IDT IDT82V2048BB

IDT82V2048
OCTAL T1/E1 SHORT HAUL
LINE INTERFACE UNIT
FEATURES
♦
♦
♦
♦
♦
♦
♦
Fully integrated octal T1/E1 short haul line interface which
supports 100Ω T1 twisted pair, 120Ω E1 twisted pair and 75Ω
E1 coaxial applications
Selectable single rail or dual rail mode and AMI or HDB3/B8ZS
line encoder/decoder
Built-in transmit pre-equalization meets G.703 & T1.102
Selectable transmit/receive jitter attenuator meets ETSI CTR12/
13, ITU G.736, G.742,G.823 and AT&T Pub 62411 specifications
SONET/SDH optimized jitter attenuator meets ITU G.783 mapping jitter specification
Digital/analog LOS detector meets ITU G.775, ETS 300 233 and
T1.231
♦
♦
♦
♦
♦
♦
♦
♦
♦
ITU G.772 non-intrusive monitoring for in-service testing for
any one of channel1 to channel7
Low impedance transmit drivers with tri-state
Selectable hardware and parallel/serial host interface
Local, remote and inband loopback test functions
Hitless Protection Switching (HPS) for 1 to 1 protection without relays
JTAG boundary scan for board test
3.3V supply with 5V tolerant I/O
Low power consumption
Operating Temperature Range: -40°C to +85°C
Available in 144-pin Thin Quad Flat Pack (TQFP_144_DA) and
160-pin Plastic Ball Grid Array (PBGA) packages
FUNCTIONAL BLOCK DIAGRAM
One of Eight Identical Channels
LOS
Detector
RTIPn
CLK&Data
Recovery
(DPLL)
Slicer
RRINGn
Analog
Loopback
Line
Driver
TRINGn
Jitter
Attenuator
Digital
Loopback
Peak
Detector
TTIPn
LOSn
Waveform
Shaper
B8ZS/
HDB3/AMI
Decoder
Remote
Loopback
Jitter
Attenuator
Control Interface
MCLK
OE
CLKE
MODE[2:0]
CS/JAS
TS2/SCLK/ALE/AS
TS1/RD/R/W
TS0/SDI/WR/DS
SD0/RDY/ACK
INT
LP/D/AD[7:0]
MC/A[4:0]
TCLKn
TDn/TDPn
BPVIn/TDNn
IBLC
Generator
Register
File
JTAG TAP
VDD IO
VDDT
VDDD
VDDA
TRST
TCK
TMS
TDI
TDO
Clock
Generator
IBLC
Detector
AIS
Detector
B8ZS/
HDB3/AMI
Encoder
Transmit
All Ones
G.772
Monitor
RCLKn
RDn/RDPn
CVn/RDNn
Figure - 1. Block Diagram
The IDT logo is a registered trademark of Integrated Device Technology, Inc.
DECEMBER 2003
INDUSTRIAL TEMPERATURE RANGES
1
 2003 Integrated Device Technology, Inc.
DSC-6037/11
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
DESCRIPTION:
INDUSTRIAL TEMPERATURE RANGES
nels. The jitter attenuation performance meets ETSI CTR12/13, ITU
G.736, G.742, G.823, and AT&T Pub 62411 specifications.
The IDT82V2048 offers hardware control mode and software control
mode. Software control mode works with either serial host interface or
parallel host interface. The latter works via an Intel/Motorola compatible
8-bit parallel interface for both multiplexed or non-multiplexed applications. Hardware control mode uses multiplexed pins to select different operation modes when the host interface is not available to the
device.
The IDT82V2048 also provides loopback and JTAG boundary scan
testing functions. Using the integrated monitoring function, the
IDT82V2048 can be configured as a 7-channel transceiver with non-intrusive protected monitoring points.
The IDT82V2048 can be used for SDH/SONET multiplexers, central
office or PBX, digital access cross connects, digital radio base stations,
remote wireless modules and microwave transmission systems.
The IDT82V2048 is a single chip, 8-channel T1/E1 short haul PCM
transceiver with a reference clock of 1.544MHz (T1) or 2.048MHz (E1).
It contains 8 transmitters and 8 receivers.
Both the receivers and transmitters can be programmed to work
either in single rail mode or dual rail mode. AMI or HDB3/B8ZS encoder/
decoder is selectable in single rail mode. Pre-encoded transmit data in
NRZ format can be accepted when the device is configured in dual rail
mode. The receivers perform clock and data recovery by using
integrated digital phase-locked loop. As an option, the raw sliced data
(no retiming) can be output on the receive data pins. Transmit
equalization is implemented with low-impedance output drivers that
provide shaped waveforms to the transformer, guaranteeing template
conformance.
A jitter attenuator is integrated in the IDT82V2048 and can be
switched into either the transmit path or the receive path for all chan-
IDT
82V2048DA
72
71
70
69
68
67
66
65
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
TD7/TDP7
TCLK7
LOS6
CV6/RDN6
RD6/RDP6
RCLK6
BPVI6/TDN6
TD6/TDP6
TCLK6
MCLK
MODE2
A4
MC3/A3
MC2/A2
MC1/A1
MC0/A0
VDDIO
GNDIO
VDDD
GNDD
LP0/D0/AD0
LP1/D1/AD1
LP2/D2/AD2
LP3/D3/AD3
LP4/D4/AD4
LP5/D5/AD5
LP6/D6/AD6
LP7/D7/AD7
TCLK1
TD1/TDP1
BPVI1/TDN1
RCLK1
RD1/RDP1
CV1/RDN1
LOS1
TCLK0
BPVI4/TDN4
RCLK4
RD4/RDP4
CV4/RDN4
LOS4
OE
CLKE
VDDT4
TTIP4
TRING4
GNDT4
RTIP4
RRING4
GNDT5
TRING5
TTIP5
VDDT5
RRING5
RTIP5
VDDT6
TTIP6
TRING6
GNDT6
RTIP6
RRING6
GNDT7
TRING7
TTIP7
VDDT7
RRING7
RTIP7
LOS7
CV7/RDN7
RD7/RDP7
RCLK7
BPVI7/TDN7
108
107
106
105
104
103
102
101
100
99
98
97
96
95
94
93
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
77
76
75
74
73
TD4/TDP4
TCLK4
LOS5
CV5/RDN5
RD5/RDP5
RCLK5
BPVI5/TDN5
TD5/TDP5
TCLK5
TDI
TDO
TCK
TMS
TRST
IC
IC
VDDIO
GNDIO
VDDA
GNDA
MODE0/CODE
CS/JAS
TS2/SCLK/ALE/AS
TS1/RD/R/W
TS0/SDI/WR/DS
SDO/RDY/ACK
INT
TCLK2
TD2/TDP2
BPVI2/TDN2
RCLK2
RD2/RDP2
CV2/RDN2
LOS2
TCLK3
TD3/TDP3
PIN CONFIGURATIONS
Figure - 2a. TQFP Package Pin Assignment
2
BPVI3/TDN3
RCLK3
RD3/RDP3
CV3/RDN3
LOS3
RTIP3
RRING3
VDDT3
TTIP3
TRING3
GNDT3
RRING2
RTIP2
GNDT2
TRING2
TTIP2
VDDT2
RTIP1
RRING1
VDDT1
TTIP1
TRING1
GNDT1
RRING0
RTIP0
GNDT0
TRING0
TTIP0
VDDT0
MODE1
LOS0
CV0/RDN0
RD0/RDP0
RCLK0
BPVI0/TDN0
TD0/TDP0
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
PIN CONFIGURATIONS (CONTINUED)
A
B
C
D
E
F
G
H
J
K
L
M
N
P
1
RCLK
7
TCLK
7
RCLK
6
TCLK
6
MCLK
MC
1
LP
6
LP
7
TCLK
1
RCLK
1
TCLK
0
RCLK
0
1
2
RDP
7
TDP
7
RDP
6
TDP
6
MODE
2
MC
2
LP
0
LP
2
LP
5
MODE
1
TDP
1
RDP
1
TDP
0
RDP
0
2
3
RDN
7
TDN
7
RDN
6
TDN
6
LOS
6
MC
3
MC
0
LP
1
LP
4
LOS
1
TDN
1
RDN
1
TDN
0
RDN
0
3
4
VDDT
7
VDDT
7
VDDT
6
VDDT
6
LOS
7
A4
LP
3
LOS
0
VDDT VDDT VDDT
1
1
0
VDDT
0
4
5
TRING
7
TTIP
7
TRING
6
TTIP
6
TTIP
1
TRING
0
5
6
GNDT GNDT GNDT GNDT
7
7
6
6
GNDT GNDT GNDT GNDT
1
1
0
0
6
7
RTIP RRING
7
7
RTIP
6
RRING
6
IDT
82V2048BB
RRING RTIP
1
1
RRING
0
RTIP
0
7
8
RTIP RRING
4
4
RTIP
5
RRING
5
(Bottom View)
RRING RTIP
2
2
RRING
3
RTIP
3
8
9
GNDT GNDT GNDT GNDT
4
4
5
5
GNDT GNDT GNDT GNDT
2
2
3
3
9
10
TRING
4
TTIP
4
TRING
5
TTIP
5
TTIP
2
11
VDDT
4
VDDT
4
VDDT
5
VDDT
5
LOS
4
TMS
12
RDN
4
TDN
4
RDN
5
TDN
5
LOS
5
TDI
13
RDP
4
TDP
4
RDP
5
TDP
5
CLKE
TDO
14
RCLK
4
TCLK
4
RCLK
5
TCLK
5
OE
TCK
A
B
C
D
E
F
VDDIO VDDD
GNDIO GNDD
TRING
1
TRING
2
TTIP
0
TTIP
3
TRING
3
10
VDDT VDDT VDDT
2
2
3
VDDT
3
11
GNDIO GNDA
CS
LOS
3
TRST
MODE
0
TS
2
LOS
2
TDN
2
RDN
2
TDN
3
RDN
3
12
IC
IC
TS
1
INT
TDP
2
RDP
2
TDP
3
RDP
3
13
TS
0
SDO
TCLK
2
RCLK
2
TCLK
3
RCLK
3
14
J
K
L
M
N
P
VDDIO VDDA
G
H
Figure - 2b. PBGA160 Package Pin Assignment
3
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
PIN DESCRIPTION
Name
TTIP0
TTIP1
TTIP2
TTIP3
TTIP4
TTIP5
TTIP6
TTIP7
TRING0
TRING1
TRING2
TRING3
TRING4
TRING5
TRING6
TRING7
RTIP0
RTIP1
RTIP2
RTIP3
RTIP4
RTIP5
RTIP6
RTIP7
RRING0
RRING1
RRING2
RRING3
RRING4
RRING5
RRING6
RRING7
1
Type
Analog
Output
Analog
Input
Pin No.
QFP144 BGA160
45
52
57
64
117
124
129
136
N5
L5
L10
N10
B10
D10
D5
B5
46
51
58
63
118
123
130
135
48
55
60
67
120
127
132
139
P5
M5
M10
P10
A10
C10
C5
A5
P7
M7
M8
P8
A8
C8
C7
A7
49
54
61
66
121
126
133
138
N7
L7
L8
N8
B8
D8
D7
B7
Description
Transmit and Receive Line Interface
TTIPn/TRINGn: Transmit Bipolar Tip/Ring for Channel 0~7
These pins are the differential line driver outputs. They will be in high impedance state if pin OE
is low or the corresponding pin TCLKn is low (pin OE is globe control, while pin TCLKn is perchannel control). In host mode, each pin can be in high impedance state by programming a “1” to
the corresponding bit in Register OE1.
RTIPn/RRINGn: Receive Bipolar Tip/Ring for Channel 0~7
These pins are the differential line receiver inputs.
Register name is indicated by bold capital letter. OE: Output Enable Register.
4
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
PIN DESCRIPTION (CONTINUED)
Name
Type
TD0/TDP0
TD1/TDP1
TD2/TDP2
TD3/TDP3
TD4/TDP4
TD5/TDP5
TD6/TDP6
TD7/TDP7
Pin No.
QFP144 BGA160
N2
37
L2
30
L13
80
N13
73
B13
108
D13
101
D2
8
B2
1
I
38
31
79
72
109
102
7
144
BPVI0/TDN0
BPVI1/TDN1
BPVI2/TDN2
BPVI3/TDN3
BPVI4/TDN4
BPVI5/TDN5
BPVI6/TDN6
BPVI7/TDN7
TCLK0
TCLK1
TCLK2
TCLK3
TCLK4
TCLK5
TCLK6
TCLK7
I
36
29
81
74
107
100
9
2
N3
L3
L12
N12
B12
D12
D3
B3
N1
L1
L14
N14
B14
D14
D1
B1
Description
TDn: Transmit Data for Channel 0~7
When the device is in Single Rail Mode, the NRZ data to be transmitted is input on this pin. Data on
TDn is sampled into the device on falling edges of TCLKn, and encoded by AMI or HDB3/B8ZS line
code rules before being transmitted to the line.
BPVIn: Bipolar Violation Insertion for Channel 0~7
Bipolar violation insertion is available in Single Rail Mode 2 (see table-1) with AMI enabled. A low-tohigh transition on this pin will make the next logic one to be transmitted on TDn the same polarity as the
previous pulse, and violate the AMI rule. This is for testing.
TDPn/TDNn: Positive/Negative Transmit Data for Channel 0~7
When the device is in Dual Rail Mode, the NRZ data to be transmitted for positive/negative pulse is input
on this pin. Data on TDPn/TDNn are active high and sampled on falling edge of TCLKn. The line code in
dual rail mode is as the follows :
TDPn
TDNn
Output Pulse
0
0
Space
0
1
Negative Pulse
1
0
Positive Pulse
1
1
Space
Pulling pin TDNn high for more than 16 consecutive TCLK clock cycles will configure the corresponding
channel into single rail mode 1 (see table-1 on Page14).
TCLKn: Transmit Clock for Channel 0~7
The clock of 1.544 MHz (for T1 mode) or 2.048 MHz (for E1 mode) for transmit is input on this pin. The
transmit data at TDn/TDPn or TDNn is sampled into the device on falling edge of TCLKn.
Pulling TCLKn high for more than 16 MCLK cycles, the corresponding transmitter is set in Transmit All
One (TAO) state (when MCLK is clocked). In TAO state, the TAO generator adopts MCLK as the time
reference.
If TCLKn is Low, the corresponding transmit channel is set into power down state, while driver output
ports become high impedance.
Different combinations of TCLKn and MCLK result in different transmit mode. It is summarized as the
follows:
MCLK
TCLKn
Transmitter Mode
Clocked
Clocked
Normal operation
Clocked
High ( ≥ 16 MCLK) Transmit All One (TAO) signals to the line side in the
corresponding transmit channel.
Clocked
Low (≥ 64 MCLK) Corresponding transmit channel is set into power down state.
High/Low
TCLK1 is clocked TCLKn is clocked Normal operation
TCLKn is high
Transmit All One (TAO) signals to the line side
in the corresponding transmit channel.
(≥ 16 TCLK1)
TCLKn is low
Corresponding transmit channel is set into
power down state.
(≥ 64 TCLK1)
The receive path is not affected by the status of TCLK1. When
MCLK is high, all receive paths just slice the incoming data stream.
When MCLK is low, all the receive paths are powered down.
High/Low
TCLK1 is not
All eight transmitters (TTIPn & TRINGn) will be in high impedance
available
state.
(High/Low)
5
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
PIN DESCRIPTION (CONTINUED)
Pin No.
QFP144 BGA160
P2
RD0/RDP0
O
40
M2
RD1/RDP1
33
M13
RD2/RDP2 Tri-state
77
P13
RD3/RDP3
70
A13
111
RD4/RDP4
C13
104
RD5/RDP5
C2
5
RD6/RDP6
A2
142
RD7/RDP7
Name
Type
CV0/RDN0
CV1/RDN1
CV2/RDN2
CV3/RDN3
CV4/RDN4
CV5/RDN5
CV6/RDN6
CV7/RDN7
RCLK0
RCLK1
RCLK2
RCLK3
RCLK4
RCLK5
RCLK6
RCLK7
MCLK
LOS0
LOS1
LOS2
LOS3
LOS4
LOS5
LOS6
LOS7
O
Tri-state
I
O
41
34
76
69
112
105
4
141
P3
M3
M12
P12
A12
C12
C3
A3
39
32
78
71
110
103
6
143
10
P1
M1
M14
P14
A14
C14
C1
A1
E1
42
35
75
68
113
106
3
140
K4
K3
K12
K11
E11
E12
E3
E4
Description
RDn: Receive Data for Channel 0~7
In Single Rail Mode, the received NRZ data is output on this pin. The data is decoded by AMI or
HDB3/B8ZS line code rule.
CVn: Code Violation for Channel 0~7
In Single Rail Mode, the bipolar violation, code violation and excessive zeros will be reported by driving
pin CVn to high level for a full clock cycle. However, only bipolar violation is indicated when AMI
decoder is selected.
RDPn/RDNn: Positive/Negative Receive Data for Channel 0~7
In Dual Rail Mode with clock recovery, these pins output the NRZ data. A high signal on RDPn
indicates the receipt of a positive pulse on RTIPn/RRINGn while a high signal on RDNn indicates the
receipt of a negative pulse on RTIPn/RRINGn.
The output data at RDn or RDPn/RDNn are valid on the falling edges of RCLK when the CLKE input is
in High level, or valid on the rising edges of RCLK when CLKE is Low.
In Dual Rail Mode without clock recovery, these pins output ht e raw RZ sliced data. In this data
recovery mode, the active polarity of RDPn/RDNn is determined by pin CLKE. When pin CLKE is Low,
RDPn/RDNn is active low. When pin CLKE is High, RDPn/RDNn is active high.
In hardware mode, RDn or RDPn/RDNn will remain active during LOS. In host mode, these pins will
either remain active or insert alarm indication signal (AIS) into the receive path, determined by bit AISE
in register GCF (Global Configuration register).
RDn or RDPn/RDNn is set into high impedance when the corresponding receiver is power down.
RCLKn: Receive Clock for Channel 0~7
In clock recovery mode, this pin outputs the recovered clock from signal received on RTIPn/RRINGn.
The received data are clocked out of the device on rising edges of RCLKn if pin CLKE is low, or on
falling edges of RCLKn if pin CLKE is high.
In data recovery mode, RCLKn is the output of an internal exclusive OR (XOR) which is connected with
RDPn and RDNn. The clock is recovered from the signal on RCLKn externally.
If receiver n is power down, the corresponding RCLKn is in high impedance.
MCLK: Master Clock
This is the independent, free running reference clock. A clock of 1.544 MHz (for T1 mode) or 2.048
MHz (for E1 mode) is supplied to this pin as the clock reference of the device for normal operation.
