TLOU156P(F),TLSU156P(F),TLYU156P(F) TOSHIBA InGaAℓP LED TLOU156P(F),TLSU156P(F),TLYU156P(F) Panel Circuit Indicator Unit in mm • Lead(Pb)-free products (lead: Sn-Ag-Cu) • 5mm package • InGaAℓP LED • Without stand−offs • All plastic mold type • Colorless clear lens • Lineup: 3 colors (red, orange, yellow) • Suitable for high−brightness and less electricity consumption. • All plastic molded lens, provides an excellent on−off contrast ratio. • Applications: Backlight, light for decoration, switches, various indicator, personal equipment Lineup Product Color Material TLOU156P(F) Orange InGaAℓP TLSU156P(F) Red InGaAℓP TLYU156P(F) Yellow InGaAℓP JEDEC ― JEITA ― TOSHIBA 4-5AH2 Weight: 0.31 g(Typ.) Absolute Maximum Ratings (Ta = 25°C) Product Forward Current IF(mA) Reverse Voltage VR(V) Power Dissipation PD(mW) Operating Temperature Topr(°C) Storage Temperature Tstg(°C) TLOU156P(F) 30 4 72 −30~85 −40~120 TLSU156P(F) 30 4 72 −30~85 −40~120 TLYU156P(F) 30 4 75 −30~85 −40~120 Note: Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum ratings. Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook (“Handling Precautions”/“Derating Concept and Methods”) and individual reliability data (i.e. reliability test report and estimated failure rate, etc). 1 2007-10-01 TLOU156P(F),TLSU156P(F),TLYU156P(F) Electrical and Optical Characteristics (Ta = 25°C) Typ. Forward Voltage VF Max IF Reverse Current IR Max VR λp Δλ IF Min Luminous Intensity IV Typ. TLOU156P(F) (612) 15 20 476 1400 20 2.0 2.4 20 50 4 TLSU156P(F) (636) 17 20 272 900 20 2.0 2.4 20 50 4 TLYU156P(F) (590) 13 20 153 500 20 2.1 2.5 20 50 4 mA μA V Typ.Emission Wavelength Product Unit nm mA mcd IF mA V Precaution • Please be careful of the followings Soldering temperature: 260°C max Soldering time: 3 s max (Soldering portion of lead: Up to 1.6 mm from the body of the device) • If the lead is formed, the lead should be formed up to 1.6 mm from the body of the device without forming stress to the resin. Soldering should be performed after lead forming. • This visible LED lamp also emits some IR light. If a photodetector is located near the LED lamp, please ensure that it will not be affected by this IR light. 2 2007-10-01 TLOU156P(F),TLSU156P(F),TLYU156P(F) TLOU156P(F) IF – V F 100 IV – IF 2000 Ta = 25°C (mA) Luminous intensity IV (mcd) 50 Forward current IF 20 10 5 2 1 1.6 1.8 2.0 2.2 2.4 Forward voltage VF 1000 500 200 100 50 20 2.6 Ta = 25°C 1 2 (V) 10 20 Forward current IF 50 100 640 660 (mA) Relative Luminous Intensity – Wavelength IV – Tc 10 1.0 IF = 20mA Ta = 25°C Relative luminous intensity 5 Relative luminous intensity IV 5 2 1 0.5 0.8 0.6 0.4 0.2 0.2 0.1 −25 0 25 75 50 0 540 100 560 Case temperature Tc (°C) 600 580 Wavelength λ (nm) Radiation Pattern IF – Ta 40 20° 0° 10° 20° 30° 30° 40° 40° 50° 50° 60° 60° 70° 70° 80° 80° 90° Allowable forward current IF (mA) Ta = 25°C 10° 0 0.2 620 0.4 0.6 0.8 90° 1.0 30 20 10 0 0 20 40 60 80 100 Ambient temperature Ta (°C) 3 2007-10-01 TLOU156P(F),TLSU156P(F),TLYU156P(F) TLSU156P(F) IF – V F 100 IV – IF 2000 Ta = 25°C (mA) Luminous intensity IV (mcd) 50 Forward current IF 20 10 5 2 1 1.6 1.8 2.0 2.2 2.4 Forward voltage VF 1000 500 200 100 50 20 2.6 Ta = 25°C 1 2 5 (V) 10 20 Forward current IF 50 100 660 680 (mA) Relative Luminous Intensity – Wavelength IV – Tc 10 1.0 IF = 20mA Ta = 25°C Relative luminous intensity Relative luminous intensity IV 5 2 1 0.5 0.8 0.6 0.4 0.2 0.2 0.1 −25 0 25 75 50 0 560 100 580 Case temperature Tc (°C) 620 600 Wavelength λ (nm) Radiation Pattern IF – Ta 40 20° 10° 10° 20° 30° 30° 40° 40° 50° 50° 60° 60° 70° 70° 80° 80° 90° Allowable forward current IF (mA) Ta = 25°C 0° 0 0.2 640 0.4 0.6 0.8 90° 1.0 30 20 10 0 0 20 40 60 80 100 Ambient temperature Ta (°C) 4 2007-10-01 TLOU156P(F),TLSU156P(F),TLYU156P(F) TLYU156P(F) IF – V F 100 IV – IF 1000 Ta = 25°C (mA) Luminous intensity IV (mcd) 50 Forward current IF 20 10 5 2 1 1.6 1.8 2.0 2.2 2.4 Forward voltage VF 500 200 100 50 20 10 2.6 Ta = 25°C 1 2 5 (V) 10 20 Forward current IF 50 100 640 660 (mA) Relative Luminous Intensity – Wavelength IV – Tc 10 1.0 IF = 20mA Ta = 25°C Relative luminous intensity Relative luminous intensity IV 5 2 1 0.5 0.8 0.6 0.4 0.2 0.2 0.1 −25 0 25 75 50 0 540 100 560 Case temperature Tc (°C) 600 580 Wavelength λ (nm) Radiation Pattern IF – Ta 40 20° 10° 10° 20° 30° 30° 40° 40° 50° 50° 60° 60° 70° 70° 80° 80° 90° Allowable forward current IF (mA) Ta = 25°C 0° 0 0.2 620 0.4 0.6 0.8 90° 1.0 30 20 10 0 0 20 40 60 80 100 Ambient temperature Ta (°C) 5 2007-10-01 TLOU156P(F),TLSU156P(F),TLYU156P(F) RESTRICTIONS ON PRODUCT USE 20070701-EN • The information contained herein is subject to change without notice. • TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc. • The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.).These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in his document shall be made at the customer’s own risk. • The products described in this document shall not be used or embedded to any downstream products of which manufacture, use and/or sale are prohibited under any applicable laws and regulations. • The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patents or other rights of TOSHIBA or the third parties. • GaAs(Gallium Arsenide) is used in this product. The dust or vapor is harmful to the human body. Do not break, cut, crush or dissolve chemically. • Please contact your sales representative for product-by-product details in this document regarding RoHS compatibility. Please use these products in this document in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances. Toshiba assumes no liability for damage or losses occurring as a result of noncompliance with applicable laws and regulations. 6 2007-10-01