NAIS AQW614

PhotoMOS
RELAYS
GU (General Use) Type
[2-Channel (Form A Form B)
Type]
FEATURES
6.4
.252
9.78
.385
3.9±0.2
.154±.008
6.4
.252
9.78
.385
3.6±0.2
.142±.008
mm inch
1
N.C.
8
2
7
3
6
4
5
N.O.
1. Approx. 1/2 the space compared
with the mounting of a set of 1 Form A
and 1 Form B photoMOS relays
2. Applicable for 1 Form A 1 Form B
use as well as two independent 1 Form
A and 1 Form B use
3. Low thermal electromotive force
(Approx. 1 µV)
4. Eliminates the need for a counter
electromotive force protection diode in
the drive circuits on the input side
5. Controls load currents up to 0.13 A
with an input current of 5 mA with load
voltage of 400 V
6. High speed switching: operate time
of 300 µs typical.
7. Eliminates the need for a power supply to drive the power MOSFET
8. Extremely low closed-circuit offset
voltages to enable control of small analog signals without distortion (Typical
100 pA at 400 V)
9. Stable on resistance
TYPICAL APPLICATIONS
• High-speed inspection machines
• Telephone equipment
• Computer
TYPES
Output rating*
Type
AC/DC type
Part No.
Through hole terminal
Load
voltage
Load
current
400 V
100 mA
Packing quantity
Surface-mount terminal
Tape and reel packing style
Picked from the
Picked from the
1/2/3-pin side
4/5/6-pin side
Tube packing style
AQW614
AQW614A
AQW614AX
AQW614AZ
Tube
Tape and reel
1 tube contains
40 pcs.
1 batch contains
400 pcs.
1,000 pcs.
*Indicate the peak AC and DC values.
Note: For space reasons, the package type indicator "X" and "Z" are omitted from the seal.
RATINGS
1. Absolute maximum ratings (Ambient temperature: 25°C 77°F)
Symbol
IF
VR
IFP
Pin
VL
AQW614(A)
50 mA
3V
1A
75 mW
400 V
IL
0.1 A (0.13 A)
Peak load current
Power dissipation
Total power dissipation
Ipeak
Pout
PT
0.3 A
800 mW
850 mW
I/O isolation voltage
Viso
1,500 V AC
Topr
Tstg
–40°C to +85°C –40°F to +185°F
–40°C to +100°C –40°F to +212°F
Input
Output
Temperature limits
78
Item
LED forward current
LED reverse voltage
Peak forward current
Power dissipation
Load voltage
Continuous load current
Operating
Storage
Remarks
f = 100 Hz, Duty factor = 0.1%
Peak AC, DC
( ): in case of using only 1a or 1b,
1 channel
100 ms (1 shot), VL = DC
Between input and output/between
contact sets
Non-condensing at low temperatures
AQW614
2. Electrical characteristics (Ambient temperature: 25°C 77°F)
Item
Symbol
LED operate (OFF) current
Input
LED reverse (ON) current
LED dropout voltage
On resistance
Typical
Maximum
Minimum
Typical
Typical
Maximum
Typical
AQW614
0.7 mA (N.O.) 0.9 mA (N.C.)
3 mA
0.4 mA
0.7 mA (N.O.) 0.8 mA (N.C.)
1.14 V (1.25 V at IF = 50 mA)
1.5 V
27 Ω
IFon (N.O.)
IFoff (N.C.)
IFoff (N.O.)
IFon (N.C.)
VF
Ron
50 Ω
Maximum
ILeak
1 µA
Typical
Maximum
Typical
Maximum
Typical
Maximum
Minimum
Ton (N.O.)
Toff (N.C.)
0.28 ms (N.O.) 0.43 ms (N.C.)
1 ms
0.04 ms (N.O.) 0.3 ms (N.C.)
1 ms
0.8 pF
1.5 pF
1,000 MΩ
Maximum
Condition
IL = 100 mA
IL = 100 mA
IF = 5 mA
IF = 5 mA (N.O.)
IF = 0 mA (N.C.)
IL = 100 mA
within 1 s on time
IF = 0 mA (N.O.)
IF = 5 mA (N.C.)
VL = 400 V
Output
Off state leakage current
Operate (OFF) time*
Transfer
characteristics
Reverse (ON) time*
I/O capacitance
Initial I/O isolation resistance
Toff (N.O.)