In receive path, when MCLK is high, the device slices the incoming bipolar line signal into RZ pulse
(Data Recovery mode). When MCLK is low, all the receivers are power down, and the output pins
RCLKn, RDPn and RDNn are switched to high impedance.
In transmit path, the operation mode is decided by the combination of MCLK and TCLKn (see TCLKn
pin description for detail).
Note that wait state generation via RDY/ACK is not available if MCLK is not provided.
LOSn: Loss of Signal Output for Channel 0~7
A high level on this pin indicates the loss of signal when there is no transition over a specified period of
time and no enough ones density in the received signal. The transition will return to low automatically
when there is enough transitions over a specified period of time with a certain ones density in the
received signal. The LOS assertion and desertion criteria are described in the Functional Description.
6
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
PIN DESCRIPTION (CONTINUED)
Name
Type
MODE2
I
Pin No.
QFP144 BGA160
11
E2
(Pulled to
VDDIO / 2)
MODE1
I
43
K2
MODE0
/CODE
I
88
H12
Description
Hardware/Host Control Mode
MODE2: Control Mode Select 2
The signal on this pin determines which control mode is selected to control the device:
MODE2
Control Interface
Low
Control by Hardware mode
VDDIO/2
Control by Serial Host Interface
High
Control by Parallel Host Interface
Hardware control pins include MODE[2:0], TS[2:0], LOOP[7:0], CODE, CLKE, JAS and OE.
Serial host Interface pins include CS, SCLK, SDI, SDO and INT .
Parallel host Interface pins include CS, A[4:0], D[7:0], WR/DS, RD/R/W, ALE/AS, INT and
RDY/ACK. The device supports multiple parallel host interface as follows (refer to MODE1 and
MODE0 pin descriptions below for details):
MODE[2:0]
Host Interface
100
Non-multiplexed Motorola mode interface.
101
Non-multiplexed Intel mode interface.
110
Multiplexed Motorola mode interface.
111
Multiplexed Intel mode interface.
MODE1: Control Mode Select 1
In parallel host mode, the parallel interface operates with separate address bus and data bus
when this pin is Low, and operates with multiplexed address and data bus when this pin is High.
In serial host mode or hardware mode, this pin should be grounded.
MODE0: Control Mode Select 0
In host mode, the parallel host interface is configured for Motorola compatible hosts when this
pin is Low, or for Intel compatible hosts when this pin is High.
CODE: Line Code Rule Select
In hardware control mode, the B8ZS (for T1 mode)/ HDB3 (for E1 mode) encoder/decoder is
enabled when this pin is Low, and AMI encoder/decoder is enabled when this pin is High. The
selections affect all the channels.
CS/JAS
I
(Pulled to
VDDIO / 2)
87
J11
In serial host mode, this pin should be grounded.
CS: Chip Select (Active Low)
In host mode, this pin is asserted low by the host to enable host interface. A transition from
High to Low must occur on this pin for each Read/Write operation and the level must not return
to High until the operation is over.
JAS: Jitter Attenuator Select
In hardware control mode, this pin globally determines the Jitter Attenuator position:
JAS
Jitter Attenuator (JA) Configuration
Low
JA in transmit path
VDDIO/2
JA not used
High
JA in receive path
7
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
PIN DESCRIPTION (CONTINUED)
Name Type
TS2/
SCLK/
ALE/AS
I
Pin No.
Description
QFP144 BGA160
86
J12 TS2: Template Select 2
In hardware control mode, the signal on this pin is the most significant bit for the transmit template select.
Refer to Transmit Template of the Functional Description for details.
SCLK: Shift Clock
In serial host mode, the signal on this pin is the shift clock for the serial interface. Data on pin SDO is
clocked out on falling edges of SCLK if pin CLKE is Low, or on rising edges of SCLK if pin CLKE is High.
Data on pin SDI is always sampled on rising edges of SCLK.
ALE: Address Latch Enable
In parallel Intel multiplexed host mode, the address on AD[4:0] is sampled into the device on falling edges
of ALE (signals on AD[7:5] are ignored). In non-multiplexed host mode, ALE should be pulled High.
TS1/RD
/R/W
I
85
J13
AS: Address Strobe (Active Low)
In parallel Motorola multiplexed host mode, the address on AD[4:0] is latched into the device on falling
edges of AS (signals on AD[7:5] are ignored). In non-multiplexed host mode, AS should be pulled High.
TS1: Template Select 1
In hardware control mode, the signal on this pin is the second most significant bit for the transmit template
select. Refer to Transmit Template of Functional Description for details.
RD: Read Strobe (Active Low)
In parallel Intel multiplexed or non-multiplexed host mode, this pin is active low for read operation.
TS0/
SDI/WR
/DS
I
84
J14
R/W: Read/Write Select
In parallel Motorola multiplexed or non-multiplexed host mode, the pin is active low for write operation and
high for read operation.
TS0: Template Select 0
In hardware control mode, the signal on this pin is the least significant bit for the transmit template select.
Refer to Transmit Template of Functional Description for details.
SDI: Serial Data Input
In serial host mode, this pin input the data to the serial interface. Data on this pin is sampled on rising
edges of SCLK.
WR: Write Strobe (Active Low)
In parallel Intel host mode, this pin is active low during write operation. The data on D[7:0] (in nonmultiplexed mode) or AD[7:0] (in multiplexed mode) is sampled into the device on rising edges of WR.
DS: Data Strobe (Active Low)
In parallel Motorola host mode, this pin is active low. During a write operation (R/W = 0), the data on D[7:0]
(in non-multiplexed mode) or AD[7:0] (in multiplexed mode) is sampled into the device on rising edges of
DS. During a read operation (R/W = 1), the data is driven to D[7:0] (in non-multiplexed mode) or AD[7:0] (in
multiplexed mode) by the device on rising edges of DS.
In parallel Motorola non-multiplexed host mode, the address information on the 5 bits of address bus A[4:0]
are latched into the device on the falling edge of DS.
8
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
PIN DESCRIPTION (CONTINUED)
Name
Type
SDO
/RDY
/ACK
O
Pin No.
Description
QFP144 BGA160
83
K14 SDO: Serial Data Output
In serial host mode, the data is output on this pin. In serial write operation, SDO is always in High
impedance. In serial read operation, SDO is in High impedance only when SDI is in
address/command byte. Data on pin SDO is clocked out of the device on falling edges of SCLK if
pin CLKE is Low, or on rising edges of SCLK if pin CLKE is High.
RDY: Ready Output
In parallel Intel host mode, the high level of this pin reports to the host that bus cycle can be
completed, while low reports the host must insert wait states.
INT
O
Open
Drain
I/O
LP7/D7/AD7
LP6/D6/AD6
LP5/D5/AD5
LP4/D4/AD4 Tri-state
LP3/D3/AD3
LP2/D2/AD2
LP1/D1/AD1
LP0/D0/AD0
82
K13
28
27
26
25
24
23
22
21
K1
J1
J2
J3
J4
H2
H3
G2
ACK : Acknowledge Output (Active Low)
In parallel Motorola host mode, the low level of this pin indicates that valid information on the data
bus is ready for a read operation or acknowledges the acceptance of the written data during a
write operation.
INT : Interrupt (Active Low)
This is the open drain, active low interrupt output. Four sources may cause the interrupt (refer to
Interrupt Handling of Functional Description for details).
LPn: Loopback Select 7~0
In hardware control mode, pin LPn configures the corresponding channel in different loopback
mode, as follows:
LPn
Loopback Configuration
Low
Remote loopback.
VDDIO/2
No loopback.
High
Analog loopback.
Refer to Loopback Configuration of Functional Description for details.
Dn: Data Bus 7~0
In non-multiplexed host mode, these pins are the bi-directional data bus.
ADn: Address/Data Bus 7~0
In multiplexed host mode, these pins are the multiplexed bi-directional address/data bus.
In serial host mode, these pins should be grounded.
9
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
PIN DESCRIPTION (CONTINUED)
Name
Type
A4
MC3/A3
MC2/A2
MC1/A1
MC0/A0
I
Pin No.
QFP144 BGA160
F4
12
F3
13
F2
14
F1
15
G3
16
OE
I
114
E14
CLKE
I
115
E13
Description
MCn: Performance Monitor Configuration 4~0
In hardware control mode, A4 must be connected to GND. MC[3:0] are used to select one
transmitter or receiver of the channel 1 to 7 for non-intrusive monitoring. Channel 0 is used as
the monitoring channel. If a transmitter is monitored, signals on the corresponding pins TTIPn
and TRINGn are internally transmitted to RTIP0 and RRING0. If a receiver is monitored, signals
on the corresponding pins RTIPn and RRINGn are internally transmitted to RTIP0 and RRING0.
The clock and data recovery circuit in receiver 0 can then output the monitored clock to pin
RCLK0 as well as the monitored data to RDP0 and RDN0 pins. The signals monitored by
channel 0 can be routed to TTIP0/TRING0 by activating the remote loopback in this channel.
Performance Monitor Configuration determined by MC[3:0] is shown below. Note that if
MC[2:0] = 000, the device is in normal operation of all the channels.
MC[3:0]
Monitoring Configuration
0000
Normal operation without monitoring.
0001
Monitoring receiver 1.
0010
Monitoring receiver 2.
0011
Monitoring receiver 3.
0100
Monitoring receiver 4.
0101
Monitoring receiver 5.
0110
Monitoring receiver 6.
0111
Monitoring receiver 7.
1000
Normal operation without monitoring.
1001
Monitoring transmitter 1.
1010
Monitoring transmitter 2.
1011
Monitoring transmitter 3.
1100
Monitoring transmitter 4.
1101
Monitoring transmitter 5.
1110
Monitoring transmitter 6.
1111
Monitoring transmitter 7.
An: Address Bus 4~0
When pin MODE1 is low, the parallel host interface operates with separate address and data
bus. In this mode, the signal on this pin is the address bus of the host interface.
OE: Output Driver Enable
Pulling this pin to low can make all driver output into high impedance state immediately for
redundancy application without external mechanical relays. In this condition, all the other
internal circuits remain active.
CLKE: Clock Edge Select
The signal on this pin determines the active edge of RCLKn and SCLK in clock recovery mode,
or determines the active level of RDPn and RDNn in the data recovery mode. (Refer to
Functional Description and Table-2).
10
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
PIN DESCRIPTION (CONTINUED)
Pin No.
QFP144 BGA160
Name
Type
TRST
I
95
G12
TMS
Pullup
I
96
F11
TCK
Pullup
I
97
F14
TDO
O
98
F13
99
F12
Tri-state
TDI
I
Pull up
IC
-
93
G13
IC
-
94
H13
VDDIO
-
GNDIO
-
VDDT0
VDDT1
VDDT2
VDDT3
VDDT4
VDDT5
VDDT6
VDDT7
GNDT0
GNDT1
GNDT2
GNDT3
GNDT4
GNDT5
GNDT6
GNDT7
VDDD
VDDA
GNDD
GNDA
-
17
92
18
91
44
53
56
65
116
125
128
137
47
50
59
62
119
122
131
134
19
90
20
89
G1
G14
G4
G11
N4,P4
L4,M4
L11,M11
N11,P11
A11,B11
C11,D11
C4,D4
A4,B4
N6,P6
L6,M6
L9,M9
N9,P9
A9,B9
C9,D9
C6,D6
A6,B6
H1
H14
H4
H11
-
-
Description
JTAG Signals
TRST: JTAG Test Port Reset (Active Low)
This is the active low asynchronous reset to the JTAG Test Port. This pin has an internal pullup
resistor and it can be left disconnected.
TMS: JTAG Test Mode Select
The signal on this pin controls the JTAG test performance and is clocked into the device on rising
edges of TCK. This pin has an internal pullup resistor and it can be left disconnected.
TCK: JTAG Test Clock
This pin input the clock of the JTAG Test. The data on TDI and TMS are clocked into the device on
rising edges of TCK, while the data on TDO is clocked out of the device on falling edges of TCK.
TDO: JTAG Test Data Output
This pin output the serial data of the JTAG Test. The data on TDO is clocked out of the device on
falling edges of TCK. TDO is a Tri-state output signal. It is active only when scanning of data is
out.
TDI: JTAG Test Data Input
This pin input the serial data of the JTAG Test. The data on TDI is clocked into the device on rising
edges of TCK. This pin has an internal pullup resistor and it can be left disconnected.
IC: Internal Connected
(Leave it open for normal operation.)
IC: Internal Connected
(Leave it open for normal operation.)
Supplies and Grounds
3.3V I/O Power Supply
I/O GND
3.3V / 5V Power Supply for Transmitter Driver
All VDDT pins must be connected to either 3.3V or 5V. It is not allowed to leave any of the VDDT
pins open (not-connected) even if the channel is not used.
Analog GND for Transmitter Driver
3.3V Digital / Analog Core Power Supply
Digital / Analog Core GND
11
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
FUNCTIONAL DESCRIPTION
Therefore, each signal pin on system side has multiple functions
depending on which operation mode the device is in.
The Dual Rail interface consists of TDPn 1, TDNn, TCLKn, RDPn,
RDNn and RCLKn. Data transmitted from TDPn and TDNn appears on
TTIPn and TRINGn at the line interface; data received from the RTIPn
and RRINGn at the line interface are transferred to RDPn and RDNn
while the recovered clock extracting from the received data stream
outputs on RCLKn. In Dual Rail operation, the clock/data recovery mode
is selectable. Dual Rail interface with clock recovery shown in Figure-3
is a default configuration mode. Dual Rail interface with data recovery is
shown in Figure-4. Pin RDPn and RDNn, in this condition, are raw RZ
slice output and internally connected to an EXOR which is fed to the
RCLKn output for external clock recovery applications.
In Single Rail Mode, data transmitted from TDn appears on TTIPn
and TRINGn at the line interface. Data received from the RTIPn and
RRINGn at the line interface appears on RDn while the recovered clock
extracting from the received data stream outputs on RCLKn. When the
device is in single rail interface, the selectable AMI or HDB3/B8ZS line
encoder/decoder is available and any code violation in the received data
will be indicated at the CVn pin. The Single Rail Mode can be devided
into 2 sub-modes. Single Rail Mode 1, whose interface is composed of
TDn, TCLKn, RDn, CVn and RCLKn, is realized by pulling pin TDNn to
high for more than 16 consecutive TCLK cycles. Single Rail Mode 2,
whose interface is composed of TDn, TCLKn, RDn, CVn, RCLKn and
BPVIn, is realized by setting bit CRS in e-CRS2 and bit SING in e-SING.
The difference between them is that, in the latter mode bipolar violation
can be inserted via pin BPVIn if AMI line code is selected.
The configuration of different system interface is summarized in
Table-1.
OVERVIEW
The IDT82V2048 is a fully integrated octal short-haul line interface
unit, which contains eight transmit and receive channels for use in either
E1 or T1 applications. The receiver performs clock and data recovery.
As an option, the raw sliced data (no retiming) can be output to the system. Transmit equalization is implemented with low-impedance output
drivers that provide shaped waveforms to the transformer, guaranteeing
template conformance. A selectable jitter attenuation may be placed in
the receive path or the transmit path. Moreover, multiple testing functions, such as error detection, loopback and JTAG boundary scan are
also provided. The device is optimized for flexible software control
through a serial or parallel host mode interface. Hardware control is also
available. Figure-1 shows One of the Eight Identical Channels operation.
T1 / E1 MODE SELECTION
T1/E1 mode selection configures the device globally. In Hardware
Mode, the template selection pins: TS2, TS1 and TS0 determine
whether the operation mode is T1 or E1 (refer to Table-7). In Software
Mode, the Transmit Template Select Register (Primary Register: 11Hex)
determines whether the operation mode is T1 or E1.
SYSTEM INTERFACE
The system interface of each channel can be configured to operate
in different modes:
1. Single Rail interface with clock recovery.
2. Dual Rail interface with clock recovery.
3. Dual Rail interface with data recovery (that is, with raw data slicing
only and without clock recovery).
LOS
Detector
RTIPn
Slicer
RRINGn
INDUSTRIAL TEMPERATURE RANGES
One of Eight Identical Channels
LOSn
CLK&Data
Recovery
(DPLL)
Jitter
Attenuator
B8ZS/
HDB3/AMI
Decoder
RCLKn
RDPn
RDNn
Waveform
Shaper
Jitter
Attenuator
B8ZS/
HDB3/AMI
Encoder
TCLKn
TDPn
TDNn
Peak
Detector
TTIPn
TRINGn
Line
Driver
Transmit
All Ones
Figure - 3. Dual Rail Interface with Clock Recovery 3
NOTE:
1. The footprint ‘n’ (n = 0 - 7) indicates one of the eight channels
2. The first letter “e-”indicates expanded register.
3. The grey blocks are bypassed and the dotted blocks are selectable
12
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
LOS
Detector
RTIPn
Slicer
RRINGn
INDUSTRIAL TEMPERATURE RANGES
One of Eight Identical Channels
LOSn
CLK&Data
Recovery
(DPLL)
Jitter
Attenuator
B8ZS/
HDB3/AMI
Decoder
Waveform
Shaper
Jitter
Attenuator
B8ZS/
HDB3/AMI
Encoder
RCLKn
(RDP RDN)
RDPn
RDNn
Peak
Detector
TTIPn
Line
Driver
TRINGn
TCLKn
TDPn
TDNn
Transmit
All Ones
Figure - 4. Dual Rail Interface with Data Recovery
One of Eight Identical Channels
LOS
Detector
RTIPn
Slicer
RRINGn
LOSn
CLK&Data
Recovery
(DPLL)
Jitter
Attenuator
HDB3/
B8ZS/AMI
Decoder
Waveform
Shaper
Jitter
Attenuator
HDB3/
B8ZS/AMI
Encoder
RCLKn
RDn
CVn
Peak
Detector
TTIPn
TRINGn
Line
Driver
Transmit
All Ones
Figure - 6. Single Rail Mode
13
TCLKn
TDn
TDNn/BPVIn
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TABLE - 1a. SYSTEM INTERFACE CONFIGURATION (Hardware Mode)
Hardware Mode
MCLK
clocked
clocked
H
L
TDNn
H ( 16 MCLK)
pulse
pulse
pulse
Interface
Single Rail mode 1
Dual Rail with Clock Recovery
Receive just slice the incoming data. Transmit is determined by the status of TCLKn.
Receive is power down. Transmit is determined by the status of TCLKn.
