FUJITSU MBM29F017A

FUJITSU SEMICONDUCTOR
DATA SHEET
DS05-20843-3E
FLASH MEMORY
CMOS
16M (2M × 8) BIT
MBM29F017A-70/-90/-12
■ FEATURES
• Single 5.0 V read, write, and erase
Minimizes system level power requirements
• Compatible with JEDEC-standard commands
Pinout and software compatible with single-power supply Flash
Superior inadvertent write protection
• 48-pin TSOP, 40-pin SON
• Minimum 100,000 write/erase cycles
• High performance
70 ns maximum access time
• Sector erase architecture
Uniform sectors of 64K bytes each
Any combination of sectors can be erased. Also supports full chip erase
• Embedded EraseTM Algorithms
Automatically pre-programs and erases the chip or any sector
• Embedded ProgramTM Algorithms
Automatically programs and verifies data at specified address
• Data Polling and Toggle Bit feature for detection of program or erase cycle completion
• Ready/BUSY output (RY/BY)
Hardware method for detection of program or erase cycle completion
• Low VCC write inhibit ≤ 3.2 V
• Hardware RESET pin
Resets internal state machine to the read mode
• Erase Suspend/Resume
Supports reading or programming data to a sector not being erased
• Sector group protection
Hardware method that disables any combination of sector groups from write or erase operation (a sector group
consists of 4 adjacent sectors of 64K bytes each)
• Temporary sector groups unprotection
Hardware method temporarily enable any combination of sectors from write or erase operations
Embedded Erase™, Embedded Program™ and ExpressFlash™ are trademarks of Advanced Micro Devices, Inc.
MBM29F017A-70/-90/-12
■ PACKAGE
48-pin Plastic TSOP (I)
Marking Side
Marking Side
FPT-48P-M19
FPT-48P-M20
40-pin Plastic SON
LCC-40P-M02
2
MBM29F017A-70/-90/-12
■ GENERAL DESCRIPTION
The MBM29F017A is a 16M-bit, 5.0 V-Only Flash memory organized as 2M bytes of 8 bits each. The 2M bytes
of data is divided into 32 sectors of 64K bytes for flexible erase capability. The 8 bit of data will appear on DQ 0
to DQ7. The MBM29F017A is offered in a 48-pin TSOP package. This device is designed to be programmed insystem with the standard system 5.0 V VCC supply. A 12.0 V VPP is not required for program or erase operations.
The device can also be reprogrammed in standard EPROM programmers.
The standard MBM29F017A offers access times between 70 ns and 120 ns allowing operation of high-speed
microprocessors without wait states. To eliminate bus contention the device has separate chip enable (CE), write
enable (WE), and output enable (OE) controls.
The MBM29F017A is command set compatible with JEDEC standard single-supply Flash standard. Commands
are written to the command register using standard microprocessor write timings. Register contents serve as
input to an internal state-machine which controls the erase and programming circuitry. Write cycles also internally
latch addresses and data needed for the programming and erase operations. Reading data out of the device is
similar to reading from 12.0 V Flash or EPROM devices.
The MBM29F017A is programmed by executing the program command sequence. This will invoke the Embedded
ProgramTM Algorithm which is an internal algorithm that automatically times the program pulse widths and verifies
proper cell margin. Each sector can be programmed and verified in less than 0.5 seconds. Erase is accomplished
by executing the erase command sequence. This will invoke the Embedded EraseTM Algorithm which is an
internal algorithm that automatically preprograms the array if it is not already programmed before executing the
erase operation. During erase, the device automatically times the erase pulse widths and verifies proper cell
margin.
This device also features a sector erase architecture. The sector erase mode allows for sectors of memory to
be erased and reprogrammed without affecting other sectors. A sector is typically erased and verified within one
second (if already completely preprogrammed). The MBM29F017A is erased when shipped from the factory.
The MBM29F017A device also features hardware sector group protection. This feature will disable both program
and erase operations in any combination of eight sector groups of memory. A sector group consists of four
adjacent sectors grouped in the following pattern: sectors 0-3, 4-7, 8-11, 12-15, 16-19, 20-23, 24-27, and 28-31.
Fujitsu has implemented an Erase Suspend feature that enables the user to put erase on hold for any period of
time to read data from or program data to a non-busy sector. Thus, true background erase can be achieved.
