CAT5259 Quad Digitally Programmable Potentiometers (DPP™) with 256 Taps and I²C Interface FEATURES DESCRIPTION Four linear taper digitally programmable potentiometers The CAT5259 is four digitally programmable poten– tiometers (DPPs™) integrated with control logic and 16 bytes of NVRAM memory. Each DPP consists of a series of resistive elements connected between two externally accessible end points. The tap points between each resistive element are connected to the wiper outputs with CMOS switches. A separate 8-bit control register (WCR) independently controls the wiper tap switches for each DPP. Associated with each wiper control register are four 8-bit non-volatile memory data registers (DR) used for storing up to four wiper settings. Writing to the wiper control register or any of the non-volatile data registers is via a I²C serial bus. On power-up, the contents of the first data register (DR0) for each of the four potentiometers is automatically loaded into its respective wiper control registers. 256 resistor taps per potentiometer End to end resistance 50 kΩ or 100 kΩ Potentiometer control and memory access via I²C interface Low wiper resistance, typically 100 Ω Nonvolatile memory storage for up to four wiper settings for each potentiometer Automatic recall of saved wiper settings at power up 2.5 to 6.0 volt operation Standby current less than 1 µA 1,000,000 nonvolatile WRITE cycles 100 year nonvolatile memory data retention The CAT5259 can be used as a potentiometer or as a two terminal, variable resistor. It is intended for circuit level or system level adjustments in a wide variety of applications. It is available in the 0ºC to 70ºC commercial and -40ºC to 85ºC industrial operating temperature ranges and offered in a 24-lead SOIC and TSSOP package. 24-lead SOIC and 24-lead TSSOP packages Industrial temperature range For Ordering Information details, see page 15. FUNCTIONAL DIAGRAM PIN CONFIGURATION SOIC (W) TSSOP (Y) NC 1 24 A3 A0 2 23 SCL RW3 3 22 RL2 RH3 4 21 RH2 RL3 5 20 RW2 NC 6 19 NC VCC 7 18 GND RLO 8 17 RW1 RHO 9 16 RH1 RWO 10 15 RL1 A2 11 14 A1 12 © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice RH0 SCL SDA I²C BUS INTERFACE RH1 RH2 RH3 WIPER CONTROL REGISTERS RW0 RW1 WP A0 A1 A2 A3 CONTROL LOGIC NONVOLATILE DATA REGISTERS RW2 RW3 RL0 RL1 RL2 RL3 13 SDA 1 Doc. No. MD-2000 Rev. J CAT5259 PIN DESCRIPTIONS Pin # 1 Name SCL: Serial Clock The CAT5259 serial clock input pin is used to clock all data transfers into or out of the device. Function NC No Connect 2 A0 Device Address, LSB 3 RW3 Wiper Terminal for Potentiometer 3 4 RH3 High Reference Terminal for Potentiometer 3 5 RL3 Low Reference Terminal for Potentiometer 3 6 NC No Connect 7 VCC Supply Voltage 8 RL0 Low Reference Terminal for Potentiometer 0 9 RH0 High Reference Terminal for Potentiometer 0 10 RW0 Wiper Terminal for Potentiometer 0 11 A2 Device Address 12 ¯¯¯ WP Write Protection 13 SDA Serial Data Input/Output 14 A1 Device Address 15 RL1 Low Reference Terminal for Potentiometer 1 16 RH1 High Reference Terminal for Potentiometer 1 17 RW1 Wiper Terminal for Potentiometer 1 18 GND Ground 19 NC No Connect 20 RW2 Wiper Terminal for Potentiometer 2 21 RH2 High Reference Terminal for Potentiometer 2 22 RL2 Low Reference Terminal for Potentiometer 2 23 SCL Bus Serial Clock 24 A3 Device Address SDA: Serial Data The CAT5259 bidirectional serial data pin is used to transfer data into and out of the device. The SDA pin is an open drain output and can be wire-Ored with the other open drain or open collector I/Os. A0, A1, A2, A3: Device Address Inputs These inputs set the device address when addressing multiple devices. A total of sixteen devices can be addressed on a single bus. A match in the slave address must be made with the address input in order to initiate communication