RH1034-1.2 - SPEC NO. 05-08-5229

SPEC NO. 05-08-5229 REV. C
REV
0
A
B
C
RH1034M-1.2, MICROPOWER DUAL REFERENCE
REVISION RECORD
DESCRIPTION
DATE
04/08/08
INITIAL RELEASE
CHANGED PART NUMBER FROM “RH1034-1.2M” TO “RH1034M-1.2” THROUGH OUT SPEC.
PAGE 2 – ADD OPTION 2 OF DEVICE IN A TO46 METAL CAN
PAGE 3, PARAGRAPH 3.8 – ADD FIGURES 6 & 7, BURN-IN CIRCUITS
PAGE 3, PARAGRAPH 3.10.1 – ADD FIGURE 2, CASE OUTLINE
PAGE 3, PARAGRAPH 3.11.3 – CHANGE FIGURE 3 TO FIGURE 5, TOTAL DOSE BIAS CIRCUIT
PAGE 7, ADD TO46/3 LEAD CASE OUTLINE, FIGUE 2
PAGE 8, TERMINAL CONNECTIONS FOR CERPAC – CHANGE FIGURE FROM 2 TO 3 AND
ADDED TERMINAL CONNECTIONS FOR TO46, FIGURE 4
PAGE 9, TOTAL DOSE BIAS CIRCUIT – CHANGE FIGURE FROM 3 TO 5
PAGE 10, STATIC BURN-IN CIRCUIT FOR FLATPACK FROM 4 TO 6
PAGE 11 ADDED - ADD STATIC BURN-IN CIRCUIT FOR TO46
PAGES 12 AND 13 ADDED – WERE ORIGINALLY PAGES 10 AND 11
PAGE 12 – ALL RAD MIN, MAX LIMITS AMENDED.
PAGE 12, TABLE 2: ELECTRICAL CHARACTERISTICS (Postirradiation) TA = 25°C – CHANGED
VZ, Reverse Breakdown Voltage:
10K RAD to MIN 1.202, MAX 1.305 V; 20K RAD to MIN 1.202, MAX 1.315 V;
50K RAD to MIN 1.202, MAX 1.325 V; 100K RAD to MIN 1.202, MAX 1.340 V;
200K RAD to MIN 1.202, MAX 1.370 V
PAGE 8, FIGURE 4, TERMINAL CONNECTIONS FOR H PACKAGE TO46 / 3 LEAD METAL
CAN, UPDATED FIGURE.
07/08/09
REVISION RECORD AND DESCRIPTION CONTINUED ON NEXT PAGE.
CAUTION: ELECTROSTATIC DISCHARGE SENSITIVE PART
REVISION
INDEX
REVISION
INDEX
PAGE NO.
REVISION
PAGE NO.
REVISION
APPLICATION
1
C
ORIG
DSGN
ENGR
MFG
CM
QA
PROG
FUNCT
2
C
3
C
4
C
5
C
SIGNOFFS
6
C
7
C
DATE
8
C
9
C
10
C
11
C
12
C
13
C
LINEAR TECHNOLOGY CORPORATION
MILPITAS, CALIFORNIA
TITLE:
MICROCIRCUIT, LINEAR,
RH1034M-1.2 MICROPOWER
DUAL REFERENCE
SIZE
CAGE CODE DRAWING NUMBER REV
64155
05-08-5229
C
CONTRACT:
FOR OFFICIAL USE ONLY
LINEAR TECHNOLOGY CORPORATION
Page 1 of 13
SPEC NO. 05-08-5229 REV. C
1.0
SCOPE:
1.1
2.0
RH1034M-1.2, MICROPOWER DUAL REFERENCE
This specification defines the performance and test requirements for a microcircuit processed to a space
level manufacturing flow.
APPLICABLE DOCUMENTS:
2.1
Government Specifications and Standards: the following documents listed in the Department of Defense
Index of Specifications and Standards, of the issue in effect on the date of solicitation, form a part of this
specification to the extent specified herein.
