ALARM RELAYS RA100 - RA101 - RA102 - RA103 Desenganging frequency: RA100 - 15 Hz Desenganging frequency: RA101 - 54 Hz Desenganging frequency: RA102 - 15 Hz Desenganging frequency: RA103 - 54 Hz Supply: 24 V DC Current: 4 mA max. Operating temperature: 0°C to + 70°C 10 Wires output: RA100 - RA101 Terminals output: RA102 - RA103 Ø 25.4 6 3. 50.8 TERMINALS OUTPUT http://www.etrinet.com x Ø1 10.16 7 10.16 5.08 5.08 5.08 20.32 WIRES OUTPUT e-mail: [email protected] ETRI is a trade mark of ECOFIT, Non contractual document. Specifications are subject to change without prior notice. Pictures for information only. Edition N°2/0-Rev. 1 ALARM RELAYS RA104 - RA105 Desenganging frequency: RA104 - 25 Hz Desenganging frequency: RA105 - 15 Hz Supply: 24 V DC (19 V to 26 V) Current: 4 mA for "Running" - 15 mA for "Default" Operating temperature: 0°C to + 70°C 10 Contact: Switch off power: 3 W Max. voltage: 100 V Max. current: 0,25 A Contact resistance: 150 mΩ Ø 25.4 6 3. 50.8 WIRES OUTPUT http://www.etrinet.com e-mail: [email protected] ETRI is a trade mark of ECOFIT, Non contractual document. Specifications are subject to change without prior notice. Pictures for information only. Edition N°2/0-Rev. 1 ALARM RELAYS RA107 Desenganging frequency: 15 Hz Supply: 220 V - 50/60 Hz Operating temperature: 0°C to + 70°C Contact: Switch off power: 3 W Max. voltage: 100 V Max. current: 0,25 A Contact resistance: 150 mΩ A: 3 wires (AWG24) Red, White, Black Length 300 mm - Bore 6 mm B: 3 wires (AWG24) Green, Yellow, Violet Length 300 mm - Bore 6 mm A: 2 wires (AWG24) Brown Length 300 mm - Bore 6 mm 55 ± 0.2 http://www.etrinet.com 3 ± 0.5 40 ± 0.2 62 ± 0.2 55 ± 0.2 70 ± 0.2 40 ± 0.2 e-mail: [email protected] ETRI is a trade mark of ECOFIT, Non contractual document. Specifications are subject to change without prior notice. Pictures for information only. Edition N°2/0-Rev. 1