GI850 thru GI858 Vishay General Semiconductor Fast Switching Plastic Rectifier FEATURES • Fast switching for high efficiency • Low forward voltage drop • Low leakage current • High forward surge capability • Solder dip 275 °C max. 10 s, per JESD 22-B106 • Compliant to RoHS directive 2002/95/EC and in accordance to WEEE 2002/96/EC DO-201AD TYPICAL APPLICATIONS For use in fast switching rectification of power supply, inverters, converters and freewheeling diodes for consumer and telecommunication. PRIMARY CHARACTERISTICS Note • These devices are not AEC-Q101 qualified. IF(AV) 3.0 A VRRM 50 V to 800 V IFSM 100 A MECHANICAL DATA trr 200 ns IR 10 μA VF 1.25 V Case: DO-201AD, molded epoxy body Molding compound meets UL 94 V-0 flammability rating Base P/N-E3 - RoHS compliant, commercial grade TJ max. 150 °C Terminals: Matte tin plated leads, solderable J-STD-002 and JESD 22-B102 E3 suffix meets JESD 201 class 1A whisker test per Polarity: Color band denotes cathode end MAXIMUM RATINGS (TA = 25 °C unless otherwise noted) PARAMETER SYMBOL GI850 GI851 GI852 GI854 GI856 GI858 UNIT Maximum repetitive peak reverse voltage VRRM 50 100 200 400 600 800 V Maximum RMS voltage VRMS 35 70 140 280 420 560 V Maximum DC blocking voltage VDC 50 100 200 400 600 800 V Maximum non-repetitive peak reverse voltage VRSM 75 150 250 450 650 880 V Maximum average forward rectified current 0.375" (9.5 mm) lead length at TA = 90 °C IF(AV) 3.0 A Peak forward surge current 8.3 ms single half sine-wave superimposed on rated load IFSM 100 A TJ, TSTG - 50 to + 150 °C Operating junction and storage temperature range Document Number: 88630 Revision: 10-Nov-09 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] www.vishay.com 1 GI850 thru GI858 Vishay General Semiconductor ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER TEST CONDITIONS Maximum instantaneous forward voltage 3.0 A SYMBOL GI850 GI851 GI852 TA = 25 °C GI854 GI856 GI858 1.25 VF V TJ = 175 °C 9.4 A Maximum DC reverse current at rated DC blocking voltage UNIT 1.10 TA = 25 °C 10 IR TA = 100 °C μA 150 150 200 250 300 500 Maximum reverse recovery current IF = 1.0 A, VR = 30 V, dI/dt = 50 A/μs, Irr = 10 % IRM IRM(REC) 200 ns Maximum reverse recovery time IF = 1.0 A, VR = 30 V, dI/dt = 50 A/μs, Irr = 10 % IRM trr 2.0 A Typical junction capacitance 4.0 V, 1 MHz CJ 28 pF THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER SYMBOL Typical thermal resistance GI850 GI851 GI852 GI854 RθJA (1) 22 RθJL (1) 8.0 GI856 GI858 UNIT °C/W Note (1) Thermal resistance from junction to ambient and from junction to lead at 0.375" (9.5 mm) lead length, with both leads equally heat sink ORDERING INFORMATION (Example) PREFERRED P/N UNIT WEIGHT (g) PREFERRED PACKAGE CODE BASE QUANTITY DELIVERY MODE GI856-E3/54 1.1 54 1400 13" diameter paper tape and reel GI856-E3/73 1.1 73 1000 Ammo pack packaging RATINGS AND CHARACTERISTICS CURVES (TA = 25 °C unless otherwise noted) 1000 8.3 ms Single Half Sine-Wave L = Lead Length TL = Lead Temperature L= 0.2 5" ( 6.3 mm L= ) 0.3 75 " (9 .5 mm ) 6.0 4.0 2.0 0.8" x 0.8" x 0.04" (20 mm x 20 mm x 1 mm) Copper Heatsink TA = Ambient Temperature 0.375" (9.5 mm) Lead Length 0 Peak Forward Surge Current (A) Average Forward Rectified Current (A) 8.0 TJ = 25 °C 100 Non-Repetitive TJ = 150 °C TJ = 25 °C Repetitive TJ = 150 °C 10 30 50 70 90 110 130 150 170 1 100 10 Temperature (°C) Number of Cycles at 60 Hz Fig. 1 - Forward Current Derating Curves Fig. 2 - Maximum Peak Forward Surge Current www.vishay.com 2 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] Document Number: 88630 Revision: 10-Nov-09 GI850 thru GI858 Vishay General Semiconductor 100 10 TJ = 25 °C Pulse Width = 300 μs 1 % Duty Cycle 1 0.1 0.01 0.4 TJ = 25 °C f = 1.0 MHz Vsig = 50 mVp-p Junction Capacitance (pF) Instantaneous Forward Current (A) 100 10 0.6 0.8 1.0 1.2 1.4 1.6 1 1.8 10 100 Instantaneous Forward Voltage (V) Reverse Voltage (V) Fig. 3 - Typical Instantaneous Forward Characteristics Fig. 5 - Typical Junction Capacitance Instantaneous Reverse Current (μA) 10 TJ = 100 °C 1 TJ = 50 °C 0.1 TJ = 25 °C 0.01 0 20 40 60 80 100 Percent of Rated Peak Reverse Voltage (%) Fig. 4 - Typical Reverse Characteristics PACKAGE OUTLINE DIMENSIONS in inches (millimeters) DO-201AD 1.0 (25.4) MIN. 0.210 (5.3) 0.190 (4.8) DIA. 0.375 (9.5) 0.285 (7.2) 1.0 (25.4) MIN. 0.052 (1.32) 0.048 (1.22) DIA. Document Number: 88630 Revision: 10-Nov-09 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] www.vishay.com 3 Legal Disclaimer Notice Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Document Number: 91000 Revision: 11-Mar-11 www.vishay.com 1