EMERSON-NETWORKPOWER BXA30

Embedded Power for
Business-Critical Continuity
Rev.12.17.07
bxa30
1 of 5
BXA30 Series
Single and dual output
Total Power:
30W
Input Voltage: 9 - 18VDC
36 - 75VDC
# of Outputs: Single, dual
Special Features
• Designed to meet telecom
power supply interface
standard ETS300-132-2
• UL, VDE and CSA
safety approvals
• VDE0878 and EN55022
conducted emissions level A
• EN61000-4-2, -3, -4, -5, -6
immunity compliant
• Fixed frequency operation at
350 kHz
• MTBF in excess of 7,005,000
hours (demonstrated)
• Basic insulation system
• Available RoHS compliant
• 2 year warranty
Safety
VDE0805/EN60950/IEC950
File No. 14501-3336-7006
Licence No. 6231
UL1950 File No. E174104
CSA C22.2 No. 950
File No. LR41062C
The BXA30 series, comprising 9 different models, has been
conceived as an applications-specific range of dc-dc converters,
specifically addressing telecommunications, industrial electronics,
test equipment, mobile telecommunications and distributed
power applications. The series offers three wide input voltage
ranges, 9 Vdc to 18 Vdc and 36 Vdc to 75 Vdc, and is available in
single and dual output versions. Designed to meet ETSI telecoms
interface standards ETS300-132-2 and BTR2511, together with
internal filtering to EN55022 level A, safety approval to EN60950
and UL1950, and isolation of 1500 Vdc, the 48 Vdc models are
ideal for telecommunications applications. The 12 V models are
particularly suited to industrial, mobile telecom and test
equipment applications, featuring EN61000-4-2, -3, -4, -5 and -6
immunity compliant. Other features include low output ripple,
overvoltage protection, continuous short circuit protection,
remote enable and remote sense.
Embedded Power for
Business-Critical Continuity
Rev.12.17.07
bxa30
2 of 5
Specifications
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Voltage adjustability
Singles
±10%
Line regulation
LL to HL (single/dual)
±0.2%/±0.4%
Load regulation
FL to NL (single/dual)
±0.2%/±0.4%
Ripple and noise
(20 MHz bandwidth)
3.3 V
5.0 V
All others
All models
60 mV pk-pk
50 mV pk-pk
100 mV pk-pk
20 mV rms
Temperature coefficient
±0.02%/°C
Overvoltage protection
Transient
Short circuit protection
Singles
Duals (single short)
Transient response
135% Vout
Duals (dual short)
Continuous
(See BXA15/30
Design Note 100)
Continuous
25% to 100% load
4.0%
Voltage accuracy
Load cross regulation
±1.5%
Dual output
30% to 100% output variation
3.0%
INPUT SPECIFICATIONS
Input voltage range
Remote ON/OFF
Logic compatibility
ON
OFF
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC part 15 (Note 4)
Level A
EN55022, FCC part 15 (Note 5)
Level B
VDE0878 (Note 4) (48 V)
Level A
EN55022, FCC part 15
Level A
EN61000-4-2, level 3
Perf. criteria 2
EN61000-4-2, level 4
Perf. criteria 2
EN61000-4-5, level 3
Perf. criteria 2
EN61000-4-4, level 3
Perf. criteria 2
EN61000-4-3, level 3
Perf. criteria 2
EN61000-4-6, level 3
Perf. criteria 2
GENERAL SPECIFICATIONS
Efficiency
See table
Isolation voltage
Basic insulation
Input/output
input/case, 48 V models
Switching frequency
Fixed
1500 Vdc
1500 Vdc
350 kHz
Approvals and
standards
(See Note 12)
VDE0805, EN60950
IEC950, UL1950
CSA C22.2 No. 950
Case material
Aluminum substrate
with plastic case
Material flammability
12 Vin nominal
48 Vin nominal
Reverse voltage
protection (See Note 7)
Max. input rise and
fall time
Conducted emissions
9-18 Vdc
36-75 Vdc
Yes
UL94V-0
Weight
MTBF (See Note 9)
120 g (4.24 oz)
Demonstrated @ 25 °C
7,005,000 hours
ENVIRONMENTAL SPECIFICATIONS
48 V
5 V/ms
ETS300-132
CMOS/TTL
Open circuit
<1 Vdc
Thermal performance
Thermal impedance
Baseplate operating
temperature,
(See Notes 6, 8)
Non-operating
-25 °C to +100 °C
-55 °C to +100 °C
Free air convection,
baseplate to air
With heatsink (See Note 8)
6.5 °C/W
5.2 °C/W
Embedded Power for
Business-Critical Continuity
Rev.12.17.07
bxa30
3 of 5
Ordering Information
INPUT
VOLTAGE
OUTPUT
VOLTAGE
OUTPUT
CURRENT (MAX.)
