OSRAM EN55022

OSRAM PLANON ®
Technical Information
Edition: 05/2002 - subject to change
Status: preliminary
PLANON 15,0“/868
Technical Information for Systems:
Lamp
Inverter/ECG
Diffuser Set
PLANON 15,0”/868 2
+
QT PLANON 15,0”/50/24 2
+
D PLANON 15,0”/A
PLANON 15,0”/868 6
+
QT PLANON 15,0”/40/24 6
+
D PLANON 15,0”/A
Explanations/Nomenclature:
Lamp: PLANON lamp diagonal/colour code combinable ECG type(s)
ECG: QT PLANON lamp diagonal/system power/supply voltage ECG type
Product Features PLANON ®
§
flat, mercury free discharge lamp
for extremely flat fixtures < 20 mm
§
lamp size not limited by physical constraints
(5 inch to 30 inch)
§
unique lighting power
wide viewing and illumination angle
constant luminance from centre to edge
§
lamp with integrated reflector
§
mercury free
luminous flux not related to temperature (-30°C to +85°C)
instant light with high luminance
no ramp-on/ramp-off effects (power save mode)
no hazardous waste
§
extreme long lamp life, up to 100,000h
(meantime to half brightness/MTTH)
absence of damage susceptible electrodes
much less severe darkening
§
switching cycles show no influence on lifetime
§
soft illumination with virtually no shadow
§
dimmable down to 20%
15,0“
Product Features QT PLANON
®
§
designed for optimising PLANON lamp performance
§
suitable for applications in which lamps are switched on
and off frequently
§
reliable system start-up at low temperatures
§
safe shutdown of the power supply to defective lamps
§
electromagnetic compatibility
§
dimming interface
Flat Panel Light Sources Marketing 05/2002
Inverter/ECG
24 V DC
Input
Control
interface
OSRAM PLANON ®
Technical Information
Edition : 05/2002 - subject to change
Status: preliminary
PLANON 15,0“/868
Technical Data
lamp
l2
metal plate
(thickness
min. 1mm)
w2
w1
l1
PLANON 15,0"/868 6
PLANON 15,0"/868 2
324 mm x 258 mm x 8,5 mm
324 mm x 258 mm x 8,5 mm
308 mm x 232 mm
308 mm x 232 mm
Weight
950 g
975 g
Colour rendering
Ra86
Ra86
6800 K
6800 K
Outer dimensions (l1 x w1 x h)
Illuminated area (l2 x w2)
Colour temperature
Number of cables
Minimum length of cable
Contact between lamp and inverter/ECG
matched with inverter / ECG
System wattage
4
395 mm
plug
clamps
QT PLANON 15,0"/40/24 6
Centre luminance typical after burn in (100h)
Centre luminance typical after burn in (100h)
with standard diffuser set
Luminous flux
4
420 mm
QT PLANON 15,0"/50/24 2
2
4400 cd/m
5900 cd/m2
3700 cd/m2
5100 cd/m2
900 lm
1250 lm
40 W
56,4 W
1,67 A
2,35 A
System efficiency
7,9 cd/W
7,8 cd/W
System lifetime @ 20% fraction failure
50,000 h
50,000 h
50 cm
50 cm
QT PLANON 15,0"/40/24 6
QT PLANON 15,0"/50/24 2
Line current
Maximum distance between lamp and ECG
h
Inverter
l
Linear dimming range
100...20%
*100...50%
Supply voltage
24V DC
24V DC
Voltage range
20V...30V DC
20V...30V DC
40...80 kHz
40...80 kHz
-20°C...60°C, 80% RH
-20...70°C; 80% RH
tbd
tbd
200 mm x 40 mm x 20 mm
280 mm x 42 mm x 29 mm
Operating frequency
Ambient temperature range ta
Control temperature tc max
Dimensions (l x w x h)
Weight
132 g
*For making use of the dimming capability of this type a separate potentiometer is necessary.
Safety
Radio interference suppression
Immunity to interference
Flat Panel Light Sources Marketing 05/2002
acc. to EN 60950 / EN 60950 (in preparation)
acc. to EN 55022, Class B (in preparation)
acc. to EN 55024 (in preparation)
350 g