typ TA45-3PA

TA45-3PA
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Circuit Breaker for Equipment thermal, 3 pole, Push button actuation, with auxiliary contact
Description
-Thermal circuit breaker
-2 pole thermal overload protection
-Positively trip-free release
-High configurability
-Snap-in or flange mounted
-Quick connect terminal 6.3 x 0.8 mm or screw clamp terminal M3.5 x
6 mm (lineside P1, P2)
Approvals
Applications
-Power tools
-Industrial appliances
-Power supplies
Weblinks
pdf-datasheet, html-datasheet, General Product Information,
Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product, Product News
-Approval Reference Type: TA45
-IEC Standard: IEC 60934
-GB Standard: GB 17701
Technical Data
Rated Voltage AC
Rated current range AC
Degree of Protection
Dielectric Strength
Insulation resistance
Endurance typical
␣
400 V
0.05 - 12 A
from front side IP 40 acc. to IEC 60529
4 kVAC
500 VDC > 100 MΩ
mechanical: 50'000 switching cycles
AC: 1 x Ir:
50'000 switching cycles
Dimension
Snap-in type and quick connect terminal with auxiliary contact
Overload
AC: min. 40 trips
@ 6 x Ir
-10 °C to 55 °C
± 0.75 mm @ 10 - 60 Hzacc. to IEC
60068-2-6, test Tc10 G @ 60 - 500
Hzacc. to IEC 60068-2-6, test Tc
30 G / 18 msacc. to IEC 60068-2-27,
test Ea
Thermal Pushbutton 60 - 65 g
Ambient temperature
Vibration Resistance
Shock Resistance
Tripping Type
Actuation type
Weight
Snap-in type and screw clamp terminal with auxiliary contact
45.5
59
50
10.8
10
39
23.7
26.9
34.7
34
63
5
18.5
6
6
25
9
9
43.6
11
7
12
9
10.8
5.3 11.6 7.6 7.5 8.4
A)
A) Quick connect terminal, IEC 61210, A6.3-0.8 mm
11
10
11
12
7.5
10
10.6
7
5.3
B)
10.8
11
33
B) Screw type M3, 5x6 (Philips Form H), maximum torque 1 Nm
Circuit Breakers
1
TA45-3PA
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Flange type and screw clamp terminal with auxiliary contact
Flange type and quick connect terminal with auxiliary contact
23.7
10
32.2
10.8
44.2
63
43.3
39.3
4
13
6
6
34
25
74
50
9
9
43.6
12
9
10.6
7
10.8
5.3 11.6 7.6 7.5 8.4
A)
10
11
12
7.5
11
10
7
11
B)
5.3
10.8
33
Cut-out and pin-out
Cut-out snap-in type
Cut-out flange type / Installation from rear
4.
44,5...45,0
44,5...45,0
44,7...45,2
44,7...45,2
44,8...45,3
44,9...45,4
45,0...45,5
+0.2
1.0
1.5
2.0
2.5
3.0
4.0
5.0
50.5 –0.0
b
60
a (1.0 – 5.0)
33.2 – 0.0
b
a
2
B) Screw type M3, 5x6 (Philips Form H), maximum torque 1 Nm
+0.2
A) Quick connect terminal, IEC 61210, A6.3-0.8 mm
1)
+0.2
25.2 –0.0
2)
1) Assemble
2) edge must be sharp
Pin-out
4.
2
Cut-out flange type/ Installation from rear with AZZ05 cover
P2
P1
7
+0.3
52.5 –0.0
60
b
U-Relais
*)
a
10
11
c
4
+0.3
27.5 –0.0
6
12
3
9
5
*) Auxiliary contact / 3 pole
2
Circuit Breakers
TA45-3PA
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Diagrams
Without thermal overload protection, 2pole thermal overload protection,
Auxiliary contact
Auxiliary contact
P2
P1
6
5
7 11 10
9
12
P2
P1
4
3
2pole thermal overload protection,
Auxiliary contact, Shunt terminal
7 11 10
6
9 12
P2
P1
4
3
7 11 10
5 9 12
Time-Current-Curves
[ min ] [ sec ]
10'000
[ min ] [ sec ]
10'000
60
30
20
10
Type
TA45
Type
Rated current
In <3 A
Rated current
2`000
Ambient temp.