with the CAT5259. RH, RL: Resistor End Points The four sets of RH and RL pins are equivalent to the terminal connections on a mechanical potentiometer. RW: Wiper The four RW pins are equivalent to the wiper terminal of a mechanical potentiometer. ¯¯¯ WP: Write Protect Input The ¯¯¯ WP pin when tied low prevents non-volatile writes to the device (change of wiper control register is allowed) and when tied high or left floating normal read/write operations are allowed. See Write Protection on page 6 for more details. DEVICE OPERATION The CAT5259 is four resistor arrays integrated with a I²C serial interface logic, four 8-bit wiper control registers and sixteen 8-bit, non-volatile memory data registers. Each resistor array contains 255 separate resistive elements connected in series. The physical ends of each array are equivalent to the fixed terminals of a mechanical potentiometer (RH and RL). The tap positions between and at the ends of the series resistors are connected to the output wiper terminals (RW) by a CMOS transistor switch. Only one tap point for each potentiometer is connected to its wiper terminal at a time and is determined by the value of the wiper control register. Data can be read or written to the wiper control registers or the non-volatile memory data registers via the I²C bus. Additional instructions allow data to be transferred between the wiper control registers and each respective potentiometer's non-volatile data registers. Also, the device can be instructed to operate in an "increment/decrement" mode. Doc. No. MD-2000 Rev. J 2 © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice CAT5259 ABSOLUTE MAXIMUM RATINGS(1) Parameters Temperature Under Bias Storage Temperature Voltage on Any Pin with Respect to VSS(1) (2) VCC with Respect to Ground Package Power Dissipation Capability (TA = 25ºC) Lead Soldering Temperature (10 s) Wiper Current Ratings -55 to +125 -65 to +150 -2.0 to +VCC + 2.0 -2.0 to +7.0 1.0 300 ±6 Units ºC °C V V W ºC mA Ratings +2.5 to +6 -40 to +85 Units V °C RECOMMENDED OPERATING CONDITIONS Parameters VCC Industrial Temperature POTENTIOMETER CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.) Symbol RPOT RPOT IW RW RW VTERM VN TCRPOT TCRATIO CH/CL/CW fc Parameter Potentiometer Resistance (100 kΩ) Potentiometer Resistance (50 kΩ) Potentiometer Resistance Tolerance RPOT Matching Power Rating Wiper Current Wiper Resistance Wiper Resistance Voltage on any RH or RL Pin Noise Resolution Absolute Linearity (5) Relative Linearity (6) Temperature Coefficient of RPOT Ratiometric Temp. Coefficient Potentiometer Capacitances Frequency Response Test Conditions Min Limits Typ. 100 50 25°C, each pot IW = ±3 mA @ VCC = 3 V IW = ±3 mA @ VCC = 5 V VSS = 0 V (4) 200 100 VSS Max. kΩ kΩ ±20 % 1 50 +3 300 150 VCC % mW mA Ω Ω V 0.4 RW(n)(actual)-R(n)(expected)(8) RW(n+1)-[RW(n)+LSB](8) (4) (4) (4) RPOT = 50 kΩ (4) ±1 ±0.2 ±300 20 10/10/25 0.4 Units nV√Hz % LSB (7) LSB (7) ppm/ºC ppm/ºC pF MHz Notes: (1) Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions outside of those listed in the operational sections of this specification is not implied. Exposure to any absolute maximum rating for extended periods may affect device performance and reliability. (2) The minimum DC input voltage is –0.5 V. During transitions, inputs may undershoot to –2.0 V for periods of less than 20 ns. Maximum DC voltage on output pins is VCC +0.5 V, which may overshoot to VCC +2.0 V for periods of less than 20 ns. (3) Latch-up protection is provided for stresses up to 100 mA on address and data pins from –1 V to VCC +1 V. (4) This parameter is tested initially and after a design or process change that affects the parameter. (5) Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a potentiometer. (6) Relative linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a potentiometer. It is a measure of the error in step size. (7) LSB = RTOT / 255 or (RH - RL) / 255, single pot (8) n = 0, 1, 2, ..., 255 © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice 3 Doc. No. MD-2000 Rev. J CAT5259 D.C. OPERATING CHARACTERISTICS VCC = +2.5V to +6.0V, unless otherwise specified. Symbol Parameter Test Conditions ICC1 Power Supply Current ICC2 Min Max Units fSCL = 400 kHz, SDA = Open VCC = 6 V, Inputs = GND 1 mA Power Supply Current Non-volatile WRITE fSCK = 400 kHz, SDA Open VCC = 6 V, Input = GND 5 mA ISB Standby Current (VCC = 5 V) VIN = GND or VCC, SDA = Open 5 µA ILI Input Leakage Current VIN = GND to VCC 10 µA ILO Output Leakage Current VOUT = GND to VCC 10 µA VIL Input Low Voltage -1 VCC x 0.3 V VIH Input High Voltage VCC x 0.7 VCC + 1.0 V VOL1 Output Low Voltage (VCC = 3 V) 0.4 V IOL = 3 mA CAPACITANCE TA = 25ºC, f = 1.0 MHz, VCC = 5 V Symbol Test Conditions (1) Input/Output Capacitance (SDA) (1) Input Capacitance (A0, A1, A2, A3, SCL, ¯¯¯ WP) CI/O CIN Max. Units VI/O = 0 V 8 pF VIN = 0 V 6 pF A.C. CHARACTERISTICS 2.5 V - 6.0 V Symbol fSCL (1) TI tAA tBUF (1) Parameter Max. Units Clock Frequency 400 kHz Noise Suppression Time Constant at SCL, SDA Inputs 200 ns 1 µs Min. SLC Low to SDA Data Out and ACK Out Time the bus must be free before a new transmission can start 1.2 µs Start Condition Hold Time 0.6 µs tLOW Clock Low Period 1.2 µs tHIGH Clock High Period 0.6 µs tSU:STA Start Condition SetupTime (for a Repeated Start Condition) 0.6 µs tHD:DAT Data in Hold Time 0 ns tSU:DAT Data in Setup Time 50 ns tHD:STA (1) tR (1) tF tSU:STO tDH SDA and SCL Rise Time 0.3 SDA and SCL Fall Time 300 µs ns Stop Condition Setup Time 0.6 µs Data Out Hold Time 100 ns Notes: (1) This parameter is tested initially and after a design or process change that affects the parameter. Doc. No. MD-2000 Rev. J 4 © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice CAT5259 POWER UP TIMING (1)(2) Symbol Parameter Max Units tPUR Power-up to Read Operation 1 ms tPUW Power-up to Write Operation 1 ms Min Max Units WIPER TIMING Symbol Parameter tWRPO Wiper Response Time After Power Supply Stable 5 10 µs tWRL Wiper Response Time After Instruction Issued 5 10 µs Max Units 5 ms WRITE CYCLE LIMITS Symbol tWR (3) Parameter Write Cycle Time RELIABILITY CHARACTERISTICS Symbol Parameter Reference Test Method (4) Endurance MIL-STD-883, Test Method 1033 1,000,000 Cycles/Byte Data Retention MIL-STD-883, Test Method 1008 100 Years ESD Susceptibility MIL-STD-883, Test Method 3015 2000 V Latch-Up JEDEC Standard 17 100 mA NEND TDR(4) VZAP(4) ILTH(4) Min Max Units Figure 1. Bus Timing tF tHIGH tLOW tR tLOW SCL tSU:STA tHD:STA tHD:DAT tSU:DAT tSU:STO SDA IN tAA tDH tBUF SDA OUT Notes: (1) This parameter is tested initially and after a design or process change that affects the parameter. (2) tPUR and tPUW are delays required from the time VCC is stable until the specified operation can be initiated. (3) The write cycle is the time from a valid stop condition of a write sequence to the end of the internal program/erase cycle. During the write cycle, the bus interface circuits are disabled, SDA is allowed to remain high, and the device does not respond to its slave address. (4) This parameter is tested initially and after a design or process change that affects the parameter. © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice 5 Doc. No. MD-2000 Rev. J CAT5259 The following defines the features of the I²C bus protocol: The CAT5259 responds with an acknowledge after receiving a START condition and its slave address. If the device has been selected along with a write operation, it responds with an acknowledge after receiving each 8-bit byte. (1) Data transfer may be initiated only when the bus is not busy. (2) During a data