2Q 2015 Power Systems Announcement Highlights Thomas Prokop Consulting I/T Specialist There are 7.1 billion people on the planet 6 billion of them have access to mobile phones, only 3.5 billion of them use a toothbrush 2 © 2014, 2015 International Business Machines Corporation Security Breaches The average data breach in the US costs more than $11M Source: Ponemon Institute 2013 Cost of Cyber-Crime study A typical security attack goes unnoticed for nearly 8 months Source: https://www.mandiant.com/news/release/mandiant-releases-annual-threat-report-on-advanced-targetedattacks1/ 42% of security breaches are caused by configuration errors Source: IBM Security Services Cyber Security Intelligence Index, 7/2013 Lost or stolen credentials play a role in an estimated 76% of network breaches Source: http://www.verizonenterprise.com/resources/reports/rp_data-breach-investigations- report-2013_en_xg.pdf © 2014, 2015 International Business Machines Corporation Agenda Power E880 and E870 enhancements The New Power E880 Gen3 I/O Drawer enhancements New PCIe adapters and SRIOV Other info sprinkled in here and there © 2014, 2015 International Business Machines Corporation Power E870 & E880 servers Power E870 • • • • Power E880 Increased performance and scale Built-in PowerVM Enterprise Edition Enterprise RAS System Control Unit (2U) Built-in Active Memory Mirroring for Hypervisor More performance per-watt 8 PCIe adapter slots per node Up to 4 PCIe I/O drawers per Node Share resources in Power Enterprise Pool Medium Software tier PowerCare Services included 24x7 Warranty 8 to 80 cores @ 4.19 GHz 8 to 64 cores @ 4.0 GHz 256 to 8TB Memory 1 or 2 nodes (5U) per system • • • • • © 2014, 2015 International Business Machines Corporation 8 to 128 cores @ 4.35 GHz Up to 192 cores @ 4 GHz 256 to 16TB Memory 1 to 4 nodes (5U) per system Built-in initial Elastic CoD days 6 Power Enterprise Servers with POWER8 processors GA = 5 June 2015 Power E880 192 cores @ 4.02 GHz 1 – 4 node, 4 – 8S (12c) Up to 16 TB memory GA = 4Q14 9119-MHE 128 cores @ 4.35 GHz 1 – 4 node, 4 – 8S (8c) Up to 16 TB memory 1st & 2nd node 3rd & 4th node 80 cores @ 4.19 GHz 1 – 2 node, 4 – 8S (10c) Up to 8* TB memory Power E870 9119-MME 64 cores @ 4.02 GHz 1 – 2 node, 4 – 8S (8c) Up to 8* TB memory 1st & 2nd node * 8TB was originally SOD as only 4TB initially available. 8TB announced April 2015 with June 2015 GA date 7 © Copyright IBM Corporation 2015 POWER8 Enterprise E870 E870 Node 1 System Control Unit Node 2 Node 32-core 4.02 GHz 40-core 4.19 GHz 1 Node 32 cores 40 cores 2 Nodes 64 cores 80 cores * IBM Statement of Direction for 2015. For more details see the IBM Power E880 Announcement Letter released on October 6, 2014. IBM’s statements regarding its plans, directions, and intent are subject to change or withdrawal without notice at IBM’s sole discretion. © Copyright IBM Corporation 2015 POWER8 Enterprise E870 and E880 E870 Node 4 Node 1 System Control Unit Node 2 Node 3 E880 Node 32-core 4.02 GHz 40-core 4.19 GHz 32-core 4.35 GHz 48-core 4.02 GHz* 1 Node 32 cores 40 cores 32 cores 48 cores 2 Nodes 64 cores 80 cores 64 cores 96 cores 3 Nodes 96 cores 144 cores 4 Nodes 128 cores 192 cores * IBM Statement of Direction for 2015. Ann planned 2Q2015 GA 2Q2015 © Copyright IBM Corporation 2015 POWER8 Enterprise E870 and E880 rPerf E870 Node 4 Node 1 System Control Unit Node 2 Node 3 *Using E880 Node 32-core 4.02 GHz 40-core 4.19 GHz 32-core 4.35 GHz 48-core 4.02 GHz* 1 Node 674.5 856 716 976.4 2 Nodes 1349 1711.9 1432.5 1952.9 3 Nodes 2148.8 2929.3 4 Nodes 2865 3905.8 SMT8 © Copyright IBM Corporation 2015 High-end system capacity increases with POWER8 Power E880 can provide similar capacity as the Power 795 with ½ the cores 192c Up to 39% more capacity 128c 256c 128c 128c 64c Power 595 3,906 80c 64c 64c 96c ----- Power 795 ----- Power 780 Power 795 Power E870 Power E880 rPerf performance for fully-configured systems. Power 795 rPerf using 64c LPARs © 2014, 2015 International Business Machines Corporation 11 Enterprise upgrade paths (Keep System Serial Number) New - Upgrade within E880 from 32-core node to 48-core nodes These upgrades must be ordered by Nov. 30, 2015 2014 POWER7 780 2015 2015 9179-MHC 2014 POWER7 780 POWER7+ 780 9179-MHB One or two nodes 9179-MHD POWER6 570 9117-MMA POWER7 770 POWER6 upgrades to POWER7+ POWER6+ upgrades to POWER7+ POWER7 upgrades to POWER7+ Three or four nodes POWER8 E880 2015 Enterprise Power High-end 9117-MMC POWER7 770 POWER7+ 770 9117-MMB 9117-MMD 2014 One or two nodes POWER6 570 9117-MMA Clients that have 9406-MMA MUST upgrade to 9117-MMA prior to upgrading to the B, C, or D models 12 *All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. POWER8 E870 Enterprise Power Midrange © Copyright IBM Corporation 2015 April 2015 Processor Core Activation Features E870 E880 9119-MME 9119-MHE Processor SCM feature #core (c) GHz #EPBA 32c 4.02 GHz #EPBC 40c 4.19 GHz #EPBB 32c 4.35 GHz #EPBD 48c 4.0 GHz Static activation #EPBJ #EPBL #EPBK #EPBM Mobile-enabled (static) activation #EPBN #EPBQ #EPBP #EPBR Mobile activation #EP2S #EP2S #EP2T #EP2T Power Integrated Facility for Linux (IFL) Quantity 4 #ELJ5* #ELJ7* #ELJ6* #ELJ8* Minimum of 8 cores must be activated (any of the above activations) Notes: Activations associated with Power IFL can only be used for Linux partitions Static activations can be converted to mobile activations. There is a minimum number of static activations required on the server. It is less expensive to buy a mobile-enabled static activation and convert it to a mobile activation than to buy a static activation and convert it to a mobile activation 14 © Copyright IBM Corporation 2015 Summary Power E880 / E870 PCIe Enhancements • Additional PCIe Gen3 I/O Drawer Config – Up to 4 drawers per node -- 2X increase in drawers (fulfilling SOD) • Up to 192 adapters on 4-node Power E880 • Up to 96 adapters on 2-node Power E870 – Ability to configure less than 2 drawers per node – Ability to configure ½ drawers • Support for more PCIe adapters in System node – 15 previously announced features now supported (fulfilling SOD) – 4 new, additional PCIe adapter features added • Support for more PCIe adapters in PCIe Gen3 I/O Drawer – 4 previously announced features now supported (fulfilling SOD) – 5 new additional PCIe adapter features added 15 © Copyright IBM Corporation 2015 PCIe Adapter Details - E870/E880 Adapters available on POWER7+ now also supported in system node • • • • • • • • • • • • • • • PCIe LP POWER GXT145 Graphics Accelerator (#5269) PCIe LP 4Gb 2-Port Fibre Channel Adapter (#5276) PCIe2 LP 2-Port 4X IB QDR Adapter 40Gb (#5283) PCIe2 LP 2-port 10GbE SR Adapter (#5284) PCIe2 LP 3D Graphics Adapter x1 (#EC41) PCIe2 LP 4-Port (10GbE+1GbE) SR+RJ45 Adapter (#EN0T) PCIe2 LP 4-port (10GbE+1GbE) Copper SFP+RJ45 Adapter (#EN0V) PCIe LP 2-Port Async EIA-232 Adapter (#EN28) PCIe2 LP 2-Port 10GbE RoCE SFP+ Adapter (#EC27) PCIe LP 2-Port 1GbE TX Adapter (#5281) PCIe LP 2-Port 1GbE SX Adapter (#5274) PCIe LP 4-Port 10/100/1000 Base-TX Ethernet Adapter (#5271) PCIe LP 10Gb FCoE 2-port Adapter (#5270) PCIe2 4-port (10Gb FCoE & 1GbE) LR&RJ45 Adapter (#EN0N) PCIe LP 4-Port Async EIA-232 Adapter (#5277) 27 PCIe adapter features added April 2015 New adapters in system node • • • • PCIe3 LPX 4-port 10GbE SFP+ Copper Adapter (#EN16) PCIe3 LPX 4-port 10GbE SR Adapter (#EN18) PCIe3 LP 2-port 10GbE NIC&RoCE SFP+ Copper Adapter (#EC37) PCIe3 LP 2-port 10GbE NIC&RoCE SR Adapter (#EC2M) Adapters available on POWER7+ now also supported in PCIe Gen3 I/O Drawer • • • • PCIe2 4-Port (10GbE & 1GbE) SR&RJ45 Adapter (#5744) 10Gb FCoE PCIe Dual Port Adapter (#5708) PCIe 380MB Cache Dual Port 3Gb SAS RAID Adapter (#5805) PCIe2 4-port (10Gb FCoE & 1GbE) LR&RJ45 Adapter (#EN0M) New adapters in PCIe Gen3 I/O Drawer • • • • 16 PCIe3 4-port 10GbE SFP+ Copper Adapter (#EN15) PCIe3 4-port 10GbE SR Adapter (#EN17) PCIe3 2-port 10GbE NIC&RoCE SFP+ Copper Adapter (#EC38) PCIe3 2-port 10GbE NIC&RoCE SR Adapter (#EC2N) © Copyright IBM Corporation 2015 Power EXP24S Drawer & HDD/SSD EXP24S I/O Drawer (#5887) I/O maximums expanded in April 2015 announcement 2U Form factor 24 SFF-2 SAS bays For SSD or for HDD Connects to PCIe SAS adapters Power 770 Power 780 Power E870 Power E880 Max qty EXP24S 126 126 128 168 Max qty HDD in EXP24S 3024 3024 3072 4032 If that isn’t enough, ask for more Notes: • max of 16 EXP24s per PCIe Gen3 I/O drawer. Rule for good cable management practices. • it is a good practice to keep the PCIe Gen3 I/O drawer in the same rack as the EXP24S to minimize SAS cable lengths. Shorter SAS cables are thinner and less expensive. Using the 8-inch rack extender for 7014-T42 rack for configs with lots of I/O cables is a good thing for cable management. • Earlier generation I/O drawers such as #5886 or #5802 or #EXP30 not supported 17 © Copyright IBM Corporation 2015 Power E850 18 © Copyright IBM Corporation 2015 Power E850 The most agile 4-socket system in the marketplace, designed for big data with flexible capacity and guaranteed utilization Redesigned 4-socket, 4U POWER8 system Improved performance, RAS, and efficiency 2 – 4 POWER8 processors – up to 3.7GHz Up to 2TB* memory – 2X increase over Power 750 11 PCIe Gen3 slots Dual 10Gb ethernet ports (x8 slot) 2 Integrated SAS controllers 8 SFF (2.5”) SAS bays + 4 SSD (1.8”) Up to 4 PCIe Gen3 I/O drawers Active Memory Mirroring for Hypervisor (option) CUoD, Power IFL & Elastic Capacity on Demand 8408-E8E • • • • • 24 to 48 active cores at 3.0 GHz 20 to 40 active cores at 3.3 GHz 16 to 32 active cores at 3.7 GHz Small Software tier 3 years of service (varies by country) *Statement of Direction for 4TB of memory on Power E850 All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. © 2014, 2015 International Business Machines Corporation 19 Seamless capacity for non-disruptive growth Power E850 Capacity on Demand • CoD benefits – Quickly add additional processor and/or memory in