TA45-3P Thermal (T- and TA-Line) www.schurter.com/PG17_18_19 Circuit Breaker for Equipment thermal, 3 pole, Push button actuation Description -Thermal circuit breaker -2 pole thermal overload protection -Positively trip-free release -High configurability -Snap-in or flange mounted -Quick connect terminal 6.3 x 0.8 mm or screw clamp terminal M3.5 x 6 mm (lineside P1, P2) Approvals Applications -Power tools -Industrial appliances -Power supplies Weblinks pdf-datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH, SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for product, Product News -Approval Reference Type: TA45 -IEC Standard: IEC 60934 -GB Standard: GB 17701 Technical Data Rated Voltage AC Rated current range AC Degree of Protection Dielectric Strength Insulation resistance Endurance typical ␣ 400 V 0.05 - 12 A from front side IP 40 acc. to IEC 60529 4 kVAC 500 VDC > 100 MΩ mechanical: 50'000 switching cycles AC: 1 x Ir: 50'000 switching cycles Dimension Snap-in type and quick connect terminal Overload AC: min. 40 trips @ 6 x Ir -10 °C to 55 °C ± 0.75 mm @ 10 - 60 Hzacc. to IEC 60068-2-6, test Tc10 G @ 60 - 500 Hzacc. to IEC 60068-2-6, test Tc 30 G / 18 msacc. to IEC 60068-2-27, test Ea Thermal Pushbutton 50 - 55 g Ambient temperature Vibration Resistance Shock Resistance Tripping Type Actuation type Weight Snap-in type and screw clamp terminal 45.5 59 50 10.8 10 39 23.7 26.9 34.7 34 63 5 18.5 6 6 25 9 9 43.6 11 7 12 9 10.8 5.3 11.6 7.6 7.5 8.4 A) A) Quick connect terminal, IEC 61210, A6.3-0.8 mm 11 10 11 12 7.5 10 10.6 7 5.3 B) 10.8 11 33 B) Screw type M3, 5x6 (Philips Form H), maximum torque 1 Nm Circuit Breakers 1 TA45-3P Thermal (T- and TA-Line) www.schurter.com/PG17_18_19 Flange type and screw clamp terminal Flange type and quick connect terminal 23.7 10 32.2 10.8 44.2 63 43.3 39.3 4 13 6 6 34 25 74 50 9 9 43.6 12 9 10.6 7 10.8 5.3 11.6 7.6 7.5 8.4 A) 10 11 12 7.5 11 10 7 11 B) 5.3 10.8 33 Cut-out and pin-out Cut-out snap-in type Cut-out flange type / Installation from rear 4. 44,5...45,0 44,5...45,0 44,7...45,2 44,7...45,2 44,8...45,3 44,9...45,4 45,0...45,5 +0.2 1.0 1.5 2.0 2.5 3.0 4.0 5.0 50.5 –0.0 b 60 a (1.0 – 5.0) 33.2 – 0.0 b a 2 B) Screw type M3, 5x6 (Philips Form H), maximum torque 1 Nm +0.2 A) Quick connect terminal, IEC 61210, A6.3-0.8 mm 1) +0.2 25.2 –0.0 2) 1) Assemble 2) edge must be sharp Pin-out 4. 2 Cut-out flange type/ Installation from rear with AZZ05 cover P2 P1 7 +0.3 52.5 –0.0 60 b U-Relais *) a 10 11 c 4 +0.3 27.5 –0.0 6 12 3 9 5 *) Auxiliary contact / 3 pole 2 Circuit Breakers TA45-3P Thermal (T- and TA-Line) www.schurter.com/PG17_18_19 Diagrams Without thermal overload protection P2 P1 6 5 2 pole thermal overload protection P2 7 P1 3 4 9 2 pole thermal overload protection, Shunt terminal 7 P2 P1 4 3 9 6 7 5 9 Time-Current-Curves [ min ] [ sec ] 10'000 [ min ] [ sec ] 10'000 60 30 20 Type TA45 Type Rated current In <3 A Rated current 2`000 Ambient temp. 1`000 10 60 3 pole switch 2 pole protected 30 +23ºC 20 10 500 5 2`000 Ambient temp. 1`000 +23ºC 500 200 100 100 Time in Seconds Time in Seconds 3 A > In <12 A 3 pole switch 2 pole protected 5 200 1 TA45 50 20 10 1 50 20 10 5 5 2 2 1 1 0,5 0,5 0,3 0,3 0,2 0,2 0,1 0,1 1,05 1,32 2 3 4 5 8 10 1,05 1,32 Multiple of Rated Current In Multiple of Rated Current In Reference Temperature +23° Reference Temperature +23° 2 3 4 5 8 10 Effect of ambient temperature The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from the table below: Ambient temperature [°C] Correction factor -10 0.89 -5 0.91 0 0.92 +23 1.00 +30 1.03 +40 1.08 +55 1.16 Example: Rated current = 5 A; Environmental temperature = 40 °C; --> Correction factor = 1.08; Resulting current = 5.5 A --> Fount to next higher rated current: 6 A Config. Code TA45|-|AK2|W|F|120|A2|-|AZM11| The characters are placeholders for the correspondingly keys of selections from the key tables. TA45|-| AK2 |W|F|120|A2|-|AZM11| = Basic function Circuit Breakers 3 TA45-3P Thermal (T- and TA-Line) www.schurter.com/PG17_18_19 3-pole, push button, 2p overload protection, shunt terminal, flat connection, flange type, push button gasket IP40 AKP 3-pole, push button, flat connection, flange type, push button gasket IP65 AKS 3-pole, push button, 2pole overload protection, flat connection, flange type, push button gasket IP65 AKW 3-pole, push button, 2p overload protection, shunt terminal, flat connection, flange type, push button gasket IP65 AKX 3-pole, push button, screw connection, flange type, push button gasket IP40 ANK 3-pole, push button, 2pole overload protection, screw connection, flange type, push button gasket IP40 ANN 3-pole, push button, 2p overload protection, shunt terminal, screw connection, flange type, push button gasket IP40 ANP 3-pole, push