IDT IDT82V2058DABLANK

OCTAL E1 SHORT HAUL
LINE INTERFACE UNIT
IDT82V2058
FEATURES
‹
‹
‹
‹
‹
‹
‹
‹
Fully integrated octal E1 short haul line interface which
supports 120 Ω E1 twisted pair and 75 Ω E1 coaxial
applications
Selectable Single Rail mode or Dual Rail mode and AMI or
HDB3 encoder/decoder
Built-in transmit pre-equalization meets G.703
Selectable transmit/receive jitter attenuator meets ETSI CTR12/
13, ITU G.736, G.742 and G.823 specifications
SONET/SDH optimized jitter attenuator meets ITU G.783
mapping jitter specification
Digital/Analog LOS detector meets ITU G.775 and ETS 300 233
ITU G.772 non-intrusive monitoring for in-service testing for
any one of channel 1 to channel 7
‹
‹
‹
‹
‹
‹
‹
‹
Low impedance transmit drivers with high-Z
Selectable hardware and parallel/serial host interface
Local and Remote Loopback test functions
Hitless Protection Switching (HPS) for 1 to 1 protection without
relays
JTAG boundary scan for board test
3.3 V supply with 5 V tolerant I/O
Low power consumption
Operating temperature range: -40°C to +85°C
Available in 144-pin Thin Quad Flat Pack (TQFP) and 160-pin
Plastic Ball Grid Array (PBGA) packages
Green package options available
FUNCTIONAL BLOCK DIAGRAM
One of Eight Identical Channels
LOS
Detector
RTIPn
Slicer
RRINGn
Analog
Loopback
Peak
Detector
TTIPn
CLK&Data
Recovery
(DPLL)
Jitter
Attenuator
Jitter
Attenuator
Waveform
Shaper
RCLKn
RDn/RDPn
CVn/RDNn
HDB3/AMI
Decoder
Remote
Loopback
Digital
Loopback
Line
Driver
TRINGn
LOSn
AIS
Detector
TCLKn
TDn/TDPn
BPVIn/TDNn
HDB3/AMI
Encoder
Transmit
All Ones
JTAG TAP
VDD IO
VDDT
VDDD
VDDA
TRST
TCK
TMS
TDI
TDO
Control Interface
OE
CLKE
MODE[2:0]
CS/JAS
SCLK/ALE/AS
RD/R/W
SDI/WR/DS
SDO/RDY/ACK
INT
LP[7:0]/D[7:0]/AD[7:0]
MC[3:0]/A[4:0]
Register
File
Clock
Generator
MCLK
G.772
Monitor
Figure-1 Block Diagram
January 21, 2010
IDT and the IDT logo are trademarks of Integrated Device Technology, Inc.
1
 2010- Integrated Device Technology, Inc.
DSC-6038/12
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
DESCRIPTION
The IDT82V2058 offers hardware control mode and software control
mode. Software control mode works with either serial host interface or
parallel host interface. The latter works via an Intel/Motorola compatible
8-bit parallel interface for both multiplexed or non-multiplexed applications. Hardware control mode uses multiplexed pins to select different
operation modes when the host interface is not available to the device.
The IDT82V2058 is a single chip, 8-channel E1 short haul PCM
transceiver with a reference clock of 2.048 MHz. The IDT82V2058
contains 8 transmitters and 8 receivers.
All the receivers and transmitters can be programmed to work either
in Single Rail mode or Dual Rail mode. HDB3 or AMI encoder/decoder is
selectable in Single Rail mode. Pre-encoded transmit data in NRZ
format can be accepted when the device is configured in Dual Rail
mode. The receivers perform clock and data recovery by using integrated digital phase-locked loop. As an option, the raw sliced data (no
retiming) can be output on the receive data pins. Transmit equalization is
implemented with low-impedance output drivers that provide shaped
waveforms to the transformer, guaranteeing template conformance.
The IDT82V2058 also provides loopback and JTAG boundary scan
testing functions. Using the integrated monitoring function, the
IDT82V2058 can be configured as a 7-channel transceiver with nonintrusive protected monitoring points.
The IDT82V2058 can be used for SDH/SONET multiplexers, central
office or PBX, digital access cross connects, digital radio base stations,
remote wireless modules and microwave transmission systems.
A jitter attenuator is integrated in the IDT82V2058 and can be
switched into either the transmit path or the receive path for all channels.
The jitter attenuation performance meets ETSI CTR12/13, ITU G.736,
G.742 and G.823 specifications.
IDT82V2058
(Top View)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
TD7/TDP7
TCLK7
LOS6
CV6/RDN6
RD6/RDP6
RCLK6
BPVI6/TDN6
TD6/TDP6
TCLK6
MCLK
MODE2
A4
MC3/A3
MC2/A2
MC1/A1
MC0/A0
VDDIO
GNDIO
VDDD
GNDD
LP0/D0/AD0
LP1/D1/AD1
LP2/D2/AD2
LP3/D3/AD3
LP4/D4/AD4
LP5/D5/AD5
LP6/D6/AD6
LP7/D7/AD7
TCLK1
TD1/TDP1
BPVI1/TDN1
RCLK1
RD1/RDP1
CV1/RDN1
LOS1
TCLK0
BPVI4/TDN4
RCLK4
RD4/RDP4
CV4/RDN4
LOS4
OE
CLKE
VDDT4
TTIP4
TRING4
GNDT4
RTIP4
RRING4
GNDT5
TRING5
TTIP5
VDDT5
RRING5
RTIP5
VDDT6
TTIP6
TRING6
GNDT6
RTIP6
RRING6
GNDT7
TRING7
TTIP7
VDDT7
RRING7
RTIP7
LOS7
CV7/RDN7
RD7/RDP7
RCLK7
BPVI7/TDN7
108
107
106
105
104
103
102
101
100
99
98
97
96
95
94
93
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
77
76
75
74
73
TD4/TDP4
TCLK4
LOS5
CV5/RDN5
RD5/RDP5
RCLK5
BPVI5/TDN5
TD5/TDP5
TCLK5
TDI
TDO
TCK
TMS
TRST
IC
IC
VDDIO
GNDIO
VDDA
GNDA
MODE0/CODE
CS/JAS
SCLK/ALE/AS
RD/R/W
SDI/WR/DS
SDO/RDY/ACK
INT
TCLK2
TD2/TDP2
BPVI2/TDN2
RCLK2
RD2/RDP2
CV2/RDN2
LOS2
TCLK3
TD3/TDP3
PIN CONFIGURATIONS
Figure-2 TQFP144 Package Pin Assignment
2
72
71
70
69
68
67
66
65
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
BPVI3/TDN3
RCLK3
RD3/RDP3
CV3/RDN3
LOS3
RTIP3
RRING3
VDDT3
TTIP3
TRING3
GNDT3
RRING2
RTIP2
GNDT2
TRING2
TTIP2
VDDT2
RTIP1
RRING1
VDDT1
TTIP1
TRING1
GNDT1
RRING0
RTIP0
GNDT0
TRING0
TTIP0
VDDT0
MODE1
LOS0
CV0/RDN0
RD0/RDP0
RCLK0
BPVI0/TDN0
TD0/TDP0
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
D
E
F
INDUSTRIAL TEMPERATURE RANGES
A
B
C
G
H
J
K
L
M
N
P
1
RCLK
7
TCLK
7
RCLK
6
TCLK
MCLK
6
MC
1
LP
6
LP
7
TCLK
1
RCLK
1
TCLK
0
RCLK
0
1
2
RDP
7
TDP
7
RDP
6
TDP
6
MODE
2
MC
2
LP
0
LP
2
LP
5
MODE
1
TDP
1
RDP
1
TDP
0
RDP
0
2
3
RDN
7
TDN
7
RDN
6
TDN
6
LOS
6
MC
3
MC
0
LP
1
LP
4
LOS
1
TDN
1
RDN
1
TDN
0
RDN
0
3
4
VDDT
7
VDDT
7
VDDT
6
VDDT
6
LOS
7
A4
LP
3
LOS
0
VDDT
1
VDDT
1
VDDT
0
VDDT
0
4
5
TRING
7
TTIP
7
TRING
6
TTIP
6
TTIP
1
TRING
1
TTIP
0
TRING
0
5
6
GNDT GNDT GNDT GNDT
7
7
6
6
GNDT GNDT GNDT GNDT
1
1
0
0
6
7
RTIP
7
RRING
7
RTIP
6
RRING
6
RRING
1
RTIP
1
RRING
0
RTIP
0
7
8
RTIP
4
RRING
4
RTIP
5
RRING
5
RRING
2
RTIP
2
RRING
3
RTIP
3
8
9
GNDT GNDT GNDT GNDT
4
4
5
5
GNDT GNDT GNDT GNDT
2
2
3
3
9
10
TRING
4
TTIP
4
TRING
5
TTIP
5
TTIP
2
TRING
2
TTIP
3
TRING
3
10
11
VDDT
4
VDDT
4
VDDT
5
VDDT
5
LOS
4
TMS
GNDIO GNDA
LOS
3
VDDT
2
VDDT
2
VDDT
3
VDDT
3
11
12
RDN
4
TDN
4
RDN
5
TDN
5
LOS
5
TDI
TRST
LOS
2
TDN
2
RDN
2
TDN
3
RDN
3
12
13
RDP
4
TDP
4
RDP
5
TDP
5
CLKE
TDO
IC
RD
INT
TDP
2
RDP
2
TDP
3
RDP
3
13
14
RCLK
4
TCLK
4
RCLK
5
TCLK
5
OE
TCK
SDI
SDO
TCLK
2
RCLK
2
TCLK
3
RCLK
3
14
A
B
C
D
E
F
J
K
L
M
N
P
VDDIO VDDD
GNDIO GNDD
IDT82V2058
(Bottom View)
CS
MODE
SCLK
0
IC
VDDIO VDDA
G
H
Figure-3 PBGA160 Package Pin Assignment
3
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
1
INDUSTRIAL TEMPERATURE RANGES
PIN DESCRIPTION
Table-1 Pin Description
Name
Type
Pin No.
TQFP144
Description
PBGA160
Transmit and Receive Line Interface
TTIP0
TTIP1
TTIP2
TTIP3
TTIP4
TTIP5
TTIP6
TTIP7
TRING0
TRING1
TRING2
TRING3
TRING4
TRING5
TRING6
TRING7
RTIP0
RTIP1
RTIP2
RTIP3
RTIP4
RTIP5
RTIP6
RTIP7
RRING0
RRING1
RRING2
RRING3
RRING4
RRING5
RRING6
RRING7
Analog
Output
Analog
Input
45
52
57
64
117
124
129
136
N5
L5
L10
N10
B10
D10
D5
B5
46
51
58
63
118
123
130
135
P5
M5
M10
P10
A10
C10
C5
A5
48
55
60
67
120
127
132
139
P7
M7
M8
P8
A8
C8
C7
A7
49
54
61
66
121
126
133
138
N7
L7
L8
N8
B8
D8
D7
B7
TTIPn/TRINGn: Transmit Bipolar Tip/Ring for Channel 0~7
These pins are the differential line driver outputs. They will be in high-Z if pin OE is low or the corresponding pin TCLKn is low (pin OE is global control, while pin TCLKn is per-channel control). In host mode, each
pin can be in high-Z by programming a ‘1’ to the corresponding bit in register OE(1).
RTIPn/RRINGn: Receive Bipolar Tip/Ring for Channel 0~7
These pins are the differential line receiver inputs.
1. Register name is indicated by bold capital letter. For example, OE indicates Output Enable Register.
4
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-1 Pin Description (Continued)
Name
Type
Pin No.
TQFP144
Description
PBGA160
Transmit and Receive Digital Data Interface
TD0/TDP0
TD1/TDP1
TD2/TDP2
TD3/TDP3
TD4/TDP4
TD5/TDP5
TD6/TDP6
TD7/TDP7
37
30
80
73
108
101
8
1
N2
L2
L13
N13
B13
D13
D2
B2
38
31
79
72
109
102
7
144
N3
L3
L12
N12
B12
D12
D3
B3
I
BPVI0/TDN0
BPVI1/TDN1
BPVI2/TDN2
BPVI3/TDN3
BPVI4/TDN4
BPVI5/TDN5
BPVI6/TDN6
BPVI7/TDN7
TDn: Transmit Data for Channel 0~7
When the device is in Single Rail mode, the NRZ data to be transmitted is input on this pin. Data on TDn is
sampled into the device on the falling edges of TCLKn, and encoded by AMI or HDB3 line code rules
before being transmitted to the line.
BPVIn: Bipolar Violation Insertion for Channel 0~7
Bipolar violation insertion is available in Single Rail mode 2 (see Table-2 on page 13 and Table-3 on page
14) with AMI enabled. A low-to-high transition on this pin will make the next logic one to be transmitted on
TDn the same polarity as the previous pulse, and violate the AMI rule. This is for testing.
TDPn/TDNn: Positive/Negative Transmit Data for Channel 0~7
When the device is in Dual Rail Mode, the NRZ data to be transmitted for positive/negative pulse is input
on this pin. Data on TDPn/TDNn are sampled on the falling edges of TCLKn. The line code in dual rail
mode is as the follow:
TDPn
0
0
1
1
TDNn
0
1
0
1
Output Pulse
Space
Negative Pulse
Positive Pulse
Space
Pulling pin TDNn high for more than 16 consecutive TCLK clock cycles will configure the corresponding
channel into Single Rail mode 1 (see Table-2 on page 13 and Table-3 on page 14).
TCLK0
TCLK1
TCLK2
TCLK3
TCLK4
TCLK5
TCLK6
TCLK7
I
36
29
81
74
107
100
9
2
N1
L1
L14
N14
B14
D14
D1
B1
TCLKn: Transmit Clock for Channel 0~7
The clock of 2.048 MHz for transmit is input on this pin. The transmit data at TDn/TDPn or TDNn is sampled into the device on the falling edges of TCLKn.
Pulling TCLKn high for more than 16 MCLK cycles, the corresponding transmitter is set in Transmit All
Ones (TAOS) state (when MCLK is clocked). In TAOS state, the TAOS generator adopts MCLK as the
clock reference.
If TCLKn is low, the corresponding transmit channel is set into power down state, while driver output ports
become high-Z.
Different combinations of TCLKn and MCLK result in different transmit mode. It is summarized as the follows:
MCLK
Clocked
Clocked
Clocked
High/Low
High/Low
TCLKn
Clocked
Transmit Mode
Normal operation
Transmit All Ones (TAOS) signals to the line side in the corresponding
High (≥ 16 MCLK)
transmit channel.
Low (≥ 64 MCLK) The corresponding transmit channel is set into power down state.
TCLKn is clocked Normal operation
Transmit All Ones (TAOS) signals to the line side
TCLKn is high
in the corresponding transmit channel.
(≥ 16 TCLK1)
Corresponding transmit channel is set into power
TCLKn is low
TCLK1 is clocked
down state.
(≥ 64 TCLK1)
The receive path is not affected by the status of TCLK1. When MCLK
is high, all receive paths just slice the incoming data stream. When
MCLK is low, all the receive paths are powered down.
TCLK1 is unavailAll eight transmitters (TTIPn & TRINGn) will be in high-Z.
able.
5
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-1 Pin Description (Continued)
Name
RD0/RDP0
RD1/RDP1
RD2/RDP2
RD3/RDP3
RD4/RDP4
RD5/RDP5
RD6/RDP6
RD7/RDP7
CV0/RDN0
CV1/RDN1
CV2/RDN2
CV3/RDN3
CV4/RDN4
CV5/RDN5
CV6/RDN6
CV7/RDN7
RCLK0
RCLK1
RCLK2
RCLK3
RCLK4
RCLK5
RCLK6
RCLK7
MCLK
LOS0
LOS1
LOS2
LOS3
LOS4
LOS5
LOS6
LOS7
Type
O
High-Z
O
High-Z
Pin No.
TQFP144
Description
PBGA160
RDn: Receive Data for Channel 0~7
In Single Rail mode, the received NRZ data is output on this pin. The data is decoded by AMI or HDB3 line
code rule.
