MAKE-PS 312D5FR

www.make-ps.com
E-mail:[email protected]
300FR series
Single & Dual Output
DC/DC Converter
FEATURES
•
•
•
•
•
Up to 64 % Efficiency
Single and Dual Output, 3 watt converter
Available in 5, 12, 24 and 48 VDC Inputs
Industry Standard Pinout
Short Circuit Protection
DESCRIPTIONS
INPUT CHARACTERISTICS
The 300FR series 3 watt power modules are specially
designed to provide low output ripple and tight regulation in
a low-profile 24 pin DIP package. The series consists of 20
models with input voltages of 5V, 12V, 24V and 48V, and offers
regulated output voltages of 5V, 12V, 14V, ±12V and ±15.
Min
Input Voltage
5 VDC Input Models
4.5
12 VDC Input Models 10.8
24 VDC Input Models 21.6
48 VDC Input Models 43.2
Input Fuse Requirements
5 VDC Input Models
12 VDC Input Models
24 VDC Input Models
48 VDC Input Models
Reverse Polarity Input Current
Short Circuit Input Power
Input Filter
The -25oC to +71oC operating temperature range makes it ideal
for data communication equipment, mobile battery driven
equipment, distributed power systems, telecommunication
equipment, mixed analog/digital subsystems, automatic test
instrumentation and industrial robot systems.
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Balance
(Duals)
Line Regulation
Load Regulation
Ripple/Noise
Ripple/Noise
Overload Protection
Short Circuit Protection
Transient Response
Deviation
Transient Recovery Time
Temperature Coefficient
Min Typ Max Unit/Comments
±2.0 ±4.0 % Output voltage at
nominal line & FL
±1.0 ±3.0 % Equal Output
Loads
±0.2 ±0.5 % Output voltage
measured from
min. input line to
maximum
±0.2 ±0.5 % Output voltage
measured from FL
to 10% load
45 50 mV p-p, Nom.Line
@FL, 20MHz B.W.,
using 1 μf bypass
capacitor
75 mV p-p, Over Line,
Load & Temp., 20
MHz B.W.,
using 1 μf bypass
capacitor
%Rated Output Load
120
Continuous,
Automatic Recovery
±6 % deviation of Vout
for a 50% load
change
50 μS for 50% load
change
±0.01 ±0.02 % per degree C
Typ Max Unit/Comments
5
12
24
48
2000
1000
500
200
5.5
13.2
26.4
52.8
VDC
VDC
VDC
VDC
mA; Slow blow type
mA; Slow blow type
mA; Slow blow type
mA; Slow blow type
0.5 Amp
2500 mW
Pi Filter
GENERAL CHARACTERISTICS
Switching Frequency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
MTBF (MIL-HBK-217F)
Min Typ Max Unit/Comments
kHz
40 80
VDC, 1 minute
500
Mohm, 500VDC
1000
100 150 pF, 100kHz, 1Volt
Thousand Hours,
600
+25oC, Ground
Benign
>> B-48
www.make-ps.com
E-mail:[email protected]
ENVIRONMENTAL SPECIFICATIONS
Operating Temp. Range
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Min
-25
-25
-40
PHYSICAL CHARACTERISTICS
Typ Max
+71
+90
+125
95
Cooling
Unit/Comments
o
C; Ambient
o
C; Case
o
C
% Humidity; noncondensing
Free-Air Convection
Unit/Comments
1.25 X 0.8 X 0.4 inches
(31.8 X 20.3 X 10.2 mm)
Black Coated Metal
UL94V-0
14 Grams
Case Size
Case Material
Flammability
Weight
OUTLINE DRAWING
1.25 (31.8)
0.40
(10.2)
SIDE VIEW
0.15
(3.8)
0.020 (0.50)
PIN DIA.
0.08 (2.0)
0.100
(2.54)
1 2 3
10 11 12
BOTTOM VIEW
24 23 22
0.10
(2.5)
0.600 0.80
(15.22) (20.3)
15 14 13
PIN OUT CHART
Pins
Single
1
+ Vin
2
NC
3
NC
10
- Vout
11
+ Vout
12
- Vin
13
- Vin
14
+ Vout
15
- Vout
22
NC
23
NC
24
+ Vin
NC = No Connection
Dual
+ Vin
- Vout
Common
Common
+ Vout
- Vin
- Vin
+ Vout
Common
Common
-V out
+V in
Notes:
1. Unless otherwise specified dimensions are in inches (mm).
Tolerances
Inches
mm
X.XX = ±0.02
X.X = ±0.5
X.XXX= ±0.010
X.XX = ±0.25
Pin :
±0.002
±0.05
All specifications are typical at nominal input, nominal load and 25° C unless otherwise specified.
External, low ESR, 10 microfarad (minimum) capacitor across output is recommended for operation.
>> B-49
www.make-ps.com
E-mail:[email protected]
HOW TO ORDER
HOW TO ORDER
3 12 D XX FR - Y
ROHS Compliant
Series
Nominal
Input Range
Wattage
Output Voltage
Output
Configuration
(S=Single, D=Dual)
MODEL SELECTION CHART
Model
305S5FR
312S5FR
315S5FR
312D5FR
315D5FR
305S12FR
312S12FR
315S12FR
312D12FR
315D12FR
305S24FR
312S24FR
315S24FR
312D24FR
315D24FR
305S48FR
312S48FR
315S48FR
312D48FR
315D48FR
Nominal
Input
Voltage
(VDC)
5
5
5
5
5
12
12
12
12
12
24
24
24
24
24
48
48
48
48
48
Output
Voltage
(VDC)
5
12
15
±12
±15
5
12
15
±12
±15
5
12
15
±12
±15
5
12
15
±12
±15
Full Load
Output
Current
(mA)
600
250
200
±125
±100
600
250
200
±125
±100
600
250
200
±125
±100
600
250
200
±125
±100
No Load
Input
Current
(mA)
100
100
100
100
100
50
50
50
50
50
25
25
25
25
25
15
15
15
15
15
Full Load
Input
Current
(mA)
1000
960
960
1000
1000
420
400
400
420
420
210
195
195
210
210
105
100
100
105
105
Reflected
Ripple
Current
(mA)
100
100
100
100
100
40
40
40
40
40
25
25
25
25
25
15
15
15
15
15
Efficiency
@ FL
(%)
60
62
62
60
60
60
62
62
60
60
60
64
64
60
60
60
62
62
60
60
>> B-50
www.make-ps.com
E-mail:[email protected]
DERATING CURVES
MODEL 300FR - Single Output
Pout %
100
90
80
70
60
50
40
30
20
10
0
-40
100LFM
200LFM
Natural
Convection
400LFM
50
60
70
80
90
100
110
TEMPERATURE ° C
MODEL 300FR - Dual Output
Pout %
100
90
80
70
60
50
40
30
20
10
0
-40
100LFM
200LFM
Natural
Convection
400LFM
50
60
70
80
90
100
110
TEMPERATURE ° C
>> B-51