button, screw connection, flange type, push button gasket IP65 ANS 3-pole, push button, 2pole overload protection, screw connection, flange type, push button gasket IP65 ANW 3-pole, push button, 2p overload protection, shunt terminal, screw connection, flange type, push button gasket IP65 ANX 3-pole, push button, flat connection, snap-in type, push button gasket IP40 ATK 3-pole, push button, 2pole overload protection, flat connection, snap-in type, push button gasket IP40 ATN 3-pole, push button, 2p overload protection, shunt terminal, flat connection, snap-in type, push button gasket IP40 ATP black printed white printed ON AKN OFF 3-pole, push button, 2pole overload protection, flat connection, flange type, push button gasket IP40 I AKK Configuration key K L 0 3-pole, push button, flat connection, flange type, push button gasket IP40 Legend black printed I Configuration key M 0 Basic function white printed I P 0 black printed I R 0 ON I 0 OFF white printed S ON I 0 OFF T black printed TA45|-|AK2|W|F| 120 |A2|-|AZM11| = Rated current Rated current Configuration key without thermal overload protection / temporarily without VDE approval C00 Z05 3-pole, push button, flat connection, snap-in type, push button gasket IP65 ATS 0.05 A 3-pole, push button, 2pole overload protection, flat connection, snap-in type, push button gasket IP65 ATW 0.1 A J01 0.2 A J02 3-pole, push button, 2p overload protection, shunt terminal, flat connection, snap-in type, push button gasket IP65 ATX 0.3 A J03 0.4 A J04 0.5 A J05 0.6 A J06 0.7 A J07 0.8 A J08 0.9 A J09 1.0 A J10 1.1 A J11 1.2 A J12 1.3 A J13 1.4 A J14 1.5 A J15 1.6 A J16 Configuration key 1.7 A J17 1.8 A J18 Front Black: Green/Red T 1.9 A J19 Front Yellow: Green/Red U 2.0 A J20 Front Grey: Green/Red V 2.1 A J21 2.2 A J22 2.3 A J23 2.5 A J25 3-pole, push button, screw connection, snap-in type, push button gasket IP40 AWK 3-pole, push button, 2pole overload protection, screw connection, snap-in type, push button gasket IP40 AWN 3-pole, push button, 2p overload protection, shunt terminal, screw connection, snap-in type, push button gasket IP40 AWP 3-pole, push button, screw connection, snap-in type, push button gasket IP65 AWS 3-pole, push button, 2pole overload protection, screw connection, snap-in type, push button gasket IP65 AWW 3-pole, push button, 2p overload protection, shunt terminal, screw connection, snap-in type, push button gasket IP65 AWX TA45|-|AK2| W |F|120|A2|-|AZM11| = Actuator colour Actuator colour TA45|-|AK2|W| F |120|A2|-|AZM11| = Legend F 0 embossed Configuration key I Legend 4 ON white printed OFF Circuit Breakers 2.8 A J28 3.0 A 030 3.5 A 035 4.0 A 040 Other rated currents on request H * The approved current range is 0.05 to 12 A. We recommend to limit the range to max. 8 A at AC 400 V. For the current range 9 to 12 A the voltage should be limited to AC 240 V. TA45-3P Thermal (T- and TA-Line) www.schurter.com/PG17_18_19 Rated current Configuration key 4.5 A 045 5.0 A 050 6.0 A 060 6.5 A 065 7.0 A 070 7.5 A 075 8.0 A 080 9.0 A* 090 10.0 A* 100 11.0 A* 110 12.0 A* 120 Other rated currents on request TA45|-|AK2|W|F|120| A2 |-|AZM11| = Release / lock-out latch Release / lock-out latch Configuration key Remote trip release, rated voltage 400 V AC A1 whithout release / lock-out latch C0 Undervoltage release with additional contact, rated voltage 400 V AC E1 Undervoltage release, rated voltage 400 V AC U1 Undervoltage release with 2 additional contacts, rated voltage 400 V AC Z1 TA45|-|AK2|W|F|120|A2|-| AZM11 | = Accessories Factory mounted accessories Configuration key Without cover * The approved current range is 0.05 to 12 A. We recommend to limit the range to max. 8 A at AC 400 V. For the current range 9 to 12 A the voltage should be limited to AC 240 V. For subsequent fitting accessories see: http://www.schurter.ch/pdf/english/typ_TA45-ACC.pdf Variants Thermal Addition overload protection connection type Mounting IP Protection Class Front Side Actuator colour Legend Rated current without Quick connect terminal Flange type IP40 Front Black: Green/Red embossed 2-pole screw terminal Flange type IP65 Front Black: Green/Red 2-pole Quick connect terminal IP65 Front Black: Green/Red Snap-in type Accessories Config. Code Order Number without thermal Without cover overload protection / temporarily without VDE approval TA45-AKKTFC00C0 4430.0926 white printed 7.0 A Without cover TA45-ANWTL070C0 4430.3446 embossed 2.8 A Without cover TA45-ATWTFJ28C0 4430.3452 Availability for all products can be searched real-time:http://www.schurter.com/Stock-Check/Stock-Check-SCHURTER Packaging Unit 1 Pcs Accessories Description TA45-ACC Accessories to TA45 06.06.2016 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. Circuit Breakers 5