mode power supplies ECOLINE CP SNT3 120 W 24 V 5 A H A W V IN AC L1 AC L2 L3 PWM EMC & Filter Forward Converter Rectifier & Filter + PWM Controller DC – V OUT DC Out Rectifier & Filter Photocoupler Voltage feedback Photocoupler OVP Signal Relay 12 11 14 Technical data Derating curve Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection 3x400 V AC / 400...500 V AC ±15 % 0.8 A @ 400 V AC 47...63 Hz External via 3 circuit-breakers up to 6...16 A, char. C Varistor 5 24...28 V DC (adjustable via potentiometer) 5A 120 W < 100 mVPP / bandwidth 20 MHz 105 %..130 % Iconst of max. output load; automatic reset 4 3 2 1 0 0 10 20 30 40 50 60 Ambient temperature (°C) 70 80 29...34 V > 20 ms @ 400 V AC <2% Recommended with diode module 250 V AC (max. 30 V DC) / 1 A Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Status relay / CO contact Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output General data Ambient temperature Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Mounting position, installation notice Installation advice Weight Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 6 Current (A) D 0.5 kV 1.5 kV 3 kV -10 °C+70 °C (Derating ab 55 °C) -20 °C...+85 °C 85% @ 400 V AC Green LED DIN EN 60950 (SELV) EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 horizontally, on terminal rail TS 35 Clearance: above/below ≥ 3 cm 1.5 kg cURus; GOSTME25; UL mm² Input/Output 4 / 0.13 / 4 125 / 90 / 110 mm For redundancy operation or to maintain the alert function, only operate with the diode module. Ordering data Screw connection Note Type CP SNT3 120W 24V 5A Qty. 1 Order No. 8862730000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Accessories Note 1366860000 – 2013 A.33 connectPower 3-phase CP SNT3 250 W 24 V 10 A H A W D 3ph VIN AC L1 AC L2 L3 PWM VOUT DC AC/DC Converter + DC Output Voltage control Anti Surge Circuit – Output Current Check & Control R SENSE OCP Output Current Protection OTP/OVP Output Voltage Protection Signal Relay 12 11 14 Technical data Derating curve Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection 3x400 V AC / 400...500 V AC ±15 % 0.95 A @ 400 V AC 47...63 Hz External via 3 circuit-breakers up to 2…3 A, char. C Varistor 10 24...28 V DC (adjustable via potentiometer) 10 A 250 W < 100 mVPP / bandwidth 20 MHz 105 %..130 % Iconst of max. output load; automatic reset 8 6 4 2 0 0 10 20 30 40 50 60 Ambient temperature (°C) 70 80 29...34 V > 10 ms @ 400 V AC <2% Recommended with diode module 250 V AC (max. 30 V DC) / 1 A Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Status relay / CO contact Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output General data Ambient temperature Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Mounting position, installation notice Installation advice Weight Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 12 Current (A) Switch-mode power supplies ECOLINE 0.5 kV 1.5 kV 3 kV -10 °C+70 °C (Derating ab 55 °C) -20 °C...+85 °C 88% @ 400 V AC Green LED DIN EN 60950 (SELV) EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 horizontally, on terminal rail TS 35 Clearance: above/below ≥ 3 cm 1.5 kg CE; cULus; cURus; GL; GOSTME25 mm² Input/Output 4 / 0.13 / 6 125 / 125.5 / 110 mm For redundancy operation or to maintain the alert function, only operate with diode module. Ordering data Screw connection Note Type CP SNT3 250W 24V 10A Qty. 1 Order No. 8708700000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Accessories Note A.34 1366860000 – 2013 connectPower 3-phase Switch-mode power supplies ECOLINE CP SNT3 500 W 24 V 20 A H A W 3ph VIN AC L1 AC L2 L3 PWM VOUT DC AC/DC Converter + DC Output Voltage control Anti Surge Circuit – Output Current Check & Control R SENSE OCP Output Current Protection OTP/OVP Output Voltage Protection Signal Relay 12 11 14 Technical data Derating curve Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection 3x400 V AC / 400...500 V AC ±15 % 1.7 A @ 400 V AC 47...63 Hz External via 3 circuit-breakers up to 3…6 A, char. C Varistor 25 24...28 V DC (adjustable via potentiometer) 20 A 480 W < 100 mVPP / bandwidth 20 MHz 105 %..130 % Iconst of max. output load; automatic reset 20 15 10 5 0 0 10 20 30 40 50 60 Ambient temperature (°C) 70 80 30...34 V > 10 ms @ 400 V AC <2% Recommended with diode module 250 V AC (max. 30 V DC) / 1 A Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Status relay / CO contact Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output General data Ambient temperature Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Mounting position, installation notice Installation advice Weight Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 30 Current (A) D 0.5 kV 1.5 kV 3 kV -10 °C+70 °C (Derating ab 55 °C) -20 °C...+85 °C 88% Green LED DIN EN 60950 (SELV) EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 horizontally, on terminal rail TS 35 Clearance: above/below ≥ 3 cm 3 kg CE; cULus; cURus; GL; GOSTME25 mm² Input/Output 4 / 0.13 / 6 125 / 227.5 / 110 mm For redundancy operation or to maintain the alert function, only operate with diode module. Ordering data Screw connection Note Type CP SNT3 500W 24V 20A Qty. 1 Order No. 8708710000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Accessories Note 1366860000 – 2013 A.35 connectPower 3-phase CP SNT3 1000 W 24 V 40 A H A W D 3ph VIN AC L1 AC L2 L3 PWM VOUT DC AC/DC Converter + DC Output Voltage control Anti Surge Circuit – Output Current Check & Control R SENSE OCP Output Current Protection OTP/OVP Output Voltage Protection Signal Relay 12 11 14 Technical data Derating curve Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection 3x400 V AC / 400...500 V AC ±15 % 3.4 A @ 400 V AC 47...63 Hz External via 3 circuit-breakers up to 6...16 A, char. C Varistor 40 24...28 V DC (adjustable via potentiometer) 40 A 960 W < 100 mVPP / bandwidth 20 MHz 105 %..130 % Iconst of max. output load; automatic reset 30 20 10 0 0 10 20 30 40 50 60 Ambient temperature (°C) 70 80 29...34 V > 10 ms @ 400 V AC <2% Direct for same type 250 V AC (max. 30 V DC) / 1 A Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Status relay / CO contact Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output General data Ambient temperature Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Mounting position, installation notice Installation advice Height x width x depth Weight Approvals Dimensions Clamping range (nominal / min. / max.) 50 Current (A) Switch-mode power supplies ECOLINE 0.5 kV 1.5 kV 3 kV -10 °C+70 °C (Derating ab 55 °C) -20 °C...+85 °C 88% Green LED DIN EN 60950 (SELV) EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 horizontally, on terminal rail TS 35 Clearance: above/below ≥ 3 cm 150 / 280 / 125 mm 3.5 kg CE; GL; GOSTME25; UL mm² Note Input 4 / 0.1 / 6 Output 10 / 0.3 / 16 For redundancy operation or to maintain the alert function, only operate with diode module. Ordering data Screw connection Note Type CP SNT3 1000W 24V 40A Qty. 1 Order No. 8708730000 The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Accessories Note A.36 1366860000 – 2013 connectPower diode module CP DM 10 Switch-mode power supplies ECOLINE CP DM 20 H A W D +V E1 E2 –V –V DC E1 E2 –V -V +V -V + +V –V DC – E1 E2 -V E1 E2 -V Technical data Input Input voltage Input current Output Output voltage Output current General data Ambient temperature Storage temperature Degree of efficiency at max. load Mounting position, installation notice Installation advice Height x width x depth Weight Approvals Dimensions Clamping range (nominal / min. / max.) mm² 40 V DC max. 2 x 0...10 A max. 40 V DC max. 2 x 0...20 A max. Uin - 0.5 V typical 0...20 A max. or 10 A max. for redundancy operation Uin - 0.5 V typical 0...40 A max. or 20 A max. for redundant operations -10 °C...+55 °C -20 °C...+85 °C 95.5% horizontally, on terminal rail TS 35 Clearance: side ≥ 2 cm; above/below ≥ 10 cm 125 / 55.5 / 110 mm 0.4 kg CE; cULus; cURus -10 °C...+55 °C -20 °C...+85 °C 97.5% horizontally, on terminal rail TS 35 Clearance: side ≥ 2 cm; above/below ≥ 10 cm 125 / 55.5 / 110 mm 0.4 kg CE; cULus; cURus Input 4 / 0.13 / 6 Input 4 / 0.13 / 6 Output 4 / 0.13 / 6 Output 10 / 0.32 / 16 Note Ordering data Screw connection Type CP DM 10 Qty. 1 Order No. 8710620000 Type CP DM 20 Qty. 1 Order No. 8768650000 Note Accessories Note 1366860000 – 2013 A.37 Switch-mode power supplies INSTAPOWER connectPower single-phase CP SNT 24 W 28 V 1 A CP SNT 24 W 24 V 1 A A L AC/DC N PWM L + FUSE N DC + L − N FUSE + − – Technical data Input Input voltage Input current Input frequency Turn-on current limit Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Max. capacitance at output Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output Electrical isolation, I/O rail General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Standards Approvals EMC standards Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note mm² 85...265 V AC, 120...300 V DC 460 mA @ 115 V AC; 250 mA @ 230 V AC 50/ 60 Hz Thermistor 2 A time-lag fuse (internal) Varistor 85...265 V AC, 120...300 V DC 460 mA @ 115 V AC; 250 mA @ 230 V AC 50/ 60 Hz Thermistor 2 A time-lag fuse (internal) Varistor 28 V DC 1A 28 W <2% Surge current / thermal cut-out 24 V DC 1A 24 W <2% Surge current / thermal cut-out Varistor 35 ms @ 115 V AC / 160 ms @ 230 V AC 0.5% 8000 µF Varistor 35 ms @ 115 V AC / 160 ms @ 230 V AC 0.5% 8000 µF 0.5 kV 1.5 kV 3 kV 4 kV 0.5 kV 1.5 kV 3 kV 4 kV -20...+50 °C -40 °C...+85 °C 78% DIN EN 50178, DIN EN 60950, IEC950 CE; CSA; GOSTME25 EN 61000-6 /-2, -3 -20...+50 °C -40 °C...+85 °C 78% DIN EN 50178, DIN EN 60950, IEC950 CE; CSA; CSAEX; GOSTME25 EN 61000-6 /-2, -3 Input/Output 4 / 0.08 / 4 90.5 / 52 / 62.5 mm Input/Output 4 / 0.08 / 4 90.5 / 52 / 62.5 mm Derating loss: 33% @ 60°C The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Derating loss: 33% @ 60°C The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Type CP SNT 24W 28V 1A Type CP SNT 24W 24V 1A Ordering data Screw connection Qty. 1 Order No. 9928890028 Qty. 1 Order No. 9928890024 Note Accessories Note A.38 1366860000 – 2013 connectPower single-phase CP SNT 24 W 15 V 1.5 A Switch-mode power supplies INSTAPOWER CP SNT 24 W 12 V 1.5 A A L AC/DC N PWM L + FUSE N DC + L − N FUSE + − – Technical data Input Input voltage Input current Input frequency Turn-on current limit Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Max. capacitance at output Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output Electrical isolation, I/O rail General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Standards Approvals EMC standards Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note mm² 85...265 V AC, 120...300 V DC 460 mA @ 115 V AC; 250 mA @ 230 V AC 50/ 60 Hz Thermistor 2 A time-lag fuse (internal) Varistor 85...265 V AC, 120...300 V DC 460 mA @ 115 V AC; 250 mA @ 230 V AC 50/ 60 Hz Thermistor 2 A time-lag fuse (internal) Varistor 15 V DC 1.5 A 22.5 W <2% Surge current / thermal cut-out 12 V DC 1.5 A 18 W <2% Surge current / thermal cut-out Varistor 35 ms @ 115 V AC / 160 ms @ 230 V AC 0.5% 8000 µF Varistor 35 ms @ 115 V AC / 160 ms @ 230 V AC 0.5% 8000 µF 0.5 kV 1.5 kV 3 kV 4 kV 0.5 kV 1.5 kV 3 kV 4 kV -20...+50 °C -40 °C...+85 °C 78% DIN EN 50178, DIN EN 60950, IEC950 CE; CSA; GOSTME25 EN 61000-6 /-2, -3 -20...+50 °C -40 °C...+85 °C 78% DIN EN 50178, DIN EN 60950, IEC950 CE; CSA; GOSTME25 EN 61000-6 /-2, -3 Input/Output 4 / 0.08 / 4 90.5 / 52 / 62.5 mm Input/Output 4 / 0.08 / 4 90.5 / 52 / 62.5 mm Derating loss: 33% @ 60°C The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Derating loss: 33% @ 60°C The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Type CP SNT 24W 15V 1.5A Type CP SNT 24W 12V 1.5A Ordering data Screw connection Qty. 1 Order No. 9928890015 Qty. 1 Order No. 9928890012 Note Accessories Note 1366860000 – 2013 A.39 Switch-mode power supplies INSTAPOWER connectPower single-phase CP SNT 24 W 5 V 2 A D W A L AC/DC N H PWM L + FUSE + − N DC – Technical data Input Input voltage Input current Input frequency Turn-on current limit Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection 85...265 V AC, 120...300 V DC 460 mA @ 115 V AC; 250 mA @ 230 V AC 50/ 60 Hz Thermistor 2 A time-lag fuse (internal) Varistor 5 V DC 2A 10 W <2% Surge current / thermal cut-out Varistor 35 ms @ 115 V AC / 160 ms @ 230 V AC 0.5% 8000 µF Surge protection Mains failure bridge-over time Control at 10...100% load Max. capacitance at output Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output Electrical isolation, I/O rail General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Standards Approvals EMC standards Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 0.5 kV 1.5 kV 3 kV 4 kV -20...+50 °C -40 °C...+85 °C 78% DIN EN 50178, DIN EN 60950, IEC950 CE; CSA; GOSTME25 EN 61000-6 /-2, -3 mm² Input/Output 4 / 0.08 / 4 90.5 / 52 / 62.5 mm Derating loss: 33% @ 60°C The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Ordering data Screw connection Type CP SNT 24W 5V 2A Qty. 1 Order No. 9928890005 Note Accessories Note A.40 1366860000 – 2013 connectPower single-phase Switch-mode power supplies INSTAPOWER CP SNT 25 W 5 V 5 A D W L AC/DC N A H PWM L + FUSE + − N DC – Technical data Derating curve Input Input voltage Input current Input frequency Turn-on current limit Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection 85...264 V AC / 110...370 V DC 500 mA at rated load @ 230 V AC 50/ 60 Hz Yes Fusible link 2.5 A (T) / 250 V Current (A) 5 4...8 V DC (adjustable via potentiometer) 5A 25 W 120 mVSS 105 %...150 % Iconst of max. output load; automatic reset 4 3 2 1 0 0 10 20 30 40 50 60 Ambient temperature (°C) 70 80 Varistor 11 ms @ 115 V AC / 50 ms @ 230 V AC 1% 10000 µF Surge protection Mains failure bridge-over time Control at 10...100% load Max. capacitance at output Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output Electrical isolation, I/O rail General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Standards Approvals EMC standards Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 6 0.5 kV 1.5 kV 3 kV 4 kV -10...+70 °C (Derating ab 55 °C) -20 °C...+85 °C 70% DIN EN 50178 (PELV), DIN EN 60950 (SELV) cCSAus; cURus; GOSTME25; UL EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4 mm² Input/Output 2.5 / 0.5 / 4 90.5 / 70 / 62.5 mm The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Ordering data Screw connection Type CP SNT 25W 5V 5A Qty. 1 Order No. 8754960000 Note Accessories Note 1366860000 – 2013 A.41 Switch-mode power supplies INSTAPOWER connectPower single-phase CP SNT 48 W 12 V 4 A D W A L AC/DC N H PWM L + FUSE + − N DC – Technical data Derating curve Input Input voltage Input current Input frequency Turn-on current limit Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection 85...264 V AC / 110...370 V DC 500 mA at rated load @ 230 V AC 50/ 60 Hz Yes Fusible link 2.5 A (T) / 250 V Current (A) 5 9...15 V DC (adjustable via potentiometer) 4A 48 W 120 mVSS 105 %...150 % Iconst of max. output load; automatic reset 4 3 2 1 0 0 10 20 30 40 50 60 Ambient temperature (°C) 70 80 Varistor 11 ms @ 115 V AC / 50 ms @ 230 V AC 1% 10000 µF Surge protection Mains failure bridge-over time Control at 10...100% load Max. capacitance at output Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output Electrical isolation, I/O rail General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Standards Approvals EMC standards Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 6 0.5 kV 1.5 kV 3 kV 4 kV -10...+70 °C (Derating ab 55 °C) -20 °C...+85 °C 75% DIN EN 50178 (PELV), DIN EN 60950 (SELV) cCSAus; CE; cULus; cURus; GOSTME25; UL EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4 mm² Input/Output 2.5 / 0.5 / 4 90.5 / 70 / 62.5 mm The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Ordering data Screw connection Type CP SNT 48W 12V 4A Qty. 1 Order No. 8754970000 Note Accessories Note A.42 1366860000 – 2013 connectPower single-phase Switch-mode power supplies INSTAPOWER CP SNT 48 W 24 V 2 A D W L AC/DC N A H PWM L + FUSE + − N DC – Technical data Derating curve Input Input voltage Input current Input frequency Turn-on current limit Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection 85...264 V AC / 110...370 V DC 500 mA at rated load @ 230 V AC 50/ 60 Hz Yes Fusible link 2.5 A (T) / 250 V Current (A) 15...28 V DC (adjustable via potentiometer) 2A 48 W 120 mVSS 105 %...150 % Iconst of max. output load; automatic reset 2 1.5 1 0.5 0 0 10 20 30 40 50 60 Ambient temperature (°C) 70 80 Varistor 11 ms @ 115 V AC / 50 ms @ 230 V AC 1% 10000 µF Surge protection Mains failure bridge-over time Control at 10...100% load Max. capacitance at output Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output Electrical isolation, I/O rail General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Standards Approvals EMC standards Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 3 2.5 0.5 kV 1.5 kV 3 kV 4 kV -10...+70 °C (Derating ab 55 °C) -20 °C...+85 °C 78% DIN EN 50178 (PELV), DIN EN 60950 (SELV) cCSAus; cULus; cURus; GOSTME25; UL EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4 mm² Input/Output 2.5 / 0.5 / 4 90.5 / 70 / 62.5 mm The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Ordering data Screw connection Type CP SNT 48W 24V 2A Qty. 1 Order No. 8739140000 Note Accessories Note 1366860000 – 2013 A.43 Switch-mode power supplies INSTAPOWER connectPower single-phase CP SNT 48 W 48 V 1 A D W A L AC/DC N H PWM L + FUSE + − N DC – Technical data Derating curve Input Input voltage Input current Input frequency Turn-on current limit Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection 85...264 V AC / 110...370 V DC 500 mA at rated load @ 230 V AC 50/ 60 Hz Yes Fusible link 2.5 A (T) / 250 V Current (A) 46...55 V DC (adjustable via potentiometer) 1A 48 W 120 mVSS 105 %...150 % Iconst of max. output load; automatic reset 1.5 1 0.5 0 0 10 20 30 40 50 60 Ambient temperature (°C) 70 80 Varistor 11 ms @ 115 V AC / 50 ms @ 230 V AC 1% 10000 µF Surge protection Mains failure bridge-over time Control at 10...100% load Max. capacitance at output Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output Electrical isolation, I/O rail General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Standards Approvals EMC standards Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 2 0.5 kV 1.5 kV 3 kV 4 kV -10...+70 °C (Derating ab 55 °C) -20 °C...+85 °C 80% DIN EN 50178 (PELV), DIN EN 60950 (SELV) cCSAus; cURus; GOSTME25; UL EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4 mm² Input/Output 2.5 / 0.5 / 4 90.5 / 70 / 62.5 mm The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Ordering data Screw connection Type CP SNT 48W 48V 1A Qty. 1 Order No. 8879230000 Note Accessories Note A.44 1366860000 – 2013 connectPower single-phase Switch-mode power supplies WAVEPOWER CP SNT 12 W 24 V 0.5 A D H L AC/DC N PWM A W + DC – Technical data Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output Electrical isolation, I/O rail General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Power factor correction Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 85...265 V AC, 120...300 V DC 260 mA @ 115 V AC; 180 mA @ 230 V AC 50/ 60 Hz 2 A time-lag fuse (internal) Varistor 24 V DC 0.5 A 12 W 0.1 % Surge current / thermal cut-out Varistor 30 ms @ 115 V AC / 80 ms @ 230 V AC 0.6% No 0.5 kV 1.5 kV 3 kV 4 kV -20...+50 °C -40 °C...+85 °C 80% Green LED DIN EN 50178, DIN EN 60950, IEC950 IEC 61000-6 /-2, -3 No CE; CSA; GOSTME25 mm² Input/Output 2.5 / 0.5 / 2.5 92.4 / 22.5 / 112.4 mm Ordering data Screw connection Type CP SNT 12W 24V 0.5A Qty. 1 Order No. 9918840024 Note Accessories Note 1366860000 – 2013 Supply voltage 24V and 0V can be cross-connected with ZQV 2.5N/2 A.45 Switch-mode power supplies connectPower connectPower single-phase CP SNT 55 W 48 V 1.04 A CP SNT 55 W 24-28 V 2.3 A H D A W L AC/DC N PWM + L DC – + + FUSE L + + FUSE N N + + 85...265 V AC, 120...300 V DC 1.1 A @ 115 V AC; 0.55 A @ 230 V AC 50/ 60 Hz 2 A time-lag fuse (internal) Varistor 85...265 V AC, 120...300 V DC 1.1 A @ 115 V AC; 0.55 A @ 230 V AC 50/ 60 Hz 2 A time-lag fuse (internal) Varistor 48 V DC 1.04 A 50 W < 50 mVeff Surge current / thermal cut-out Varistor 30 ms @ 115 V AC / 180 ms @ 230 V AC 1% No 24...28 V DC 2.3 A 55 W < 50 mVeff Surge current / thermal cut-out Varistor 30 ms @ 115 V AC / 180 ms @ 230 V AC 1% No 0.5 kV 1.5 kV 3 kV 3 kV 0.5 kV 1.5 kV 3 kV 3 kV -20...+40 °C -40 °C...+85 °C 78% Green LED DIN EN 50178, DIN EN 60950, IEC950 IEC 61000-6 /-2, -3 No CE; CSA; GOSTME25 -20...+40 °C -40 °C...+85 °C 78% Green LED DIN EN 50178, DIN EN 60950, IEC950 IEC 61000-6 /-2, -3 No CE; CSA; CSAEX; GOSTME25 Input/Output 4 / 0.1 / 4 98 / 57 / 131 mm Input/Output 4 / 0.1 / 4 98 / 57 / 131 mm Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Type CP SNT 55W 48V 1.04A Type CP SNT 55W 24-28V 2.3A Technical data Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output Electrical isolation, I/O rail General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Power factor correction Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note mm² Ordering data Screw connection Qty. 1 Order No. 9927480048 Qty. 1 Order No. 9927480024 Note Accessories Note A.46 Bracket for wall mounting: 7920560000 Bracket for wall mounting: 7920560000 1366860000 – 2013 connectPower single-phase CP SNT 55 W 12-15 V 3 A Switch-mode power supplies connectPower CP SNT 55 W 5 V 3 A H D A W L AC/DC N PWM + L DC – + + FUSE L + + FUSE N N + + 85...265 V AC, 120...300 V DC 1.1 A @ 115 V AC; 0.55 A @ 230 V AC 50/ 60 Hz 2 A time-lag fuse (internal) Varistor 85...265 V AC, 120...300 V DC 1.1 A @ 115 V AC; 0.55 A @ 230 V AC 50/ 60 Hz 2 A time-lag fuse (internal) Varistor 12...15 V DC 3A 36 W < 50 mVeff Surge current / thermal cut-out Varistor 30 ms @ 115 V AC / 180 ms @ 230 V AC 1% No 5 V DC 3A 15 W < 50 mVeff Surge current / thermal cut-out Varistor 30 ms @ 115 V AC / 180 ms @ 230 V AC 1% No 0.5 kV 1.5 kV 3 kV 3 kV 0.5 kV 1.5 kV 3 kV 3 kV -20...+40 °C -40 °C...+85 °C 78% Green LED DIN EN 50178, DIN EN 60950, IEC950 IEC 61000-6 /-2, -3 No CE; CSA; GOSTME25 -20...+40 °C -40 °C...