non-disruptive manner – Enhances system reliability by providing processor sparing – System growth through activations, even after processors withdrawn – More granular price points, to match needs and growth – Inactive cores not subject to maintenance – Inactive cores are not subject to PowerVM licensing • CoD offering – – – – – 20 For all processor frequencies Permanent (CUoD) and Temporary (Elastic, Utility, Trial) activations Used for cores and memory greater than 50% of the server’s capacity Consistent activation rules for all configurations Very granular, grow in increments of just one processor core © 2014, 2015 International Business Machines Corporation Flexible, affordable, high-performance capacity for Linux applications Power E850 Integrated Facility for Linux Power IFL • Simplify operations and reduce complexity by colocating applications on a more scalable and reliable server • Streamline access to data and applications via secure, high-performance virtual networking • Grow seamlessly and accelerate deployment of new applications and services • Reduce overhead by leveraging existing production and disaster recovery infrastructure • Possible to have an all IFL configuration if desired 21 © 2014, 2015 International Business Machines Corporation Virtual stack consisting of : 4 x CUoD processor activations 32 GB CUoD memory activations 4 x PowerVM for PowerLinux license entitlement Scales in increments of 4 cores Available on : Power E850 Power E870 Power E880 21 Power E850 3 GHz 3.35 GHz 3.7 GHz 8 8 8 8 • 16 – 32 core system • 2, 3 or 4 sockets • 8-core processor modules 10 10 10 10 • 20 – 40 core system • 2, 3 or 4 sockets • 10-core processor modules © 2014, 2015 International Business Machines Corporation 12 12 12 • 24 – 48 core system • 2, 3 or 4 sockets • 12-core processor modules • Min active cores = 50% of system max • Min active memory = 50% of installed • Capacity on Demand & Power IFL 22 12 Power Enterprise Servers with POWER8 processors • New E880 with up to 192 cores @ 4GHz (1-4 nodes) • E880 now supports up to 128 cores @ 4.35GHz (3rd/4th node ) • Up to 16 TB memory • Up to 16 PCIe I/O Expansion drawers (0-4 per node) • MES upgrades from E880 4.35GHz, POWER7+ Power 780 & Power 770 192 cores @ 4 GHz Power E880 9119-MHE 1 – 4 node, 4-16S (12c) Up to 16 TB Memory 128 cores @ 4.35 GHz 1 – 4 node, 4-16S (8c) Up to 16 TB Memory 80 cores @ 4.19 GHz 1 – 2 node, 4 - 8S (10c) Up to 8TB Memory Power E870 9119-MME • Up to 8 TB memory (4TB per node w/ 128GB DIMM) • Up to 8 PCIe I/O Expansion drawers (0-4 per node) 64 cores @ 4 GHz 1 – 2 node, 4-8S (8c) Up to 8TB Memory 48 cores @ 3 GHz 2-4S (12c) Up to 2TB* Memory Power E850 8408-E8E 40 cores @ 3.35 GHz 2-4S (10c) Up to 2TB* Memory • • • • New Power E850 4-socket/4U system up to 3.7GHz 16 to to 48 cores with Capacity on Demand 8 SAS bays + 4SSD for local storage Up to to 4 PCIe Expansion drawers 32 cores @ 3.7 GHz 2-4S (8c) Up to 2TB* Memory *Statement of Direction for 4TB of memory on Power E850. All statements regarding IBM’s future plans and direction are for information only and are subject to change without notice. © 2014, 2015 International Business Machines Corporation 24 Power S824L Power S824 Power E850 Power E870 (1 Node) MTM 8247-42L 8286-42A 8408-E8E 9119-MME Sockets 2 2 4 4-8 Max Cores / Frequency 20 @ 3.42 GHz 24 @ 3.02 GHz 12 @ 3.89 GHz 16 @ 4.15GHz 24 @ 3.55 GHz 32 @ 3.72 GHz 40 @ 3.35 GHz 48 @ 3.02 GHz 64 @ 4.02GHz 80 @ 4.2 GHz Max Memory 1 TB 2 TB 2 TB* 8 TB Max PCI slots 7 PCIe x8 4 PCIe x16 7 PCIe x8 4 PCIe x16 3 PCIe x8 8 PCIe x16 16 PCIe x16 SFF SAS bays 18 18 8 0 Integrated split backplane Yes Yes Yes No Max PCIE I/O Drawers 2 2 4 8 LPARS 20 per core 20 per core 20 per core 20 per core Height 4U 4U 4U 12U Operating System Linux AIX, IBM i, Linux AIX, Linux AIX, IBM i, Linux Active Memory Mirroring for Hypervisor No No Yes (option) Yes (Standard) PowerVM Optional Optional Optional PowerVM EE License Entitlement included Capacity on Demand No No CUoD, Power IFL, Elastic, Utility, Trial COD CUoD, Elastic, Utility, Trial Power Enterprise Pools No No No Yes Installation Customer Set-up Customer Set-up Customer Set-up IBM installed Warranty 3yr (9x5 NBD) 3yr (9x5 NBD) 3yr warranty services included (varies by country) 1yr (24x7 4hr) *Statement of Direction for 4TB of memory on Power E850 All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. © 2014, 2015 International Business Machines Corporation 25 Midrange system capacity increases with POWER8 Power E850 offers over 2X more system capacity than POWER7 750 D. and up to 56% more system capacity than POWER7+ 750/760 48c +49% more per-core vs fastest POWER7+ 48c 32c 32c 40c 32c 48c 32c 24c ----- Power 750 ----- ----- Power 750 ----- ----- Power 760 ----- ---------- Power E850 ---------- © 2014, 2015 International Business Machines Corporation 26 Power E850 8408-E8E Processor Modules 2–4 CDIMM slots 16 – 32 PCIe Gen3 slots 7 - 11 HMC ports Serial port USB-2 ports USB-3 ports