POWER-SYSTEMS DUS-1205

DC-DC Converter UNIT
DU Series ( 5W UNREGULATED DC-DC CONVERTER )
FEATURES
z
z
1000VDC ISOLATION
HIGH EFFICIENCY
INTERNAL FILTERING
LOW COST
NO EXTERNAL COMPONENTS
REQUIRED
UP TO 5W UNREGULATED
OUTPUT POWER
DUAL IN LINE PACKAGE
100% BURNED IN
z
LOW NOISE
z
OUTPUT SPECIFICATIONS
z
z
z
z
z
z
z
Voltage Setpoint Accuracy
+/-3% max
Temperature Coefficient
+/-0.03%/ OC
Ripple & Noise (20MHz
INPUT SPECIFICATIONS
Input Voltage Range
+/-10% max
Input Filter
Pi Network
100mVp-p max
BW)
Line Regulation1
+/-1.2% max
Load Regulation2
+/-8% max
Short Circuit Protection
z
Momentary
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Cooling
z
GENERAL SPECIFICATIONS
Efficiency
Isolation Voltage3
1000 VDC min
Isolation Resistance
9
10 ohms min
-25 OC to +70 OC
Switching Frequency
50 KHz min
-55 OC to +100 OC
Isolation Capacitance
80pF max
Weight
19.2g Typ
Free-Air Convection
Case Material
ALL SPECIFICATIONS TYPICAL AT NOMINAL
LINE,
FULL
LOAD
,
AND
79%-91%
25
O
C
Case Size
Non-Conductive Plastic
33.0mm*33.0mm*10.2mm
UNLESS
OTHERWISE NOTED.
1
Line Regulation is for a 1.0% change in input Voltage.
2
Load Regulation is for output load current change from 20% to 100%.
3
For 10 seconds
www.Power-Systems.de
Page: 1 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
DU Series ( 5W UNREGULATED DC-DC CONVERTER )
z SELECTION GUIDE
5W OUTPUT
MODEL
NUMBER
INPUT
OUTPUT
OUTPUT
VOLTAGE VOLTAGE CURRENT
(VDC)
(VDC)
(mA)
INPUT
CURRENT(mA)
EFF
ISOLATION
FULL
NO
(%)
(VDC)
LOAD
LOAD
DUS-0503.3
5
3.3
1500
1270
80
79
1000
DUS-0505
5
5
1000
1210
80
83
1000
DUS-0512
5
12
417
1150
80
87
1000
DUS-0515
5
15
333
1150
80
87
1000
DUS-0524
5
24
208
1152
80
87
1000
DUD-0505
5
+/-5
+/-500
1210
80
83
1000
DUD-0512
5
+/-12
+/-208
1150
80
87
1000
DUD-0515
5
+/-15
+/-167
1150
80
87
1000
DUS-1205
12
5
1000
496
40
84
1000
DUS-1212
12
12
417
479
40
87
1000
DUS-1215
12
15
333
479
40
87
1000
DUS-1224
12
24
208
482
40
86
1000
DUD-1205
12
+/-5
+/-500
496
40
84
1000
DUD-1212
12
+/-12
+/-208
479
40
87
1000
DUD-1215
12
+/-15
+/-167
479
40
87
1000
DUS-2405
24
5
1000
251
20
83
1000
DUS-2412
24
12
417
245
20
85
1000
DUS-2415
24
15
333
239
20
87
1000
DUS-2424
24
24
208
241
20
86
1000
DUD-2405
24
+/-5
+/-500
251
20
83
1000
DUD-2412
24
+/-12
+/-208
230
20
90
1000
DUD-2415
24
+/-15
+/-167
230
20
90
1000
DUS-4824
48
24
208
125
15
83
1000
Note: Other input to output voltages may be available. Please contact factory.
www.Power-Systems.de
Page: 2 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
DU Series ( 5W UNREGULATED DC-DC CONVERTER )
z SIMPLIFIED SCHEMATIC
SINGLE OUTPUT
+Vin
DUAL OUTPUT
+Vin
+Vout
OSCILLATOR
DRIVER
-Vin
+Vout
OSCILLATOR
DRIVER
-Vout
COMMON
-Vin
-Vout
z MECHANICAL DIMENSIONS
PIN
SINGLE
DUAL
1
+Vin
+Vin
2
-Vin
-Vin
3
+Vout
+Vout
4
NO PIN
Common
5
-Vout
-Vout
z RECOMMENDED FOOTPRINT DETAILS
www.Power-Systems.de
Page: 3 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
DU Series ( 5W UNREGULATED DC-DC CONVERTER )
z TYPICAL APPLICATIONS
SINGLE OUTPUT
INPUT
DUAL OUTPUT
OUTPUT
INPUT
OUTPUT
+Vout
+Vin
+Vin
+Vout
LOAD1
LOAD
DC-DC
CONVERTER
-Vin
Common
DC-DC
CONVERTER
-Vin
-Vout
LOAD2
-Vout
z TYPICAL PERFORMANCE CUREVES
Specifications typical at ta=25 OC , nominal input voltage , rated output current unless otherwise specified.
DERATING CURVE
OUTPUT POWER(%)
EFFICIENCY(%)
EFFICIENCY VS LOAD
80.0
60.0
40.0
20.0
0.0
0
20
40
60
80
125%
100%
75%
SAFE
OPERATING
AREA
50%
25%
0%
100
-25
% OF RATED LOAD(%)
0
25
50
70
100
TA(degree C)
DU SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
No external capacitance is required for operation of the DU series.
To meet the reflected ripple requirements of the converter,an input impedance of less than 0.5 ohm
from DC to 100KHz is required.
External output capacitance is not required for operation,however it is recommended that 10uF
tantalum and 0.1uF ceramic capacitance be selected for reduced system noise.
Additional output capacitance may be added for increased filtering,but should not exceed 220uF.
www.Power-Systems.de
Page: 4 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
DU Series ( 5W UNREGULATED DC-DC CONVERTER )
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground and
connecting –OUT as the negative output.
FOR MORE INFORMATION CALL:
Power Systems – The Power Solution
Ilsfeld-Auenstein ( Germany ) Dörnet 8
Tel: + 49 / 70 62 / 67 59 – 6
E-mail: [email protected]
Home Page: www.Power-Systems.de
www.Power-Systems.de
Page: 5 / 5
Fax: + 49 / 70 62 / 67 59 -80
Version: 4-Oct-02