TLP3902 TOSHIBA PHOTOCOUPLER GaAs IRED & PHOTO−DIODE ARRAY TLP3902 SOLID STATE RELAY PROGRAMMABLE CONTROLLERS MOS FET GATE DRIVER Unit in mm The TOSHIBA mini flat coupler TLP3902 is a small outline coupler, suitable for surface mount assembly. The TLP3902 consists of a GaAs light emitting diode, optically coupled to a series connected photo diode array which is suitable for MOS FET gate drive. Features • Open Voltage : 7V (min) • Short Current : 5μA (min) • Isolation Voltage : 2500Vrms (min) Pin Configuration (top view) TOSHIBA 11-4C1 Weight: 0.09 g 1 6 1. ANODE 3. CATHODE 4. CATHODE 6. ANODE 3 4 1 2007-10-01 TLP3902 Absolute Maximum Ratings (Ta = 25°C) Characteristic Symbol Rating Unit IF 50 mA ΔIF / °C −0.5 mA / °C Reverse Voltage VR 5 V Junction Temperature Tj 125 °C Forward Current IFD 50 μA DETECTOR Reverse Voltage VRD 10 V Tj 125 °C Storage Temperature Range Tstg −55~125 °C Operating Temperature Range Topr −40~85 °C Lead Soldering Temperature (10 s) Tsol 260 °C Isolation Voltage (AC, 1 min., R.H. ≤ 60%) BVS 2500 Vrms Forward Current LED Forward Current Derating (Ta ≥ 25°C) Junction Temperature (Note 1) Note: Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum ratings. Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook (“Handling Precautions”/“Derating Concept and Methods”) and individual reliability data (i.e. reliability test report and estimated failure rate, etc). Note 1: Device considered a two terminal device: Pins 1 and 3 shorted together and pins 4 and 6 shorted together. Recommended Operating Conditions (Note 2) Characteristic Symbol Min Typ. Max Unit IF 7 — 20 mA Topr −25 — 65 °C Forward Current Operating Temperature Note: Recommended operating conditions are given as a design guideline to obtain expected performance of the device. Additionally, each item is an independent guideline respectively. In developing designs using this product, please confirm specified characteristics shown in this document. Individual Electrical Characteristics (Ta = 25°C) Characteristic LED DETECTOR Symbol Test Condition Min Typ. Max Unit 1.10 1.15 1.3 V Forward Voltage VF IF = 10 mA Reverse Current IR VR = 5 V — — 10 μA Capacitance CT V = 0, f = 1 MHz — 30 — pF Forward Voltage VFD IFD = 10 μA — 9.6 — V Reverse Current IRD VRD = 10 V — 1 — nA Capacitance (Anode to Cathode) CTD V = 0, f = 1 MHz — 8 — pF 2 2007-10-01 TLP3902 Coupled Electrical Characteristics (Ta = 25°C) Characteristic Symbol Test Condition Min Typ. Max Unit Open-Circuit Voltage VOC IF = 10 mA 7 9.5 — V Short-Circuit Current ISC IF = 10 mA 5 10 — μA Min Typ. Max Unit — 0.8 — pF — Ω Isolation Characteristics (Ta = 25°C) Characteristic Symbol Capacitance Input to Output CS Isolation Resistance RS Test Condition VS = 0, f = 1 MHz VS = 500 V, R.H. ≤ 60% 5×10 AC, 1 minute Isolation Voltage BVS 10 10 14 2500 — — AC, 1 second in oil — 5000 — DC, 1 minute in oil — 5000 — Vdc Vrms Switching Characteristics (Ta = 25°C) Characteristic Symbol Test Condition Min Typ. Max Unit Turn−on Time tON — 0.6 — ms Turn−off Time tOFF IF = 10 mA, RSH = 1 MΩ (Note 3) CL = 1000pF — 2 — ms (Note 3) : SWITCHING TIME TEST CIRCUIT IF VOUT RSH IF CL VOUT 5V 1V 0V tON RSH : External Shunt Resistance 3 tOFF 2007-10-01 TLP3902 I F ─ Ta I F ─ VF 90 50 FORWARD CURRENT I F (mA) 100 ALLOWABLE FORWARD CURRENT I F (mA) 100 80 70 60 50 40 30 20 10 0 -20 0 20 40 60 80 AMBIENT TEMPERATURE 100 Ta = 25 °C 30 10 5 3 1 0.5 0.3 0.1 0.6 120 0.8 Ta (°C) 1 I o ─ Vo tON,tOFF (ms) IF =0 mA 0 SWITCHING TIME OUTPUT CURRENT I o (µA) 20 5 mA 10 mA 15 mA -20 20 mA 25 mA 0 2 4 6 OUTPUT VOLTAGE 8 Ta = 25 °C I F = 10 mA tON tOFF 30 10 1.8 RSH=2.2MΩ 1MΩ 510kΩ 3 510kΩ 1MΩ 1 2.2MΩ 0.3 0.1 0.03 0.01 10 Vo (V) 102 103 300 Voc ─ I F 104 3000 LOAD CAPACITANCE CL (pF) Isc ─ I F 14 100 13 Ta = 25 °C I s c (µA) Ta = 25 °C 12 11 10 RSH = OPEN 9 8 SHORT CURRENT Voc (V) 1.6 VF (V) 100 Ta = 25 °C OPEN VOLTAGE 1.4 tON,tOFF─ CL 40 -40 1.2 FORWARD VOLTAGE 2.2MΩ 7 1MΩ 6 510kΩ 5 4 3 2 50 30 10 5 3 1 0 1 3 5 10 1 30 FORWARD CURRENT I F (mA) 1 3 5 30 10 FORWARD CURRENT I F (mA) 4 2007-10-01 TLP3902 Voc ─ Ta Isc ─ Ta 20 14 I F = 10 mA 18 SHORT CURRENT I s c (µA) OPEN VOLTAGE Voc (V) 13 12 11 10 9 8 7 6 5 4 -20 0 20 40 60 AMBIENT TEMPERATURE 80 16 14 12 10 8 6 4 2 0 -20 100 Ta (°C) I F = 10 mA 0 20 40 60 AMBIENT TEMPERATURE 5 80 100 Ta (°C) 2007-10-01 TLP3902 RESTRICTIONS ON PRODUCT USE 20070701-EN • The information contained herein is subject to change without notice. • TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc. • The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.).These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in his document shall be made at the customer’s own risk. • The products described in this document shall not be used or embedded to any downstream products of which manufacture, use and/or sale are prohibited under any applicable laws and regulations. • The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patents or other rights of TOSHIBA or the third parties. • GaAs(Gallium Arsenide) is used in this product. The dust or vapor is harmful to the human body. Do not break, cut, crush or dissolve chemically. • Please contact your sales representative for product-by-product details in this document regarding RoHS compatibility. Please use these products in this document in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances. Toshiba assumes no liability for damage or losses occurring as a result of noncompliance with applicable laws and regulations. 6 2007-10-01