The device features single 5.0 V power supply operation for both read and program functions. Internally generated
and regulated voltages are provided for the program and erase operations. A low VCC detector automatically
inhibits write operations during power transitions. The end of program or erase is detected by Data Polling of
DQ7, or by the Toggle Bit I feature on DQ6 or RY/BY output pin. Once the end of a program or erase cycle has
been completed, the device automatically resets to the read mode.
The MBM29F017A also has a hardware RESET pin. When this pin is driven low, execution of any Embedded
Program or Embedded Erase operations will be terminated. The internal state machine will then be reset into
the read mode. The RESET pin may be tied to the system reset circuity. Therefore, if a system reset occurs
during the Embedded Program or Embedded Erase operation, the device will be automatically reset to a read
mode. This will enable the system microprocessor to read the boot-up firmware from the Flash memory.
Fujitsu's Flash technology combines years of EPROM and E2PROM experience to produce the highest levels
of quality, reliability, and cost effectiveness. The MBM29F017A memory electrically erases all bits within a sector
simultaneously via Fowler-Nordheim tunneling. The bytes are programmed one byte at a time using the EPROM
programming mechanism of hot electron injection.
3
MBM29F017A-70/-90/-12
■ FLEXIBLE SECTOR-ERASE ARCHITECTURE
• Thirty two 64K byte sectors
• 8 sector groups each of which consists of 4 adjacent sectors in the following pattern; sectors 0-3, 4-7, 8-11,
12-15, 16-19, 20-23, 24-27, and 28-31
• Individual-sector or multiple-sector erase capability
• Sector group protection is user-definable
SA31
64K byte
SA30
64K byte
SA29
64K byte
SA28
64K byte
1FFFFFH
1EFFFFH
1DFFFFH
Sector
Group 7
1CFFFFH
1BFFFFH
1AFFFFH
19FFFFH
18FFFFH
17FFFFH
16FFFFH
15FFFFH
14FFFFH
13FFFFH
12FFFFH
11FFFFH
10FFFFH
32 Sectors Total
0FFFFFH
0EFFFFH
0DFFFFH
0CFFFFH
0BFFFFH
0AFFFFH
09FFFFH
08FFFFH
07FFFFH
06FFFFH
05FFFFH
04FFFFH
4
SA3
64K byte
SA2
64K byte
SA1
64K byte
SA0
64K byte
03FFFFH
02FFFFH
01FFFFH
00FFFFH
000000H
Sector
Group 0
MBM29F017A-70/-90/-12
■ PRODUCT LINE UP
Part No.
MBM29F017A
VCC = 5.0 V ±5%
-70
—
—
VCC = 5.0 V ±10%
—
-90
-12
Max. Address Access Time (ns)
70
90
120
Max. CE Access Time (ns)
70
90
120
Max. OE Access Time (ns)
40
40
50
Ordering Part No.
■ BLOCK DIAGRAM
RY/BY
Buffer
DQ0 to DQ7
RY/BY
VCC
VSS
WE
Input/Output
Buffers
Erase Voltage
Generator
State
Control
RESET
Command
Register
Program Voltage
Generator
Chip Enable
Output Enable
Logic
CE
OE
STB
Low VCC Detector
Timer for
Program/Erase
Address
Latch
STB
Data Latch
Y-Decoder
Y-Gating
X-Decoder
Cell Matrix
A0 to A20
5
MBM29F017A-70/-90/-12
■ CONNECTION DIAGRAMS
TSOP
N.C.
N.C.
A19
A18
A17
A16
A15
A14
A13
A12
CE
VCC
N.C.
RESET
A11
A10
A9
A8
A7
A6
A5
A4
N.C.
N.C.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
(Marking Side)
MBM29F017A
Standard Pinout
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
N.C.
N.C.
A20
N.C.
WE
OE
RY/BY
DQ7
DQ6
DQ5
DQ4
VCC
VSS
VSS
DQ3
DQ2
DQ1
DQ0
A0
A1
A2
A3
N.C.
N.C.
FPT-48P-M19
N.C.
N.C.
A4
A5
A6
A7
A8
A9
A10
A11
RESET
N.C.
VCC
CE
A12
A13
A14
A15
A16
A17
A18
A19
N.C.
N.C.
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
(Marking Side)
MBM29F017A
Reverse Pinout
FPT-48P-M20
6
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
N.C.
N.C.
A3
A2
A1
A0
DQ0
DQ1
DQ2
DQ3
VSS
VSS
VCC
DQ4
DQ5
DQ6
DQ7
RY/BY
OE
WE
N.C.
A20
N.C.
N.C.
MBM29F017A-70/-90/-12
(Continued)
(TOP VIEW)
N.C.
