MURATA CPCI420D-1C

ccPCI420 SERIES
420W
42
20W 6Ux8HP
6Ux88HP DC/DC
DC/D
DC CompactPCI™
C
Power Supply
OBSOLETE PRODUCT
SELECTION
SELE
ECTION GUIDEE
Contact Factory for Replacement Model
Model
Mode
el Number
Currrent
Output Current
Pow
Power
wer
5V
CPCI420D-1
CPCI420D-1C
3.3V
3 3V
3V
Production
P
Status
12V
12V
2V
-12V
12V
420W
50A1
40A1
12A
2A
Consult Factory
No
420W
1
1
12A
2A
Active
Yes
50A
40A
INPUT CHARACTERISTICS
Parameter
Conditions
Min
Typ
Max
Units
Input Operating Voltage
36
72
Vdc
Input Voltage Withstand
34
75
Vdc
Inrush Current
36Vdc input
8
Apk
72Vdc input
16
Apk
FEATURES
6Ux8HP package
420W power at 0-50ºC
OUTPUT CHARACTERISTICS
PICMG 2.11 Compliant
Output
Nominal Voltage
Widerange 36-72VDC Input Range
V1
+5.0Vdc
Output Current
Total Regulation2
Min
Max
0A
50A1
+4/-2%
1
PCI Voltage Architecture
V2
+3.3Vdc
0A
40A
+4/-2%
47-pin I/O Connector
V3
+12Vdc
0A
12A
±4%
V4
-12Vdc
0A
2A
±4%
Parameter
Conditions
Min
Typ
Output Voltage Adjustment
V1 & V2 only
No minimum load
Hot-swap capable
Temperature Coefficient
DESCRIPTION
The cPCI420 is a high-reliability, 420W, 6Ux8HP
CompactPCI™ power supply operating from widerange
48Vdc-input. Equipped with the 47-pin I/O connector
option, these units are fully compliant with the PICMG
2.11 R1.0 Power Interface Specification as well as the
underlying CompactPCI™ standards.
ORing diodes and active current sharing allow the
cPCI420 to be operated in N+n parallel-redundant
configurations to support high-availability (HA) telecom
applications.
With a wide-range input of 36-72Vdc, safety agency
approvals to UL1950 and EN60950, EMI compliance
to ETSI and Telcordia standards, the cPCI420 was
designed with globally-deployed systems in mind.
Additional features include remote sense compensation,
unit enable control (EN#), output inhibit control (INH#),
output fault signal (FAL#), and thermal warning signal
(DEG#). LEDs are provided for visual indication of input
power presence and output fault condition.
The proven design and complement of global safety
agency approvals provide for an advanced power
solution for your telecom CompactPCI requirements.
PARD (V1 & V2)
20MHz bandwidth
PARD (V3 & V4)
20MHz bandwidth
Output Power
Transient Response
Over-Voltage Protection3
50ºC, 400lfm airflow
0
70ºC, 400lfm airflow
0
Current Share Tolerance
Notes:
%Vnom
0.02
%/ºC
50
mVp-p
120
mVp-p
420
W
175
W
±8
%Vnom
Settling time
500
μsec
Output V1 (+5.0V)
5.5
6.0
6.5
V
Output V2 (+3.3V)
3.8
4.3
4.8
V
V
Output V3 (+12V)
13.0
13.5
14.0
Output V4 (-12V)
-14.0
-13.5
-13.0
0
V1, V2, & V3
mV
±10
V4, full load
V
A
500
V1-V3; full load
Pri-Sec
Isolation
Units
ΔV, 50% load step
Minimum Load
Remote Sense Compensation
Max
±5
±40
%Itot
%Itot
4
kVac
Pri-Chassis
1.5
kVac
Sec-Chassis
500
Vac
1. Combined currents from outputs V1 & V2 not to exceed 50A total.
2. Total regulation includes line, load, and cross regulation.
3. Response to an OVP fault is a latching shutdown,
restart of the unit requires cycling of the input power.