SPECIFICATIONS:
2.2
3.0
MIL-PRF-38535
Integrated Circuits (Microcircuits) Manufacturing, General Specification for
MIL-STD-883
Test Method and Procedures for Microcircuits
MIL-STD-1835
Microcircuits Case Outlines
Order of Precedence: In the event of a conflict between the documents referenced herein and the contents
of this specification, the order of precedence shall be this specification, MIL-PRF-38535 and other
referenced specifications.
REQUIREMENTS:
3.1
General Description: This specification details the requirements for the RH1034M-1.2 REFERENCE
processed to space level manufacturing flow.
3.2
Part Number:
3.3
3.2.1 Option 1 – RH1034MW-1.2
(Glass Sealed Flatpack, 10 Leads)
3.2.2 Option 2 – RH1034MH-1.2
(TO46 Metal Can, 3 Leads)
Part Marking Includes:
a.
LTC Logo
b.
LTC Part Number (See Paragraph 3.2)
c.
Date Code
d.
Serial Number
e.
ESD Identifier per MIL-PRF-38535, Appendix A
LINEAR TECHNOLOGY CORPORATION
Page 2 of 13
SPEC NO. 05-08-5229 REV. C
3.4
The Absolute Maximum Ratings:
(Note1)
. . . . .
Operating Current
.
. . . . .
Forward Current
.
Operating Temperature Range
. .
Storage Temperature Range
Lead Temperature (Soldering, 10 sec)
RH1034M-1.2, MICROPOWER DUAL REFERENCE
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
20mA
20mA
-55°C to +125°C
-65°C to +150°C
. . .
+300°C
3.5
Electrostatic discharge sensitivity, ESDS, shall be Class 1.
3.6
Electrical Performance Characteristics: The electrical performance characteristics shall be as specified in
Table I and Table II.
3.7
Electrical Test Requirements: Screening requirements shall be in accordance with 4.1 herein,
MIL-STD-883, Method 5004, and as specified in Table IV herein.
3.8
Burn-In Requirement: Burn-in circuit is specified in Figure 6 and 7.
3.9
Delta Limit Requirement: Delta limit parameters are specified in Table III herein, are calculated after
each burn-in, and the delta rejects are included in the PDA calculation.
3.10
Design, Construction, and Physical Dimensions: Detail design, construction, physical dimensions, and
electrical requirements shall be specified herein.
3.10.1 Mechanical / Packaging Requirements: Case outlines and dimensions are in accordance with
Figure 1.
3.10.2 Terminal Connections: The terminal connections shall be as specified in Figure 3 and 4.
3.10.3 Lead Material and Finish: The lead material and finish for Option 1 shall be Alloy 42 for
Flatpack with lead finish hot solder dip (Finish litter A) in accordance with MIL-PRF-38535.
The lead material and finish for Option 2 shall be gold plated Kovar.
3.11
Radiation Hardness Assurance (RHA):
3.11.1 The manufacturer shall perform a lot sample test as an internal process monitor for total dose
radiation tolerance. The sample test is performed with MIL-STD-883 TM1019 Condition A as a
guideline.
3.11.2 For guaranteed radiation performance to MIL-STD-883, Method 1019, total dose irradiation, the
manufacturer will provide certified RAD testing and report through an independent test
laboratory when required as a customer purchase order line item.
3.11.3 Total dose bias circuit is specified in Figure 5.
3.12
Wafer Lot Acceptance: Wafer lot acceptance shall be in accordance with MIL-PRF-38535, Appendix A,
except for the following: Topside glassivation thickness shall be a minimum of 4KÅ.
3.13
Wafer Lot Acceptance Report: SEM is performed per MIL-STD-883, Method 2018 and copies of SEM
photographs shall be supplied with the Wafer Lot Acceptance Report as part of a Space Data Pack when
specified as a customer purchase order line item.
LINEAR TECHNOLOGY CORPORATION
Page 3 of 13
SPEC NO. 05-08-5229 REV. C
4.0
RH1034M-1.2, MICROPOWER DUAL REFERENCE
VERIFICATION (QUALITY ASSURANCE PROVISIONS)
4.1
Quality Assurance Provisions: Quality Assurance provisions shall be in accordance with MIL-PRF38535. Linear Technology is a QML certified company and all Rad Hard candidates are assembled on
qualified Class S manufacturing lines.
