DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b) IDC-Terminal for AWG24/7 - 26/7, D1.1 - D1.3 AWG24/7 Cable, Tmax = 150°C Current [A] 20,0 applicable to IDC terminal only 18,0 Base curve [A] Derating curve [A] 16,0 current rating of wiring/cabling according dedicated specification 14,0 12,0 10,0 8,0 6,0 4,0 2,0 Temperature [°C] 0,0 Base curve [A] Derating curve [A] 20 30 40 50 60 70 80 90 100 110 120 130 140 150 18,0 14,4 17,3 13,8 16,6 13,3 15,8 12,7 15,1 12,0 14,2 11,4 13,3 10,7 12,4 9,9 11,3 9,1 10,2 8,1 8,9 7,1 7,3 5,8 5,2 4,2 0,0 0,0 DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b) IDC-Terminal for AWG24/7 - 26/7, D1.1 - D1.3 AWG 26/7 Cable, Tmax = 150°C Current [A] 18,0 applicable to IDC terminal only 16,0 Base curve [A] Derating curve [A] 14,0 current rating of wiring/cabling according 12,0 dedicated specification 10,0 8,0 6,0 4,0 2,0 Temperature [°C] 0,0 Base curve [A] Derating curve [A] 20 30 40 50 60 70 80 90 100 110 120 130 140 150 15,9 12,7 15,3 12,2 14,7 11,7 14,0 11,2 13,3 10,7 12,6 10,1 11,9 9,5 11,0 8,8 10,1 8,1 9,1 7,3 7,9 6,4 6,6 5,2 4,7 3,8 0,0 0,0