MPD E100

E100 Series
Isolated, Single Output
Miniature, 1W SIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 1W Output Power
• Miniature SIP Case
• 1,000 VDC Isolation
• Complies to RFI Standards
• >2 MHour MTBF
• 20 Standard Models
• Industry Standard Pin-Out
RoHS Compliant
Parameter
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
Input Voltage Range
Reverse Polarity Input Current
Input Filter
Min.
4.5
10.8
21.6
43.2
Typ.
5.0
12.0
24.0
48.0
Max.
5.5
13.2
26.4
52.8
0.3
Units
Max.
±3.0
Units
%
%
VDC
A
Internal Capacitor
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation (Note 1)
Ripple & Noise (20 MHz) (Note 2)
Output Power Protection
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Typ.
For Vin Change of 1%
±1.2
See Model Selection Guide
60
110
±0.01
Momentary (0.5 Sec.)
±0.02
mV P - P
%
%/ºC
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI/RFI
Conditions
Units
VDC
MΩ
60
pF
50
kHz
EN55022 A, EN55024 A, IEC 61000-4-2, IEC 61000-4-3, FCC 47 CFR Part 15 B
60 Seconds
1,000 VDC
100 kHz, 1V
Min.
1,000
1,000
Typ.
Max.
Min.
-40
Typ.
+25
Max.
+85
+100
+125
Units
ºC
ºC
ºC
95
%
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
MicroPower Direct
292 Page Street
Ste D
Stoughton, MA 02072
USA
Conditions
Ambient
Case
-40
Free Air Convection
RH, Non-condensing
Physical
Case Size (5V, 12V & 24V Input Models)
Case Size (48V Input Models)
Case Material
Weight
0.46 x 0.24 x 0.40 Inches (11.68 x 6.0 x 10.2 mm)
0.46 x 0.29 x 0.40 Inches (11.68 x 7.5 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
0.06 Oz (1.8g)
Reliability Specifications
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
2.0
Typ.
Max.
Units
MHours
Conditions
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
7.0
15.0
28.0
54.0
260
650
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
All Models
VDC
ºC
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Load
Input
Output
Voltage Current
Current Regulation
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load (VDC) (mA, Max) (mA, Min) (% Max)
5
4.5 - 5.5
267
25
5.0
200.0
4.0
10
5
4.5 - 5.5
260
25
9.0
111.0
2.0
10
5
4.5 - 5.5
256
25
12.0
83.3
2.0
10
5
4.5 - 5.5
257
25
15.0
66.6
2.0
10
5
4.5 - 5.5
257
25
24.0
41.6
2.0
10
12
10.8 - 13.2
112
16
5.0
200.0
4.0
10
12
10.8 - 13.2
109
16
9.0
111.0
2.0
10
12
10.8 - 13.2
107
16
12.0
83.3
2.0
10
12
10.8 - 13.2
107
16
15.0
66.6
2.0
10
12
10.8 - 13.2
107
16
24.0
41.6
2.0
10
24
21.6 - 26.4
56
10
5.0
200.0
4.0
10
24
21.6 - 26.4
55
10
9.0
111.0
2.0
10
24
21.6 - 26.4
54
10
12.0
83.3
2.0
10
24
21.6 - 26.4
54
10
15.0
66.6
2.0
10
24
21.6 - 26.4
54
10
24.0
41.6
2.0
10
48
43.2 - 52.8
28
7
5.0
200.0
4.0
10
48
43.2 - 52.8
27
7
9.0
111.0
2.0
10
48
43.2 - 52.8
27
7
12.0
83.3
2.0
10
48
43.2 - 52.8
27
7
15.0
66.6
2.0
10
48
43.2 - 52.8
27
7
24.0
41.6
2.0
10
Model
Number
E101
E102
E103
E104
E105
E111
E112
E113
E114
E115
E121
E122
E123
E124
E125
E131
E132
E133
E134
E135
Models with other outputs
are available. Contact the
factory for details!!
Efficiency
(%, Typ)
75
77
78
78
78
75
77
78
78
78
75
77
78
78
78
75
76
76
76
76
Fuse Rating
Slow-Blow
(mA)
500
500
500
500
500
200
200
200
200
200
100
100
100
100
100
50
50
50
50
50
Derating Curve
Notes:
1. Output load regulation is specified for a load change of
20% to 100%.
2. When measuring output ripple, it is recommended that
an external 0.33 µF ceramic capacitor be placed from the
+Vout pin to the -Vout pin.
3. Operation at no-load will not damage these units. However, they may not meet all specifications.
4. The 5V, 12V and 24V input units do not require external
components to operate, but the use of a low ESR capacitor (approximately 10 uF, ESR <1.0Ω at 100 kHz) mounted
close to the converter input pins is recommended.
For 48 VDC input units, an input capacitor should always
be used. Dependent upon the application, a value between 4.7 µF and 47 uF should be sufficient.
5. It is recommended that a fuse be used on the input of
a power supply for protection. See the table above for
the correct rating.
Pin Connections
Capacitive
Load
(µF Max)
220
Pin
Description
1
-Vin
2
+Vin
3
-Vout
4
+Vout
Mechanical Dimensions
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the side of the
unit
• Dimensions indicated on the drawing are as follows:
Dimension
Input Voltage
5, 12 & 24V
48V
“W”
0.24 (6.0)
0.29 (7.5)
“X”
0.05 (1.25)
0.08 (2.00)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]