40
33
77
70
111
104
5
142
P2
M2
M13
P13
A13
C13
C2
A2
41
34
76
69
112
105
4
141
P3
M3
M12
P12
A12
C12
C3
A3
39
32
78
71
110
103
6
143
P1
M1
M14
P14
A14
C14
C1
A1
RCLKn: Receive Clock for Channel 0~7
In clock recovery mode, this pin outputs the recovered clock from signal received on RTIPn/RRINGn. The
received data are clocked out of the device on the rising edges of RCLKn if pin CLKE is high, or on falling
edges of RCLKn if pin CLKE is low.
In data recovery mode, RCLKn is the output of an internal exclusive OR (XOR) which is connected with
RDPn and RDNn. The clock is recovered from the signal on RCLKn.
If Receiver n is powered down, the corresponding RCLKn is in high-Z.
MCLK: Master Clock
This is an independent, free running reference clock. A clock of 2.048 MHz is supplied to this pin as the
clock reference of the device for normal operation.
In receive path, when MCLK is high, the device slices the incoming bipolar line signal into RZ pulse (Data
Recovery mode). When MCLK is low, all the receivers are powered down, and the output pins RCLKn,
RDPn and RDNn are switched to high-Z.
In transmit path, the operation mode is decided by the combination of MCLK and TCLKn (see TCLKn pin
description for details).
NOTE: Wait state generation via RDY/ACK is not available if MCLK is not provided.
I
10
E1
O
42
35
75
68
113
106
3
140
K4
K3
K12
K11
E11
E12
E3
E4
CVn: Code Violation for Channel 0~7
In Single Rail mode, the bipolar violation, code violation and excessive zeros will be reported by driving pin
CVn high for a full clock cycle. However, only bipolar violation is indicated when AMI decoder is selected.
RDPn/RDNn: Positive/Negative Receive Data for Channel 0~7
In Dual Rail Mode with clock recovery, these pins output the NRZ data. A high signal on RDPn indicates
the receipt of a positive pulse on RTIPn/RRINGn while a high signal on RDNn indicates the receipt of a
negative pulse on RTIPn/RRINGn.
The output data at RDn or RDPn/RDNn are clocked out on the falling edges of RCLK when the CLKE input
is low, or are clocked out on the rising edges of RCLK when CLKE is high.
In Dual Rail Mode without clock recovery, these pins output the raw RZ sliced data. In this data recovery
mode, the active polarity of RDPn/RDNn is determined by pin CLKE. When pin CLKE is low, RDPn/RDNn
is active low. When pin CLKE is high, RDPn/RDNn is active high.
In hardware mode, RDn or RDPn/RDNn will remain active during LOS. In host mode, these pins will either
remain active or insert alarm indication signal (AIS) into the receive path, determined by bit AISE in register GCF.
RDn or RDPn/RDNn is set into high-Z when the corresponding receiver is powered down.
LOSn: Loss of Signal Output for Channel 0~7
A high level on this pin indicates the loss of signal when there is no transition over a specified period of
time or no enough ones density in the received signal. The transition will return to low automatically when
there is enough transitions over a specified period of time with a certain ones density in the received signal. The LOS assertion and desertion criteria are described in 2.3.4 Loss of Signal (LOS) Detection.
6
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-1 Pin Description (Continued)
Name
Type
Pin No.
TQFP144
Description
PBGA160
Hardware/Host Control Interface
MODE2: Control Mode Select 2
The signal on this pin determines which control mode is selected to control the device:
MODE2
Low
VDDIO/2
High
I
MODE2
(Pulled to
VDDIO/2)
11
E2
Control Interface
Hardware Mode
Serial Host Interface
Parallel Host Interface
Hardware control pins include MODE[2:0], LP[7:0], CODE, CLKE, JAS and OE.
Serial host Interface pins include CS, SCLK, SDI, SDO and INT.
Parallel host Interface pins include CS, A[4:0], D[7:0], WR/DS, RD/R/W, ALE/AS, INT and RDY/ACK. The
device supports multiple parallel host interface as follows (refer to MODE1 and MODE0 pin descriptions
below for details):
MODE[2:0]
100
101
110
111
MODE1
I
43
K2
Host Interface
Non-multiplexed Motorola Mode Interface
Non-multiplexed Intel Mode Interface
Multiplexed Motorola Mode Interface
Multiplexed Intel Mode Interface
MODE1: Control Mode Select 1
In parallel host mode, the parallel interface operates with separate address bus and data bus when this pin
is low, and operates with multiplexed address and data bus when this pin is high.
In serial host mode or hardware mode, this pin should be grounded.
MODE0: Control Mode Select 0
In parallel host mode, the parallel host interface is configured for Motorola compatible hosts when this pin
is low, or for Intel compatible hosts when this pin is high.
MODE0/CODE
I
88
H12
CODE: Line Code Rule Select
In hardware control mode, the HDB3 encoder/decoder is enabled when this pin is low, and AMI encoder/
decoder is enabled when this pin is high. The selections affect all the channels.
In serial host mode, this pin should be grounded.
CS: Chip Select (Active Low)
In host mode, this pin is asserted low by the host to enable host interface. A high to low transition must
occur on this pin for each read/write operation and the level must not return to high until the operation is
over.
I
CS/JAS
(Pulled to
VDDIO/2)
87
J11
JAS: Jitter Attenuator Select
In hardware control mode, this pin globally determines the Jitter Attenuator position:
JAS
Low
VDDIO/2
High
Jitter Attenuator (JA) Configuration
JA in transmit path
JA not used
JA in receive path
7
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-1 Pin Description (Continued)
Name
Type
Pin No.
TQFP144
Description
PBGA160
SCLK: Shift Clock
In serial host mode, the signal on this pin is the shift clock for the serial interface. Data on pin SDO is
clocked out on falling edges of SCLK if pin CLKE is high, or on rising edges of SCLK if pin CLKE is low.
Data on pin SDI is always sampled on rising edges of SCLK.
SCLK/ALE/AS
I
86
J12
ALE: Address Latch Enable
In parallel Intel multiplexed host mode, the address on AD[4:0] is sampled into the device on the falling
edges of ALE (signals on AD[7:5] are ignored). In non-multiplexed host mode, ALE should be pulled high.
AS: Address Strobe (Active Low)
In parallel Motorola multiplexed host mode, the address on AD[4:0] is latched into the device on the falling
edges of AS (signals on AD[7:5] are ignored). In non-multiplexed host mode, AS should be pulled high.
NOTE: This pin is ignored in hardware control mode.
RD: Read Strobe (Active Low)
In parallel Intel multiplexed or non-multiplexed host mode, this pin is active low for read operation.
RD/R/W
I
85
J13
R/W: Read/Write Select
In parallel Motorola multiplexed or non-multiplexed host mode, the pin is active low for write operation and
high for read operation.
NOTE: This pin is ignored in hardware control mode.
SDI: Serial Data Input
In serial host mode, this pin input the data to the serial interface. Data on this pin is sampled on the rising
edges of SCLK.
WR: Write Strobe (Active Low)
In parallel Intel host mode, this pin is active low during write operation. The data on D[7:0] (in non-multiplexed mode) or AD[7:0] (in multiplexed mode) is sampled into the device on the rising edges of WR.
SDI/WR/DS
I
84
J14
DS: Data Strobe (Active Low)
In parallel Motorola host mode, this pin is active low. During a write operation (R/W = 0), the data on D[7:0]
(in non-multiplexed mode) or AD[7:0] (in multiplexed mode) is sampled into the device on the rising edges
of DS. During a read operation (R/W = 1), the data is driven to D[7:0] (in non-multiplexed mode) or AD[7:0]
(in multiplexed mode) by the device on the rising edges of DS.
In parallel Motorola non-multiplexed host mode, the address information on the 5 bits of address bus
A[4:0] are latched into the device on the falling edges of DS.
NOTE: This pin is ignored in hardware control mode.
SDO: Serial Data Output
In serial host mode, the data is output on this pin. In serial write operation, SDO is in high impedance for
the first 8 SCLK clock cycles and driven low for the remaining 8 SCLK clock cycles. In serial read operation, SDO is in high-Z only when SDI is in address/command byte. Data on pin SDO is clocked out of the
device on the falling edges of SCLK if pin CLKE is high, or on the rising edges of SCLK if pin CLKE is low.
SDO/RDY/ACK
O
83
K14
RDY: Ready Output
In parallel Intel host mode, the high level of this pin reports to the host that bus cycle can be completed,
while low reports the host must insert wait states.
ACK: Acknowledge Output (Active Low)
In parallel Motorola host mode, the low level of this pin indicates that valid information on the data bus is
ready for a read operation or acknowledges the acceptance of the written data during a write operation.
INT
O
Open
Drain
82
K13
INT: Interrupt (Active Low)
This is an open drain, active low interrupt output. Three sources may cause the interrupt . Refer to 2.18
Interrupt Handling for details.
8
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-1 Pin Description (Continued)
Name
Type
Pin No.
TQFP144
Description
PBGA160
LPn: Loopback Select 7~0
In hardware control mode, pin LPn configures the corresponding channel in different loopback mode, as
follows:
LP7/D7/AD7
LP6/D6/AD6
LP5/D5/AD5
LP4/D4/AD4
LP3/D3/AD3
LP2/D2/AD2
LP1/D1/AD1
LP0/D0/AD0
I/O
High-Z
28
27
26
25
24
23
22
21
K1
J1
J2
J3
J4
H2
H3
G2
LPn
Low
VDDIO/2
High
Loopback Configuration
Remote Loopback
No loopback
Analog Loopback
Refer to 2.16 Loopback Mode for details.
Dn: Data Bus 7~0
In non-multiplexed host mode, these pins are the bi-directional data bus.
ADn: Address/Data Bus 7~0
In multiplexed host mode, these pins are the multiplexed bi-directional address/data bus.
In serial host mode, these pins should be grounded.
MCn: Performance Monitor Configuration 3~0
In hardware control mode, A4 must be connected to GND. MC[3:0] are used to select one transmitter or
receiver of channel 1 to 7 for non-intrusive monitoring. Channel 0 is used as the monitoring channel. If a
transmitter is monitored, signals on the corresponding pins TTIPn and TRINGn are internally transmitted
to RTIP0 and RRING0. If a receiver is monitored, signals on the corresponding pins RTIPn and RRINGn
are internally transmitted to RTIP0 and RRING0. The monitored is then output to RDP0 and RDN0 pins.
In host mode operation, the signals monitored by channel 0 can be routed to TTIP0/RING0 by activating
the remote loopback in this channel. Refer to 2.19 G.772 Monitoring for more details.
A4
MC3/A3
MC2/A2
MC1/A1
MC0/A0
I
12
13
14
15
16
F4
F3
F2
F1
G3
Performance Monitor Configuration determined by MC[3:0] is shown below. Note that if MC[2:0] = 000, the
device is in normal operation of all the channels.
MC[3:0]
Monitoring Configuration
0000
Normal operation without monitoring
0001
Monitor Receiver 1
0010
Monitor Receiver 2
0011
Monitor Receiver 3
0100
Monitor Receiver 4
0101
Monitor Receiver 5
0110
Monitor Receiver 6
0111
Monitor Receiver 7
1000
Normal operation without monitoring
1001
Monitor Transmitter 1
1010
Monitor Transmitter 2
1011
Monitor Transmitter 3
1100
Monitor Transmitter 4
1101
Monitor Transmitter 5
1110
Monitor Transmitter 6
Monitor Transmitter 7
1111
An: Address Bus 4~0
When pin MODE1 is low, the parallel host interface operates with separate address and data bus. In this
mode, the signal on this pin is the address bus of the host interface.
OE
I
114
E14
OE: Output Driver Enable
Pulling this pin low can drive all driver output into high-Z for redundancy application without external
mechanical relays. In this condition, all other internal circuits remain active.
9
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-1 Pin Description (Continued)
Name
CLKE
Type
I
Pin No.
TQFP144
115
Description
PBGA160
E13
CLKE: Clock Edge Select
The signal on this pin determines the active edge of RCLKn and SCLK in clock recovery mode, or determines the active level of RDPn and RDNn in the data recovery mode. See 2.2 Clock Edges on page 14 for
details.
JTAG Signals
I
TRST
95
G12
TRST: JTAG Test Port Reset (Active Low)
This is the active low asynchronous reset to the JTAG Test Port. This pin has an internal pull-up resistor
and it can be left open.
96
F11
TMS: JTAG Test Mode Select
The signal on this pin controls the JTAG test performance and is clocked into the device on the rising
edges of TCK. This pin has an internal pull-up resistor and it can be left open.
F14
TCK: JTAG Test Clock
This pin input the clock of the JTAG Test. The data on TDI and TMS are clocked into the device on the rising edges of TCK, while the data on TDO is clocked out of the device on the falling edges of TCK. This pin
should be connected to GNDIO or VDDIO pin when unused.
98
F13
TDO: JTAG Test Data Output
This pin output the serial data of the JTAG Test. The data on TDO is clocked out of the device on the falling edges of TCK. TDO is a high-Z output signal. It is active only when scanning of data is out. This pin
should be left float when unused.
99
F12
TDI: JTAG Test Data Input
This pin input the serial data of the JTAG Test. The data on TDI is clocked into the device on the rising
edges of TCK. This pin has an internal pull-up resistor and it can be left open.
Pull-up
I
TMS
Pull-up
TCK
I
97
O
TDO
High-Z
I
TDI
Pull-up
Power Supplies and Grounds
VDDIO
-
17
92
G1
G14
3.3 V I/O Power Supply
GNDIO
-
18
91
G4
G11
I/O GND
-
44
53
56
65
116
125
128
137
N4, P4
L4, M4
L11, M11
N11, P11
A11, B11
C11, D11
C4, D4
A4, B4
GNDT0
GNDT1
GNDT2
GNDT3
GNDT4
GNDT5
GNDT6
GNDT7
-
47
50
59
62
119
122
131
134
N6, P6
L6, M6
L9, M9
N9, P9
A9, B9
C9, D9
C6, D6
A6, B6
VDDD
VDDA
-
19
90
H1
H14
VDDT0
VDDT1
VDDT2
VDDT3
VDDT4
VDDT5
VDDT6
VDDT7
3.3 V/5 V Power Supply for Transmitter Driver
All VDDT pins must be connected to 3.3 V or all VDDT must be connected to 5 V. It is not allowed to leave
any of the VDDT pins open (not-connected) even if the channel is not used.
Analog GND for Transmitter Driver
3.3 V Digital/Analog Core Power Supply
10
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-1 Pin Description (Continued)
Name
Type
GNDD
GNDA
-
Pin No.
TQFP144
PBGA160
20
89
H4
H11
Description
Digital/Analog Core GND
Others
IC
O
93
94
G13
H13
IC: Internal Connection
Internal use. Leave it float for normal operation.
11
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
2
FUNCTIONAL DESCRIPTION
2.1
OVERVIEW
INDUSTRIAL TEMPERATURE RANGES
The Dual Rail interface consists of TDPn1, TDNn, TCLKn, RDPn,
RDNn and RCLKn. Data transmitted from TDPn and TDNn appears on
TTIPn and TRINGn at the line interface; data received from the RTIPn
and RRINGn at the line interface are transferred to RDPn and RDNn
while the recovered clock extracting from the received data stream
outputs on RCLKn. In Dual Rail operation, the clock/data recovery mode
is selectable. Dual Rail interface with clock recovery shown in Figure-4
is a default configuration mode. Dual Rail interface with data recovery is
shown in Figure-5. Pin RDPn and RDNn, are raw RZ slice outputs and
internally connected to an EXOR which is fed to the RCLKn output for
external clock recovery applications.
The IDT82V2058 is a fully integrated octal short-haul line interface
unit, which contains eight transmit and receive channels for use in E1
applications. The receiver performs clock and data recovery. As an
option, the raw sliced data (no retiming) can be output to the system.