+85 °C 78% Green LED DIN EN 50178, DIN EN 60950, IEC950 IEC 61000-6 /-2, -3 No CE; CSA; GOSTME25 Input/Output 4 / 0.1 / 4 98 / 57 / 131 mm Input/Output 4 / 0.1 / 4 98 / 57 / 131 mm Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Type CP SNT 55W 12-15V 3A Type CP SNT 55W 5V 3A Technical data Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output Electrical isolation, I/O rail General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Power factor correction Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note mm² Ordering data Screw connection Qty. 1 Order No. 9927480012 Qty. 1 Order No. 9927480005 Note Accessories Note 1366860000 – 2013 Bracket for wall mounting: 7920560000 Bracket for wall mounting: 7920560000 A.47 Switch-mode power supplies connectPower connectPower single-phase CP SNT 160 W 48 V 3.5 A CP SNT 160 W 24-28 V 6.5 A H D A W L AC/DC N PWM + DC – Technical data Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output Electrical isolation, I/O rail General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Power factor correction Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note mm² min. 85/138 V AC, max. 195/250 V AC, typ. 115...230 V AC 2.9 A @ 115 V AC; 1.45 A @ 230 V AC 50/ 60 Hz 6.3 A time-lag fuse (internal) Varistor min. 85/138 V AC, max. 195/250 V AC, typ. 115...230 V AC 2.9 A @ 115 V AC; 1.45 A @ 230 V AC 50/ 60 Hz 6.3 A time-lag fuse (internal) Varistor 48 V DC 3.5 A 168 W 0.2 %eff Overload current and surge protection Varistor 40 ms @ 115 V AC / 50 ms @ 230 V AC 1% No 24...28 V DC 6.5 A 156 W 0.2 %eff Overload current and surge protection Varistor 40 ms @ 115 V AC / 50 ms @ 230 V AC 1% No 0.5 kV 1.5 kV 3 kV 3 kV 0.5 kV 1.5 kV 3 kV 3 kV 0...+50 °C -40 °C...+85 °C 85% Green LED DIN EN 50178, DIN EN 60950, IEC950 EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 No CE; cULus; GOSTME25 0...+50 °C -40 °C...+85 °C 85% Green LED DIN EN 50178, DIN EN 60950, IEC950 EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 No CE; CSA; GOSTME25 Input/Output 4 / 0.1 / 4 127 / 57 / 175 mm Input/Output 4 / 0.1 / 4 127 / 57 / 175 mm Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Type CP SNT 160W 48V 3.5A Type CP SNT 160W 24-28V 6.5A Ordering data Screw connection Qty. 1 Order No. 9925340048 Qty. 1 Order No. 9925340024 Note Accessories Note A.48 Bracket for wall mounting: 7920560000 Bracket for wall mounting: 7920560000 1366860000 – 2013 connectPower single-phase CP SNT 160 W 12-15 V 8 A Switch-mode power supplies connectPower CP SNT 160 W 5 V 8 A H D A W L AC/DC N PWM + DC – Technical data Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output Electrical isolation, I/O rail General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Power factor correction Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note mm² min. 85/138 V AC, max. 195/250 V AC, typ. 115...230 V AC 2.9 A @ 115 V AC; 1.45 A @ 230 V AC 50/ 60 Hz 6.3 A time-lag fuse (internal) Varistor min. 85/138 V AC, max. 195/250 V AC, typ. 115...230 V AC 2.9 A @ 115 V AC; 1.45 A @ 230 V AC 50/ 60 Hz 6.3 A time-lag fuse (internal) Varistor 12...15 V DC 8A 96 W 0.2 %eff Overload current and surge protection Varistor 40 ms @ 115 V AC / 50 ms @ 230 V AC 1% No 5 V DC 8A 40 W 0.2 %eff Overload current and surge protection Varistor 40 ms @ 115 V AC / 50 ms @ 230 V AC 1% No 0.5 kV 1.5 kV 3 kV 3 kV 0.5 kV 1.5 kV 3 kV 3 kV 0...+50 °C -40 °C...+85 °C 85% Green LED DIN EN 50178, DIN EN 60950, IEC950 EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 No CE; cULus; GOSTME25 0...+50 °C -40 °C...+85 °C 85% Green LED DIN EN 50178, DIN EN 60950, IEC950 EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 No CE; cULus; GOSTME25 Input/Output 4 / 0.1 / 4 127 / 57 / 175 mm Input/Output 4 / 0.1 / 4 127 / 57 / 175 mm Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Derating loss: 10% @ 60°CThe internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Type CP SNT 160W 12-15V 8A Type CP SNT 160W 5V 8A Ordering data Screw connection Qty. 1 Order No. 9925340012 Qty. 1 Order No. 9925340005 Note Accessories Note 1366860000 – 2013 Bracket for wall mounting: 7920560000 Bracket for wall mounting: 7920560000 A.49 Switch-mode power supplies connectPower connectPower single-phase CP SNT 300 W 24 V 12.5 A H D A W L AC/DC N PWM + DC – Technical data Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Signalling delay Monitoring function Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output Electrical isolation, I/O rail General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Power factor correction Derating Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 86...265 V AC, 100...200 V DC; typ 115...230 V AC 3.3 A @ 115 V AC; 1.65 A @ 230 V AC 50/ 60 Hz Thermistor Varistor 22...28 V DC adjustable 12.5 A 300 W at 100 kHz: 2 mVSS, At 120 Hz: 20 mV AC eff Overload current and surge protection Varistor 40 ms @ 115 V AC / 40 ms @ 230 V AC 0.2% Yes, max. 5 devices, active current splitting 2s Output voltage, current, temperature 0.5 kV 1.5 kV 3 kV 4 kV -15...+50 °C -40 °C...+85 °C 80% Current limiting: LED yellow / Error: LED red/ On: LED green DIN EN 50178, DIN EN 60950, IEC950 EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 PFC passive Derating: 20% @ 60°C CE; CSA; GOSTME25 mm² Input/Output 4 / 0.1 / 4 155 / 240 / 101 mm The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Ordering data Screw connection Type CP SNT 300W 24V 12.5A Qty. 1 Order No. 9916250024 Note Accessories Note A.50 Bracket for wall mounting: 7920560000 1366860000 – 2013 connectPower 3-phase Switch-mode power supplies connectPower CP SNT 380-480 V AC / 24 V H D A W L1 AC L2 L3 PWM + DC – Technical data Input Input voltage Input current Input frequency Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100% load Parallel connection option Overload protection Insulation coordination (EN 50178) Electrical isolation, output-earth Electrical isolation, input-earth Electrical isolation, input-output Electrical isolation, I/O rail General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Status indication Standards EMC standards Power factor correction Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 306... 550 V AC, typ.: 360...480 V AC 120 mA @ 360 V AC; 100 mA @ 230 V AC 50/ 60 Hz 3 x 1 A time-lag fuse (internal) Varistor 24 V DC 2.3 A 55 W < 50 mVeff Surge current / thermal cut-out Varistor 120 ms @ 360 V AC / 120 ms @ 480 V AC 1% No Surge current / thermal cut-out 0.5 kV 1.5 kV 3 kV 3 kV 0...+50 °C -40 °C...+85 °C 85% Green LED DIN EN 50178, DIN EN 60950, IEC950 EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 No CE; GOSTME25 mm² Input/Output 4 / 0.1 / 4 108 / 60 / 168 mm Derating loss: 10% @ 85 ? The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Ordering data Screw connection Type CP-SNT 380-480VAC/24V Qty. 1 Order No. 9917790324 Note Accessories Note 1366860000 – 2013 Bracket for wall mounting: 7920560000 A.51 Switch-mode power supplies DC/DC converter connectPower CP DCDC 50 W 22-24 V DC 2 A CP DCDC 50 W 15 V DC 3 A H D A W '& ² Chopper Transformer Rectifier and filtering Chopper Transformer Rectifier and filtering '& Technical data Input Input voltage Input fuse Output Output voltage, min. / max. Output current Overload protection General data Ambient temperature (operational) Storage temperature Status indication Switching frequency Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note mm² 18...30 V DC, typ. 24 V DC internal 18...30 V DC, typ. 24 V DC internal 22...24 V DC 2A Surge current cut-out with self-reset 15 V DC 3A Surge current cut-out with self-reset -10...+60 °C (Derating ab 50 °C) -40 °C...+85 °C Green LED 200 kHz CE; CSA; CSAEX; cULus; GOSTME25 -10...+60 °C (Derating ab 50 °C) -40 °C...+85 °C Green LED 200 kHz CE; CSA; CSAEX; cULus; GOSTME25 Input/Output 4 / 0.1 / 4 98 / 57 / 131 mm Input/Output 4 / 0.1 / 4 98 / 57 / 131 mm Ordering data Screw connection Type CP DCDC 50W 22-24V 2A Qty. 1 Order No. 9919372424 Type CP DCDC 50W 15V 3A Qty. 1 Order No. 9919372415 Note Accessories Note A.52 Bracket for wall mounting: 7920560000 Bracket for wall mounting: 7920560000 1366860000 – 2013 CP DCDC 50 W 12 V DC 3 A CP DCDC 50 W 20-24 V DC 2 A Switch-mode power supplies DC/DC converter CP DCDC 50 W 15 V DC 3 A A Chopper Transformer Rectifier and filtering Chopper Transformer Rectifier and filtering Chopper Transformer 10…14 V DC, type 12V DC internal 10…14 V DC, type 12V DC internal 10…14 V DC, type 12V DC internal 10.5...14.5 V DC 3A Surge current cut-out with self-reset 20.5...29.5 V DC 2A Surge current cut-out with self-reset 13...18 V DC 3A Surge current cut-out with self-reset -10...+60 °C (Derating ab 50 °C) -40 °C...+85 °C Green LED 200 kHz CE; CSA; CSAEX; cULus; GOSTME25 -10...+60 °C (Derating ab 50 °C) -40 °C...+85 °C Green LED 200 kHz CE; CSA; CSAEX; cULus; GOSTME25 -10...+60 °C (Derating ab 50 °C) -40 °C...+85 °C Green LED 200 kHz CE; CSA; CSAEX; cULus; GOSTME25 Input/Output 4 / 0.1 / 4 98 / 57 / 131 mm Input/Output 4 / 0.1 / 4 98 / 57 / 131 mm Input/Output 4 / 0.1 / 4 98 / 57 / 131 mm Type CP DCDC 50W 12V 3A Bracket for wall mounting: 7920560000 1366860000 – 2013 Qty. 1 Order No. 9919371212 Type CP DCDC 50W 22-24V 2A Bracket for wall mounting: 7920560000 Qty. 1 Order No. 9919371224 Type CP DCDC 50W 15V 3A Rectifier and filtering Qty. 1 Order No. 9919371215 Bracket for wall mounting: 7920560000 A.53 Switch-mode power supplies DC/DC converter connectPower CP DCDC 50 W 12 V DC 3 A CP DCDC 50 W 5 V DC 8 A H D A W '& ² Chopper Transformer Rectifier and filtering Chopper Transformer Rectifier and filtering '& Technical data Input Input voltage Input fuse Output Output voltage, max. Output current Overload protection General data Ambient temperature (operational) Storage temperature Status indication Switching frequency Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note mm² 18...30 V DC, typ. 24 V DC internal 18...30 V DC, typ. 24 V DC internal 10.5...14.5 V DC 3A Surge current cut-out with self-reset 5 V DC 8A Surge current cut-out with self-reset -10...+60 °C (Derating ab 50 °C) -40 °C...+85 °C Green LED 200 kHz CE; CSA; CSAEX; cULus; GOSTME25 -10...+60 °C (Derating ab 50 °C) -40 °C...+85 °C Green LED 200 kHz CE; CSA; CSAEX; cULus; GOSTME25 Input/Output 4 / 0.1 / 4 98 / 57 / 131 mm Input/Output 4 / 0.1 / 4 98 / 57 / 131 mm Ordering data Screw connection Type CP DCDC 50W 12V 3A Qty. 1 Order No. 9919372412 Type CP DCDC 50W 5V 8A Qty. 1 Order No. 9919372405 Note Accessories Note A.54 Bracket for wall mounting: 7920560000 Bracket for wall mounting: 7920560000 1366860000 – 2013 A 1366860000 – 2013 A.55 Switch-mode power supplies Switch-mode power supplies connectPower DC/DC converter ConnectPower DC/DC converter DC voltage converter for preparation and potential isolation in 24 V DC systems •Overvoltage category III •Class III protection •Status of relay contact •DC OK transistor output A % { \u Technical data Temperature derating 130 Pout [% Pn] 120 110 100 90 80 70 60 20 30 40 50 60 Ambient temperature [°C] 70 80 General technical specifications Output characteristic curve / current limit Earth discharge current Ambient temp. Operating / storage temperature Max. permitted humidity (operational) Protection degree Class of protection Contamination degree Insulation voltage Overvoltage category MTBF Protection against load reverse voltages Parallel capability (without diode module) Mountable side-by-side without gaps Housing version, metal Signal operations Mounting position, installation notice Metal clip-on foot EMC / shock / vibration Noise emission according to EN55022 Interference immunity tests, according to Limiting of mains voltage harmonic currents Resistance against vibration and shock Electrical safety (applied standards) Electrical equipment of machines Safety transformers for switched-mode power units Machinery with electronic equipment Safety extra-low voltage Protective separation / protection against electrical shock Protection against dangerous shock currents Accessories Diode module (for redundant power supply) Capacity module (for pulse triggering of circuit breakers) A.56 IU / > 120 % IN < 0.005 mA –25 °C … +70 °C / –40 °C … +85 °C 5 %…95 % RH IP20 III 2 2.5 kV AC 1 min. / 1.5 kV AC 1 min. / 0.5 kV AC 1 min. III > 500,000 hrs. according to IEC 1709 (SN29500) 33…34 V DC Yes, max. 5 Yes Resistant to corrosion LED green / red Horizontal on TS35 DIN rail, above and below 50 mm Clearance for air circulation, suitable for aligning without clearance gap For installation in rotating systems Yes Class B EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields), EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN610004-6 (conducted), EN61000-4-11 (Dips) According to EN 61000-3-2 According to EN50178, shock: 5 g in all directions According to EN60204 According to EN61558-2-17 According to EN50178 / VDE0160 SELV according to EN60950, PLEV according to EN60204 VDE0100-410 / according to DIN57100-410 According to VDE0106-101 Type CP M DM 20 CP M CAP Qty. 1 1 Order No. 1222210000 1222240000 1366860000 – 2013 Switch-mode power supplies connectPower DC/DC converter CP DCDC 250W 24V 10A connectPower DC/DC converter A D + H + DC – – DC OK 14 13 DC W Technical data Input data Rated input voltage Input voltage range, DC Current consumption, DC (typ.) Current consumption, DC max. Max. inrush current Input fuse (internal) Recommended back-up fuse Output data Nominal output voltage Adjustment range of output voltage Ramp-up time Max. residual ripple Nominal output current @ Unom Short-circuit protection Overload protection Power boost @ 24 V DC, 60 °C, ED = 5 % General information Efficiency (typ.) Max. power loss (no load) Max. power loss (nominal load) Mains failure bridging @ Inom Length x width x height Weight Signal indication LED green (DC OK) LED red (fault) DC OK transistor output "1" (max. load) DC OK transistor output "0" DC OK short circuit resistant Floating contact Contact load (NO contact) Relay on/off Connection data Screw connection Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil min/max Tightening torque Reverse polarity protection Approvals Approvals Ordering data 1366860000 – 2013 24 V DC 18…31.2 V DC 11 A 15.5 A < 10 A Yes 16 A / DI/II Fusible link 16 A, Char. B Circuit breaker 16 A, Char. C Circuit breaker 24 V DC ± 1%, 22.5…29.5 V DC ≤ 100 ms < 50 mVss 10 A @ 24 V DC Yes Yes 12 A for 1 min, ED = 5 % mm 91% <2W < 24 W > 7 ms @ 24 V DC 150 x 60 x 130 1.25 kg Output voltage ≥ 21.6 V Output voltage ≤ 20.4 V Output voltage ≥ 21.6 V ( max. 250 mA) Output voltage ≤ 20.4 V Yes Yes max. 30V DC/0.5 A Output voltage > 21.6 V / < 20.4 V Input Output Screw connection Screw connection 2 für (+-) 7 für (DCOK,13,14,++ ––) 0.5 / 6 mm² 0.5 / 6 mm² 0.5 / 2.5 mm² 0.5 / 2.5 mm² 26 / 12 26 / 12 0.5 … 0.6 Nm Yes CE, cURus, TÜV(IEC 60950-1), cULus, GL Type CP DCDC 250W 24V 10A Qty. 1 Order No. 1313320010 A.57 A A.58 1366860000 – 2013 Switch-mode power supplies Uninterruptible power supplies (UPS) Contents Uninterruptible power supplies (UPS) Uninterruptible power supplies (UPS) 1366860000 – 2013 Overview B.2 UPS control unit B.4 Battery modules B.6 Buffer modules B.8 B B.1 Uninterruptible power supplies (UPS) Uninterruptible power supplies (UPS) – Overview Uninterruptible power supplies Weidmüller‘s uninterruptible power supplies reliably protect 24 V DC consumers from voltage drop-outs and dips, such as those that could occur as a result of mains faults. These products therefore play a key role in increasing systems availability. B The buffer module is the perfect solution for bridging short-term power supply failures or dips of up to 100 ms. The capacitor-based technology enables maintenance-free operation, depending on the application, of up to 10 years. The UPS control unit, together with the accompanying battery module and the power supply, form a complete DC UPS system with support times in minutes or hours. The modular construction allows for the overall load to be distributed into non-safe and safe load circuits, such that often a smaller UPS can be designed. A huge variety of operating types are available to suit the particular application precisely. A remote input to block battery operation, as well as multiple signal outputs, enable remote operation of the UPS. UPS with battery module 0DLQV 5HPRWHGLVFRQQHFWLRQ ,QWHUORFN 3520 $& '& 9'& ² 5HOD\DQG WUDQVLVWRURXWSXWV &3'&8369 836FRQWUROXQLW 9'& ² 6DIH ORDG %DWWHU\PRGXOH &3$%DWWHU\9'& 1RQVDIH ORDG UPS with buffer module Relay and transistor ouput Mains PRO-M AC DC +24 V DC + – CP DC BUFFER 24V 20A + Buffer module +24 V DC Safe load – Non-safe load B.2 1366860000 – 2013 Uninterruptible power supplies (UPS) Uninterruptible power supplies (UPS) – Overview Can your facility afford to experience a power failure? Allow us to connect you so that you are safe from failure and downtime. Let’s connect. B It is critical to safeguard a facility‘s power supply in the event of an outage. You cannot do without the important signals from the field, which serve to control the entire process. In addition, you also need to monitor a whole range of functions and performance parameters for your facility. Our highly modular power supply concept will support you in the practical fulfilment of all your requirements. At the same time, we will also familiarise ourselves with your future requirements and provide you with an individual, tailor-made solution, with components that are precisely aligned to work with one another. For a continual, lasting power supply and clean control voltage, we use redundant circuits, selective short-circuit solutions, battery reservoirs and DC/DC converters. And because lightning and power surges can put an uninterrupted power supply in a production facility at risk, we also provide lightning and overvoltage protection. The VPU series provides unrestricted operation of power supplies and automation devices such as sensors, actuators and control units. The subsequent availability of the power supply means that all devices will restart in a controlled manner. Let’s connect. 1366860000 – 2013 PRO-M •Used to save space in automation technology • Individual modulation of the output power • Up to 5 devices can be switched directly, in parallel • Optional diode modules with fault signalling • Expanded temperature range –25 °C to 70 °C UPS control unit • Different status relays for status monitoring •Direct switchover to battery operation in the event of malfunction • Automatic reconnection to load when power recovers •Long battery life due to integrated deep discharge protection • Optimised charging feature B.3 Uninterruptible power supplies (UPS) UPS control unit •Two 24 V models in 10 A/20 A and 40 A •Temperature-compensated charging feature for long battery life •Integrated battery diagnostics including continuous availability test •Status relay and additional transistor outputs for remote monitoring •Convenient LED displays for easy error analysis { \u % B Technical data Indication Status relay ( max.load 30 V AC/DC 0.1 A) Transistor outputs (24 to 27 V DC max. load 150 mA) LED status indicator General technical data Ambient temperature (operational) Storage temperature Max. perm. air humidity Protection degree Class of protection Pollution severity level Overvoltage category Insulation voltage input/output to housing/ground MTBF Protection against reverse voltages from the load Parallel connection option Housing version Mounting position, installation notice Overload protection Short-circuit protection EMC / shock / vibration Interference emission Interference immunity tests Resistance against vibration and shock Electrical safety (applied standards) Electrical equipment of machines Safety transformers for switch-mode power supplies Machinery with electronic equipment Extra-low voltage protection Block diagram Interlock – 1 Interlock + 2 Temperature 6 Sensor 7 –25 °C…+70 °C –40 °C…+85 °C 5…95 % IP 20 3 2 III 1300 V DC 1 min (typetest) > 500,000 hours acc. to IEC 1709 32…34 V DC Yes, only with diode module for redundancy Metal, corrosion resistant Horizontal on mounting rail TS35, 50 mm above and below Space for free movement of air Yes Yes Acc. to EN55022 Class B Acc.to EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (fields), EN61000-4-4 (burst), EN61000-4-5 (surge), EN610004-6 (conducted), EN61000-4-11 (dips) Acc.to IEC60954 Vibration: 2.3 g, Acc.to IEC60068-2-31 shock: 30 g in all directions Acc. to EN60204 Acc. to EN61558-2-17 Acc. to EN50178 / VDE0160 SELV acc. to EN60950, PLEV acc. to EN60204 Cabling 3 Alarm Battery Capacity Normal / Buffering Alarm Cut-off / Bat.Failure Selector switches – Buffer time – Battery size – DIP switch – 10/20A (only1370050010) 4 Buffering 5 Charging 11 14 Alarm 12 21 24 Buffering 22 31 34 Charging 32 + µC + 24V DC Input Charger – 24V DC Output – Bat – B.4 Fault (alarm), battery operation (buff.), charging (charg.) Fault (alarm), battery operation (buff.), charging (charg.) Three-colour LED: battery capacities > 85 % green, > 40 % yellow, > 20 % red, < 20 % red (flashing) Green/yellow LED: normal / buffering Yellow/red LED: temperature alarm / alarm Yellow/red LED: switch-off / battery fault + + Unbuffered DC Load – + – + – + 24V DC Output Buffered DC Load – + – + – + – + Input Battery Output – + Power Supply DC UPS Battery Module PRO–M Series CP DC UPS 24V DC 20A/10A CP DC UPS 24V DC 40A CP A BATTERY 24V DC .. Ah 1 2 3 4 5 11 21 31 6 7 12 14 22 24 32 34 7 6 Temperature Sensor 1366860000 – 2013 CP DC UPS 24V 20A/10A UPS control unit Uninterruptible power supplies (UPS) UPS control unit CP DC UPS 24V 40A ' + : B Technical data Input Rated input voltage Input voltage range Rated input voltage (up to 60 °C) Input current, max. (to 45 °C) Input fuse Standby current (without battery) Standby current (with fully charged battery) Reverse polarity protection Output Rated output voltage Output voltage, normal operation (Imax) Output voltage, battery operation (Imax) Rated output current (up to 60 °C) Continuous output current (up to 70 °C), derating from 60 °C Continuous output current (up to 45 °C) Power Boost@24 V DC, 60 °C Integrated battery charger Charging feature Charging voltage (temperature compensated) Temperature coefficient Charging current Battery availability test Battery module Rated voltage Storage medium (AGM battery) Parallel connection option Operating elements and control inputs Output current selector switch Battery in Ah selector switch Buffer times in minutes selector switch DIP switch Remote disconnection (Interlock) Temperature sensor connection General data Buffer times Efficiency Power loss Height x width x depth Weight Approvals