typ TA45-3P

TA45-3P
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Circuit Breaker for Equipment thermal, 3 pole, Push button actuation
Description
-Thermal circuit breaker
-2 pole thermal overload protection
-Positively trip-free release
-High configurability
-Snap-in or flange mounted
-Quick connect terminal 6.3 x 0.8 mm or screw clamp terminal M3.5 x
6 mm (lineside P1, P2)
Approvals
Applications
-Power tools
-Industrial appliances
-Power supplies
Weblinks
pdf-datasheet, html-datasheet, General Product Information,
Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product, Product News
-Approval Reference Type: TA45
-IEC Standard: IEC 60934
-GB Standard: GB 17701
Technical Data
Rated Voltage AC
Rated current range AC
Degree of Protection
Dielectric Strength
Insulation resistance
Endurance typical
␣
400 V
0.05 - 12 A
from front side IP 40 acc. to IEC 60529
4 kVAC
500 VDC > 100 MΩ
mechanical: 50'000 switching cycles
AC: 1 x Ir:
50'000 switching cycles
Dimension
Snap-in type and quick connect terminal
Overload
AC: min. 40 trips
@ 6 x Ir
-10 °C to 55 °C
± 0.75 mm @ 10 - 60 Hzacc. to IEC
60068-2-6, test Tc10 G @ 60 - 500
Hzacc. to IEC 60068-2-6, test Tc
30 G / 18 msacc. to IEC 60068-2-27,
test Ea
Thermal Pushbutton 50 - 55 g
Ambient temperature
Vibration Resistance
Shock Resistance
Tripping Type
Actuation type
Weight
Snap-in type and screw clamp terminal
45.5
59
50
10.8
10
39
23.7
26.9
34.7
34
63
5
18.5
6
6
25
9
9
43.6
11
7
12
9
10.8
5.3 11.6 7.6 7.5 8.4
A)
A) Quick connect terminal, IEC 61210, A6.3-0.8 mm
11
10
11
12
7.5
10
10.6
7
5.3
B)
10.8
11
33
B) Screw type M3, 5x6 (Philips Form H), maximum torque 1 Nm
Circuit Breakers
1
TA45-3P
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Flange type and screw clamp terminal
Flange type and quick connect terminal
23.7
10
32.2
10.8
44.2
63
43.3
39.3
4
13
6
6
34
25
74
50
9
9
43.6
12
9
10.6
7
10.8
5.3 11.6 7.6 7.5 8.4
A)
10
11
12
7.5
11
10
7
11
B)
5.3
10.8
33
Cut-out and pin-out
Cut-out snap-in type
Cut-out flange type / Installation from rear
4.
44,5...45,0
44,5...45,0
44,7...45,2
44,7...45,2
44,8...45,3
44,9...45,4
45,0...45,5
+0.2
1.0
1.5
2.0
2.5
3.0
4.0
5.0
50.5 –0.0
b
60
a (1.0 – 5.0)
33.2 – 0.0
b
a
2
B) Screw type M3, 5x6 (Philips Form H), maximum torque 1 Nm
+0.2
A) Quick connect terminal, IEC 61210, A6.3-0.8 mm
1)
+0.2
25.2 –0.0
2)
1) Assemble
2) edge must be sharp
Pin-out
4.
2
Cut-out flange type/ Installation from rear with AZZ05 cover
P2
P1
7
+0.3
52.5 –0.0
60
b
U-Relais
*)
a
10
11
c
4
+0.3
27.5 –0.0
6
12
3
9
5
*) Auxiliary contact / 3 pole
2
Circuit Breakers
TA45-3P
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Diagrams
Without thermal overload protection
P2
P1
6
5
2 pole thermal overload protection
P2
7
P1
3
4
9
2 pole thermal overload protection,
Shunt terminal
7
P2
P1
4
3
9
6
7
5
9
Time-Current-Curves
[ min ] [ sec ]
10'000
[ min ] [ sec ]
10'000
60
30
20
Type
TA45
Type
Rated current
In <3 A
Rated current
2`000
Ambient temp.
