DIN Connectors with Cables Attached XC6 Wider range of uses than normal DIN Connectors ■ Two types of Connectors, for flat cables and dis- crete wires. Select the type for your application. ■ Flat Cable Connectors (XC6D, XC6H) enable VME bus configurations (daisy chain) and backplane systems. ■ The Discrete-wire Press-fit Connectors (XC6V) have solderless contacts and use separated contact blocks to significantly reduce the number of harnesses. RoHS Compliant ■ Connectors Model XC6D XC6H XC6V Appearance Flat Cable Connectors with double rows Flat Cable Connectors with triple rows Discrete-wire Press-fit Connectors Page 5 2 3 ■ Ratings and Characteristics Item XC6D XC6H XC6V Rated current 1A 0.65 A 3 A max. Rated voltage 250 VAC 100 VAC 300 VAC Contact resistance 20 mΩ max. (at 20 mV, 100 mA max.) Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric strength 500 VAC Total insertion force 0.59 N per contact max. 300 VAC 650 VAC Removal force 0.15 N min. (with test gauge, t = 0.56 mm) Insertion durability 200 times Ambient operating temperature Operating: −55 to 105°C Remarks 1 minute, leakage current 1 mA max. (with no icing at low temperature) ■ Materials and Finish Item XC6D Housings Contacts Note: XC6V (See note.) Mating end Copper alloy/nickel base, 0.4-µm gold plating Terminal Strain Relief XC6H Fiber-glass reinforced PBT resin (UL94V-0)/gray Copper alloy/nickel base, 2.0-µm tin plating Fiber-glass reinforced PBT resin (UL94V-0)/gray --- This includes the Connector Housing and Single-row Contact Housing. ■ Applicable Wires Model Wire XC6D XC6H XY3A-640@ 1.27 mm-pitch flat cable XY3A-9605 0.847 mm-pitch flat cable AWG28 (strand wire) 64 strands AWG30 (strand wire) 96 strands UL2651 (standard cable) UL20028 (standard cable) UL20012 (folding cable) XC6V (See note.) • Size 1 AWG24 (uses UL1061) AWG26 (uses UL1007) • Size 2 AWG26/28 (uses UL1007) UL20028 (color-coded cable) Note: The size numbers are printed on the insulation barrel part of the contact. 1 XC6V Discrete-wire Press-fit DIN Connectors ■ Dimensions (unit: mm) Connector Housing XC6M-96 Two, 2.8 dia. Coding Key slot Single-row Contacts XC6W-3221 (Size 1 AWG24/26) XC6W-3222 (Size 2 AWG26/28) Contact No. Spare Contacts XC6W-0021 (Size 1, AWG24/26) XC6W-0022 (Size 2, AWG26/28) Dummy Board XC6T-32 Note: Dimensions are the same as those for the Single-row Contacts. Contact No. Note: This can be used as a replacement Connector in the event of erroneous connection. ■ Ordering Information Individual Models Name No. of contacts Applicable wire Combinations Model Connector Housing (See note.) --- XC6M-96 Single-row Contacts 32 AWG24/26 XC6W-3221 32 AWG26/28 XC6W-3222 Dummy Board --- --- XC6T-32 Spare Contacts --- AWG24/26 XC6W-0021 --- AWG26/28 XC6W-0022 Note: Three Single-row Contacts (32 contacts) can be inserted. No. of contacts 96 64 Applicable wire Model Model and quantity AWG24/26 XC6V-9621 XC6M-96 × 1 XC6W-3221 × 3 AWG26/28 XC6V-9622 XC6M-96 × 1 XC6W-3222 × 3 AWG24/26 XC6V-6421 XC6M-96 × 1 XC6W-3221 × 2 XC6T-32 × 1 AWG26/28 XC6V-6422 XC6M-96 × 1 XC6W-3222 × 2 XC6T-32 × 1 Note: 1. Accommodating model numbers are not printed on the Connectors. 2. For combinations other than the above especially when using different wires for each row, order the Connectors individually. DIN Connectors (Cable Connecting) XC6 5 ■ XC6V Accessories Contact Extraction Tool Wire Press-fit Tool Set XY2D-0003 XY2B-2105-N Used to remove contacts that were mistakenly connected to the socket housing. Model XY2D-0003 Procedure 1. Insert the lance holder of the tool into the lance hole in the housing. 2. When the hole is wide enough, remove the contact. 3. Insert a new Spare Contact. (Contact the product dealer for delivery details.) Model XY2B-2105-N This simple electric press-fit tool is designed for XC6V Discrete-wire DIN Connectors. Specifications Stroke 13 mm Motor speed 83/100 rpm (50/60 Hz) Feed pitch 2.54 mm Operation Foot switch Weight About 6 kg Rated voltage 0.5 A, 100 VAC (50/ 60 Hz) Fuse 1A Dimensions 120 × 200 × 225 mm (W × H × D) Note: See the Press-fit Tool User’s Manual for function and operating details. Applicable Connectors and Wires Applicable Cont Connector act No. Applicable wires UL file No. XC6V-9621 No. 1 UL1061 (Connector set) XC6W-3221 UL1007 (Single-row Contacts) XC6V-9622 No. 2 UL1007 (Connector set) XC6W-3222 (Single-row Contacts) Size [No. or Cross- Covering wires/diameter sectional diameter (mm)] area (mm) (mm) AWG24 [7/0.203] 0.21 1.10 dia. AWG26 [7/0.16] 0.13 1.30 dia. AWG26 [7/0.16] 0.13 1.30 dia. AWG28 [7/0.127] 0.09 1.20 dia. Note: Use only wires specified in the table above. 6 DIN Connectors (Cable Connecting) XC6