NMXU Series - power, Murata

www.murata-ps.com
s
NOT RECOMMENDED
NMXU Series
NSS 5W Single & Dual Output DC/DC Converters
FOR NEW DESIGIsolated
SELECTION GUIDE
Order Code
FEATURES
„
RoHS compliant
„
Single or dual output
„
1kVDC isolation
„
Pin compatible with NMXSO series
„
Power density 0.85W/cm3
„
UL 94V-0 package material
„
Footprint 5.88cm2
V
V
A
%
Isolation
Capacitance
(Typ.)
pF
5
5
5
12
12
12
5
5
5
12
12
12
±5
±12
±15
±5
±12
±15
5
12
15
5
12
15
±0.5
±0.208
±0.167
±0.5
±0.208
±0.167
1.0
0.417
0.333
1.0
0.417
0.333
75
75
75
75
75
75
75
75
75
75
75
75
31.5
33
34.2
34.7
52.9
59.9
30.6
31.2
32.6
32.5
51.9
54.1
Nominal Input
Voltage
NMXD0505UC
NMXD0512UC
NMXD0515UC
NMXD1205UC
NMXD1212UC
NMXD1215UC
NMXS0505UC
NMXS0512UC
NMXS0515UC
NMXS1205UC
NMXS1212UC
NMXS1215UC
INPUT CHARACTERISTICS
„
5V & 12V input
Parameter
„
5V, 12V & 15V output
Voltage range
„
No heatsink required
Reflected ripple voltage
„
Fully encapsulated with toroidal magnetics
„
No external components required
„
PCB mounting
Output
Current
Efficiency
(Typ.)
MTTF1
Recommended
Alternative
kHrs
779
158
86
233
107
68
792
158
86
233
107
68
NCS6D1205C
NCS6D1212C
NCS6D1215C
NCS6S1205C
NCS6S1212C
NCS6S1215C
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external
capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the
additional external capacitance for reliable start up.
„
Industry standard pinout
„
Internal SMD construction
Output
Voltage
Conditions
Min.
Typ.
Max.
Continuous operation, 5V input types
Continuous operation, 12V input types
BW=DC to 20MHz, all output types
4.5
10.8
5.0
12.0
5.5
13.2
200
Units
mV
Max.
Units
5.0
W
V
OUTPUT CHARACTERISTICS
Parameter
Conditions
Rated Power
Voltage Set Point Accuracy
Line regulation
TA= 0°C to 70°C
See tolerance envelope
High VIN to low VIN
10% load to rated load, 5V output types
10% load to rated load, 12V & 15V output types
BW=DC to 20MHz, all output types
DESCRIPTION
Load Regulation
The NMXU series of DC/DC converters is particularly suited to isolating and/or converting DC
power rails. The galvanic isolation allows the
device to be configured to provide an isolated
negative rail in systems where only positive rails
exist. The devices are particularly suited for use
in distributed power systems where there is low
variation in the bus voltage levels.
Ripple and Noise
Min.
Typ.
1.1
7
5
%/%
12
7.5
125
%
mV p-p
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection2
Lead temperature 1.5mm from case for 10 seconds
Input voltage VIN, NMXU05 types
Input voltage VIN, NMXU12 types
1 second
300°C
7V
15V
1. Calculated using MIL-HDBK-217F with nominal input voltage at full load.
2. Supply voltage must be disconnected at the end of the short circuit duration.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NMXU.D01 Page 1 of 3
NMXU Series
Isolated 5W Single & Dual Output DC/DC Converters
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Isolation test voltage
Resistance
Flash tested for 1 second
Viso= 1000VDC
1000
1
Parameter
Conditions
Min.
Switching frequency
All input types
Typ.
Max.
Units
VDC
GΩ
GENERAL CHARACTERISTICS
Typ.
Max.
70
Units
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Specification
Storage
All output types
0
-55
Case temperature rise above
ambient
Cooling
5V output types
All other output types
Free air convection
Typ.
Max.
Units
70
100
30
20
TOLERANCE ENVELOPE
°C
RoHS COMPLIANCE INFORMATION
+10%
Output Voltage
+5%
VNOM
Typical
L
oad Line
+2.5%
This series is compatible with RoHS soldering
systems with a peak wave solder temperature of
300ºC for 10 seconds. The pin termination finish
on this product series is Matte Tin over Nickel
Preplate. The series is backward compatible with
Sn/Pb soldering systems.
-2.5%
-7.5%
10
75
50
25
Output Load Current (%)
100
For further information, please visit www.murata-ps.com/rohs
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NMXU series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specific agency approvals, such as the NMXU series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NMXU series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire.
While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel
(typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited.
We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
www.murata-ps.com/support
KDC_NMXU.D01 Page 2 of 3
NMXU Series
Isolated 5W Single & Dual Output DC/DC Converters
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS
0.985 (25.03)
Single Output Variants
Pin
Function
0.925
(23.50)
1
2
3
4
5
NMXD0515UC
XYYWW
0.394
(10.00)
-VIN
+VIN
+VOUT
Not fitted
-VOUT
Dual Output Variants
Pin
Function
1
2
3
4
5
VIN
+VIN
+VOUT
Common
-VOUT
RECOMMENDED FOOTPRINT DETAILS
0.035±0.00197
(0.90±0.05)
0.157 (4.0)
)0-&4
0.2 (5.08)
1
 2
0.80
(20.32)
5
4
3
*
0.063 (1.59)
0.093 (2.35)
0.0098±0
(0.25±0.
0.4 (10.16)
0.4 (10.16)
Weight: 10g
* Pin not fitted on single output variants.
All dimensions in inches ±0.01 (mm ±0.25mm). All pins on a 0.1 (2.54) pitch and within ±0.01 (0.25) of true position.
* Hole not required for single output variants
All dimensions in inches ±0.01 (mm ±0.25mm).
TUBE OUTLINE DIMENSIONS
Not to scale.
All dimensions in inches ±0.01 (mm ±0.25mm).
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2013 Murata Power Solutions, Inc.
www.murata-ps.com/support
KDC_NMXU.D01 Page 3 of 3