VISHAY GI854

GI850 thru GI858
Vishay General Semiconductor
Fast Switching Plastic Rectifier
FEATURES
• Fast switching for high efficiency
• Low forward voltage drop
• Low leakage current
• High forward surge capability
• Solder dip 275 °C max. 10 s, per JESD 22-B106
• Compliant to RoHS directive 2002/95/EC and in
accordance to WEEE 2002/96/EC
DO-201AD
TYPICAL APPLICATIONS
For use in fast switching rectification of power supply,
inverters, converters and freewheeling diodes for consumer
and telecommunication.
PRIMARY CHARACTERISTICS
Note
• These devices are not AEC-Q101 qualified.
IF(AV)
3.0 A
VRRM
50 V to 800 V
IFSM
100 A
MECHANICAL DATA
trr
200 ns
IR
10 μA
VF
1.25 V
Case: DO-201AD, molded epoxy body
Molding compound meets UL 94 V-0 flammability rating
Base P/N-E3 - RoHS compliant, commercial grade
TJ max.
150 °C
Terminals: Matte tin plated leads, solderable
J-STD-002 and JESD 22-B102
E3 suffix meets JESD 201 class 1A whisker test
per
Polarity: Color band denotes cathode end
MAXIMUM RATINGS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
GI850
GI851
GI852
GI854
GI856
GI858
UNIT
Maximum repetitive peak reverse voltage
VRRM
50
100
200
400
600
800
V
Maximum RMS voltage
VRMS
35
70
140
280
420
560
V
Maximum DC blocking voltage
VDC
50
100
200
400
600
800
V
Maximum non-repetitive peak reverse voltage
VRSM
75
150
250
450
650
880
V
Maximum average forward rectified current
0.375" (9.5 mm) lead length at TA = 90 °C
IF(AV)
3.0
A
Peak forward surge current 8.3 ms single half
sine-wave superimposed on rated load
IFSM
100
A
TJ, TSTG
- 50 to + 150
°C
Operating junction and
storage temperature range
Document Number: 88630
Revision: 10-Nov-09
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
www.vishay.com
1
GI850 thru GI858
Vishay General Semiconductor
ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
TEST CONDITIONS
Maximum
instantaneous
forward voltage
3.0 A
SYMBOL
GI850
GI851
GI852
TA = 25 °C
GI854
GI856
GI858
1.25
VF
V
TJ = 175 °C
9.4 A
Maximum DC reverse
current at rated DC
blocking voltage
UNIT
1.10
TA = 25 °C
10
IR
TA = 100 °C
μA
150
150
200
250
300
500
Maximum reverse
recovery current
IF = 1.0 A, VR = 30 V,
dI/dt = 50 A/μs, Irr = 10 % IRM
IRM(REC)
200
ns
Maximum reverse
recovery time
IF = 1.0 A, VR = 30 V,
dI/dt = 50 A/μs, Irr = 10 % IRM
trr
2.0
A
Typical junction
capacitance
4.0 V, 1 MHz
CJ
28
pF
THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
Typical thermal resistance
GI850
GI851
GI852
GI854
RθJA (1)
22
RθJL (1)
8.0
GI856
GI858
UNIT
°C/W
Note
(1) Thermal resistance from junction to ambient and from junction to lead at 0.375" (9.5 mm) lead length, with both leads equally heat sink
ORDERING INFORMATION (Example)
PREFERRED P/N
UNIT WEIGHT (g)
PREFERRED PACKAGE CODE
BASE QUANTITY
DELIVERY MODE
GI856-E3/54
1.1
54
1400
13" diameter paper tape and reel
GI856-E3/73
1.1
73
1000
Ammo pack packaging
RATINGS AND CHARACTERISTICS CURVES
(TA = 25 °C unless otherwise noted)
1000
8.3 ms Single Half Sine-Wave
L = Lead Length
TL = Lead Temperature
L=
0.2
5" (
6.3
mm
L=
)
0.3
75
" (9
.5
mm
)
6.0
4.0
2.0
0.8" x 0.8" x 0.04"
(20 mm x 20 mm x 1 mm)
Copper Heatsink
TA = Ambient Temperature
0.375" (9.5 mm) Lead Length
0
Peak Forward Surge Current (A)
Average Forward Rectified Current (A)
8.0
TJ = 25 °C
100
Non-Repetitive
TJ = 150 °C
TJ = 25 °C
Repetitive
TJ = 150 °C
10
30
50
70
90
110
130
150
170
1
100
10
Temperature (°C)
Number of Cycles at 60 Hz
Fig. 1 - Forward Current Derating Curves
Fig. 2 - Maximum Peak Forward Surge Current
www.vishay.com
2
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
Document Number: 88630
Revision: 10-Nov-09
GI850 thru GI858
Vishay General Semiconductor
100
10
TJ = 25 °C
Pulse Width = 300 μs
1 % Duty Cycle
1
0.1
0.01
0.4
TJ = 25 °C
f = 1.0 MHz
Vsig = 50 mVp-p
Junction Capacitance (pF)
Instantaneous Forward Current (A)
100
10
0.6
0.8
1.0
1.2
1.4
1.6
1
1.8
10
100
Instantaneous Forward Voltage (V)
Reverse Voltage (V)
Fig. 3 - Typical Instantaneous Forward Characteristics
Fig. 5 - Typical Junction Capacitance
Instantaneous Reverse Current (μA)
10
TJ = 100 °C
1
TJ = 50 °C
0.1
TJ = 25 °C
0.01
0
20
40
60
80
100
Percent of Rated Peak Reverse Voltage (%)
Fig. 4 - Typical Reverse Characteristics
PACKAGE OUTLINE DIMENSIONS in inches (millimeters)
DO-201AD
1.0 (25.4)
MIN.
0.210 (5.3)
0.190 (4.8)
DIA.
0.375 (9.5)
0.285 (7.2)
1.0 (25.4)
MIN.
0.052 (1.32)
0.048 (1.22)
DIA.
Document Number: 88630
Revision: 10-Nov-09
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
www.vishay.com
3
Legal Disclaimer Notice
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 11-Mar-11
www.vishay.com
1