Download PDF

5
LOAD/CHG
BAT-
BAT+
TS
4
CONN_1
GAS GAUGE
1
2
3
4
5
6
2
1
CONN_2
GAS GAUGE
1
GPIO1_GG
2
GPIO2_GG
3
GPIO3_GG
4
GPIO4_GG
BCM_I2C_SDA 5
BCM_I2C_SCL 6
1x6
HMTSW-106-07-G-S-230-005
D
3
1x6
HMTSW-106-07-G-S-230
D
SUB-MODULE CONNECTORS
C
R5
1.8M
1/16W
LOAD/CHG IS INTENTIONALLY
SHORTED TO BAT+
LOAD/CHG
C
BAT+
U1
1
2
3
4
TS
C4
.47uF
10V
C2
0.1uF
10V
C3
0.1uF
10V
BIN
REG25
REGIN
BAT
BCM_I2C_SDA 10
BCM_I2C_SCL 11
VSS
PWPD
12
GPIO1_GG
6
13
BQ27410DRZ-G1
C1
0.1uF
SRP
SRN
5
R6
10K
1/10W
SDA GPOUT
SCL
7
8
BAT-
VCC
10V
R4
0.01
1/4W
C1 should be as close as possible to the IC. IC connection to sense resistor must be of Kelvin connection type.
B
B
BQ27410-G1 Gas Gauge Sub-Module
A
A
Approval
LB1
REV A
5
4
3
Designer
Antonio Fadhel
Drawn By
Antonio Fadhel
Layout
Dawn Ritz
Title
Date
SMP-BQ27410G1-MVK
Rev A
Size B
EDGE No 6527570
Date Monday, September 26, 2011
2
Sheet 1 of 1
1