Connection data Conductor connection system Wire cross-section, rigid mm² (min./max.) Wire cross-section, flexible mm² (min./max.) Wire cross-section, AWG/kcmil (min./max.) Stripping length (mm) Tightening torque range (NM) Ordering data 1366860000 – 2013 24 V DC 20…30 V DC ≤ 13 A (for 10 A) │≤ 23 A (for 20 A) ≤ 15 A (for 10 A)│≤ 27 A (for 20 A) Yes, 30 A max. 200 mA max. 0,5 A Yes 24 V DC 20…30 V DC ≤ 43 A ≤ 51 A Yes, 60 A max. 200 mA max. 0,5 A Yes 24 V DC Vo = Vin – 0,2 V Vo = Vin – 0,3 V 10 A / 20 A 7,5 A / 15 A 12 A / 24 A 12 A / 24 A for 1 min, ED = 5 % 24 V DC Vo = Vin – 0,2 V Vo = Vin – 0,3 V 40 A 24 A 48 A 48 A for 1 min, ED = 5 % IU characteristic curve 27, 48 V @ 20 °C – 48 mV / °C 0,15 CA Yes, each minute IU characteristic curve 27, 48 V @ 20 °C – 48 mV / °C 0,15 CA Yes, each minute 24 V DC 1,3 Ah, 3,4 Ah, 7,2 Ah, 12 Ah, 17 Ah (selectable, with rotary switch) Yes, max. 2 24 V DC 3,4 Ah, 7,2 Ah, 12 Ah, 17 Ah (selectable, with rotary switch) Yes, max. 2 10A / 20A 1,3 / 3,4 / 7,2 / 12 / 17 / No Battery / Service 0,5 / 1 / 3 / 5 / 10 / 20 / 30 / 45 / ∞ / ∞ w/0 Inversion of the transistor outputs; operation without temperature sensor Yes Yes, for NTC 10 KΩ No 3,4 / 7,2 / 12 / 17 / No Battery / Service 0,5 / 1 / 3 / 5 / 10 / 20 / 30 / 45 / ∞ / ∞ w/0 Inversion of the transistor outputs; operation without temperature sensor Yes Yes, for NTC 10 KΩ Depending on the connected battery (adjustable) ≥ 98 % Normal operation, battery charged ≥ 96 % Normal operation, battery charging ≥ 98 % Battery operation <10 W 130 / 66 / 150 mm 0,98 kg Depending on the connected battery (adjustable) ≥ 98 % Normal operation, battery charged ≥ 96 % Normal operation, battery charging ≥ 98 % Battery operation <10 W 130 / 66 / 150 mm 1,0 kg CE, TÜV; Pending: cURus, cULus, GL Input/output/battery Signal Screw connection 0,5/16 0,5/6 0,5/16 0,5/4 26/6 26/12 10 8 1,2 … 1,5 0,5…0,6 CE, TÜV; Pending: cURus, cULus, GL Input/output/battery Signal Screw connection 0,5/16 0,5/6 0,5/16 0,5/4 26/6 26/12 10 8 1,2 … 1,5 0,5…0,6 Type CP DC UPS 24 V 20 A/10 A Qty. 1 Order No. 1370050010 Type CP DC UPS 24 V 40 A Qty. 1 Order No. 1370040010 B.5 Uninterruptible power supplies (UPS) Battery modules •Maintenence-free lead-acid batteries from 3.4 Ah to 17 Ah •Integrated temperature sensor for optimal battery charging •Integrated fuse for reliable activation •Capacity up to 40 A / 30 min or 1 A / 30 hrs •Robust metal housing for wall mounting CP A BATTERY 24V DC 3,4 Ah B CP A BATTERY 24V DC 7,2 Ah % Technical data % Rated voltage Nominal capacity Max. charging current at 0.15 CA Fuse (ATO flat blade fuse max. 80 V DC) Buffer time 24 V DC 3,4 Ah 0,51 A 25 A 11,3 min @ 10 A 5 min @ 20 A Max. output current Parallel connection option Series switching capability Temperature sensor General data Battery type (maintenance-free battery) Battery type Panasonic Lifetime in years (application-dependent) Ambient temperature Storage temperature Latest commissioning in months Max. perm. air humidity Class of protection Protection degree Vibration mounting rail assembly/wall mounting acc. to IEC 68-2-6 Shock mounting rail assembly/wall mounting acc. to IEC 68-2-27 Height x width x depth Weight Approvals Connection data (input/output, signal) Screw connection Wire cross-section, rigid mm² (min./max.) Wire cross-section, flexible mm² (min./max.) Wire cross-section, AWG/kcmil (min./max.) Tightening torque range (Nm) 25 A Yes, max. 2 No NTC 8 kΩ 24 V DC 7,2 Ah 1,8 A 2 x 25 A 26,5 min @ 10 A 11,5 min @ 20 A 5 min @ 30 A 50 A Yes, max. 2 No NTC 8 kΩ Valve Regulated Lead Acid (VRLA)- Absorbed Glass Mat (AGM) UP-RW1220P 6…9 @ 20 °C 0 °C...+40 °C –15 °C…+40 °C 9 5…95 % III IP 20 0.7 g / 0.7 g 30 g 144 / 108 / 126 mm 3,6 kg CE, TÜV Input/output/battery Signal Pluggable 0,2/6 0,2/1,5 0,25/6 0,2/1,5 24/10 28/16 0,5…0,6 0,2…0,25 Valve Regulated Lead Acid (VRLA)- Absorbed Glass Mat (AGM) LC-R127R2PG 6…9 @ 20 °C 0 °C...+40 °C –15 °C…+40 °C 9 5…95 % III IP 20 – / 0.7 g 30 g 155 / 162 / 126 mm 5,9 kg CE, TÜV Input/output/battery Signal Pluggable 0,2/6 0,2/1,5 0,25/6 0,2/1,5 24/10 28/16 0,5…0,6 0,2…0,25 Type CP A BATTERY 24V DC 3,4 Ah Type CP A BATTERY 24V DC 7,2 Ah Ordering data Qty. 1 Order No. 1251070000 Qty. 1 Order No. 1251080000 6HQVRU ' + 17& : B.6 3( 1366860000 – 2013 CP A BATTERY 24V DC 12 Ah Rated voltage Nominal capacity Max. charging current at 0.15 CA Fuse (ATO flat blade fuse max. 80 V DC) Buffer time Max. output current Parallel connection option Series switching capability Temperature sensor General data Battery type (maintenance-free battery) Battery type Panasonic Lifetime in years (application-dependent) Ambient temperature Storage temperature Latest commissioning in months Max. perm. air humidity Class of protection Protection degree Vibration mounting rail assembly/wall mounting acc. to IEC 68-2-6 Shock mounting rail assembly/wall mounting acc. to IEC 68-2-27 Height x width x depth Weight Approvals Connection data (input/output, signal) Screw connection Wire cross-section, rigid mm² (min./max.) Wire cross-section, flexible mm² (min./max.) Wire cross-section, AWG/kcmil (min./max.) Tightening torque range (Nm) Ordering data %XIIHUWLPHVRXWSXWYROWDJHFXUYH %XIIHUWLPHVQ>PLQ@ CP A BATTERY 24V DC 17 Ah % Technical data Uninterruptible power supplies (UPS) Battery modules B % 24 V DC 12 Ah 1,8 A 2 x 25 A 51 min @ 10 A 22,7 min @ 20 A 9,2 min @ 30 A 50 A Yes, max. 2 No NTC 8 kΩ 24 V DC 17 Ah 2,55 A 2 x 25 A 81 min @ 10 A 34,2 min @ 20 A 13,5 min @ 30 A 50 A Yes, max. 2 No NTC 8 kΩ Valve Regulated Lead Acid (VRLA)- Absorbed Glass Mat (AGM) LC-RA1212PG 6…9 @ 20 °C 0 °C...+40 °C –15 °C…+40 °C 9 5…95 % III IP 20 – / 0.7 g 30 g 155 / 229 / 126 mm 9,2 kg CE, TÜV Input/output/battery Signal Pluggable 0,2/6 0,2/1,5 0,25/6 0,2/1,5 24/10 28/16 0,5…0,6 0,2…0,25 Valve Regulated Lead Acid (VRLA)- Absorbed Glass Mat (AGM) LC-XD1217APG 10…12 @ 20 °C 0 °C...+40 °C –15 °C…+40 °C 9 5…95 % III IP 20 – / 0.7 g 30 g 178 / 232 / 160 mm 13,4 kg CE, TÜV Input/output/battery Signal Pluggable 0,2/6 0,2/1,5 0,25/6 0,2/1,5 24/10 28/16 0,5…0,6 0,2…0,25 Type CP A BATTERY 24V DC 12 Ah Type CP A BATTERY 24V DC 17 Ah Qty. 1 Order No. 1251090000 Qty. 1 Order No. 1251110000 &3$%DWWHU\9'&$K &3$%DWWHU\9'&$K &3$%DWWHU\9'&$K &3$%DWWHU\9'&$K &3$%DWWHU\9'&$K 1366860000 – 2013 2XWSXWYROWDJH>$@ B.7 Uninterruptible power supplies (UPS) Buffer modules •Maintenance-free UPS on capacitor basis with a capacity to support 20 A / 260 ms •Parallel switching to increase the output current or support time •Status notification via LED and relay contact CP DC Buffer 24V 20A B % {\ Technical data Input Input voltage Input current Max. approved input current Surge protection Output Output voltage Output current Parallel connection option Overload protection Surge protection Status relay (max. load) 24 V DC (22,5…30 V DC) 0…22 A Max. 22 A 35 V DC suppressor diode 24 V DC 20 A, max. 22 A Yes, without diode module ≥ 22 A (Only at discharge) 31…34 V (Only at discharge) Input voltage OK (30 V AC/DC 2 A) Operational (24 V AC/DC 300 mA) Display Operational General data Efficiency Insulation voltage input/output Storage medium Buffer times MTBF Ambient temperature Storage temperature Max. perm. air humidity Height x width x depth Standards applied EMC Weight Approvals Connection data Conductor connection system Wire cross-section mm² (nominal/min./max.) LED green: ready mm Ordering data 95 % 1 kV Internal condenser 260 ms bei 20 A, 6 s at 1 A > 500,000 hours acc. to IEC 1709 –25 °C…+70 °C –40 °C…+85 °C 5…95 % 130 / 66 / 150 EN50178, EN60950 EN55011, EN55022, EN55024, EN61000-6-2,-3,-4 1,15 kg CE, TÜV, cURus, cULus Input Output Signal Screw connection 10/0,3/16 10/0,3/16 4/0,13/6 Type CP DC Buffer 24V 20A Qty. 1 Order No. 1251220000 Block diagram D Input + – Output + – H Ready – Fail W B.8 1366860000 – 2013 Fuse protection for 24 V DC circuits Contents Fuse protection for 24 V DC circuits Fuse protection for 24 V DC circuits Overview C.2 WAVEGUARD C.4 C 1366860000 – 2013 C.1 Fuse protection for 24 V DC circuits Fuse protection for 24 V DC circuits – Overview Fuse protection A 24-V DC control voltage has become the standard in the automation industry. Selective fuse protection is often used when the power is being supplied by PLC-guided controllers. It divides the total load into separate, logically connected safety circuits. For example, the CPU, actuators and sensors can be separated in the load circuits. This selective load protection helps to decrease facility downtime and also to simplify troubleshooting. When a disruption (short circuit) occurs on a standard protective system, the entire power supply is interrupted. In a system using selective fuse protection, only the fuse in the one disrupted load circuit is triggered. If the fuse is triggered quick enough so that other loads (and particularly the CPU) can continue functioning properly, then various control algorithms can be used to deal with the disruption. It is then possible to shut down the facility in an orderly and controlled fashion. C A fundamental problem when using ordinary fuses is that they take a relatively long time to trigger. Usually, a C.2 switched-mode power supply is already well over the surgecurrent limit (typically 120 % of Inom) before its fuse triggers. Ordinary fuses are therefore not suitable for constructing a selective fuse protective system. Such systems present DC fuses with special challenges. They must be able to switch off quickly enough but they must also be able to tolerate the start-up surge currents from consumer loads. Weidmüller‘s electronic fuses, from our established WAVEGUARD line, are the answer to both of these challenges: they are quick acting but can also tolerate start-up currents. You can easily implement selective load protection using our WAVEGUARD models. In addition, Weidmüller‘s electronic fuses feature a floating alarm contact and a reset input. This allows a PLC controller to query the status of the fuse or to perform an automated reset after troubleshooting. This provides you with a convenient method for remotely maintaining a complex facility. As a result, you save both time and money. 1366860000 – 2013 Fuse protection for 24 V DC circuits Fuse protection for 24 V DC circuits – Overview Resetting The WAVEGUARD family can be reset manually or by using an external signal. They can be reset remotely by simply applying a 24 V signal pulse on the reset input. The reset occurs on the falling edge of the signal. Note: A cyclical automatic reset is not permitted and can lead to a malfunction. Block diagram WAVEGUARD INPUT 24 V Reset (8) (1) (9) gn 24 V fail re (2) 0V OUTPUT (7) (3) C NC contact 50 Vuc/0.05A Signalling A red LED displays when the electronic fuse has been triggered. An alert is also sent out over a floating alarm contact. A green LED signals that the unit is switched on. The alarm contact uses an NC contact. WaveGuard 1366860000 – 2013 C.3 Fuse protection for 24 V DC circuits WAVEGUARD 24 V DC 1.6 A 24 V DC 3.15 A D H INPUT 24 V Reset C 0V W (8) (1 ) (9 ) gn rt OUTPUT 24 V fail (7 ) (2 ) (3 ) NC contact 50 V uc /0.05 A Current (A ) Current (A ) 20 18 16 14 12 10 8 6 4 2 0 24 22 20 18 16 14 12 10 8 6 4 2 0 Time ( m s ) 0 20 40 60 80 10 0 12 0 14 0 T i m e ( m s) 0 10 15 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0 16 0 Technical data Input Rated control voltage Rated current Reset Output Status relay / CO contact Signalling delay General data Ambient temperature Storage temperature Status indication Standards EMC standards Sliding switch Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note mm² 24 V DC 1.6 A Impulse > 100 ms +24 V, falling edge ON 24 V DC 3.15 A Impulse > 100 ms +24 V, falling edge ON NC contact, max. 50 V / 0.05 A; for low voltage only! 3.5 ms typ. NC contact, max. 50 V / 0.05 A; for low voltage only! 3.5 ms typ. 0...+55 °C -20 °C...+85 °C LED green: OK, LED red: tripped DIN EN 50178 EN 55011, EN 61000-6-1, 2, 4 OFF - wait 10 s - ON; on / off cCSAus; CE; cURus; GOSTME25 0...+55 °C -20 °C...+85 °C LED green: OK, LED red: tripped DIN EN 50178 EN 55011, EN 61000-6-1, 2, 4 OFF - wait 10 s - ON; on / off cCSAus; CE; cURus; GOSTME25 2.5 / 0.5 / 2.5 1.5 / 0.5 / 2.5 92.4 / 22.5 / 72 92.4 / 22.5 / 72 Periodic auto-reset not permitted; Tu=23 °C,Tension single module Screw connection clamp connection 2.5 / 0.5 / 2.5 1.5 / 0.5 / 2.5 92.4 / 22.5 / 72 92.4 / 22.5 / 72 Periodic auto-reset not permitted; Tu=23 °C,Tension single module Screw connection clamp connection Type WGS 24Vdc 1,6A WGZ 24Vdc 1,6A Type WGS 24Vdc 3,15A WGZ 24Vdc 3,15A Ordering data Screw connection Tension-clamp connection Qty. 1 1 Order No. 8618890000 8621040000 Qty. 1 1 Order No. 8618910000 8621030000 Note Accessories Note C.4 Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5N/2 Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5N/2 1366860000 – 2013 24 V DC 6.3 A Fuse protection for 24 V DC circuits WAVEGUARD 24 V DC 8 A D H INPUT 24 V Reset 0V W (8) (1 ) (9 ) gn rt 24 V fail (7 ) (2 ) (3 ) Current (A ) Current (A ) OUTPUT NC contact 50 V uc /0.05 A 26 24 22 20 18 16 14 12 10 8 6 4 Time (ms) 0 10 15 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 65 60 55 50 45 40 35 30 25 20 15 10 5 C Time (ms) 0 5 10 15 20 25 30 35 40 45 50 Technical data Input Rated control voltage Rated current Reset Output Status relay / CO contact Signalling delay General data Ambient temperature Storage temperature Status indication Standards EMC standards Sliding switch Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note mm² 24 V DC 6.3 A Impulse > 100 ms +24 V, falling edge ON 24 V DC 8A Impulse > 100 ms +24 V, falling edge ON NC contact, max. 50 V / 0.05 A; for low voltage only! 3.5 ms typ. NC contact, max. 50 V / 0.05 A; for low voltage only! 3.5 ms typ. 0...+55 °C -20 °C...+85 °C LED green: OK, LED red: tripped DIN EN 50178 EN 55011, EN 61000-6-1, 2, 4 OFF - wait 10 s - ON; on / off cCSAus; CE; cURus; GOSTME25 0...+55 °C -20 °C...+85 °C LED green: OK, LED red: tripped DIN EN 50178 EN 55011, EN 61000-6-1, 2, 4 OFF - wait 10 s - ON; on / off cCSAus; CE; cURus; GOSTME25 2.5 / 0.5 / 2.5 1.5 / 0.5 / 2.5 92.4 / 22.5 / 72 92.4 / 22.5 / 72 Periodic auto-reset not permitted; Tu=23 °C,Tension single module Screw connection clamp connection 2.5 / 0.5 / 2.5 1.5 / 0.5 / 2.5 92.4 / 22.5 / 72 92.4 / 22.5 / 72 Periodic auto-reset not permitted; Tu=23 °C,Tension single module Screw connection clamp connection Type WGS 24Vdc 6,3A WGZ 24Vdc 6,3A Type WGS 24Vdc 8,0A WGZ 24VDC 8,0A Ordering data Screw connection Tension-clamp connection Qty. 1 1 Order No. 8618930000 8621020000 Qty. 1 1 Order No. 8618940000 8621010000 Note Accessories Note 1366860000 – 2013 Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5N/2 Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5N/2 C.5 Fuse protection for 24 V DC circuits WAVEGUARD 24 V DC 0.5...5 A D H INPUT 24 V Reset C 0V W (8) (1 ) (9 ) gn rt OUTPUT 24 V fail (7 ) (2 ) (3 ) NC contact 50 V uc /0.05 A Technical data Derating curve Dynamic tripping characteristic Input Rated control voltage Rated current Reset Output Status relay / CO contact Signalling delay General data Ambient temperature Storage temperature Status indication Standards EMC standards Sliding switch Approvals 24 V DC 0.5...5 A adjustable Impulse > 100 ms +24 V, falling edge ON Tripping current: 0.5 A Tripping current (A) 25 20 15 10 5 0 0 20 40 NC contact, max. 50 V / 0.05 A; for low voltage only! 3.5 ms typ. 0...+55 °C -20 °C...+85 °C LED green: OK, LED red: tripped DIN EN 50178 EN 55011, EN 61000-6-1, 2, 4 OFF - wait 10 s - ON; on / off cCSAus; CE; cURus; GOSTME25 mm² 80 100 120 140 60 80 100 120 140 Time (ms) Tripping current: 5.0 A Tripping current (A) 25 20 15 10 5 0 0 20 40 Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 60 Time (ms) 2.5 / 0.5 / 2.5 1.5 / 0.5 / 2.5 92.4 / 22.5 / 72 92.4 / 22.5 / 72 Periodic auto-reset not permitted; Tu=23 °C,Tension single module Screw connection clamp connection Ordering data Screw connection Tension-clamp connection Type WGS 24Vdc 0.5...5A WGZ 24Vdc 0.5...5A Qty. 1 1 Order No. 8710270000 8727630000 Note Accessories Note C.6 Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5N/2 1366860000 – 2013 Unregulated power supplies Contents Unregulated power supplies Unregulated power supplies Overview D.2 compactPower D.4 D 1366860000 – 2013 D.1 Unregulated power supplies Unregulated power supplies – Overview Unregulated power supplies – compactPower D D.2 Compact power supply units are important links in the power supplies for controllers. They are used where processes or control voltages are required that vary from the mains voltage. Transformers provide the electrical isolation between the input circuit and the output circuit. The minimum requirement (to VDE 0550) is 2,000 V. Screw terminals secure the input-side connection to the mains. The single-phase devices are rated for a nominal voltage of ∼230 ± ∼15 V, or ∼400 V ± ∼15 V, 50/60 Hz, the 3-phase devices for 3 x 400 V ± 5 %. The secondary DC voltage from the transformer is conducted to a bridge rectifier where it is rectified. The pulsating DC voltage is then fed from the rectifier and filtered to a low residual ripple by means of an electrolytic capacitor. This DC voltage is then fed to the output terminal. These are designed as pluggable screw terminals. A varistor is integrated in the output circuitry to attenuate voltage peaks. The operating status is indicated by means of a green LED via the output circuit. Devices with 600 W and higher are equipped with a fan. Single-phase unregulated power supplies Three-phase unregulated power supplies 1366860000 – 2013 Unregulated power supplies Unregulated power supplies – Overview Well-balanced spectrum for optimum economy Block diagram for single-phase devices CP NT The output currents of these practical products are defined by way of two ambient temperatures. Size selection is based on the maximum effectiveness of the components. INPUT +15 V 0V –15 V Adapted to standard voltages in accordance with IEC 38 400 V PE By choosing the appropriate terminals, the ± 15 V tapping capability allows the single-phase devices to be connected to six different nominal AC voltages: 215, 230, 245, 385, 400, 415 V. The ± 5 % tapping capability allows the 3-phase devices to be connected to three different nominal voltages: 380, 400, 415 V. Reliable short-circuit and overload protection Integrated on the secondary side in device sizes up to CP NT 192 W, the FKS fuse protects against overloads and shortcircuits. For the devices CP NT 264 W and CP NT 432 W, this protection is achieved by means of a thermostatic switch built into the transformer. 230 V . . . . . D Block diagram for 3-phase devices CP NT3 250 / 400 / 500 W INPUT +5% 400 V –5% +5% 400 V –5% +5% 400 V –5% 3x OUTPUT + + 24V DC = 130° PE - ~ Block diagram for 3-phase devices CP NT3 600 / 750 / 1.000 W Easy mounting Keyhole assembly simplifies mounting and saves time. A snap-on fixing attachment for 35 mm DIN rails is available as an accessory for single-phase devices up to 144 W. Simply plugged into the device and secured with two screws, it ensures easiest possible mounting! OUTPUT + + 24V DC INPUT +5% 400 V –5% +5% 400 V –5% +5% 400 V –5% 3x = 130° M PE ~ OUTPUT + + 24V DC 0V Fail Transformers, vacuum-impregnated, painted black • No humming • Moisture cannot ingress into the windings • Windings mechanically secured • Improved heat dissipation from the windings • Good heat dissipation Unregulated power supplies single-phase Unregulated power supplies 3-phase 1366860000 – 2013 D.3 Unregulated power supplies compactPower compactPower single-phase CP NT 36 CP NT 72 INPUT OUTPUT +15V 0V -15V 230V 400V PE D . . . . INPUT + + 24VDC +15V 0V -15V - 230V 400V PE . OUTPUT + + 24VDC . . . . . Technical data Input Input voltage Input current Input frequency No-load input current Ext. Back-up fuse Output Output voltage Output current at 40°C Output current at 55°C Output power Max. residual ripple Fusing Protective circuit, load side Insulation coordination (EN 50178) Electric shock protection Insulation strength Insulation class Protection degree Class of protection General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Mounting position, installation notice Installation advice Status indication Height x width x depth Weight Standards EMC standards Approvals Dimensions Clamping range (nominal / min. / max.) mm² 230 V/ 400 V ±15 V 0.35 A/ 0.2 A 50/ 60 Hz 0.1 A / 0.06 A 0.63 A / 0.315 A time-lag 230 V/ 400 V ±15 V 0.56 A/ 0.32 A 50/ 60 Hz 0.13 A / 0.08 A 0.1 A / 0.63 A time-lag 24 V DC SELV 1.5 A 1A 36 W <5% 3 A time-lag flat cable-lug fuse Varistor 24 V DC SELV 3A 2.5 A 72 W <5% 7.5 A time-lag flat cable-lug fuse Varistor acc. to BGV A3 4 kV B IP 20 I acc. to BGV A3 4 kV B IP 20 I -20...+55 °C -20 °C...+80 °C 80% Arbitrary, horizontally, on terminal rail TS 35 Direct mounting, TS 35 with clip-on plate Green LED 123 / 78 / 68 mm 1.5 kg DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG EN 61000-6 /-2, -3 CE; cULus; GOSTME25 -20...+55 °C -20 °C...+80 °C 83% Arbitrary, horizontally, on terminal rail TS 35 Direct mounting, TS 35 with clip-on plate Green LED 125 / 84 / 85 mm 2.1 kg DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG EN 61000-6 /-2, -3 CE; cULus; GOSTME25 Input 2.5 / 0.13 / 2.5 Input 2.5 / 0.13 / 2.5 Output 2.5 / 0.5 / 4 Output 2.5 / 0.5 / 4 Note Ordering data Screw connection Type CP NT 36W 24V 1.5A Qty. 1 Order No. 8575260000 Type CP NT 72W 24V 3A Qty. 1 Order No. 8575270000 Note Accessories Note D.4 Clip-in plate for TS35: 8588900000 Clip-in plate for TS35: 8588910000 1366860000 – 2013 compactPower single-phase CP NT 144 CP NT 192 INPUT OUTPUT +15V 0V -15V 230V 400V PE Unregulated power supplies compactPower . . . . INPUT + + 24VDC +15V 0V -15V - 230V 400V PE . OUTPUT + + 24VDC . . . . . D Technical data Input Input voltage Input current Input frequency No-load input current Ext. Back-up fuse Output Output voltage Output current at 40°C Output current at 55°C Output power Max. residual ripple Fusing Protective circuit, load side Insulation coordination (EN 50178) Electric shock protection Insulation strength Insulation class Protection degree Class of protection General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Mounting position, installation notice Installation advice Status indication Height x width x depth Weight Standards EMC standards Approvals Dimensions Clamping range (nominal / min. / max.) mm² 230 V/ 400 V ±15 V 0.95 A/ 0.55 A 50/ 60 Hz 0.33 A / 0.19 A 1.6 A / 1.0 A time-lag 230 V/ 400 V ±15 V 1.3 A/ 0.7 A 50/ 60 Hz 0.3 A / 0.16 A 2.0 A / 1.25 A time-lag 24 V DC SELV 6A 5A 144 W <5% 10 A time-lag flat cable-lug fuse Varistor 24 V DC SELV 8A 7A 192 W <5% 15 A time-lag flat cable-lug fuse Varistor acc. to BGV A3 4 kV B IP 20 I acc. to BGV A3 4 kV B IP 20 I -20...