1`000
60
3 pole switch
2 pole protected
30
+23ºC
20
10
500
5
2`000
Ambient temp.
1`000
+23ºC
500
200
100
Time in Seconds
100
Time in Seconds
3 A > In <12 A
3 pole switch
2 pole protected
5
200
1
TA45
50
20
10
1
50
20
10
5
5
2
2
1
1
0,5
0,5
0,3
0,3
0,2
0,2
0,1
0,1
1,05 1,32
2
3
4
5
8
10
1,05 1,32
Multiple of Rated Current In
Multiple of Rated Current In
Reference Temperature +23°
Reference Temperature +23°
2
3
4
5
8
10
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient temperature [°C]
Correction factor
-10
0.89
-5
0.91
0
0.92
+23
1.00
+30
1.03
+40
1.08
+55
1.16
Example: Rated current = 5 A; Environmental temperature = 40 °C; --> Correction factor =
1.08; Resulting current = 5.5 A --> Fount to next higher rated current: 6 A
Auxiliary contact (changeover)
Rated Voltage
28 VDC
60 VDC
240 VAC
Rated current
max. 10 A resistive load
max. 2 A resistive load
max. 2 A cos φ 0.7
Circuit Breakers
3
TA45-3PA
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Config. Code
TA45|-|AK2|W|F|120|A2|-|AZM11|
The characters are placeholders for the correspondingly keys of selections from the key tables.
TA45|-| AK2 |W|F|120|A2|-|AZM11| = Basic function
Legend
Configuration
key
AMS
3-pole, push button, 2p overload protection, auxiliary contact, flat connection, flange type, push button gasket IP65
AMW
3-pole, push button, 2p overload protection, auxiliary contact and shunt
terminal, flat connection, flange type, push button gasket IP65
AMX
3-pole, push button, auxiliary contact, screw connection, flange type, push
button gasket IP40
ARK
3-pole, push button, 2p overload protection, auxiliary contact, screw connection, flange type, push button gasket IP40
ARN
3-pole, push button, 2p overload protection, auxiliary contact and shunt
terminal, screw connection, flange type, push button gasket IP40
ARP
3-pole, push button, auxiliary contact, screw connection, flange type, push
button gasket IP65
ARS
3-pole, push button, 2p overload protection, auxiliary contact, screw connection, flange type, push button gasket IP65
ARW
3-pole, push button, 2p overload protection, auxiliary contact and shunt
terminal, screw connection, flange type, push button gasket IP65
ARX
3-pole, push button, auxiliary contact, flat connection, snap-in type, push
button gasket IP40
AVK
3-pole, push button, 2p overload protection, auxiliary contact, flat connection, snap-in type, push button gasket IP40
AVN
3-pole, push button, 2p overload protection, auxiliary contact and shunt
terminal, flat connection, snap-in type, push button gasket IP40
AVP
3-pole, push button, auxiliary contact, flat connection, snap-in type, push
button gasket IP65
AVS
0
3-pole, push button, auxiliary contact, flat connection, flange type, push
button gasket IP65
black printed
white printed
ON
AMP
OFF
3-pole, push button, 2p overload protection, auxiliary contact and shunt
terminal, flat connection, flange type, push button gasket IP40
white printed
ON
AMN
F
H
OFF
3-pole, push button, 2p overload protection, auxiliary contact, flat connection, flange type, push button gasket IP40
embossed
I
AMK
K
L
0
3-pole, push button, auxiliary contact, flat connection, flange type, push
button gasket IP40
I
Configuration
key
M
0
black printed
I
white printed
I
P
0
black printed
I
R
0
white printed
ON
I
0
OFF
S
ON
I
0
OFF
Basic function
T
black printed
TA45|-|AK2|W|F| 120 |A2|-|AZM11| = Rated current
Rated current
Configuration
key
without thermal overload protection / temporarily without VDE approval
C00
0.05 A
Z05
0.1 A
J01
0.2 A
J02
0.3 A
J03
0.4 A
J04
0.5 A
J05
0.6 A
J06
0.7 A
J07
0.8 A
J08
0.9 A
J09
1.0 A
J10