4.2
Sampling and Inspection: Sampling and Inspection shall be in accordance with MIL-STD-883, Method
5005 with QML allowed and TRB approved deviations in conjunction with paragraphs 3.1.1, 3.2.1, and
3.4 of the test method.
4.3
Screening: Screening requirements shall be in accordance with MIL-STD-883, Method 5004 with QML
allowed and TRB approved deviations in conjunction with paragraphs 3.1, 3.1.1, and 3.4 of the test
method. Electrical testing shall be as specified in Table IV herein.
4.3.1
4.4
Analysis of catastrophic (open/short) failures from burn-in will be conducted only when a lot fails
the burn-in or re-burn-in PDA requirements.
Quality Conformance Inspection: Quality conformance inspection shall be in accordance with 4.2 and 4.3
herein and as follows:
4.4.1
Group A Inspection: Group A inspection shall be performed in accordance with 4.1 herein, per
MIL-STD-883, Method 5005, and specified in Table IV herein.
4.4.2
Group B Inspection: When purchased, a full Group B is performed on an inspection lot. As a
minimum, Subgroup B2 (Resistance to Solvents / Mark Permanency) and Subgroup B3
(Solderability) are performed prior to the first shipment from any inspection lot and Attributes
provided when a Full Space Data Pack is ordered. Subgroup B5 (Operating Life) is performed on
each wafer lot. This subgroup may or may not be from devices built in the same package style as
the current inspection lot. Attributes and variables data for this subgroup will be provided upon
request at no charge.
4.4.2.1
Group B, Subgroup 2c = 10%
Group B, Subgroup 3 = 10%
Group B, Subgroup 5 = *5%
(*per wafer or inspection lot
whichever is the larger quantity)
Group B, Subgroup 4 = 5%
Group B, subgroup 6 = 15%
4.4.2.2 All footnotes pertaining to Table IIa in MIL-STD-883, Method 5005 apply. The quantity
(accept number) of all other subgroups are per MIL-STD-883, Method 5005, Table IIa.
4.4.3
Group D Inspection: When purchased, a full Group D is performed on an inspection lot. As a
minimum, periodic full Group D sampling is performed on each package family for each
assembly location every 26 weeks. A generic Group D Summary is provided when a full Space
Data Pack is ordered.
4.4.3.1
Group D, Subgroups 3, 4 and 5 = 15% each (Sample Size Series).
4.4.3.2
All footnotes pertaining to Table IV in MIL-STD-883, Method 5005 apply. The
quantity (accept number) or sample number and accept number of all other subgroups
are per MIL-STD-883, Method 5005, Table IV.
LINEAR TECHNOLOGY CORPORATION
Page 4 of 13
SPEC NO. 05-08-5229 REV. C
4.5
4.6
RH1034M-1.2, MICROPOWER DUAL REFERENCE
Source Inspection:
4.5.1
The manufacturer will coordinate Source Inspection at wafer lot acceptance and pre-seal internal
visual.
4.5.2
The procuring activity has the right to perform source inspection at the supplier’s facility prior to
shipment for each lot of deliverables when specified as a customer purchase order line item. This
may include wafer lot acceptance and final data review.
Deliverable Data: Deliverable data that will ship with devices when a Space Data Pack is ordered:
4.6.1
Lot Serial Number Sheets identifying all devices accepted through final inspection by serial
number.
4.6.2
100% attributes (completed lot specific traveler; includes Group A Summary)
4.6.3
Burn-In Variables Data and Deltas (if applicable)
4.6.4
Group B2, B3, and B5 Attributes (Variables data, if performed on lot shipping)
4.6.5
Generic Group D data (4.4.3 herein)
4.6.6
SEM photographs (3.13 herein)
4.6.7
Wafer Lot Acceptance Report (3.13 herein)
4.6.8
X-Ray Negatives and Radiographic Report
4.6.9
A copy of outside test laboratory radiation report if ordered
4.6.10 Certificate of Conformance certifying that the devices meet all the requirements of this
specification and have successfully completed the mandatory tests and inspections herein.