1`000
10
60
3 pole switch
2 pole protected
30
+23ºC
20
10
500
5
2`000
Ambient temp.
1`000
+23ºC
500
200
100
100
Time in Seconds
Time in Seconds
3 A > In <12 A
3 pole switch
2 pole protected
5
200
1
TA45
50
20
10
1
50
20
10
5
5
2
2
1
1
0,5
0,5
0,3
0,3
0,2
0,2
0,1
0,1
1,05 1,32
2
3
4
5
8
10
1,05 1,32
Multiple of Rated Current In
Multiple of Rated Current In
Reference Temperature +23°
Reference Temperature +23°
2
3
4
5
8
10
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient temperature [°C]
Correction factor
-10
0.89
-5
0.91
0
0.92
+23
1.00
+30
1.03
+40
1.08
+55
1.16
Example: Rated current = 5 A; Environmental temperature = 40 °C; --> Correction factor =
1.08; Resulting current = 5.5 A --> Fount to next higher rated current: 6 A
Config. Code
TA45|-|AK2|W|F|120|A2|-|AZM11|
The characters are placeholders for the correspondingly keys of selections from the key tables.
TA45|-| AK2 |W|F|120|A2|-|AZM11| = Basic function
Circuit Breakers
3
TA45-3P
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
3-pole, push button, 2p overload protection, shunt terminal, flat connection,
flange type, push button gasket IP40
AKP
3-pole, push button, flat connection, flange type, push button gasket IP65
AKS
3-pole, push button, 2pole overload protection, flat connection, flange type,
push button gasket IP65
AKW
3-pole, push button, 2p overload protection, shunt terminal, flat connection,
flange type, push button gasket IP65
AKX
3-pole, push button, screw connection, flange type, push button gasket
IP40
ANK
3-pole, push button, 2pole overload protection, screw connection, flange
type, push button gasket IP40
ANN
3-pole, push button, 2p overload protection, shunt terminal, screw connection, flange type, push button gasket IP40
ANP
3-pole, push button, screw connection, flange type, push button gasket
IP65
ANS
3-pole, push button, 2pole overload protection, screw connection, flange
type, push button gasket IP65
ANW
3-pole, push button, 2p overload protection, shunt terminal, screw connection, flange type, push button gasket IP65
ANX
3-pole, push button, flat connection, snap-in type, push button gasket IP40
ATK
3-pole, push button, 2pole overload protection, flat connection, snap-in
type, push button gasket IP40
ATN
3-pole, push button, 2p overload protection, shunt terminal, flat connection,
snap-in type, push button gasket IP40
ATP
black printed
white printed
ON
AKN
OFF
3-pole, push button, 2pole overload protection, flat connection, flange type,
push button gasket IP40
I
AKK
Configuration
key
K
L
0
3-pole, push button, flat connection, flange type, push button gasket IP40
Legend
black printed
I
Configuration
key
M
0
Basic function
white printed
I
P
0
black printed
I
R
0
ON
I
0
OFF
white printed
S
ON
I
0
OFF
T
black printed
TA45|-|AK2|W|F| 120 |A2|-|AZM11| = Rated current
Rated current
Configuration
key
without thermal overload protection / temporarily without VDE approval
C00
Z05
3-pole, push button, flat connection, snap-in type, push button gasket IP65
ATS
0.05 A
3-pole, push button, 2pole overload protection, flat connection, snap-in
type, push button gasket IP65
ATW
0.1 A
J01
0.2 A
J02
3-pole, push button, 2p overload protection, shunt terminal, flat connection,
snap-in type, push button gasket IP65
ATX
0.3 A