TABLE - 1b. SYSTEM INTERFACE CONFIGURATION (Host Mode)
MCLK
clocked
clocked
clocked
clocked
H
TDNn
H
pulse
pulse
pulse
pulse
CRSn in e-CRS
0
0
0
1
-
L
pulse
-
Host Mode
SINGn in e-SING
0
1
0
0
-
Interface
Single Rail mode 1
Single Rail mode 2
Dual Rail with Clock Recovery
Dual Rail with Data Recovery
Receive just slice the incoming data.
Transmit is determined by the status of TCLKn.
Receive is power down.
Transmit is determined by the status of TCLKn.
TABLE - 2. ACTIVE CLOCK EDGE AND ACTIVE LEVEL
Pin CLKE
RD/RDP and CV/RDN
Clock recovery
Slicer output
Low
RCLK
Active High
Active Low
High
RCLK
Active High
Active High
CLOCK EDGES
The active edge of RCLK and SCLK(serial interface clock) are also
selectable. If pin CLKE is Low, the active edge of RCLK is the rising
edge, as for SCLK, that is falling edge. On the contrary, if CLKE is High,
the active edge of RCLK is the falling edge and that of SCLK is rising
edge. Pins RDn/RDPn, CVn/RDNn and SDO are always active high, and
those output signals are valid on the active edge of RCLK and SCLK
respectively. See Table-2 for details. However, in dual rail mode without
clock recovery, pin CLKE is used to set the active level for RDPn/RDNn
raw slicing output: High for active high polarity and Low for active low. It
should be noted that data on pin SDI are always active high and is
sampled on the rising edge of SCLK. The data on pin TD/TDP or BPVI/
TDN are also always active high but is sampled on the falling edge of
TCLK, despite the level on CLKE.
SDO
SCLK
SCLK
Active High
Active High
RECEIVER
In receive path, the line signals couple into RRINGn and RTIPn via a
transformer and are converted into RZ digital pulses by a data slicer.
Adaptation for attenuation is achieved using an integral peak detector
that sets the slicing levels. Clock and data are recovered from the
received RZ digital pulses by a digital phase-locked loop that provides
excellent jitter accommodation. After passing through the selectable jitter
attenuator, the recovered data are decoded using B8ZS/HDB3 or AMI
line code rules and clocked out of pin RDn in single rail mode, or
presented on RDPn/RDNn in an undecoded dual rail NRZ format. Loss
of signal, alarm indication signal, line code violations and excessive zero
are detected. The presence of programmable inband loopback codes
are also detected. These various changes in status may be enabled to
generate interrupts.
Peak Detector and Slicer
The slicer determines the presence and polarity of the received
pulses. In data recovery mode, the raw positive slicer output appears on
14
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
B8ZS/HDB3/AMI Line Code Rule
Selectable B8ZS/HDB3 or AMI line coding/decoding is provided
when the device is configured in single rail mode. B8ZS rules for T1 or
HDB3 rules for E1 is enabled by setting bit CODE in register GCF (global control configuration) to ‘0’ or pulling pin CODE to Low. AMI rule is
enabled by setting bit CODE in GCF to ‘1’ or pulling pin CODE to High.
All the setting above are effected to eight channels.
Individual line code rule selection for each channel, if need, is available by setting bit SINGn in e-SING to ‘1’ (to activate bit CODEn in eCODE) and programming bit CODEn to select line code rules in the corresponding channel: ‘0’ for B8ZS/HDB3, while ‘1’ for AMI. In this case,
the value in bit CODE in GCF or pin CODE for global control is unaffected in the corresponding channel and only affect in other channels.
In dual rail mode, the decoder/encoder are bypassed. Bit CODE in
GCF, bit CODEn in e-CODE and pin CODE are ignored.
The configuration of the Line Code Rule is summarized in Table-3.
RDPn while the negative slicer output appears on RDNn. In clock and
data recovery mode, the slicer output is sent to Clock and Data Recovery circuit for abstracting retimed data and optional decoding. The slicer
circuit has a built-in peak detector from which the slicing threshold is derived. The slicing threshold is default to 50% (typical) of the peak value.
Signals with an attenuation of up to 12 dB (from 2.4V) can be recovered accurately by the receiver. To provide immunity from impulsive
noise, the peak detectors are held above a minimum level of 0.150 V
typically, despite the received signal level.
Clock and Data Recovery
The function of Clock and Data Recovery is accomplished by Digital
Phase Locked Loop (DPLL). The DPLL is clocked 16 times of the
received clock rate, i.e. 24.704 MHz in T1 mode or 32.768 MHz in E1
mode. The recovered data and clock from DPLL is then sent to the
selectable Jitter Attenuator or decoder circuit for further processing.
The clock recovery and data recovery mode can be selected on per
channel basis by setting the bit CRSn in e-CRS. When bit CRSn is
defaulted to ‘0’, the corresponding channel operates in data and clock
recovery mode. The recovered clock is output on pin RCLKn and retimed NRZ data are output on pin RDPn/RDNn in dual rail mode or on
RDn in single rail mode. When CRSn is ‘1’, dual rail with data recovery
mode is enabled in the corresponding channel and the clock recovery
function is bypassed. In this condition, the analog line signal are
converted to RZ digital bit streams on the RDPn/RDNn pins and
internally connected to an EXOR which is fed to the RCLKn output for
external clock recovery applications.
Moreover, Pulling MCLK to H level, all the receivers will enter the
dual rail with data recovery mode. In this case, e-CRS is ignored.
Loss of Signal (LOS) Detection
The Loss of Signal Detector monitors the amplitude and density of
the received signal on Receiver line before the transformer (measured
on port A, B in Figure 12). The loss condition is reported by pulling pin
LOSn to high. In the same time, LOS alarm registers track LOS
condition. When LOS detected or cleared, an interrupt will generate if
not masked. In host mode, the detection supports the ANSI T1.231 for
T1 mode and ITU-G.775 and ETSI 300233 for E1 mode. In hardware
mode, it only supports the ITU-G.775 and ANSI T1.231 specification.
Table-4 summarizes the conditions of LOS in clock recovery mode.
In data recovery mode, the LOS condition is cleared upon detecting
the signal level exceeds 540mV.
During LOS, the RDPn/RDNn output the sliced data when bit AISE in
TABLE - 3. CONFIGURATION OF THE LINE CODE RULE
Hardware Mode
CODE
L
H
Line Code Rule
All channels in
HDB3/B8ZS
All channels in AMI
Host Mode
CODE in GCF CODEn in e-CODE SINGn in e-SINGn
0
0/1
0
0
0
1
1
0/1
0
1
1
1
0
1
1
1
0
1
Line Code Rule
All channels in HDB3/B8ZS
All channels in AMI
CHn in AMI
CHn in HDB3/B8ZS
TABLE - 4. LOS CONDITION IN CLOCK RECOVERY MODE
ANSI T1.231 for T1
LOS
Detected
LOS
Continuous
Intervals
Amplitude
Density
Cleared
Amplitude
STANDARD
G.775 for E1
ETSI 300233 for E1
175
32
2048 (1 ms)
below typ. 310mV (Vpp)
12.5% (16 marks in a sliding
128-bit period) with no more
than 99 continuous zeros
exceed typ. 540mV (Vpp)
below typ. 310mV (Vpp)
12.5% (4 marks in a sliding
32-bit period) with no more
than 15 continuous zeros
exceed typ.540mV (Vpp)
below typ. 310mV (Vpp)
12.5% (4 marks in a sliding
32-bit period) with no more
than 15 continuous zeros
exceed typ. 540mV (Vpp)
15
Signal on
pin LOSn
H
L
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
are reported in both host mode and hardware mode with HDB3/B8ZS
line code rule is used. Moreover, in host mode, the expanded registers
e-CZER and e-CODV are used to determine whether the excessive zero
and code violation are reported respectively. When configured in AMI decoding mode, only bipolar violation can be reported.
The error detection is available only in single rail mode where the
pin RDNn/CVn is used as error report output (CVn pin).
The configuration and report status of error detection are summarized in Table-6.
register GCF is 0 or output all ones as AIS (alarm indication signal) when
bit AISE is set to 1; The RCLKn is replaced by MCLK only if the AISE is
set.
Alarm Indication Signal Detection (AIS)
Alarm Indication Signal is available only in host mode with clock
recovery, as Table-5 shows.
Error Detection
The device can detects excessive zero, bipolar violations and B8ZS/
HDB3 code violations, refer to figure-7, 8, 9. All the three kinds of errors
TABLE - 5. AIS CONDITION
ITU G.775 for E1
(register LAC defaulted to 0)
ETSI 300233 for E1
(register LAC is 1)
ANSI T1.231 for T1
AIS
detected
Less than 3 zeros contained in each of two
consecutive 512-bit stream are received
Less than 3 zeros contained in
a 512-bit stream are received
AIS
cleared
3 or more zeros contained in each of two
consecutive 512-bit stream are received
3 or more zeros contained in a
512-bit stream are received
Less than 9 zeros contained in a 8192-bit stream
(a ones density of 99.9% over a period of 5.3ms)
are received
9 or more zeros contained in a 8192-bit stream
are received
TABLE - 6. ERROR DETECTION
Hardware Mode
Line Code
Pin CVn Reports
AMI
Bipolar Violation
HDB3
/B8ZS
Bipolar Violation
+ Code Violation
+ Excessive Zero
Line Code
AMI
HDB3
/B8ZS
Host Mode
CODVn in e-CODV CZERn in e-CZER
Pin CVn Reports
Bipolar Violation
0
0
Bipolar Violation + Code Violation
0
1
Bipolar Violation + Code Violation + Excessive Zero
1
0
Bipolar Violation
1
1
Bipolar Violation + Excessive Zero
CLK
RTIP
RRING
RD
1
3
2
5
V
4
1
7
6
2
3
4
5
V
6
CV
Bipolar violation
Figure - 7. AMI Bipolar Violation
16
Bipolar Violation detected
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Code violation
CLK
RTIP
1
3
5
4 consecutive zeros
RRING
2
4
RD
1
V
2
V
3
6
4
5
6
CV
Excessive zero detected
Code violation detected
Figure - 8. HDB3 Code Violation & Excessive Zero
CLK
RTIP
RRING
RD
2
4
6
8
8 consecutive zeros
1
3
5
1
2
7
3
4
5
9
6
7
8
CV
Excessive zero detected
Figure - 9. B8ZS Excessive Zero
TRANSMITTER
In transmit path, data in NRZ (non return to zero) format are clocked
into the device on TDn and encoded by AMI or HDB3/B8ZS line code
rules when single rail mode is configured or pre-encoded data in NRZ
format are input on TDPn and TDNn when dual rail mode is configured.
The data are sampled into the device on falling edges of TCLKn. Jitter
attenuator, if enabled, is provided with a FIFO which the data to be
transmitted are passing through. A low jitter clock is generated by an
integral digital phase-locked loop and is used to read data from the
FIFO. The shape of the pulses are user programmable to ensure that
the T1/E1 pulse template is met after the signal is passed through
different cable lengths or types. Bipolar violation, for diagnosing, can be
inserted on pin BPVIn if AMI line code rule is enabled.
17
Waveform Shaper
T1 pulse template, specified in the DSX-1 Cross-Connect by ANSI
T1.102, is illustrated in Figure-10. The device has built-in transmit
waveform templates, corresponding to 5 levels of pre-equalization for
cable of a length from 0 to 655ft with each increment of 133ft.
E1 pulse template, specified in ITU-T G.703, is shown in Figure-11.
The device has built-in transmit waveform templates for cable of 75Ω or
120Ω.
Any one of the six built-in waveform can be chosen in both hardware
mode and host mode.
Setting the pins TS[2:0] as Table-7 in hardware mode can select the
required waveform template for all the transmitters.
In host mode, the waveform template can be configured on perchannel basis. Bit TSIA[2:0] in register TSIA is used to select the
channel and bit TS[2:0] in register TS is to select the required waveform
template. Refer to Register Description for details.
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
The built-in waveform shaper use an internal high frequency clock
which is 16XMCLK as clock reference. This function will be bypassed
when MCLK is unavailable.
Bipolar Violation Insertion
When configured in single rail mode 2 with AMI line code enabled,
pin TDNn/BPVIn is used as BPVI input. A low-to-high transition on this
pin inserts a bipolar violation on the next available mark in the transmit
data stream. Sampling occurs on the falling edge of TCLK. But in TAOS
with analog loopback mode, remote loopback mode and inband
loopback mode, the BPVI is disabled. In TAOS with digital loopback
mode, the BPVI is looped back to system side, so the data to be transmitted on TTINGn and TRINGn are all ones with no bipolar violation.
1.2
1
Normalized Amplitude
0.8
0.6
0.4
JITTER ATTENUATOR
The jitter attenuator is provided for narrow-band width jitter transfer
and can be selected to work either in transmit path or in receive path or
not used. The selection is accomplished by setting pin JAS in hardware
mode or configuring bits JACF1 and JACF0 in register GCF in host
mode which are both effected to all eight channels.
For applications which require line synchronization, the line clock is
need to be extracted for the internal synchronization, the jitter attenuator
is set in the receive path. Another use of the jitter attenuator is to provide clock smoothing in the transmit path for applications such as synchronous/asynchronous demultiplexing applications. In these applications, TCLK will have an instantaneous frequency that is higher than the
nominal T1/E1 data rate and in order to set the average long-term TCLK
frequency within the transmit line rate specifications, periods of TCLK
are suppressed (gapped).
The jitter attenuator integrates a FIFO which can accommodate a
gapped TCLK. In host mode, the FIFO length can be 32 X 2 or 64 X 2
bits by programming bit JADP in GCF. In hardware mode, it is fixed to
64 X 2 bits. The FIFO length determines the maximum permissible gap
width (see table-8), exceeding these values will cause FIFO overflow or
underflow. The data is 16 or 32 bits’ delay through the jitter attenuator in
the corresponding transmit or receive path. The constant delay feature
is crucial for the applications requiring “hitless” switching.
In host mode, bit JABW in GCF determines the jitter attenuator 3dB
corner frequency (fc) for both T1 and E1. In hardware mode, the fc is
fixed to 2.5Hz for T1 or 1.7Hz for E1. Generally, the lower the fc is, the
higher the attenuation. However, lower fc comes at the expense of
increased acquisition time. Therefore, the optimum fc is to optimize both
the attenuation and the acquisition time. In addition, the longer FIFO
length results in an increased throughput delay and also influences the
3dB corner frequency. Generally, it’s recommended to use the lower
0.2
0
-0.2
-0.4
-0.6
0
250
500
750
1000
1250
Time (ns)
Figure - 10. DSX-1 Waveform Template
1.20
1.00
Normalized Amplitude
0.80
0.60
0.40
0.20
0.00
-0.20
-300
-200
-100
0
Time (ns)
100
200
INDUSTRIAL TEMPERATURE RANGES
300
Figure - 11. CEPT Waveform Template
TABLE - 7. BUILT-IN WAVEFORM TEMPLATE SELECTION
TS2
TS1
TS0
Service
Clock Rate
0
0
0
E1
2.048 MHz
0
0
0
1
1
1
1
0
1
1
0
0
1
1
1
0
1
0
1
0
1
Cable Length
120 Ω / 75 Ω Cable
Maximum Cable Loss (dB) 1
-
Reserved
T1
1.544
MHz
0
133
266
399
533
NOTE:
1. Maximum cable loss at 772 KHz
18
-
133ft. ABAM
266ft. ABAM
399ft. ABAM
533ft. ABAM
655ft. ABAM
0.6
1.2
1.8
2.4
3.0
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
corner frequency and the shortest FIFO length that can still meet jitter
attenuation requirements.
LINE INTERFACE CIRCUITRY
The transmit and receive interface RTIP/RRING and TTIP/TRING
connections provide a matched interface to the cable. Figure-12 shows
the appropriate external components to connect with the cable for one
transmit/receive channel. Table-11 summarizes the component values
based on the specific application.
TABLE - 8. GAP WIDTH LIMITATION
FIFO Length
64 bit
32 bit
Max. Gap Width
56 UI
28 UI
TRANSMIT DRIVER POWER SUPPLY
All transmit driver power supplies must be 5.0V or 3.3V.
In E1 mode, despite of the power supply voltage, the 75Ω/120Ω
lines are driven through 9.5Ω series resistors and a 1:2 transformer.
In T1 mode, when 5.0V is selected, 100Ω lines are driven through
9.1Ω series resistors and a 1:2 transformer. When 3.3V, 100Ω lines are
driven through a 1:2 transformer. To optimize the power consumption of
the device, series resistors are removed in this case.
However, in harsh cable environment, series resistors are required to
improve the transmit return loss performance and protect the device
from surges coupling into the device.
TABLE - 9. OUTPUT JITTER SPECIFICATION
T1
AT&T Pub 62411
E1
ITU-T G.736
GR-253-CODE
ITU-T G.742
ITU-T G.783
ETSI CTR 12/13
TR-TSY-000009
INDUSTRIAL TEMPERATURE RANGES
TABLE - 10. TRANSFORMER SPECIFICATIONS
Electrical Specification @ 25 °C
Part No.
Turns Ratio (Pri: sec±2%) OCL @ 25°C (mH MIN)
LL (µH MAX)
STD Temp. EXT Temp.
Transmit Receive
Transmit Receive Transmit Receive
T1124
T1114
1:2CT
1CT:2
1.2
1.2
.6
.6
CW/W (pF MAX)
Transmit Receive
35
35
Package/
Schematic
TOU/3
TABLE - 11. EXTERNAL COMPONENTS VALUES
RT
RR
Cp
D1 - D4
E1
T1
120Ω Twisted Pair
100Ω Twisted Pair VDDT = 5.0V
100Ω Twisted Pair VDDT = 3.3V
9.5Ω ± 1%
9.1Ω ± 1%
0Ω
15Ω ± 1%
12.4Ω ± 1%
12.4Ω ± 1%
2200pf
1000pf
Nihon Inter Electronics - EP05Q03L, 11EQS03L, EC10QS04, EC10QS03L;
Motorola - MBR0540T1
75Ω Coax
9.5Ω ± 1%
9.31Ω ± 1%
One of Eight Identical Channels
1
A
2:1
• •
•
0.22µF
RX Line
•
•
B
1
2:1
• •
1kΩ
RTIPn
RR
RR
1kΩ
RT
VDDT
D4
D3
TX Line
Cp
RRINGn
·
TTIPn
IDT82V2048
Component
VDDDn
2
0.1µF
VDDT
D2
RT
VDDT
•
D1
GNDTn
·
68µF3
•
TRINGn
NOTE:
1. Pulse T1124 transformer is recommended to use in Standard (STD) operating temperature range (0° to 70°C), while Pulse T1114 transformer is recommended to use in Extended
(EXT) operating temperature range is -40° to +85°C. See Transformer Specifications Table for details.