Fans DVD bay 4U SFF-3 SAS bays Op Panel USB-3 ports 1.8-inch SSD bays 27 © Copyright IBM Corporation 2015 E850 Processor Modules and Activations More modules = more memory & more I/O Number of processor modules CDIMM memory slots PCIe slots in system unit Max PCIe Gen3 I/O Drawers 2 3 4 16 7 2 24 9 3 32 11 4 E850 offers CoD processor flexibility 1st & 2nd processor modules 100% permanently activated 3rd & 4th processor modules optionally activated Elastic CoD, Utility CoD, Trial CoD 29 © Copyright IBM Corporation 2015 E850 Memory Bandwidth & Organization Up to 32 total DDR ports DRAM Chips Memory Buffer 16-64* GB 16MB 16-64* GB 16MB 16-64* GB 16-64* GB Up to 410 GB/s Up to 8 high speed channels, 8 GHz per channel * 16MB 16-64* GB 16MB 16-64* GB 16MB 16MB 16-64* GB 16MB 16MB 16-64* GB (2 bytes read + 1 byte write -- per channel) Up to 192 GB/s sustained Processor Module Up to 512 GB / Socket (with eight 64GB CDIMMs) SOD for additional memory capacity 30 © Copyright IBM Corporation 2015 Memory Performance/Configuration Insights • Can Mix different size CDIMMs – Can not mix sizes within a pair – Can mix different size pairs on a module Memory slot Memory slot Memory slot Memory slot POWER8 module Memory slot Memory slot Memory slot Memory slot • Always plug in pairs – Minimum of four CDIMMs per processor module: • 2-socket = minimum of eight DIMMs, 3-socket = 12 DIMMs, 4-socket = 16 DIMMs – Minimum of 50% activation or 128GB activation – which ever is larger •Performance rules of thumb U Performance disclaimer “it depends”, but should apply to the majority of typical commercial client situations – More DIMMs = more bandwidth. Thus for max memory performance fill all DIMM slots. (this leaves no room for growth without parts on floor.) • Note that for many applications which aren’t memory dependent or when the server isn’t running high utilization, having some empty slots is probably not very significant. – Mixing different size DIMMs. For max performance make all DIMMs the same size. • Impact of having different sizes is probably very modest for most systems 32 © Copyright IBM Corporation 2015 Memory Bandwidth per Socket for 4-Socket Servers E850 POWER8 POWER7+ POWER7 POWER6 0 50 100 150 200 GB/Sec 33 © Copyright IBM Corporation 2015 Power 4-Socket IO Bandwidth E850 POWER8 POWER7+ POWER7 POWER6 0 50 100 150 200 250 300 350 GB/Sec 35 © Copyright IBM Corporation 2015 Power E850 Block Diagram – 2 Processor Module CEC Planar 8Gbps Proc Mod 0 DMI-A DMI-B DMI-C DMI-D A0 A2 A1 Chip-0 X1 8B CDIMM DMI-A DMI-B DMI-C DMI-D A2 A1 A0 Chip-1 48 PCIe G3 lanes 36 RAID Backplane Chip-0 PHB1 x8 PSI-0 FSI 8Gbps DMI-A DMI-B DMI-C DMI-D Chip-0 X1 8B CDIMM DMI-A DMI-B DMI-C DMI-D Chip-1 PSI-1 48 PCIe G3 lanes C5 FSP2 Card 2x1GE, 1 Serial 2 USB 2.0 Chip-0 PHB1 x8 PCIe Gn3 x16 FHHL slot C10 Chip-1 PHB1 x8 DVD SAS Cntrl RAID #2 Chip-0 PHB1 x8 Chip-1 PHB0 x16 DASD BP 8 SFF 4 1.8” SSD SAS Cntrl RAID #1 Proc Mod 1 A2 A1 A0 Chip-0 PHB0 x16 Chip-1 PHB1 x8 Op-panel A0 A2 A1 Chip-0 PHB0 x16 Chip-1 PHB0 x16 PCIe Gn3 x16 FHHL slot C12 PCIe Gn3 x8 FHHL slot C11 C11 for LAN adapter for IBM Mfg/Test S0P0 PCIe Gen3 x16 FHHL slot C8 PCIe Gen3 x16 FHHL slot C9 S0P1 PCIe Gn3 x8 FHHL slot C6 PEX S1P8 8732 PCIe Gn3 x8 FHHL slot C7 S1P9 TI TUSB7340 USB 3.0 (2F,2R) IO Planar © Copyright IBM Corporation 2015 Power E850 Block Diagram – 3 Processor Module CEC Planar 8Gbps CDIMM Proc Mod 2 DMI-A DMI-B DMI-C DMI-D A0 A2 A1 Chip-0 X1 8B DMI-A DMI-B DMI-C DMI-D A2 A1 A0 Chip-1 48 PCIe G3 lanes Chip-1 PHB0 x16 8Gbps Chip-0 PHB0 x16 Proc Mod 0 DMI-A DMI-B DMI-C DMI-D A0 A2 A1 Chip-0 X1 8B CDIMM DMI-A DMI-B DMI-C DMI-D A2 A1 A0 Chip-1 48 PCIe G3 lanes DVD 37 SAS Cntrl RAID #2 RAID Backplane Chip-0 PHB1 x8 Chip-0 PHB1 x8 PSI-0 FSI 8Gbps DMI-A DMI-B DMI-C DMI-D Chip-0 X1 8B CDIMM DMI-A DMI-B DMI-C DMI-D Chip-1 PSI-1 48 PCIe G3 lanes C5 FSP2 Card 2x1GE, 1 Serial 2 USB 2.0 Chip-0 PHB1 x8 PCIe Gn3 x16 FHHL slot C10 Chip-1 PHB1 x8 DASD BP 8 SFF 4 1.8” SSD SAS Cntrl RAID #1 Chip-1 PHB0 x16 Op-panel Proc Mod 1 A2 A1 A0 Chip-0 PHB0 x16 PCIe Gen3 x16 FHHL slot C4 Chip-1 PHB1 x8 PCIe Gen3 x16 FHHL slot C3 A0 A2 A1 Chip-0 PHB0 x16 Chip-1 PHB0 x16 PCIe Gn3 x16 FHHL slot C12 PCIe Gn3 x8 FHHL slot C11 C11 for LAN adapter for IBM Mgf/Test S0P0 PCIe Gen3 x16 FHHL slot C8 PCIe Gen3 x16 FHHL slot C9 S0P1 PCIe Gn3 x8 FHHL slot C6 PEX S1P8 8732 PCIe Gn3 x8 FHHL slot C7 S1P9 TI TUSB7340 USB 3.0 (2F,2R) IO Planar © Copyright IBM Corporation 2015 Power E850 Block Diagram – 4 Processor Module CEC Planar 8Gbps CDIMM Proc Mod 2 DMI-A DMI-B DMI-C DMI-D Chip-0 X1 8B DMI-A DMI-B DMI-C DMI-D 2B @ 5.33 Gbps A0 A2 A1 A2 A1 A0 Chip-1 Proc Mod 3 A0 A2 A1 Chip-1 PHB0 x16 8Gbps A0 A2 A1 X1 8B DMI-A DMI-B DMI-C DMI-D 38 RAID Backplane Chip-0 PHB1 x8 PSI-0 FSI Chip-0 PHB0 x16 8Gbps DMI-A DMI-B DMI-C DMI-D Chip-0 X1 8B CDIMM DMI-A DMI-B DMI-C DMI-D Chip-1 PSI-1 48 PCIe G3 lanes C5 FSP2 Card 2x1GE, 1 Serial 2 USB 2.0 PCIe Gen3 x16 FHHL slot C1 Chip-0 PHB1 x8 PCIe Gn3 x16 FHHL slot C10 PCIe