1.1 A
J11
1.2 A
J12
1.3 A
J13
1.4 A
J14
1.5 A
J15
Configuration
key
1.6 A
J16
1.7 A
J17
Front Black: Green/Red
T
1.8 A
J18
Front Yellow: Green/Red
U
Other rated currents on request
Front Grey: Green/Red
V
3-pole, push button, 2p overload protection, auxiliary contact, flat connection, snap-in type, push button gasket IP65
AVW
3-pole, push button, 2p overload protection, auxiliary contact and shunt
terminal, flat connection, snap-in type, push button gasket IP65
AVX
3-pole, push button, auxiliary contact, screw connection, snap-in type, push
button gasket IP40
AYK
3-pole, push button, 2p overload protection, auxiliary contact, screw connection, snap-in type, push button gasket IP40
AYN
3-pole, push button, 2p overload protection, auxiliary contact and shunt
terminal, screw connection, snap-in type, push button gasket IP40
AYP
3-pole, push button, auxiliary contact, screw connection, snap-in type, push
button gasket IP65
AYS
3-pole, push button, 2p overload protection, auxiliary contact, screw connection, snap-in type, push button gasket IP65
AYW
3-pole, push button, 2p overload protection, auxiliary contact and shunt
terminal, screw connection, snap-in type, push button gasket IP65
AYX
TA45|-|AK2| W |F|120|A2|-|AZM11| = Actuator colour
Actuator colour
TA45|-|AK2|W| F |120|A2|-|AZM11| = Legend
4
Circuit Breakers
* The approved current range is 0.05 to 12 A. We recommend to limit the range to
max. 8 A at AC 400 V.
For the current range 9 to 12 A the voltage should be limited to AC 240 V.
TA45-3PA
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Rated current
Configuration
key
Rated current
Configuration
key
1.9 A
J19
12.0 A*
120
2.0 A
J20
Other rated currents on request
2.1 A
J21
2.2 A
J22
2.3 A
J23
2.5 A
J25
* The approved current range is 0.05 to 12 A. We recommend to limit the range to
max. 8 A at AC 400 V.
For the current range 9 to 12 A the voltage should be limited to AC 240 V.
TA45|-|AK2|W|F|120| A2 |-|AZM11| = Release / lock-out latch
2.8 A
J28
3.0 A
030
3.5 A
035
4.0 A
040
4.5 A
045
Remote trip release, rated voltage 400 V AC
A1
5.0 A
050
whithout release / lock-out latch
C0
060
Undervoltage release with additional contact, rated voltage 400 V AC
E1
6.5 A
065
Undervoltage release, rated voltage 400 V AC
U1
7.0 A
070
Undervoltage release with 2 additional contacts, rated voltage 400 V AC
Z1
7.5 A
075
8.0 A
080
9.0 A*
090
10.0 A*
100
11.0 A*
110
6.0 A
Other rated currents on request
Release / lock-out latch
Configuration
key
TA45|-|AK2|W|F|120|A2|-| AZM11 | = Accessories
Factory mounted accessories
Configuration
key
Without cover
For subsequent fitting accessories see:
* The approved current range is 0.05 to 12 A. We recommend to limit the range to
max. 8 A at AC 400 V.
For the current range 9 to 12 A the voltage should be limited to AC 240 V.
http://www.schurter.ch/pdf/english/typ_TA45-ACC.pdf
Variants
Addition
Thermal
overload protection
connection
type
Mounting
IP Protection
Class Front
Side
Actuator
colour
Legend
Rated current
Accessories
Config. Code
Order Number
2-pole
Auxiliary
contact
Quick connect
terminal
Snap-in type
IP40
Front Black:
Green/Red
black printed
0.3 A
Without cover
TA45-AVNTMJ03C0
4430.3332
2-pole
Auxiliary
contact
Quick connect
terminal
Snap-in type
IP40
Front Black:
Green/Red
black printed
2.5 A
Without cover
TA45-AVNTMJ25C0
4430.3333
Availability for all products can be searched real-time:http://www.schurter.com/Stock-Check/Stock-Check-SCHURTER
Packaging Unit 1 Pcs Accessories
Description
TA45-ACC
Accessories to TA45
06.06.2016
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Circuit Breakers
5