Transmit equalization is implemented with low-impedance output drivers
that provide shaped waveforms to the transformer, guaranteeing
template conformance. A selectable jitter attenuator may be placed in
the receive path or the transmit path. Moreover, multiple testing functions, such as error detection, loopback and JTAG boundary scan are
also provided. The device is optimized for flexible software control
through a serial or parallel host mode interface. Hardware control is also
available. Figure-1 on page 1 shows one of the eight identical channels
operation.
In Single Rail mode, data transmitted from TDn appears on TTIPn
and TRINGn at the line interface. Data received from the RTIPn and
RRINGn at the line interface appears on RDn while the recovered clock
extracting from the received data stream outputs on RCLKn. When the
device is in single rail interface, the selectable AMI or HDB3 line
encoder/decoder is available and any code violation in the received data
will be indicated at the CVn pin. The Single Rail mode has 2 sub-modes:
Single Rail Mode 1 and Single Rail Mode 2. Single Rail Mode 1, whose
interface is composed of TDn, TCLKn, RDn, CVn and RCLKn, is realized by pulling pin TDNn high for more than 16 consecutive TCLK
cycles. Single Rail Mode 2, whose interface is composed of TDn,
TCLKn, RDn, CVn, RCLKn and BPVIn, is realized by setting bit CRS in
register e-CRS2 and bit SING in register e-SING. The difference
between them is that, in the latter mode bipolar violation can be inserted
via pin BPVIn if AMI line code is selected.
2.1.1 SYSTEM INTERFACE
The system interface of each channel can be configured to operate
in different modes:
1. Single rail interface with clock recovery.
2. Dual rail interface with clock recovery.
3. Dual rail interface with data recovery (that is, with raw data
slicing only and without clock recovery).
Each signal pin on system side has multiple functions depending on
which operation mode the device is in.
The configuration of the Hardware Mode System Interface is summarized in Table-2. The configuration of the Host Mode System Interface is
summarized in Table-3.
1. The footprint ‘n’ (n = 0 - 7) indicates one of the eight channels.
2.
LOS
Detector
RTIPn
Slicer
RRINGn
The first letter ‘e-’ indicates expanded register.
One of Eight Identical Channels
LOSn
CLK&Data
Recovery
(DPLL)
Jitter
Attenuator
HDB3/
AMI
Decoder
RCLKn
RDPn
RDNn
Waveform
Shaper
Jitter
Attenuator
HDB3/
AMI
Encoder
TCLKn
TDPn
TDNn
Peak
Detector
TTIPn
TRINGn
Line
Driver
Transmit
All Ones
Note: The grey blocks are bypassed and the dotted blocks are selectable.
Figure-4 Dual Rail Interface with Clock Recovery
12
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
LOS
Detector
RTIPn
Slicer
RRINGn
One of Eight Identical Channels
LOSn
CLK&Data
Recovery
(DPLL)
Jitter
Attenuator
HDB3/
AMI
Decoder
Waveform
Shaper
Jitter
Attenuator
HDB3/
AMI
Encoder
RCLKn
(RDP RDN)
RDPn
RDNn
Peak
Detector
TTIPn
Line
Driver
TRINGn
TCLKn
TDPn
TDNn
Transmit
All Ones
Note: The grey blocks are bypassed and the dotted blocks are selectable
Figure-5 Dual Rail Interface with Data Recovery
One of Eight Identical Channels
LOS
Detector
RTIPn
Slicer
RRINGn
LOSn
CLK&Data
Recovery
(DPLL)
Jitter
Attenuator
HDB3/
AMI
Decoder
Waveform
Shaper
Jitter
Attenuator
HDB3/
AMI
Encoder
RCLKn
RDn
CVn
Peak
Detector
TTIPn
TRINGn
Line
Driver
TCLKn
TDn
BPVIn/TDNn
Transmit
All Ones
Figure-6 Single Rail Mode
Table-2 System Interface Configuration (In Hardware Mode)
Pin MCLK
Pin TDNn
Clocked
High (≥ 16 MCLK)
Interface
Clocked
Pulse
Dual Rail mode with Clock Recovery
High
Pulse
Low
Pulse
Dual Rail mode with Data Recovery. Receive just slices the incoming data. Transmit is determined
by the status of TCLKn.
Receiver is powered down. Transmit is determined by the status of TCLKn.
Single Rail Mode 1
13
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-3 System Interface Configuration (In Host Mode)
Pin MCLK
Pin TDNn
CRSn in e-CRS
SINGn in e-SING
Interface
Clocked
Clocked
Clocked
High
Pulse
Pulse
0
0
0
0
1
0
Clocked
Pulse
1
0
High
Pulse
-
-
Low
Pulse
-
-
Single Rail Mode 1
Single Rail Mode 2
Dual Rail mode with Clock Recovery
Dual Rail mode with Data Recovery. Receive just slices the incoming data. Transmit is
determined by the status of TCLKn.
Dual Rail mode with Data Recovery. Receive just slices the incoming data. Transmit is
determined by the status of TCLKn.
Receiver is powered down. Transmit is determined by the status of TCLKn.
Table-4 Active Clock Edge and Active Level
Pin RDn/RDPn and CVn/RDNn
Clock Recovery
Slicer Output
Pin CLKE
2.2
High
RCLKn
Active High
Active High
SCLK
Active High
Low
RCLKn
Active High
Active Low
SCLK
Active High
CLOCK EDGES
data recovery mode, the slicer output is sent to Clock and Data
Recovery circuit for abstracting retimed data and optional decoding. The
slicer circuit has a built-in peak detector from which the slicing threshold
is derived. The slicing threshold is default to 50% (typical) of the peak
value.
The active edge of RCLKn and SCLK are selectable. If pin CLKE is
high, the active edge of RCLKn is the rising edge, as for SCLK, that is
falling edge. On the contrary, if CLKE is low, the active edge of RCLK is
the falling edge and that of SCLK is rising edge. Pins RDn/RDPn, CVn/
RDNn and SDO are always active high, and those output signals are
clocked out on the active edge of RCLKn and SCLK respectively. See
Table-4 Active Clock Edge and Active Level on page 14 for details.
However, in dual rail mode without clock recovery, pin CLKE is used to
set the active level for RDPn/RDNn raw slicing output: High for active
high polarity and low for active low. It should be noted that data on pin
SDI are always active high and are sampled on the rising edges of
SCLK. The data on pin TDn/TDPn or BPVIn/TDNn are also always
active high but are sampled on the falling edges of TCLKn, despite the
level on CLKE.
2.3
Pin SDO
Signals with an attenuation of up to 12 dB (from 2.4 V) can be recovered by the receiver. To provide immunity from impulsive noise, the peak
detectors are held above a minimum level of 0.150 V typically, despite
the received signal level.
2.3.2 CLOCK AND DATA RECOVERY
The Clock and Data Recovery is accomplished by Digital Phase
Locked Loop (DPLL). The DPLL is clocked 16 times of the received
clock rate, i.e. 32.768 MHz in E1 mode. The recovered data and clock
from DPLL is then sent to the selectable Jitter Attenuator or decoder for
further processing.
RECEIVER
The clock recovery and data recovery mode can be selected on a per
channel basis by setting bit CRSn in register e-CRS. When bit CRSn is
defaulted to ‘0’, the corresponding channel operates in data and clock
recovery mode. The recovered clock is output on pin RCLKn and retimed NRZ data are output on pin RDPn/RDNn in dual rail mode or on
RDn in single rail mode. When bit CRSn is set to ‘1’, dual rail mode with
data recovery is enabled in the corresponding channel and the clock
recovery is bypassed. In this condition, the analog line signals are
converted to RZ digital bit streams on the RDPn/RDNn pins and internally connected to an EXOR which is fed to the RCLKn output for
external clock recovery applications.
In receive path, the line signals couple into RRINGn and RTIPn via a
transformer and are converted into RZ digital pulses by a data slicer.
Adaptation for attenuation is achieved using an integral peak detector
that sets the slicing levels. Clock and data are recovered from the
received RZ digital pulses by a digital phase-locked loop that provides
jitter accommodation. After passing through the selectable jitter attenuator, the recovered data are decoded using HDB3 or AMI line code rules
and clocked out of pin RDn in single rail mode, or presented on RDPn/
RDNn in an undecoded dual rail NRZ format. Loss of signal, alarm indication signal, line code violation and excessive zeros are detected.
These various changes in status may be enabled to generate interrupts.
If MCLK is pulled high, all the receivers will enter the dual rail mode
with data recovery. In this case, register e-CRS is ignored.
2.3.1 PEAK DETECTOR AND SLICER
The slicer determines the presence and polarity of the received
pulses. In data recovery mode, the raw positive slicer output appears on
RDPn while the negative slicer output appears on RDNn. In clock and
14
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
The configuration of the line code rule is summarized in Table-5.
2.3.3 HDB3/AMI LINE CODE RULE
Selectable HDB3 and AMI line coding/decoding is provided when the
device is configured in single rail mode. HDB3 rules is enabled by
setting bit CODE in register GCF to ‘0’ or pulling pin CODE low. AMI rule
is enabled by setting bit CODE in register GCF to ‘1’ or pulling pin CODE
high. The settings affect all eight channels.
2.3.4 LOSS OF SIGNAL (LOS) DETECTION
The Loss of Signal Detector monitors the amplitude and density of
the received signal on receiver line before the transformer (measured on
port A, B shown in Figure-10). The loss condition is reported by pulling
pin LOSn high. At the same time, LOS alarm registers track LOS condition. When LOS is detected or cleared, an interrupt will generate if not
masked. In host mode, the detection supports ITU G.775 and ETSI 300
233. In hardware mode, it supports the ITU G.775.
Individual line code rule selection for each channel, if needed, is
available by setting bit SINGn in register e-SING to ‘1’ (to activate bit
CODEn in register e-CODE) and programming bit CODEn to select line
code rules in the corresponding channel: ‘0’ for HDB3, while ‘1’ for AMI.
In this case, the value in bit CODE in register GCF or pin CODE for
global control is unaffected in the corresponding channel and only affect
in other channels.
Table-6 summarizes the conditions of LOS in clock recovery mode.
During LOS, the RDPn/RDNn continue to output the sliced data
when bit AISE in register GCF is set to ‘0’ or output all ones as AIS
(alarm indication signal) when bit AISE is set to ‘1’. The RCLKn is
replaced by MCLK only if the bit AISE is set.
In dual rail mode, the decoder/encoder are bypassed. Bit CODE in
register GCF, bit CODEn in register e-CODE and pin CODE are ignored.
Table-5 Configuration of the Line Code Rule
Hardware Mode
Line Code Rule
CODE
Low
CODE in GCF
0
0
1
1
0
1
All channels in HDB3
High
All channels in AMI
CODEn in e-CODE
0/1
0
0/1
1
1
0
Host Mode
SINGn in e-SING
0
1
0
1
1
1
Line Code Rule
All channels in HDB3
All channels in AMI
CHn in AMI
CHn in HDB3
Table-6 LOS Condition in Clock Recovery Mode
Standard
G.775
1.
LOS
Detected
Continuous Intervals
LOS
Cleared
Density
Amplitude(1)
Amplitude(1)
ETSI 300 233
32
2048 (1 ms)
below typical 200 mVp
below typical 200 mVp
12.5% (4 marks in a sliding 32-bit period) with no more
than 15 continuous zeros
12.5% (4 marks in a sliding 32-bit period) with no more
than 15 continuous zeros
exceed typical 250 mVp
exceed typical 250 mVp
Signal on
LOSn
High
Low
LOS levels at device (RTIPn, RRINGn) with all ones signal. For more detail regarding the LOS parameters, please refer to Receiver Characteristics on page 42.
2.3.5 ALARM INDICATION SIGNAL (AIS) DETECTION
Alarm Indication Signal is available only in host mode with clock
recovery, as shown in Table-7.
determine whether excessive zeros and code violation are reported
respectively. When the device is configured in AMI decoding mode, only
bipolar violation can be reported.
2.3.6 ERROR DETECTION
The device can detect excessive zeros, bipolar violation and HDB3
code violation, as shown in Figure-7 and Figure-8. All the three kinds of
errors are reported in both host mode and hardware mode with HDB3
line code rule used. In host mode, the e-CZER and e-CODV are used to
The error detection is available only in single rail mode in which the
pin CVn/RDNn is used as error report output (CVn pin).
The configuration and report status of error detection are summarized in Table-8.
Table-7 AIS Condition
ITU G.775
(Register LAC defaulted to ‘0’)
AIS Detected
AIS Cleared
ETSI 300 233
(Register LAC set to ‘1’)
Less than 3 zeros contained in each of two consecutive 512-bit stream are received Less than 3 zeros contained in a 512-bit stream are received
3 or more zeros contained in each of two consecutive 512-bit stream are received 3 or more zeros contained in a 512-bit stream are received
15
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-8 Error Detection
Hardware Mode
Host Mode
Line Code
Pin CVn Reports
Line Code
AMI
Bipolar Violation
AMI
HDB3
Bipolar Violation +
Code Violation
+ Excessive Zeros
CODVn in e-CODV CZERn in e-CZER
HDB3
Pin CVn Reports
-
-
Bipolar Violation
0
0
Bipolar Violation + Code Violation
0
1
Bipolar Violation + Code Violation + Excessive Zeros
1
0
Bipolar Violation
1
1
Bipolar Violation + Excessive Zeros
RCLKn
RTIPn
1
RRINGn
3
5
2
V
4
RDn
1
7
6
2
3
4
5
V
6
CVn
Bipolar Violation
Bipolar Violation detected
Figure-7 AMI Bipolar Violation
Code violation
RCLKn
RTIPn
1
3
5
4 consecutive zeros
RRINGn
RDn
2
4
1
V
2
3
V
6
4
5
6
CVn
Excessive zeros detected
Code violation detected
Figure-8 HDB3 Code Violation & Excessive Zeros
2.4
TRANSMITTER
provided with a FIFO through which the data to be transmitted are
passing. A low jitter clock is generated by an integral digital phaselocked loop and is used to read data from the FIFO. The shape of the
pulses should meet the E1 pulse template after the signal passes
through different cable lengths or types. Bipolar violation, for diagnosis,
can be inserted on pin BPVIn if AMI line code rule is enabled.
In transmit path, data in NRZ format are clocked into the device on
TDn and encoded by AMI or HDB3 line code rules when single rail mode
is configured or pre-encoded data in NRZ format are input on TDPn and
TDNn when dual rail mode is configured. The data are sampled into the
device on falling edges of TCLKn. Jitter attenuator, if enabled, is
16
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
2.4.1 WAVEFORM SHAPER
E1 pulse template, specified in ITU-T G.703, is shown in Figure-9.
The device has built-in transmit waveform templates for cable of 75 Ω or
120 Ω.
For applications which require line synchronization, the line clock
needed to be extracted for the internal synchronization, the jitter attenuator is set in the receive path. Another use of the jitter attenuator is to
provide clock smoothing in the transmit path for applications such as
synchronous/asynchronous demultiplexing applications. In these applications, TCLK will have an instantaneous frequency that is higher than
the nominal E1 data rate and in order to set the average long-term TCLK
frequency within the transmit line rate specifications, periods of TCLK
are suppressed (gapped).
The built-in waveform shaper uses an internal high frequency clock
which is 16XMCLK as the clock reference. This function will be
bypassed when MCLK is unavailable.
1.20
The jitter attenuator integrates a FIFO which can accommodate a
gapped TCLK. In host mode, the FIFO length can be 32 X 2 or 64 X 2
bits by programming bit JADP in GCF. In hardware mode, it is fixed to 64
X 2 bits. The FIFO length determines the maximum permissible gap
width (see Table-9 Gap Width Limitation). Exceeding these values will
cause FIFO overflow or underflow. The data is 16 or 32 bits’ delay
through the jitter attenuator in the corresponding transmit or receive
path. The constant delay feature is crucial for the applications requiring
“hitless” switching.