+55 °C -20 °C...+80 °C 88% Arbitrary, horizontally, on terminal rail TS 35 Direct mounting, TS 35 with clip-on plate Green LED 135 / 96 / 92 mm 3.1 kg DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG EN 61000-6 /-2, -3 CE; cULus; GOSTME25 -20...+55 °C -20 °C...+80 °C 90% Input 2.5 / 0.13 / 2.5 Input 2.5 / 0.13 / 2.5 Direct mounting Green LED 145 / 105 / 105 mm 4.3 kg DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG EN 61000-6 /-2, -3 CE; cULus; GOSTME25 Output 2.5 / 0.5 / 4 Output 2.5 / 0.5 / 4 Note Ordering data Screw connection Type CP NT 144W 24V 6A Qty. 1 Order No. 8575280000 Type CP NT 192W 24V 8A Qty. 1 Order No. 8575300000 Note Accessories Note 1366860000 – 2013 Clip-in plate for TS35: 8588920000 D.5 Unregulated power supplies compactPower compactPower single-phase CP NT 264 CP NT 432 INPUT OUTPUT +15V 0V -15V 230V 400V PE D . . . . INPUT + + 24VDC +15V 0V -15V - 230V 400V PE . OUTPUT + + 24VDC . . . . . Technical data Input Input voltage Input current Input frequency No-load input current Ext. Back-up fuse Output Output voltage Output current at 40°C Output current at 55°C Output power Max. residual ripple Fusing Protective circuit, load side Insulation coordination (EN 50178) Electric shock protection Insulation strength Insulation class Protection degree Class of protection General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Installation advice Status indication Height x width x depth Weight Standards EMC standards Approvals Dimensions Clamping range (nominal / min. / max.) mm² 230 V/ 400 V ±15 V 1.8 A/ 1 A 50/ 60 Hz 0.5 A / 0.28 A 3.15 A / 1.6 A time-lag 230 V/ 400 V ±15 V 2.5 A/ 1.3 A 50/ 60 Hz 0.54 A / 0.31 A 4.0 A / 2.0 A time-lag 24 V DC SELV 11 A 10 A 264 W <5% Thermostatic switch Varistor 24 V DC SELV 18 A 15 A 432 W <5% Thermostatic switch Varistor acc. to BGV A3 4 kV B IP 20 I acc. to BGV A3 4 kV B IP 20 I -20...+55 °C -20 °C...+80 °C 93% Direct mounting Green LED 165 / 120 / 113 mm 6.1 kg DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG EN 61000-6 /-2, -3 CE; cULus; GOSTME25 -20...+55 °C -20 °C...+80 °C 95% Direct mounting Green LED 185 / 135 / 135 mm 9.1 kg DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG EN 61000-6 /-2, -3 CE; cULus; GOSTME25 Input 2.5 / 0.13 / 2.5 Input 2.5 / 0.13 / 2.5 Output 2.5 / 0.5 / 4 Output 2.5 / 0.5 / 4 Note Ordering data Screw connection Type CP NT 264W 24V 11A Qty. 1 Order No. 8575310000 Type CP NT 432W 24V 18A Qty. 1 Order No. 8575320000 Note Accessories Note D.6 1366860000 – 2013 compactPower 3-phase CP NT3 250 Unregulated power supplies compactPower CP NT3 400 INPUT +5% 400V -5% +5% 400V - 5% +5% 400V -5% OUTPUT 3x = 130° PE ~ INPUT + + 24VDC - +5% 400V -5% +5% 400V - 5% +5% 400V -5% OUTPUT 3x = 130° PE ~ + + 24VDC - D Technical data Input Input voltage Input current Input frequency No-load input current Input fuse Ext. Back-up fuse Output Output voltage Output current at 40°C / 60°C Output power Max. residual ripple Fusing Protective circuit, load side Insulation coordination (EN 50178) Electric shock protection Insulation strength Insulation class Protection degree Class of protection General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Installation advice Fan signal Height x width x depth Status indication Weight Standards EMC standards Approvals Dimensions Clamping range (nominal / min. / max.) mm² Note 3 x 400 V ±5 % 0.5 A 50/ 60 Hz 0.1 A 3 x primary thermostatic switch 3 x 1.0 A time-lag 3 x 400 V ±5 % 0.75 A 50/ 60 Hz 0.11 A 3 x primary thermostatic switch 3 x 1.2 A time-lag 24 V DC SELV 11 A / 10 A 250 W <2% External 10 A time-lag Varistor 24 V DC SELV 18 A / 16 A 400 W <2% External 16 / 18 A slo-blow Varistor acc. to BGV A3 4 kV B IP 20 I acc. to BGV A3 4 kV B IP 20 I -20...+60 °C -20 °C...+80 °C 76% Direct mounting No integrated fan 192 / 84 / 185 mm Green LED 4.7 kg DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG EN 61000-6 /-2, -3 cCSAus; CE; GOSTME25 -20...+60 °C -20 °C...+80 °C 77% Direct mounting No integrated fan 213 / 88 / 220 mm Green LED 6.9 kg DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG EN 61000-6 /-2, -3 cCSAus; CE; GOSTME25 Input 2.5 / 0.5 / 2.5 Input 2.5 / 0.5 / 2.5 Output 6 / 0.5 / 6 Condensation not allowed Output 6 / 0.5 / 6 Condensation not allowed Ordering data Screw connection Type CP NT3 250W 24V 10A Qty. 1 Order No. 8628620000 Type CP NT3 400W 24V 15A Qty. 1 Order No. 8628630000 Note Accessories Note 1366860000 – 2013 D.7 Unregulated power supplies compactPower compactPower 3-phase CP NT3 500 CP NT3 600 INPUT +5% 400V -5% +5% 400V - 5% +5% 400V -5% OUTPUT 3x = 130° PE ~ D INPUT + + 24VDC - +5% 400V -5% +5% 400V -5% +5% 400V -5% OUTPUT 3x = 130° M PE + + 24VDC 0V Fail ~ Technical data Input Input voltage Input current Input frequency No-load input current Input fuse Ext. Back-up fuse Output Output voltage Output current at 40°C / 60°C Output power Max. residual ripple Fusing Protective circuit, load side Insulation coordination (EN 50178) Electric shock protection Insulation strength Insulation class Protection degree Class of protection General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Installation advice Fan signal Height x width x depth Status indication Weight Standards EMC standards Approvals Dimensions Clamping range (nominal / min. / max.) mm² Note 3 x 400 V ±5 % 0.9 A 50/ 60 Hz 0.13 A 3 x primary thermostatic switch 3 x 1.6 A time-lag 3 x 400 V ±5 % 1.2 A 50/ 60 Hz 0.15 A 3 x primary thermostatic switch 3 x 2 A time-lag 24 V DC SELV 22 A / 20 A 500 W <2% External 20 / 22 A slo-blow Varistor 24 V DC SELV 26 A / 25 A 600 W <2% External 25 / 26 A slo-blow Varistor acc. to BGV A3 4 kV B IP 20 I acc. to BGV A3 4 kV B IP 20 I -20...+60 °C -20 °C...+80 °C 78% Direct mounting No integrated fan 215 / 108 / 220 mm Green LED 10 kg DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG EN 61000-6 /-2, -3 cCSAus; CE; cULus; GOSTME25 -20...+60 °C -20 °C...+80 °C 78% Direct mounting Open collector <30 V/ <5 mA during interference 212 / 108 / 230 mm Green LED 11 kg DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG EN 61000-6 /-2, -3 cCSAus; CE; GOSTME25 Input 2.5 / 0.5 / 2.5 Input 2.5 / 0.5 / 2.5 Output 6 / 0.5 / 6 Condensation not allowed Output 6 / 0.5 / 6 Condensation not allowed Ordering data Screw connection Type CP NT3 500W 24V 20A Qty. 1 Order No. 8628650000 Type CP NT3 600W 24V 25A Qty. 1 Order No. 8628660000 Note Accessories Note D.8 1366860000 – 2013 compactPower 3-phase CP NT3 750 Unregulated power supplies compactPower CP NT3 1000 INPUT +5% 400V -5% +5% 400V -5% +5% 400V -5% OUTPUT 3x = 130° M PE 0V Fail ~ INPUT + + 24VDC +5% 400V -5% +5% 400V -5% +5% 400V -5% OUTPUT 3x = 130° M PE + + 24VDC 0V Fail ~ D Technical data Input Input voltage Input current Input frequency No-load input current Input fuse Ext. Back-up fuse Output Output voltage Output current at 40°C / 60°C Output power Max. residual ripple Fusing Protective circuit, load side Insulation coordination (EN 50178) Electric shock protection Insulation strength Insulation class Protection degree Class of protection General data Ambient temperature (operational) Storage temperature Degree of efficiency at max. load Installation advice Fan signal Height x width x depth Status indication Weight Standards EMC standards Approvals Dimensions Clamping range (nominal / min. / max.) mm² Note 3 x 400 V ±5 % 1.4 A 50/ 60 Hz 0.16 A 3 x primary thermostatic switch 3 x 2.5 A time-lag 3 x 400 V ±5 % 1.8 A 50/ 60 Hz 0.14 A 3 x primary thermostatic switch 3 x 3.15 A time-lag 24 V DC SELV 32 A / 30 A 750 W <2% External 30 / 32 A slo-blow Varistor 24 V DC SELV 42 A / 40 A 1000 W <2% External 40 / 42 A slo-blow Varistor acc. to BGV A3 4 kV B IP 20 I acc. to BGV A3 4 kV B IP 20 I -20...+60 °C -20 °C...+80 °C 77% Direct mounting Open collector <30 V/ <5 mA during interference 255 / 121 / 270 mm Green LED 14 kg DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG EN 61000-6 /-2, -3 cCSAus; CE; GOSTME25 -20...+60 °C -20 °C...+80 °C 77% Direct mounting Open collector <30 V/ <5 mA during interference 275 / 122 / 280 mm Green LED 18 kg DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG EN 61000-6 /-2, -3 cCSAus; CE; GOSTME25 Input 2.5 / 0.5 / 2.5 Input 2.5 / 0.5 / 2.5 Output 6 / 0.5 / 6 Condensation not allowed Output 10 / 0.5 / 10 Condensation not allowed Ordering data Screw connection Type CP NT3 750W 24V 30A Qty. 1 Order No. 8628670000 Type CP NT3 1000W 24V 40A Qty. 1 Order No. 8628680000 Note Accessories Note 1366860000 – 2013 D.9 D D.10 1366860000 – 2013 Unregulated power supplies IP 65 switched-mode power supply / Electrical cabinet socket outlet Contents IP 65 switched-mode power supply / Electrical cabinet socket outlet IP 65 switched-mode power supply / Electrical cabinet socket outlet 1366860000 – 2013 Overview E.2 FieldPower® switched mode power units E.6 FieldPower® Control: the modular base E.8 Housings E.10 Connection principle E.13 Contact modules and plug connectors E.14 Help with project planning E.20 Drilling template E.23 Electrical cabinet socket outlet E.24 E E.1 IP 65 switched-mode power supply / Electrical cabinet socket outlet Overview FieldPower® DC network With decentralised fuse protection for spur lines The demand for 24-V current in facilities has grown as productivity increases. Modular and decentralised topologies have long been firmly established. Yet the auxiliary power is still often being generated in the electrical cabinet and transmitted with significant power loss to the field using long cables. Standard compliant fuse protection for these lines is thus repeatedly ignored since such protection is difficult to implement on such long stretches. The new FieldPower® switch-mode power supply creates and protects the current supply directly at the consumer site. Its many features make it possible to operate highly dependable and energy efficient DC power networks. E E.2 FieldPower® power bus system Product Information Decentralised Automation The full line of FieldPower® products is listed in our product information. (Order No.1355570000) 1366860000 – 2013 IP 65 switched-mode power supply / Electrical cabinet socket outlet Overview Voltage stability and supply reliability Actuating variable and load limit 24 V 24.25 23 23.75 V U/V More than just a power supply This power-bus-compatible power supply unit does not trigger the 400-V group protective device when reacting to load current peaks. In addition to the power supply unit, the FieldPower® Terminal can also be used for quick and error-free supply to other 400-V consumer loads. 23.25 V ≤ 300 ms 2 Extended application range The FieldPower® switch-mode power supply can be operated in practically any installed position in temperatures ranging from –30 to 50 °C. It can even be used in refrigerated warehouses. Power boost for branch fuse protection Rail-mounted fuse protection for branches (spurs) can be installed into the FieldPower® power supply housing. The power boost from one or more power supplies can selectively trip the fuse after a short circuit. Highly reliable power supply The power supply unit functions even if there is a phase outage. A power boost (2x IN for 300 ms) is available for start-up and load currents. A high voltage stability can be achieved especially when implementing multiple feeds with a load balancing mechanism. 24 V DC 400 V AC 1366860000 – 2013 Simple AC and DC are handled identically. The wire is positioned and contact is established with a simple turning movement. The 5-pin DC contact module has two 24 V plus GND for a permanent and safetycompliant power supply, or for minimising voltage drops with two parallel 6-mm² wire each. 1 0 2.5 5 5.3 7.5 10 12.5 E I/A Loadshare Bus When using multiple power feeds in decentralised 24-V DC structures, different loads are placed on the individual power supply units. Overloads or even outages can occur as a result. The FieldPower® switchmode power supplies feature passive and active load balancing mechanisms. An actuating variable is used to reduce the voltage as the load increases, so that the neighbouring components are supported more strongly. If a power supply unit exceeds its rated current, the voltage on the load limit is reduced until the other power supplies assume this load. Even when in this operational state, the voltage remains at a high level. Complete load balancing is achieved with the point-to-point connections of all load share bus ports. DC-power system with FieldPower® switched-mode power supply units DC power is distributed in parallel with the 400 V power bus. A uniform voltage level in the DC distribution (even when using wires with reduced cross-sections) is made possible by multiple parallel-fed power supply units with high IP protection. E.3 IP 65 switched-mode power supply / Electrical cabinet socket outlet Overview FieldPower® Control Decentralised functional box on the power bus FieldPower® Control features decentralised and modular functional components with high IP protection, using the ideal wire connection technology for AC and DC power supplies. The FieldPower® power distributor (with IP 54/65) can function as a decentralised switch box by adding terminals, electronics housings and switching and protective units. Many parts of factory automation can thus be decentralised using an arrangement of application specific modules. Simple project planning, quick installation, speedy assembly and good extensibility: these are just some of the advantages that FieldPower® Control provides for users. For further information, please visit www.weidmueller.com/int/Fieldpower_control E E.4 1366860000 – 2013 IP 65 switched-mode power supply / Electrical cabinet socket outlet Overview Modular components FieldPower® terminals or a mounting rail can be placed as needed in the lower section in order to fit the needs of the individual application. Retractable seals allow pluggable cables to be inserted quickly. Application specific solutions Weidmüller offers not only individual components but also complete, custom-fit functional units. Add-on to lid Support pegs in the lid help when attaching mounting plates or rails. The lids also provide plenty of space for attaching add-on devices or electronic circuit boards. Variable fastening mechanisms The mounting rail provides 54 mm of installation width and can be used at two heights. This creates space for wires under the mounting rail. E Such units include switching devices, electronic components, terminal strips, connecting plugs, hinged lids and heat sinks. Weidmüller can also customise the internal wiring and the assembly of the connecting cables to fit customer needs. Expanded voltage and current ranges A variety of applications can be implemented with the help of the FieldPower® Terminals in the AC and DC versions up to 800 V/41 A. 3∼, N, PE 2 x DC, GND 40,0 35,0 Pvzul [W] 30,0 for outer Tu 25 °C 25,5 W 25,0 20,0 for outer Tu 35 °C 20,1 W for outer Tu 45 °C 14,8 W 20,1 W 15,0 14,8 W 14,8 W 10,0 9,7 W 9,7 W 0,0 9,7 W 4,7 W 5,0 0 10 20 Max interior Tu 50 °C 30 4,7 W 40 Outer Tu [°C] Max interior Tu 60 °C 0,0 W 50 Max interior Tu 70 °C 60 70 80 Help with project planning Simple thermal layout using dimensioned drawings is possible (see page E.20) and by specifying the built-in power loss and optimal exploitation of available space. Max interior Tu 80 °C Tu max = Max. permitted device temperature 56 159 1366860000 – 2013 4.35 115.4 Please send requests to [email protected] 7.6 2 46 10 Ø 3.4 Ø 7.8 135 46 6 56 E.5 IP 65 switched-mode power supply / Electrical cabinet socket outlet FieldPower® switched mode power units FieldPower®Box with decentralised switchmode power supply FieldPower® Box 10P SNT FieldPower® Box 10P SNT 4XVG With 4 additional M20 cable glands • FieldPower Box with three-phase 24 V / 5 A switch-mode power supply. • C lose-to-load 24 V power generation and distribution for decentralised DC-systems • R educed voltage drops for copper-optimised installations • More reliable power supply with constant voltage • Improved energy efficiency with minimal transmission-related losses ® L1 L2 L3 PE + AC DC – Basic operation is possible with two phases* E Technical data FieldPower® Box Bemmessungsdaten Rated cross-section Rated voltage / Rated current Rated impulse voltage General data UL 94 flammability class Protection degree Assembly temperature range, min. - max. Ambient temperature (operational) IDC connection clamping capacity - power cable Clamping range, min.-max. Blade size PUSH IN connection clamping capacity - distribution Clamping range, min.-max. Stripping length/Blade size Note 6 mm² 800 V / 41 A 8 kV 6 mm² 800 V / 41 A 8 kV 5VA IP 65 10 °C…40 °C -30 °C…50 °C 5VA IP 65 10 °C…40 °C -30 °C…50 °C 2.5 mm²…6 mm² 0.6 x 3.5 mm 2.5 mm²…6 mm² 0.6 x 3.5 mm 0.75 mm²…6 mm² 14 mm / 0.6 x 3.5 mm 0.75 mm²…6 mm² 14 mm / 0.6 x 3.5 mm Refer to PT6 DC 1126840000 for additional technical clamping specifications. Refer to PT6 DC 1126840000 for additional technical clamping specifications. 400...480 V AC** -15 % / +5 % (3∼, PE) Yes 400...480 V AC** -15 % / +5 % (3∼, PE) Yes 24.25 V DC ± 50 mV (23.5…28.0 V DC) 5 A @ 24 V DC 10 A, t ≤ 300 ms Yes 120 W Input Output Plug-in connector Plug-in connector L1, L2, L3, PE +, +, -, -, COM ,NO 0.5 mm²…4 mm² 0.5 mm²…4 mm² 24.25 V DC ± 50 mV (23.5…28.0 V DC) 5 A @ 24 V DC 10 A, t ≤ 300 ms Yes 120 W Input Output Plug-in connector Plug-in connector L1, L2, L3, PE +, +, -, -, COM ,NO 0.5 mm²…4 mm² 0.5 mm²…4 mm² * No power boost in two-phase mode or in current-limiting mode. ** UL approval is pending. * No power boost in two-phase mode or in current-limiting mode. ** UL approval is pending. Refer to BG SNT PT6 1101940000 for additional technical specifications on the power supply. Refer to BG SNT PT6 1101940000 for additional technical specifications on the power supply. Type FP Box 10P SNT Type FP Box 10P SNT 4XVG Technical data power supply Input data Rated input voltage Input fuse (internal) Output data Rated output voltage Rated output current @ Unom Power boost @ 24 V DC, 0..5A, ED = 10 %, three-phase Short-circuit-proof Output power @ 24 V DC Connection data Type of connection Number of terminals conductor cross-section, min.-max. Note Ordering data Note Qty. 1 Order No. 1132320000 Qty. 1 Order No. 1076510000 Enclosure seals can be ordered separately. Enclosure seals (3xD0, 2xD11, 2xD13, 2xD15) and PTDS 4 connector are included in delivery. PT6 DC 1126840000 Contact element PT6 DC 1126840000 Contact element Accessories Note E.6 1366860000 – 2013 IP 65 switched-mode power supply / Electrical cabinet socket outlet FieldPower® switched mode power units BG SNT PT6 Switch-mode power supply 24 V / 5 A • Three-phase built-in 24 V / 5 A power supply with high degree of efficiency. • E xternal heat sink reduces warming within electrical cabinet. • R esistant to vibration – in compliance with EN 61373 Cat. 1b for decentralised machine switchboxes. •W ide temperature range for versatile use (such as in refrigerated storage areas) L1 L2 L3 PE + AC DC – Basic operation is possible with two phases* E Technical data Input data Rated input voltage AC frequency range AC current consumption Start-up surge current / start-up time Input fuse (internal) Output data Rated output voltage Max. residual ripple, inrush peaks Output deviation Rated output current @ Unenn Power boost @ 24 V DC, 0..5 A, ED = 10%, three-phase Output characteristic curve / current limit Short-circuit-proof Output power @ 24 V DC Mains buffering @ Inenn Efficiency Protection against reverse voltages from the load General data Ambient temperature (operational) Protection class, with PE connection Surge category / Pollution severity MTBF according to IEC 1709 (SN29500) EMC / shock / vibration Noise emission acc. to EN 55022 (class) Noise immunity tests Resistance against vibration and shock Electrical safety Electrical machine equipment For use with electronic equipment Safety extra-low voltage Connection data Type of connection Number of terminals conductor cross-section, min.