2. Typical value. Adjust for actual board parasitics to obtain optimum return loss.
3. Common decoupling capacitor for all VDDT and GNDT pins.
Figure - 12. External Transmit/Receive Line Circuitry
19
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
POWER DRIVER FAILURE MONITOR
An internal power Driver Failure Monitor (DFM), parallelly connected
with TTIPn and TRINGn, can detect short circuit failure in the secondary
side of transformer. This feature is available only in host mode with no
transmit series resistors, i.e. in T1 mode with VDDT is 3.3V.
Bit SCPB in Register GCF decides whether the output driver shortcircuit protection is enabled. (Refer to Programming Information).
When it is enabled, the max driver’s output current is limited to 150mA.
INDUSTRIAL TEMPERATURE RANGES
RCLKn, RDn/RDPn and CVn/RDNn. The data to be transmitted are still
output on TTIPn and TRINGn while the data received on RTIPn and
RRINGn are ignored. The Loss Detector is still in use. Figure-13 shows
the process.
Analog Loopback
By programming the bits of ALB register or pulling pin LPn to High,
each channel of the device can be set in Analog Loopback. In this
configuration, the data to be transmitted output from the line driver are
internally looped back to the slicer and peak detector in the receive path
and output on RCLKn, RDn/RDPn and CVn/RDNn. The data to be
transmitted are still output on TTIPn and TRINGn while the data
received on RTIPn and RRINGn are ignored. The Loss Detector is still in
use. Figure-14 shows the process.
The TTIPn and RTIPn, TRINGn and RRINGn cannot be connected
directly to do the external analog loopback test. Line impedance loading
is required to connduct the external analog loopback test.
LINE PROTECTION
In transmit side, the Schottky diodes D1~D4 are required to protect
the line driver and improve the design robustness. In receive side, the
series resistors of 1kΩ are used to protect the receiver against current
surges coupled in the device. It does not affect the receiver sensitivity,
since the receiver impedance is as high as 120kΩ typically.
HITLESS PROTECTION SWITCHING (HPS)
The IDT82V2048 tranceivers include an output driver tristatability
feature for T1/E1 redundancy applications. This feature greatly reduces
the cost of implementing redundancy protection by eliminating external
relays. Details of HPS will be described in relative Application Note.
Remote Loopback
By programming the bits of RLB register or pulling pin LPn to Low,
each channel of the device can be set in Remote Loopback. In this
configuration, the data and clock recovered by the Clock and Data
Recovery circuits are looped to waveform shaper and output on TTIPn
and TRINGn. The jitter attenuator is also included in loopback when
enabled in the transmit or receive path. The received data and clock are
still output on RCLKn, RDn/RDPn and CVn/RDNn while the data to be
transmitted on TCLKn, TDn/TDPn and BPVIn/TDNn are ignored. The
Loss Detector is still in use. Figure-15 shows the process.
RESET
Writing register RS can cause software reset by initiating about 1µs
reset cycle. This operation set all the registers to their default value.
POWER UP
During power up, an internal reset signal sets all the registers to default values. This procedure takes at least 2 machine cycles.
Dual Loopback
Dual Loopback mode is set by setting both bit DLBn in register DLB
and bit RLBn in register RLB to ‘1’. In this configuration, after passing
the encoder, the data and clock to be transmitted are looped back to
decoder directly and output on RCLKn, RDn/RDPn and CVn/RDNn. The
recovered data from RTIPn and RRINGn are looped back to waveform
shaper through JA (if selected) and output on TTIPn and TRINGn. The
Loss Detector is still in use. Figure-16 shows the process.
POWER DOWN
Each transmitter channel will be power down by pulling pin TCLKn to
low for more than 64 MCLK cycles (if MCLK is available) or about 30us
(when MCLK is not availabe). Each transmitter channel will also be
power down by setting bit TPDNn in e-TPDN to 1.
All the receivers will power down when MCLK is Low. When MCLK is
clocked or High, setting bit RPDNn in e-RPDN to ‘1’ will configure the
corresponding receiver to power down.
Transmit All Ones
In hardware mode, the TAOS mode is set by pulling TCLKn High for
more than 16 MCLK cycles. In host mode, TAOS mode is set by programming register TAO. In addition, automatic TAO signals are inserted
by setting register ATAO when Loss of Signal occurs. Note that the
TAOS generator adopts MCLK as a timing reference. In order to assure
that the output frequency is within specification limits, MCLK must have
the applicable stability.
This TAOS mode and Digital Loopback or Analog Loopback can be
configured simultaneously.
Figure-17 shows their process.
INTERFACE WITH 5V LOGIC
The IDT82V2048 can interface directly with 5V TTL family devices.
The internal input pads are tolerant to 5V output from TTL and CMOS
family devices.
LOOPBACK MODE
The device provides five different diagnostic loopback configurations:
Digital Loopback, Analog Loopback, Remote Loopback, Dual Loopback
and Inband Loopback. In host mode, these functions are implemented
by programming the registers DLB, ALB, RLB or Inband Loopback register group. In hardware mode, only analog loopback and remote
loopback can be selected by pulling pin LPn to High and Low respectively.
Digital Loopback
By programming the bits of register DLB, each channel of the device
can be set in Local Digital Loopback. In this configuration, the data and
clock to be transmitted, after passing the encoder, is looped back to jitter
attenuator (if enabled) and decoder in the receive path, then output on
20
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
One of Eight Identical Channels
LOS
Detector
CLK&Data
Recovery
(DPLL)
RTIPn
Slicer
RRINGn
Line
Driver
TRINGn
Jitter
Attenuator
B8ZS/
HDB3/AMI
Decoder
RCLKn
RDn/RDPn
CVn/RDNn
Jitter
Attenuator
B8ZS/
HDB3/AMI
Encoder
TCLKn
TDn/TDPn
BPVIn/TDNn
Digital
Loopback
Peak
Detector
TTIPn
LOSn
Waveform
Shaper
Transmit
All Ones
Figure - 13. Digital Loopback
One of Eight Identical Channels
LOS
Detector
RTIPn
CLK&Data
Recovery
(DPLL)
Slicer
RRINGn
Analog
Loopback
LOSn
Jitter
Attenuator
B8ZS/
HDB3/AMI
Decoder
RCLKn
RDn/RDPn
CVn/RDNn
B8ZS/
HDB3/AMI
Encoder
TCLKn
TDn/TDPn
BPVIn/TDNn
Peak
Detector
TTIPn
Line
Driver
TRINGn
Jitter
Attenuator
Waveform
Shaper
Transmit
All Ones
Figure - 14. Analog Loopback
One of Eight Identical Channels
LOS
Detector
RTIPn
Slicer
RRINGn
LOSn
CLK&Data
Recovery
(DPLL)
TRINGn
Line
Driver
Waveform
Shaper
Jitter
Attenuator
RCLKn
RDn/RDPn
CVn/RDNn
IBLC
Detector
Remote/
Inband
Loopback
Peak
Detector
TTIPn
B8ZS/
HDB3/AMI
Decoder
Jitter
Attenuator
B8ZS/
HDB3/AMI
Encoder
TCLKn
TDn/TDPn
BPVIn/TDNn
IBLC
Generator
Transmit
All Ones
Figure - 15. Remote Loopback
21
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
One of Eight Identical Channels
LOS
Detector
RTIPn
Slicer
RRINGn
INDUSTRIAL TEMPERATURE RANGES
LOSn
CLK&Data
Recovery
(DPLL)
Jitter
Attenuator
B8ZS/
HDB3/AMI
Decoder
RCLKn
RDn/RDPn
CVn/RDNn
B8ZS/
HDB3/AMI
Encoder
TCLKn
TDn/TDPn
BPVIn/TDNn
Peak
Detector
TTIPn
Line
Driver
TRINGn
Waveform
Shaper
Jitter
Attenuator
Transmit
All Ones
Figure - 16. Dual Loopback
LOS
Detector
RTIPn
Slicer
RRINGn
CLK&Data
Recovery
(DPLL)
One of Eight Identical Channels
LOSn
B8ZS/
HDB3/AMI
Decoder
Jitter
Attenuator
RCLKn
RDn/RDPn
CVn/RDNn
Peak
Detector
TTIPn
TRINGn
Line
Driver
Waveform
Shaper
B8ZS/
HDB3/AMI
Encoder
Jitter
Attenuator
TCLKn
TDn/TDPn
BPVIn/TDNn
Transmit
All Ones
Figure - 17a. TAOS Data Path
LOS
Detector
RTIPn
Slicer
RRINGn
CLK&Data
Recovery
(DPLL)
One of Eight Identical Channels
LOSn
Jitter
Attenuator
B8ZS/
HDB3/AMI
Decoder
RCLKn
RDn/RDPn
CVn/RDNn
Jitter
Attenuator
B8ZS/
HDB3/AMI
Encoder
TCLKn
TDn/TDPn
BPVIn/TDNn
Peak
Detector
TTIPn
TRINGn
Line
Driver
Waveform
Shaper
Transmit
All Ones
Figure - 17b. TAOS with Digital Loopback
22
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
One of Eight Identical Channels
LOS
Detector
RTIPn
Slicer
RRINGn
LOSn
CLK&Data
Recovery
(DPLL)
Jitter
Attenuator
B8ZS/
HDB3/AMI
Decoder
RCLKn
RDn/RDPn
CVn/RDNn
Peak
Detector
TTIPn
TRINGn
Line
Driver
Waveform
Shaper
B8ZS/
HDB3/AMI
Encoder
TCLKn
TDn/TDPn
BPVIn/TDNn
Transmit
All Ones
Figure - 17c. TAOS with Analog Loopback
Inband Loopback
Inband Loopback is a function that facilitates the system remote diagnosis. When this function is enabled, the chip will detect or generate
the Inband Loopback Code. There are two kinds of Inband Loopback
Code:Active Code and Deactive Code. If the Active Code is received
from the far end in a continuous 5.1 second, the chip can go into Remote Loopback Mode (Figure-15) automatically. If the Deactive Code is
received from the far end in a continuous 5.1 second, the chip can quit
from the Remote Loopback mode automatically. The chip can also send
the Active Code and Deactive Code to the far end. Two function blocks
realize the Inband Loopback : IBLC Detector (Inband Loopback Code
Detector) and IBLC Generator ( Inband Loopback Code Generator).
The detection of Inband Loopback Code is enabled by LBDE (bit 5,
e-LBCF register). If ALBE (bit 4, e-LBCF register) is set to 1, the chip
will go into or quit from the Remote Loopback mode automatically based
on the receipt of Inband Loopback Code. The length of the Active Code
is defined in LBAL[1:0] (bit 3-2, e-LBCF register); and the length of the
Deactive Code is defined in the LBDL[1:0] (bit 1-0, e-LBCF register).
The pattern of the Active Code is defined in the e-LBAC register, and
the pattern of the Deactive Code is defined in the e-LBDC register. The
above settings are globally effective for all the eight channels. The presence of Inband Loopback Code in each channel is reflected timely in the
e-LBS register. Any transition of each bit in the e-LBS register will be
reflected in the e-LBI register, and if enabled in the e-LBM register,
will generate an interrupt. The required sequence of programming
the Inband Loopback Code detection is : First, set the e-LBAC and eLBDC registers, followed by the e-LBM register. Finally, to activate
Inband Loopback detection, set the e-LBCF register.
The Inband Loopback Code Generator use the same registers as
the Inband Loopback Detector to define the length and pattern of Active Code and Deactive Code. The length and pattern of the generated Active Code and Deactive Code can be different from the detected Active Code and Deactive Code. The e-LBGS register determines sending Active Code or Deactive Code, and the e-LBGE acts
as a switch button to start or stop the sending of Inband Loopback
Code to the selected channels. Before sending Inband Loopback
Code, users should be sure that the e-LBCF register, the e-LBAC
register, the e-LBDC register and the e-LBSG register are configured
properly. The required sequence for configuring the Inband Loopback
Generator is: First, set the e-LBAC and e-LBDC registers, followed by
the e-LBCF register. Then, to select the Inband Loopback generator
set e-LBGS and then e-LBGE.
The Inband Loopback Detection and the Inband Loopback Genera-
tion can not be used simultaneously.
Example: 5-bit Loop-up/Loop-Down Detection (w/o interrupts):
(see note in register description for e-LBAC)
Loop-up code: 11000
Loop-down code : 11100
Set (in this order)
e-LBAC (0x09) = 0xC6 (11000110)
e-LBDC (0x0A) = 0xE7 (11100111)
e-LBCF (0x08) = 0x30
Example: 5-bit Loop-up/Loop-down Activation on Channel 1 (w/o
interrupts):
Loop-up code: 11000
Loop-down code : 11100
Set (in this order)
e-LBAC (0x09) = 0xC6 (11000110)
e-LBDC (0x0A) = 0xE7 (11100111)
e-LBCF (0x08) = 0x00
e-LBGS (0x0E) = 0x00
e-LBGE (0x0F) = 0x02
HOST INTERFACES
The host interface provides access to read and write the registers
in the device. The interface consists of serial host interface and
parallel host interface. By pulling pin MODE2 to VDDIO/2 or to High,
the device can be set to work in serial mode and in parallel mode
respectively.
Parallel Host Interface
The interface is compatible with Motorola or Intel host. Pins
MODE1 and MODE0 are used to select the operating mode of the
parallel host interface. When pin MODE1 is pulled to Low, the host
uses separate address bus and data bus. When High, multiplexed
address/data bus is used. When pin MODE0 is pulled to Low, the parallel host interface is configured for Motorola compatible hosts. When
High, for Intel compatible hosts. This is well described in the Pin Description. The host interface pins in each operation mode is tabulated in Table-12.
23
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TABLE - 12. PARALLEL HOST INTERFACE PINS
MODE[2:0]
100
101
110
111
Host interface
Non-multiplexed Motorola interface
Non-multiplexed Intel interface
Multiplexed Motorola interface
Multiplexed Intel interface
Generic control, data, and output pin name
CS, ACK, DS, R/W, AS, A[4:0], D[7:0], INT
CS, RDY, WR, RD, ALE, A[4:0], D[7:0], INT
CS, ACK, DS, R/W, AS, AD[7:0], INT
CS, RDY, WR, RD, ALE, AD[7:0], INT
CS
SCLK
SDI
2
2
1
R/W A1 A2 A3 A4 A5 A6 A7 D0 D1 D2 D3 D4 D5 D6 D7
Address/Command Byte
Input Data Byte
SDO
D0 D1 D2 D3 D4 D5 D6 D7
High Impedance
Driven while R/W=1
NOTE:
1. While R/W=1, read from IDT82V2048; While R/W=0, write to IDT82V2048.
2. Ignored.
Figure - 18. Serial Host Mode Timing
Serial Host Interface
By pulling pin MODE2 to VDDIO/2, the device operates in the serial
host Mode. In this mode, the registers are accessible through a 16-bit
word which contains an 8-bit command/address byte (bit R/W and 5address-bit A1~A5, A6 and A7 are ignored) and a subsequent 8-bit
data byte (D0~D7). When bit R/W is 1, data is read out at pin SDO.
When bit R/W is 0, data is written into pin SDI to the register which is
indicated by address bits A5~A1.
Interrupt Allowed
No
INTERRUPT HANDLING
Interrupt Sources
There are four kinds of interrupt sources:
1. Status change in the LOS (Loss of Signal) Status Register(04H).
The analog/digital loss of signal detector continuously monitors the received signal to update the specific bit in LOS which indicates presence
or absence of a LOS condition.
2. Status change in the DF (Driver Fault) Status Register(05H). The
automatic power driver circuit continuously monitors the output drivers
signal to update the specific bit in DFM which indicates presence or absence of a secondary driver short circuit condition.
3. Status change in the AIS (Alarm Indication Signal) Status
Register(13H). The AIS detector monitors the received signal to update the specific bit in AIS which indicates presence or absence of a
AIS condition.
4. Status change in the e-LBS (Inband Loopback Code Receive)
Status Register, (expanded 0BH). The IBLC detector monitors the
inband loopback activation or deactivation code in received signal to
update the specific bit in e-LBS which indicates presence or absence
of an inband loopback condition.
Interrupt Condition
Exist?
Yes
Read Interrupt Status Register
Read Corresponding Status
Register
Service the Interrupt
Figure - 19. Interrupt Service Routine
24
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
G.772 MONITORING
The eight channels of IDT82V2048 can all be configured to work as
regular transceivers. In applications using only seven channels
(channels 1 to 7), channel 0 is configured to non-intrusively monitor
any of the other channels’ inputs or outputs on the line side. The
monitoring is non-intrusive per ITU-T G.772. Figure-20 shows the
Monitoring Principle. The receiver or transmitter path to be monitored
is configured by pin MC[0:3] in hardware mode or by PMON in host
mode (refer to Programming Information for details).
The signal which is monitored goes through the clock and data
recovery circuit of channel 0. The monitored clock can output on RCLK0
which can be used as a timing interfaces derived from E1 signal. The
monitored data can be observed digitally at the output pin RCLK0,
RD0/RDP0 and RDN0. LOS detector is still in use in channel 0 for the
monitored signal.
In monitoring mode, channel 0 can be configured to the Remote
Loopback. The signal which is being monitored will output on TTIP0 and
TRING0. The output signal can then be connected to a standard test
equipment with an E1 electrical interface for non-intrusive monitoring.
Interrupt Enable
The IDT82V2048 provides a latched interrupt output (INT) and the
four kinds of interrupts are all reported by this pin. When the Interrupt
Mask register (LOSM , DFM, AISM and e-LBM) is set to ‘1’, the Interrupt Status register (LOSI, DFI, AISI and e-LBI) is enabled respectively. Whenever there is a transition (‘0’ to ‘1’ or ‘1’ to ‘0’) in the corresponding Status register, the Interrupt Status register will change into
‘1’, which means an interrupt occurs, and there will be a transition
from high to low on INT. An external pull-up resistor of approximately
10kΩ is required to support the wire-OR operation of INT. When any
of the four Interrupt Mask registers is set to ‘0’ (the power-on default
value is ‘0’), the corresponding Interrupt Status register is disabled
and the transition on status register is ignored.
Interrupt Clearing
When an interrupt occurs, the Interrupt Status registers (LOSI, DFI,
AISI and e-LBI) are read to identify the interrupt source. And these
registers will be cleared to ‘0’ after the corresponding Status register
(LOS, DF, AIS and e-LBS) being read. The Status registers will be
cleared once the corresponding conditions are met.
Pin INT is pulled High when there are no pending interrupt left.
The interrupt handling in the interrupt service routine is showed Figure-19.