Note: Items 4.6.1 and 4.6.10 will be delivered as a minimum, with each shipment. This is noted
on the Purchase Order Review Form as “No Charge Data”.
5.0
Packaging Requirements: Packaging shall be in accordance with Appendix A of MIL-PRF-38535. All devices
shall be packaged in conductive material or packaged in anti-static material with an external conductive field
shielding barrier.
LINEAR TECHNOLOGY CORPORATION
Page 5 of 13
SPEC NO. 05-08-5229 REV. C
RH1034M-1.2, MICROPOWER DUAL REFERENCE
(W10) GLASS SEALED FLATPACK / 10LEADS CASE OUTLINE
θja = +170°C/W
θjc = +40°C/W
FIGURE 1
LINEAR TECHNOLOGY CORPORATION
Page 6 of 13
SPEC NO. 05-08-5229 REV. C
RH1034M-1.2, MICROPOWER DUAL REFERENCE
(H) TO46 / 3 LEADS CASE OUTLINE
θja = +440°C/W
θjc = +80°C/W
Tj Max = +150°C
FIGURE 2
LINEAR TECHNOLOGY CORPORATION
Page 7 of 13
SPEC NO. 05-08-5229 REV. C
RH1034M-1.2, MICROPOWER DUAL REFERENCE
TERMINAL CONNECTIONS
FIGURE 3
FIGURE 4
LINEAR TECHNOLOGY CORPORATION
Page 8 of 13
SPEC NO. 05-08-5229 REV. C
RH1034M-1.2, MICROPOWER DUAL REFERENCE
TOTAL DOSE BIAS CIRCUIT
FIGURE 5
LINEAR TECHNOLOGY CORPORATION
Page 9 of 13
SPEC NO. 05-08-5229 REV. C
RH1034M-1.2, MICROPOWER DUAL REFERENCE
STATIC BURN-IN CIRCUIT
OPTION 1, GLASS SEALED FLATPACK / 10 LEAD
FIGURE 6
LINEAR TECHNOLOGY CORPORATION
Page 10 of 13
SPEC NO. 05-08-5229 REV. C
RH1034M-1.2, MICROPOWER DUAL REFERENCE
STATIC BURN-IN CIRCUIT
OPTION 2, TO46 METAL CAN / 3 LEAD
FIGURE 7
LINEAR TECHNOLOGY CORPORATION
Page 11 of 13
SPEC NO. 05-08-5229 REV. C
RH1034M-1.2, MICROPOWER DUAL REFERENCE
TABLE I: ELECTRICAL CHARACTERISTICS (PRE-IRRADIATION) NOTE 3
TABLE II: ELECTRICAL CHARACTERISTICS (POST-IRRADIATION) NOTE 3
TA = 25°C
LINEAR TECHNOLOGY CORPORATION
Page 12 of 13
SPEC NO. 05-08-5229 REV. C
RH1034M-1.2, MICROPOWER DUAL REFERENCE
TABLE III: POST BURN-IN ENDPOINTS AND DELTA LIMIT REQUIREMENTS
TA = 25°C
TABLE IV: ELECTRICAL TEST REQUIREMENTS
MIL-STD-883 TEST REQUIREMENTS
SUBGROUP
FINAL ELECTRICAL TEST REQUIREMENTS (METHOD 5004)
1*, 2, 3
GROUP A TEST REQUIREMENTS (METHOD 5005)
1*, 2, 3
GROUP B AND D FOR CLASS S ENDPOINT ELECTRICAL PARAMETERS (METHOD 5005)
1, 2, 3
*PDA APPLIES TO SUBGROUP 1.
PDA TEST NOTE: The PDA is specified as 5% based on failures from Group A, Subgroup 1, tests after cool down as the final
electrical test in accordance with method 5004 of MIL-STD-883. The verified failures of Group A, Subgroup 1 and delta rejects after
burn-in divided by the total number of devices submitted for burn-in in that lot shall be used to determine the percent for the lot.
LINEAR TECHNOLOGY CORPORATION
Page 13 of 13