KEMET FLLE2150APVR1

FLLE2 … PV
DC EMI Filters for PV Inverters
Overview
This filter series is intended to be used in Photo Voltaic applications between the solar panels and the inverter system. The filters are optimized
in geometry and for power loss. They are also adapted to attenuate high frequency noise that may be degrading life time of the solar panels
and will as well reduce the radiation of EMI noise that may emerge from the panels.
Filters without Y-capacitors to protective earth are available on request.
As the Capacitance Company, KEMET is only using high quality capacitors in its filter series.
Technical specifications
Rated voltage
Rated current
Rated temperature
Temperature range
Climate category
Voltage test
1200 VDC
25 – 1600 A
55°C
-40°C to +100°C
40/100/21
P -> P 3000 VDC
P -> E 3600 VDC
Power loss
@ 25°C/DC
(W)
Weight
(kg)
FLLE2025APVR1
25
8
1
FLLE2050APVR1
50
12
2
FLLE2075APVR1
75
16
2
FLLE2100APVR1
100
20
3
FLLE2150APVR1
150
30
4
FLLE2250APVI1
250
10
5
FLLE2400APVI1
400
15
7
FLLE2600APVI1
600
25
7
FLLE2800APVI1
800
30
10
FLLE21K0APVI1
1000
45
10
FLLE21K6APVI1
1600
70
16
+
+
_
_
PE
PE
INVERTER
Rated current
@ 55°C
(A)
Filter
PV ARRAY
The FLLE2…PV-series is designed according
to IEC/EN 60939 and UL 1283.
Typical insertion loss
dB 100
Sym
Asym
dB 100
Sym
Asym
dB 100
80
80
80
60
60
60
40
40
40
20
20
20
0
0.01
0.1
1
25 to 75 A
10
100
MHz
0
0.01
0.1
1
10
100 and 150 A
100
MHz
0
0.01
Sym
0.1
Asym
1
10
100
MHz
250 to 1600 A
KEMET EMC Filters
1
FLLE2 … PV
DC EMI Filters for PV Inverters
Mechanical dimensions
Z
FLLE2 … PVI1 Busbar connections
L
Z
W
Z
FLLE2 … PVR1 Terminal blocks
L
Z
W
M
U
H
Y
H
X
R3 (x4)
W1 W2
L1
L2
W1
W2
Ø12 (x6)
ØN
L1
Terminal blocks – wire dimensions
25A 16/10mm² solid/flexible
50A 35/25
75A 35/25
100A 50/50
150A 95/95
ØN
K
I
J I
250 to 1000A
Filter
1600 A
Dimensions in mm
L
W
H
L1
FLLE2025APVR1
140
80
65
FLLE2050APVR1
170
95
FLLE2075APVR1
170
95
FLLE2100APVR1
190
FLLE2150APVR1
FLLE2250APVI1
L2
W1
W2
U
X
Y
Z
I
J
K
N
170
45
60
25
M5
80
200
60
75
39
M6
80
200
60
75
39
M6
125
95
220
80
100
45
M8
220
140
115
250
100
120
300
130
110
130
110
155
180
70
5
25
58
15
9
M10
FLLE2400APVI1
300
140
110
130
110
165
190
70
6
25
58
15
10.5
M10
FLLE2600APVI1
300
140
110
130
110
165
190
70
8
40
58
15
10.5
M10
FLLE2800APVI1
300
150
140
130
110
175
200
70
8
40
65
20
14
M12
FLLE21K0APVI1
300
150
140
130
110
175
200
70
8
40
65
20
14
M12
FLLE21K6APVI1
300
150
150
130
110
175
200
70
10
60
100
17
14
M12
50
M
M10
43
26
Legal disclaimer notice
All product specifications, statements, information and data (collectively, the “information”)
are subject to change without notice.
the use of our products is given gratis, and we assume no obligation or liability for the
advice given or results obtained.
All information given herein is believed to be accurate and reliable, but is presented without
guarantee, warranty, or responsibility of any kind, expressed or implied.
Although we design and manufacture our products to the most stringent quality and safety
standards, given the current state of the art, isolated component failures may still occur.
Accordingly, customer applications which require a high degree of reliability or safety should
employ suitable designs or other safeguards (such as installation of protective circuitry or
redundancies) in order to ensure that failure of an electrical component does not result in a
risk of personal injury or property damage.
Statements of suitability for certain applications are based on our knowledge of typical
operating conditions for such applications, but are not intended to constitute – and we
specifically disclaim – any warranty concerning suitability for a specific customer application
or use. This information is intended for use only by customers who have the requisite
experience and capability to determine the correct products for their applications. Any
technical advice inferred from this information or otherwise provided by us with reference to
Although all product-related warnings, cautions and notes must be observed, the customer
should not assume that all safety measures are indicated or that other measures may not
be required
KEMET EMC Filters
2