25
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Channel N ( 7 > N > 1 )
LOS
Detector
RTIPn
Slicer
RRINGn
LOSn
CLK&Data
Recovery
(DPLL)
Jitter
Attenuator
B8ZS/
HDB3/AMI
Decoder
RCLKn
RDn/RDPn
CVn/RDNn
Waveform
Shaper
Jitter
Attenuator
B8ZS/
HDB3/AMI
Encoder
TCLKn
TDn/TDPn
BPVIn/TDNn
Peak
Detector
TTIPn
Line
Driver
TRINGn
Transmit
All Ones
Channel 0
G.772
Monitor
LOS
Detector
RTIP0
Slicer
RRING0
CLK&Data
Recovery
(DPLL)
LOS0
Jitter
Attenuator
TRING0
Line
Driver
RCLK0
RD0/RDP0
CV0/RDN0
Remote
Loopback
Peak
Detector
TTIP0
B8ZS/
HDB3/AMI
Decoder
Waveform
Shaper
Jitter
Attenuator
Transmit
All Ones
Figure - 20. Monitoring Principle
26
B8ZS/
HDB3/AMI
Encoder
TCLK0
TD0/TDP0
BPVI0/TDN0
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
PROGRAMMING INFORMATION
INDUSTRIAL TEMPERATURE RANGES
to address the register.
TheAddressPoint
erControlRegisterA(DDP), addressed as 11111 or
1F Hex, switches between primary registers bank and expanded registers
bank.
By setting the content of ADDP to AAH, the 5 address bits point to the
expanded register bank, that is, 16 expanded registers are then available
to access. By clearing ADDP, the primary registers are accessible again.
REGISTER LIST AND MAP
There are 23 primary registers (including an Address Pointer Control
Register), including 16 expanded registers in the device.
Whatever the control interface is, 5 address bits are used to set the
registers. In non-multiplexed parallel interface mode, the five dedicated
address bits are A[4:0]. In multiplexed parallel interface mode, AD[4:0]
carries the address information. In serial interface mode, A[5:1] are used
TABLE - 13. PRIMARY REGISTER LIST
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
Address
serial
parallel
interface
interface
A7-A1
A7-A0
XX00000 XXX00000
XX00001 XXX00001
XX00010 XXX00010
XX00011 XXX00011
XX00100 XXX00100
XX00101 XXX00101
XX00110 XXX00110
XX00111 XXX00111
XX01000 XXX01000
XX01001 XXX01001
XX01010 XXX01010
XX01011 XXX01011
XX01100 XXX01100
XX01101 XXX01101
XX01110 XXX01110
XX01111 XXX01111
XX10000 XXX10000
XX10001 XXX10001
XX10010 XXX10010
XX10011 XXX10011
XX10100 XXX10100
XX10101 XXX10101
XX10110 XXX10110
XX10111 XXX10111
XX11000 XXX11000
XX11001 XXX11001
XX11010 XXX11010
XX11011 XXX11011
XX11100 XXX11100
XX11101 XXX11101
XX11110 XXX11110
1F
XX11111
Hex
Register
ID
ALB
RLB
TAO
LOS
DF
LOSM
DFM
LOSI
DFI
RS
PMON
DLB
LAC
ATAO
GCF
TSIA
TS
OE
AIS
AISM
AISI
XXX11111 ADDP
R/W
R
R/W
R/W
R/W
R
R
R/W
R/W
R
R
W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R/W
R
Explanation
Device ID Register
Analog Loopback Configuration Register
Remote Loopback Configuration Register
Transmit All One Code Configuration Register
Loss of Signal Status Register
Driver Fault Status Register
LOS Interrupt Mask Register
Driver Fault Interrupt Mask Register
LOS Interrupt Status Register
Driver Fault Interrupt Status Register
Software Reset Register
Performance Monitor Configuration Register
Digital Loopback Configuration Register
LOS/AIS Criteria Configuration Register
Automatic TAO Configuration Register
Global Configuration Register
Indirect Address Register for Transmit Template Select
Transmit Template Select Register
Output Enable Configuration Register
AIS Status Register
AIS Interrupt Mask Register
AIS Interrupt Status Register
Reserved
R/W
Address pointer control Register for switching between
primary register bank and expanded register bank
27
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TABLE - 14. EXPANDED (INDIRECT ADDRESS MODE) REGISTER LIST
Address
serial
Hex interface
A7-A1
00 XX00000
01 XX00001
02 XX00010
03 XX00011
04 XX00100
05 XX00101
06 XX00110
07 XX00111
08 XX01000
09 XX01001
0A XX01010
0B XX01011
0C XX01100
0D XX01101
parallel
interface
A7-A0
XXX00000
XXX00001
XXX00010
XXX00011
XXX00100
XXX00101
XXX00110
XXX00111
XXX01000
XXX01001
XXX01010
XXX01011
XXX01100
XXX01101
0E
XX01110
XXX01110 e-LBGS
0F
XX01111
XXX01111 e-LBGE
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
XX10000
XX10001
XX10010
XX10011
XX10100
XX10101
XX10110
XX10111
XX11000
XX11001
XX11010
XX11011
XX11100
XX11101
XX11110
XXX10000
XXX10001
XXX10010
XXX10011
XXX10100
XXX10101
XXX10110
XXX10111
XXX11000
XXX11001
XXX11010
XXX11011
XXX11100
XXX11101
XXX11110
1F
XX11111
XXX11111 ADDP
Register
e-SING
e-CODE
e-CRS
e-RPDN
e-TPDN
e-CZER
e-CODV
e-EQUA
e-LBCF
e-LBAC
e-LBDC
e-LBS
e-LBM
e-LBI
R/W
Explanation
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R/W
R
Single Rail Mode Setting Register
Encoder/Decoder Selection Register
Clock Recovery Enable/Disable Register
Receiver n Powerdown Enable/Disable Register
Transmitter n Powerdown Enable/Disable Register
Consecutive Zero Detect Enable/Disable Register
Code Violation Detect Enable/Disable Register
Enable Equalizer Enable/Disable Register
Inband Loopback Configuration Register
Inband Loopback Activation Code Register
Inband Loopback Deactivation Code Register
Inband Loopback Code Receive Status Register
Inband Loopback Interrupt Mask Register
Inband Loopback Interrupt Status Register
Inband Loopback Activation/Deactivation Code Generator
R/W
Selection Register
Inband Loopback Activation/Deactivation Code Generator
R/W
Enable Register
Test
R/W
Address pointer control register for switching between primary
register bank and expanded register bank
28
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TABLE - 15. PRIMARY REGISTER MAP
Register
ID
ALB
RLB
TAO
LOS
DF
LOSM
DFM
LOSI
DFI
RS
PMON
DLB
LAC
ATAO
GCF
Address
R/W
b7
Default
00 Hex
ID 7
R/W
R
Default
0
01 Hex
ALB 7
R/W
R/W
0
Default
02 Hex
RLB 7
R/W
R/W
Default
0
03 Hex
TAO 7
R/W
R/W
Default
0
04 Hex
LOS 7
R/W
R
0
Default
05 Hex
DF 7
R/W
R
0
Default
06 Hex
LOSM 7
R/W
R/W
Default
0
07 Hex
DFM 7
R/W
R/W
0
Default
08 Hex
LOSI 7
R
R/W
0
Default
09 Hex
DFI 7
R
R/W
0
Default
0A Hex
RS 7
W
W
Default
1
0B Hex
R/W
R/W
Default
0
0C Hex
DLB 7
R/W
R/W
Default
0
0D Hex
LAC 7
R/W
R/W
Default
0
0E Hex
ATAO 7
R/W
R/W
Default
0
0F Hex
R/W
R/W
Default
0
b6
b5
b4
b3
b2
b1
b0
ID 6
R
0
ALB 6
R/W
0
RLB 6
R/W
0
TAO 6
R/W
0
LOS 6
R
0
DF 6
R
0
LOSM 6
R/W
0
DFM 6
R/W
0
LOSI 6
R
0
DFI 6
R
0
RS 6
W
1
R/W
0
DLB 6
R/W
0
LAC 6
R/W
0
ATAO 6
R/W
0
AISE
R/W
0
ID 5
R
0
ALB 5
R/W
0
RLB 5
R/W
0
TAO 5
R/W
0
LOS 5
R
0
DF 5
R
0
LOSM 5
R/W
0
DFM 5
R/W
0
LOSI 5
R
0
DFI 5
R
0
RS 5
W
1
R/W
0
DLB 5
R/W
0
LAC 5
R/W
0
ATAO 5
R/W
0
SCPB
R/W
0
ID 4
R
1
ALB 4
R/W
0
RLB 4
R/W
0
TAO 4
R/W
0
LOS 4
R
0
DF 4
R
0
LOSM 4
R/W
0
DFM 4
R/W
0
LOSI 4
R
0
DFI 4
R
0
RS 4
W
1
R/W
0
DLB 4
R/W
0
LAC 4
R/W
0
ATAO 4
R/W
0
CODE
R/W
0
ID 3
R
0
ALB 3
R/W
0
RLB 3
R/W
0
TAO 3
R/W
0
LOS 3
R
0
DF 3
R
0
LOSM 3
R/W
0
DFM 3
R/W
0
LOSI 3
R
0
DFI 3
R
0
RS 3
W
1
MC 3
R/W
0
DLB 3
R/W
0
LAC 3
R/W
0
ATAO 3
R/W
0
JADP
R/W
0
ID 2
R
0
ALB 2
R/W
0
RLB 2
R/W
0
TAO 2
R/W
0
LOS 2
R
0
DF 2
R
0
LOSM 2
R/W
0
DFM 2
R/W
0
LOSI 2
R
0
DFI 2
R
0
RS 2
W
1
MC 2
R/W
0
DLB 2
R/W
0
LAC 2
R/W
0
ATAO 2
R/W
0
JABW
R/W
0
ID 1
R
0
ALB 1
R/W
0
RLB 1
R/W
0
TAO 1
R/W
0
LOS 1
R
0
DF 1
R
0
LOSM 1
R/W
0
DFM 1
R/W
0
LOSI 1
R
0
DFI 1
R
0
RS 1
W
1
MC 1
R/W
0
DLB 1
R/W
0
LAC 1
R/W
0
ATAO 1
R/W
0
JACF 1
R/W
0
ID 0
R
0
ALB 0
R/W
0
RLB 0
R/W
0
TAO 0
R/W
0
LOS 0
R
0
DF 0
R
0
LOSM 0
R/W
0
DFM 0
R/W
0
LOSI 0
R
0
DFI 0
R
0
RS 0
W
1
MC 0
R/W
0
DLB 0
R/W
0
LAC 0
R/W
0
ATAO 0
R/W
0
JACF 0
R/W
0
29
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TABLE - 15. PRIMARY REGISTER MAP (CONTINUED)
Register
TSIA
TS
OE
AIS
AISM
AISI
ADDP
Address
R/W
b7
Default
10 Hex
R/W
R/W
Default
0
11 Hex
R/W
R/W
Default
0
12 Hex
OE 7
R/W
R/W
0
Default
13 Hex
AIS 7
R/W
R
Default
0
14 Hex
AISM 7
R/W
R/W
Default
0
15 Hex
AISI 7
R/W
R
0
Default
1F Hex
ADDP 7
R/W
R/W
0
Default
b6
b5
b4
b3
b2
b1
b0
R/W
0
R/W
0
OE 6
R/W
0
AIS 6
R
0
AISM 6
R/W
0
AISI 6
R
0
ADDP 6
R/W
0
R/W
0
R/W
0
OE 5
R/W
0
AIS 5
R
0
AISM 5
R/W
0
AISI 5
R
0
ADDP 5
R/W
0
R/W
0
R/W
0
OE 4
R/W
0
AIS 4
R
0
AISM 4
R/W
0
AISI 4
R
0
ADDP 4
R/W
0
R/W
0
R/W
0
OE 3
R/W
0
AIS 3
R
0
AISM 3
R/W
0
AISI 3
R
0
ADDP 3
R/W
0
TSIA 2
R/W
0
TS 2
R/W
0
OE 2
R/W
0
AIS 2
R
0
AISM 2
R/W
0
AISI 2
R
0
ADDP 2
R/W
0
TSIA 1
R/W
0
TS 1
R/W
0
OE 1
R/W
0
AIS 1
R
0
AISM 1
R/W
0
AISI 1
R
0
ADDP 1
R/W
0
TSIA 0
R/W
0
TS 0
R/W
0
OE 0
R/W
0
AIS 0
R
0
AISM 0
R/W
0
AISI 0
R
0
ADDP 0
R/W
0
30
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TABLE - 16. EXPANDED (INDIRECT ADDRESS MODE) REGISTER MAP
Register
e-SING
e-CODE
e-CRS
e-RPDN
e-TPDN
e-CZER
e-CODV
e-EQUA
e-LBCF
e-LBAC
e-LBDC
e-LBS
e-LBM
e-LBI
e-LBGS
e-LBGE
ADDP
Address
R/W
Default
00 Hex
R/W
Default
01 Hex
R/W
Default
02 Hex
R/W
Default
03 Hex
R/W
Default
04 Hex
R/W
Default
05 Hex
R/W
Default
06 Hex
R/W
Default
07 Hex
R/W
Default
08 Hex
R/W
Default
09 Hex
R/W
Default
0A Hex
R/W
Default
0B Hex
R
Default
0C Hex
R/W
Default
0DHex
R/W
Default
0E Hex
R/W
Default
0F Hex
R/W
Default
1F Hex
R/W
Default
b7
b6
b5
b4
b3
b2
b1
b0
SING 7
R/W
0
CODE 7
R/W
0
CRS 7
R/W
0
RPDN 7
R/W
0
TPDN 7
R/W
0
CZER 7
R/W
0
CODV 7
R/W
0
EQUA 7
R/W
0
R/W
0
LBAC 7
R/W
0
LBDC 7
R/W
0
LBS 7
R
0
LBM 7
R/W
0
LBI 7
R
0
LBGS 7
R/W
0
LBGE 7
R/W
0
ADDP 7
R/W
0
SING 6
R/W
0
CODE 6
R/W
0
CRS 6
R/W
0
RPDN 6
R/W
0
TPDN 6
R/W
0
CZER 6
R/W
0
CODV 6
R/W
0
EQUA 6
R/W
0
R/W
0
LBAC 6
R/W
0
LBDC 6
R/W
0
LBS 6
R
0
LBM 6
R/W
0
LBI 6
R
0
LBGS 6
R/W
0
LBGE 6
R/W
0
ADDP 6
R/W
0
SING 5
R/W
0
CODE 5
R/W
0
CRS 5
R/W
0
RPDN 5
R/W
0
TPDN 5
R/W
0
CZER 5
R/W
0
CODV 5
R/W
0
EQUA 5
R/W
0
LBDE
R/W
0
LBAC 5
R/W
0
LBDC 5
R/W
0
LBS 5
R
0
LBM 5
R/W
0
LBI 5
R
0
LBGS 5
R/W
0
LBGE 5
R/W
0
ADDP 5
R/W
0
SING 4
R/W
0
CODE 4
R/W
0
CRS 4
R/W
0
RPDN 4
R/W
0
TPDN 4
R/W
0
CZER 4
R/W
0
CODV 4
R/W
0
EQUA 4
R/W
0
ALBE
R/W
0
LBAC 4
R/W
0
LBDC 4
R/W
0
LBS 4
R
0
LBM 4
R/W
0
LBI 4
R
0
LBGS 4
R/W
0
LBGE 4
R/W
0
ADDP 4
R/W
0
SING 3
R/W
0
CODE 3
R/W
0
CRS 3
R/W
0
RPDN 3
R/W
0
TPDN 3
R/W
0
CZER 3
R/W
0
CODV 3
R/W
0
EQUA 3
R/W
0
LBAL 1
R/W
0
LBAC 3
R/W
0
LBDC 3
R/W
0
LBS 3
R
0
LBM 3
R/W
0
LBI 3
R
0
LBGS 3
R/W
0
LBGE 3
R/W
0
ADDP 3
R/W
0
SING 2
R/W
0
CODE 2
R/W
0
CRS 2
R/W
0
RPDN 2
R/W
0
TPDN 2
R/W
0
CZER 2
R/W
0
CODV 2
R/W
0
EQUA 2
R/W
0
LBAL 0
R/W
0
LBAC 2
R/W
0
LBDC 2
R/W
0
LBS 2
R
0
LBM 2
R/W
0
LBI 2
R
0
LBGS 2
R/W
0
LBGE 2
R/W
0
ADDP 2
R/W
0
SING 1
R/W
0
CODE 1
R/W
0
CRS 1
R/W
0
RPDN 1
R/W
0
TPDN 1
R/W
0
CZER 1
R/W
0
CODV 1
R/W
0
EQUA 1
R/W
0
LBDL 1
R/W
0
LBAC 1
R/W
0
LBDC 1
R/W
0
LBS 1
R
0
LBM 1
R/W
0
LBI 1
R
0
LBGS 1
R/W
0
LBGE 1
R/W
0
ADDP 1
R/W
0
SING 0
R/W
0
CODE 0
R/W
0
CRS 0
R/W
0
RPDN 0
R/W
0
TPDN 0
R/W
0
CZER 0
R/W
0
CODV 0
R/W
0
EQUA 0
R/W
0
LBDL 0
R/W
0
LBAC 0
R/W
0
LBDC 0
R/W
0
LBS 0
R
0
LBM 0
R/W
0
LBI 0
R
0
LBGS 0
R/W
0
LBGE 0
R/W
0
ADDP 0
R/W
0
31
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
REGISTER DESCRIPTION
Primary Register Description
ID: Device ID Register (R, Address = 00 Hex)
Symbol
Position
Default
ID[7:0]
ID.7-0
10 H
Description
An 8-bit word is pre-set into the device as the identification and revision number. This number is
different with the functional changes and is mask programmed.
ALB: Analog Loopback Configuration Register (R/W, Address = 01 Hex)
Symbol
ALB[7:0]
Position
ALB.7-0
Default
Description
0 = Normal operation. (Default)
1 = Analog Loopback enabled.
00 H
RLB: Remote Loopback Configuration Register (R/W, Address = 02 Hex)
Symbol
RLB[7:0]
Position
RLB.7-0
Default
Description
0 = Normal operation. (Default)
1 = Remote Loopback enabled.
00 H
TAO: Transmit All One Code Configuration Register (R/W, Address = 03 Hex)
Symbol
TAO[7:0]
Position
Default
TAO.7-0
Description
0 = Normal operation. (Default)
1 = Transmit all one code.
00 H
LOS: Loss of Signal Status Register (R, Address = 04 Hex)
Symbol
LOS[7:0]
Position
Default
LOS.7-0
Description
0 = Normal operation. (Default)
1 = Loss of signal detected.
