New Product DFL15005S thru DFL1510S Vishay General Semiconductor Low Profile Miniature Glass Passivated Single-Phase Surface Mount Bridge Rectifiers FEATURES • Low profile: typical height of 2.5 mm - • UL recognition, file number E54214 • Ideal for automated placement + ~ • High surge current capability • Meets MSL level 1, per J-STD-020, LF maximum peak of 250 °C ~ • Solder dip 260 °C, 40 s ~ - ~ + • Compliant to RoHS directive 2002/95/EC and in accordance to WEEE 2002/96/EC TYPICAL APPLICATIONS General purpose use in ac-to-dc bridge full wave rectification for SMPS, lighting ballaster, adapter, battery charger, home appliances, office equipment, and telecommunication applications. Case Style Low Pro le DFS PRIMARY CHARACTERISTICS IF(AV) 1.5 A VRRM 50 V to 1000 V IFSM 50 A IR 5 μA VF 1.1 V TJ max. 150 °C MECHANICAL DATA Case: Low profile DFS Epoxy meets UL 94 V-0 flammability rating Terminals: Matte tin plated leads, solderable per J-STD-002 and JESD22-B102 E3 suffix for consumer grade, meets JESD 201 class 1A whisker test Polarity: As marked on body MAXIMUM RATINGS (TA = 25 °C unless otherwise noted) SYMBOL DFL 15005S DFL 1501S DFL 1502S DFL 1504S DFL 1506S DFL 1508S DFL 1510S UNIT Maximum repetitive peak reverse voltage VRRM 50 100 200 400 600 800 1000 V Maximum RMS voltage VRMS 35 70 140 280 420 560 700 V Maximum DC blocking voltage VDC 50 100 200 400 600 800 1000 V PARAMETER Maximum average forward output rectified current at TA = 40 °C IF(AV) (1) 1.5 A Peak forward surge current single half sine-wave superimposed on rated load IFSM 50 A I2t 10 A2s TJ, TSTG - 55 to + 150 °C Rating for fusing (t < 8.3 ms) Operating junction and storage temperature range Note (1) Units mounted on P.C.B. with 0.51" x 0.51" (13 mm x 13 mm) copper pads Document Number: 88874 Revision: 02-Mar-10 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] www.vishay.com 1 New Product DFL15005S thru DFL1510S Vishay General Semiconductor ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) TEST CONDITIONS PARAMETER Max. instantaneous forward voltage drop per diode Maximum DC reverse current at rated DC blocking voltage per diode SYMBOL 1.5 A DFL 15005S DFL 1501S DFL 1502S DFL 1504S VF DFL 1506S DFL 1508S DFL 1510S UNIT 1.1 TA = 25 °C V 5.0 IR μA TA = 125 °C 500 Typical junction capacitance per diode CJ (1) 16 pF Note (1) Measured at 1.0 MHz and applied reverse voltage of 4.0 V THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER SYMBOL Typical thermal resistance DFL 15005S DFL 1501S DFL 1502S DFL 1504S RθJA (1) 40 (1) 15 RθJL DFL 1506S DFL 1508S DFL 1510S UNIT °C/W Note (1) Units mounted on P.C.B. with 0.51" x 0.51" (13 mm x 13 mm) copper pads ORDERING INFORMATION (Example) PREFERRED P/N UNIT WEIGHT (g) PREFERRED PACKAGE CODE BASE QUANTITY DELIVERY MODE DFL1506S-E3/45 0.341 45 50 Tube DFL1506S-E3/77 0.341 77 1500 13" diameter paper tape and reel RATINGS AND CHARACTERISTICS CURVES (TA = 25 °C unless otherwise noted) 60 50 Hz Resistive or Inductive Load Peak Forward Surge Current (A) Average Forward Current (A) 2.0 1.5 1.0 0.5 TJ = 150 °C Single Sine-Wave 50 40 30 20 10 0 0 20 40 60 80 100 120 140 160 1 10 100 Ambient Temperature (°C) Number of Cycles at 50 Hz Fig. 1 - Forward Current Derating Curve Per Diode Fig. 2 - Maximum Non-Repetitive Peak Forward Surge Current Per Diode www.vishay.com 2 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] Document Number: 88874 Revision: 02-Mar-10 New Product DFL15005S thru DFL1510S Vishay General Semiconductor 100 TJ = 150 °C 1 Junction Capacitance (pF) Instantaneous Forward Current (A) 10 TJ = 125 °C TJ = 25 °C 0.1 TJ = 25 °C Pulse Width = 300 μs 1 % Duty Cycle 0.01 0.4 TJ = 25 °C f = 1.0 MHz Vsig = 50 mVp-p 10 1 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 10 1 1.4 Instantaneous Forward Voltage (V) 100 Reverse Voltage (V) Fig. 3 - Typical Forward Voltage Characteristics Per Diode Fig. 5 - Typical Junction Capacitance Per Diode Instantaneous Reverse Leakage Current (μA) 1000 TJ = 150 °C 100 TJ = 125 °C 10 1 TJ = 25 °C 0.1 0.01 10 20 30 40 50 60 70 80 90 100 Percent of Rated Peak Reverse Voltage (%) Fig. 4 - Typical Reverse Characteristics Per Diode PACKAGE OUTLINE DIMENSIONS in inches (millimeters) Case Style Low Profile DFS 0.205 (5.2) 0.195 (5.0) 0.047 (1.20) 0.040 (1.02) Mounting Pad Layout 0.047 Min. (1.20 Min.) 0.404 Max. (10.26 Max.) 0.060 Min. (1.52 Min.) 0.335 (8.51) 0.320 (8.13) 45o 0.013 (0.330) 0.009 (0.241) 0.404 (10.3) 0.386 (9.80) 0.255 (6.5 ) 0.245 (6.2 ) 0.205 (5.2) 0.195 (5.0) 0.102 (2.60) 0.094 (2.40) 0.060 (1.524) 0.040 (1.016) 0.013 (0.330) 0.003 (0.076) Document Number: 88874 Revision: 02-Mar-10 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] www.vishay.com 3 Legal Disclaimer Notice Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Document Number: 91000 Revision: 11-Mar-11 www.vishay.com 1