transfer, the data line must remain stable whenever the clock line is high. Any changes in the data line while the clock is high will be interpreted as a START or STOP condition. When the CAT5259 is in a READ mode it transmits 8 bits of data, releases the SDA line, and monitors the line for an acknowledge. Once it receives this acknowledge, the CAT5259 will continue to transmit data. If no acknowledge is sent by the Master, the device terminates data transmission and waits for a STOP condition. The device controlling the transfer is a master, typically a processor or controller, and the device being controlled is the slave. The master will always initiate data transfers and provide the clock for both transmit and receive operations. Therefore, the CAT5259 will be considered a slave device in all applications. WRITE OPERATIONS SERIAL BUS PROTOCOL In the Write mode, the Master device sends the START condition and the slave address information to the Slave device. After the Slave generates an acknowledge, the Master sends the instruction byte that defines the requested operation of CAT5259. The instruction byte consist of a four-bit opcode followed by two register selection bits and two pot selection bits. After receiving another acknowledge from the Slave, the Master device transmits the data to be written into the selected register. The CAT5259 acknowledges once more and the Master generates the STOP condition, at which time if a non-volatile data register is being selected, the device begins an internal programming cycle to non-volatile memory. While this internal cycle is in progress, the device will not respond to any request from the Master device. START Condition The START Condition precedes all commands to the device, and is defined as a HIGH to LOW transition of SDA when SCL is HIGH. The CAT5259 monitors the SDA and SCL lines and will not respond until this condition is met. STOP Condition A LOW to HIGH transition of SDA when SCL is HIGH determines the STOP condition. All operations must end with a STOP condition. Acknowledge Polling The disabling of the inputs can be used to take advantage of the typical write cycle time. Once the stop condition is issued to indicate the end of the host's write operation, the CAT5259 initiates the internal write cycle. ACK polling can be initiated immediately. This involves issuing the start condition followed by the slave address. If the CAT5259 is still busy with the write operation, no ACK will be returned. If the CAT5259 has completed the write operation, an ACK will be returned and the host can then proceed with the next instruction operation. DEVICE ADDRESSING The bus Master begins a transmission by sending a START condition. The Master then sends the address of the particular slave device it is requesting. The four most significant bits of the 8-bit slave address are fixed as 0101 for the CAT5259 (see Figure 5). The next four significant bits (A3, A2, A1, A0) are the device address bits and define which device the Master is accessing. Up to sixteen devices may be individually addressed by the system. Typically, +5V and ground are hard-wired to these pins to establish the device's address. Write Protection The Write Protection feature allows the user to protect against inadvertent programming of the non-volatile data registers. If the ¯¯¯ WP pin is tied to LOW, the data registers are protected and become read only. Similarly, the ¯¯¯ WP pin is going low after start will interrupt non-volatile write to data registers, while ¯¯¯ WP pin going low after an internal write cycle has started will have no effect on any write operation. The CAT5259 will accept both slave addresses and instructions, but the data registers are protected from programming by the device’s failure to send an acknowledge after