TOSHIBA SM2G54

SM2G54,SM2L54
TOSHIBA BI−DIRECTIONAL TRIODE THYRISTOR SILICON PLANAR TYPE
SM2G54,SM2L54
AC POWER CONTROL APPLICATIONS
Unit: mm
Repetitive Peak Off−State Voltage : VDRM = 800V
R.M.S. On−State Current
: IT (RMS) = 2A
High Commutation (dv / dt)
: (dv / dt) c = 5V / µs (Min.)
MAXIMUM RATINGS
CHARACTERISTIC
Repetitive Peak Off−State Voltage
R.M.S. On−State Current
(Full Sine Waveform)
Peak One Cycle Surge On−State
Current (Non-Repetitive)
2
I t Limit Value
SYMBOL
RATING
UNIT
VDRM
800
V
IT (RMS)
2
A
ITSM
2
8 (50Hz)
A
8.8 (60Hz)
2
I t
0.32
A s
Critical Rate of Rise of On−State
Current
(Note)
di / dt
50
A / µs
Peak Gate Power Dissipation
PGM
3
W
PG (AV)
0.3
W
Peak Gate Voltage
VFGM
10
V
Peak Gate Current
IGM
1.6
A
Tj
−40~125
°C
Tstg
−40~125
°C
Average Gate Power Dissipation
Junction Temperature
Storage Temperature Range
Note:
1 : T1
2 : T2
3 : GATE
JEDEC
JEITA
TOSHIBA
Weight: 0.82g
−
−
−
di / dt test condition
VDRM = 400V, ITM ≤ 3A, tgw ≥ 10µs, tgr ≤ 250ns, igp = IGT × 2.0
1
2004-07-15
SM2G54,SM2L54
ELECTRICAL CHARACTERISTICS (Ta = 25°C)
CHARACTERISTIC
SYMBOL
MIN
TYP.
MAX
UNIT
−
−
20
µA
T2 (+) , Gate (+)
−
−
1.5
T2 (+) , Gate (−)
−
−
1.5
III
T2 (−) , Gate (−)
−
−
1.5
I
T2 (+) , Gate (+)
−
−
10
T2 (+) , Gate (−)
−
−
10
T2 (−) , Gate (−)
−
−
10
−
−
2.0
V
0.2
−
−
V
VD = 12V, ITM = 1A
−
−
10
mA
Junction to Ambient, AC
−
−
83
°C / W
Repetitive Peak Off−State Current
TEST CONDITION
IDRM
VDRM = 800V
VGT
VD = 12V,
RL = 20Ω
I
Gate Trigger Voltage
Gate Trigger Current
II
II
IGT
VD = 12V,
RL = 20Ω
III
Peak On−State Voltage
VTM
ITM = 3A
Gate Non−Trigger Voltage
VGD
VD = 800V, Tc = 125°C
Holding Current
Thermal Resistance
IH
Rth (j−a)
V
mA
Critical Rate of Rise of Off−State Voltage
dv / dt
VDRM = 800V, Tj = 125°C
Exponential Rise
50
−
−
V / µs
Critical Rate of Rise of Off−State Voltage
at Communication
(dv / dt) c
VDRM = 400V, Tj = 80°C
(di / dt) c = − 0.5A / ms
5
−
−
V / µs
MARKING
Lot No.
(Weekly code)
Part No. (or brevity code)
M2G54 or M2L54
With underline:
Lead (Pb)-Free or
Lead (Pb)-Free Finish
2
2004-07-15
SM2G54,SM2L54
3
2004-07-15
SM2G54,SM2L54
Ta MAXT(AV) - IT(RMS)
PT(AV) - IT(RMS)
140
MAXIMUM ALLOWABLE AMBIENT
TEMPERATURE Ta MAX.( °C)
3
2.5
2
1.5
1
0.5
0
120
100
80
60
40
20
0
0
0.5
1
1.5
2
2.5
0
R.M.S. ON-STATE CURRENT IT(RMS)
0.5
1
IT(RMS)
1.5
2
R.M.S. ON-STATE CURRENT IT(RMS)
TRANSIENT THERMAL IMPEDANCE
(JUNCTION TO AMBIENT)
TRANSIENT THERMAL IMPEDANCE
rth(j-a) .( °C/W)
AVERAGE ON-STATE POWER
PT (AV) (W)
3.5
100
10
1
0.1
0.001
0.01
0.1
1
10
100
1000
TIME t (s)
4
2004-07-15
SM2G54,SM2L54
RESTRICTIONS ON PRODUCT USE
000707EAA
• TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
• The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
• The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other
rights of the third parties which may result from its use. No license is granted by implication or otherwise under
any intellectual property or other rights of TOSHIBA CORPORATION or others.
• The information contained herein is subject to change without notice.
5
2004-07-15