A19
A18
A17
A16
A15
A14
A13
A12
CE
VCC
DQ4
DQ5
DQ6
DQ7
RY/BY
OE
WE
A20
N.C.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
(Marking side)
MBM29F017A
SON-40
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
A4
A5
A6
A7
A8
A9
A10
A11
RESET
VCC
VSS
DQ3
DQ2
DQ1
DQ0
A0
A1
A2
A3
N.C.
LCC-40P-M02
7
MBM29F017A-70/-90/-12
■ LOGIC SYMBOL
Table 1
21
A 0 to A 20
8
MBM29F017A Pin Configuration
Pin
Function
A0 to A20
Address Inputs
DQ0 to DQ7
Data Inputs/Outputs
CE
Chip Enable
OE
Output Enable
WE
Write Enable
RY/BY
Ready-Busy Output
RESET
Hardware Reset Pin/Sector Protection
Unlock
N.C.
No Internal Connection
VSS
Device Ground
VCC
Device Power Supply
DQ0 to DQ7
CE
OE
WE
RESET
RY/BY
Table 2
MBM29F017A User Bus Operations
CE
OE
WE
A0
A1
A6
A9
Auto-Select Manufacturer Code (1)
L
L
H
L
L
L
VID
Code
H
Auto-Select Device Code (1)
L
L
H
H
L
L
VID
Code
H
Read (3)
L
L
H
A0
A1
A6
A9
DOUT
H
Standby
H
X
X
X
X
X
X
HIGH-Z
H
Output Disable
L
H
H
X
X
X
X
HIGH-Z
H
Write
L
H
L
A0
A1
A6
A9
DIN
H
Enable Sector Group Protection (2)
L
VID
X
X
X
VID
X
H
Verify Sector Group Protection (2)
L
L
H
L
H
L
VID
Code
H
Temporary Sector Group Unprotection
X
X
X
X
X
X
X
X
VID
Reset (Hardware)
X
X
X
X
X
X
X
HIGH-Z
L
Operation
Legend: L = VIL, H = VIH, X = VIL or VIH,
DQ0 to DQ7 RESET
= Pulse Input. See DC Characteristics for voltage levels.
Notes: 1. Manufacturer and device codes may also be accessed via a command register write sequence. Refer
to Tables 6.
2. Refer to the section on Sector Group Protection.
3. WE can be VIL if OE is VIL, OE at VIH initiates the write operations.
8
MBM29F017A-70/-90/-12
■ ORDERING INFORMATION
Standard Products
Fujitsu standard products are available in several packages. The order number is formed by a combination of:
MBM29F017
A
-70
PFTN
PACKAGE TYPE
PFTN = 48-Pin Thin Small Outline Package
(TSOP) Standard Pinout
PFTR = 48-Pin Thin Small Outline Package
(TSOP) Reverse Pinout
PNS = 40-Pin Small Outline Nonleaded
Package (SON)
SPEED OPTION
See Product Selector Guide
A = Device Revision
DEVICE NUMBER/DESCRIPTION
MBM29F017
16 Mega-bit (2M × 8-Bit) CMOS Flash Memory
5.0 V-only Read, Write, and Erase
64K Bytes (32 Sectors)
9
MBM29F017A-70/-90/-12
■ FUNCTIONAL DESCRIPTION
Read Mode
The MBM29F017A has two control functions which must be satisfied in order to obtain data at the outputs. CE
is the power control and should be used for a device selection. OE is the output control and should be used to
gate data to the output pins if a device is selected.
Address access time (tACC) is equal to the delay from stable addresses to valid output data. The chip enable
access time (tCE) is the delay from stable addresses and stable CE to valid data at the output pins. The output
enable access time is the delay from the falling edge of OE to valid data at the output pins. (Assuming the
addresses have been stable for at least tACC-tOE time.)
Standby Mode
There are two ways to implement the standby mode on the MBM29F017A device, one using both the CE and
RESET pins; the other via the RESET pin only.
When using both pins, a CMOS standby mode is achieved with CE and RESET inputs both held at VCC ±0.3 V.
Under this condition the current consumed is less than 5 µA. A TTL standby mode is achieved with CE and
RESET pins held at VIH. Under this condition the current is reduced to approximately 1 mA. During Embedded
Algorithm operation, VCC Active current (ICC2) is required even CE = VIH. The device can be read with standard
access time (tCE) from either of these standby modes.