J03
0.4 A
J04
0.5 A
J05
0.6 A
J06
0.7 A
J07
0.8 A
J08
0.9 A
J09
1.0 A
J10
1.1 A
J11
1.2 A
J12
1.3 A
J13
1.4 A
J14
1.5 A
J15
1.6 A
J16
Configuration
key
1.7 A
J17
1.8 A
J18
Front Black: Green/Red
T
1.9 A
J19
Front Yellow: Green/Red
U
2.0 A
J20
Front Grey: Green/Red
V
2.1 A
J21
2.2 A
J22
2.3 A
J23
2.5 A
J25
3-pole, push button, screw connection, snap-in type, push button gasket
IP40
AWK
3-pole, push button, 2pole overload protection, screw connection, snap-in
type, push button gasket IP40
AWN
3-pole, push button, 2p overload protection, shunt terminal, screw connection, snap-in type, push button gasket IP40
AWP
3-pole, push button, screw connection, snap-in type, push button gasket
IP65
AWS
3-pole, push button, 2pole overload protection, screw connection, snap-in
type, push button gasket IP65
AWW
3-pole, push button, 2p overload protection, shunt terminal, screw connection, snap-in type, push button gasket IP65
AWX
TA45|-|AK2| W |F|120|A2|-|AZM11| = Actuator colour
Actuator colour
TA45|-|AK2|W| F |120|A2|-|AZM11| = Legend
F
0
embossed
Configuration
key
I
Legend
4
ON
white printed
OFF
Circuit Breakers
2.8 A
J28
3.0 A
030
3.5 A
035
4.0 A
040
Other rated currents on request
H
* The approved current range is 0.05 to 12 A. We recommend to limit the range to
max. 8 A at AC 400 V.
For the current range 9 to 12 A the voltage should be limited to AC 240 V.
TA45-3P
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Rated current
Configuration
key
4.5 A
045
5.0 A
050
6.0 A
060
6.5 A
065
7.0 A
070
7.5 A
075
8.0 A
080
9.0 A*
090
10.0 A*
100
11.0 A*
110
12.0 A*
120
Other rated currents on request
TA45|-|AK2|W|F|120| A2 |-|AZM11| = Release / lock-out latch
Release / lock-out latch
Configuration
key
Remote trip release, rated voltage 400 V AC
A1
whithout release / lock-out latch
C0
Undervoltage release with additional contact, rated voltage 400 V AC
E1
Undervoltage release, rated voltage 400 V AC
U1
Undervoltage release with 2 additional contacts, rated voltage 400 V AC
Z1
TA45|-|AK2|W|F|120|A2|-| AZM11 | = Accessories
Factory mounted accessories
Configuration
key
Without cover
* The approved current range is 0.05 to 12 A. We recommend to limit the range to
max. 8 A at AC 400 V.
For the current range 9 to 12 A the voltage should be limited to AC 240 V.
For subsequent fitting accessories see:
http://www.schurter.ch/pdf/english/typ_TA45-ACC.pdf
Variants
Thermal
Addition
overload protection
connection
type
Mounting
IP Protection
Class Front
Side
Actuator
colour
Legend
Rated current
without
Quick connect
terminal
Flange type
IP40
Front Black:
Green/Red
embossed
2-pole
screw terminal Flange type
IP65
Front Black:
Green/Red
2-pole
Quick connect
terminal
IP65
Front Black:
Green/Red
Snap-in type
Accessories
Config. Code
Order Number
without thermal Without cover
overload protection / temporarily without VDE
approval
TA45-AKKTFC00C0
4430.0926
white printed
7.0 A
Without cover
TA45-ANWTL070C0
4430.3446
embossed
2.8 A
Without cover
TA45-ATWTFJ28C0
4430.3452
Availability for all products can be searched real-time:http://www.schurter.com/Stock-Check/Stock-Check-SCHURTER
Packaging Unit 1 Pcs Accessories
Description
TA45-ACC
Accessories to TA45
06.06.2016
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Circuit Breakers
5