VISHAY UGF18CCT

NEW PRODUCT
NEW PRODUCT
NEW PRODUCT
UGF18ACT THRU UGF18DCT
ULTRAFAST EFFICIENT PLASTIC RECTIFIER
Reverse Voltage - 50 to 200 Volts
FEATURES
ITO-220AB
0.188 (4.77)
0.172 (4.36)
0.405 (10.27)
0.383 (9.72)
0.110 (2.80)
0.100 (2.54)
0.131 (3.39)
DIA.
0.122 (3.08)
0.140 (3.56)
DIA.
0.130 (3.30)
0.600 (15.5)
0.580 (14.5)
0.670 (17.2)
0.646 (16.4)
PIN
1
2
3
0.350 (8.89)
0.330 (8.38)
0.191 (4.85)
0.171 (4.35)
0.560 (14.22)
0.530 (13.46)
Forward Current - 18.0 Amperes
♦ Plastic package has Underwriters Laboratories
Flammability Classification 94V-0
♦ Ideally suited for use in very
high frequency switching
power supplies, inverters
and as a free wheeling diode
♦ Ultrafast 25 nanosecond reverse recovery times
♦ Soft recovery characteristics
♦ Excellent high temperature switching
♦ Glass passivated junctions
♦ High temperature soldering guaranteed:
250°C, 0.25" (6.35mm) from case for 10 seconds
0.110 (2.80)
0.100 (2.54)
0.060 (1.52)
MECHANICAL DATA
0.037 (0.94)
0.027 (0.69)
0.205 (5.20)
0.195 (4.95)
0.105 (2.67)
0.095 (2.41)
0.022 (0.55)
0.014 (0.36)
PIN 1
PIN 2
PIN 3
Dimensions in inches and (millimeters)
Case: JEDECITO-220AB molded plastic body
Terminals: Plated leads solderable per MIL-STD-750,
Method 2026
Polarity: As marked
Mounting Position: Any
Weight: 0.08 ounce, 2.24 grams
Mounting Torque: 5 in. - lbs. max.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
Maximum repetitive peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
Maximum average forward rectified current at TC=105°C
Peak forward surge current
8.3ms single half sine-wave superimposed
on rated load (JEDEC Method) per leg at TC=105°C
Maximum instantaneous forward voltage per leg at 9.0A
20A
5.0A, TJ=100°C
Maximum DC reverse current
TA=25°C
at rated DC blocking voltage per leg
TA=100°C
Maximum reverse recovery time (NOTE 1)
Maximum reverse recovery time
TJ=25°C
TJ=100°C
(NOTE 2)
Maximum recovered stored charge
TJ=25°C
TJ=100°C
(NOTE 2)
Typical junction capacitance (NOTE 3)
Typical thermal resistance (NOTE 4)
Operating junction and storage temperature range
NOTES: (1) Reverse recovery test conditions: IF=0.5A, IR=1.0A, Irr=0.25A
(2) trr and Qrr measured at: IF=9.0A, VR=30V, di/dt=50A/µs, Irr=10% IRM
(3) Measured at 1.0 MHZ and applied reverse voltage of 4.0 Volts
(4) Thermal resistance from junction to case per leg
4/98
SYMBOLS
UGF18ACT
UGF18BCT
UGF18CCT
UGF18DCT
UNITS
VRRM
VRMS
VDC
50
35
50
100
70
100
150
105
150
200
140
200
Volts
Volts
Volts
I(AV)
18.0
IFSM
175.0
VF
IR
trr
trr
Qrr
1.10
1.20
0.95
10.0
300.0
20.0
30.0
50.0
20.0
45.0
Amps
Amps
Volts
µA
ns
ns
nC
CJ
RΘJC
30.0
4.0
pF
°C/W
TJ, TSTG
-65 to +150
°C
RATINGS AND CHARACTERISTIC CURVES UGF18ACT THRU UGF18DCT
FIG. 2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT PER LEG
FIG. 1 -FORWARD CURRENT DERATING CURVE
1,000
RESISTIVE OR INDUCTIVE LOAD
20
16
12
8.0
4.0
0
0
25
50
75
100 125 150 175
PEAK FORWARD SURGE CURRENT,
AMPERES
AVERAGE FORWARD CURRENT,
AMPERES
24
8.3ms SINGLE HALF SINE-WAVE
(JEDEC Method)
TC=105°C
100
10
CASE TEMPERATURE, °C
100
10
1
NUMBER OF CYCLES AT 60 HZ
100
TJ=25°C
PULSE WIDTH=300µs
1% DUTY CYCLE
10
1
0.1
0.01
0.4
0.6
0.8
1.0
1.2
1.4
1.6
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
FIG. 5 - REVERSE SWITCHING CHARACTERISTICS
PER LEG
TJ=125°C
100
TJ=100°C
10
1
TJ=25°C
0.1
0.01
0
20
40
60
80
100
PERCENT OF RATED PEAK REVERSE
VOLTAGE, %
FIG. 6 - TYPICAL JUNCTION CAPACITANCE PER LEG
di/dt=100A/µs
IF=9.0A
VR=30V
50
di/dt=20A/µs
40
di/dt=50A/µs
di/dt=100A/µs
di/dt=50A/µs
di/dt=150A/µs
30
20
di/dt=20A/µs
10
trr
Qrr
0
25
50
75
100 125 150 175
JUNCTION TEMPERATURE, °C
JUNCTION CAPACITANCE, pF
STORED CHARGE/REVERSE
RECOVERY TIME, nC/ns
1,000
100
60
0
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
PER LEG
INSTANTANEOUS REVERSE LEAKAGE CURRENT,
MICROAMPERES
INSTANTANEOUS FORWARD CURRENT,
AMPERES
FIG. 3 - TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER LEG
TJ=125°C
f=1.0 MHz
Vsig=50MVp-p
10
1
0.1
1
10
REVERSE VOLTAGE, VOLTS
100