Derating Download

DERATING CURVE ( Current carrying capacity acc. IEC 60512-5-2 Test 5b)
iBridge Connector 8 Cont. with 250 mm stranded dicrete wire AWG22
Max. component temperature 125ºC
Current [A]
8.0
7.0
6.0
5.0
4.0
3.0
2.0
Base Curve [A]
1.0
Derating Curve [A]
Temperature [ ºC]
0.0
0
10
20
30
40
50
60
70
80
90
100
110
120
Base Curve [A]
7.15
6.66
6.21
5.80
5.37
4.85
4.25
3.57
2.84
2.07
0.74
Derating Curve [A]
5.72
5.33
4.97
4.64
4.30
3.88
3.40
2.86
2.27
1.66
0.59