4. May not be in regulation.
www.cd4power.com
cPCI420 Series
RevA 02/2006
Page 1 of 4
cPCI420 SERIES
420W 6Ux8HP DC/DC CompactPCI™ Power Supply
GENERAL CHARACTERISTICS
Parameter
Conditions
Efficiency
48Vdc input, 420W load
MTBF
Weight
Min
Typ
Max
68
Units
%
Calculated per MIL-HDBK-217F, 25ºC ambient, ground benign
374
khrs
Calculated per MIL-HDBK-217F, 50ºC ambient, ground benign
174
khrs
Unpackaged
0.7
Kg
PROTECTION
Inception
Parameter
Conditions/Response
Thermal Shutdown
Automatic recovery upon restoration to operational temperatures
Input Protection
Internal line fuse, Littlefuse 314020 or equivalent (fast-acting 3AB)
Over-voltage Protection
All outputs
Parameter
Conditions/Response
Output Overload Protection
Outputs are individually protected against overloads and indefinite short circuit with automatic recovery upon removal of the
fault condition. Overload response for all outputs is hiccup mode.
Hot-Swap Capability
Design Verification Testing (DVT) confirms that voltage excursions on the output buses resulting from insertion/extraction
events do not exceed the specified maximum of 8%. However, routing of power and signal lines in the mating backplane is
critical to minimization of such excursions. In addition, performance can be critically affected by load characteristics including
resistance, negative resistance, and reactive components. While the control loop responses have been designed for optimum
hot-swap performance over a wide range of characteristics, there may be instances where the voltage excursions exceed
published specifications. In such cases, the control loop responses can be modified to perform optimally.
Output Fault Isolation
Output isolation devices are present in all outputs to isolate faults within a failed power supply.
Min
Typ
Max
90
110
125
Units
ºC
20
A
145
%Vnom
STATUS & CONTROL SIGNALS & INDICATORS
Name
Description
Enable (EN#)
Short pin (#27) on connector will enable the outputs when the mating pin is grounded. Supply will not power up until this pin is engaged to
its mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating connector.
Output Inhibit (INH#)
Secondary referenced; active low, TTL compatible. Logic “0” or short circuit to output return inhibits all outputs.
Output Fault (FAL#)
Secondary referenced. Open collector signal denotes that one of the output voltages has fallen below the lower regulation limit.
Remote Sense (RS+, RS-)
Connection of the sense leads across the load at the desired point of regulation will compensate for voltage distribution drops up to 500mV
between the output terminals of the power supply and the point of connection. The unit reverts to local sensing if the sense lines are opened
for any reason. The output is protected against shorted or open leads. Applies to outputs V1-V3.
Thermal Warning (DEG#)
Secondary referenced; TTL compatible. Open collector denotes a thermal warning; nominally, 10ºC prior to thermal shutdown.
Fault Indicator LED
An LED will illuminate red if the output voltages are not within specification, coincident with assertion of the FAL# signal.
Power Present Indicator LED
A green LED will be illuminated when the input voltage is present and above the minimum requirement.
ENVIRONMENTAL CHARACTERISTICS
Parameter
Conditions
Max
Units
AmbientOperatingTemperature
De-rate output power linearly above 50ºC to 420W at 70ºC with 400lfm airflow. See the de-rating
chart on page 4 for additional data.
0
70
ºC
-20
85
ºC
Operating; non-condensing
10
90
%
Storage; non-condensing
5
90
%
Operating. De-rate operating ambient temperature by 2Cº per 1000ft above 5000ft.
-200
10000
ft
Storage
-200
50000
ft
See de-rating chart on page 4 for additional data on cooling.
400
Ambient Storage Temperature
Humidity
Altitude
Airflow
www.cd4power.com
Min
cPCI420 Series
Typ
lfm
RevA 02/2006
Page 2 of 4
cPCI420 SERIES
420W 6Ux8HP DC/DC CompactPCI™ Power Supply
ELECTROMAGNETIC COMPATIBILITY (EMC)
Characteristic
Compliance
Conducted Emissions
NEBS GR-1089
CERTIFICATIONS
Agency/Characteristic
Standard
UL
UL1950
CSA
CSA950 (per cUL)
VDE
EN60950
CE
LVD Directive; self-certified
EN Directive 2002/95/EC; self-certified; see Selection Guide table for specific model compliance
RoHS
SELV
Self-certified
Vibration
MIL-STD-810D, Method 514.3, Procedure I; self-certified
Shock
MIL-STD-810D, Method 516.3, Procedure I; self-certified
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
All measurements are in inches.
