ETC D205I

D200I Series
High Isolation
Miniature, 2W SIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
Parameter
● 2W Output Power
● 3,000 VDC Isolation
Input Voltage Range
● Miniature SIP Case
● Single & Dual Outputs
Input Filter
● >2 MHour MTBF
Reverse Polarity Input Current
Output
● 28 Standard Models
● Industry Standard Pin-Out Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation (Note 1)
Ripple & Noise (20 MHz) (Note 2)
Output Power Protection
Temperature Coefficient
Output Short Circuit
Conditions
Typ.
Max.
Units
5 VDC Input
4.5
5.0
12 VDC Input 10.8
12.0
24 VDC Input 21.6
24.0
48 VDC Input 42.0
48.0
Internal Capacitor
Min.
5.5
13.2
26.4
52.0
VDC
0.3
A
Typ.
Max.
Units
±1.0
±3.0
±1.0
%
%
%
75
±0.02
mV P - P
%
%/ºC
Max.
Units
Conditions
Min.
Dual Output , Balanced Loads
For Vin Change of 1%
±1.2
See Model Selection Guide
120
Momentary (0.5 Sec.)
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Min.
60 Seconds
500 VDC
100 kHz, 1V
Typ.
3,000
1,000
VDC
MΩ
pF
kHz
60
125
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Ambient
Case
Min.
Typ.
Max.
Units
-40
+25
+85
+100
+125
ºC
ºC
ºC
95
%
-40
Free Air Convection
RH, Non-condensing
Physical
MicroPower Direct
232 Tosca Drive
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Case Size (5V, 12V & 24V Input Models)
Case Size (48V Input Models)
Case Material
Weight
0.76 x 0.24 x 0.37 Inches (19.5 x 6.0 x 9.5 mm)
0.76 x 0.28 x 0.37 Inches (19.5 x 7.2 x 9.5 mm)
Non-Conductive Black Plastic (UL94-V0)
0.09 Oz (2.7g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
Typ.
Max.
2.0
Units
MHours
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
9.0
18.0
30.0
55.0
260
650
Units
VDC
ºC
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
D201I
D202I
D203I
D204I
D205I
D206I
D207I
D211I
D212I
D213I
D214I
D215I
D216I
D217I
D221I
D222I
D223I
D224I
D225I
D226I
D227I
D231I
D232I
D233I
D234I
D235I
D236I
D237I
Input
Output
Load
Fuse Rating
Efficiency
Voltage (VDC)
Current (mA)
Slow-Blow
Voltage Current
Current Regulation
(%, Typ)
(%, Max)
(mA)
Nominal
Range
Full-Load No-Load (VDC) (mA, Max) (mA, Min)
5
4.5 - 5.5
533
35
3.3
400.0
10.0
12
75
1,000
5
4.5 - 5.5
513
35
5.0
400.0
8.0
12
78
1,000
5
4.5 - 5.5
495
35
12.0
165.0
3.0
8
80
1,000
5
4.5 - 5.5
499
35
15.0
133.0
2.5
8
80
1,000
5
4.5 - 5.5
533
35
±5.0
±200.0
±4.0
12
75
1,000
5
4.5 - 5.5
504
35
±12.0
±83.0
±1.5
8
79
1,000
5
4.5 - 5.5
501
35
±15.0
±66.0
±1.0
8
79
1,000
12
10.8 - 13.2
204
25
3.3
400.0
10.0
8
67
500
12
10.8 - 13.2
212
25
5.0
400.0
8.0
8
78
500
12
10.8 - 13.2
196
25
12.0
165.0
3.0
8
85
500
12
10.8 - 13.2
200
25
15.0
133.0
2.5
8
83
500
12
10.8 - 13.2
216
25
±5.0
±200.0
±4.0
8
77
500
12
10.8 - 13.2
201
25
±12.0
±83.0
±1.5
8
82
500
12
10.8 - 13.2
200
25
±15.0
±66.0
±1.0
8
82
500
24
21.6 - 26.4
92
10
3.3
400.0
10.0
8
74
200
24
21.6 - 26.4
108
10
5.0
400.0
8.0
8
77
200
24
21.6 - 26.4
101
10
12.0
165.0
3.0
8
81
200
24
21.6 - 26.4
101
10
15.0
133.0
2.5
8
82
200
24
21.6 - 26.4
108
10
±5.0
±200.0
±4.0
8
77
200
24
21.6 - 26.4
102
10
±12.0
±83.0
±1.5
8
81
200
24
21.6 - 26.4
99
10
±15.0
±66.0
±1.0
8
84
200
48
42.0 - 52.0
59
10
3.3
400.0
10.0
8
70
100
48
42.0 - 52.0
54
10
5.0
400.0
8.0
8
77
100
48
42.0 - 52.0
51
10
12.0
165.0
3.0
8
81
100
48
42.0 - 52.0
50
10
15.0
133.0
2.5
8
82
100
48
42.0 - 52.0
54
10
±5.0
±200.0
±4.0
8
76
100
48
42.0 - 52.0
51
10
±12.0
±83.0
±1.5
8
81
100
48
42.0 - 52.0
50
10
±15.0
±66.0
±1.0
8
82
100
Notes:
1. Output load regulation is specified for a load change of 20% to 100%.
2. When measuring output ripple, it is recommended that an external ceramic capacitor (approx 10 µF)
be placed from the +Vout pin to the -Vout pin for single output units and from each output to common
for dual output units.
3. All 3.3, 5 and ±5 VDC output models may be operated to +85ºC ambient with an unobstructed airflow
of 3.6 ft/S (1.1 m/S).
4. The 5V, 12V and 24V input units do not require external components to operate, but the use of an
input capacitor (10 µF) may enhance performance in some applications. An output capacitor (1.0 µF
to 10 µF) may be used to reduce ripple. The 48V input models require an input capacitor of 4.7 uF to
47 uF (dependent upon the application).
5. Dual output units may be connected to provide a 10V, 24V or 30 VDC output. To do this, connect the
load across the positive (+Vout) and negative (-Vout) outputs and float the output common.
6. It is recommended that a fuse be used on the input of a power supply for protection. See the table above
for the correct rating.
Derating Curve
Pin Connections
Pin
Single
Dual
1
2
5
6
7
+Vin
-Vin
-Vout
No Pin
+Vout
+Vin
-Vin
-Vout
Common
+Vout
Mechanical Dimensions
Capacitive
Load
Single Output
(μF Max)
470
Dual Output
(μF Max)
±390
Notes: All dimensions are typical in inches (mm)
Tolerance x.xx = ±0.01 (±0.25)
Pin 1 is marked by a “dot” or indentation on the side of the unit
MicroPower Direct
www.micropowerdirect.com
232 Tosca Drive Stoughton, MA 02072
■
TEL: (781) 344-8226
■
FAX: (781) 344-8481
■
E-Mail: [email protected]