Gen3 x16 FHHL slot C2 Chip-1 PHB1 x8 DVD SAS Cntrl RAID #2 Chip-1 PHB0 x16 DASD BP 8 SFF 4 1.8” SSD Chip-0 PHB1 x8 Proc Mod 1 A2 A1 A0 Chip-0 PHB0 x16 PCIe Gen3 x16 FHHL slot C4 Chip-1 PHB1 x8 PCIe Gen3 x16 FHHL slot C3 A0 A2 A1 A2 A1 A0 Chip-1 48 PCIe G3 lanes SAS Cntrl RAID #1 Chip-1 Chip-1 PHB0 x16 Chip-0 CDIMM 48 PCIe G3 lanes Proc Mod 0 DMI-A DMI-B DMI-C DMI-D 8Gbps DMI-A DMI-B DMI-C DMI-D Chip-0 PHB0 x16 CDIMM Op-panel X1 8B A2 A1 A0 48 PCIe G3 lanes DMI-A DMI-B DMI-C DMI-D Chip-0 Chip-0 PHB0 x16 Chip-1 PHB0 x16 PCIe Gn3 x16 FHHL slot C12 PCIe Gn3 x8 FHHL slot C11 C11 for LAN adapter for IBM Mgf/Test S0P0 PCIe Gen3 x16 FHHL slot C8 PCIe Gen3 x16 FHHL slot C9 S0P1 PCIe Gn3 x8 FHHL slot C6 PEX S1P8 8732 PCIe Gn3 x8 FHHL slot C7 S1P9 TI TUSB7340 USB 3.0 (2F,2R) IO Planar © Copyright IBM Corporation 2015 E850 OS 41 © Copyright IBM Corporation 2015 E850 Supported OS Levels If installing AIX LPAR with any I/O configuration: – AIX V7.1 TL3 SP5 and APAR IV68444, or later – AIX V7.1 TL2 SP7, or later (planned availability September 30, 2015) – AIX V6.1 TL9 SP5 and APAR IV68443, or later – AIX V6.1 TL8 SP7, or later (planned availability September 30, 2015) If installing AIX Virtual-I/O-only LPAR: – AIX V7.1 TL2 SP1, or later – AIX V7.1 TL3 SP1, or later – AIX V6.1 TL8 SP1, or later – AIX V6.1 TL9 SP1, or later If installing VIOS: – VIOS 2.2.3.51 or later If installing the Linux operating system: • Big Endian – Red Hat Enterprise Linux 7.1, or later – Red Hat Enterprise Linux 6.6, or later – SUSE Linux Enterprise Server 11 Service Pack 3 and later Service Packs • Little Endian – Red Hat Enterprise Linux 7.1, or later – SUSE Linux Enterprise Server 12 and later Service Packs – Ubuntu 14.04.2, or later – Ubuntu 15.04 42 © Copyright IBM Corporation 2015 Power E850 • AIX license tier: – small • PVU – 100 except for Power IFL cores which are 70 • HMC – Optional unless doing temporary CoD or SR-IOV • Firmware – 8.3 or later required 43 © Copyright IBM Corporation 2015 E850 Adapters 44 © Copyright IBM Corporation 2015 Power E850 PCIe Adapters Supported as of June 2015 (page 1) in System Unit Ethernet NIC Ethernet NIC Ethernet NIC Ethernet NIC Ethernet NIC & RoCE Ethernet NIC & RoCE Ethernet NIC & RoCE Ethernet NIC & SR-IOV Ethernet NIC & SR-IOV Ethernet NIC & SR-IOV & FCoE Ethernet NIC & SR-IOV & FCoE Ethernet NIC & SR-IOV & FCoE Ethernet NIC & FCoE Ethernet NIC Ethernet NIC & RoCE 45 4-port 1GbE RJ45 2-port 10GbE 10GBase-T RJ45 4-port 10GbE+1GbE SR optical 4-port 10GbE+1GbE Copper twinax 2-port 10GbE SR optical (no NIM) 2-port 10GbE SR optical 2-port 10GbE Copper twinax 4-port 10GbE SR optical 4-port 10GbE Copper twinax 4-port 10GbE+1GbE SR optical+RJ45 4-port 10GbE+1GbE Copper Twinax+RJ45 4-port 10GbE+1GbE LR optical +RJ45 2-port 10GbE SR optical 2-port 10GbE SR optical 2-port 40GbE QSFP+ * Supported, but not orderable as new adapter ** Supported, but not orderable as new adapter in most countries #5899 #EN0W #EN0S #EN0U #EC30 #EC2N #EN38 #EN17 #EN15 #EN0H #EN0K #EN0M #5708 * #5287 * #EC3B NEW NEW NEW NEW © Copyright IBM Corporation 2015 Power E850 PCIe Adapters Supported as of June 2015 (page 2) in System Unit 46 Fibre Channel Fibre Channel Fibre Channel 2-port 8Gb 4-port 8Gb 2-port 16Gb #5735 #5729 #EN0A Communications 2-port Async RS232 #EN27 SAS RAID SAS Tape/DVD SAS RAID SAS RAID SAS RAID/Tape/DVD 4-port no-cache PCIe3 for SSD/HDD 4-port tape/DVD PCIe3 4-port huge-cache PCIe3 for SSD/HDD 4-port huge-cache PLUS PCIe3 for SSD/HDD 2-port no-cache PCIe1 for HDD or tape or DVD #EJ0J #EJ10 #EJ0L #EJ14 #5901 * Supported, but not orderable as new adapter ** see withdrawal announcements NEW © Copyright IBM Corporation 2015 Power E850 PCIe Adapters Supported as of June 2015 (page 3) in System Unit 47 InfiniBand (IB) 2-port QDR IB SR optical #5285 Graphics Graphics 2D graphics for general use 3D graphics for RHEL7 #5748 #EC42 USB 4-port USB-3 #EC46 © Copyright IBM Corporation 2015 More PCIe Adapters supported in PCIe Gen3 I/O Drawer See the I/O drawer list. Includes Older 1Gb Ethernet adapters: #5767, #5768, #5717, #5769, #5744 Crypto card 48 #EJ28 © Copyright IBM Corporation 2015 E850 Storage Backplane 49 © Copyright IBM Corporation 2015 Power E850 – SAS Bays (Front View) Hot plug fans for Memory/Proc/PCIe cards DVD 4U Eight SFF-3 SAS bays HDD and/or SSD Hot plug USB-3 ports DVD bay Hot plug Operator Panel Four 1.8-inch SSD bays Hot plug HDD/SSD and DVD run by integrated SAS controllers. Pick one of 3 options: A) split backplane, two controllers B) dual controller with cache, or C) dual controller without cache 50 © Copyright IBM Corporation 2015 Power E850 Storage Backplane • All E850 have a storage backplane with – 8 SFF-3 SAS bays (HDD and/or SSD) & 4 1.8-inch SAS bays (SSD) – DVD bay – Integrated SAS controller for above bays • High performance, based on IBM PCIe Gen3 SAS technology • Easy Tier function supported in all backplane flavors • Can have both SSD and/or HDD in all backplane flavors • Select one of three integrated SAS controller options – #EPVN: Dual controllers with write cache • Effectively up to 7GB write cache with compression – #EPVP: Dual controllers with zero write cache – #EPVQ: Split backplane (2 independent controllers without write cache) • Each controller runs 4 SFF-3 bays and 2 1.8-inch SSD bays (split top/bottom) – Can change the configuration and MES order a different backplane in the field. Be careful to backup data if changing arrays. 