Weight: 0.7kg
Shock: MIL-STD-810d, Method 516.3, Procedure 1.
Vibration: MIL-STD-810d, Method 514.3, Procedure 1.
Dimensions; 6U x 8 HP x 160mm.
SAFETY AGENCY RATINGS
Input Voltage
48Vdc
Input Current
15Adc
Input Power
650W
www.cd4power.com
cPCI420 Series
RevA 02/2006
Page 3 of 4
cPCI420 SERIES
420W 6Ux8HP DC/DC CompactPCI™ Power Supply
PACKAGE SPECIFICATIONS (Continued)
CONNECTORS
Pin #1
Staging
Signal Name
Description
1-4
M
V1
V1 Output
V1 and V2 Return
5-12
M
RTN
13-18
M
V2
V2 Output
19
M
RTN
V3 Return
20
M
V3
V3 Output
21
M
V4
V4 Output
22
M
RTN
Signal Return
23
M
RESERVED3
Sync Start
24
M
RTN
V4 Return
25
M
GA04
Geographic Address Bit 0
26
M
RESERVED
Reserved
27
S
EN#
Enable
28
M
GA14
Geographic Address Bit 1
4
29
M
V1ADJ
V1 Adjust
30
M
V1 SENSE
V1 Remote Sense
31
M
GA24
Geographic Address Bit 2
32
M
V2ADJ4
V2 Adjust
33
M
V2 SENSE
V2 Remote Sense
34
M
S RTN
Sense Return
35
M
V1 SHARE
V1 Current Share
36
M
V3 SENSE
V3 Remote Sense
37
M
IPMB SCL4
Serial Communication Receive; Clock
38
M
DEG#
Degrade Signal
39
M
INH#
Inhibit
4
40
M
IPMB SDA
Serial Communication Transmit; Data
41
M
V2 SHARE
V2 Current Share
42
M
FAL#
Fail Signal
43
M
IPMB PWR4
System Management Power
44
M
V3 SHARE
V3 Current Share
Notes:
1. Pin numbers correspond to the female backplane connector.
45
L
CGND
Chassis Ground (safety ground)
2. L = Long Length Pin (First Make, Last Break); M = Medium Length Pins; S = Short
Length Pins (Last Make, First Break).
46
M
ACN/+DC IN
AC Input Neutral / +DC Input
47
M
ACL/-DC IN
AC Input Line / -DC Input
3. PICMG™ 2.11 has reserved Pin 23 for future designation -- the cPCI420 uses this pin for
synchronous start, required when N>1 for N+1 redundant configurations.
4. This function not available in the cPCI420DC.
ISO9001
CERTIFIED
C&D Technologies, Inc. reserve the right to alter or improve the specification, internal design or
manufacturing process at any time, without notice. Please check with your supplier or visit our
website to ensure that you have the current and complete specification for your product before use.
C&D Technologies
3400 E Britannia Drive, Tucson,
Arizona 85706, USA
© C&D Technologies, Inc. 2006
Tel: +1 (800) 547-2537
No part of this publication may be copied, transmitted or stored in a retrieval system or reproduced in any Fax: +1 (520) 295-4197
way including, but not limited to, photography, photocopy, magnetic or other recording means, without prior email: [email protected]
written permission from C&D Technologies, Inc. Instructions for use are available from www.cd4power.com
www.cd4power.com
C&D Technologies (NCL) Ltd
C&D Technologies
11 Cabot Boulevard, Mansfield, Tanners Drive, Blakelands North
Milton Keynes MK14 5BU, UK
MA 02048-1151, USA
Tel: +1 (508) 339-3000
Fax: +1 (800) 233-2765
email: [email protected]
cPCI420 Series
Tel: +44 (0)1908 615232
Fax: +44 (0)1908 617545
email: [email protected]
RevA 02/2006