data is received. After the Master sends a START condition and the slave address byte, the CAT5259 monitors the bus and responds with an acknowledge (on the SDA line) when its address matches the transmitted slave address. Acknowledge After a successful data transfer, each receiving device is required to generate an acknowledge. The Acknowledging device pulls down the SDA line during the ninth clock cycle, signaling that it received the 8 bits of data. Doc. No. MD-2000 Rev. J 6 © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice CAT5259 Figure 2. Write Cycle Timing SCL SDA 8TH BIT ACK BYTE n tWR START CONDITION STOP CONDITION ADDRESS Figure 3. Start/Stop Condition SDA SCL START CONDITION STOP CONDITION Figure 4. Acknowledge Condition SCL FROM MASTER 1 8 9 DATA OUTPUT FROM TRANSMITTER DATA OUTPUT FROM RECEIVER ACKNOWLEDGE START Figure 5. Slave Address Bits CAT5259 * 0 1 0 1 A3 A2 A1 A0 A0, A1, A2 and A3 correspond to pin A0, A1, A2 and A3 of the device. ** A0, A1, A2 and A3 must compare to its corresponding hard wired input pins. © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice 7 Doc. No. MD-2000 Rev. J CAT5259 INSTRUCTION BYTE The next byte sent to the CAT5259 contains the instruction and register pointer information. The four most significant bits used provide the instruction opcode I3 - I0. The R1 and R0 bits point to one of the four data registers of each associated potentiometer. The least two significant bits point to one of four Wiper Control Registers. The format is shown in Table 2. INSTRUCTION AND REGISTER DESCRIPTION SLAVE ADDRESS BYTE The first byte sent to the CAT5259 from the master/processor is called the Slave/DPP Address Byte. The most significant four bits of the slave address are a device type identifier. These bits for the CAT5259 are fixed at 0101[B] (refer to Table 1). Data Register Selection The next four bits, A3 - A0, are the internal slave address and must match the physical device address which is defined by the state of the A3 - A0 input pins for the CAT5259 to successfully continue the command sequence. Only the device which slave address matches the incoming device address sent by the master executes the instruction. The A3 - A0 inputs can be actively driven by CMOS input signals or tied to VCC or VSS. Data Register Selected R1 R0 DR0 0 0 DR1 0 1 DR2 1 0 DR3 1 1 Figure 6. Write Timing BUS ACTIVITY: MASTER SDA LINE S T A R T INSTRUCTION BYTE SLAVE/DPP ADDRESS Fixed Variable op code Register Pot1 WCR Address Address S T O P DR1 WCRDATA S P A C K A C K A C K Table 1. Identification Byte Format Device Type Identifier Slave Address ID3 ID2 ID1 ID0 0 1 0 1 A3 A2 A1 A0 (MSB) (LSB) Table 2. Instruction Byte Format Instruction Opcode I3 I2 Data Register Selection I1 I0 R1 (MSB) Doc. No. MD-2000 Rev. J R0 WCR/Pot Selection P1 P0 (LSB) 8 © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice CAT5259 Register. Any data changes in one of the Data Registers is a non-volatile operation and will take a maximum of 10ms. WIPER CONTROL AND DATA REGISTERS Wiper Control Register (WCR) The CAT5259 contains four 8-bit Wiper Control Registers, one for each potentiometer. The Wiper Control Register output is decoded to select one of 256 switches along its resistor array. The contents of the WCR can be altered in four ways: it may be written by the host via Write Wiper Control Register instruction; it may be written by transferring the contents of one of four associated Data Registers via the XFR Data Register instruction, it can be modified one step at a time by the Increment/decrement instruction (see Instruction section for more details). Finally, it is loaded with the content of its data register zero (DR0) upon power-up. If the application does not require storage of multiple settings for the potentiometer, the Data