LITTELFUSE P0300SAMC

MicroCapacitance (MC) SA SIDACtor Device
MicroCapacitance (MC) SA SIDACtor Device
The DO-214AA SA MC SIDACtor series is intended for applications sensitive to load
values. Typically, high speed connections require a lower capacitance. CO values for the
MicroCapacitance device are 40% lower than a standard SA part.
This MC SIDACtor series is used to enable equipment to meet various regulatory
requirements including GR 1089, ITU K.20, K.21, and K.45, IEC 60950, UL 60950, and
TIA-968-A (formerly known as FCC Part 68).
Electrical Parameters
Part
Number *
VDRM
Volts
VS
Volts
VT
Volts
IDRM
µAmps
IS
mAmps
IT
Amps
IH
mAmps
CO
pF
P0080SA MC
6
25
4
5
800
2.2
50
45
P0300SA MC
25
40
4
5
800
2.2
50
25
* For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
• Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias.
Surge Ratings
Series
IPP
2x10 µs
Amps
IPP
8x20 µs
Amps
IPP
10x160 µs
Amps
IPP
10x560 µs
Amps
IPP
10x1000 µs
Amps
ITSM
60 Hz
Amps
di/dt
Amps/µs
A
150
150
90
50
45
20
500
http://www.littelfuse.com
+1 972-580-7777
2-8
© 2004 Littelfuse, Inc.
SIDACtor® Data Book and Design Guide
MicroCapacitance (MC) SA SIDACtor Device
Thermal Considerations
Symbol
TJ
Operating Junction Temperature Range
Parameter
-40 to +150
Value
°C
TS
Storage Temperature Range
-65 to +150
°C
90
°C/W
Thermal Resistance: Junction to Ambient
RθJA
Unit
IPP – Peak Pulse Current – %IPP
+I
+I
IITT
ISS
IH
IDRM
-V
-V
+V
+V
V
VTT
V
VDRM
DRM
V
VS
S
Peak
Value
100
tr = rise time to peak value
td = decay time to half value
Waveform = tr x td
50
Half Value
0
0
tr
td
t – Time (µs)
-I
-I
V-I Characteristics
tr x td Pulse Wave-form
IH
8
6
25 ˚C
4
2
IH (TC = 25 ˚C)
10
Ratio of
Percent of VS Change – %
14
12
0
-4
2.0
1.8
1.6
1.4
25 ˚C
1.2
1.0
0.8
0.6
0.4
-40 -20 0
-6
-8
-40 -20
0
20 40 60 80 100 120 140 160
Case Temperature (TC) – ˚C
20 40 60 80 100 120 140 160
Junction Temperature (TJ) – ˚C
Normalized VS Change versus Junction Temperature
© 2004 Littelfuse, Inc.
SIDACtor® Data Book and Design Guide
Normalized DC Holding Current versus Case Temperature
2-9
http://www.littelfuse.com
+1 972-580-7777
Data Sheets
Package
DO-214AA