Ton (N.C.)
Ciso
Riso
Note: Recommendable LED forward current IF = 5 mA.
IF = 0 mA ➝ 5 mA
IL = 100 mA
IF = 5 mA ➝ 0 mA
IL = 100 mA
f = 1 MHz
VB = 0
500 V DC
For type of connection, see page 32.
*Operate/Reverse time
1) N.O.
2) N.C.
Input
Input
90%
Output
Output
10%
Ton
10%
90%
Toff
Toff
Ton
REFERENCE DATA
1. Load current vs. ambient temperature characteristics
2. On resistance vs. ambient temperature characteristics
3. Operate (OFF) time vs. ambient temperature
characteristics
Allowable ambient temperature: –40°C to +85°C
–40°F to +185°F
Measured portion: between terminals 5 and 6, 7 and 8;
LED current: 5 mA; Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC)
LED current: 5 mA;
Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC)
1.2
60
120
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
On resistance, Ω
Load current, mA
80
60
40
30
40
20
20
10
0
–40
–20
0
20
40
60 8085 100
Ambient temperature, °C
Operate (OFF) time, ms
50
100
0
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
1.0
0.8
0.6
0.4
0.2
–40
–20
0
20
40
60
8085
Ambient temperature, °C
0
–40
–20
0
20
40
60 8085
Ambient temperature, °C
79
AQW614
4. Reverse (ON) time vs. ambient temperature
characteristics
5. LED operate (OFF) current vs. ambient temperature characteristics
6. LED reverse (ON) current vs. ambient temperature characteristics
LED current: 5 mA; Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC)
Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC)
Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC)
1.2
0.8
0.6
0.4
0.2
5
4
3
2
–40
–20
0
20
40
60
0
8085
–40
–20
Ambient temperature, °C
8. Voltage vs. current characteristics of output
at MOS portion
LED current: 5 to 50 mA
Measured portion: between terminals 5 and 6, 7 and 8;
Ambient temperature: 25°C 77°F
Current, mA
LED dropout voltage, V
1.5
1.4
1.3
Between terminal
7 and 8
100 (N.C.)
80
60
Between terminal
5 and 6 (N.O.)
40
20
–5 –4 –3 –2 –1
1 2 3 4 5
–20
Voltage, V
–40
50mA
30mA
20mA
10mA
5mA
1.1
4
3
2
0
0
20
40
60 8085
Ambient temperature, °C
7. LED dropout voltage vs. ambient temperature characteristics
1.2
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
5
1
1
–40
–20
0
20
40
60
8085
Ambient temperature, °C
9. Off state leakage current
Measured portion: between terminals 5 and 6, 7 and 8;
Ambient temperature: 25°C 77°F
Off state leakage current, A
0
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
LED reverse (NO) current, mA
1.0
6
6
LED operate (OFF) current, mA
Reverse (ON) time, ms
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
10 –3
10 –6
Between terminal 7 and 8 (N.C.)
10 –9
–60
–80
1.0
Between terminal 5 and 6 (N.O.)
–100
0
–40
–20
10
0
20
40
60
8085
Ambient temperature, °C
–12
20
0
40
60
80
100
Load voltage, V
10. LED forward current vs. operate (OFF) time
characteristics
11. LED forward current vs. reverse (ON) time
characteristics
12. Applied voltage vs. output capacitance
characteristics
Measured portion: between terminals 5 and 6, 7 and 8;
Load voltage: 400 V (DC); Continuous load current:
100 mA (DC); Ambient temperature: 25°C 77°F
Measured portion: between terminals 5 and 6, 7 and 8;
Load voltage: 400 V (DC); Continuous load current:
100 mA (DC); Ambient temperature: 25°C 77°F
Measured portion: between terminals 5 and 6, 7 and 8;
Frequency: 1 MHz;
Ambient temperature: 25°C 77°F
3.0
120
Reverse (ON) time, ms
Operate (OFF) time, ms
2.5
2.0
1.5
1.0
0.5
0
5/7/2001
80
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
0.5
0.4
0.3
0.2
20
30
40
50
LED forward current, mA
60
0
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
100
80
60
40
20
0.1
10
Output capacitance, pF
0.6
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
10
20
30
40
50
LED forward current, mA
60
0
10
20
30
40
50
Applied voltage, V
60
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.