1.00
Normalized Amplitude
0.80
0.60
0.40
0.20
Table-9 Gap Width Limitation
0.00
-0.20
-300
-200
-100
0
Time (ns)
100
200
FIFO Length
64 bit
32 bit
300
Figure-9 CEPT Waveform Template
In host mode, bit JABW in GCF determines the jitter attenuator 3 dB
corner frequency (fc). In hardware mode, the fc is fixed to 1.7 Hz. Generally, the lower the fc is, the higher the attenuation. However, lower fc
comes at the expense of increased acquisition time. Therefore, the
optimum fc is to optimize both the attenuation and the acquisition time.
In addition, the longer FIFO length results in an increased throughput
delay and also influences the 3 dB corner frequency. Generally, it’s
recommended to use the lower corner frequency and the shortest FIFO
length that can still meet jitter attenuation requirements.
2.4.2 BIPOLAR VIOLATION INSERTION
When configured in Single Rail Mode 2 with AMI line code enabled,
pin TDNn/BPVIn is used as BPVI input. A low-to-high transition on this
pin inserts a bipolar violation on the next available mark in the transmit
data stream. Sampling occurs on the falling edges of TCLK. But in TAOS
(Transmit All Ones) with Analog Loopback and Remote Loopback, the
BPVI is disabled. In TAOS with Digital Loopback, the BPVI is looped
back to the system side, so the data to be transmitted on TTIPn and
TRINGn are all ones with no bipolar violation.
2.5
Max. Gap Width
56 UI
28 UI
The output jitter meets ITU-T G.736, ITU-T G.742, ITU-T G.783 and
ETSI CTR 12/13.
JITTER ATTENUATOR
2.6
The jitter attenuator can be selected to work either in transmit path or
in receive path or not used. The selection is accomplished by setting pin
JAS in hardware mode or configuring bits JACF[1:0] in register GCF in
host mode, which affects all eight channels.
LINE INTERFACE CIRCUITRY
The transmit and receive interface RTIPn/RRINGn and TTIPn/
TRINGn connections provide a matched interface to the cable. Figure10 shows the appropriate external components to connect with the cable
for one transmit/receive channel. Table-10 summarizes the component
values based on the specific application.
17
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-10 External Components Values
RT
RR
Cp
D1 - D4
75 Ω Coax
9.5 Ω ± 1%
9.31 Ω ± 1%
120 Ω Twisted Pair
9.5 Ω ± 1%
15 Ω ± 1%
2200 pF
Nihon Inter Electronics - EP05Q03L, 11EQS03L,
EC10QS04, EC10QS03L;
Motorola - MBR0540T1
1
A
2:1
• •
•
0.22 µF
RX Line
•
B
•
1
2:1
• •
TX Line
Cp
One of Eight Identical Channels
1 kΩ
RTIPn
RR
RR
1 kΩ
VDDT
D4
RT
D3
IDT82V2058
Component
RRINGn
TTIPn
VDDT
2
0.1 µF
VDDT
D2
RT
D1
•
VDDDn
GNDTn
·
68 µF3
•
TRINGn
NOTE:
1. Pulse T1124 transformer is recommended to be used in Standard (STD) operating temperature range (0°C to 70°C), while Pulse T1114
transformer is recommended to be used in Extended (EXT) operating temperature range is -40°C to +85°C. See Transformer Specifications Table for
details.
2. Typical value. Adjust for actual board parasitics to obtain optimum return loss.
3. Common decoupling capacitor for all VDDT and GNDT pins. One per chip.
Figure-10 External Transmit/Receive Line Circuitry
2.7
TRANSMIT DRIVER POWER SUPPLY
All transmit driver power supplies must be 5.0 V or 3.3 V.
Despite the power supply voltage, the 75 Ω/120 Ω lines are driven
through a pair of 9.5 Ω series resistors and a 1:2 transformer.
Table-11 Transformer Specifications(1)
Part No.
STD Temp. EXT Temp.
T1124
T1114
1.
Turns Ratio (Pri: sec ± 2%)
Transmit
Receive
1:2CT
1CT:2
Electrical Specification @ 25°C
OCL @ 25°C (mH MIN)
LL (µH MAX)
Transmit
Receive
Transmit
Receive
1.2
1.2
.6
.6
CW/W (pF MAX)
Transmit Receive
35
35
Package/Schematic
TOU/3
Pulse T1124 transformer is recommended to be used in Standard (STD) operating temperature range (0°C to 70°C), while Pulse T1114 transformer is recommended to be used in
Extended (EXT) operating temperature range is -40°C to +85°C.
2.8
POWER DRIVER FAILURE MONITOR
2.9
An internal power Driver Failure Monitor (DFMON), parallel
connected with TTIPn and TRINGn, can detect short circuit failure
between TTIPn and TRINGn pins. Bit SCPB in register GCF decides
whether the output driver short circuit protection is enabled. When the
short circuit protection is enabled, the driver output current is limited to a
typical value: 180 mAp. Also, register DF, DFI and DFM will be available.
When DFMON will detect a short circuit, register DF will be set. With a
short circuit failure detected and short circuit protection enabled, register
DFI will be set and an interrupt will be generated on pin INT.
TRANSMIT LINE SIDE SHORT CIRCUIT FAILURE
DETECTION
A pair of 9.5 Ω serial resistors connect with TTIPn and TRINGn pins
and limit the output current. In this case, the output current is a limited
value which is always lower than the typical line short circuit current 180
mAp, even if the transmit line side is shorted.
Refer to Table-10 External Components Values for details.
18
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
2.10 LINE PROTECTION
During Digital Loopback, the received signal on the receive line is still
monitored by the LOS Detector (See 2.3.4 Loss of Signal (LOS) Detection for details). In case of a LOS condition and AIS insertion enabled, all
ones signal will be output on RDPn/RDNn. With ATAO enabled, all ones
signal will be also output on TTIPn/TRINGn. AIS insertion can be
enabled by setting AISE bit in register GCF and ATAO can be enabled
by setting register ATAO (default disabled).
In transmit side, the Schottky diodes D1~D4 are required to protect
the line driver and improve the design robustness. In receive side, the
series resistors of 1 kΩ are used to protect the receiver against current
surges coupled in the device. The series resistors do not affect the
receiver sensitivity, since the receiver impedance is as high as 120 kΩ
typically.
2.13 POWER ON RESET
2.16.2 ANALOG LOOPBACK
By programming the bits of register ALB or pulling pin LPn high,
each channel of the device can be configured in Analog Loopback. In
this configuration, the data to be transmitted output from the line driver
are internally looped back to the slicer and peak detector in the receive
path and output on RCLKn, RDn/RDPn and CVn/RDNn. The data to be
transmitted are still output on TTIPn and TRINGn while the data
received on RTIPn and RRINGn are ignored. The LOS Detector (See
2.3.4 Loss of Signal (LOS) Detection for details) is still in use and monitors the internal looped back data. If a LOS condition on TDPn/TDNn is
expected during Analog Loopback, ATAO should be disabled (default).
Figure-12 shows the process.
During power up, an internal reset signal sets all the registers to
default values. The power-on reset takes at least 10 µs, starting from
when the power supply exceeds 2/3 VDDA.
The TTIPn and RTIPn, TRINGn and RRINGn cannot be connected
directly to do the external analog loopback test. Line impedance loading
is required to conduct the external analog loopback test.
2.14 POWER DOWN
2.16.3 REMOTE LOOPBACK
By programming the bits of register RLB or pulling pin LPn low, each
channel of the device can be set in Remote Loopback. In this configuration, the data and clock recovered by the clock and data recovery
circuits are looped to waveform shaper and output on TTIPn and
TRINGn. The jitter attenuator is also included in loopback when enabled
in the transmit or receive path. The received data and clock are still
output on RCLKn, RDn/RDPn and CVn/RDNn while the data to be transmitted on TCLKn, TDn/TDPn and BPVIn/TDNn are ignored. The LOs
Detector is still in use. Figure-13 shows the process.
2.11 HITLESS PROTECTION SWITCHING (HPS)
The IDT82V2058 transceivers include an output driver with high-Z
feature for E1 redundancy applications. This feature reduces the cost of
redundancy protection by eliminating external relays. Details of HPS are
described in relative Application Note.
2.12 SOFTWARE RESET
Writing register RS will cause software reset by initiating about 1 µs
reset cycle. This operation set all the registers to their default value.
Each transmit channel will be powered down by pulling pin TCLKn
low for more than 64 MCLK cycles (if MCLK is available) or about 30 µs
(if MCLK is not available). In host mode, each transmit channel will also
be powered down by setting bit TPDNn in register e-TPDN to ‘1’.
All the receivers will be powered down when MCLK is low. When
MCLK is clocked or high, setting bit RPDNn in register e-RPDN to ‘1’ will
configure the corresponding receiver to be powered down.
2.15 INTERFACE WITH 5 V LOGIC
2.16.4 DUAL LOOPBACK
Dual Loopback mode is set by setting bit DLBn in register DLB and
bit RLBn in register RLB to ‘1’. In this configuration, after passing the
encoder, the data and clock to be transmitted are looped back to
decoder directly and output on RCLKn, RDn/RDPn and CVn/RDNn. The
recovered data from RTIPn and RRINGn are looped back to waveform
shaper through JA (if selected) and output on TTIPn and TRINGn. The
LOS Detector is still in use. Figure-14 shows the process.
The IDT82V2058 can interface directly with 5 V TTL family devices.
The internal input pads are tolerant to 5 V output from TTL and CMOS
family devices.
2.16 LOOPBACK MODE
The device provides four different diagnostic loopback configurations: Digital Loopback, Analog Loopback, Remote Loopback and Dual
Loopback. In host mode, these functions are implemented by programming the registers DLB, ALB and RLB respectively. In hardware mode,
only Analog Loopback and Remote Loopback can be selected by pin
LPn.
2.16.5 TRANSMIT ALL ONES (TAOS)
In hardware mode, the TAOS mode is set by pulling pin TCLKn high
for more than 16 MCLK cycles. In host mode, TAOS mode is set by
programming register TAO. In addition, automatic TAOS signals are
inserted by setting register ATAO when Loss of Signal occurs. Note that
the TAOS generator adopts MCLK as a timing reference. In order to
assure that the output frequency is within specified limits, MCLK must
have the applicable stability.
2.16.1 DIGITAL LOOPBACK
By programming the bits of register DLB, each channel of the device
can be configured in Local Digital Loopback. In this configuration, the
data and clock to be transmitted, after passing the encoder, are looped
back to Jitter Attenuator (if enabled) and decoder in the receive path,
then output on RCLKn, RDn/RDPn and CVn/RDNn. The data to be
transmitted are still output on TTIPn and TRINGn while the data
received on RTIPn and RRINGn are ignored. The Loss Detector is still in
use. Figure-11 shows the process.
The TAOS mode, the TAOS mode with Digital Loopback and the
TAOS mode with Analog Loopback are shown in Figure-15, Figure-16
and Figure-17.
19
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
One of Eight Identical Channels
LOS
Detector
CLK&Data
Recovery
(DPLL)
RTIPn
Slicer
RRINGn
Line
Driver
TRINGn
Jitter
Attenuator
HDB3/AMI
Decoder
RCLKn
RDn/RDPn
CVn/RDNn
Jitter
Attenuator
HDB3/AMI
Encoder
TCLKn
TDn/TDPn
BPVIn/TDNn
Digital
Loopback
Peak
Detector
TTIPn
LOSn
Waveform
Shaper
Transmit
All Ones
Figure-11 Digital Loopback
One of Eight Identical Channels
LOS
Detector
RTIPn
CLK&Data
Recovery
(DPLL)
Slicer
RRINGn
Analog
Loopback
LOSn
Jitter
Attenuator
HDB3/AMI
Decoder
RCLKn
RDn/RDPn
CVn/RDNn
HDB3/AMI
Encoder
TCLKn
TDn/TDPn
BPVIn/TDNn
Peak
Detector
TTIPn
Line
Driver
TRINGn
Jitter
Attenuator
Waveform
Shaper
Transmit
All Ones
Figure-12 Analog Loopback
One of Eight Identical Channels
LOS
Detector
RTIPn
Slicer
RRINGn
LOSn
CLK&Data
Recovery
(DPLL)
Jitter
Attenuator
Peak
Detector
TTIPn
TRINGn
HDB3/AMI
Decoder
RCLKn
RDn/RDPn
CVn/RDNn
HDB3/AMI
Encoder
TCLKn
TDn/TDPn
BPVIn/TDNn
Remote
Loopback
Line
Driver
Waveform
Shaper
Jitter
Attenuator
Transmit
All Ones
Figure-13 Remote Loopback
20
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
LOS
Detector
RTIPn
Slicer
RRINGn
CLK&Data
Recovery
(DPLL)
One of Eight Identical Channels
LOSn
Jitter
Attenuator
HDB3/AMI
Decoder
RCLKn
RDn/RDPn
CVn/RDNn
HDB3/AMI
Encoder
TCLKn
TDn/TDPn
BPVIn/TDNn
Peak
Detector
TTIPn
Line
Driver
TRINGn
Jitter
Attenuator
Waveform
Shaper
Transmit
All Ones
Figure-14 Dual Loopback
LOS
Detector
RTIPn
Slicer
RRINGn
CLK&Data
Recovery
(DPLL)
One of Eight Identical Channels
LOSn
HDB3/AMI
Decoder
Jitter
Attenuator
RCLKn
RDn/RDPn
CVn/RDNn
Peak
Detector
TTIPn
Line
Driver
TRINGn
Waveform
Shaper
Jitter
Attenuator
HDB3/AMI
Encoder
TCLKn
TDn/TDPn
BPVIn/TDNn
Transmit
All Ones
Figure-15 TAOS Data Path
LOS
Detector
RTIPn
Slicer
RRINGn
CLK&Data
Recovery
(DPLL)
One of Eight Identical Channels
LOSn
Jitter
Attenuator
HDB3/AMI
Decoder
RCLKn
RDn/RDPn
CVn/RDNn
Jitter
Attenuator
HDB3/AMI
Encoder
TCLKn
TDn/TDPn
BPVIn/TDNn
Peak
Detector
TTIPn
TRINGn
Line
Driver
Waveform
Shaper
Transmit
All Ones
Figure-16 TAOS with Digital Loopback
21
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
One of Eight Identical Channels
LOS
Detector
RTIPn
Slicer
RRINGn
LOSn
CLK&Data
Recovery
(DPLL)
HDB3/AMI
Decoder
Jitter
Attenuator
RCLKn
RDn/RDPn
CVn/RDNn
Peak
Detector
TTIPn
Line
Driver
TRINGn
HDB3/AMI
Encoder
Waveform
Shaper
TCLKn
TDn/TDPn
BPVIn/TDNn
Transmit
All Ones
Figure-17 TAOS with Analog Loopback
2.17 HOST INTERFACE
2.17.1 PARALLEL HOST INTERFACE
The interface is compatible with Motorola and Intel host. Pins
MODE1 and MODE0 are used to select the operating mode of the
parallel host interface. When pin MODE1 is pulled low, the host uses
separate address bus and data bus. When high, multiplexed address/
data bus is used. When pin MODE0 is pulled low, the parallel host interface is configured for Motorola compatible hosts. When pin MODE0 is
pulled high, the parallel host interface is configured for Intel compatible
hosts. See Table-1 Pin Description for more details. The host interface
pins in each operation mode is tabulated in Table-12:
The host interface provides access to read and write the registers in
the device. The interface consists of serial host interface and parallel
host interface. By pulling pin MODE2 to VDDIO/2 or high, the device can
be set to work in serial mode and in parallel mode respectively.
Table-12 Parallel Host Interface Pins
MODE[2:0]
100
101
110
111
Host Interface
Non-multiplexed Motorola interface
Non-multiplexed Intel interface
Multiplexed Motorola interface
Multiplexed Intel interface
Generic Control, Data and Output Pin
CS, ACK, DS, R/W, AS, A[4:0], D[7:0], INT
CS, RDY, WR, RD, ALE, A[4:0], D[7:0], INT
CS, ACK, DS, R/W, AS, AD[7:0], INT
CS, RDY, WR, RD, ALE, AD[7:0], INT
CS
SCLK
SDI
2
2
1
R/W A1 A2 A3 A4 A5 A6 A7 D0 D1 D2 D3 D4 D5 D6 D7
Address/Command Byte
Input Data Byte
D0 D1 D2 D3 D4 D5 D6 D7
SDO
High Impedance
Driven while R/W=1
1. While R/W=1, read from IDT82V2058; While R/W=0, write to IDT82V2058.
2. Ignored.
Figure-18 Serial Host Mode Timing
data byte (D7~D0), as shown in Figure-18. When bit R/W is set to ‘1’,
data is read out from pin SDO. When bit R/W is set to ‘0’, data on pin
SDI is written into the register whose address is indicated by address
bits A5~A1. See Figure-18 Serial Host Mode Timing.