00 H
DF: Driver Fault Status Register (R, Address = 05 Hex)
Symbol
Position
Default
DF[7:0]
DF.7-0
00 H
Description
0 = Normal operation. (Default)
1 = Driver fault detected.
Note that DF is available only in T1 mode with 3.3V (without transmit series resistors).
LOSM : Loss of Signal Interrupt Mask Register (R/W, Address = 06 Hex)
Symbol
Position
Default
LOSM[7:0]
LOSM.7-0
00 H
Description
0 = LOS interrupt is not allowed. (Default)
1 = LOS interrupt is allowed.
DFM: Driver Fault Interrupt Mask Register (R/W, Address = 07 Hex)
Symbol
Position
Default
DFM[7:0]
DFM.7-0
00 H
Description
0 = Driver fault interrupt is not allowed. (Default)
1 = Driver fault interrupt is allowed.
32
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
LOSI: Loss of Signal Interrupt Status Register (R, Address = 08 Hex)
Symbol
Position
Default
LOSI[7:0]
LOSI.7-0
00 H
Description
0 = (Default). Or after a LOS read operation.
1 = Any transition on LOSn (Corresponding LOSMn is set to 1).
DFI: Driver Fault Interrupt Status Register (R, Address = 09 Hex)
Symbol
Position
Default
DFI[7:0]
DFI.7-0
00 H
Description
0 = (Default). Or after a DF read operation.
1 = Any transition on DFn (Corresponding DFMn is set to 1).
RS: Software Reset Register (W, Address = 0A Hex)
Symbol
Position
Default
RS[7:0]
RS.7-0
FF H
Description
Writing to this register will not change the content in this register but initiate a 1µs reset cycle,
which means all the registers in the device are set to their default values.
PMON: Performance Monitor Configuration Register (R/W, Address = 0B Hex)
Symbol
Position
Default
-
PMON.7-4
0000
MC[3:0]
PMON.3-0
0000
Description
0 = Normal operation. (Default)
1 = Reserved.
MC[3:0]
Monitoring Configuration
0000
Normal operation without monitoring.
0001
Monitoring receiver 1.
0010
Monitoring receiver 2.
0011
Monitoring receiver 3.
0100
Monitoring receiver 4.
0101
Monitoring receiver 5.
0110
Monitoring receiver 6.
0111
Monitoring receiver 7.
1000
Normal operation without monitoring.
1001
Monitoring transmitter 1.
1010
Monitoring transmitter 2.
1011
Monitoring transmitter 3.
1100
Monitoring transmitter 4.
1101
Monitoring transmitter 5.
1110
Monitoring transmitter 6.
1111
Monitoring transmitter 7.
DLB: Digital Loopback Configuration Register (R/W, Address = 0C Hex)
Symbol
DLB[7:0]
Position
DLB.7-0
Default
00 H
Description
0 = Normal operation. (Default)
1 = Digital Loopback enabled.
LAC: LOS/AIS Criteria Configuration Register (R/W, Address = 0D Hex)
Symbol
Position
Default
LAC[7:0]
LAC.7-0
00 H
Description
For E1 mode, the criterion is selected as below:
0 = G.775 mode. (Default)
1 = ETSI 300233 mode.
For T1 mode, the criterion meets T1.231.
33
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
ATAO: Automatic TAO Configuration Register (R/W, Address = 0E Hex)
Symbol
Position
Default
ATAO[7:0]
ATAO.7-0
00 H
Description
0 = No automatic TAO. (Default)
1 = Automatic transmit all ones to the line side on LOS.
GCF: Global Configuration Register (R/W, Address = 0F Hex)
Symbol
Position
Default
-
GCF.7
0
AISE
GCF.6
0
SCPB
GCF.5
0
CODE
GCF.4
0
JADP
GCF.3
0
JABW
GCF.2
0
JACF[1:0]
GCF.1-0
00
Description
0 = Normal operation. (Default)
1 = Reserved.
AIS Enable During LOS.
0 = AIS insertion to the system side disabled on LOS. (Default)
1 = AIS insertion to the system side enabled on LOS.
Short Circuit Protection Enable.
0 = Short circuit protection is enabled. (Default)
1 = Short circuit protection is disabled.
Line Code Enable.
0 = B8ZS/HDB3 encoder/decoder enabled. (Default)
1 = AMI encoder/decoder enabled.
Jitter Attenuator Depth Select.
JADP
FIFO
0
32-bit (Default)
1
64-bit
Jitter Transfer Function Bandwidth Select.
JABW
T1
E1
0
2.5Hz (Default)
1.7Hz (Default)
1
5Hz
6.5Hz
Jitter Attenuator Configuration.
JACF[1:0]
Jitter Attenuator (JA) Configuration
00
JA not used. (Default)
01
JA in transmit path.
10
JA not used.
11
JA in receive path.
TSIA: Indirect Address Register for Transmit Template Select Registers (R/W, Address = 10 Hex)
Symbol
-
TSIA[2:0]
Position
TSIA.7-3
TSIA.2-0
Default
00000
000
Description
0 = Normal operation. (Default)
1 = Reserved.
TSIA[2:0]
Channel
000
0
001
1
010
2
011
3
34
TSIA[2:0]
100
101
110
111
Channel
4
5
6
7
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TS: Transmit Template Select Register (R/W, Address = 11 Hex)
Symbol
Position
Default
-
TS.7-3
00000
TS[2-0]
TS.2-0
000
Description
0 = Normal operation. (Default)
1 = Reserved.
TS[2:0] select one of eight built-in transmit template for different applications.
TS[2:0]
Mode
Cable Length
000
E1
75 Ω coaxial cable/120 Ω twisted pair cable.
001
Reserved.
010
011
T1
0 - 133 ft.
100
T1
133 - 266 ft.
101
T1
266 - 399 ft.
110
T1
399 - 533 ft.
111
T1
533 - 655 ft.
OE: Output Enable Configuration Register (R/W, Address = 12 Hex)
Symbol
Position
Default
OE[7:0]
OE.7-0
00 H
Description
0 = Transmit drivers enabled. (Default)
1 = Transmit drivers placed in high impedance state.
AIS: Alarm Indication Signal Status Register (R, Address = 13 Hex)
Symbol
Position
AIS[7:0]
Default
AIS.7-0
00 H
Description
0 = Normal operation. (Default)
1 = AIS detected.
AISM : Alarm Indication Signal Interrupt Mask Register (R/W, Address = 14 Hex)
Symbol
Position
Default
AISM[7:0]
AISM.7-0
00 H
Description
0 = AIS interrupt is not allowed. (Default)
1 = AIS interrupt is allowed.
AISI: Alarm Indication Signal Interrupt Status Register (R, Address = 15 Hex)
Symbol
Position
Default
AISI[7:0]
AISI.7-0
00 H
Description
0 = (Default), or after an AIS read operation
1 = Any transition on AISn. (Corresponding AISMn is set to 1.)
ADDP: Address Pointer Control Register (R/W, Address = 1F Hex)
Symbol
Position
ADDP[7:0] ADDP.7-0
Default
00 H
Description
Two kinds of configuration in this register can be set to switch between primary register bank and expanded
register bank. When power up, the address pointer will point to the top address of primary register bank
automatically.
00H = The address pointer points to the top address of primary register bank (default).
AAH = The address pointer points to the top address of expanded register bank.
35
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
Expanded Register Description
e-SING: Single Rail Mode Setting Register (R/W, Expanded Address = 00 Hex)
Symbol
Position
Default
SING[7:0]
SING.7-0
00 H
Description
0 = Pin TDNn selects single rail mode or dual rail mode. (Default)
1 = Single rail mode enabled (with CRSn=0)
e-CODE: Encoder/Decoder Selection Register (R/W, Expanded Address = 01 Hex)
Symbol
Position
Default
CODE[7:0]
CODE.7-0
00 H
Description
Line Code Selection.
CODEn selects AMI or B8ZS/HDB3 encoder/decoder on per-channel basis with SINGn = 1 and
CRSn = 0.
0 = B8ZS/HDB3 encoder/decoder enabled. (Default)
1 = AMI encoder/decoder enabled.
e-CRS: Clock Recovery Enable/Disable Selection Register (R/W, Expanded Address = 02 Hex)
Symbol
Position
Default
CRS[7:0]
CRS.7-0
00 H
Description
0 = Clock recovery enabled. (Default)
1 = Clock recovery disabled.
e-RPDN: Receiver n Powerdown Register (R/W, Expanded Address = 03 Hex)
Symbol
RPDN[7:0]
Position
Default
RPDN.7-0
00 H
Description
0 = Normal operation. (Default)
1 = Power down in receiver n.
e-TPDN: Transmitter n Powerdown Register (R/W, Expanded Address = 04 Hex)
Symbol
Position
Default
TPDN[7:0]
TPDN.7-0
00 H
Description
0 = Normal operation. (Default)
1 = Power down in Transmitter n (the corresponding transmit output driver enters a low power high
impedance mode).
Note that transmitter n is power down when either pin TCLKn is pulled to low or TPDNn is set to 1.
e-CZER: Consecutive Zero Detect Enable/Disable Register (R/W, Expanded Address = 05 Hex)
Symbol
Position
Default
CZER[7:0]
CZER.7-0
00 H
Description
0 = Excessive zero detect disabled. (Default)
1 = Excessive zero detect enabled for B8ZS/HDB3 decoder in single rail mode.
e-CODV: Code Violation Detect Enable/Disable Register (R/W, Expanded Address = 06 Hex)
Symbol
Position
Default
CODV[7:0]
CODV.7-0
00 H
Description
0 = Code Violation Detect enable for B8ZS/HDB3 decoder in single rail mode. (Default)
1 = Code Violation Detect disable.
e-EQUA: Receive Equalizer Enable/Disable Register (R/W, Expanded Address = 07 Hex)
Symbol
Position
Default
Description
EQUA[7:0]
EQUA.7-0
00 H
0 = Normal operation. (Default)
1 = Equalizer in Receiver n enabled, which can improved the receive performance when
transmission length is more than 200 m.
36
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
e-LBCF: Inband Loopback Configuration Register (R/W, Expanded Address = 08 Hex)
Symbol
Position
Default
-
LBCF.7-6
000
LBDE
LBCF.5
0
ALBE
LBCF.4
0
LBAL[1:0]
LBCF.3-2
00
LBDL[1:0]
LBCF.1-0
00
Description
0 = Normal Operation. (Default)
1 = Reserved.
Loopback Detector Enable
0 = Inband loopback code detection is disabled. (Default)
1 = Inband loopback code detection is enabled.
Automatic Loopback Enable.
0 = Automatic Inband Loopback disabled.
1 = Automatic Inband Loopback enabled.
Loopback Activation Code Length.
00 = 5-bit long activation code in LBAC[7:3] is effective.
01 = 6-bit long activation code in LBAC[7:2] is effective.
10 = 7-bit long activation code in LBAC[7:1] is effective.
11 = 8-bit long activation code in LBAC[7:0] is effective.
Loopback Deactivation Code Length.
00 = 5-bit long deactivation code in LBDC[7:3] is effective.
01 = 6-bit long deactivation code in LBDC[7:2] is effective.
10 = 7-bit long deactivation code in LBDC[7:1] is effective.
11 = 8-bit long deactivation code in LBDC[7:0] is effective.
Note that all these bits in e-LBCF are global control.
e-LBAC: Inband Loopback Activation Code Register (R/W, Expanded Address = 09 Hex)
Symbol
Position
Default
LBAC[7:0]
LBAC.7-0
00 H
Description
LBAC[7:0] = 8-bit (or 4-bit) repeating activate code is programmed with the length limitation in LBAL[1:0].
LBAC[7:1] = 7-bit repeating activate code is programmed with the length limitation in LBAL[1:0].
LBAC[7:2] = 6-bit (or 3-bit) repeating activate code is programmed with the length limitation in LBAL[1:0].
LBAC[7:3] = 5-bit repeating activate code is programmed with the length limitation in LBAL[1:0].
Note1: when setting a value in e-LBAC or e-LBDC that is less than 8-bits, the most significant bits must
be replicated in the unused least significant bits. e.g. if setting a 5-bit code = 11000, the register value
should be 11000110. Here b7 is repeated in b2; b6 is repeated in b1; b5 is repeated in bo.
Note2: this register is global control.
e-LBDC: Inband Loopback Deactivation Code Register (R/W, Expanded Address = 0A Hex)
Symbol
Position
Default
LBDC[7:0]
LBDC.7-0
00 H
Description
LBDC[7:0] = 8-bit (or 4-bit) repeating deactivate code is programmed with the length limitation in LBDL[1:0].
LBDC[7:1] = 7-bit repeating deactivate code is programmed with the length limitation in LBDL[1:0].
LBDC[7:2] = 6-bit (or 3-bit) repeating deactivate code is programmed with the length limitation in LBDL[1:0].
LBDC[7:3] = 5-bit repeating deactivate code is programmed with the length limitation in LBDL[1:0].
Note that this register is global control.
e-LBS: Inband Loopback Receive Status Register (R, Expanded Address = 0B Hex)
Symbol
Position
Default
LBS[7:0]
LBS.7-0
00 H
Description
0 = Normal operation (Default). Or loopback deactivation code detected .
1 = Loopback activation code detected.
e-LBM: Inband Loopback Interrupt Mask Register (R/W, Expanded Address = 0C Hex)
Symbol
Position
Default
LBM[7:0]
LBM.7-0
00 H
Description
0 = LBI interrupt is not allowed (Default)
1 = LBI interrupt is allowed.
37
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
e-LBI: Inband Loopback Interrupt Status Register (R, Expanded Address = 0D Hex)
Symbol
Position
Default
LBI[7:0]
LBI.7-0
00 H
Description
0 = (Default). Or after a read of e-LBS operation.
1 = Any transition on e-LBSn. (Corresponding e-LBMn and bit LBDE in e-LBCF are both set to 1.)
e-LBGS: Inband Loopback Activation/Deactivation Code Generator Selection Register (R/W, Expanded Address = 0E Hex)
Symbol
Position
Default
LBGS[7:0]
LBGS.7-0
00 H
Description
0 = Activation Code Generator is selected in transmitter n. (Default)
1 = Deactivation Code Generator is selected in transmitter n.
e-LBGE: Inband Loopback Activation/Deactivation Code Generator Enable Register (R/W, Expanded Address = 0F Hex)
Symbol
Position
Default
LBGE[7:0]
LBGE.7-0
00 H
Description
0 = Activation/ Deactivation Code Generator for inband loopback is disabled in transmitter n. (Default)
1 = Activation/Deactivation Code Generator for inband loopback is enabled in transmitter n.
Reserved Registers: Primary Registers 16 - 1E and are reservered.
Test Registers: Expand Registers 10 - 1E are test registers. They must be set to 0.
38
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
IEEE STD 1149.1 JTAG TEST ACCESS PORT
The JTAG boundary scan registers includes BSR (Boundary Scan
Register), IDR (Device Identification Register), BR (Bypass Register)
and IR (Instruction Register). These will be described in the following
pages. Refer to Figure-21 for architecture.
The IDT82V2048 supports the digital Boundary Scan Specification
as described in the IEEE 1149.1 standards.
The boundary scan architecture consists of data and instruction registers plus a Test Access Port (TAP) controller. Control of the TAP is
achieved through signals applied to the Test Mode Select (TMS) and
Test Clock (TCK) input pins. Data is shifted into the registers via the Test
Data Input (TDI) pin, and shifted out of the registers via the Test Data
Output (TDO) pin. Both TDI and TDO are clocked at a rate determined
by TCK.
Digital output pins
INDUSTRIAL TEMPERATURE RANGES
JTAG INSTRUCTIONS AND INSTRUCTION REGISTER (IR)
The IR (Instruction Register) with instruction decode block is used to
select the test to be executed or the data register to be accessed or
both.
The instructions are shifted in LSB first to this 3-bit register. See
Table-17 for details of the codes and the instructions related.
Digital input pins
parallel latched output
BSR (Boundary Scan Register)
MUX
IDR (Device Identification Register)
TDI
MUX
BR (Bypass Register)
IR (Instruction Register)
Control<6:0>
TMS
TRST
TAP
(Test Access Port)
Controller
Select
Tristate Enable
TCK
Figure - 21. JTAG Architecture
39
TDO
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TABLE - 17. INSTRUCTION REGISTER DESCRIPTION
IR CODE
INSTRUCTION
000
Extest
100
Sample / Preload
110
Idcode
111
Bypass
COMMENTS
The external test instruction allows testing of the interconnection to other devices. When the current
instruction is the EXTEST instruction, the boundary scan register is placed between TDI and TDO. The
signal on the input pins can be sampled by loading the boundary scan register using the Capture-DR state.
The sampled values can then be viewed by shifting the boundary scan register using the Shift-DR state.
The signal on the output pins can be controlled by loading patterns shifted in through input TDI into the
boundary scan register using the Update-DR state.
The sample instruction samples all the device inputs and outputs. For this instruction, the boundary scan
register is placed between TDI and TDO. The normal path between IDT82V2048 logic and the I/O pins is
maintained. Primary device inputs and outputs can be sampled by loading the boundary scan register using
the Capture-DR state. The sampled values can then be viewed by shifting the boundary scan register using
the Shift-DR state.
The identification instruction is used to connect the identification register between TDI and TDO. The
device's identification code can then be shifted out using the Shift-DR state.
The bypass instruction shifts data from input TDI to output TDO with one TCK clock period delay. The
instruction is used to bypass the device.
Bypass Register (BR)
The BR consists of a single bit. It can provide a serial path between
the TDI input and TDO output, bypassing the BSR to reduce test access
times.
TABLE - 18. DEVICE IDENTIFICATION REGISTER DESCRIPTION
BIT No.
0
1~11
12~27
28~31
COMMENTS
Set to “1”
Producer Number
Part Number
Device Revision
Boundary Scan Register (BSR)
The BSR can apply and read test patterns in parallel to or from all
the digital I/O pins. The BSR is a 98 bits long shift register and is
initialized and read using the instruction EXTEST or SAMPLE/
PRELOAD. Each pin is related to one or more bits in the BSR. Please
refer to Table-19 for details of BSR bits and their functions.
JTAG DATA REGISTER
Device Identification Register (IDR)
The IDR can be set to define the producer number, part number and
the device revision, which can be used to verify the proper version or
revision number that has been used in the system under test. The IDR is
32 bits long and is partitioned as in Table-18. Data from the IDR is
shifted out to TDO LSB first.
TEST ACCESS PORT CONTROLLER
The TAP controller is a 16-state synchronous state machine. Figure22 shows its state diagram A description of each state follows. Note
that the figure contains two main branches to access either the data or
instruction registers. The value shown next to each state transition in
this figure states the value present at TMS at each rising edge of TCK.