Registers can be used as standard memory locations for system parameters or user preference data. INSTRUCTIONS Four of the nine instructions are three bytes in length. These instructions are: — Read Wiper Control Register – read the current wiper position of the selected potentiometer in the WCR — Write Wiper Control Register – change current wiper position in the WCR of the selected potentiometer — Read Data Register – read the contents of the selected Data Register — Write Data Register – write a new value to the selected Data Register The Wiper Control Register is a volatile register that loses its contents when the CAT5259 is powereddown. Although the register is automatically loaded with the value in DR0 upon power-up, this may be different from the value present at power-down. Data Registers (DR) Each potentiometer has four 8-bit non-volatile Data Registers. These can be read or written directly by the host. Data can also be transferred between any of the four Data Registers and the associated Wiper Control The basic sequence of the three byte instructions is illustrated in Figure 8. These three-byte instructions Table 3. Instruction Set Instruction Set R1 R0 WCR1/P1 WCR0/P0 Instruction Read Wiper Control Register Write Wiper Control Register I3 I2 I1 I0 1 0 0 1 0 0 1/0 1/0 1 0 1 0 0 0 1/0 1/0 Read Data Register 1 0 1 1 1/0 1/0 1/0 1/0 Write Data Register 1 1 0 0 1/0 1/0 1/0 1/0 XFR Data Register to Wiper Control Register 1 1 0 1 1/0 1/0 1/0 1/0 1 1 1 0 1/0 1/0 1/0 1/0 0 0 0 1 1/0 1/0 0 0 1 0 0 0 1/0 1/0 0 0 0 0 1 0 1/0 1/0 XFR Wiper Control Register to Data Register Gang XFR Data Registers to Wiper Control Registers Gang XFR Wiper Control Registers to Data Register Increment/Decrement Wiper Control Register 0 0 Operation Read the contents of the Wiper Control Register pointed to by P1-P0 Write new value to the Wiper Control Register pointed to by P1-P0 Read the contents of the Data Register pointed to by P1-P0 and R1-R0 Write new value to the Data Register pointed to by P1-P0 and R1-R0 Transfer the contents of the Data Register pointed to by P1-P0 and R1-R0 to its associated Wiper Control Register Transfer the contents of the Wiper Control Register pointed to by P1-P0 to the Data Register pointed to by R1-R0 Transfer the contents of the Data Registers pointed to by R1-R0 of all four pots to their respective Wiper Control Registers Transfer the contents of both Wiper Control Registers to their respective data Registers pointed to by R1-R0 of all four pots Enable Increment/decrement of the Control Latch pointed to by P1-P0 Note: 1/0 = data is one or zero. © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice 9 Doc. No. MD-2000 Rev. J CAT5259 exchange data between the WCR and one of the Data Registers. The WCR controls the position of the wiper. The response of the wiper to this action will be delayed by tWR. A transfer from the WCR (current wiper position), to a Data Register is a write to nonvolatile memory and takes a minimum of tWR to complete. The transfer can occur between one of the four potentiometers and one of its associated registers; or the transfer can occur between all potentiometers and one associated register. — Gang XFR Data Register to Wiper Control Register This transfers the contents of all specified Data Registers to the associated Wiper Control Registers. — Gang XFR Wiper Counter Register to Data Register This transfers the contents of all Wiper Control Registers to the specified associated Data Registers. INCREMENT/DECREMENT COMMAND The final command is Increment/Decrement (Figure 9 and 10). The Increment/Decrement command is different from the other commands. Once the command is issued and the CAT5259 has responded with an acknowledge, the master can clock the selected wiper up and/or down in one segment