Family Overview

6,73
0.265
V•I Chip BCM
HV Bus Converter Family
TM
TM
• Efficiency: 95% Typical
–In
+In
PC RSV TM
™ VICOR CORP.
MADE IN USA
• Current sharing: 5%
BCM
22,0
0.87
™
S
RoHS
• Input: HV 270 / 350 / 380 V
C
• Isolation: 4,242 Vdc
3
–Out
2
• Power Density: >1000 W/in
NRTL
US
U.S. PATS. LISTED ON PACKING MATERIALS & DATASHEETS
+Out
• Footprint: 1.1 in
–Out
32,5
1.28
+Out
Actual size
mm
in
Product Description
The HV Bus Converter modules provide an isolated intermediate bus voltage to power non-isolated POL converters. The HV BCMs
offer direct conversion from PFC bus voltage to 12 V POL at up to 300 W with isolation to 4,242 Vdc. The HV family provides
superior performance, the highest efficiency and power density in the smallest package available.
Input
Voltage
(V)
Output
Voltage
(V)
Output
Power
(W)
Output
Current
(A)
Grade
B384F120T30
360 – 400
11.25 – 12.5
300
25.0
Commercial
BCM352F110T300A00
330 – 365
10.3 – 11.4
300
28.0
Commercial
BCM352F125T300A00
330 – 365
11.79 – 13.04
300
26.0
Commercial
BCM352F440T330A00
330 – 365
41.25 – 45.63
325
7.7
Commercial
BCM384F480T325A00
360 – 400
45.0 – 50.0
325
7.0
Commercial
MBCM270F338M235A00
240 – 330
30.0 – 41.25
235
7.3
MIL-COTS
MBCM270F450M270A00
230 – 330
38.3 – 55.0
270
6.25
MIL-COTS
Model
Number*
* Products are also available in through-hole model. See individual data sheets.
LOAD
POL
–Out
US
+Out
–Out
12 V
+Out
U.S. PATS. LISTED ON PACKING MATERIALS & DATASHEETS
S
NRTL
C
RoHS
™
BCM
–In
HV
PC RSV TM
+In
™ VICOR CORP.
MADE IN USA
Typical Applications
vicorpower.com
+Out
–Out
+Out
0.8 – 55 V
LOAD
–Out
US
U.S. PATS. LISTED ON PACKING MATERIALS & DATASHEETS
S
VTM
™
Rev. 1.6
NRTL
C
RoHS
+In
™ VICOR CORP.
MADE IN USA
PC VC TM
–In
US
CD NC OS SG SC VH
+Out
–Out
S
NRTL
C
RoHS
™
PRM
800-735-6200
U.S. PATS. LISTED ON PACKING MATERIALS & DATASHEETS
PR NC IL TM PC VC
™ VICOR CORP.
MADE IN USA
+In
48 V
–In
+Out
–Out
–Out
+Out
™
BCM
U.S. PATS. LISTED ON PACKING MATERIALS & DATASHEETS
US
NRTL
RoHS
C
S
+In
PC RSV TM
–In
HV
™ VICOR CORP.
MADE IN USA
LOAD
1/2011
Page 1 of 2
General Specifications
Parameter
MTBF
MIL-HDBK-217F
Isolation
Voltage
Capacitance
Resistance
Regulatory compliance
Thermal
Over temperature shutdown
Case-to-ambient thermal impedance
Operating junction temperature
Operating junction temperature
Storage temperature
Typ
Unit
Note
3.5
Mhrs
25°C, GB
4,242
500–660
10
cTÜVus
CE Mark
RoHS
Vdc
pF
MΩ
Input to output (basic insulation)
Input to output
Input to output
UL /CSA 60950, EN60950
Low voltage directive
125
3.7
-40 to 125
-55 to 125
-40 to 125
°C
°C / W
°C
°C
°C
minimum, junction temperature
with 0.25” heat sink @ 300 LFM
T–Grade
MIL–COTS
BCM Mechanical Outline Drawing*
Heat Sink Push-Pin Hole Pattern
2.95±0.07
ø
(2) PL
[0.116±0.003]
NON-PLATED
THROUGH HOLE
SEE NOTE 1.
(4.37)
0.172
(11.37)
0.448
(36.50)
1.437
(18.25)
0.719
DOTTED LINE
INDICATES VIC
POSITION
SEE NOTE 3
(7.00)
0.276
BOTTOM VIEW
(2.510)
0.099
(31.48)
1.240
(39.50)
1.555
SEE NOTE 2.
HEAT SINK PUSH-PIN HOLE PATTERN
( TOP SIDE SHOWN )
SEE NOTE 3
RECOMMENDED LAND PATTERN
( COMPONENT SIDE SHOWN )
NOTES:
1. MAINTAIN 3.5/[0.138] DIA. KEEP OUT ZONE FREE OF
COPPER. ALL PCB LAYERS.
2. MINIMUM RECOMMENDED PITCH IS 39.50/[1.555].
THIS PROVIDES 7.00/[0.276] COMPONENT EDGE-TO-EDGE SPACING.
AND 0.50/[0.020] CLEARANCE BETWEEN VICOR HEAT SINKS.
NOTES:
mm
1. DIMENSIONS ARE inch .
2. UNLESS OTHERWISE SPECIFIED, TOLERANCES ARE:
.X / [.XX] = +/-0.25 / [.01]; .XX / [.XXX] = +/-0.13 / [.005]
3. PRODUCT MARKING ON TOP SURFACE
DXF and PDF files are available on vicorpower.com
TOP VIEW ( COMPONENT SIDE )
3. V•I CHIP LAND PATTERN SHOWN FOR REFERENCE ONLY;
ACTUAL LAND PATTERN MAY DIFFER.
DIMENSIONS FROM EDGES OF LAND PATTERN TO PUSH-PIN
HOLES WILL BE THE SAME FOR ALL FULL SIZE V•I CHIPS.
(mm)
4. DIMENSION ARE inch .
* For through–hole mechanical drawing see individual data sheets.
The products described on this data sheet are protected by the following U.S. Patents Numbers: 5,945,130; 6,403,009; 6,710,257; 6,911,848; 6,930,893; 6,934,166; 6,940,013;
6,969,909; 7,038,917; 7,166,898; 7,187,263; 7,361,844; D496,906; D505,114; D506,438; D509,472 and for use under 6,975,098 and 6,984,965
vicorpower.com
800-735-6200
Rev. 1.6
1/2011
Page 2 of 2