2.17.2 SERIAL HOST INTERFACE
By pulling pin MODE2 to VDDIO/2, the device operates in the serial
host Mode. In this mode, the registers are accessible through a 16-bit
word which contains an 8-bit command/address byte (bit R/W and 5address-bit A1~A5, A6 and A7 bits are ignored) and a subsequent 8-bit
22
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
2.18 INTERRUPT HANDLING
2.18.2 INTERRUPT ENABLE
The IDT82V2058 provides a latched interrupt output (INT) and the
four kinds of interrupts are all reported by this pin. When the Interrupt
Mask register (LOSM, DFM and AISM) is set to ‘1’, the Interrupt Status
register (LOSI, DFI and AISI) is enabled respectively. Whenever there is
a transition (‘0’ to ‘1’ or ‘1’ to ‘0’) in the corresponding status register, the
Interrupt Status register will change into ‘1’, which means an interrupt
occurs, and there will be a high to low transition on INT pin. An external
pull-up resistor of approximately 10 kΩ is required to support the wireOR operation of INT. When any of the three Interrupt Mask registers is
set to ‘0’ (the power-on default value is ‘0’), the corresponding Interrupt
Status register is disabled and the transition on status register is
ignored.
2.18.1 INTERRUPT SOURCES
There are three kinds of interrupt sources:
1. Status change in register LOS. The analog/digital loss of signal
detector continuously monitors the received signal to update the
specific bit in register LOS which indicates presence or absence
of a LOS condition.
2. Status change in register DF. The automatic power driver circuit
continuously monitors the output drivers signal to update the
specific bit in register DFM which indicates presence or absence
of an output driver short circuit condition.
3. Status change in register AIS. The AIS detector monitors the
received signal to update the specific bit in register AIS which
indicates presence or absence of a AIS condition.
2.18.3 INTERRUPT CLEARING
When an interrupt occurs, the Interrupt Status registers: LOSI, DFI
and AISI, are read to identify the interrupt source. These registers will be
cleared to ‘0’ after the corresponding status registers: LOS, DF and AIS
are read. The Status registers will be cleared once the corresponding
conditions are met.
Interrupt Allowed
Pin INT is pulled high when there is no pending interrupt left. The
interrupt handling in the interrupt service routine is showed in Figure-19.
2.19 G.772 MONITORING
No
The eight channels of IDT82V2058 can all be configured to work as
regular transceivers. In applications using only seven channels (channels 1 to 7), channel 0 is configured to non-intrusively monitor any of the
other channels’ inputs or outputs on the line side. The monitoring is nonintrusive per ITU-T G.772. Figure-20 shows the Monitoring Principle.
The receiver path or transmitter path to be monitored is configured by
pins MC[3:0] in hardware mode or by register PMON in host mode.
Interrupt Condition
Exist?
Yes
Read Interrupt Status Register
The monitored signal goes through the clock and data recovery
circuit of channel 0. The monitored clock can output on RCLK0 which
can be used as a timing interfaces derived from E1 signal. The monitored data can be observed digitally at the output pins RCLK0, RD0/
RDP0 and RDN0. LOS detector is still in use in channel 0 for the monitored signal.
Read Corresponding Status
Register
In monitoring mode, channel 0 can be configured in Remote Loopback. The signal which is being monitored will output on TTIP0 and
TRING0. The output signal can then be connected to a standard test
equipment with an E1 electrical interface for non-intrusive monitoring.
Service the Interrupt
Figure-19 Interrupt Service Routine
23
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Channel N ( 7 > N > 1 )
LOS
Detector
RTIPn
Slicer
RRINGn
LOSn
CLK&Data
Recovery
(DPLL)
Jitter
Attenuator
HDB3/
AMI
Decoder
RCLKn
RDn/RDPn
CVn/RDNn
Waveform
Shaper
Jitter
Attenuator
HDB3/
AMI
Encoder
TCLKn
TDn/TDPn
BPVIn/TDNn
Peak
Detector
TTIPn
Line
Driver
TRINGn
Transmit
All Ones
Channel 0
G.772
Monitor
LOS
Detector
RTIP0
Slicer
RRING0
CLK&Data
Recovery
(DPLL)
LOS0
Jitter
Attenuator
TRING0
Line
Driver
RCLK0
RD0/RDP0
CV0/RDN0
Remote
Loopback
Peak
Detector
TTIP0
HDB3/
AMI
Decoder
Waveform
Shaper
Jitter
Attenuator
Transmit
All Ones
Figure-20 Monitoring Principle
24
HDB3/
AMI
Encoder
TCLK0
TD0/TDP0
BPVI0/TDN0
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
3
PROGRAMMING INFORMATION
The Register ADDP, addressed as 11111 or 1F Hex, switches
between primary registers bank and expanded registers bank.
3.1
REGISTER LIST AND MAP
By setting the register ADDP to ‘AAH’, the 5 address bits point to the
expanded register bank, that is, the expanded registers are available. By
clearing register ADDP, the primary registers are available.
There are 21 primary registers (including an Address Pointer Control
Register and 8 expanded registers in the device).
Primary Registers, whose addresses are 10H, 11H, 16H to 1EH, are
reserved. Expanded registers, whose addresses are 08H to 1EH, are
used for test and must be set to ‘0’ (default).
Whatever the control interface is, 5 address bits are used to set the
registers. In non-multiplexed parallel interface mode, the five dedicated
address bits are A[4:0]. In multiplexed parallel interface mode, AD[4:0]
carries the address information. In serial interface mode, A[5:1] are used
to address the register.
Table-13 Primary Register List
Address
Hex
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
Serial Interface A7-A1
XX00000
XX00001
XX00010
XX00011
XX00100
XX00101
XX00110
XX00111
XX01000
XX01001
XX01010
XX01011
XX01100
XX01101
XX01110
XX01111
XX10000
XX10001
XX10010
XX10011
XX10100
XX10101
XX10110
XX10111
XX11000
XX11001
XX11010
XX11011
XX11100
XX11101
XX11110
Parallel Interface A7-A0
XXX00000
XXX00001
XXX00010
XXX00011
XXX00100
XXX00101
XXX00110
XXX00111
XXX01000
XXX01001
XXX01010
XXX01011
XXX01100
XXX01101
XXX01110
XXX01111
XXX10000
XXX10001
XXX10010
XXX10011
XXX10100
XXX10101
XXX10110
XXX10111
XXX11000
XXX11001
XXX11010
XXX11011
XXX11100
XXX11101
XXX11110
1F
XX11111
XXX11111
Register
R/W
ID
ALB
RLB
TAO
LOS
DF
LOSM
DFM
LOSI
DFI
RS
PMON
DLB
LAC
ATAO
GCF
R
R/W
R/W
R/W
R
R
R/W
R/W
R
R
W
R/W
R/W
R/W
R/W
R/W
Explanation
Device ID Register
Analog Loopback Configuration Register
Remote Loopback Configuration Register
Transmit All Ones Configuration Register
Loss of Signal Status Register
Driver Fault Status Register
LOS Interrupt Mask Register
Driver Fault Interrupt Mask Register
LOS Interrupt Status Register
Driver Fault Interrupt Status Register
Software Reset Register
Performance Monitor Configuration Register
Digital Loopback Configuration Register
LOS/AIS Criteria Configuration Register
Automatic TAOS Configuration Register
Global Configuration Register
Reserved
OE
AIS
AISM
AISI
R/W
R
R/W
R
Output Enable Configuration Register
AIS Status Register
AIS Interrupt Mask Register
AIS Interrupt Status Register
Reserved
ADDP
R/W
Address pointer control Register for switching between primary register bank and
expanded register bank
25
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-14 Expanded (Indirect Address Mode) Register List
Address
Register
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Explanation
Hex Serial Interface A7-A1 Parallel Interface A7-A0
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
XX00000
XX00001
XX00010
XX00011
XX00100
XX00101
XX00110
XX00111
XX01000
XX01001
XX01010
XX01011
XX01100
XX01101
XX01110
XX01111
XX10000
XX10001
XX10010
XX10011
XX10100
XX10101
XX10110
XX10111
XX11000
XX11001
XX11010
XX11011
XX11100
XX11101
XX11110
XXX00000
XXX00001
XXX00010
XXX00011
XXX00100
XXX00101
XXX00110
XXX00111
XXX01000
XXX01001
XXX01010
XXX01011
XXX01100
XXX01101
XXX01110
XXX01111
XXX10000
XXX10001
XXX10010
XXX10011
XXX10100
XXX10101
XXX10110
XXX10111
XXX11000
XXX11001
XXX11010
XXX11011
XXX11100
XXX11101
XXX11110
e-SING
e-CODE
e-CRS
e-RPDN
e-TPDN
e-CZER
e-CODV
e-EQUA
1F
XX11111
XXX11111
ADDP
Single Rail Mode Setting Register
Encoder/Decoder Selection Register
Clock Recovery Enable/Disable Register
Receiver n Powerdown Enable/Disable Register
Transmitter n Powerdown Enable/Disable Register
Consecutive Zero Detect Enable/Disable Register
Code Violation Detect Enable/Disable Register
Enable Equalizer Enable/Disable Register
Test
R/W
26
Address pointer control register for switching between primary register bank
and expanded register bank
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-15 Primary Register Map
Register
Address
R/W
Default
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
ID
00H
R
Default
ID 7
R
0
ID 6
R
0
ID 5
R
0
ID 4
R
1
ID 3
R
0
ID 2
R
0
ID 1
R
0
ID 0
R
0
ALB
01H
R/W
Default
ALB 7
R/W
0
ALB 6
R/W
0
ALB 5
R/W
0
ALB 4
R/W
0
ALB 3
R/W
0
ALB 2
R/W
0
ALB 1
R/W
0
ALB 0
R/W
0
RLB
02H
R/W
Default
RLB 7
R/W
0
RLB 6
R/W
0
RLB 5
R/W
0
RLB 4
R/W
0
RLB 3
R/W
0
RLB 2
R/W
0
RLB 1
R/W
0
RLB 0
R/W
0
TAO
03H
R/W
Default
TAO 7
R/W
0
TAO 6
R/W
0
TAO 5
R/W
0
TAO 4
R/W
0
TAO 3
R/W
0
TAO 2
R/W
0
TAO 1
R/W
0
TAO 0
R/W
0
LOS
04H
R
Default
LOS 7
R
0
LOS 6
R
0
LOS 5
R
0
LOS 4
R
0
LOS 3
R
0
LOS 2
R
0
LOS 1
R
0
LOS 0
R
0
DF
05H
R
Default
DF 7
R
0
DF 6
R
0
DF 5
R
0
DF 4
R
0
DF 3
R
0
DF 2
R
0
DF 1
R
0
DF 0
R
0
LOSM
06H
R/W
Default
LOSM 7
R/W
0
LOSM 6
R/W
0
LOSM 5
R/W
0
LOSM 4
R/W
0
LOSM 3
R/W
0
LOSM 2
R/W
0
LOSM 1
R/W
0
LOSM 0
R/W
0
DFM
07H
R/W
Default
DFM 7
R/W
0
DFM 6
R/W
0
DFM 5
R/W
0
DFM 4
R/W
0
DFM 3
R/W
0
DFM 2
R/W
0
DFM 1
R/W
0
DFM 0
R/W
0
LOSI
08H
R
Default
LOSI 7
R
0
LOSI 6
R
0
LOSI 5
R
0
LOSI 4
R
0
LOSI 3
R
0
LOSI 2
R
0
LOSI 1
R
0
LOSI 0
R
0
DFI
09H
R
Default
DFI 7
R
0
DFI 6
R
0
DFI 5
R
0
DFI 4
R
0
DFI 3
R
0
DFI 2
R
0
DFI 1
R
0
DFI 0
R
0
RS
0AH
W
Default
RS 7
W
1
RS 6
W
1
RS 5
W
1
RS 4
W
1
RS 3
W
1
RS 2
W
1
RS 1
W
1
RS 0
W
1
PMON
0BH
R/W
Default
R/W
0
R/W
0
R/W
0
R/W
0
MC 3
R/W
0
MC 2
R/W
0
MC 1
R/W
0
MC 0
R/W
0
DLB
0CH
R/W
Default
DLB 7
R/W
0
DLB 6
R/W
0
DLB 5
R/W
0
DLB 4
R/W
0
DLB 3
R/W
0
DLB 2
R/W
0
DLB 1
R/W
0
DLB 0
R/W
0
LAC
0DH
R/W
Default
LAC 7
R/W
0
LAC 6
R/W
0
LAC 5
R/W
0
LAC 4
R/W
0
LAC 3
R/W
0
LAC 2
R/W
0
LAC 1
R/W
0
LAC 0
R/W
0
ATAO
0EH
R/W
Default
ATAO 7
R/W
0
ATAO 6
R/W
0
ATAO 5
R/W
0
ATAO 4
R/W
0
ATAO 3
R/W
0
ATAO 2
R/W
0
ATAO 1
R/W
0
ATAO 0
R/W
0
GCF
0FH
R/W
Default
R/W
0
AISE
R/W
0
SCPB
R/W
0
CODE
R/W
0
JADP
R/W
0
JABW
R/W
0
JACF 1
R/W
0
JACF 0
R/W
0
27
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-15 Primary Register Map (Continued)
Register
Address
R/W
Default
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
OE
12 Hex
R/W
Default
OE 7
R/W
0
OE 6
R/W
0
OE 5
R/W
0
OE 4
R/W
0
OE 3
R/W
0
OE 2
R/W
0
OE 1
R/W
0
OE 0
R/W
0
AIS
13 Hex
R
Default
AIS 7
R
0
AIS 6
R
0
AIS 5
R
0
AIS 4
R
0
AIS 3
R
0
AIS 2
R
0
AIS 1
R
0
AIS 0
R
0
AISM
14 Hex
R/W
Default
AISM 7
R/W
0
AISM 6
R/W
0
AISM 5
R/W
0
AISM 4
R/W
0
AISM 3
R/W
0
AISM 2
R/W
0
AISM 1
R/W
0
AISM 0
R/W
0
AISI
15 Hex
R
Default
AISI 7
R
0
AISI 6
R
0
AISI 5
R
0
AISI 4
R
0
AISI 3
R
0
AISI 2
R
0
AISI 1
R
0
AISI 0
R
0
ADDP
1F Hex
R/W
Default
ADDP 7
R/W
0
ADDP 6
R/W
0
ADDP 5
R/W
0
ADDP 4
R/W
0
ADDP 3
R/W
0
ADDP 2
R/W
0
ADDP 1
R/W
0
ADDP 0
R/W
0
Table-16 Expanded (Indirect Address Mode) Register Map
Register
e-SING
e-CODE
e-CRS
e-RPDN
e-TPDN
e-CZER
e-CODV
e-EQUA
ADDP
Address
R/W
Default
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
00H
R/W
Default
01H
R/W
Default
02H
R/W
Default
03H
R/W
Default
04H
R/W
Default
05H
R/W
Default
06H
R/W
Default
07H
R/W
Default
1FH
R/W
Default
SING 7
R/W
0
CODE 7
R/W
0
CRS 7
R/W
0
RPDN 7
R/W
0
TPDN 7
R/W
0
CZER 7
R/W
0
CODV 7
R/W
0
EQUA 7
R/W
0
ADDP 7
R/W
0
SING 6
R/W
0
CODE 6
R/W
0
CRS 6
R/W
0
RPDN 6
R/W
0
TPDN 6
R/W
0
CZER 6
R/W
0
CODV 6
R/W
0
EQUA 6
R/W
0
ADDP 6
R/W
0
SING 5
R/W
0
CODE 5
R/W
0
CRS 5
R/W
0
RPDN 5
R/W
0
TPDN 5
R/W
0
CZER 5
R/W
0
CODV 5
R/W
0
EQUA 5
R/W
0
ADDP 5
R/W
0
SING 4
R/W
0
CODE 4
R/W
0
CRS 4
R/W
0
RPDN 4
R/W
0
TPDN 4
R/W
0
CZER 4
R/W
0
CODV 4
R/W
0
EQUA 4
R/W
0
ADDP 4
R/W
0
SING 3
R/W
0
CODE 3
R/W
0
CRS 3
R/W
0
RPDN 3
R/W
0
TPDN 3
R/W
0
CZER 3
R/W
0
CODV 3
R/W
0
EQUA 3
R/W
0
ADDP 3
R/W
0
SING 2
R/W
0
CODE 2
R/W
0
CRS 2
R/W
0
RPDN 2
R/W
0
TPDN 2
R/W
0
CZER 2
R/W
0
CODV 2
R/W
0
EQUA 2
R/W
0
ADDP 2
R/W
0
SING 1
R/W
0
SING 0
R/W
0
CODE 0
R/W
0
CRS 0
R/W
0
RPDN 0
R/W
0
TPDN 0
R/W
0
CZER 0
R/W
0
CODV 0
R/W
0
EQUA 0
R/W
0
ADDP 0
R/W
0
28
CODE 1 R/W
0
CRS 1
R/W
0
RPDN 1
R/W
0
TPDN 1
R/W
0
CZER 1
R/W
0
CODV 1
R/W
0
EQUA 1
R/W
0
ADDP 1
R/W
0
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
3.2
REGISTER DESCRIPTION
3.2.1
PRIMARY REGISTERS
INDUSTRIAL TEMPERATURE RANGES
ID: Device ID Register (R, Address = 00H)
Symbol
Position
Default
ID[7:0]
ID.7-0
10H
Description
An 8-bit word is pre-set into the device as the identification and revision number. This number is different with the functional
changes and is mask programmed.