steps; thereby providing a fine tuning capability to the host. For each SCL clock pulse (tHIGH) while SDA is HIGH, the selected wiper will move one resistor segment towards the RH terminal. Similarly, for each SCL clock pulse while SDA is LOW, the selected wiper will move one resistor segment towards the RL terminal. Four instructions require a two-byte sequence to complete, as illustrated in Figure 7. These instructions transfer data between the host/processor and the CAT5259; either between the host and one of the data registers or directly between the host and the Wiper Control Register. These instructions are: — XFR Data Register to Wiper Control Register This transfers the contents of one specified DataRegister to the associated Wiper Control Register. — XFR Wiper Control Register to Data Register This transfers the contents of the specified Wiper Control Register to the specified associated Data Register. See Instructions format for more detail. Figure 7. Two-Byte Instruction Sequence SDA 0 1 0 1 S ID3 ID2 ID1 ID0 A3 T A R Device ID T A2 A1 A0 A I3 C K Internal Address I2 I1 I0 Instruction Opcode R1 R0 P1 P0 Register Address A C K Pot/WCR Address S T O P Figure 8. Three-Byte Instruction Sequence SDA 0 1 0 1 S ID3 ID2 ID1 ID0 A3 T A Device ID R T A2 A0 A I3 C K Internal Address A1 I2 I1 I0 R1 R0 P1 P0 A C K Data Pot/WCR Register Address Address Instruction Opcode D7 D6 D5 D4 D3 D2 D1 D0 WCR[7:0] or Data Register D[7:0] A C K S T O P Figure 9. Increment/Decrement Instruction Sequence 0 SDA S T A R T 1 0 1 ID3 ID2 ID1 ID0 Doc. No. MD-2000 Rev. J Device ID A3 A2 A1 A0 Internal Address A C K I3 I2 I1 Instruction Opcode 10 I0 R1 R0 P1 P0 A C Pot/WCR K Data Register Address Address I N C 1 I N C 2 I N C n D E C 1 D E C n S T O P © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice CAT5259 Figure 10. Increment/Decrement Timing Limits INC/DEC Command Issued tWRL SCL SDA RW Voltage Out INSTRUCTION FORMAT Read Wiper Control Register (WCR) INSTRUCTION DATA S DEVICE ADDRESSES A A A S T 0 1 0 1 A A A A C 1 0 0 1 0 0 P P C 7 6 5 4 3 2 1 0 C T A K O 3 2 1 0 K 1 0 K R P T Write Wiper Control Register (WCR) S DEVICE ADDRESSES A INSTRUCTION DATA A A S T 0 1 0 1 A A A A C 1 0 1 0 0 0 P P C 7 6 5 4 3 2 1 0 C T A K O 3 2 1 0 K 1 0 K R P T Read Data Register (DR) S DEVICE ADDRESSES A INSTRUCTION DATA A A S T 0 1 0 1 A A A A C 1 0 1 1 R R P P C 7 6 5 4 3 2 1 0 C T A K O 3 2 1 0 K 1 0 1 0 K R P T Write Data Register (DR) S DEVICE ADDRESSES A INSTRUCTION DATA A A S T 0 1 0 1 A A A A C 1 1 0 0 R R P P C 7 6 5 4 3 2 1 0 C T A K O 3 2 1 0 K 1 0 1 0 K R P T © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice 11 Doc. No. MD-2000 Rev. J CAT5259 INSTRUCTION FORMAT (continued) Gang Transfer Data Register (DR) to Wiper Control Register (WCR) INSTRUCTION S DEVICE ADDRESSES A A S T 0 1 0 1 A A A A C 0 0 0 1 R R 0 0 C T A K O 3 2 1 0 K 1 0 R P T Gang Transfer Wiper Control Register (WCR) to Data Register (DR) S DEVICE ADDRESSES A INSTRUCTION A S T 0 1 0 1 A A A A C 1 0 0 0 R R 0 0 C T A K O 3 2 1 0 K 1 0 R P T Transfer Wiper Control Register (WCR) to Data Register (DR) S DEVICE ADDRESSES A INSTRUCTION A S T 0 1 0 1 A A A A C 1 1 1 0 R R P P C T A 3 2 1 0 K 1 0 1 0 K O R P T Transfer Data Register (DR) to Wiper Control Register (WCR) S DEVICE ADDRESSES A INSTRUCTION A S T 0 1 0 1 A A A A C 1 1 0 1 R R P P C T A 3 2 1 0 K 1 0 1 0 K O R P T Increment (I)/Decrement (D) Wiper Control Register (WCR) S DEVICE ADDRESSES A INSTRUCTION A T 0 1 0 1 A A A A C 0 0 1 0 0 0 P P C I I A 3 2 1 0 K 1 0 K \ \ R D D T DATA ... S I I T \ \ O D D P Note: (1) Any write or transfer to the Non-volatile Data Registers is followed by a high voltage cycle after a STOP has been issued. Doc. No. MD-2000 Rev. J 12 © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice CAT5259 PACKAGE OUTLINE