Please refer to Table-20 for details of the state description.
TABLE - 19. BOUNDARY SCAN REGISTER DESCRIPTION
BIT No.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
BIT SYMBOL
POUT0
PIN0
POUT1
PIN1
POUT2
PIN2
POUT3
PIN3
POUT4
PIN4
POUT5
PIN5
POUT6
PIN6
POUT7
PIN SIGNAL
LP0
LP0
LP1
LP1
LP2
LP2
LP3
LP3
LP4
LP4
LP5
LP5
LP6
LP6
LP7
TYPE
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
COMMENTS
40
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TABLE - 19. BOUNDARY SCAN REGISTER DESCRIPTION (CONTINUED)
BIT No.
15
16
BIT SYMBOL
PIN7
PIOS
PIN SIGNAL
LP7
N/A
TYPE
I/O
-
17
18
19
20
21
22
23
TCLK1
TDP1
TDN1
RCLK1
RDP1
RDN1
HZEN1
TCLK1
TDP1
TDN1
RCLK1
RDP1
RDN1
N/A
I
I
I
O
O
O
-
24
25
26
27
28
29
30
31
LOS1
TCLK0
TDP0
TDN0
RCLK0
RDP0
RDN0
HZEN0
LOS1
TCLK0
TDP0
TDN0
RCLK0
RDP0
RDN0
N/A
O
I
I
I
O
O
O
-
32
33
34
35
36
37
LOS0
MODE1
LOS3
RDN3
RDP3
HZEN3
LOS0
MODE1
LOS3
RDN3
RDP3
N/A
O
I
O
O
O
-
38
39
40
41
42
43
44
45
RCLK3
TDN3
TDP3
TCLK3
LOS2
RDN2
RDP2
HZEN2
RCLK3
TDN3
TDP3
TCLK3
LOS2
RDN2
RDP2
N/A
O
I
I
I
O
O
O
-
46
47
48
49
50
51
52
RCLK2
TDN2
TDP2
TCLK2
INT
ACK
SDORDYS
RCLK2
TDN2
TDP2
TCLK2
INT
ACK
N/A
O
I
I
I
O
O
-
53
54
55
WRB
RDB
ALE
DS
R/W
ALE
I
I
I
COMMENTS
Controls pin LP7~0.
When “0”, the pins are configured as outputs. The output
values to the pins are set in POUT7~0.
When “1”, the pins are tristated. The input values to the
pins are read in PIN7~0.
Controls pin RDP1, RDN1 and RCLK1.
When “0”, the outputs are enabled on the pins.
When “1”, the pins are tristated.
Controls pin RDP0, RDN0 and RCLK0.
When “0”, the outputs are enabled on the pins.
When “1”, the pins are tristated.
Controls pin RDP3, RDN3 and RCLK3.
When “0”, the outputs are enabled on the pins.
When “1”, the pins are tristated.
Controls pin RDP2, RDN2 and RCLK2.
When “0”, the outputs are enabled on the pins.
When “1”, the pins are tristated.
Control pin ACK.
When “0”, the output is enabled on pin ACK .
When “1”, the pin is tristated.
41
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TABLE - 19. BOUNDARY SCAN REGISTER DESCRIPTION (CONTINUED)
BIT No.
56
57
58
59
60
61
62
63
64
BIT SYMBOL
CSB
MODE0
TCLK5
TDP5
TDN5
RCLK5
RDP5
RDN5
HZEN5
PIN SIGNAL
CS
MODE0
TCLK5
TDP5
TDN5
RCLK5
RDP5
RDN5
N/A
TYPE
I
I
I
I
I
O
O
O
-
65
66
67
68
69
70
71
72
LOS5
TCLK4
TDP4
TDN4
RCLK4
RDP4
RDN4
HZEN4
LOS5
TCLK4
TDP4
TDN4
RCLK4
RDP4
RDN4
N/A
O
I
I
I
O
O
O
-
73
74
75
76
77
78
79
LOS4
OE
CLKE
LOS7
RDN7
RDP7
HZEN7
LOS4
OE
CLKE
LOS7
RDN7
RDP7
N/A
O
I
I
O
O
O
-
80
81
82
83
84
85
86
87
RCLK7
TDN7
TDP7
TCLK7
LOS6
RDN6
RDP6
HZEN6
RCLK7
TDN7
TDP7
TCLK7
LOS6
RDN6
RDP6
N/A
O
I
I
I
O
O
O
-
88
89
90
91
92
93
94
95
96
97
98
RCLK6
TDN6
TDP6
TCLK6
MCLK
MODE2
A4
A3
A2
A1
A0
RCLK6
TDN6
TDP6
TCLK6
MCLK
MODE2
A4
A3
A2
A1
A0
O
I
I
I
I
I
I
I
I
I
I
COMMENTS
Controls pin RDP5, RDN5 and RCLK5.
When “0”, the outputs are enabled on the pins.
When “1”, the pins are tristated.
Controls pin RDP4, RDN4 and RCLK4.
When “0”, the outputs are enabled on the pins.
When “1”, the pins are tristated.
Controls pin RDP7, RDN7 and RCLK7.
When “0”, the outputs are enabled on the pins.
When “1”, the pins are tristated.
Controls pin RDP6, RDN6 and RCLK6.
When “0”, the outputs are enabled on the pins.
When “1”, the pins are tristated.
42
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TABLE - 20. TAP CONTROLLER STATE DESCRIPTION
STATE
Test Logic
Reset
Run-Test/Idle
Select-DR-Scan
Capture-DR
Shift-DR
Exit1-DR
Pause-DR
Exit2-DR
Update-DR
Select-IR-Scan
Capture-IR
Shift-IR
DESCRIPTION
In this state, the test logic is disabled. The device is set to normal operation. During initialization, the device initializes the
instruction register with the IDCODE instruction.
Regardless of the original state of the controller, the controller enters the Test-Logic-Reset state when the TMS input is
held high for at least 5 rising edges of TCK. The controller remains in this state while TMS is high. The device processor
automatically enters this state at power-up.
This is a controller state between scan operations. Once in this state, the controller remains in the state as long as TMS is
held low. The instruction register and all test data registers retain their previous state. When TMS is high and a rising edge is
applied to TCK, the controller moves to the Select-DR state.
This is a temporary controller state and the instruction does not change in this state. The test data register selected by the
current instruction retains its previous state. If TMS is held low and a rising edge is applied to TCK when in this state, the
controller moves into the Capture-DR state and a scan sequence for the selected test data register is initiated. If TMS is held
high and a rising edge applied to TCK, the controller moves to the Select-IR-Scan state.
In this state, the Boundary Scan Register captures input pin data if the current instruction is EXTEST or
SAMPLE/PRELOAD. The instruction does not change in this state. The other test data registers, which do not have parallel
input, are not changed. When the TAP controller is in this state and a rising edge is applied to TCK, the controller enters the
Exit1-DR state if TMS is high or the Shift-DR state if TMS is low.
In this controller state, the test data register connected between TDI and TDO as a result of the current instruction shifts
data on stage toward its serial output on each rising edge of TCK. The instruction does not change in this state. When the
TAP controller is in this state and a rising edge is applied to TCK, the controller enters the Exit1-DR state if TMS is high or
remains in the Shift-DR state if TMS is low.
This is a temporary state. While in this state, if TMS is held high, a rising edge applied to TCK causes the controller to
enter the Update-DR state, which terminates the scanning process. If TMS is held low and a rising edge is applied to TCK,
the controller enters the Pause-DR state. The test data register selected by the current instruction retains its previous value
and the instruction does not change during this state.
The pause state allows the test controller to temporarily halt the shifting of data through the test data register in the serial
path between TDI and TDO. For example, this state could be used to allow the tester to reload its pin memory from disk
during application of a long test sequence. The test data register selected by the current instruction retains its previous value
and the instruction does not change during this state. The controller remains in this state as long as TMS is low. When TMS
goes high and a rising edge is applied to TCK, the controller moves to the Exit2-DR state.
This is a temporary state. While in this state, if TMS is held high, a rising edge applied to TCK causes the controller to
enter the Update-DR state, which terminates the scanning process. If TMS is held low and a rising edge is applied to TCK,
the controller enters the Shift-DR state. The test data register selected by the current instruction retains its previous value and
the instruction does not change during this state.
The Boundary Scan Register is provided with a latched parallel output to prevent changes while data is shifted in response
to the EXTEST and SAMPLE/PRELOAD instructions. When the TAP controller is in this state and the Boundary Scan
Register is selected, data is latched into the parallel output of this register from the shift-register path on the falling edge of
TCK. The data held at the latched parallel output changes only in this state. All shift-register stages in the test data register
selected by the current instruction retain their previous value and the instruction does not change during this state.
This is a temporary controller state. The test data register selected by the current instruction retains its previous state. If
TMS is held low and a rising edge is applied to TCK when in this state, the controller moves into the Capture-IR state, and a
scan sequence for the instruction register is initiated. If TMS is held high and a rising edge is applied to TCK, the controller
moves to the Test-Logic-Reset state. The instruction does not change during this state.
In this controller state, the shift register contained in the instruction register loads a fixed value of ‘100’ on the rising edge
of TCK. This supports fault-isolation of the board-level serial test data path. Data registers selected by the current instruction
retain their value and the instruction does not change during this state. When the controller is in this state and a rising edge is
applied to TCK, the controller enters the Exit1-IR state if TMS is held high, or the Shift-IR state if TMS is held low.
In this state, the shift register contained in the instruction register is connected between TDI and TDO and shifts data one
stage towards its serial output on each rising edge of TCK. The test data register selected by the current instruction retains its
previous value and the instruction does not change during this state. When the controller is in this state and a rising edge is
applied to TCK, the controller enters the Exit1-IR state if TMS is held high, or remains in the Shift-IR state if TMS is held low.
43
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TABLE - 21. TAP CONTROLLER STATE DESCRIPTION (CONTINUED)
STATE
Exit1-IR
Pause-IR
Exit2-IR
Update-IR
DESCRIPTION
This is a temporary state. While in this state, if TMS is held high, a rising edge applied to TCK causes the controller to
enter the Update-IR state, which terminates the scanning process. If TMS is held low and a rising edge is applied to TCK, the
controller enters the Pause-IR state. The test data register selected by the current instruction retains its previous value and
the instruction does not change during this state.
The pause state allows the test controller to temporarily halt the shifting of data through the instruction register. The test
data register selected by the current instruction retains its previous value and the instruction does not change during this
state. The controller remains in this state as long as TMS is low. When TMS goes high and a rising edge is applied to TCK,
the controller moves to the Exit2-IR state.
This is a temporary state. While in this state, if TMS is held high, a rising edge applied to TCK causes the controller to
enter the Update-IR state, which terminates the scanning process. If TMS is held low and a rising edge is applied to TCK, the
controller enters the Shift-IR state. The test data register selected by the current instruction retains its previous value and the
instruction does not change during this state.
The instruction shifted into the instruction register is latched into the parallel output from the shift-register path on the falling
edge of TCK. When the new instruction has been latched, it becomes the current instruction. The test data registers selected
by the current instruction retain their previous value.
1
Test-logic Reset
0
0
Run Test/Idle
1
Select-DR
1
Select-IR
0
1
0
1
Capture-DR
Capture-IR
0
0
0
0
Shift-DR
Shift-IR
1
1
1
Exit1-DR
1
Exit1-IR
0
0
0
0
Pause-DR
Pause-IR
1
0
1
0
Exit2-DR
Exit2-IR
1
1
Update-DR
0
1
Figure - 22. JTAG State Diagram
44
1
Update-IR
1
0
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
ABSOLUTE MAXIMUM RATING
Symbol
VDDA,VDDD
VDDIO0,VDDIO1
VDDT0-7
Parameter
Core Power Supply
I/O Power Supply
Transmit Power Supply
Input Voltage, Any Digital Pin
Min
-0.5
-0.5
-0.5
GND-0.5
Vin
Input Voltage, Any RTIP and RRING pin (1)
GND-0.5
Max
4.0
4.0
7.0
5.5
VDDA+0.5
VDDD+0.5
Unit
V
V
V
V
V
ESD Voltage, any pin (2)
2000
V
Transient latch-up current, any pin
100
mA
Input current, any digital pin (3)
-10
10
mA
Iin
(3)
±
DC Input current, any analog pin
100
mA
Pd
Maximum power dissipation in package
1.6
W
°C
Tc
Case Temperature
120
°C
Ts
Storage Temperature
-65
+150
CAUTION
Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied.
Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
NOTE:
1. Referenced to ground
2. Human body model
3. Constant input current
RECOMMENDED OPERATING CONDITIONS
Symbol
VDDA,VDDD
VDDIO
VDDT
TA
RL
IVDD
IVDDIO
IVDDT
Parameter
Core Power Supply
I/O Power Supply
Transmitter Supply
3.3V
5V
Ambient operating temperature
Output load at TTIP and TRING
Average core power supply current (1)
IO power supply current (4)
Average transmitter power supply current, T1
mode (1, 2, 3)
50% ones density data:
100% ones density data:
Min
3.13
3.13
Typ
3.3
3.3
Max
3.47
3.47
Unit
V
V
3.13
4.75
-40
25
3.3
5.0
25
3.47
5.25
85
55
15
65
25
V
V
°C
Ω
mA
mA
NOTE:
1. Maximum power and current consumption over the full operating temperature and power supply voltage range. Includes all channels.
2. Power consumption includes power absorbed by line load and external transmitter components.
3. T1 maximum values measured with maximum cable length (LEN = 111). Typical values measured with typical cable length (LEN = 101).
4. Digital output is driving 50pF load, digital input is within 10% of the supply rails.
45
230
440
mA
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
POWER CONSUMPTION
Symbol
Parameter
E1, 3.3V, 75 Ω Load
50% ones density data:
100% ones density data:
E1, 3.3V, 120 Ω Load
50% ones density data:
100% ones density data:
E1, 5.0V, 75 Ω Load
50% ones density data:
100% ones density data:
E1, 5.0V, 120 Ω Load
50% ones density data:
100% ones density data:
T1, 3.3V, 100 Ω Load (3)
50% ones density data:
100% ones density data:
T1, 5.0V, 100 Ω Load (3)
50% ones density data:
100% ones density data:
LEN
Min
Typ
Max(1, 2)
Unit
000
000
-
662
1100
1177
mW
000
000
-
576
930
992
mW
000
000
-
910
1585
1690
mW
000
000
-
785
1315
1410
mW
101
111
-
820
1670
1792
mW
101
111
-
1185
2395
2670
mW
Max
Unit
1
3 VDDIO-0.2
0.8
V
2
VDDIO-0.2
3
V
NOTE:
1. Maximum power and current consumption over the full operating temperature and power supply voltage range. Includes all channels.
2. Power consumption includes power absorbed by line load and external transmitter components.
3. T1 maximum values measured with maximum cable length (LEN = 111). Typical values measured with typical cable length (LEN = 101).
DC CHARACTERISTICS
Symbol
VIL
Parameter
Input Low Level Voltage
Min
Typ
MODE2, JAS, LPn pins
VIM
All other digital inputs pins
Input Mid Level Voltage
1
VDDIO+0.2
3
MODE2, JAS, LPn pins
VIH
Input High Voltage
MODE2, JAS, LPn pins
VOL
VOH
VMA
IH
IL
II
IZL
Z OH
1
2 VDDIO
All other digital inputs pins
Output Low level Voltage (1)
(Iout=1.6mA)
Output High level Voltage (1)
(Iout=400µA)
Analog Input Quiescent Voltage
(RTIP, RRING pin while floating)
Input High Level Current
(MODE2, JAS, LPn pin)
Input Low Level Current
(MODE2, JAS, LPn pin)
Input Leakage Current
TMS, TDI, TRST
All other digital input pins
Tri-state Leakage Current
Output High Impedance on (TTIP, TRING Pins)
NOTE:
1. Output drivers will output CMOS logic levels into CMOS loads.
46
2
3 VDDIO+ 0.2
2.0
V
2.4
1.33
-10
-10
150
1.4
0.4
V
VDDIO
V
1.47
V
50
µA
50
µA
50
10
10
µA
µA
µA
KΩ
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TRANSMITTER CHARACTERISTICS
Symbol
Parameter
V0-p
Output pulse amplitudes (1)
E1, 75 Ω load
E1,120Ω load
T1,100 Ω load
VO-S
Zero (space) level
E1, 75 Ω load
E1,120 Ω load
T1,100 Ω load
Transmit amplitude variation with supply
Difference between pulse sequences for 17 consecutive pulses
T PW
Output Pulse Width at 50% of nominal amplitude
E1:
T1:
Ratio of the amplitudes of Positive and Negative Pulses at the
center of the pulse interval
RTX
Transmit Return Loss (2)
51 KHz – 102 KHz
E1,75 Ω
102 KHz - 2.048 MHz
2.048 MHz – 3.072 MHz
51 KHz – 102 KHz
E1,120Ω
102 KHz - 2.048 MHz
2.048 MHz – 3.072 MHz
51 KHz – 102 KHz
T1
102 KHz - 2.048 MHz
(VDDT=5V)
2.048 MHz – 3.072 MHz
JTXP-P
Intrinsic Transmit Jitter (TCLK is jitter free, JA enable)
E1: 20 HZ – 100 KHz
T1: 10 Hz – 8 KHz
8 KHz – 40 KHz
10 Hz – 40 KHz
wide band
Td
Transmit path delay
(JA is disabled)
Single rail
Dual rail
ISC
Line short circuit current (3)
NOTE:
1. E1:measured at the line output ports; T1: measured at the DSX
2. Test at IDT82V2048 evaluation board
3. Measured at 2x9.5Ω series resistors and 1:2 transformer
47
Min
Typ
Max
Unit
2.14
2.7
2.4
2.37
3.0
3.0
2.6
3.3
3.6
V
V
V
-0.237
-0.3
-0.15
0.237
0.3
0.15
V
V
V
-1
+1
200
%
mV
256
362
ns
ns
232
338
244
350
0.95
1.05
15
15
15
15
15
15
15
15
15
dB
dB
dB
dB
dB
dB
dB
dB
dB
0.050
0.020
0.025
0.025
0.050
U.I.
U.I.p-p
U.I.p-p
U.I.p-p
U.I.p-p
8
3
U.I.