ALB: Analog Loopback Configuration Register (R/W, Address = 01H)
Symbol
ALB[7:0]
Position
ALB.7-0
Default
00H
Description
0 = Normal operation. (Default)
1 = Analog Loopback enabled.
RLB: Remote Loopback Configuration Register (R/W, Address = 02H)
Symbol
Position
Default
RLB[7:0]
RLB.7-0
00H
Description
0 = Normal operation. (Default)
1 = Remote Loopback enabled.
TAO: Transmit All Ones Configuration Register (R/W, Address = 03H)
Symbol
TAO[7:0]
Position
TAO.7-0
Default
00H
Description
0 = Normal operation. (Default)
1 = Transmit all ones.
LOS: Loss of Signal Status Register (R, Address = 04H)
Symbol
LOS[7:0]
Position
LOS.7-0
Default
00H
Description
0 = Normal operation. (Default)
1 = Loss of signal detected.
DF: Driver Fault Status Register (R, Address = 05H)
Symbol
DF[7:0]
Position
DF.7-0
Default
00H
Description
0 = Normal operation. (Default)
1 = Driver fault detected.
LOSM: Loss of Signal Interrupt Mask Register (R/W, Address = 06H)
Symbol
LOSM[7:0]
Position
LOSM.7-0
Default
00H
Description
0 = LOS interrupt is not allowed. (Default)
1 = LOS interrupt is allowed.
DFM: Driver Fault Interrupt Mask Register (R/W, Address = 07H)
Symbol
DFM[7:0]
Position
DFM.7-0
Default
00H
Description
0 = Driver fault interrupt not allowed. (Default)
1 = Driver fault interrupt allowed.
LOSI: Loss of Signal Interrupt Status Register (R, Address = 08H)
Symbol
Position
Default
LOSI[7:0]
LOSI.7-0
00H
Description
0 = (Default). Or after a LOS read operation.
1 = Any transition on LOSn (Corresponding LOSMn is set to ‘1’).
29
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
DFI: Driver Fault Interrupt Status Register (R, Address = 09H)
Symbol
Position
Default
DFI[7:0]
DFI.7-0
00H
Description
0 = (Default). Or after a DF read operation.
1 = Any transition on DFn (Corresponding DFMn is set to ‘1’).
RS: Software Reset Register (W, Address = 0AH)
Symbol
Position
Default
RS[7:0]
RS.7-0
FFH
Description
Writing to this register will not change the content in this register but initiate a 1 µs reset cycle, which means all the registers
in the device are set to their default values.
PMON: Performance Monitor Configuration Register (R/W, Address = 0BH)
Symbol
Position
Default
-
PMON.7-4
0000
MC[3:0]
PMON.3-0
0000
Description
0 = Normal operation. (Default)
1 = Reserved.
0000 = Normal operation without monitoring (Default)
0001 = Monitor Receiver 1
0010 = Monitor Receiver 2
0011 = Monitor Receiver 3
0100 = Monitor Receiver 4
0101 = Monitor Receiver 5
0110 = Monitor Receiver 6
0111 = Monitor Receiver 7
1000 = Normal operation without monitoring
1001 = Monitor Transmitter 1
1010 = Monitor Transmitter 2
1011 = Monitor Transmitter 3
1100 = Monitor Transmitter 4
1101 = Monitor Transmitter 5
1110 = Monitor Transmitter 6
1111 = Monitor Transmitter 7
DLB: Digital Loopback Configuration Register (R/W, Address = 0CH)
Symbol
DLB[7:0]
Position
DLB.7-0
Default
00H
Description
0 = Normal operation. (Default)
1 = Digital Loopback enabled.
LAC: LOS/AIS Criteria Configuration Register (R/W, Address = 0DH)
Symbol
LAC[7:0]
Position
LAC.7-0
Default
00H
Description
0 = G.775 (Default)
1 = ETSI 300 233
ATAO: Automatic TAOS Configuration Register (R/W, Address = 0EH)
Symbol
Position
Default
ATAO[7:0]
ATAO.7-0
00H
Description
0 = No automatic transmit all ones. (Default)
1 = Automatic transmit all ones to the line side during LOS.
30
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
GCF: Global Configuration Register (R/W, Address = 0FH)
Symbol
Position
Default
-
GCF.7
0
AISE
GCF.6
0
SCPB
GCF.5
0
CODE
GCF.4
0
JADP
GCF.3
0
JABW
GCF.2
0
JACF[1:0]
GCF.1-0
00
Description
0 = Normal operation.
1 = Reserved.
0 = AIS insertion to the system side disabled on LOS.
1 = AIS insertion to the system side enabled on LOS.
0 = Short circuit protection is enabled.
1 = Short circuit protection is disabled.
0 = HDB3 encoder/decoder enabled.
1 = AMI encoder/decoder enabled.
Jitter Attenuator Depth Select
0 = 32-bit FIFO (Default)
1 = 64-bit FIFO
Jitter Transfer Function Bandwidth Select
0 = 1.7 Hz
1 = 6.6 Hz
Jitter Attenuator Configuration
00 = JA not used. (Default)
01 = JA in transmit path
10 = JA not used.
11 = JA in receive path
OE: Output Enable Configuration Register (R/W, Address = 12H)
Symbol
OE[7:0]
Position
OE.7-0
Default
00H
Description
0 = Transmit drivers enabled. (Default)
1 = Transmit drivers in high-Z.
AIS: Alarm Indication Signal Status Register (R, Address = 13H)
Symbol
AIS[7:0]
Position
AIS.7-0
Default
00H
Description
0 = Normal operation. (Default)
1 = AIS detected.
AISM: Alarm Indication Signal Interrupt Mask Register (R/W, Address = 14H)
Symbol
AISM[7:0]
Position
AISM.7-0
Default
00H
Description
0 = AIS interrupt is not allowed. (Default)
1 = AIS interrupt is allowed.
AISI: Alarm Indication Signal Interrupt Status Register (R, Address = 15H)
Symbol
Position
Default
AISI[7:0]
AISI.7-0
00H
Description
0 = (Default), or after an AIS read operation
1 = Any transition on AISn. (Corresponding AISMn is set to ‘1’.)
ADDP: Address Pointer Control Register (R/W, Address = 1F H)
Symbol
Position
Default
ADDP[7:0]
ADDP.7-0
00H
Description
Two kinds of configuration in this register can be set to switch between primary register bank and expanded register bank.
When power up, the address pointer will point to the top address of primary register bank automatically.
00H = The address pointer points to the top address of primary register bank (default).
AAH = The address pointer points to the top address of expanded register bank.
31
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
3.2.2
INDUSTRIAL TEMPERATURE RANGES
EXPANDED REGISTER DESCRIPTION
e-SING: Single Rail Mode Setting Register (R/W, Expanded Address = 00H)
Symbol
Position
Default
SING[7:0]
SING.7-0
00H
Description
0 = Pin TDNn selects single rail mode or dual rail mode. (Default)
1 = Single rail mode enabled (with CRSn=0)
e-CODE: Encoder/Decoder Selection Register (R/W, Expanded Address = 01H)
Symbol
Position
Default
CODE[7:0]
CODE.7-0
00H
Description
CODEn selects AMI or HDB3 encoder/decoder on a per channel basis with SINGn = 1 and CRSn = 0.
0 = HDB3 encoder/decoder enabled. (Default)
1 = AMI encoder/decoder enabled.
e-CRS: Clock Recovery Enable/Disable Selection Register (R/W, Expanded Address = 02H)
Symbol
CRS[7:0]
Position
CRS.7-0
Default
00H
Description
0 = Clock recovery enabled. (Default)
1 = Clock recovery disabled.
e-RPDN: Receiver n Powerdown Register (R/W, Expanded Address = 03H)
Symbol
Position
Default
RPDN[7:0]
RPDN.7-0
00H
Description
0 = Normal operation. (Default)
1 = Receiver n is powered down.
e-TPDN: Transmitter n Powerdown Register (R/W, Expanded Address = 04H)
Symbol
Position
Default
TPDN[7:0]
TPDN.7-0
00H
Description
0 = Normal operation. (Default)
1 = Transmitter n is powered down(1) (the corresponding transmit output driver enters a low power high-Z mode).
1. Transmitter n is powered down when either pin TCLKn is pulled low or TPDNn is set to ‘1’
e-CZER: Consecutive Zero Detect Enable/Disable Register (R/W, Expanded Address = 05H)
Symbol
Position
Default
CZER[7:0]
CZER.7-0
00H
Description
0 = Excessive zeros detect disabled. (Default)
1 = Excessive zeros detect enabled for HDB3 decoder in single rail mode.
e-CODV: Code Violation Detect Enable/Disable Register (R/W, Expanded Address = 06H)
Symbol
Position
Default
CODV[7:0]
CODV.7-0
00H
Description
0 = Code Violation Detect enable for HDB3 decoder in single rail mode. (Default)
1 = Code Violation Detect disabled.
e-EQUA: Receive Equalizer Enable/Disable Register (R/W, Expanded Address = 07H)
Symbol
Position
Default
Description
EQUA[7:0]
EQUA.7-0
00H
0 = Normal operation. (Default)
1 = Equalizer in Receiver n is enabled, which can improve the receive performance when transmission length is more than
200 m.
32
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
4
IEEE STD 1149.1 JTAG TEST
ACCESS PORT
The JTAG boundary scan registers includes BSR (Boundary Scan
Register), IDR (Device Identification Register), BR (Bypass Register)
and IR (Instruction Register). These will be described in the following
pages. Refer to Figure-21 for architecture.
The IDT82V2058 supports the digital Boundary Scan Specification
as described in the IEEE 1149.1 standards.
4.1 JTAG INSTRUCTIONS AND INSTRUCTION REGISTER (IR)
The boundary scan architecture consists of data and instruction
registers plus a Test Access Port (TAP) controller. Control of the TAP is
achieved through signals applied to the TMS and TCK pins. Data is
shifted into the registers via the TDI pin, and shifted out of the registers
via the TDO pin. JTAG test data are clocked at a rate determined by
JTAG test clock.
Digital output pins
The IR with instruction decode block is used to select the test to be
executed or the data register to be accessed or both.
The instructions are shifted in LSB first to this 3-bit register. See
Table-17 Instruction Register Description on page 34 for details of the
codes and the instructions related.
Digital input pins
parallel latched output
BSR (Boundary Scan Register)
MUX
IDR (Device Identification Register)
TDI
MUX
BR (Bypass Register)
IR (Instruction Register)
Control<6:0>
TMS
TRST
TAP
(Test Access Port)
Controller
Select
High-Z Enable
TCK
Figure-21 JTAG Architecture
33
TDO
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-17 Instruction Register Description
IR Code
Instruction
Comments
Extest
The external test instruction allows testing of the interconnection to other devices. When the current instruction is the
EXTEST instruction, the boundary scan register is placed between TDI and TDO. The signal on the input pins can be
sampled by loading the boundary scan register using the Capture-DR state. The sampled values can then be viewed by
shifting the boundary scan register using the Shift-DR state. The signal on the output pins can be controlled by loading
patterns shifted in through input TDI into the boundary scan register using the Update-DR state.
100
Sample/Preload
The sample instruction samples all the device inputs and outputs. For this instruction, the boundary scan register is placed
between TDI and TDO. The normal path between IDT82V2058 logic and the I/O pins is maintained. Primary device
inputs and outputs can be sampled by loading the boundary scan register using the Capture-DR state. The sampled values can then be viewed by shifting the boundary scan register using the Shift-DR state.
110
Idcode
The identification instruction is used to connect the identification register between TDI and TDO. The device's identification code can then be shifted out using the Shift-DR state.
111
Bypass
The bypass instruction shifts data from input TDI to output TDO with one TCK clock period delay. The instruction is used
to bypass the device.
000
4.2.2
Table-18 Device Identification Register Description
4.2
Bit No.
Comments
0
Set to ‘1’
1~11
Producer Number
12~27
Part Number
28~31
Device Revision
BYPASS REGISTER (BR)
The BR consists of a single bit. It can provide a serial path between
the TDI input and TDO output, bypassing the BSR to reduce test access
times.
4.2.3
BOUNDARY SCAN REGISTER (BSR)
The BSR can apply and read test patterns in parallel to or from all the
digital I/O pins. The BSR is a 98 bits long shift register and is initialized
and read using the instruction EXTEST or SAMPLE/PRELOAD. Each
pin is related to one or more bits in the BSR. Please refer to Table-19 for
details of BSR bits and their functions.
JTAG DATA REGISTER
4.2.1 DEVICE IDENTIFICATION REGISTER (IDR)
The IDR can be set to define the producer number, part number and
the device revision, which can be used to verify the proper version or
revision number that has been used in the system under test. The IDR is
32 bits long and is partitioned as in Table-18. Data from the IDR is
shifted out to TDO LSB first.
Table-19 Boundary Scan Register Description
Bit No.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Bit Symbol
POUT0
PIN0
POUT1
PIN1
POUT2
PIN2
POUT3
PIN3
POUT4
PIN4
POUT5
PIN5
POUT6
PIN6
POUT7
PIN7
Pin Signal
LP0
LP0
LP1
LP1
LP2
LP2
LP3
LP3
LP4
LP4
LP5
LP5
LP6
LP6
LP7
LP7
Type
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
Comments
34
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-19 Boundary Scan Register Description (Continued)
Bit No.