INPUT
CURRENT (1)
TYPICAL
EFFICIENCY
5
6
7
8
9
10
11
12
13
14
15
MODEL
NUMBER (4,6,14,15)
9-18 Vdc
5.0 V
5.0 A
100 mA
80%
±0.2%
±0.2%
BXA30-12S05J
36-75 Vdc
3.3 V
6.0 A
30 mA
75%
±0.2%
±0.2%
BXA30-48S3V3J
36-75 Vdc
3.3 V
8.0 A
30 mA
81%
±0.2%
±0.2%
BXA30-48S3V3/8J (11)
36-75 Vdc
5.0 V
5.0 A
30 mA
80%
±0.4%
±1.0%
BXA30-48S05J
36-75 Vdc
12.0 V
2.5 A
30 mA
85%
±0.2%
±0.2%
BXA30-48S12J
36-75 Vdc
15.0 V
2.0 A
30 mA
87%
±0.2%
±0.2%
BXA30-48S15J
36-75 Vdc
±5.0 V
±2.5 A
30 mA
80%
±0.4%
±0.4%
BXA30-48D05J
36-75 Vdc
±12.0 V
±1.25 A
30 mA
84%
±0.4%
±0.4%
BXA30-48D12J
36-75 Vdc
±15.0 V
±1.0 A
30 mA
86%
±0.4%
±0.4%
BXA30-48D15J
Notes
1
2
3
4
REGULATION
LINE (2)
LOAD (3)
Nominal, at no load.
Low line to high line.
Full load to no-load. For duals, the value stated is for balanced loads.
An optional internal filter is available, which will meet VDE0871 level A,
VDE0878 level A and EN55022 level A. Add the suffix ‘-F’ to the model number,
e.g. BXA30-48S12-FJ. See BXA15 and BXA30 Design Note 100.
For conducted noise operation of the BXA30 to VDE0871, VDE0878 and
EN55022 level B, see BXA15 and BXA30 Design Note 100.
For extended operating temperature, include the heatsink option, ‘-1’ in the
model number. Max. heatsink height is 12.5 mm, e.g. BXA30-48S15-1J
Reverse voltage protection can be implemented by putting a slow blow fuse on
the negative input rail. Rate the fuse for 48 Vdc at 1.5 A and 12 Vdc at 6 A.
The maximum operating ambient temperature, without derating depends on
internal power dissipation and hence efficiency and cooling method. BXA15
and BXA30 Design Note 100 provides detailed thermal calculations and designin details.
Test results to-date are 1,590,000 hours @ 46 ˚C. The MTBF figure shown
includes a calculated acceleration factor of 4.1 based on an activation energy of
-0.55 eV.
Visit the Artesyn website to download a copy of Design Note 100.
This model has the same electrical pin-out and pin pitch spacings as the
drawing on the following page. Dimensions are 76.2 x 76.2 x 14.2 mm, ±0.3
mm.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
If remote sense is not used, connect +sense to +vout and -sense to -vout.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or go to www.powerconversion.com to find a suitable
alternative
Embedded Power for
Business-Critical Continuity
Rev.12.17.07
bxa30
4 of 5
Specifications Contd.
0.76
(19.200.30)
3.02
(76.30 0.30)
2.50
(63.5)
0.20 (5.08)
0.80 (20.32)
0.50 (12.70)
0.302
(7.670.30)
0.20
(5.08)
3
8
4
5
0.95
(24.13)
0.6 (15.24)
1
0.70 (17.78)
0.30 (7.62)
BOTTOM
VIEW
6
2.41
(61.100.30)
0.4 (10.16)
2
7
1.30
(33.02)
1.15
(29.21)
Ø 1.000
8 Places
0.52
(13.300.30)
2.00
(50.80)
Case/Metal Inserts M3.0
(Typ. 4 Places)
SIDE VIEW
ALL DIMENSIONS IN INCHES (mm)
Tolerance .XX 0.02
.XXX 0.005
PIN CONNECTIONS
EXTERNAL OUTPUT TRIMMING
PIN NUMBER
SINGLE OUTPUT
DUAL OUTPUT
1
+ Vin
+ Vin
2
– Vin
– Vin
3
+ Sense (13)
+ Vout
4
Trim
Common
5
– Sense
– Vout
6
+ Vout
No Pin
7
– Vout
No Pin
8
Remote ON/OFF
Remote ON/OFF
Single output models can be
externally trimmed by ±10%
using either method shown.
5
5
TRIM
UP
4
4
TRIM
DOWN
3
3
10K
TRIMPOT
Embedded Power for
Business-Critical Continuity
Rev.12.17.07
bxa30
5 of 5
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
[email protected]
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.