DRAWINGS SOIC 24-Lead 300 mils (W) (1)(2) SYMBOL E1 E MIN e PIN#1 IDENTIFICATION MAX A 2.35 2.65 A1 0.10 0.30 A2 2.05 2.55 b 0.31 0.51 c 0.20 0.33 D 15.20 15.40 E 10.11 10.51 E1 7.34 e b NOM 7.60 1.27 BSC h 0.25 0.75 L 0.40 1.27 θ 0° 8° θ1 5° 15° TOP VIEW h D A2 A h θ1 θ θ1 L A1 SIDE VIEW c END VIEW Notes: (1) All dimensions in millimeters. Angle in degrees. (2) Compiles with JEDEC standard MS-013. © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice 13 Doc. No. MD-2000 Rev. J CAT5259 TSSOP 24-Lead 4.4 mm (Y) (1)(2) b SYMBOL MIN NOM A E1 E MAX 1.20 A1 0.05 0.15 A2 0.80 1.05 b 0.19 0.30 c 0.09 0.20 D 7.70 7.80 7.90 E 6.25 6.40 6.55 E1 4.30 4.40 4.50 e 0.65 BSC L 1.00 REF L1 0.50 θ1 0° 0.60 0.70 8° e TOP VIEW D c A2 A θ1 L1 A1 L SIDE VIEW END VIEW Notes: (1) All dimensions in millimeters. Angle in degrees. (2) Compiles with JEDEC standard MS-153. Doc. No. MD-2000 Rev. J 14 © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice CAT5259 EXAMPLE OF ORDERING INFORMATION (1) Prefix Device # Suffix CAT 5259 Company ID W I Package W: SOIC Y: TSSOP -00 Temperature Range I = Industrial (-40ºC to 85ºC) Resistance 50: 50 kΩ 00: 100 kΩ - T1 Tape & Reel T: Tape & Reel 1: 1,000/Reel - SOIC 2: 2,000/Reel - TSSOP Product Number 5259 ORDERING INFORMATION Orderable Part Number Resistance (kΩ) CAT5259WI-50-T1 50 CAT5259WI-00-T1 100 CAT5259YI-50-T2 50 CAT5259YI-00-T2 100 CAT5259WI50 50 CAT5259WI00 100 CAT5259YI50 50 CAT5259YI00 100 Package Lead Finish SOIC TSSOP Matte-Tin SOIC TSSOP Notes: (1) All packages are RoHS-compliant (Lead-free, Halogen-free). (2) The device used in the above example is a CAT5259WI-00-T1 (SOIC, Industrial Temperature, 100 kΩ, Tape & Reel, 1,000/Reel). (3) For additional package and temperature options, please contact your nearest ON Semiconductor Sales office © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice 15 Doc. No. MD-2000 Rev. J CAT5259 REVISION HISTORY Date Rev. Description 12-Nov-04 C Eliminated BGA package in all areas Eliminated Commercial temperature range Added “Green” package marking 18-Mar-04 D Added TSSOP package in all areas 07-May-04 E Updated Functional Diagram Updated Pin Descriptions Updated notes in Absolute Max. Ratings Updated Potentiometer Characteristics table Updated DC Characteristics table Added Wiper table Updated Write Protection text Changed Figure 3 drawing to Start/Stop Condition from Start/Stop Timing Changed Figure 4 title from Acknowledge Timing to Acknowledge Condition Corrected Instruction Format for Gang Transfer Data Register (DR) to Wiper Control Register (WCR) 21-Sep-04 F Updated DC Operating Characteristics table 23-Jan-08 G Updated Example of Ordering Information Updated Package Outline Drawings Added MD- to document number 08-Apr-08 H 26-Nov-08 I Change 2-wire with I²C Update Ordering Part Number table Change logo and fine print to ON Semiconductor 31-Jul-09 J Update Ordering Information table ON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer's technical experts. SCILLC does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner. PUBLICATION ORDERING INFORMATION LITERATURE FULFILLMENT: Literature Distribution Center for ON Semiconductor P.O. Box 5163, Denver, Colorado 80217 USA Phone: 303-675-2175 or 800-344-3860 Toll Free USA/Canada Fax: 303-675-2176 or 800-344-3867 Toll Free USA/Canada Email: [email protected] Doc. No. MD-2000 Rev. J N. American Technical Support: 800-282-9855 Toll Free USA/Canada Europe, Middle East and Africa Technical Support: Phone: 421 33 790 2910 Japan Customer Focus Center: Phone: 81-3-5773-3850 16 ON Semiconductor Website: www.onsemi.com Order Literature: http://www.onsemi.com/orderlit For additional information, please contact your local Sales Representative © 2009 SCILLC. All rights reserved. Characteristics subject to change without notice