Bit Symbol
Pin Signal
Type
16
PIOS
N/A
-
17
18
19
20
21
22
TCLK1
TDP1
TDN1
RCLK1
RDP1
RDN1
TCLK1
TDP1
TDN1
RCLK1
RDP1
RDN1
I
I
I
O
O
O
23
HZEN1
N/A
-
24
25
26
27
28
29
30
LOS1
TCLK0
TDP0
TDN0
RCLK0
RDP0
RDN0
LOS1
TCLK0
TDP0
TDN0
RCLK0
RDP0
RDN0
O
I
I
I
O
O
O
31
HZEN0
N/A
-
32
33
34
35
36
LOS0
MODE1
LOS3
RDN3
RDP3
LOS0
MODE1
LOS3
RDN3
RDP3
O
I
O
O
O
37
HZEN3
N/A
-
38
39
40
41
42
43
44
RCLK3
TDN3
TDP3
TCLK3
LOS2
RDN2
RDP2
RCLK3
TDN3
TDP3
TCLK3
LOS2
RDN2
RDP2
O
I
I
I
O
O
O
45
HZEN2
N/A
-
46
47
48
49
50
51
RCLK2
TDN2
TDP2
TCLK2
INT
ACK
RCLK2
TDN2
TDP2
TCLK2
INT
ACK
O
I
I
I
O
O
52
SDORDYS
N/A
-
53
54
55
56
WRB
RDB
ALE
CSB
DS
R/W
ALE
CS
I
I
I
I
Comments
Controls pins LP[7:0].
When ‘0’, the pins are configured as outputs. The output values to the pins are set in POUT 7~0.
When ‘1’, the pins are high-Z. The input values to the pins are read in PIN 7~0.
Controls pin RDP1, RDN1 and RCLK1.
When ‘0’, the outputs are enabled on the pins.
When ‘1’, the pins are high-Z.
Controls pin RDP0, RDN0 and RCLK0.
When ‘0’, the outputs are enabled on the pins.
When ‘1’, the pins are high-Z.
Controls pin RDP3, RDN3 and RCLK3.
When ‘0’, the outputs are enabled on the pins.
When ‘1’, the pins are high-Z.
Controls pin RDP2, RDN2 and RCLK2.
When ‘0’, the outputs are enabled on the pins.
When ‘1’, the pins are high-Z.
Control pin ACK.
When ‘0’, the output is enabled on pin ACK.
When ‘1’, the pin is high-Z.
35
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-19 Boundary Scan Register Description (Continued)
Bit No.
57
58
59
60
61
62
63
Bit Symbol
MODE0
TCLK5
TDP5
TDN5
RCLK5
RDP5
RDN5
Pin Signal
MODE0
TCLK5
TDP5
TDN5
RCLK5
RDP5
RDN5
Type
I
I
I
I
O
O
O
64
HZEN5
N/A
-
65
66
67
68
69
70
71
LOS5
TCLK4
TDP4
TDN4
RCLK4
RDP4
RDN4
LOS5
TCLK4
TDP4
TDN4
RCLK4
RDP4
RDN4
O
I
I
I
O
O
O
72
HZEN4
N/A
-
73
74
75
76
77
78
LOS4
OE
CLKE
LOS7
RDN7
RDP7
LOS4
OE
CLKE
LOS7
RDN7
RDP7
O
I
I
O
O
O
79
HZEN7
N/A
-
80
81
82
83
84
85
86
RCLK7
TDN7
TDP7
TCLK7
LOS6
RDN6
RDP6
RCLK7
TDN7
TDP7
TCLK7
LOS6
RDN6
RDP6
O
I
I
I
O
O
O
87
HZEN6
N/A
-
88
89
90
91
92
93
94
95
96
97
98
RCLK6
TDN6
TDP6
TCLK6
MCLK
MODE2
A4
A3
A2
A1
A0
RCLK6
TDN6
TDP6
TCLK6
MCLK
MODE2
A4
A3
A2
A1
A0
O
I
I
I
I
I
I
I
I
I
I
Comments
Controls pin RDP5, RDN5 and RCLK5.
When ‘0’, the outputs are enabled on the pins.
When ‘1’, the pins are high-Z.
Controls pin RDP4, RDN4 and RCLK4.
When ‘0’, the outputs are enabled on the pins.
When ‘1’, the pins are high-Z.
Controls pin RDP7, RDN7 and RCLK7.
When ‘0’, the outputs are enabled on the pins.
When ‘1’, the pins are high-Z.
Controls pin RDP6, RDN6 and RCLK6.
When ‘0’, the outputs are enabled on the pins.
When ‘1’, the pins are high-Z.
36
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
4.3
INDUSTRIAL TEMPERATURE RANGES
TEST ACCESS PORT CONTROLLER
instruction registers. The value shown next to each state transition in
this figure states the value present at TMS at each rising edge of TCK.
Refer to Table-20 for details of the state description.
The TAP controller is a 16-state synchronous state machine. Figure22 shows its state diagram A description of each state follows. Note that
the figure contains two main branches to access either the data or
Table-20 TAP Controller State Description
State
Description
Test Logic Reset
In this state, the test logic is disabled. The device is set to normal operation. During initialization, the device initializes the instruction register
with the IDCODE instruction.
Regardless of the original state of the controller, the controller enters the Test-Logic-Reset state when the TMS input is held high for at least 5
rising edges of TCK. The controller remains in this state while TMS is high. The device processor automatically enters this state at power-up.
Run-Test/Idle
This is a controller state between scan operations. Once in this state, the controller remains in the state as long as TMS is held low. The
instruction register and all test data registers retain their previous state. When TMS is high and a rising edge is applied to TCK, the controller
moves to the Select-DR state.
Select-DR-Scan
This is a temporary controller state and the instruction does not change in this state. The test data register selected by the current instruction
retains its previous state. If TMS is held low and a rising edge is applied to TCK when in this state, the controller moves into the Capture-DR
state and a scan sequence for the selected test data register is initiated. If TMS is held high and a rising edge applied to TCK, the controller
moves to the Select-IR-Scan state.
Capture-DR
In this state, the Boundary Scan Register captures input pin data if the current instruction is EXTEST or SAMPLE/PRELOAD. The instruction
does not change in this state. The other test data registers, which do not have parallel input, are not changed. When the TAP controller is in
this state and a rising edge is applied to TCK, the controller enters the Exit1-DR state if TMS is high or the Shift-DR state if TMS is low.
Shift-DR
In this controller state, the test data register connected between TDI and TDO as a result of the current instruction shifts data on stage toward
its serial output on each rising edge of TCK. The instruction does not change in this state. When the TAP controller is in this state and a rising
edge is applied to TCK, the controller enters the Exit1-DR state if TMS is high or remains in the Shift-DR state if TMS is low.
Exit1-DR
This is a temporary state. While in this state, if TMS is held high, a rising edge applied to TCK causes the controller to enter the Update-DR
state, which terminates the scanning process. If TMS is held low and a rising edge is applied to TCK, the controller enters the Pause-DR
state. The test data register selected by the current instruction retains its previous value and the instruction does not change during this state.
Pause-DR
The pause state allows the test controller to temporarily halt the shifting of data through the test data register in the serial path between TDI
and TDO. For example, this state could be used to allow the tester to reload its pin memory from disk during application of a long test
sequence. The test data register selected by the current instruction retains its previous value and the instruction does not change during this
state. The controller remains in this state as long as TMS is low. When TMS goes high and a rising edge is applied to TCK, the controller
moves to the Exit2-DR state.
Exit2-DR
This is a temporary state. While in this state, if TMS is held high, a rising edge applied to TCK causes the controller to enter the Update-DR
state, which terminates the scanning process. If TMS is held low and a rising edge is applied to TCK, the controller enters the Shift-DR state.
The test data register selected by the current instruction retains its previous value and the instruction does not change during this state.
Update-DR
The Boundary Scan Register is provided with a latched parallel output to prevent changes while data is shifted in response to the EXTEST
and SAMPLE/PRELOAD instructions. When the TAP controller is in this state and the Boundary Scan Register is selected, data is latched into
the parallel output of this register from the shift-register path on the falling edge of TCK. The data held at the latched parallel output changes
only in this state. All shift-register stages in the test data register selected by the current instruction retain their previous value and the instruction does not change during this state.
Select-IR-Scan
This is a temporary controller state. The test data register selected by the current instruction retains its previous state. If TMS is held low and
a rising edge is applied to TCK when in this state, the controller moves into the Capture-IR state, and a scan sequence for the instruction register is initiated. If TMS is held high and a rising edge is applied to TCK, the controller moves to the Test-Logic-Reset state. The instruction
does not change during this state.
Capture-IR
In this controller state, the shift register contained in the instruction register loads a fixed value of ‘100’ on the rising edge of TCK. This supports fault-isolation of the board-level serial test data path. Data registers selected by the current instruction retain their value and the instruction does not change during this state. When the controller is in this state and a rising edge is applied to TCK, the controller enters the Exit1IR state if TMS is held high, or the Shift-IR state if TMS is held low.
Shift-IR
In this state, the shift register contained in the instruction register is connected between TDI and TDO and shifts data one stage towards its
serial output on each rising edge of TCK. The test data register selected by the current instruction retains its previous value and the instruction
does not change during this state. When the controller is in this state and a rising edge is applied to TCK, the controller enters the Exit1-IR
state if TMS is held high, or remains in the Shift-IR state if TMS is held low.
37
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Table-20 TAP Controller State Description (Continued)
State
Description
Exit1-IR
This is a temporary state. While in this state, if TMS is held high, a rising edge applied to TCK causes the controller to enter the Update-IR
state, which terminates the scanning process. If TMS is held low and a rising edge is applied to TCK, the controller enters the Pause-IR state.
The test data register selected by the current instruction retains its previous value and the instruction does not change during this state.
Pause-IR
The pause state allows the test controller to temporarily halt the shifting of data through the instruction register. The test data register selected
by the current instruction retains its previous value and the instruction does not change during this state. The controller remains in this state as
long as TMS is low. When TMS goes high and a rising edge is applied to TCK, the controller moves to the Exit2-IR state.
Exit2-IR
This is a temporary state. While in this state, if TMS is held high, a rising edge applied to TCK causes the controller to enter the Update-IR
state, which terminates the scanning process. If TMS is held low and a rising edge is applied to TCK, the controller enters the Shift-IR state.
The test data register selected by the current instruction retains its previous value and the instruction does not change during this state.
Update-IR
The instruction shifted into the instruction register is latched into the parallel output from the shift-register path on the falling edge of TCK.
When the new instruction has been latched, it becomes the current instruction. The test data registers selected by the current instruction
retain their previous value.
1
Test-logic Reset
0
0
Run Test/Idle
1
Select-DR
1
Select-IR
0
1
0
1
Capture-DR
Capture-IR
0
0
0
0
Shift-DR
Shift-IR
1
1
1
Exit1-DR
1
Exit1-IR
0
0
0
0
Pause-DR
Pause-IR
1
0
1
0
Exit2-DR
Exit2-IR
1
1
Update-DR
0
1
Figure-22 JTAG State Diagram
38
1
Update-IR
1
0
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
ABSOLUTE MAXIMUM RATING
Symbol
Parameter
VDDA, VDDD
VDDIO0, VDDIO1
VDDT0-7
Min
Max
Unit
Core Power Supply
-0.5
4.0
V
I/O Power Supply
-0.5
4.0
V
Transmit Power Supply
-0.5
7.0
V
GND-0.5
5.5
V
GND-0.5
VDDA+ 0.5
VDDD+ 0.5
V
V
100
mA
10
mA
±100
mA
Input Voltage, any digital pin
Input Voltage(1), RTIPn pins and RRINGn pins
Vin
ESD Voltage, any pin(2)
Transient Latch-up Current, any pin
2000
Input Current, any digital pin(3)
Iin
V
-10
DC Input Current, any analog pin(3)
Pd
Maximum Power Dissipation in package
1.6
W
Tc
Case Temperature
120
°C
Ts
Storage Temperature
+150
°C
-65
CAUTION: Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
1.
Referenced to ground
2.
Human body model
3.
Constant input current
RECOMMENDED OPERATING CONDITIONS
Symbol
Min
Typ
Max
Unit
Core Power Supply
3.13
3.3
3.47
V
VDDIO
I/O Power Supply
3.13
3.3
3.47
V
VDDT
Transmitter Supply
3.3 V
3.13
3.3
3.47
V
5V
4.75
5.0
5.25
V
25
85
°C
VDDA, VDDD
Parameter
TA
Ambient Operating Temperature
-40
RL
Output load at TTIPn pins and TRINGn pins
25
IVDD
IVDDIO
IVDDT
Average Core Power Supply Current(1)
I/O Power Supply Current
(2)
Average transmitter power supply current, E1 mode
W
40
60
mA
15
25
mA
(1), (3)
75 Ω
50% ones density data:
125
mA
100% ones density data:
220
mA
120 Ω
50% ones density data:
100
mA
100% ones density data:
200
mA
1.
Maximum power and current consumption over the full operating temperature and power supply voltage range. Includes all channels.
2.
Digital output is driving 50 pF load, digital input is within 10% of the supply rails.
3.
Power consumption includes power absorbed by line load and external transmitter components.
39
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
POWER CONSUMPTION
Symbol
Parameter
E1, 3.3 V, 75 Ω Load
50% ones density data:
100% ones density data:
E1, 3.3 V, 120 Ω Load
50% ones density data:
100% ones density data:
E1, 5.0 V, 75 Ω Load
50% ones density data:
100% ones density data:
E1, 5.0 V, 120 Ω Load
50% ones density data:
100% ones density data:
1.
Min
Typ
Max(1)(2)
Unit
-
612
1050
1125
mW
mW
-
526
880
940
mW
mW
-
835
1510
1610
mW
mW
-
710
1240
1330
mW
mW
Maximum power and current consumption over the full operating temperature and power supply voltage range. Includes all channels.
2. Power consumption includes power absorbed by line load and external transmitter components.
DC CHARACTERISTICS
Symbol
VIL
Parameter
Min
Typ
1
--3
MODE2, JAS and LPn pins
VIM
All other digital inputs pins
Input Mid Level Voltage
1
--3
MODE2, JAS and LPn pins
VIH
VDDIO+0.2
MODE2, JAS and LPn pins
2
--- VDDIO+ 0.2
3
All other digital inputs pins
2.0
Output Low level Voltage(1) (Iout = 1.6 mA)
VOH
Output High level Voltage(1) (Iout = 400 µA)
Analog Input Quiescent Voltage (RTIPn/RRINGn pin while floating)
Input High Level Current (MODE2, JAS and LPn pin)
Input Low Level Current (MODE2, JAS and LPn pin)
Input Leakage Current
TMS, TDI and TRST pins
All other digital input pins
High-Z Leakage Current
Output High-Z on TTIPn pins and TRINGn pins
IZL
ZOH
Unit
1
--- VDDIO
2
VDDIO-0.2
V
0.8
V
2
--- VDDIO-0.2
3
V
Input High Voltage
VOL
VMA
IH
IL
II
Max
Input Low Level Voltage
1. Output drivers will output CMOS logic levels into CMOS loads.
40
V
2.4
1.33
-10
-10
150
1.4
0.4
V
V
VDDIO
V
1.47
50
50
V
µA
µA
50
10
10
µA
µA
µA
kΩ
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TRANSMITTER CHARACTERISTICS
Symbol
Parameter
Vo-p
Output Pulse Amplitudes
75 Ω load
120 Ω load
Vo-s
Zero (space) Level
75 Ω load
120 Ω load
Min
Typ
Max
Unit
2.14
2.7
2.37
3.0
2.6
3.3
V
V
-0.237
-0.3
0.237
0.3
V
V
-1
+1
%
200
mV
256
ns
(1)
Transmit Amplitude Variation with supply
Difference between pulse sequences for 17 consecutive pulses
TPW
RTX
JTXP-P
Output Pulse Width at 50% of nominal amplitude
232
Ratio of the amplitudes of Positive and Negative Pulses at the center of the pulse interval
0.95
Transmit Return Loss
75 Ω
51 kHz – 102 kHz
102 kHz – 2.048 MHz
2.048 MHz – 3.072 MHz
15
15
15
dB
dB
dB
120 Ω
51 kHz – 102 kHz
102 kHz – 2.048 MHz
2.048 MHz – 3.072 MHz
15
15
15
dB
dB
dB
Intrinsic Transmit Jitter (TCLK is jitter free, JA enabled)
Line Short Circuit Current(3)
1. Measured at the line output ports
2.
0.050
U.I.
8
3
U.I.
U.I.