U.I.
mA
Ip-p
150
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
RECEIVER CHARACTERISTICS
Symbol
ATT
IA
SIR
SRE
JRX p-p
JTRX
ZDM
ZCM
RRX
Parameter
Permissible Cable Attenuation
(E1:@1024kHz, T1:@772KHz)
Input Amplitude
Signal to Interference Ratio Margin (1)
Data decision threshold (reference to peak input voltage)
Data slicer threshold
Analog loss of signal (2)
Threshold:
Hysteresis:
Allowable consecutive zeros before LOS
E1, G.775:
E1, ETSI300233:
T1, T1.231-1993
LOS reset
Clock recovery mode
Peak to Peak Intrinsic Receive Jitter (JA disabled)
E1 (wide band):
T1 (wide band):
Jitter Tolerance
E1: 1 Hz – 20 Hz
20 Hz – 2.4 KHz
18 KHz – 100 KHz
T1: 0.1 Hz – 1 Hz
4.9 Hz – 300 Hz
10 KHz – 100 KHz
Receiver Differential Input Impedance
Receiver Common Mode Input Impedance to GND
Receive Return Loss
51 KHz – 102 KHz
102 KHz - 2.048 MHz
2.048 MHz – 3.072 MHz
Receive path delay
Dual rail
Single rail
Min
Typ
Max
15
Unit
dB
0.8
50
150
Vp
dB
%
mV
310
230
mV
mV
0.1
-14
32
2048
175
12.5
% ones
0.0625
0.0625
18.0
1.5
0.2
138.0
28.0
0.4
U.I.
U.I.
10
U.I.
U.I.
U.I.
U.I.
U.I.
U.I.
KΩ
KΩ
20
20
20
db
dB
dB
120
3
8
U.I.
U.I.
NOTE:
1. E1: per G.703, O.151 @6dB cable attenuation. T1: @655ft. of 22ABAM cable
2. The test circuit for this parameter is shown in Figure 12. The analog signal is measured on the Receiver line before the transformer (port A and port B in Figure 12).
And the receive line is a T1/E1 cable simulator.
48
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
JITTER ATTENUATOR CHARACTERISTICS
Symbol
Parameter
f-3dB
Jitter Transfer Function Corner (–3dB) Frequency
Host mode
E1, 32/64 bit FIFO
JABW = 0:
JABW = 1:
T1, 32/64 bit FIFO
JABW = 0:
JABW = 1:
Hardware mode
E1
T1
Jitter Attenuator
E1: (1)
@ 3 Hz
@ 40 Hz
@ 400 Hz
@ 100kHz
T1: (2)
@ 1 Hz
@ 20 Hz
@ 1kHz
@ 1.4kHz
@ 70kHz
td
Jitter Attenuator Latency Delay
32bit FIFO:
64bit FIFO:
Input jitter tolerance before FIFO overflow or underflow
32bit FIFO:
64bit FIFO:
Output jitter in remote loopback (3)
NOTE:
1. Per G.736, see Fig-38.
2. Per AT&T pub.62411, see Fig-39.
3. Per ETSI CTR12/13 Output jitter.
49
Min
Typ
Max
Unit
1.7
6.6
Hz
Hz
2.5
5
1.7
2.5
Hz
Hz
Hz
Hz
-0.5
-0.5
+19.5
+19.5
dB
0
0
+33.3
40
40
dB
16
32
U.I.
U.I.
28
56
U.I.
U.I.
U.I.
0.11
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TRANSCEIVER TIMING CHARACTERISTICS
Symbol
Parameter
Min
MCLK frequency
E1:
T1:
MCLK tolerance
MCLK duty cycle
Typ
Max
2.048
1.544
-100
40
Unit
MHz
100
60
ppm
%
Transmit path
t1
t2
TCLK frequency
E1:
T1:
TCLK tolerance
TCLK Duty Cycle
Transmit Data Setup Time
Transmit Data Hold Time
Delay time of OE low to driver High Z
Delay time of TCLK low to driver High Z
2.048
1.544
-50
10
40
40
MHz
+50
90
1
48
ppm
%
ns
ns
us
us
40
44
40
+/- 80
+/- 180
50
60
%
457
607
488
648
519
689
ns
203
259
244
324
285
389
ns
203
259
20
244
324
285
389
ns
200
200
244
324
ns
200
200
244
324
ns
200
300
244
324
ns
Receive path
Clock recovery capture range (1)
E1
T1
RCLK duty cycle
RCLK pulse width (2)
E1:
T1:
RCLK pulse width low time
E1:
T1:
RCLK pulse width high time
E1:
T1:
Rise/fall time (3)
Receive Data Setup Time
E1:
T1:
Receive Data Hold Time
E1:
T1:
RDN/RDP pulse width (MCLK = H) (4)
E1:
T1:
(2)
t4
t5
t6
t7
t8
t9
ppm
ns
NOTE:
1. Relative to nominal frequency, MCLK=+/-100 ppm
2. RCLK duty cycle widths will vary depending on extent of received pulse jitter displacement. Maximum and minimum RCLK duty cycles are for worst case jitter conditions (0.2UI
displacement for E1 per ITU G.823).
3. For all digital outputs. C load = 15 pF
4. Clock recovery is disabled in this mode.
50
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
TCLK
t1
t2
TNn/TDPn
TDNn/BPVIn
Figure - 24. Transmit System Interface Timing
t4
RCLK
t6
t5
t7
t8
RDPn/RDn
(CLKE = 1)
RDNn/CVn
t7
RDPn/RDn
(CLKE = 0)
RDNn/CVn
Figure - 25. Receive System Interface Timing
51
t8
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
JTAG TIMING CHARACTERISTICS
Symbol
Parameter
t1
TCK Period
t2
TMS to TCK setup Time
TDI to TCK Setup Time
t3
TCK to TMS Hold Time
TCK to TDI Hold Time
t4
TCK to TDO Delay Time
Min
200
Typ
ns
50
ns
100
TCK
t3
TMS
TDI
t4
TDO
Figure - 26. JTAG Interface Timing
52
Unit
ns
50
t1
t2
Max
ns
Comments
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
PARALLEL HOST INTERFACE TIMING CHARACTERISTICS
INTEL MODE READ TIMING CHARACTERISTICS
Parameter
Min Typ Max
90
Active RD Pulse Width
0
Active CS to Active RD Setup Time
0
RD
CS
Inactive
to Inactive
Hold Time
Valid Address to Inactive ALE Setup Time (in Multiplexed Mode)
5
0
Invalid RD to Address Hold Time (in Non-Multiplexed Mode)
7.5
15
Active RD to Data Output Enable Time
7.5
15
Inactive RD to Data Tri-State Delay Time
6
12
Active CS to RDY delay time
6
12
Inactive CS to RDY Tri-state Delay Time
20
Inactive RD to Inactive INT Delay Time
Address Latch Enable Pulse Width (in Multiplexed Mode)
10
0
Address Latch Enable to RD Setup Time (in Multiplexed Mode)
Address Setup time to Valid Data Time (in Non-Multiplexed Mode)
18
32
Inactive ALE to Valid Data Time (in Multiplexed Mode)
t14
10
15
Inactive RD to Active RDY Delay Time
t15
30
85
Active RD to Active RDY Delay Time
t16
Inactive ALE to Address Hold Time (in Multiplexed Mode)
5
Note 1: the t1 is determined by the start time of the valid data when the RDY signal is not used.
Symbol
t1
t2
t3
t4
t5
t6
t7
t8
t9
t10
t11
t12
t13
53
Unit Comments
ns
note 1
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
t2
CS
t3
t1
RD
ALE(=1)
t13
t5
ADDRESS
A[7:0]
t6
t7
DATA OUT
D[7:0]
t14
t8
t9
RDY
t15
t10
INT
Figure - 27. Non-Multiplexed Intel Mode Read Timing
t2
CS
t3
t1
RD
t11
t12
t13
ALE
t16
t4
AD[7:0]
t6
t7
ADDRESS
DATA OUT
t14
t8
t9
RDY
t15
t10
INT
Figure - 28. Multiplexed Intel Mode Read Timing
54
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
INTEL MODE WRITE TIMING CHARACTERISTICS
Symbol
Parameter
t1
WR
Active
Pulse Width
t2
Active CS to Active WR Setup Time
t3
Inactive WR to Inactive CS Hold Time
t4
Valid Address to Latch Enable Setup Time (in Multiplexed Mode)
t5
Invalid WR to Address Hold Time (in Non-Multiplexed Mode)
t6
Valid Data to Inactive WR Setup Time
t7
Inactive WR to Data Hold Time
t8
Active CS to Inactive RDY Delay Time
t9
Active WR to Active RDY Delay Time
t10
Inactive WR to Inactive RDY Delay Time
t11
Invalid CS to RDY Tri-State Delay Time
t12
Address Latch Enable Pulse Width (in Multiplexed Mode)
t13
Inactive ALE to WR Setup Time (in Multiplexed Mode)
t14
Inactive ALE to Address hold time (in Multiplexed Mode)
t15
Address setup time to Inactive WR time (in Non-Multiplexed Mode)
Note 1: the t1 can be 15ns when RDY signal is not used.
Min
90
0
0
5
2
5
10
6
30
10
6
10
0
5
5
Typ Max Unit Comments
ns
note 1
ns
ns
ns
ns
ns
ns
12
ns
85
ns
15
ns
12
ns
ns
ns
ns
ns
CS
t2
t1
t3
WR
ALE(=1)
t15
t5
ADDRESS
A[7:0]
t6
t7
WRITE DATA
D[7:0]
t10
t8
t11
RDY
t9
Figure - 29. Non-Multiplexed Intel Mode Write Timing
t2
CS
t3
t1
WR
t12
t13
ALE
t14
t4
AD[7:0]
t6
ADDRESS
t8
t7
WRITE DATA
t11
t9
RDY
t10
Figure - 30. Multiplexed Intel Mode Write Timing
55
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
MOTOROLA MODE READ TIMING CHARACTERISTICS
Symbol
t1
t2
t3
t4
t5
t6
Parameter
Min Typ Max Unit Comments
90
ns
note 1
Active DS Pulse Width
0
ns
Active CS to Active DS Setup Time
0
ns
Inactive DS to Inactive CS Hold Time
0
ns
Valid R/W to Active DS Setup Time
0.5
ns
DS
W
Inactive
to R/ Hold Time
ns
Valid Address to Active DS Setup Time (in Non-Multiplexed Mode)
5
Valid Address to AS Setup Time (in Multiplexed Mode)
t7
ns
Active DS to Address Hold Time (in Non-Multiplexed Mode)
10
Active AS to Address Hold Time (in Multiplexed Mode)
t8
ns
Active DS to Data Valid Delay Time (in Non-Multiplexed Mode)
20
35
Active AS to Data Valid Delay Time ( in Multiplexed Mode)
t9
7.5
15
ns
Active DS to Data Output Enable Time
t10
7.5
15
ns
Inactive DS to Data Tri-State Delay Time
t11
30
85
ns
Active DS to Active ACK Delay Time
t12
10
15
ns
Inactive DS to Inactive ACK Delay Time
t13
20
ns
Inactive DS to Invalid INT Delay Time
t14
5
ns
AS
DS
Active
to Active
Setup Time (in Multiplexed Mode)
Note 1: the t1 is determined by the start time of the valid data when the ACK signal is not used.
CS
t4
t5
R/W
t2
DS
ALE(=1)
A[7:0]
t1
t6
t3
t7
ADDRESS
t10
t8
DATA OUT
D[7:0]
t9
ACK
INT
t12
t11
t13
Figure - 31. Non-Multiplexed Motorola Mode Read Timing
CS
t2
t3
R/W
t1
t4
DS
t5
t14
AS
t6
AD[7:0]
t7
ADDRESS
t8
t9
t10
DATA OUT
t11
t12
ACK
t13
INT
Figure - 32. Multiplexed Motorola Mode Read Timing
56
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
MOTOROLA MODE WRITE TIMING CHARACTERISTICS
Symbol
t1
t2
t3
t4
t5
t6
Parameter
Active DS Pulse Width
Active CS to Active DS Setup Time
Inactive DS to Inactive CS Hold Time
Valid R/ W to Active DS Setup Time
Inactive DS to R/W Hold Time
Valid Address to Active DS Setup Time (in Non-Multiplexed Mode)
Valid Address to AS Setup Time (in Multiplexed Mode)
t7
Valid DS to Address Hold Time (in Non-Multiplexed Mode)
Valid AS to Address Hold Time (in Multiplexed Mode)
t8
Valid Data to Inactive DS Setup Time
t9
Inactive DS to Data Hold Time
t10
Active DS to Active ACK Delay Time
t11
Inactive DS to Inactive ACK Delay Time
t12
Active AS to Active DS (in Multiplexed Mode)
t13
Inactive DS to Inactive AS Hold Time ( in Multiplexed Mode)
Note 1: the t1 can be 15ns when the ACK signal is not used.
Min
90
0
0
10
0
10
Typ Max Unit Comments
ns
note 1
ns
ns
ns
ns
ns
ns
10
5
10
30
10
0
15
ns
ns
ns
ns
ns
ns
85
15
CS
t4
t5
R/W
t2
DS
ALE(=1)
t1
t6
t3
t7
ADDRESS
A[7:0]
t8
t9
WRITE DATA
D[7:0]
t10
t11
ACK
Figure - 33. Non-Multiplexed Motorola Mode Write Timing
CS
t2
t3
R/W
t4
DS
t1
t5
t12
t13
AS
t6
AD[7:0]
t8
t7
ADDRESS
t9
WRITE DATA
t10
ACK
Figure - 34. Multiplexed Motorola Mode Writing Timing
57
t11
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
SERIAL HOST INTERFACE TIMING CHARACTERISTICS
Symbol
t1
t2
t3
t4
t5
t6
t7
t8
t9
t10
t11
Parameter
SCLK High Time
SCLK Low Time
Active CS to SCLK Setup Time
Last SCLK Hold Time to Inactive CS Time
CS Idle Time
SDI to SCLK Setup Time
SCLK to SDI Hold Time
Rise/Fall Time (any pin)
SCLK Rise and Fall Time
SCLK to SDO Valid Delay Time
SCLK Falling Edge to SDO tri-state Hold Time (CLKE = 0)
CS Rising Edge to SDO tri-state Hold Time (CLKE = 1)
Min
25
25
10
50
50
5
5
Typ
Max
Unit Comments
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
100
50
100
100
CS
t3
t1
t4
t2
t5
SCLK
t6
SDI
t7
t7
LSB
LSB
MSB
CONTROL BYTE
DATA BYTE
Figure - 35. Serial Interface Write Timing
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
SCLK
t4
CS
t11
SDO
0
1
2
3
4
5
6
7
12
13
14
15
16
Figure - 36. Serial Interface Read Timing with CLKE = 0
1
2
3
4
5
6
7
8
9
10
11
SCLK
t4
CS
t11
SDO
0
1
2
3
Figure - 37. Serial Interface Read Timing with CLKE = 1
58
4
5
6
7
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
JITTER TOLERANCE PERFORMANCE
E1 JITTER TOLERANCE PERFORMANCE
1 10
3
100
G.823
IDT82V2048
Jitter (UI)
18 UI @ 1.8 Hz
10
1.5 UI @ 20 Hz
1
1.5 UI @ 2.4
kHz
0.2 UI @ 18 kHz
0.1
1
10
100
1 10
3
4
1 10
1 10
5
Frequency (Hz)
Figure - 38. E1 Jitter Tolerance Performance
Test condition: PRBS 2^15-1; Line code rule HDB3 is used.
T1 JITTER TOLERANCE PERFORMANCE
1 10
3
AT&T62411
IDT82V2048
Jitter (UI)
100
28 UI @ 4.9 Hz
28 UI @ 300 Hz
10
1
0.4 UI @ 10kHz
0.1
1
10
100
3
1 10
Frequency (Hz)
Figure - 39. T1 Jitter Tolerance Performance
Test condition: QRSS; Line code rule B8ZS is used.
59
1 10
4
5
1 10
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
JITTER TRANSFER PERFORMANCE
E1 JITTER TRANSFER PERFORMANCE
0.5 dB @ 3 Hz 0.5 dB @ 40 Hz
0
-20
-19.5 dB @ 20 kHz
Gain (dB)
G.736
-19.5 dB @
400 Hz
IDT82V2048
f3dB = 6.5 Hz
-40
-60
f3dB = 1.7 Hz
1
10
1 103
100
1 104
1 105
Frequency (Hz)
Figure - 40. E1 Jitter Transfer Performance
Test condition: PRBS 2^15-1; Line code rule HDB3 is used.
T1 JITTER TRANSFER PERFORMANCE
0 dB @ 1 Hz
0
-6 dB @
2 Hz
AT&T62411
GR-253-CORE
IDT82V2048
0.5 dB @ 350 Hz
0 dB @
20 Hz
f3dB = 2.5 Hz
Gain (dB)
TR-TSY-000009
-20
0.1 dB @ 40 Hz
-33.3 dB @ 1 kHz
-33.7 dB @ 2.5 kHz
-40 dB @ 1.4 kHz
f3dB = 5 Hz
-40
-40 dB @ 70 kHz
-49.2 dB @
15 kHz
-60 dB @
57 Hz
-60
1
10
100
1 103
Frequency (Hz)
Figure - 41. T1 Jitter Transfer Performance
Test condition: QRSS; Line code rule B8ZS is used.
60
1 104
1 105
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
INDUSTRIAL TEMPERATURE RANGES
ORDERING INFORMATION
IDT
XXXXXXX
Device Type
XX
X
Process/
Temperature
Range
Blank
Industrial (-40 °C to +85 °C)
BB
DA
Plastic Ball Grid Array (PBGA, BB160)
Thin Quad Flatpack (TQFP, DA144)
82V2048
T1/E1 Short Haul LIU
Data Sheet Document History
11/4/2001
11/20/2001
11/28/2001
11/29/2001
12/5/2001
12/24/2001
1/5/2002
1/24/2002
2/21/2002
3/25/2002
4/17/2002
5/7/2002
8/27/2002
1/15/2003
12/9/2003
pgs. 2, 3, 11, 19
pgs. 5, 6, 12, 14, 18, 19, 27, 30, 36, 44, 45, 46, 58
pgs. 5, 27, 30, 37
pgs. 5, 12
pgs. 9
pgs.44, 45
pgs. 23, 36
pgs. 2, 3, 10, 16, 45, 46
pgs. 15,19, 47
pgs. 1, 2, 60
pgs. 20
pgs. 15, 51, 52, 55
pgs. 23, 37
pgs. 1, 61
pgs. 23
CORPORATE HEADQUARTERS
2975 Stender Way
Santa Clara, CA 95054
for SALES:
800-345-7015 or 408-727-6116
fax: 408-492-8674
www.idt.com*
for Tech Support:
408-330-1552
email: [email protected]
*To search for sales office near you, please click the sales button found on our home page or dial the 800# above and press 2.
The IDT logo is a registered trademark of Integrated Device Technology, Inc.
61