51 © Copyright IBM Corporation 2015 E850 Storage Backplane Options • Must select one of three SAS controller options: #EPVQ #EPVP #EPVN 6+6 SAS bays 12 SAS bays 12 SAS bays 2x (4 SFF-3 & 2 1.8”) (8 SFF-3 & 4 1.8”) (8 SFF-3 & 4 1.8”) 2 SAS controllers 0 GB cache DVD bay Dual SAS controlrs 0 GB cache DVD bay Dual SAS contrllrs 7.2** GB cache DVD bay $ 3000 $ 6000 $ 3000 AIX / Linux Easy Tier Function JBOD RAID 0 / 1 RAID 5 / 6 / 10 RAID 5T2 (Easy Tier) RAID 6T2 (Easy Tier) RAID 10T2 (Easy Tier) Split backplane yes yes yes yes yes no no Yes Yes yes yes no yes Yes Yes yes Yes no yes yes no yes yes yes yes yes no ** 1.8GB physical write cache provides up to effectively 7.2GB with compression USA IBM list price. Price is subject to change. Reseller prices will vary. 52 © Copyright IBM Corporation 2015 PCIe Gen3 IO Expansion Drawer 53 © Copyright IBM Corporation 2015 PCIe Gen3 I/O Expansion Drawer Announced 2014 Feat #EMX0 Front view 12 PCIe Gen3 slots 4U drawer Full high PCIe slots Hot plug PCIe slots Modules not hot plug Feat #EMXF Rear view Feat #EMXF Fan-out Module 6 PCIe Gen3 Slots 4 x8 & 2 x16 Fan-out Module 6 PCIe Gen3 Slots 4 x8 & 2 x16 Use same Blind Swap Cassette (BSC) as used in #5802/5877/5803/5873 I/O drawer 54 © Copyright IBM Corporation 2015 PCIe Gen3 I/O Expansion Drawer Announced 2014 2015: growth and more configuration flexibility Feat #EMX0 Front view Enterprise add 2015 • • • • Scale-out add 2015 12 PCIe Gen3 slots 4Uincrease drawerPCIe slot max Double the max drawers per node • Dramatically Full high PCIe slots Allow just one drawer per node • Very similar config rules to Enterprise Hot plug PCIe slots Allow using “½” drawers • Can use “½” drawer for entry Modules not hotprice plug Support more kinds of PCIe adapters Feat #EMXF Rear view Feat #EMXF Fan-out Module 6 PCIe Gen3 Slots 4 x8 & 2 x16 Fan-out Module 6 PCIe Gen3 Slots 4 x8 & 2 x16 Use same Blind Swap Cassette (BSC) as used in #5802/5877/5803/5873 I/O drawer 55 © Copyright IBM Corporation 2015 Min/Max PCIe I/O Drawer per E870/E880 Node 2014 One system node One system node + 1 0 2 0 or 2 PCIe Gen3 I/O Drawers in 2014 (max 4 fan-out modules per node) 59 © Copyright IBM Corporation 2015 Min/Max PCIe I/O Drawer per E870/E880 Node 2015 One system node One system node One system node + 0 1 2x more drawers PLUS More flexibility One system node One system node + + + 1 1 2 2 2 3 3 1 4 0, 1, 2, 3 or 4 PCIe Gen3 I/O Drawers in 2015 (max 8 fan-out modules per node) Requires 8.3 firmware level available June 2015 60 © Copyright IBM Corporation 2015 Min/Max PCIe I/O Drawer per E870/E880 Node 2015 One system node 0 One system node One system node + 1 One system node One system node + + + 1 1 2 2 2 3 3 1 For even more flexibility – can choose to have “1/2” drawers. Thus any of the drawers could have a single 6-slot fan-out module 4 0, ½, 1, 1½, 2, 2½, 3, 3½ or 4 PCIe Gen3 I/O Drawers in 2015 (max 8 fan-out modules per node) Requires 8.3 firmware level available June 2015 61 © Copyright IBM Corporation 2015 PCIe Gen3 I/O Drawer E870/E880 PCIe Slot Counts 2015 Sample quantities of PCIe drawers on the server PCIe slots per 1-node server PCIe slots per 2-node server PCIe slots per 3-node server PCIe slots per 4node server 0 8 16 24 32 1 2 3 4 18 26 34 42 12 drwr + 6 node 12 drwr + 14 node 12 drwr + 22 node 12 drwr + 30 node 28 36 44 52 24 drwr + 4 node 24 drwr + 12 node 24 drwr + 20 node 24 drwr + 28 node 38 46 54 62 36 drwr + 2 node 36 drwr + 10 node 36 drwr + 18 node 36 drwr + 26 node 48 56 64 72 48 drwr + 0 node 48 drwr + 8 node 48 drwr + 16 node 48 drwr + 24 node 76 84 92 72 drwr + 4 node 72 drwr + 12 node 72 drwr + 20 node 96 104 112 96 drwr + 0 node 96 drwr + 8 node 96 drwr + 16 node 6 n/a 8 n/a 12 n/a n/a 16 n/a n/a 144 152 144 drwr + 0 node 144 drwr + 8 node Not all possible quantities of drawers shown, nor are “1/2” drawers shown 62 n/a 192 192 drwr + 0 node maximum © Copyright IBM Corporation 2015 PCIe Gen3 I/O expansion drawer PCIe Slot Math 2U 1-socket 2U 2-socket One filled 2U 2-socket Two filled 4U 1-socket *** 4U 2-socket One filled 4U 2-socket Two filled S812L S822 S822, S822L S814 S824 S824, S824L* PCIe slots in system unit 6 6 9 7 7 11 x16 slots in system unit 2 2 4 2 2 4 Max PCIe Gen3 I/O Drawer ½ ½ 1 1 1 2 PCIe Gen3 Drawer slots 6 6 12 12 12 24 PCIe slots used for Optical Cable Adapter 2** 2** 4** 2 2 4 Total Max PCIe slots 6-2+6 = 10 6-2+6 = 10 9-4+12 = 17 7-2+12 = 17 7-2+12 = 17 11-4+24 = 31 Nearly 2x more slots Over 2x more nearly 3x * If S824L using a GPU, can not have I/O drawer ** 2U uses double-wide Optical Cable Adapter which uses two PCIe slots per fan-out module. Because of x16 slot location, can only use half of the x16 slots for attaching an I/O drawer. *** requires a 6-core or 8-core server. 