-max. Note Ordering data Note 400…480 V AC** -15 % / +5 % (3∼, PE) 47 Hz - 63 Hz ∼ 0.4 A @ 400 V AC < 10A @ 400 V AC / < 2 s Yes 24.25 V DC ± 50 mV (23.5…28.0 V DC) < 50 mVSS @ 24 V DC / 5 A 500 mV @ 0…5 A 5 A @ 24 V DC 10 A, t ≤ 300 ms IU, 5.3 A ± 0.2 A Yes 120 W 20 ms @ 400 V AC ∼ 86 % @ 400 V AC ≤ 34 V -30 °C…55 °C* I III / 2 > 500.000 h @ 25 °C A according to EN 61000-6-2 according to EN 61373 Kat. 1b according to EN 60204 according to EN 50178 / VDE 0160 according to SELV: EN 60950 / PELV: EN 60204 Input Output Plug-in connector Plug-in connector L1, L2, L3, PE +, +, -, -, COM ,NO 0.5 mm²…4 mm² 0.5 mm²…4 mm² * No power boost in two-phase mode or in current-limiting mode. ** UL approval is pending. Type BG SNT PT6 Qty. 1 Order No. 1101940000 Assembly accessories are included in delivery. Accessories Note 1366860000 – 2013 * Please refer to the derating curve on page 66 for more details. E.7 IP 65 switched-mode power supply / Electrical cabinet socket outlet FieldPower® Control: The modular base FieldPower® Control: The modular base Standard components Lid and functions Flat lid 1068890000 High lid 1276220000 Lid with maintenance switch 111312000 NEW E Housing and seals Bottom housing 1070140000 Bottom housing with wall feed-through 1272210000 NEW Plug Contacts Single plug L1, N, L2, PE, L3 1952120000 Double plug L1, N, L2, PE, L3 1952130000 Fuse plug L1, N, L2, PE, L3 1961770000 Contact module L1, N, L2, PE, L3 1957620000 AC labelling E.8 1366860000 – 2013 IP 65 switched-mode power supply / Electrical cabinet socket outlet FieldPower® Control: The modular base Flat lid 1122200000 High lid 1121950000 Lid with maintenance switch 8000005211 LED lid lighting 1272220000 NEW Bottom housing 1121980000 Single plug +1, -1, FE, +2, -2 1131730000 Bottom housing with 4 glands 1121990000 Double plug +1, -1, FE, +2, -2 1009990000 Fuse plug +1, -1, FE, +2, -2 1252210000 NEW Contact module +1, -1, FE, +2, -2 1126840000 Lid for DIN-rail-mounted devices 8000007627 NEW Cable seals various E Blank seal 4323240000 Locking element 1816130000 Snap on DIN rail, 54 mm 1170690000 DC labelling 1366860000 – 2013 E.9 IP 65 switched-mode power supply / Electrical cabinet socket outlet Housings E Housings GH 10P PT6 BG GH 10P 4XVG PT6 With 4 additional M20 cable glands The housings can be assembled during the mechanical work. The PT6 contact unit is simply snapped on with or without a power bus. The TS 35 PT6 DIN-rail module can be used optionally. Technical data Insulating material Material colour UL 94 flammability class Halogen free / Silicone free Degree of protection when closed Temperature range / storage Lid attachment Housing attachment PC GF 10 black 5VA Yes / Yes IP 65 -40 °C…55 °C / -40 °C...85 °C Screws Mounting tabs PC GF 10 black 5VA Yes / Yes IP 65 -40 °C…55 °C / -40 °C...85 °C Screws Mounting tabs Note Clamping range of the cable glands 6–12 mm Ordering data Type GH 10P PT6 Note Qty. 10 Order No. 1121980000 Housing lid BG GHDE 10P PT6 1122200000 Housing lid BG GHDE 10P HO PT6 1121950000 Type BG GH 10P 4XVG PT6 Qty. 10 Order No. 1121990000 Qty. 10 Order No. 1170690000 Housing lid BG GHDE 10P PT6 1122200000 Housing lid BG GHDE 10P HO PT6 1121950000 Accessories Type TS 35 PT6 Note E.10 Qty. 10 Order No. 1170690000 Usable width 54 mm Can be installed in 1070140000, 1121980000, 1121990000 Type TS 35 PT6 Usable width 54 mm Can be installed in 1070140000, 1121980000, 1121990000 1366860000 – 2013 Lid BG GHDE 10P PT6 IP 65 switched-mode power supply / Electrical cabinet socket outlet Housings BG GHDE 10P HO PT6 FieldPower lids are very sturdy and meet the highest UL flammability rating 5VA. The large number of varieties means you can install the devices on DIN mounting rails or mounting plates. ® 67 164 192 181 181 192 E Technical data Insulating material Material colour UL 94 flammability class Halogen free / Silicone free Degree of protection when closed Temperature range / storage Lid attachment PC GF 10 black 5VA Yes / Yes IP 65 -40 °C…55 °C / -40 °C...85 °C Screws PC GF 10 black 5VA Yes / Yes IP 65 -40 °C…55 °C / -40 °C...85 °C Screws Note Housing height: 67 mm Housing height: 164 mm Refer to the project planning documentation for the detailed dimensions Ordering data Note Type BG GHDE 10P PT6 Qty. 10 Order No. 1122200000 Housing base section GH 10P PT6 1121980000 Housing base section BG GH 10P 4XVG PT6 1121990000 Type BG GHDE 10P HO PT6 Qty. 10 Order No. 1121950000 Housing base section GH 10P PT6 1121980000 Housing base section BG GH 10P 4XVG PT6 1121990000 Accessories Note 1366860000 – 2013 E.11 IP 65 switched-mode power supply / Electrical cabinet socket outlet Housings Seals for FieldPower® Box Seal for round cable Blanking seal IP 65 enclosure seals for the FieldPower Box modules: made from silicone-free, halogen-free material. The seals are slit in the middle to allow for simple installation with uncut power cables. ® ø E Technical data General data Material UL 94 flammability class Colour Thickness Line type Free from halogens Silicone-free Ingress protection class EPDM HB black 18 mm round Yes Yes IP 65 EPDM HB black 18 mm Yes Yes IP 65 Note Ordering data Clamping range Ø 7.5 - 9 mm 9 - 11 mm 11 - 13 mm 13 - 15 mm 15 - 17 mm Type RKDG D9 PT6 RKDG D11 PT6 RKDG D13 PT6 RKDG D15 PT6 RKDG D17 PT6 Qty. 10 10 10 10 10 Order No. 4329610000 4323210000 4323230000 4323220000 4324010000 Type DG D0 PT6 Qty. 10 Order No. 4323240000 Note Accessories Note E.12 1366860000 – 2013 IP 65 switched-mode power supply / Electrical cabinet socket outlet The method of connection FieldPower® – The method of connection 1 2 3 0.6 Nm 0 13 m m E 4 5 6 90° Klick Klick IDC 2.5...6 mm2 7 8 2.0 Nm ? A practical tip FieldPower® is the best solution when the cable is too short. The cable need only be stripped and not cut through. No mix-ups or wrong connections are possible. This is also a perfect solution for retrofit installations. An installation video can be seen at www.weidmueller.com/de/FieldPower_Video 1366860000 – 2013 E.13 IP 65 switched-mode power supply / Electrical cabinet socket outlet Contact modules and plug connectors PowerTerminal for AC/DC applications A contact element for power distribution using uncut wires with cross-sections from 1.5 to 6 mm². Feed-in / T-branch tap via PUSH IN connection (0.5 to 10 mm²) and/or plug-in connection (0.5 to 4 mm²). Clear and precise wire assignments: with coding on the PE connection. PT6 PT6 DC for AC applications for DC applications • Power supply • Power distribution • Power branching { 61.5 E DC labelling AC labelling 53.9 139.5 Technical data Rated data according to IEC 60947-7-1 Rated cross-section Rated voltage/Rated current Rated impulse voltage General data Insulation material/material colour UL 94 flammability class Free from halogens/Silicone-free Protection degree Assembly temperature range, min.-max. Operating temperature, min.-max. Can be coded IDC connection clamping capacity - power cable Solid, min.-max. Stranded, min.-max. Flexible, min.-max. Flexible, min.-max. Blade size PUSH IN connection clamping capacity - distribution Solid, min.-max. Stranded, min.-max. Flexible, min.-max. Flexible, wire end ferrule 8 mm, DIN 46228/1, min-max. Flexible, wire end ferrule 8 mm, DIN 46228/4, min-max. Flexible, wire end ferrule 12 mm, DIN 46228/1, min-max. Flexible, wire end ferrule 12 mm, DIN 46228/4, min-max. Flexible, min.-max. Stripping length/Blade size Rated data according to UL Standard Rated voltage/Rated current AWG conductor (field wiring) min./max. Note Note Ordering data 6 mm² 800 V / 41 A 8 kV 6 mm² 800 V / 41 A 8 kV PA/grey V0 Yes/Yes IP 20 10 °C...40 °C -40 °C...55 °C Yes/Coded on PE PA/grey V0 Yes/Yes IP 20 10 °C...40 °C -40 °C...55 °C Yes/Coded on PE 1.5 mm²…6 mm² 2.5 mm²…6 mm² 2.5 mm²…6 mm² 2.5 mm²…6 mm² 0.6 x 3.5 mm 1.5 mm²…6 mm² 2.5 mm²…6 mm² 2.5 mm²…6 mm² 2.5 mm²…6 mm² 0.6 x 3.5 mm 0.5 mm²…6 mm² 0.5 mm²…6 mm² 0.5 mm²…10 mm² 0.5 mm²…6 mm² 0.5 mm²…6 mm² 0.5 mm²…6 mm² 0.5 mm²…6 mm² 0.5 mm²…6 mm² 14 mm / 0.6 x 3.5 mm UL 1059 600 V/30 A 14 /10 For use with UL-listed TC-ER cables 0.5 mm²…6 mm² 0.5 mm²…6 mm² 0.5 mm²…10 mm² 0.5 mm²…6 mm² 0.5 mm²…6 mm² 0.5 mm²…6 mm² 0.5 mm²…6 mm² 0.5 mm²…6 mm² 14 mm / 0.6 x 3.5 mm UL approval is pending. UL 1059 600 V/30 A 14 /10 For use with UL-listed TC-ER cables Tip: Pipe Ölflex Classic 100, 110, 100 H or comparable Tip: Pipe Ölflex Classic 100, 110, 100 H or comparable Type PT6 Qty. 1 Order No. 1957620000 Type PT6 DC Qty. 1 Order No. 1126840000 Note Accessories Note E.14 Plug-in connector PTS 4 1952120000 Plug-in connector PTDS 4 1952130000 Plug-in connector PTS 4 DC 1131730000 Plug-in connector PTDS 4 DC 1009990000 1366860000 – 2013 PowerTerminal for AC/DC applications A contact element for power distribution using uncut wires with cross-sections from 1.5 to 6 mm². Feed-in / T-branch tap via PUSH IN connection (0.5 to 10 mm²) and/or plug-in connection (0.5 to 4 mm²). Coloured markings for unambiguous wire assignments according to DIN VDE 0293-308. IP 65 switched-mode power supply / Electrical cabinet socket outlet Contact modules and plug connectors PT6 230/… For mixed applications • Power supply • Power distribution • Power branching Black Snap-on mounting rail Blue Yellow/Green 53.9 61.5 Brown 139.5 Colour coding DIN VDE 0293-308 Grey E Technical data Rated data according to IEC 60947-7-1 Rated cross-section Rated voltage/Rated current Rated impulse voltage General data Insulation material/material colour UL 94 flammability class free from halogens/Silicone-free Protection degree Assembly temperature range, min.-max. Operating temperature, min.-max. Can be coded IDC connection clamping capacity - power cable Solid, min.-max. Stranded, min.-max. Flexible, min.-max. Flexible, min.-max. Blade size PUSH IN connection clamping capacity - distribution Solid, min.-max. Stranded, min.-max. Flexible, min.-max. Flexible, wire end ferrule 8 mm, DIN 46228/1, min-max. Flexible, wire end ferrule 8 mm, DIN 46228/4, min-max. Flexible, wire end ferrule 12 mm, DIN 46228/1, min-max. Flexible, wire end ferrule 12 mm, DIN 46228/4, min-max. Flexible, min.-max. Stripping length/Blade size Rated data according to UL Standard Rated voltage/Rated current AWG conductor (field wiring) min./max. Note Note Ordering data 6 mm² 800 V / 41 A 8 kV The mounting rail TS 35 PT6 provides 54 mm of installation width and can be used at two heights. This creates space for wires under the mounting rail. PA/grey V0 Yes/Yes IP 20 10 °C...40 °C -40 °C...55 °C Yes 54 mm 1.5 mm²…6 mm² 2.5 mm²…6 mm² 2.5 mm²…6 mm² 2.5 mm²…6 mm² 0.6 x 3.5 mm 0.5 mm²…6 mm² 0.5 mm²…6 mm² 0.5 mm²…10 mm² 0.5 mm²…6 mm² 0.5 mm²…6 mm² 0.5 mm²…6 mm² 0.5 mm²…6 mm² 0.5 mm²…6 mm² 14 mm / 0.6 x 3.5 mm UL approval is pending. UL 1059 600 V/30 A 14 /10 For use with UL-listed TC-ER cables ✓ ✓ M≤ 0.4 kg M≤ 0.4 kg CLICK Tip: Pipe Ölflex Classic 100, 110, 100 H or comparable CLICK Type PT6 230/BUS Qty. 1 Order No. 1269960000 1121980000 1121990000 Note Accessories Note 1366860000 – 2013 Plug-in connector PTS 4 MBP 1010190000 E.15 IP 65 switched-mode power supply / Electrical cabinet socket outlet Contact modules and plug connectors Plug-in connectors for AC applications PTS 4 PTDS 4 2 connections per pole Plug-in connectors for use by the pluggable output of the contact elements. Individual wires can be connected with PUSH IN method: for cross-sections from 0.5 to 4 mm². Can be coded and locked, with printing for trouble-free wiring. Clear wire mapping with coding for PE connections. { E 27.3 27.3 22 55.45 36.15 22 36.15 55.45 { Technical data Rated data according to IEC 60947-7-1 Rated cross-section Rated voltage/Rated current Rated impulse voltage General data Type of mounting Insulation material/material colour UL 94 flammability class Continuous operating temp., min.-max. Outgoing direction of conductor Test point Can be coded Conductor connection system No. of poles Number of connections / pole Clamping capacity, PUSH IN connection Clamping range, min.-max. Solid, min.-max. Stranded, min.-max. Flexible, min.-max. Flexible, wire end ferrule 8 mm, DIN 46228/1, min.-max. Flexible, wire end ferrule 8 mm, DIN 46228/4, min.-max. Flexible, wire end ferrule 12 mm, DIN 46228/1, min.-max. Flexible, wire end ferrule 12 mm, DIN 46228/4, min.-max. Flexible, min.-max. Stripping length/Blade size Rated data according to UL Standard Rated voltage/Rated current AWG conductor (field wiring) min./max. 4 mm² 690 V / 32 A 8 kV 4 mm² 690 V / 32 A 8 kV Plugged PA GF/ black V0 -50 °C...120 °C 90° 2 mm Yes/Coded on PE PUSH IN 5 1 Plugged PA GF/ black V0 -50 °C...120 °C 90° 2 mm Yes/Coded on PE PUSH IN 5 2 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 12 mm / 3.0 x 0.5 mm 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 12 mm / 3.0 x 0.5 mm UL 1059 600 V/20 A 16 /12 UL 1059 600 V/20 A 16 /12 Note Ordering data Type PTS 4 Qty. 10 Order No. 1952120000 Type PTDS 4 Qty. 10 Order No. 1952130000 Note Accessories Note E.16 ZVR ZP2.5 locking element 1816130000 ZVR ZP2.5 locking element 1816130000 1366860000 – 2013 PTS 4 DC PTDS 4 DC 2 connections per pole Plug-in connectors for use with the pluggable outlet of the PT6 contact elements. Single-wire PUSH IN connection for wire cross-sections ranging from 0.5 to 4 mm². Can be coded and latched down. Clear wire mapping with DC labelling and coding for PE connections. 27.3 27.3 55.45 36.15 22 36.15 55.45 22 Plug-in connectors for DC applications IP 65 switched-mode power supply / Electrical cabinet socket outlet Contact modules and plug connectors E Technical data Rated data according to IEC 60947-7-1 Rated cross-section Rated voltage/Rated current Rated impulse voltage General data Type of mounting Insulation material/material colour UL 94 flammability class Continuous operating temp., min.-max. Outgoing direction of conductor Test point Can be coded Conductor connection system No. of poles Number of connections / pole Clamping capacity, PUSH IN connection Clamping range, min.-max. Solid, min.-max. Stranded, min.-max. Flexible, min.-max. Flexible, wire end ferrule 8 mm, DIN 46228/1, min.-max. Flexible, wire end ferrule 8 mm, DIN 46228/4, min.-max. Flexible, wire end ferrule 12 mm, DIN 46228/1, min.-max. Flexible, wire end ferrule 12 mm, DIN 46228/4, min.-max. Fexible, min.-max. Stripping length/Blade size Rated data according to UL Standard Rated voltage/Rated current AWG conductor (field wiring) min./max. Note Ordering data 4 mm² 690 V / 32 A 8 kV 4 mm² 690 V / 32 A 8 kV Plugged PA GF/ black V0 -50 °C...120 °C 90° 2 mm Yes/Coded on PE PUSH IN 5 1 Plugged PA GF/ black V0 -50 °C...120 °C 90° 2 mm Yes/Coded on PE PUSH IN 5 2 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 12 mm / 3.0 x 0.5 mm 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 12 mm / 3.0 x 0.5 mm UL 1059 600 V/20 A 16 /12 UL 1059 600 V/20 A 16 /12 UL approval is pending. UL approval is pending. Type PTS 4 DC Qty. 10 Order No. 1131730000 Type PTDS 4 DC Qty. 10 Order No. 1009990000 Note Accessories Note 1366860000 – 2013 ZVR ZP2.5 locking element 1816130000 ZVR ZP2.5 locking element 1816130000 E.17 IP 65 switched-mode power supply / Electrical cabinet socket outlet Contact modules and plug connectors Plug-in connectors for mixed applications PTS 4 blank Plug-in connector for use by the pluggable output of the contact elements. Individual wires can be connected with PUSH IN method: for cross-sections from 0.5 to 4 mm². Can be coded and locked. E 27.3 22 36.15 55.45 Technical data Rated data according to IEC 60947-7-1 Rated cross-section Rated voltage/Rated current Rated impulse voltage General data Type of mounting Insulation material/material colour UL 94 flammability class Continuous operating temp., min.-max. Outgoing direction of conductor Test point Can be coded Conductor connection system No. of poles Number of connections / pole Clamping capacity, PUSH IN connection Clamping range, min.-max. Solid, min.-max. Sstranded, min.-max. Flexible, min.-max. Flexible, wire end ferrule 8 mm, DIN 46228/1, min.-max. Flexible, wire end ferrule 8 mm, DIN 46228/4, min.-max. Flexible, wire end ferrule 12 mm, DIN 46228/1, min.-max. Fflexible, wire end ferrule 12 mm, DIN 46228/4, min.-max. Flexible, min.-max. Stripping length/Blade size Rated data according to UL Standard Rated voltage/Rated current AWG conductor (field wiring) min./max. 4 mm² 690 V / 32 A 8 kV Plugged PA GF/ black V0 -50 °C...120 °C 90° 2 mm YES / Not coded PUSH IN 5 1 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 12 mm / 3.0 x 0.5 mm UL 1059 600 V/20 A 16 /12 Note Ordering data Type PTS 4 MPB Qty. 10 Order No. 1010910000 Note Accessories Note E.18 ZVR ZP2.5 locking element 1816130000 1366860000 – 2013 Fuse plug-in connector Max. power loss for G fuse terminals in accordance with IEC 60947-7-3: •Overload protection: 1.6 W (at 1.5 x IN) •Short-circuit protection: 4 W (at 1.5 x IN) Max. power loss per fuse at 23 °C Tu. IP 65 switched-mode power supply / Electrical cabinet socket outlet Contact modules and plug connectors PTSI 4 / PTSI 4/ LD { Do not exceed the max. power loss when selecting fuse cartridges. When a fuse is defective, the subsequent circuit is not voltage free. for AC applications for DC applications A practical tip: Space for spare fuses Rated data according to IEC 60947-7-3 Rated cross-section Rated voltage/Rated current (as disconnect terminal) Rated impulse voltage General data Cartridge fuse Outage display Type of mounting Insulation material/material colour UL 94 flammability class Continuous operating temp., min.-max. Outgoing direction of conductor Test point Can be coded Conductor connection system No. of poles Number of connections / pole Clamping capacity, PUSH IN connection Clamping range, min.-max. Solid, min.-max. Stranded, min.-max. Flexible, min.-max. Flexible, wire end ferrule 8 mm, DIN 46228/1, min.-max. Flexible, wire end ferrule 8 mm, DIN 46228/4, min.-max. Flexible, wire end ferrule 12 mm, DIN 46228/1, min.-max. Flexible, wire end ferrule 12 mm, DIN 46228/4, min.-max. Fexible, min.-max. Stripping length/Blade size Rated data according to UL Standard Rated voltage/Rated current AWG conductor (field wiring) min./max. Note Ordering data PTSI 4...AC E PTSI 4...DC 4 mm² 500 V / 12 A 6 kV 4 mm² 36 V / 12 A 6 kV 6.3 x 32 mm (1/4 x 1 1/4") LED red Plugged PA GF/ black V0 -50 °C...120 °C 90° 2 mm Yes/Coded on PE PUSH IN 5 1 6.3 x 32 mm (1/4 x 1 1/4") LED red Plugged PA GF/ black V0 -50 °C...120 °C 90° 2 mm Yes/Coded on PE PUSH IN 5 1 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 12 mm / 3.0 x 0.5 mm 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 12 mm / 3.0 x 0.5 mm UL 1059 600 V/20 A 16 /12 – – – Note IP 20 IP 65 Only short-circuit Overload and protection short-circuit protection TA max. Nominal values TA max. Nominal values 46 °C 4.0 W / 10 A 28 °C 2.5 W / 2.5 A 23 °C 4.0 W / 10 A 39 °C 1.6 W / 1.0 A Fuses and power loss: Examples Current 1.0 A 1.6 A 2.0 A 4 A 6.3 A 8 A 10 A 12.5 A SIBA, 189140 1.0 x IN 0.35 W 0.32 W 0.36 W 0.56 W 0.69 W 0.88 W 1 W 500 V, 440 V, 250 V 1.5 x IN 0.9 W 1.1 W 1.2 W 1.5 W 2.2 W 2.6 W 3.0 W T SIBA, 1.0 x IN – – – – 1.2 W 1.5 W 1.8 W 7006584 400 V 1.25 x IN – – – – 2.5 W 3.2 W 3.7 W gRL No responsibility is taken for the accuracy of this information. Further details can be obtained from the fuse manufacturers. 1.25 W 3.5 W 1.9 W 3.9 W Derating curve for IP 65 use: Safety fuse not included in delivery. Rated voltage and rated current with fuse are determined by the G-fuse cartridge in use. Type PTSI 4/LD 400V AC PTSI 4/LD 36V AC/DC Protection degree Qty. 1 1 Order No. 1961770000 1252210000 Power loss P [W] bei I = 1,5 x IN Technical data 4,5 4 3,5 3 2,5 2 1,5 1 0,5 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Ambient temperature T [°C] Only short-circuit protection Overload and short-circuit protection Accessories Note 1366860000 – 2013 ZVR ZP2.5 locking element 1816130000 E.19 IP 65 switched-mode power supply / Electrical cabinet socket outlet Help with project planning Help with project planning FieldPower® Control CAD models can be found in our online catalogue at http://catalog.weidmueller.com BG GHDE HO PT6 BG GHDE 10P HO PT6 PTS 4... PT6... GH PT6 GH 10P PT6 E BG GHDE HO PT6 BG GHDE 10P HO PT6 PTS 4... PT6... GH PT6 GH 10P PT6 23 75 72.2 78.5 GHDE 10P HO ON/OFF PTS4 BG GHDE HO SA UL PT6 PT6... GH PT6 GH 10P PT6 34.7 44.5 34.7 56.5 66 64 BG GHDE HO PT6 BG GHDE 10P HO PT6 TS 35 PT6 GH PT6 GH 10P PT6 38.4 20 4.35 7.6 77 73 34.7 56.5 E.20 115.4 Ø 3.4 Ø 7.8 164 87 84 66 54 65 6 65.5 1366860000 – 2013 IP 65 switched-mode power supply / Electrical cabinet socket outlet Help with project planning BG GHDE 10P HO PT6 84 87 160.5 56 E 46 1.5 ± 0.3 Nm 135 10 46 56 Ø8 Ø 3.4 6 5.7 ± 0.1 2 Ejot Delta PT WN5412 H 40x... 159 Screw-in depth TS 35 PT6 GH 10P PT6 33.5 54.5 1 0 45 ±0.5 45 55 6.8 ≤ 44 40 8.5 46.5 68 68 58 68 8.5 68 583 58 mm Pos. 2 1x 40 50 >2 click ≤ 82 0 ≤ 67 0 45 6.9 55 43 45 0 0 54.5 43 1 1 1 0 55 43 BG GHDE 10P REG 54.5 1 1 35 8.5 ≤ 55 46.5 ≤ 55 152 1,5 Nm 1366860000 – 2013 Pos. 3 E.21 Help with project planning FieldPower® DC-Network U/V 23.75 V 23.25 V Input 400 V ∼ L1, L2, L3, h 0.5…4 mm2 0.4…0.5 Nm SD 0.6 x 3.5 x 100 ≤ 300 ms E 1 0 2.5 5 5.3 7.5 10 #2 #6 LS+ LS- LOAD SHARE 0.2…1.5 mm2 0.2…0.25 Nm SD 0.4 x 2.5 x 75 Fault Relay ≤ 1 A / 24 V COM, NO Output 24 V DC 5 A +, +, -, - 2 #1 LSLSLS+ LS+ 24 V 24.25 23 Loadshare Bus LSLSLS+ LS+ Actuating variable and load limit LSLSLS+ LS+ IP 65 switched-mode power supply / Electrical cabinet socket outlet Help with project planning LOAD SHARE bus connection: twisted pair cable (for example, Ölflex) 12.5 I/A Installed position ≥ 15 mm a) b) ≥ 15 mm c) d) Ø 6…12 mm 59.4 47.7 Power in W Derating curve 150 P 140 max 130 120 Prated 110 100 90 80 70 60 50 40 30 20 10 0 0 a) c) d) b) 10 20 30 40 50 60 70 80 Tu in °C E.22 1366860000 – 2013 1366860000 – 2013 192 177 192 FieldPower® Box 10P IP 65 switched-mode power supply / Electrical cabinet socket outlet Drilling template E 165 181 E.23 IP 65 switched-mode power supply / Electrical cabinet socket outlet Electrical cabinet socket outlet Electrical cabinet socket outlet Schuko TS35 • S imple installation in electrical cabinet • T S35 module can be mounted on rail • V DE mark of conformity • T wo-pole with earthing contact Technical data E Rated voltage Rated voltage, max. Rated current Clamping range, nom. Tightening torque Ambient temperature (operational) Surge voltage category Pollution severity Protection degree Approvals Dimensions Clamping range (nominal / min. / max.) Height x width x depth Note 230 V 250 V 16 A 1 mm² - 1,5 mm² 1.3 Nm -20...