Operating instructions OT DMX 9x2 A DIM SO

Description
Purpose and application
The 9-channel dimmer OT DMX 9x2A DIM SO is used for
connecting constant voltage LED luminaires or modules and enables the user to create homogeneous colour moods, simulate
daylight and create dynamic lighting effects in combination with
appropriate DMX control units and user interfaces.
OT DMX 9x2A DIM SO
Function
The connection of the dimmer to a DMX network control unit
and the assignment of DMX addresses make it possible to
individually control the nine pulse-width modulated (PWM) LED
outputs (channels).
K
Design
The dimmer is made up of the following components:
3/7 DMX GND
J
3/7 DMX GND
DMX GND
10-24 VDC
9-channel dimmer
Operating instructions
DMX GND
H
A
• “DMX Out”/”DMX In” RJ45 connections for DMX signal
output (A) and input (B)
B
• Ground for DMX output (C)
C
D
E
F
• Ground for DMX input (E)
• Screw terminals for DMX signal output (D) and input (F)
• “status” / “DMX” LEDs (G)
• Screw terminals for connecting the power supply (H)
• Screw terminals for connecting the LED luminaires (J)
• Switch for manually setting the DMX addresses (K)
G
LED display
The integrated LEDs indicate the state of the power supply and
DMX communication:
Installation
LED
"status" (yellow)
"DMX" (green)
OFF/
flickers
Power supply not
connected
No DMX connection/
No DMX signal detected
ON
Normal operation
DMX signal detected
Flashes
Overcurrent on at least
1 LED output
–
Safety instructions
The dimmer must only be installed and put into operation by
a qualified electrician. The applicable safety regulations and
accident prevention regulations must be observed.
CAUTION!
Destruction of the dimmer and other devices
through incorrect mounting!
L
• Ensure that the power supply corresponds to the
input voltage of the connected LEDs: 10 V for
10-V LEDs, 24 V for 24-V LEDs
• Ensure that the connecting lines of the power
supply are sized to conduct the total current
required for the LED luminaires.
• Do not exceed a max. input current of 14 A.
• Note the device labelling.
10-24V DC
10-24 VDC
M
Connecting the power supply and LED
luminaires/modules
A power supply unit is needed for the dimmer and LED luminaires. Follow the safety instructions.
The LED outputs are protected against short circuits. The
affected output is switched off in the event of overcurrent or a
short circuit.
N
LAlternative 1
(reverse polarity protection for LED luminaires and dimmers).
XII 2009
OT-DMX-9x2A-DIM_ba0912en_we1.01.indd
M Power supply unit
OSRAM GmbH
Kunden Service Center
Customer-Service-Center (CSC)
Steinerne Furt 62
86167 Augsburg
Germany
Tel.: +49 (0) 1803 677 - 200
(kostenpflichtig / charges apply)
Fax.: +49 (0) 1803 677 - 202
www.osram.com
40083215333024
4008321533302
M
10-24V DC
10-24 VDC
www.osram.de
NAlternative 2 (without reverse polarity protection)
Page 1 of 2
Installation (cont.)
Connecting the DMX components
Either the RJ45 connectors or the screw terminals can be
used for the DMX connection. The corresponding contacts are
interconnected internally.
CAUTION!
Destruction of the dimmer and other devices through
incorrect mounting!
• Do not connect the RJ45 and screw terminals
simultaneously.
• DMX input and output ground are not interconnected.
Control unit: “DMX In” (B or F)
Optionally, up to 32 dimmers (depending on cable length and
cable quality) can be connected in a row:
“DMX Out” (A or D) with “DMX In” (B or F) of the next dimmer
in each case.
RJ45 pin assignment:
• Pin 1: DMX –
• Pin 2: DMX +
• Pin 3/7: DMX GND
Operation
Setting the DMX addresses
To be able to individually control the nine LED outputs in a
DMX network, the dimmer is assigned nine consecutive DMX
addresses (default setting: 1 to 9), depending on the particular
application. Follow the operating instructions of the control unit.
Alternative 1: setting the DMX addresses manually
The DMX address for LED output 1 (=DMX start address) can
be set manually (default setting = 1) via the switch (K). The
following DMX addresses are automatically assigned to LED
outputs 2 to 9 (default setting: 2 to 9).
Set the “manual addressing” switch to ON.
‚Set the required switches (“1”, “2”, … “256”) to ON.
The sum of the switches set to ON results in the DMX start
address.
For example: switches “2”, “4” and “16” are set to ON à DMX
start address = 22
Alternative 2: automatic assignment
The DMX addresses of all dimmers connected in a row are
assigned automatically (dimmer 1 = 1 to 9; dimmer 2 = 10 to
18; etc.)
Reset the DMX start address of all dimmers to 1; see below.
‚Set the “manual addressing” switch to OFF.
ƒAssign the DMX addresses; see the control unit operating
instructions.
Reset the DMX start address to 1
Set all switches (“1”, “2”, … “256”) to OFF.
45,5 / 1.79
Appendix
Technical data
76 / 2.99
107 / 4.21
58,4 / 2.3
Operating voltage
10 - 24 V DC
Output current per channel
2 A
Output load range per channel
0 … 20 W at 10 V DC
0 … 48 W at 24 V DC
Max. output capacity
1 µF
Max. input current for power supply
14 A
Frequency of pulse width modulation
488 Hz
Resolution of pulse width modulation
14 bit
DMX protocol
DMX512-A standard
(isolated DMX output)
Max. line cross-section
(for connecting ­power supply and
LED outputs)
1,5 mm²
(for LED outputs)
Operating temperature
0 °C … +50 °C
Protection type
IP 20
Weight
0.230 kg
Dimensions (L x W x H)
107 x 76 x 59 mm
2,5 mm²
(for power supply)
The CE requirements as per EN 55020, EN 55024 and
EN 60950 are fulfilled.
Conformity with the relevant EU directives is
confirmed by the CE symbol.
Page 2 of 2