4-core server doesn’t support I/O drawer 63 © Copyright IBM Corporation 2015 IBM Scale-Out Power Systems Open Innovation to put data to work Power Systems with POWER8 Built with open innovation to put data to work What’s NEW for Scale-out Power Systems Designed for big data Ann Apr. 28th GA June 9th • For workloads requiring highest single thread performance 8 core fast offering to S822 and S822L, delivering 16 cores at 4.15 GHz • Double Scale-Out Power S814 and S824L Systems memory capacity • Expanded Linux Distributions, delivering the promise of ease of porting Red Hat Enterprise Linux 7.1 support little endian on Power Systems and now orderable from IBM Open innovation platform • ( June Ann/GA ) NVIDIA K80 GPU accelerator available for S824L Superior cloud economics • For clients who want directly attached SSD/disk per VM with minimal VIOS virtualization External PCIe Gen3 IO extension drawer to all POWER8 scale-out • Add flexibility to fit in different data center environment Expanding S824L offering with Non-GPU acceleration version available 110V power supply available for S814 Rack mount form factor (SOD ) Water Cooling features available for S822 and S882L 65 IBM – Page 65 © 2014 IBM Corporation Scale-out Systems built with POWER8 • Leadership Data / Analytics performance in consumable Scale out form factor; Foundation for Big Data / Analytic solutions • Portfolio is complemented by a full commitment to support an open stack of software - • Ubuntu, SUSE, RedHat, PowerKVM, and Open Stack S812L • 1-socket, 2U • Linux only New in 2Q15 66 IO Expansion Drawer Offerings to compete head to head with x86 Linux S822L • • • • • • 2-socket, 2U Up to 24 cores 1 TB memory 9 PCI Gen3 slot Linux only NEBs option • 8-core, 4.15 GHz option • PCIe Gen3 I/O Drawer • SOD: Water cooling S822 • • • • • • • 2-socket, 2U Up to 20 cores 1 TB memory 9 PCIe Gen 3 AIX & Linux PowerVM only NEBs option • 8-core, 4.15 GHz option • PCIe Gen3 I/O Drawer • SOD: Water cooling S814 • • • • • • • 1-socket, 4U Up to 8 cores 512 GB memory 7 PCIe Gen 3 AIX, IBM i, Linux PowerVM only 4core/P05 (IBM i) • 1 TB memory • 110 v power • PCIe Gen3 I/O Drawer S824L • • • • • • • • • • 2-socket, 4U Up to 24 cores Linux NVidia GPU Full offering (GPU not required) 2TB of memory 8/16-core 4.15GHz and 24-core 3.52GHz option PowerKVM (2H15) Nvidia K80 GPU PCIe Gen3 I/O Drawer S824 • • • • • 2-socket, 4U Up to 24 cores 2 TB memory 11 PCIe Gen 3 AIX, IBM i, Linux • PowerVM only • PCIe Gen3 I/O Drawer © 2014 IBM Corporation New announcement POWER8 Linux Only Scale-Out Portfolio Red Hat Enterprise Linux 7.1 support little endian on Power Systems and now orderable from IBM Available today. Red Hat Enterprise Virtualization for Power Systems PCIe Gen3 I/O extension drawer– adds up to 10 PCIe Gen3 slots available for clients who want directly attached SSD/disk per VM with minimal VIOS virtualization ( except S824L with GPU installed ) S812L • 8 core fast offering, delivering 16 cores at 4.15 GHz for workloads requiring highest single thread performance S822L • • S824L 67 2 TB of Memory Non GPU acceleration version available • PowerVM support • 8/16 core 4.15 GHz and 24 core 3.52GHz offering, for workload requiring high processor/memory bandwidth • Red Hat, SUSE Linux available © 2014 IBM Corporation Scale-Out POWER8 Linux Support Metrix *w/o GPU 68 ** no EXP24S external disk expansion drawer and no external PCIeGen3 I/O drawer expansion available © 2014 IBM Corporation New Announcement Features Detail 8-core 4.15GHz available for S822 and S822L • • • • S822 : feature code #EPXL; processor entitlement: #EPYL S822L : feature code #ELPF; processor entitlement #ELAF S822 will allow 1 or 2 processors to be ordered. Limitation • High acoustics due to fan speed to cool • Max memory 512GB; 16GB and 32GB DIMM's only • Due to high cooling requirement, the following adapters are not offered to be installed within system CEC, they can only be installed in external I/O drawer: - EJ11, EJ0M, EL60, EL3B - EC32, EL3B - EC2M, EL40 - EC37, EL3X 900W 110V Power supply option available for S814 rack mounted (#EB2L) • • • Allow 900W as initial order and MES for rack mount 41A Allow switching tower to rack without changing power supply Allow switching rack to tower when customer has 900W in rack or by changing 1400W power supply to 900W FDR InfiniBand adapter available for Power Scale-Out server • • • • 71 S812L and S822L – EL3D S814 and S824 – EC33 S822 – EC32 S824L – EL50 © 2014 IBM Corporation SR-IOV 72 © Copyright IBM Corporation 2015 POWER8 SR-IOV NIC Enhancements • History – Announced 2014 on POWER7+ 770/780 with latest levels of firmware and software. Supported newest IMFC card and specific 4-port Ethernet adapters – POWER8 SR-IOV SODs provided 2014 – Announced Feb 2015 for Power E870/E880 in system node (not I/O drawer) for two specific 4-port Ethernet adapters (#EN0J and #EN0L).. • New news: April 2015 – Announcing capability for all POWER8 servers (E850 in May) • Scale-out servers have specific slots which support SR-IOV – Adding support for specific slots in PCIe Gen3 I/O drawer – Adding additional PCIe Ethernet adapter with SR-IOV capability 73 © Copyright IBM Corporation 2015 April 2015 SR-IOV LPAR #1 LPAR #2 In specific SR-IOV capable PCIe slots – Any E870/E880 system node slot – 2 Slots of a 6-slot Fan-out Module – 4 Slots of a Power S814 (1S 4U) or S812L (1S 2U) – 8 Slots of a S824 or S824L (2-socket, 4U) with both sockets populated. If only one socket populated, then is 4 slots. – 7 Slots of a S822 or S822L (2-socket, 2U) with both sockets populated. If only one socket populated, then 4 slots – Any slots Power E850 system unit LPAR #3 • Pre-req:for April SR-IOV enhancements: – – – – – – – – – – – AIX 6.1 TL9 SP5 and APAR IV68443, or later IX 7.1 TL3 SP5 and APAR IV68444, or later IBM i 7.1 TR10, or later IBM i 7.2 TR2, or later Red Hat Enterprise Linux 6.5, or later Red Hat Enterprise Linux 7, or later SUSE Linux Enterprise Server 11 SP3, or later SUSE Linux Enterprise Server 12, or later Ubuntu 15.04, or later VIOS 2.2.3.51, or later Firmware level 8.3 or later Low profile - multi-OS Full high multi-OS Low profile Linux only Full high Linux only PCIe2 4-port (10GbE+1GbE) SR Optical fiber #EN0J * #EN0H #EL38 #EL56 PCIe2 4-port (10GbE+1GbE) copper twinax #EN0L * #EN0K #EL3C #EL57 PCIe2 4-port (10GbE+1GbE) LR Optical fiber #EN0N #EN0M n/a n/a PCIe3 4-port 10GbE SR optical fiber ** #EN16 #EN15 n/a n/a PCIe3 4-port 10GbE copper twinax ** #EN18 #EN17 n/a n/a Specific PCIe adapters * Not truly low profile. Adapter is available in Power E870/E880 system node, but not in 2U server ** SR-IOV announced Feb 2015 for Power E870/E880 system node. Now available in other POWER8 servers. 74 © Copyright IBM Corporation 2015 SR-IOV O. A Technology of Interest LPAR #1 LPAR #2 • Single Root I/O Virtualization LPAR #3 • Runs “closer to the silicon” potentially offering some performance efficiencies • Doesn’t require VIOS as a pre-req and thus can do simple virtualization under PowerVM without VIOS U. BUT U. VIOS continues to offer many additional advanced functions • Architecturally can virtualize a resource like an Ethenet adapter and allocate/provide a user-defined minimum level of bandwidth to a partition U Quality of Service (QoS) – Ethernet NIC announced. FCoE and FC not announced. • Can use VIOS & SR-IOV together 75 © Copyright IBM Corporation 2015 SR-IOV Performance Efficiency • Shared Ethernet Adapter Bridging – Traffic flows between the physical adapter and client partition through the hypervisor and VIOS partition – Within the VIOS the traffic flows between the virtual adapter driver and physical adapter driver through the Shared Ethernet Adapter bridge support. – Latency and CPU utilization overhead VIOS LPAR Shared Ethernet Adapter Bridge Adapter Driver Virtual Adapter Driver LPAR Virtual Adapter Driver LPAR Virtual Adapter Driver Hypervisor VIOS Shared Ethernet Adapter Bridging • Hypervisor copies packets between LPAR and VIOS • VIOS Shared Ethernet Adapter bridge function and adapter drivers LPAR • SR-IOV Direct Access Adapter Sharing – LPAR has direct access to the adapter – Latency and CPU utilization on par with adapter dedicated to an LPAR – HMC/hypervisor configures, but the adapter is the thing which knows it is virtualized 76 Adapter Driver LPAR Adapter Driver SR-IOV Direct Access Adapter Sharing © Copyright IBM Corporation 2015 SR-IOV (Single Root I/O Virtualization) for Ethernet NIC Virtualization with VIOS example • Redundant VIOS with one hardware resource • Minimum amount of bandwidth for Quality of Service (QoS) VIOS - A LPAR #2 QoS Min of y% Gen 2/3 * LPAR #3 VIOS - B 78 • * For specific adapters with SR-IOV capable electronics In PCIe Gen2/3 slots • For specific Integrated Multifunction Cards with SR-IOV capable electronics (770+/780+) • Under latest 7.8 firmware (770+/780+) or later firmware on POWER8 server • With recent OS level software © Copyright IBM Corporation 2015 SR-IOV (Single Root I/O Virtualization) Dual VIOS • Redundant VIOS with redundant hardware resource • Minimum amount of bandwidth for Quality of Service (QoS) QoS QoS SRIOV virtualization + VIOS virtualization Gen 2/3 VIOS - A LPAR #2 SRIOV virtualization + VIOS virtualization Min of y% Gen 2/3 LPAR #3 VIOS - B 79 © Copyright IBM Corporation 2015 Open innovation to put data to work in a waitless world To find out more about how the IBM Power Systems platform can help meet your enterprise innovation needs, visit: www.ibm.com/power © 2014, 2015 International Business Machines Corporation THANKS © 2014, 2015 International Business Machines Corporation 81 CAPI 82 © 2014, 2015 International Business Machines Corporation 82