180
mAp
Transmit Path Delay (JA is disabled)
Single Rail
Dual Rail
ISC
1.05
(2)
20 Hz – 100 kHz
Td
244
Test at IDT82V2058 evaluation board
3. Measured on device, between TTIPn and TRINGn
41
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
RECEIVER CHARACTERISTICS
Symbol
Parameter
ATT
IA
Permissible Cable Attenuation (@1024 kHz)
Input Amplitude
SIR
Signal to Interference Ratio Margin(1)
Data Decision Threshold (refer to peak input voltage)
Data Slicer Threshold
SRE
JRXp-p
JTRX
ZDM
ZCM
RRX
Min
0.1
Max
Unit
15
0.9
dB
Vp
-15
dB
50
150
Analog Loss Of Signal(2)
Declare/Clear:
Allowable consecutive zeros before LOS
G.775:
ETSI 300 233:
LOS Reset
Clock Recovery Mode
Peak to Peak Intrinsic Receive Jitter (JA disabled)
Jitter Tolerance
1 Hz – 20 Hz
20 Hz – 2.4 kHz
18 kHz – 100 kHz
Receiver Differential Input Impedance
Receiver Common Mode Input Impedance to GND
120/150
200/250
%
mV
280/350
mVp
0.0625
% ones
U.I.
32
2048
12.5
18.0
1.5
0.2
10
U.I.
U.I.
U.I.
kΩ
kΩ
20
20
20
dB
dB
dB
120
Receive Return Loss
51 kHz – 102 kHz
102 kHz – 2.048 MHz
2.048 MHz – 3.072 MHz
Receive Path Delay
Dual rail
Single rail
3
8
1. Per G.703, O.151 @ 6 dB cable attenuation
2.
Typ
U.I.
U.I.
Measured on device, between RTIP and RRING, all ones signal.
JITTER ATTENUATOR CHARACTERISTICS
Symbol
f-3dB
Parameter
Min
Jitter Transfer Function Corner Frequency (–3 dB)
Host mode: 32/64 bit FIFO
JABW = 0:
JABW = 1:
Hardware mode
Typ
Max
1.7
6.6
1.7
Unit
Hz
Hz
Hz
Jitter Attenuator(1)
-0.5
-0.5
+19.5
+19.5
@ 3 Hz
@ 40 Hz
@ 400 Hz
@ 100 kHz
td
Jitter Attenuator Latency Delay
32 bit FIFO:
64 bit FIFO:
Input Jitter Tolerance before FIFO Overflow Or Underflow
32 bit FIFO:
64 bit FIFO:
Output Jitter in Remote Loopback(2)
dB
dB
dB
dB
16
32
U.I.
U.I.
28
56
U.I.
U.I.
U.I.
0.11
1.
Per G.736, see Figure-38 on page 52.
2.
Per ETSI CTR12/13 output jitter.
42
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TRANSCEIVER TIMING CHARACTERISTICS
Symbol
Parameter
Min
Typ
Max
2.048
MCLK Frequency
Unit
MHz
MCLK Tolerance
-100
100
ppm
MCLK Duty Cycle
40
60
%
Transmit path
2.048
TCLK Frequency
MHz
TCLK Tolerance
-50
+50
ppm
TCLK Duty Cycle
10
90
%
t1
Transmit Data Setup Time
40
ns
t2
Transmit Data Hold Time
40
ns
Delay Time of OE Low to Driver High-Z
40
Delay Time of TCLK Low to Driver High-Z
44
1
µs
48
µs
Receive path
Clock Recovery Capture Range(1)
± 80
40
50
60
%
t4
RCLK Pulse Width(2)
457
488
519
ns
t5
RCLK Pulse Width Low Time
203
244
285
ns
t6
RCLK Pulse Width High Time
203
244
285
ns
30
ns
Rise/Fall Time(3)
1.
ppm
RCLK Duty Cycle(2)
5
t7
Receive Data Setup Time
200
244
ns
t8
Receive Data Hold Time
200
244
ns
t9
RDPn/RDNn Pulse Width (MCLK = High)(4)
200
244
ns
Relative to nominal frequency, MCLK = ± 100 ppm
2. RCLK
duty cycle widths will vary depending on extent of received pulse jitter displacement. Maximum and minimum RCLK duty cycles are for worst case jitter conditions (0.2 UI displacement for E1 per ITU G.823).
3.
For all digital outputs. C load = 15 pF
4. Clock recovery is disabled in this mode.
43
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TCLKn
t1
t2
TDn/TDPn
BPVIn/TDNn
Figure-23 Transmit System Interface Timing
t4
RCLKn
t6
t5
t7
t8
RDn/RDPn
(CLKE = 1)
CVn/RDNn
t7
RDn/RDPn
(CLKE = 0)
CVn/RDNn
Figure-24 Receive System Interface Timing
44
t8
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
JTAG TIMING CHARACTERISTICS
Symbol
Parameter
Min
Typ
Max
Unit
t1
TCK Period
200
ns
t2
TMS to TCK setup Time
TDI to TCK Setup Time
50
ns
t3
TCK to TMS Hold Time
TCK to TDI Hold Time
50
ns
t4
TCK to TDO Delay Time
100
t1
TCK
t2
t3
TMS
TDI
t4
TDO
Figure-25 JTAG Interface Timing
45
ns
Comments
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
PARALLEL HOST INTERFACE TIMING CHARACTERISTICS
INTEL MODE READ TIMING CHARACTERISTICS
Symbol
t1
t2
t3
t4
t5
t6
t7
t8
t9
t10
t11
t12
t13
t14
t15
t16
1.
Parameter
Min
Active RD Pulse Width
Active CS to Active RD Setup Time
Inactive RD to Inactive CS Hold Time
Valid Address to Inactive ALE Setup Time (in Multiplexed Mode)
Invalid RD to Address Hold Time (in Non-Multiplexed Mode)
Active RD to Data Output Enable Time
Inactive RD to Data High-Z Delay Time
Active CS to RDY delay time
Inactive CS to RDY High-Z Delay Time
Inactive RD to Inactive INT Delay Time
Address Latch Enable Pulse Width (in Multiplexed Mode)
Address Latch Enable to RD Setup Time (in Multiplexed Mode)
Address Setup time to Valid Data Time (in Non-Multiplexed Mode)
Inactive RD to Active RDY Delay Time
Active RD to Active RDY Delay Time
Inactive ALE to Address Hold Time (in Multiplexed Mode)
The t1 is determined by the start time of the valid data when the RDY signal is not used.
46
90
0
0
5
0
7.5
7.5
6
6
10
0
18
10
30
5
Typ
Max
15
15
12
12
20
32
15
85
Unit
Comments
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
(1)
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
t2
CS
t3
t1
RD
ALE(=1)
t13
t5
ADDRESS
A[4:0]
t6
t7
DATA OUT
D[7:0]
t14
t8
t9
RDY
t15
t10
INT
Figure-26 Non-Multiplexed Intel Mode Read Timing
t2
CS
t3
t1
RD
t11
t12
ALE
t13
t16
t4
AD[7:0]
t6
t7
ADDRESS
DATA OUT
t14
t8
t9
RDY
t15
INT
Figure-27 Multiplexed Intel Mode Read Timing
47
t10
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
INTEL MODE WRITE TIMING CHARACTERISTICS
Symbol
t1
t2
t3
t4
t5
t6
t7
t8
t9
t10
t11
t12
t13
t14
t15
Parameter
Min
Active WR Pulse Width
Active CS to Active WR Setup Time
Inactive WR to Inactive CS Hold Time
Valid Address to Latch Enable Setup Time (in Multiplexed Mode)
Invalid WR to Address Hold Time (in Non-Multiplexed Mode)
Valid Data to Inactive WR Setup Time
Inactive WR to Data Hold Time
Active CS to Inactive RDY Delay Time
Active WR to Active RDY Delay Time
Inactive WR to Inactive RDY Delay Time
Invalid CS to RDY High-Z Delay Time
Address Latch Enable Pulse Width (in Multiplexed Mode)
Inactive ALE to WR Setup Time (in Multiplexed Mode)
Inactive ALE to Address hold time (in Multiplexed Mode)
Address setup time to Inactive WR time (in Non-Multiplexed Mode)
Typ
Max
90
0
0
5
2
5
10
6
30
10
6
10
0
5
5
12
85
15
12
Unit
Comments
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
(1)
1. The t1 can be 15 ns when RDY signal is not used.
CS
t2
t1
t3
WR
ALE(=1)
t15
t5
ADDRESS
A[4:0]
t7
t6
WRITE DATA
D[7:0]
t10
t8
t11
RDY
t9
Figure-28 Non-Multiplexed Intel Mode Write Timing
t2
t3
CS
t1
WR
t12
t13
ALE
t14
t4
AD[7:0]
t6
ADDRESS
t8
t7
WRITE DATA
t11
t9
RDY
t10
Figure-29 Multiplexed Intel Mode Write Timing
48
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
MOTOROLA MODE READ TIMING CHARACTERISTICS
Symbol
t1
t2
t3
t4
t5
t6
t7
t8
t9
t10
t11
t12
t13
t14
Parameter
Min
Active DS Pulse Width
Active CS to Active DS Setup Time
Inactive DS to Inactive CS Hold Time
Valid R/W to Active DS Setup Time
Inactive DS to R/W Hold Time
Valid Address to Active DS Setup Time (in Non-Multiplexed Mode)
Active DS to Address Hold Time (in Non-Multiplexed Mode)
Active DS to Data Valid Delay Time (in Non-Multiplexed Mode)
Active DS to Data Output Enable Time
Inactive DS to Data High-Z Delay Time
Active DS to Active ACK Delay Time
Inactive DS to Inactive ACK Delay Time
Inactive DS to Invalid INT Delay Time
Active AS to Active DS Setup Time (in Multiplexed Mode)
Typ
Max
90
0
0
0
0.5
5
10
20
7.5
7.5
30
10
35
15
15
85
15
20
5
1. The t1 is determined by the start time of the valid data when the ACK signal is not used.
CS
t4
t5
R/W
t1
t2
t3
DS
ALE(=1)
t6
t7
ADDRESS
A[4:0]
t10
t8
DATA OUT
D[7:0]
t9
ACK
t12
t11
t13
INT
Figure-30 Non-Multiplexed Motorola Mode Read Timing
CS
t2
t3
R/W
t1
t4
t5
DS
t14
AS
t6
AD[7:0]
t7
ADDRESS
t8
t9
t10
DATA OUT
t11
t12
ACK
t13
INT
Figure-31 Multiplexed Motorola Mode Read Timing
49
Unit
Comments
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
(1)
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
MOTOROLA MODE WRITE TIMING CHARACTERISTICS
Symbol
t1
t2
t3
t4
t5
t6
t7
t8
t9
t10
t11
t12
t13
Parameter
Min
Active DS Pulse Width
Active CS to Active DS Setup Time
Inactive DS to Inactive CS Hold Time
Valid R/W to Active DS Setup Time
Inactive DS to R/W Hold Time
Valid Address to Active DS Setup Time (in Non-Multiplexed Mode)
Valid DS to Address Hold Time (in Non-Multiplexed Mode)
Valid Data to Inactive DS Setup Time
Inactive DS to Data Hold Time
Active DS to Active ACK Delay Time
Inactive DS to Inactive ACK Delay Time
Active AS to Active DS (in Multiplexed Mode)
Inactive DS to Inactive AS Hold Time ( in Multiplexed Mode)
Typ
Max
90
0
0
10
0
10
10
5
10
30
10
0
15
85
15
1. The t1 can be 15ns when the ACK signal is not used.
CS
t4
t5
R/W
t1
t2
t3
DS
ALE(=1)
t6
t7
ADDRESS
A[4:0]
t8
t9
WRITE DATA
t11
D[7:0]
t10
ACK
Figure-32 Non-Multiplexed Motorola Mode Write Timing
CS
t2
t3
R/W
t4
t1
t5
DS
t12
t13
AS
t6
AD[7:0]
t8
t7
ADDRESS
t9
WRITE DATA
t10
ACK
Figure-33 Multiplexed Motorola Mode Writing Timing
50
t11
Unit
Comments
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
(1)
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
SERIAL HOST INTERFACE TIMING CHARACTERISTICS
Symbol
t1
t2
t3
t4
t5
t6
t7
t8
t9
t10
t11
Parameter
Min
SCLK High Time
SCLK Low Time
Active CS to SCLK Setup Time
Last SCLK Hold Time to Inactive CS Time
CS Idle Time
SDI to SCLK Setup Time
SCLK to SDI Hold Time
Rise/Fall Time (any pin)
SCLK Rise and Fall Time
SCLK to SDO Valid Delay Time
SCLK Falling Edge to SDO High-Z Hold Time (CLKE = 0) or CS Rising
Edge to SDO High-Z Hold Time (CLKE = 1)
Typ
Max
Unit
Comments
100
50
35
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Load = 50 pF
25
25
10
50
50
5
5
25
100
ns
CS
t3
t1
t4
t2
t5
SCLK
t6
SDI
t7
t7
LSB
MSB
LSB
CONTROL BYTE
DATA BYTE
Figure-34 Serial Interface Write Timing
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
SCLK
t10
t4
CS
SDO
0
1
2
3
4
5
t11
7
6
Figure-35 Serial Interface Read Timing with CLKE = 0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
SCLK
CS
t4
t10
t11
SDO
0
1
2
3
4
Figure-36 Serial Interface Read Timing with CLKE = 1
51
5
6
7
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
JITTER TOLERANCE PERFORMANCE
1 10
3
100
G.823
IDT82V2058
Jitter (UI)
18 UI @ 1.8 Hz
10
1.5 UI @ 20 Hz
1
1.5 UI @ 2.4
kHz
0.2 UI @ 18 kHz
0.1
1
10
100
1 10
3
4
1 10
5
1 10
Frequency (Hz)
Test condition: PRBS 2^15-1; Line code rule HDB3 is used.
Figure-37 Jitter Tolerance Performance
JITTER TRANSFER PERFORMANCE
0.5 dB @ 3 Hz 0.5 dB @ 40 Hz
0
IDT82V2058
-20
-19.5 dB @ 20 kHz
f3dB = 6.5 Hz
Gain (dB)
G.736
-19.5 dB @
400 Hz
-40
-60
f3dB = 1.7 Hz
1
10
100
1 10 3
1 104
Frequency (Hz)
Test condition: PRBS 2^15-1; Line code rule HDB3 is used.
Figure-38 Jitter Transfer Performance
52
1 105
IDT82V2058 OCTAL E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
ORDERING INFORMATION
XXXXXXX
Device Type
XX
Package
X
Process/
Temperature
Range
Industrial (-40 °C to +85 °C)
Blank
BB
BBG
DA
DAG
Plastic Ball Grid Array (PBGA, BB160)
Green Plastic Ball Grid Array (PBGA, BBG160)
Thin Quad Flatpack (TQFP, DA144)
Green Thin Quad Flatpack (TQFP, DAG144)
82V2058
E1 Short Haul LIU
DATASHEET DOCUMENT HISTORY
11/04/2001
11/20/2001
11/28/2001
11/29/2001
12/05/2001
01/24/2002
02/21/2002
03/25/2002
04/17/2002
05/07/2002
01/15/2003
04/12/2005
09/14/2009
01/21/2010
pgs. 2, 3, 10, 17
pgs. 5, 6, 11, 13, 16, 17, 24, 26, 31, 38, 39, 40, 50
pgs. 5, 24, 26, 31
pgs. 5
pgs. 9
pgs. 2, 3, 9, 14, 39, 40
pgs. 14, 16, 41
pgs. 1, 2, 52
pgs. 17
pgs. 14, 44, 45, 48
pgs. 1, 52
pgs. 1, 5 to 8, 10, 11, 14, 15, 18, 19, 29, 30, 40 to 43, 47 to 53
pg. 40
pg. 8
for SALES:
1-800-345-7015 or 408-284-8200
fax: 408-284-2775
CORPORATE HEADQUARTERS
6024 Silver Creek Valley Road
San Jose, CA 95138
www.idt.com
IDT and the IDT logo are trademarks of Integrated Device Technology, Inc.
53
for Tech Support:
408-360-1552
email:[email protected]