+40 °C II 2 IP 20 CE; VDE mm² 1.5 / 1 / 1.5 45 / 76 / mm Ordering data Type Schuko TS35 Qty. 10 Order No. 8734580000 Note Accessories Note E.24 1366860000 – 2013 Weidmüller Solutions & Service Contents Weidmüller Solutions & Service Weidmüller Solutions & Service Customer specific solutions: best advice, best solutions V.2 Digital support: RailDesigner , Product Assistant for Distribution Boxes, Online product catalogue, M-Print® PRO label designer V.8 ® V 1366860000 – 2013 V.1 Weidmüller Solutions & Service Customer specific solutions Application specific solutions – Your requirements are our motivation Each industry has its own requirements calling for more and more individual solutions aside from standard products. Your new product might have to contend with severe conditions. In addition, many applications are subjected to high mechanical strains – through vibration or directly applied forces. Extreme temperature conditions or an application in hazardous areas are further factors you will need to take into account, and your product must comply with the appropriate standards for these conditions. We can offer you highly competent expertise to support you in the selection of ideal products, whatever your application. Feel free to contact us! Individual product development Working closely with you, we can develop individual and future-proof products using the latest technologies and which are specifically tailored to your application. From custom product development, customer-specific assembly or application-specific products that are ready for use - we can help you to optimise your working processes and ensure your company‘s sustained efficiency, today, as well as for the future. Application-specific products Our cross-industrial solutions set standards: Set up for your application, instantly ready for use and available from stock. Customer-specific assembly Our highly-skilled production expertise and broad product portfolio means that we can deliver superior solutions to meet and exceed your specification requirements. V V.2 1366860000 – 2013 Weidmüller Solutions & Service Customer specific solutions Individual product development for your success We have a passion for simple, innovative solutions Working with you, we can develop innovative and future-oriented products tailored to your application. Our philosophy is „one customer - one product“. It is not the product that is the starting point, but you, your technical specifications and your requirements. A connecting partnership The development of individual products means making the most of the experience and competencies available in the partnership. Our project management provides a professional and quality approach - from concept and design through to development, implementation and production. Our extensive knowledge of electrical connectivity, enclosure and sealing technology, as well as signal conditioning, are all at your disposal. Benefit from a reliable partner: •Increase the efficiency of your development and production processes Outsourcing the development and production of your components will shorten your time-to-market. In addition, you have more time to concentrate on your core competencies. •Take advantage of our applications and production expeience and expertise You can draw on the accumulated knowledge of our applications engineers and our specialists in the fields of connection technology, enclosure and surface technology, as well as metal and plastic processing, which is second to none. •Feel safe with the professional approach of our project management Through innovation workshops, feasability studies and profitability analyses we define a requirement profile forming the basis for the further development process. In this way, you can be sure of the best possible products for your needs. V 1366860000 – 2013 V.3 Weidmüller Solutions & Service Customer specific solutions Application specific products – solutions for industries and markets Industries and applications often have similar or even identical requirements for products or product assemblies. Application specific products that are based on earlier realised solutions are now directly available from stock. Your advantage: You quickly get a suitable and cost-efficient solution. Cross industrial solutions as standard It is our aim to develop solutions that offer the additional advantage of a truly flexible design. Although this may mean an application-specific product may have an additional input or terminal you don‘t need, it can still be much cheaper than having a custom-made solution. Therefore, you not only save time, but money! Reap multiple benefits: •High availability Application specific products are available from stock without delay. So you can rely on the delivery of your products when you need them. •Advice from application engineers Using the expertise of our applications engineers means that you can develop solutions that are not only right, but which deliver added value to your applications. •Supportive software Project planning and evaluation is made easy with our software solutions such as NetCalc®, RailDesigner® or Softclinic. •Worldwide application centres We stay in constant dialogue with our worldwide application centres, ensuring that our own application knowledge is shared, kept up to date and at your disposal anywhere you need us. V V.4 1366860000 – 2013 Customer specific assembly, tailored configuration You may be looking to bring costs down and increase your efficiency. It may be that you would like more time to focus on your core competencies. You could be looking for a partner who will set up intelligent solutions for you, and who you can trust to deliver your specific requirements. Here at Weidmüller, we have a wealth of expertise, capability, and capacity to deliver custom solutions that are flexible, economically advantageous and on time. We offer to work closely with you, providing support and advice, and in putting together the job specification. Furthermore, our broad product portfolio means that we can jointly work together on the selection of the best components to make up your custom solution. Take advantage of: •Simple ordering and stockholding information One solution – one item number! It will no longer be necessary to order single components. Article variety and stockholding will be reduced. •Professional assembly All individual components will be pre-assembled, reducing your own assembly time and costs. 1366860000 – 2013 Weidmüller Solutions & Service Customer specific solutions T Highest levels of professional production You have complete access to our highly-skilled project management team and our production expertise, for example, in the ATEX area. We can offer you a comprehensive portfolio of customer-specific assemblies, from simple assembly to the modification of existing electronics products. Our services include: •Adaptation and assembly of enclosures for all IP protection classes • ATEX solutions for hazardous areas • Assembly of heavy duty connectors • Assembly of terminal strips • Customer specific electronics solutions • Cable assembly •Less costs for documentation Our RailDesigner® software will facilitate the generation of parts lists or drawings. •Modern processing of enclosures Our CNC processing centres can adapt the enclosures to suit your tailored solution. V V.5 Weidmüller Solutions & Service Customer specific solutions Customer specific assembly — consultation, product, development and production – all from a single source Our application and manufacturing expertise influences decisions on all areas of modern connection technology. They therefore play an integral part of every solution. Enclosures Perfect protection and safety • Enclosures for all IP protection classes • ATEX enclosures for hazardous areas • Placement of inspection glasses, drill holes and threads •Elaborate machining operations like the milling of contours •Class C5 welding, according to DIN 6700, for stainless steel and sheet steel enclosures • Surface coating as and when required • Individual device and system markers T Heavy duty connectors Perfect connection with system • Placement of drill holes and cable glands • Equipped with plug-and-play components • Wiring of sub-assemblies • Cable assembly • All housings are available with individual laser marking Terminal strips Configuration made to measure • Machining of mounting rails • Snapping components onto terminal rails • Placement of cross connections • Mounting of standard conductors • Marking of terminals, devices, conductors and cables V V.6 1366860000 – 2013 Weidmüller Solutions & Service Customer specific solutions Electronics Individual solution from the beginning •Modular terminal blocks, component plugs, snap on bases, enclosures for electronics: integration of relevant electronic components •Snap-on base: Component carrier design or simple wiring of the modules • Interface units •Modification of existing electronic products: modification of the circuitry or specific calibration •Combination of components: relays or optocouplers in combination with other components Cable assembly Our special service •Pre-cutting of cables and conductors •Installation of - Heavy duty connectors - PCB connectors or DIN connectors •Conditioning of wire ends •Mounting of wire end ferrules and cable lugs •Connection of conductors to terminal rails V 1366860000 – 2013 V.7 Weidmüller Solutions & Service Digital support RailDesigner® A faster way to configure and order terminal strips These days, time and cost efficiency are of the essence when it comes to working in planning and production. RailDesigner®, our free configuration and purchasing software, uses its virtual assembly of mounting rails (assembled or unassembled) to help you with the design of your own, completely personal solution. RailDesigner® brings you substantial benefits: Less time required It speeds up the process of acquiring quotations and placing orders because, for example, all processes can be initiated directly from the software. You configure your projects and the rest virtually takes care of itself! User friendly operation Any potential errors are prevented by automatic installation tips and clear project processing and management. So that you can plan your project realistically, RailDesigner® offers both 2D and 3D displays. V Wide selection from the current product portfolio You can easily download software updates for RailDesigner® from the internet. This means that you will always have access to the latest version of our product database. Project planning that is compatible with your software Plan and design your projects easily using your usual CAE software. With the integrated interface, transferring data from your CAE system has never been so simple. You can export component lists and terminal strip designs in various formats. Marking data is automatically transferred to the M-Print® Pro labelling software. Simple purchasing of terminal strips Once you have completed the planning stages of your projects in RailDesigner®, you can choose to send all of your data to us by email. Then we take over the assembly and deliver the required configuration to you, along with anything else that you still require for your project. Download the software for free and discover the advantages to using RailDesigner® at www.raildesigner.de V.8 1366860000 – 2013 Weidmüller Solutions & Service Digital support Product assistant for distribution boxes and assemblies – The perfect solution, in the shortest time You can easily and quickly select, combine and purchase the required components, all with the help of the Weidmüller product assistant for distribution boxes and assemblies. This means that you can rapidly obtain your individual enclosure solutions which may include the following components: Empty enclosures without holes Empty enclosures in various sizes of the Klippon® K and Klippon® POK series (aluminium and plastic) with matching mounting rails. Empty enclosures with pre-threaded holes Empty enclosures in different sizes from the Klippon® K and Klippon® POK series (aluminium and plastic), that are already equipped with metric threaded holes. Mounting rails Exactly tailored mounting rails for the enclosure sizes on offer. Terminal strips Mounting rails, which also perfectly match the offered enclosure sizes and are pre-fitted with terminals, optionally with screw or tension clamp connection. Distribution boxes with Ex-protection Enclosures that are already assembled with a terminal strip and already equipped with metric threaded holes. 1366860000 – 2013 Numerous possible combinations Enclosures with Ex-protection are supplied exclusively with terminal strips that are already fitted. The product assistant offers you various approaches for industry variants so that you can create the right enclosure variant. You can start off with any of the listed components and then add further components to the combination. This means that, for example, you can select the required terminal strip and the product assistant will then offer the matching enclosure variants. Or, you can start with the enclosure, and matching terminal strips or mounting rails will then be chosen. The selected products can then be directly included in the query list. Provision of all relevant data During the selection, you can choose filters for the terminal strips, such as length, connection technology or dimensional cross-section and, for the enclosure, you can choose material, size, holes etc. If a product is then selected and combined, the user can view all of the relevant data, including drawings and pictures. This means that you can extensively plan how the enclosure will be integrated into the customer‘s application. The product assistant is available at http://galaxy.weidmueller.com V V.9 Weidmüller Solutions & Service Digital support Online product catalogue If you have questions about the specifications and details of our products, even outside normal business hours, then our online catalogue at http://catalog.weidmueller.com is opened 24 hours a day, 365 days a year and is the perfect source for information. Besides product features and part numbers, it contains extensive additional information on all product groups. For further information, offers and your personal contact, simply consult the Weidmüller website at www.weidmueller.com With one click selection for the product data sheet of your choice. M-Print® PRO label designer Our comprehensive range of Weidmüller services includes the M-Print® PRO software. This is a professional standard, Windows®-based program for printing and ordering labels and markers that is coordinated with our current printing systems and marking materials. V V.10 M-Print® PRO enables you to design your labelling materials professionally and quickly. Texts, borders, lines, graphics, barcodes, serial numbers and photographs are all possible. The interface to RailDesigner® or your CAE system enables the transfer of all your configured data. 1366860000 – 2013 Glossary/Technical appendix Contents Glossary/Technical appendix Glossary/Technical appendix Power Supplies – Overview W.2 Standards and approvals W.4 Glossary W.6 W 1366860000 – 2013 W.1 Glossary/Technical appendix Power Supplies – Overview Power Supplies – Overview Power supplies are important links in the energy supply chain of automation systems. Unregulated power supplies or regulated switched-mode power supplies are at the heart of every electrical cabinet. 24 V DC has emerged as the standard control voltage for the supply of electrical subassemblies and systems. But other control voltages are also required. The correct power supply is a critical factor for the reliable operation of the supplied components. Thus it must be chosen with particular attention. Power supplies from Weidmüller, whether regulated or unregulated, have proven themselves reliable over many years in the supply of electrical sub-assemblies and systems. They perform reliably and safely – even under harsh industrial conditions – in all sectors of machine construction, industrial automation, and the power and process industries. Weidmüller offers custom-fit solutions for practically all of your requirements: • Unregulated transformer power supplies • Primary switch-mode power supplies • DC/DC converters • Diode modules • UPS control modules • Electronic fusing How they work Unregulated power supply units consist of a mains power transformer that transforms the input voltage into a different AC voltage. The units then make use of a rectifier and a filter circuit to smooth out the DC output voltage. Mains (AC) Output Unregulated transformer power supply Regulated power supply units in the range up to 1,000 W are usually designed as primary switched-mode power units. The mains AC voltage is then rectified and transformed in high frequency to the secondary side using switching transistors and power transformers. This is followed by the rectifier and filter circuit in order to generate the DC output voltage. A control circuit compares the current and voltage on the output side to the specified target values and then generates a control signal for the switching transistors. This permits compensation for load changes and mains voltage fluctuations. As a result, the output voltage remains stable. These power supply units are increasingly being operated with DC input voltages (for example, Weidmüller‘s PRO-M line of switched-mode power supplies). Controller Mains (AC/DC) Output Switched-mode power supply W W.2 1366860000 – 2013 Glossary/Technical appendix Power Supplies – Overview A DC/DC converter is a variation of the classic switched mode power supply. The switching strategy is similar but there is no input rectifier. Starting with a specified DC input voltage, DC/DC converters generate a different DC voltage at a similar or different level. They are used to adapt different voltage levels and also for isolating potentials. Controller Mains (DC) Output DC/DC converter In use around the globe Weidmüller‘s power supply units have been designed for use around the world. They can be used in practically all applications throughout the world because of their CE label and many other national and international approvals. Their wide input voltage ranges and compatibility with various mains power connections increases their global appeal. Temperature range During operation, power supply units generate power losses. In Weidmüller‘s switched-mode power supplies, the resulting heat is dispersed using natural air currents only. The design, which does not make use of a ventilation fan, is an example of our uncompromised durability standard. Weidmüller‘s power supply units, depending on the model, can be used in temperatures ranging from -25 °C to +70 °C. Compact and efficient design Weidmüller‘s switched-mode power supplies are extra small because they take advantage of the above-average degree of efficiency offered by the latest technologies. The power supplies from Weidmüller – whether they are book-shaped with minimised base surface, or variants with reduced height for use in distributor boxes – always provide the proper costsaving solution. 1366860000 – 2013 W W.3 Glossary/Technical appendix Standards and approvals W W.4 Standards and approvals Standard/Approval Description DIN EN 50178 (VDE 0160) Electronic equipment for use in power installations DIN EN 60950-1 (VDE 0805-1) IT Equipment – Safety – Part 1: General requirements DIN EN 61558-1 (VDE 0570-1) Safety of transformers, power supply units, throttles and similar devices Part 1: General requirements and tests DIN EN 61558-2-17 (VDE 0570 Part 2-17) Safety of transformers, power supply units and similar devices Part 2-17: Special requirements for switch-mode power supply transformers DIN EN 60204-1 (VDE 0113-1) Safety of machinery – Electrical equipment of machinery – Part 1: General requirements DIN VDE 0100-410 Construction of power installations with rated voltages up to 1,000 V Part 4: Protective measures Chapter 41: Protection against electrical shock DIN EN 61204-1 Power supply units for low voltages, with direct-current-output – properties DIN EN 60947-1 Low-voltage switching devices – Part 1: General definitions DIN EN 61140 Protection against electrical shock - common requirements for facilities and operating equipment IEC 38 Supplementary notes relating to status of international standards and European harmonisation of mains voltages 230/400 V 73/23 EWG Electrical equipment for use within specific voltage limits (Low Voltage Directive) 2004/108/EG (89/336 EWG) Electromagnetic compatibility (EMC Directive) 2006/42/EG (98/37 EG) Safety of machines (directive covering mechanical equipment) UL Safety approval for the United States market CSA Safety approval for the Canadian market GL Test specifications for electrical/electronic devices and systems for use in marine technology UL1310 Class 2 power supplies (limited energy) UL1604 Electrical equipment for use in dangerous surroundings 1366860000 – 2013 Glossary/Technical appendix Standards and approvals Standard/Approval Description SEMI F47 Resistance of electronic devices against voltage drops 2006/95/EG (72/23/EWG) Low Voltage Directive EN 60721-3-2 Classification of surrounding conditions EN 60664-1 (VDE0110-1) Insulation coordination for electrical equipment C22.2 No. 107.1 General standards for power supplies (Canadian standard) EN 61000-3-2 Limiting of mains voltage harmonic currents EN 61000-4-x Interference immunity tests W 1366860000 – 2013 W.5 Glossary/Technical appendix Glossary Glossary A AC/DC converter Conventional switched-mode power supplies generate a DC voltage from an AC voltage. For this reason they are sometimes also called AC/DC converters. Such devices are increasingly compatible for use with DC input voltages. The primary and secondary sides are typically electrically isolated. Ambient temperature (operational) The ambient operating temperature (the min. and max. values) together with the output current and voltage ratings can be used to describe the power capabilities of a power supply unit. B Burst A burst is a quick low-power burst pulse which can, for example, simulate welding equipment phenomena. Similar phenomena can also result from switching operations on the mains supply. This test can be used to demonstrate immunity against quick transients. C W W.6 Class of protection Electrical equipment is classified according to varying classes of protection. These classes define the particular safety measures that are required to avoid an electrical shock. The most widely used power supplies correspond with protection class I. The basic requirement of protection class I is for a basic insulation and for the earthing of all conductive housing parts. If the basic insulation fails, then the earthed conductive housing serves to prevent an electrical shock. For this reason, devices in protection class I are equipped with an earth (PE) connection. Connecting power supply units in parallel Power supplies can only be connected in parallel when this is clearly permitted by the manufacturer. Parallel connections are then normally tied to certain conditions. This is a typical way to increase the output power (for example, when extending a facility). Power supplies are also wired in parallel in order to design redundant power supply systems. The parallel circuit is not wired straight though but connects using decoupling diodes. ➝ Redundancy Cooling Cooling is used by components or devices to prevent them from overheating. A variety of cooling strategies are available – two of the most common are natural and forced-air cooling. Natural (convection-based) cooling takes advantage of the natural air currents. Manufacturers must then ensure that there is sufficient air flow by specifying the clearance gaps and mounting positions that are required above and below the ventilation openings. Forced-air cooling normally uses a fan to dissipate any heat that has been generated. When fans are used in a device, they have the effect of increasing the likelihood of device outages. For this reason, a power supply with natural cooling methods is generally preferred. 1366860000 – 2013 Glossary/Technical appendix Glossary D DC/DC converter DC/DC converters are switched-mode power supplies that convert a specific DC voltage into another voltage. They are a variant of the AC/DC converter. DC/DC converters, in their simplest implementation, do not isolate voltage potentials. They are used only for adapting voltages. Improved DC/DC converters have isolated voltages. A safety isolating transformer in the power element ensures the required electrical isolation. Besides the voltage adaptation, the isolation of the voltage potentials is an important factor. Derating For power supply devices, derating generally refers to the reduction in power as influenced by the surrounding temperature and the input voltage. A temperature derating often occurs starting at a surrounding temperature of 50 °C. The rated power is guaranteed up to this temperature. The available power continually declines as the temperature heats up above this level. This is typically specified in %/K. A voltage-dependent specification is another form of derating For switched-mode power supplies, the derating begins below a specific input voltage. So a switched-mode power supply with a wide input range can typically work under full power with 115 V AC input voltage. However at 85 V AC it can only produce 60 % of the power rating. The coefficient is usually specified in %/V. Temperature derating 100 95 90 85 80 75 70 40 45 50 55 60 Temperature [°C] Diode modules 65 Voltage derating 120 Max. current [%IN] Max. current [%IN] 105 70 75 100 80 60 40 20 0 70 90 110 130 150 170 190 210 230 250 270 Main voltage [V] Diode modules are used to construct a redundant power supply system. They are important for decoupling the power supply unit. Thus, a short circuit that occurs on the output of a power supply unit will not influence the output voltage. E Efficiency The degree of efficiency is equal to the ratio of output power to input power and is expressed in percent. The degree of efficiency can be between 70 and 90 %, depending on the dimensions and type of technology in use. EMC (electromagnetic compatibility) Electromagnetic compatibility describes the interference emissions caused by an electronic device and the level of immunity against external electrical influences. Interference emissions can be caused by cabling and wires or by radiated emissions. Immunity measures the resistance against such wire-based emissions and against radiated emissions such as electrostatic fields and magnetic fields. Electric devices must also be protected against electrostatic discharges. 1366860000 – 2013 W W.7 Glossary/Technical appendix Glossary F Foldback characteristic curve The foldback characteristic curve is a special type of output curve that protects the power supply unit from overloads. When a specific current limit is exceeded (for example, by 110 or 120 % of the nominal level), the current is limited electronically and lowered to a very low, safe value. This downward-sloping characteristic curve means that it is not sufficient to simply eliminate the overload. The load must be reduced significantly more so that the adjustment control can return to the normal voltage control. Thus this solution is not suitable for many applications and is becoming less popular. U UA INominal I Limit I G Galvanic isolation Galvanic (electrical) isolation ensures that no electrical connections can exist between the primary and the secondary sides. Opto modules and transformers are the typical components used. H Hiccup mode The hiccup mode is a special output characteristic curve that protects power supply units from overloads and short circuits. The unit switches off at a specified current limit (for example, 110 or 120 % on the nominal rating) and then switches back on after a certain delay. This leads to a pulsating mode of operations which can only revert to continual operations after the overload has been eliminated. The main disadvantage here is that the connected consumer load must be restarted after every pause. A restart may not be possible with motors or large capacitive loads since the restart current peak may once again exceed the defined limit. U UA W t I ILimit INominal t W.8 1366860000 – 2013 Glossary/Technical appendix Glossary Hold-up time (mains-failure bridging time) The hold-up time (also known as the mains-failure bridging time) is the interval from the start of the mains outage to the point in time when the output voltage can no longer be maintained at its original level. The hold-up time indicates how long a mains outage may last before it influences the output voltage. For DC power supplies, EN 61204 requires a bridging time of at least 20 ms. U UA hold-up time Power failure (cutoff) t I Input voltage range This refers to the minimum and maximum input voltage at which the rated output specifications can be maintained. Inrush current The inrush current refers to the peak current that occurs when turning on a consumer load. Switched-mode power supplies have storage capacitors in the input which can cause significant current peaks while the mains power is being switched on. A variety of circuitry solutions can be used to attenuate these current peaks. In the simplest solution, an inrush limiter is used. Active switching can be used in other cases. The peak current specification indicates which upstream fuse should be used in the circuit. If a fuse is selected which is too sensitive, it can trigger when the mains power is switched on. W 1366860000 – 2013 W.9 Glossary/Technical appendix Glossary IU characteristic curve The IU characteristic curve is a special output characteristic curve that protects power supply units from overloads and short circuits. It offers the best performance with regards to overload and short circuit capabilities. A current limit is activated at a specific current level (for example, 110 or 120 % on the nominal rating). As the load continues to increase, the output voltage is reduced according to the current limit curve until it reaches a level approaching zero volts. Thus a pulsating mode of operations is avoided for short-term overloads. Large capacitive loads or motors are brought back up along the slope of the current-limit characteristic curve. After a short circuit or overload is fixed, the IU characteristic curve offers the advantage of immediately returning to the normal voltage control mechanism. The full output voltage is then immediately available. The IU characteristic curve is becoming the established standard for modern power supplies. Additional variants are available which pertain to the peak current capacity and the slope of the current-limit characteristic curve. U UA INominal I Limit I M Mains harmonics Power supplies can experience harmonics caused by mains rectification on the input side. These harmonics are multiples of the mains frequencies. Existing standards define specific limit values since such harmonics can significantly lower the mains quality. Mains system types This refers to the types of mains supply systems. Systems differ in their method of earthing and the implementation of the phase wire, PE wire and central-point wire. Common mains systems include the TN, IT and TT networks. The individual mains types can also differ in their voltage levels and frequencies. PRO-M PRO-M L N PE TN-S Mains L1 L2 L3 N PE W W.10 MTBF (mean time between failure) PRO-M L N PE TN-C Mains L1 L2 L3 PEN PRO-M L N PE TT Mains L1 L2 L3 N L N PE IT Mains L1 L2 L3 N The MTBF is a statistical value that specifies the probability that a product will fail. It is typically specified in hours and normally assumes a temperature of 25 °C. The probability of failure depends largely on the ambient surroundings. The key variables are the type of load and the ambient temperature. 1366860000 – 2013 Glossary/Technical appendix Glossary O Output characteristic curves The output characteristic curves of power supply devices are determined by current and voltage. Unregulated devices do not have a current limit. In the case of an overload or short circuit, fuses or temperature switches are used to protect the device. Regulated devices are protected against overload and short circuits by means of various output characteristic curves. In this case, the system attempts to prevent any activation of fuses or temperature switches. The mandatory manual reset which follows an overload or short circuit can then be avoided. Common output characteristic curves include the hiccup mode, the foldback characteristic curve or the IU characteristic curve. ➝ Hiccup mode, foldback characteristic curve, IU characteristic curve Overvoltage category Power supply units are classified into overvoltage categories according to the immunity against mains surges and transient voltages. P PELV (protective extra-low voltage) This is a functional DC voltage with secure isolation according to EN 50178. As with SELV, a reinforced or double insulation is used between the primary and secondary sides. However, the secondary side is earthed. PFC (power factor correction) The power factor correction can be either passive or active in relation to power supply devices. The reactive power resulting from the bridge rectification puts a significant strain on the power supply network. The relatively poor power efficiency factor that results can be improved by using passive components (such as filters) or an active electronic mechanism. For switched-mode power supplies, PFC usually refers to the active variant of the power factor correction. Power factors of almost 1 can be reached when using an active PFC. Practically no reactive power is drawn from the mains supply network; therefore the strain on the mains network is relatively low. Pollution severity Pollution severity describes the environment and ambient conditions that a device requires in order for it to function smoothly. Significant environmental variables include condensation or air containing dust and oil. Power-boost or boost The power-boost function is the surge current handling capacity in the seconds to minutes range. This function is often required for starting up DC motors. DC motors have a high start-up current and often require several seconds before they have achieved their rated rotational speed. The power-boost function helps to optimise this start-up phase. Power factor The power factor is the ratio of reactive power to apparent power. It is an indicator of the device performance with respect to the load on the mains power network. Depending on the technology in use, the power factor for power supplies can be between 0.45 and nearly 1. 1366860000 – 2013 W W.11 Glossary/Technical appendix Glossary Power loss For power supply units, the power loss specification indicates the thermal output emitted during nominal (rated) operations. This is a key specification used by engineers when designing the climate control systems within electrical cabinets. It is calculated as the difference between the input and output power and can also take the degree of efficiency into account. Power rating The continual output permitted under the rated conditions. Power supply units connected in series Power supplies can only be connected in series when this is clearly permitted by the manufacturer. Such series connections are then normally tied to certain conditions. They can be used to increase the output voltage. This is not widely implemented. Protection degree According to DIN EN 60529, devices can be classified according to their protection degrees. The numeric code (for example, IP 20) defines two protection degrees: protection against touch or penetration by external objects (the first digit) and protection against water penetration (the second digit). Switched-mode power supplies intended for use in electrical cabinets or similar enclosures are often designed with IP 20 protection. The first digit (in this case, 2) ensures finger protection. The second digit (0) indicates that no protection against water is provided. Pulsed current capacity The pulsed current capacity describes the dynamic performance of a switchedmode power supply. Capacitive consumer loads, with their high inrush currents, put a particular strain on a switched-mode power supply. Peak values are reached (in the ms range) which amount to levels many times higher than the mains current. If the current control mechanism reacts too quickly, this can lead to voltage drops and can cause problems for loads which are connected in parallel. For this reason, power supplies are often equipped with a surge current limiting factor based on time. This allows a high current output for only a few ms which can be much higher than the rated current. R W W.12 Rated control voltage The nominal value of the sparkover voltage for the relay. Rated input voltage The input voltage required at which, under the normal mains voltage fluctuations, the output levels can be kept stable. It usually corresponds to the rated voltage for the electric utility‘s power grid. Rated output current The long-term current permitted under the rated conditions. Rated output voltage The nominal output voltage used for the rated specifications. It usually corresponds to the factory default output voltage. 1366860000 – 2013 Glossary/Technical appendix Glossary Redundancy A power supply system is considered redundant if it is constructed so that it has partial power supplies which are independent of each other and each of these can individually deliver the output load. When a fault occurs, therefore, it is still possible to continue to supply the connected rated load. In reality, at least two power supplies are connected in parallel using decoupling diodes. In this way, a short circuit in the output of one power supply will not lead to the failure of the entire power supply system. ➝ Diode modules Regulated power supply units Switched-mode power supplies, as opposed to more common power supply units, have become established as the standard for the 10–1,000 W power range. They produce a stable output voltage with minimal residual ripple, even when influenced by fluctuations in the mains voltage, mains frequency or load. Their small size and weight is a result of their superior efficiency degree. The electronic control mechanism typically ensures a constant output voltage that varies ±1 %. Residual ripple The residual ripple describes the ratio of superimposed AC voltage to DC voltage on the output side of the power supplies. In addition to a percent specification, the superimposed ripple is often specified in mVSS for switched-mode power supplies. Resistance to shock Resistance to shock refers to mechanical immunity against impacts in any direction. This is a key factor while the product is being transported. Response time The response time is the time that a power supply unit needs to compensate for a disturbance (for example, a load fluctuation). S Switching frequency Switched-mode power supplies are normally operated with switching frequencies from 20 to 200 kHz. The HF or power transformer is switched on an off using transistors at this switching frequency. Small, compact units can be built with this method in comparison with the traditional 50/60 Hz transformers. W 1366860000 – 2013 W.13 Glossary/Technical appendix Glossary Switched-mode power supply units The switching pulse can be either primary or secondary. Thus there are primary switched-mode and secondary switched-mode power supply units. Secondary switched-mode power supply units are no longer of much significance. The primary switched-mode power supplies are now the focus of attention. The pulse refers to the high-frequency on and off switching of the transformer or transmitter in order to transmit energy. The high frequency allows the use of extra small inductive and capacitive components, particularly for the transmitter. In comparison to transformer-based power supply units, the weight and volume required are much reduced. L + – N PE Selectivity When surge protection equipment is connected in series, selectivity refers to the ability of only one upstream fuse to trigger selectively in the event of an overload. The differentiation can take into account current or also time. With DC power supply systems, selectivity refers to the separate fusing of load circuits on the DC side. In this case as well, only the proper series fuse should trigger in the event of an overload. Fuses in DC circuits play a critical role since the power supplies must react to upcoming short circuits with a speedy cut-off or by limiting the current. Usually electronic fuses are used for this purpose. Mains Mains 63 A 25 A ˜ = Power Supplies 16 A Load Selectivity for fuses connected in series W W.14 Load Load Load Selectivity for DC systems SELV (safety extra low voltage) SELV refers to extra-low safety voltages according to IEC/EN 60950. Reinforced or doubled insulation between the primary and secondary sides is used to prevent electric shock. The output voltage here is sufficiently low so that it does not pose an injury risk if a person comes into direct contact. Earthing on the secondary side is possible but not required. Surge A surge is a high-power voltage pulse which can be caused by, for example, a lightning strike. The switching operations from large consumer loads can also generate such voltage surges on the mains network. The surge test is used to demonstrate the immunity against high-power voltage pulses. 1366860000 – 2013 Glossary/Technical appendix Glossary T Temperature range The temperature range specifies the minimum and maximum ambient temperatures for which a device can start up and run continuously. U Unregulated power supply units Unregulated power supplies consist mainly of a transformer, a rectifier and an Elkos filter. Since no controlling system is in place, mains voltage fluctuations influence the DC voltage side. Unregulated power supply units are very sturdy; they can be used in applications where a stabilised DC voltage is not necessary (for example, power supply to contactors). V Vibration resistance Vibration resistance describes the resistance against constant mechanical vibrations that occur during operations. Rail and ship applications place stricter demands for vibration resistance on the device. W Wide-range input Modern switched-mode power supplies often feature a wide input range. They can be run under a wide range of voltages: from min. to max. rated voltages including the tolerance limits. They do not require any manual range switching. Status: 01.07.2012 W 1366860000 – 2013 W.15 W W.16 1366860000 – 2013 Glossary/Technical appendix Contents Index Index Index Index Type X.2 Index Order No. X.3 Addresses worldwide X.4 X 1366860000 – 2013 X.1 Type B BG GH 10P 4XVG PT6 BG GHDE 10P HO PT6 BG GHDE 10P PT6 BG SNT PT6 Index / Type C CP A BATTERY 24V DC12AH CP A BATTERY 24V DC17AH CP A BATTERY 24V DC3.4AH CP A BATTERY 24V DC7.2AH CP DC BUFFER 24V 20A CP DC UPS 24V 20A/10A CP DC UPS 24V 40A CP DCDC 250W 24V 10A CP DCDC 50W 12V 3A CP DCDC 50W 12V 3A CP DCDC 50W 15V 3A CP DCDC 50W 15V 3A CP DCDC 50W 22-24V 2A CP DCDC 50W 22-24V 2A CP DCDC 50W 5V 8A CP DM 10 CP DM 20 CP M CAP CP M CAP CP M DM20 CP M DM20 CP M DM40 CP M DM40 CP M RM24 CP M SNT 1000W 24V 40A CP M SNT 1000W 24V 40A CP M SNT 120W 24V 5A CP M SNT 120W 24V 5A CP M SNT 180W 24V 7,5A CP M SNT 180W 24V 7,5A CP M SNT 250W 24V 10A CP M SNT 250W 24V 10A CP M SNT 250W 24V 10AUW CP M SNT 500W 24V 20A CP M SNT 500W 24V 20A CP M SNT 70W 24V 3A CP M SNT 70W 24V 3A CP M SNT3 1000W 24V 40A CP M SNT3 1000W 24V 40A CP M SNT3 120W 24V 5A CP M SNT3 120W 24V 5A CP M SNT3 250W 24V 10A CP M SNT3 250W 24V 10A CP M SNT3 500W 24V 20A CP M SNT3 500W 24V 20A CP NT 144W 24V 6A CP NT 192W 24V 8A CP NT 264W 24V 11A CP NT 36W 24V 1.5A CP NT 432W 24V 18A CP NT 72W 24V 3A CP NT3 1000W 24V 40A CP NT3 250W 24V 10A CP NT3 400W 24V 15A CP NT3 500W 24V 20A CP NT3 600W 24V 25A CP NT3 750W 24V 30A CP SNT 1000W 24V 40A CP SNT 120W 24V 5A CP SNT 12W 24V 0.5A CP SNT 160W 12-15V 8A CP SNT 160W 24-28V 6.5A CP SNT 160W 48V 3.5A CP SNT 160W 5V 8A CP SNT 24W 12V 1.5A CP SNT 24W 15V 1.5A CP SNT 24W 24V 1A CP SNT 24W 28V 1A CP SNT 24W 5V 2A CP SNT 250W 24V 10A CP SNT 25W 5V 5A CP SNT 300W 24V 12.5A CP SNT 48W 12V 4A CP SNT 48W 24V 2A CP SNT 48W 48V 1A CP SNT 500W 24V 20A CP SNT 55W 12-15V 3A CP SNT 55W 24-28V 2.3A CP SNT 55W 48V 1.04A CP SNT 55W 5V 3A CP SNT 70W 24V 3A CP SNT3 1000W 24V 40A CP SNT3 120W 24V 5A CP SNT3 250W 24V 10A CP SNT3 500W 24V 20A CP T RM 10 CP T RM 20 CP T SNT 140W 12V 12A CP T SNT 180W 24V 7,5A CP T SNT 180W 48V 4A X X.2 Order No. Page 1121990000 1121950000 1122200000 1101940000 E.10 E.11 E.11 E.7 1251090000 1251110000 1251070000 1251080000 1251220000 1370050010 1370040010 1313320010 9919371212 9919372412 9919371215 9919372415 9919371224 9919372424 9919372405 8710620000 8768650000 1222240000 1222240010 1222210000 1222210010 1222220000 1222220010 1222230000 8951380000 8951380010 8951340000 8951340010 8951350000 8951350010 8951360000 8951360010 1165480010 8951370000 8951370010 8951330000 8951330010 8951420000 8951420010 8951390000 8951390010 8951400000 8951400010 8951410000 8951410010 8575280000 8575300000 8575310000 8575260000 8575320000 8575270000 8628680000 8628620000 8628630000 8628650000 8628660000 8628670000 8862780000 8708670000 9918840024 9925340012 9925340024 9925340048 9925340005 9928890012 9928890015 9928890024 9928890028 9928890005 8708680000 8754960000 9916250024 8754970000 8739140000 8879230000 8778870000 9927480012 9927480024 9927480048 9927480005 8708660000 8708730000 8862730000 8708700000 8708710000 1105880000 1105890000 1105440000 1105810000 1105850000 B.7 B.7 B.6 B.6 B.8 B.5 B.5 A.57 A.53 A.54 A.53 A.52 A.53 A.52 A.54 A.37 A.37 A.12 A.12 A.10 A.10 A.10 A.10 A.11 A.7 A.7 A.5 A.5 A.6 A.6 A.6 A.6 A.15 A.7 A.7 A.5 A.5 A.9 A.9 A.8 A.8 A.8 A.8 A.9 A.9 D.5 D.5 D.6 D.4 D.6 D.4 D.9 D.7 D.7 D.8 D.8 D.9 A.32 A.29 A.45 A.49 A.48 A.48 A.49 A.39 A.39 A.38 A.38 A.40 A.30 A.41 A.50 A.42 A.43 A.44 A.31 A.47 A.46 A.46 A.47 A.28 A.36 A.33 A.34 A.35 A.25 A.25 A.17 A.19 A.21 Type CP T SNT 360W 24V 15A CP T SNT 360W 48V 7,5A CP T SNT 600W 24V 25A CP T SNT 600W 36V 16,5A CP T SNT 600W 48V 12,5A CP T SNT 70W 12V 6A CP T SNT 90W 24V 3,8A CP T SNT 90W 24V3,8ACL2 CP T SNT 90W 48V 2A CP T SNT2 180 W 24 V 7,5 A CP T SNT2 360 W 24 V 15 A CP T SNT2 600 W 24 V 25 A CP-SNT 380-480VAC/24V D DG D0 PT6 F FP Box 10P SNT FP Box 10P SNT 4XVG G GH 10P PT6 P PT6 PT6 230/BUS PT6 DC PTDS 4 PTDS 4 DC PTS 4 PTS 4 DC PTS 4 MPB PTSI 4/LD 36V AC/DC PTSI 4/LD 400V AC R RKDG D11 PT6 RKDG D13 PT6 RKDG D15 PT6 RKDG D17 PT6 RKDG D9 PT6 S Schuko TS35 T TS 35 PT6 W WGS 24Vdc 0.5...5A WGS 24Vdc 1,6A WGS 24Vdc 3,15A WGS 24Vdc 6,3A WGS 24Vdc 8,0A WGZ 24Vdc 0.5...5A WGZ 24Vdc 1,6A WGZ 24Vdc 3,15A WGZ 24Vdc 6,3A WGZ 24VDC 8,0A Order No. Page 1105820000 1105860000 1105840000 1194430000 1105870000 1105430000 1105790000 1194410000 1194420000 1194480000 1194490000 1194310000 9917790324 A.19 A.22 A.20 A.20 A.22 A.17 A.18 A.18 A.21 A.23 A.23 A.24 A.51 4323240000 E.12 1132320000 1076510000 E.6 E.6 1121980000 E.10 1957620000E.14 1269960000 E.15 1126840000 E.14 1952130000 E.16 1009990000 E.17 1952120000 E.16 1131730000 E.17 1010910000 E.18 1252210000 E.19 1961770000 E.19 4323210000 4323230000 4323220000 4324010000 4329610000 E.12 E.12 E.12 E.12 E.12 8734580000 E.24 1170690000 E.10 8710270000 8618890000 8618910000 8618930000 8618940000 8727630000 8621040000 8621030000 8621020000 8621010000 C.6 C.4 C.4 C.5 C.5 C.6 C.4 C.4 C.5 C.5 1366860000 – 2013 Type 1000000000 1009990000 PTDS 4 DC 1010000000 1010910000 PTS 4 MPB 1070000000 1076510000 FP Box 10P SNT 4XVG 1100000000 1101940000 1105430000 1105440000 1105790000 1105810000 1105820000 1105840000 1105850000 1105860000 1105870000 1105880000 1105890000 BG SNT PT6 CP T SNT 70W 12V 6A CP T SNT 140W 12V 12A CP T SNT 90W 24V 3,8A CP T SNT 180W 24V 7,5A CP T SNT 360W 24V 15A CP T SNT 600W 24V 25A CP T SNT 180W 48V 4A CP T SNT 360W 48V 7,5A CP T SNT 600W 48V 12,5A CP T RM 10 CP T RM 20 1120000000 1121950000 1121980000 1121990000 1122200000 1126840000 BG GHDE 10P HO PT6 GH 10P PT6 BG GH 10P 4XVG PT6 BG GHDE 10P PT6 PT6 DC 1130000000 1131730000 PTS 4 DC 1132320000 FP Box 10P SNT 1160000000 1165480010 CP M SNT 250W 24V 10AUW 1170000000 1170690000 TS 35 PT6 1190000000 1194310000 1194410000 1194420000 1194430000 1194480000 1194490000 CP T SNT2 600 W 24 V 25 A CP T SNT 90W 24V3,8ACL2 CP T SNT 90W 48V 2A CP T SNT 600W 36V 16,5A CP T SNT2 180 W 24 V 7,5 A CP T SNT2 360 W 24 V 15 A 1220000000 1222210000 1222210010 1222220000 1222220010 1222230000 1222240000 1222240010 CP M DM20 CP M DM20 CP M DM40 CP M DM40 CP M RM24 CP M CAP CP M CAP 1250000000 1251070000 1251080000 1251090000 1251110000 1251220000 1252210000 CP A BATTERY 24V DC3.4AH CP A BATTERY 24V DC7.2AH CP A BATTERY 24V DC12AH CP A BATTERY 24V DC17AH CP DC BUFFER 24V 20A PTSI 4/LD 36V AC/DC 1260000000 1269960000 PT6 230/BUS 1310000000 1313320010 CP DCDC 250W 24V 10A 1370000000 1370040010 CP DC UPS 24V 40A 1370050010 CP DC UPS 24V 20A/10A 1950000000 1952120000 PTS 4 1952130000 PTDS 4 1957620000PT6 1960000000 1961770000 PTSI 4/LD 400V AC 1366860000 – 2013 Page E.17 E.18 E.6 E.7 A.17 A.17 A.18 A.19 A.19 A.20 A.21 A.22 A.22 A.25 A.25 E.11 E.10 E.10 E.11 E.14 E.17 E.6 A.15 E.10 A.24 A.18 A.21 A.20 A.23 A.23 A.10 A.10 A.10 A.10 A.11 A.12 A.12 B.6 B.6 B.7 B.7 B.8 E.19 E.15 A.57 B.5 B.5 E.16 E.16 E.14 E.19 Order No. Type 4320000000 4323210000 4323220000 4323230000 4323240000 4324010000 4329610000 RKDG D11 PT6 RKDG D15 PT6 RKDG D13 PT6 DG D0 PT6 RKDG D17 PT6 RKDG D9 PT6 8570000000 8575260000 8575270000 8575280000 8575300000 8575310000 8575320000 CP NT 36W 24V 1.5A CP NT 72W 24V 3A CP NT 144W 24V 6A CP NT 192W 24V 8A CP NT 264W 24V 11A CP NT 432W 24V 18A 8610000000 8618890000 8618910000 8618930000 8618940000 WGS 24Vdc 1,6A WGS 24Vdc 3,15A WGS 24Vdc 6,3A WGS 24Vdc 8,0A 8620000000 8621010000 8621020000 8621030000 8621040000 8628620000 8628630000 8628650000 8628660000 8628670000 8628680000 WGZ 24VDC 8,0A WGZ 24Vdc 6,3A WGZ 24Vdc 3,15A WGZ 24Vdc 1,6A CP NT3 250W 24V 10A CP NT3 400W 24V 15A CP NT3 500W 24V 20A CP NT3 600W 24V 25A CP NT3 750W 24V 30A CP NT3 1000W 24V 40A 8700000000 8708660000 8708670000 8708680000 8708700000 8708710000 8708730000 CP SNT 70W 24V 3A CP SNT 120W 24V 5A CP SNT 250W 24V 10A CP SNT3 250W 24V 10A CP SNT3 500W 24V 20A CP SNT3 1000W 24V 40A 8710000000 8710270000 WGS 24Vdc 0.5...5A 8710620000 CP DM 10 8720000000 8727630000 WGZ 24Vdc 0.5...5A 8730000000 8734580000 Schuko TS35 8739140000 CP SNT 48W 24V 2A 8750000000 8754960000 CP SNT 25W 5V 5A 8754970000 CP SNT 48W 12V 4A 8760000000 8768650000 CP DM 20 8770000000 8778870000 CP SNT 500W 24V 20A 8860000000 8862730000 CP SNT3 120W 24V 5A 8862780000 CP SNT 1000W 24V 40A 8870000000 8879230000 CP SNT 48W 48V 1A 8950000000 8951330000 8951330010 8951340000 8951340010 8951350000 8951350010 8951360000 8951360010 8951370000 8951370010 8951380000 8951380010 8951390000 8951390010 CP M SNT 70W 24V 3A CP M SNT 70W 24V 3A CP M SNT 120W 24V 5A CP M SNT 120W 24V 5A CP M SNT 180W 24V 7,5A CP M SNT 180W 24V 7,5A CP M SNT 250W 24V 10A CP M SNT 250W 24V 10A CP M SNT 500W 24V 20A CP M SNT 500W 24V 20A CP M SNT 1000W 24V 40A CP M SNT 1000W 24V 40A CP M SNT3 120W 24V 5A CP M SNT3 120W 24V 5A Page E.12 E.12 E.12 E.12 E.12 E.12 D.4 D.4 D.5 D.5 D.6 D.6 C.4 C.4 C.5 C.5 C.5 C.5 C.4 C.4 D.7 D.7 D.8 D.8 D.9 D.9 Order No. 8951400000 8951400010 8951410000 8951410010 8951420000 8951420010 Type CP M SNT3 250W 24V 10A CP M SNT3 250W 24V 10A CP M SNT3 500W 24V 20A CP M SNT3 500W 24V 20A CP M SNT3 1000W 24V 40A CP M SNT3 1000W 24V 40A 9910000000 9916250024 9917790324 9918840024 9919371212 9919371215 9919371224 9919372405 9919372412 9919372415 9919372424 CP SNT 300W 24V 12.5A CP-SNT 380-480VAC/24V CP SNT 12W 24V 0.5A CP DCDC 50W 12V 3A CP DCDC 50W 15V 3A CP DCDC 50W 22-24V 2A CP DCDC 50W 5V 8A CP DCDC 50W 12V 3A CP DCDC 50W 15V 3A CP DCDC 50W 22-24V 2A 9920000000 9925340005 9925340012 9925340024 9925340048 9927480005 9927480012 9927480024 9927480048 9928890005 9928890012 9928890015 9928890024 9928890028 CP SNT 160W 5V 8A CP SNT 160W 12-15V 8A CP SNT 160W 24-28V 6.5A CP SNT 160W 48V 3.5A CP SNT 55W 5V 3A CP SNT 55W 12-15V 3A CP SNT 55W 24-28V 2.3A CP SNT 55W 48V 1.04A CP SNT 24W 5V 2A CP SNT 24W 12V 1.5A CP SNT 24W 15V 1.5A CP SNT 24W 24V 1A CP SNT 24W 28V 1A Page A.8 A.8 A.9 A.9 A.9 A.9 Index / Order No. Order No. A.50 A.51 A.45 A.53 A.53 A.53 A.54 A.54 A.52 A.52 A.49 A.49 A.48 A.48 A.47 A.47 A.46 A.46 A.40 A.39 A.39 A.38 A.38 A.28 A.29 A.30 A.34 A.35 A.36 C.6 A.37 C.6 E.24 A.43 A.41 A.42 A.37 A.31 A.33 A.32 A.44 A.5 A.5 A.5 A.5 A.6 A.6 A.6 A.6 A.7 A.7 A.7 A.7 A.8 A.8 X X.3 Addresses worldwide Addresses worldwide AE United Arab Emirates Weidmuller Middle East FZE P.O. Box 8591, SAIF-Zone Sharjah U. A. E. Phone +971 6 5572723 Fax +971 6 5572724 [email protected] AR Argentina CPI SA Bauness 2660 1431 Buenos Aires Phone +54 11 45238008 Fax +54 11 45220546 [email protected] www.cpi.com.ar AT AU AZ BA BY Belarus Technikon Ltd. Nezavisimosti pr.177-9 Minsk 220125 Phone +375 17 3931177 Fax +375 17 3930080 [email protected] CA Canada W Interconnections CANADA Ltd. 10 Spy Court, Markham, Ontario L3 R5 H6 Phone +1 905 475-1507 Fax +1 905 475-2798 [email protected] www.weidmuller.ca Austria Weidmüller GmbH Austria Straße 2, Industriezentrum Nö Süd Straße 2b M59 2355 Wiener Neudorf Phone +43 2236 6708-0 Fax +43 2236 6708-199 [email protected] CH Australia Weidmüller Pty. Ltd. P.O.Box 6944 Huntingwood Drive 43 Huntingwood, NSW, 2148 Phone +61 2 9671-9999 Fax +61 2 9671-9911 [email protected] www.weidmuller.com.au CL Azerbaijan West Industries Ltd. Caspian Plaza, 5-th Floor 44 J. Jabbarly Str., Baku Phone +99412 596 15 15 Fax +99412 596 14 93 [email protected] Bosnia and Herzegovina Representative Office Weidmüller Interface GmbH & Co. KG Beograd-Stari Grad Danice Marković 2 11050 Beograd Srbija Phone +381 11 288 5274 Fax +381 11 288 5274 zoran.rabrenovic@ weidmueller.com CO BH ES ELEKTROSISTEM d.o.o. Bul. Vojvode S. Stepanovica kod br. 272 78000 BiH - Banja Luka Phone +387 51 420-340 Fax +387 51 420-341 [email protected] www.elektrosistem.ba BE Belgium Weidmüller Benelux B.V. Mechelsesteenweg 519 bus 6 en 7 1930 Nossegem Phone +32 2 752 4070 Fax +32 2 751 3606 [email protected] www.weidmueller.be CR Bulgaria Weid-Bul EOOD 1756 Sofia 13, bul. "Kliment Ohridski" Phone +359 2 9632560 Fax +359 2 9631098 [email protected] www.weidbul.com CZ BH Bahrain Khayber Trading Company P.O. Box 1976 Manama, Phone +973 720747 Fax +973 720331 [email protected] DE BR Brazil Weidmüller Conexel do Brasil Conexões Elétricas Ltda. Rua Garcia Lorca, 176 09695-900, Sao Paulo SP Phone +55 11 43669600 Fax +55 11 43621677 [email protected] www.weidmueller.com.br BG X X.4 X.2 DK Ecuador Elsystec S. A. Electricidad Sistemas y Tecnología Vasco de Contreras N35-25 y Mañosca, Quito Phone +593 2 2456510 Fax +593 2 2456755 [email protected] EE Estonia Representative Office Weidmüller Interface GmbH & Co. KG Udens str. 12-118 Riga, LV-1007 Latvia Phone +371 29254766 Fax +371 67624562 ilgonis.rudaks@ weidmueller.com Switzerland Weidmüller Schweiz AG Rundbuckstraße 2 8212 Neuhausen am Rheinfall Phone +41 52 6740707 Fax +41 52 6740708 [email protected] www.weidmueller.ch Chile Felipe Bahamondes S.A./ ATS AGRO Maria Luisa Santander 0475 Casilla 3425 Santiago Phone +56 2 341-1271 Fax +56 2 341-1275 [email protected] CPI CHILE LTDA Av. Presidente Frei Montalva 6001-47, Conchali Region Metropolitana Santiago [email protected] CN EC China Weidmüller Interface International Trading (Shanghai) Co., Ltd. 25F, BM Intercontinental Business Center, 100 Yutong Road,Shanghai 200070 P.R. China Phone +86 21 22195008 Fax +86 21 22195009 www.cnweidmuller.com Colombia Automatización Avanzada S. A. Carrera 97 No.24c, 23 B4 4 Bogotá D. C. Phone +57 1 5478510 Fax +57 1 4223044 comercial@ automatizacionavanzada.com www. automatizacionavanzada.com Soots Interface OÜ Pärnu mnt 142 11317 Tallinn Phone +372 5296177 Fax +372 6096933 [email protected] www.sootsinterface.ee EG ES Fl FR GB Costa Rica ELVATRON S.A. la Uruca 400 Norte Banco Costa Rica San José Costa Rica Phone +506 2 961060 Fax +506 5 200609 [email protected] www.elvatron.com Czech Republic Weidmüller s. r. o. Lomnického 5/1705 14000 Praha 4 Phone +420 2 44001400 Fax +420 2 44001499 [email protected] www.weidmueller.cz Germany Weidmüller GmbH & Co. KG Postfach 3054 32720 Detmold Ohmstraße 9 32758 Detmold Phone +49 5231 1428-0 Fax +49 5231 1428-116 [email protected] www.weidmueller.de Denmark Wexøe A/S Lejrvej 31 3500 Vaerloese Phone +45 45465800 Fax +45 45465801 [email protected] www.wexoe.dk GR HR Hungary Weidmüller Kft Gubacsi út 6 1097 Budapest Phone +36 1 3827700 Fax +36 1 3827701 [email protected] ID Indonesia PT. Nego Electrindo Ruko Mega Grosir Cempaka Mas, Blok I No 20 – 22 Jl. Let.Jend. Suprato – Jakarta 10640 Phone +62 21 42882255 Fax +62 21 42882266 [email protected] IE Ireland Please contact Weidmüller Ltd. in Great Britain IL Israel A.U.Shay Ltd. P.O. Box 10049 Embar Street 23/25 49222 Petach-Tikva Phone +972 3 9233601 Fax +972 3 9234601 Egypt Standard Electric (OMEGA) 87, Mohamed Farid Street Heliopolis, Cairo Phone +20 26422977 Fax +20 26422955 [email protected] Spain Weidmüller S. A. Narcis Monturiol 11-13 Pol. Ind. Sudoeste 08960 Sant Just Desvern Barcelona Phone +34 93 4803386 Fax +34 93 3718055 [email protected] www.weidmuller.es Finland JUHA-ELEKTRO OY P. O. Box 57, 641 Helsinki Kylvöpolku 6, 680 Helsinki Phone +358 10 8328 100 Fax +358 10 8328 109 [email protected] www.juha-elektro.fi France Weidmüller E. U. R. L. 12, Chaussée Jules César B.P. 263 Osny 95523 Cergy Pontoise Cedex Phone +33 1 34245500 Fax +33 1 34245501 [email protected] Great Britain Weidmüller Ltd Klippon House Centurion Court Office Meridian East, Meridian Business Park Leicester, LE19 1TP Phone +44 1162 823470 Fax +44 1162 893582 [email protected] www.weidmuller.co.uk Greece Electrorama S.A. 1 An. Martali Str. 41335 Larissa Phone +30 2410 552533188 Fax +30 2410 283463189 [email protected] GA Contact Solutions 11, Ippokratous Str. 14452 Metamorfosi Attika Phone +30 210 2823233 Fax +30 210 2823233 [email protected] HK HU Hong Kong Weidmuller (Hong Kong) Limited Unit 1617, The Metropolis Tower, No.10, Metropolis Drive, Hunghom, Kowloon Phone +852 31548082 Fax +852 31548099 [email protected] Hong Kong ATEKA Ltd. 4, Ha‘Tavor lane Industrial area Segula 49691 Petach-Tikva Phone +972 73 2001311 Fax +972 3 9244245 [email protected] www.ateka.co.il IN IS IT India Weidmuller Electronics India Pvt. Ltd Plot # 32, 3rd Floor, North Court Lane North Avenue, Opp Jogger's Park Kalyani Nagar, Maharastra 411006 Pune Phone +91 9049800960 [email protected] Italy Weidmüller S.R.L. Via Albert Einstein 4 20092 Cinisello Balsamo Milano Phone +39 02 660681 Fax +39 02 6124945 [email protected] www.weidmuller.it Jordan HORIZONS P.O.Box: 330607 Amman Jordan 11133 Phone +962 6 4882114 Fax +962 6 4882115 [email protected] JP Japan Nihon Weidmüller Co. Ltd. Sphere Tower Tennoz, 2-2-8 Higashi-Shinagawa, Shinagawa-Ku, Tokyo 140-0002 Phone +81 3 6711-5300 Fax +81 3 6711-5333 www.weidmuller.co.jp Korea Weidmuller Korea Co. Ltd. 6F Seokyoung B/D, 242-54 Nonhyun-dong, Gangnam-gu Seoul, 135-830 Phone +82 2 5160003 Fax +82 2 5160090 [email protected] Kuwait KANA CONTROLS General Trading & Cont. CO. W.L.L. Al Rai Industrial Area, Plot 28-30, St. 31 P.O.Box: 25593 Safat, 13016 Phone +966-474 1373/4 Fax +966-474 1537 [email protected] LB Lebanon Progress Engineering & Trading Enterprises Al Nahr Street, Beirut Phone +961 1 444664 Fax +961 1 561880 [email protected] LT Lithuania Representative Office Weidmüller Interface GmbH & Co. KG Udens str. 12-118 Riga, LV-1007 Latvia Phone +371 29254766 Fax +371 67624562 ilgonis.rudaks@ weidmueller.com ELEKTROS IRANGA Tinklu g.29a, 5319 Panevezys Phone +370 45582828 Fax +370 45582727 [email protected] LU Luxembourg Please contact Weidmüller Benelux B.V. in the Netherlands LV Latvia Representative Office Weidmüller Interface GmbH & Co. KG Udens str. 12-118 Riga, LV-1007 Latvia Phone +371 29254766 Fax +371 67624562 ilgonis.rudaks@ weidmueller.com Iceland Samey Automation Center Lyngas 13, 210 Garoabaer, Phone +354 510 5200 Fax +354 510 5201 [email protected] JO KR KW SIA "ABI4" Daugavgrivas str. 31b 1007 Riga Phone +371 67470999 Fax +371 67465637 [email protected] MD Moldova BERHORD A&D srl 44, srt. Sarmizegetusa 37/3 Off 414. b-dul Decebal, 3, Chisinau, MD 2001 Phone +373 22 507137 Fax +373 22 507134 [email protected] ME Montenegro Representative Office Weidmüller Interface GmbH & Co. KG Beograd-Stari Grad Danice Marković 2 11050 Beograd Srbija Phone +381 11 288 5274 Fax +381 11 288 5274 zoran.rabrenovic@ weidmueller.com MK Macedonia Representative Office Weidmüller Interface GmbH & Co. KG Beograd-Stari Grad Danice Marković 2 11050 Beograd Srbija Phone +381 11 288 5274 Fax +381 11 288 5274 zoran.rabrenovic@ weidmueller.com ELEKTRO – SMK dooel UL. III Makedonska brigada b.b. 1000 Skopje Phone +389 22 460 295 Fax +389 22 460 298 [email protected] Croatia Elektro Partner d.o.o. Slavonska Avenija 24/6 10000 Zagreb Phone +385 1 6184793 Fax +385 1 6184795 [email protected] 1366860000 – 2013 MT Malta E. S. S., Electrical Supplies & Services Ltd 104 J. Sciberras Str. Hamrun HMR 08 Phone +356 21 255 777 Fax +356 21 255 999 [email protected] MU Mauritius MUBELO Electrical Ltd Office 26, Gateway building, St Jean Road, Quatre Bornes Phone +230 467 0989 Fax +230 465 4051 [email protected] MX MY NL NO NZ Mexico W Interconnections, S.A. DE C.V. Blvd. Hermanos Serdán No. 698 Col. San Rafael Oriente Puebla, C.P. 72029 Phone +52 222 22686227 [email protected] Malaysia Connect Plus Technology Sdn Bhd No. 43, Jalan PJS, 11/22, Bandar Sunway, 46150 Petaling Jaya Selangor Darul Ehsan Phone +60 3 5633 7363 Fax +60 3-5633 6562 [email protected] www.cptech.com.my Netherlands Weidmüller Benelux B.V. Franciscusweg 221 1216 SE Hilversum Postbus 1505 1200 BM Hilversum Phone +31 35 6261261 Fax +31 35 6232044 [email protected] www.weidmuller.nl Norway Siv. Ing. J. F. Knudtzen A/S Billingstadsletta 97 P.O. Box 160 1378 Nesbru Phone +47 66 983350 Fax +47 66 980955 [email protected] www.jfknudtzen.no PK Pakistan Kana Controls (Pak) Apartment No. 33 C III Chenab Block, Allama Iqbal Town Lahore, Pakistan Phone +92 42 5419948 +92 42 7845160 Fax +92 42 5422895 [email protected] www.kanapak.com PL Poland Weidmüller Sp. z o.o. Ul. Goledzinowska 10 03-302 Warszawa Phone +48 22 5100940 Fax +48 22 5100941 [email protected] www.weidmuller.pl PT QA RO RS New Zealand Cuthbert S. Steward Limited 27 Te Puni Street POB 38496 Petone, Wellington Phone +64 4 5686156 Fax +64 4 5686056 [email protected] OM Oman DAN INTERNATIONAL LLC. PO.BOX 2901 111 Seeb Phone +968 503 677 Fax +968 503 755 [email protected] PE Peru IMPEXINCA S.A.C. Calle Ortiz de Zevallos N°105, 18 Lima, Miraflores, Phone +511 447 5608 [email protected] Philippines Enclosure Systems Specialists Inc Room 103 Narra Building 2276 Don Chino Roces Avenue Makati City 1231 Phone +63 2 813 8580 Fax +63 2 813 8596 [email protected] 1366860000 – 2013 Qatar Doha Motors Trading Co. (Technical Division) Post Box No. 145 Airport Road Doha - Qatar Phone +974 465 1441 Fax +974 465 0925 [email protected] Serbia Representative Office Weidmüller Interface GmbH & Co. KG Ustanicka 189, III sprat, lokal 7a 11050 Beograd Phone +381 11 288 5274 Fax +381 11 288 5274 zoran.rabrenovic@ weidmueller.com RU Russia OOO Weidmüller Warshavskoye highway, 25A, bld. 6 117105 Moskau Phone +7 4 95 771-6940 Fax +7 4 95 771-6941 [email protected] www.weidmueller.ru SA Saudi-Arabia Al Abdulkarim Holding Co. P.O Box. 4 Dammam 31411 Phone +9668337110 Fax +9668338242 [email protected] www.weidmueller.ae Saudi Electric Supply Co. P.O. Box 3298 Al Khobar 31952 Phone +966 3 882 9546227 Fax +966 3 882 9547 [email protected] SE Singapore Weidmuller Pte. Ltd. 70 Bendemeer Road #04-03 Luzerne Singapore 339940 Phone +65 6841 5311 Fax +65 6841 5377 [email protected] www.weidmuller.com.sg SI Slovenia ELEKTROSPOJI d.o.o. Stegne 25, 1000 Ljubljana Phone +386 15113810 Fax +386 15111604 [email protected] www.elektrospoji.si SK TH Sweden Weidmüller AB Axel Daniessons väg 271 P.O. box 31025 200 49 Malmö Phone +46 (0) 7 71 43 00 44 Fax +46 (0) 40 37 48 60 [email protected] www.weidmuller.se Thailand Pisanu Engineering Co., Ltd 800/43-45 Soi Trakulsuk Asoke-dindaeng Road, Dindaeng, Bangkok 10400 Phone +66 2 245 9113 Fax +66 2 6429220 [email protected] www.pisanu.co.th Tunisia Please contact Weidmüller E.U.R.L. in France TR Turkey Weidmüller Elektronik Ticaret Ltd. Sirketi Kavacik Mah. Orhan Veli Kanik Caddesi 9/1 34810 Beykoz – Istanbul Phone +90 216 5371070 (Pbx) Fax +90 216 5371077 [email protected] www.weidmuller.com.tr TW VE Venezuela Somerinca C.A. Quinta Sagrado Corazon de Jesus 3ra Transversal Los Dos Caminos, Caracas 1070 - A Phone +58 212 2352748 Fax +58 212 2399341 [email protected] www.kmsomerinca.com.ve VN Vietnam AUMI Co., Ltd E1, La Thanh Hotel, 218 Doi Can Street, Lieu Giai Ward, Ba Dinh District, Hanoi City Phone +84 4762 8601 Fax +84 4266 1391 [email protected] Slovakia ELEKTRIS s.r.o. Elektrárenská 1 83104 Bratislava Phone +421 2 49200113 Fax +421 2 49200119 [email protected] TN Romania Rominterface Impex SRL Str. Gh. Dem Teodorescu 30 A 30916 Bucuresti - sector 3 Phone +40 21 3220230 Fax +40 21 3228857 [email protected] ES-YU Elektrosistem Pariske komune 41 11070 Novi Beograd, Serbia Phone +381 11 3018660 Fax +381 11 2693608 [email protected] J & W CIA. S.A. Calle 6 Mz. D Lte. 23 Urb. Ind. Grimanesa Callao 01 Phone +51 1 57 22539 Fax +51 1 57 20152 [email protected] www.jwcia.com PH Portugal Weidmüller Sistemas de Interface S. A. Estrada Outeiro Polima, R. Augusto Dias da Silva, Lote B, Esct. 2 2785-515 Abóboda -São Domingos de Rana Phone +351 21 4459191 Fax +351 21 4455871 www.weidmueller.pt SG Taiwan Fittatek Co., Ltd. 12F No. 185 Fu-Kuo Road, Tso Ying Dist, Kaohsiung Phone +886 7 556 0858 Fax +886 7 556 3279 [email protected] www.fittatek.com.tw DE Agency abroad DE Without own Agency DE Addresses worldwide Group companies Linh Kim Hai Co,. Ltd 78 Hoa Cuc Street Ward 7, Phu Bhuan District, Ho Chi Minh City Phone +84 8517 1717 Fax +84 8517 1818 [email protected] ZA South Africa Phambili Interface (Pty) Ltd P.O. Box 193, 1609 Johannesburg 5 Bundo Road, Sebenza 1610 Johannesburg, Endenvale Phone +27 11 452 1930 Fax +27 11 452 6455 [email protected] www.radinterface.co.za DE Other countries Weidmüller Interface GmbH & Co. KG Postfach 3030 32720 Detmold Klingenbergstraße 16 32758 Detmold Phone +49 5231 14-0 Fax +49 5231 14-292083 [email protected] www.weidmueller.com Eucan Enterprise Ltd. No. 145 He Ping 2nd Rd Kaohsiung Phone +886 7 715 6610 Fax +886 7 715 8748 [email protected] www.eucan.com.tw UA Ukraine TEKO INTERFACE Lomonosova str. 73g 03022 Kiev Phone +38 044 3740640 Fax +38 044 3740642 [email protected] www.tekointerface.com.ua US United States W-Interconnections Inc. 821 Southlake Boulevard, Virginia - Richmond 23236 Phone +1 804 7942877 Fax +1 804 3792593 [email protected] www.weidmuller.com UY Uruguay REWO Uruguay S.A AV. Bolivia 2001 Esq Rocafuerte Carrasco Montevideo 11300 Phone / Fax +598 260 48439 [email protected] UZ Usbekistan OOO “Elektro Potential” Gani Mavljanova str., 2B 100084 Tashkent Phone +998 98-3003821 Fax +998 71-1249286 [email protected] X X.5 X.3 Index We cannot guarantee that there are no mistakes in the publications or software provided by us to the customer for the purpose of making orders. We try our best to quickly correct errors in our printed media. X All orders are based on our general terms of delivery, which can be reviewed on the websites of our group companies where you place your order. On demand we can also send the general terms of delivery to you. X.6 1366860000 – 2013 Weidmüller – Partner in Industrial Connectivity As experienced experts we support our customers and partners around the world with products, solutions and services in the industrial environment of power, signal and data. We are at home in their industries and markets and know the technological challenges of tomorrow. We are therefore continuously developing innovative, sustainable and useful solutions for their individual needs. Together we set standards in Industrial Connectivity. Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 32758 Detmold, Germany T +49 5231 14-0 F +49 5231 14-292083 [email protected] www.weidmueller.com Order number: 1366860000/11/2012/SMDM