When using the RESET pin only, a CMOS standby mode is achieved with RESET input held at VSS ±0.3 V
(CE = “H” or “L”). Under this condition the current consumed is less than 5 µA. A TTL standby mode is achieved
with RESET pin held at VIL (CE = “H” or “L”). Under this condition the current required is reduced to approximately
1 mA. Once the RESET pin is taken high, the device requires tRH ns of wake up time before outputs are valid for
read access.
In the standby mode the outputs are in the high impedance state, independent of the OE input.
Output Disable
With the OE input at a logic high level (VIH), output from the device is disabled. This will cause the output pins
to be in a high impedance state.
Autoselect
The autoselect mode allows the reading out of a binary code from the device and will identify its manufacturer
and type. This mode is intended for use by programming equipment for the purpose of automatically matching
the device to be programmed with its corresponding programming algorithm. This mode is functional over the
entire temperature range of the device.
To activate this mode, the programming equipment must force VID (11.5 V to 12.5 V) on address pin A9. Two
identifier bytes may then be sequenced from the device outputs by toggling address A0 from VIL to VIH. All
addresses are DON'T CARES except A0, A1, and A6. (See Table 3.)
The manufacturer and device codes may also be read via the command register, for instances when the
MBM29F017A is erased or programmed in a system without access to high voltage on the A9 pin. The command
sequence is illustrated in Table 6. (Refer to Autoselect Command section.)
Byte 0 (A0 = VIL) represents the manufacturer's code (Fujitsu = 04H) and byte 1 (A0 = VIH) the device identifier
code for MBM29F017A = ADH. These two bytes are given in the table 3. All identifiers for manufacturer and
device will exhibit odd parity with DQ7 defined as the parity bit. In order to read the proper device codes when
executing the Autoselect, A1 must be VIL. (See Table 3.)
10
MBM29F017A-70/-90/-12
The Autoselect mode also facilitates the determination of sector group protection in the system. By performing
a read operation at the address location XX02H with the higher order address bits A18, A19, and A20 set to the
desired sector group address, the device will return 01H for a protected sector group and 00H for a non-protected
sector group.
Table 3
MBM29F017A Sector Protection Verify Autoselect Codes
A18 to A20
Type
A6
A1
A0
Code
(HEX) DQ7 DQ6 DQ5 DQ4 DQ3 DQ2 DQ1 DQ0
Manufacture’s
Code
X
X
X
VIL
VIL
VIL
04H
0
0
0
0
0
1
0
0
Device Code
X
X
X
VIL
VIL
VIH
3DH
0
0
1
1
1
1
0
1
Sector Group
Protection
Sector Group
Addresses
VIL
VIH
VIL
01H*
0
0
0
0
0
0
0
1
* : Outputs 01H at protected sector addresses and outputs 00H at unprotected sector addresses.
11
MBM29F017A-70/-90/-12
Table 4
12
Sector Address Table
A20
A19
A18
A17
A16
Address Range
SA0
0
0
0
0
0
000000H to 00FFFFH
SA1
0
0
0
0
1
010000H to 01FFFFH
SA2
0
0
0
1
0
020000H to 02FFFFH
SA3
0
0
0
1
1
030000H to 03FFFFH
SA4
0
0
1
0
0
040000H to 04FFFFH
SA5
0
0
1
0
1
050000H to 05FFFFH
SA6
0
0
1
1
0
060000H to 06FFFFH
SA7
0
0
1
1
1
070000H to 07FFFFH
SA8
0
1
0
0
0
080000H to 08FFFFH
SA9
0
1
0
0
1
090000H to 09FFFFH
SA10
0
1
0
1
0
0A0000H to 0AFFFFH
SA11
0
1
0
1
1
0B0000H to 0BFFFFH
SA12
0
1
1
0
0
0C0000H to 0CFFFFH
SA13
0
1
1
0
1
0D0000H to 0DFFFFH
SA14
0
1
1
1
0
0E0000H to 0EFFFFH
SA15
0
1
1
1
1
0F0000H to 0FFFFFH
SA16
1
0
0
0
0
100000H to 10FFFFH
SA17
1
0
0
0
1
110000H to 11FFFFH
SA18
1
0
0
1
0
120000H to 12FFFFH
SA19
1
0
0
1
1
130000H to 13FFFFH
SA20
1
0
1
0
0
140000H to 14FFFFH
SA21
1
0
1
0
1
150000H to 15FFFFH
SA22
1
0
1
1
0
160000H to 16FFFFH
SA23
1
0
1
1
1
170000H to 17FFFFH
SA24
1
1
0
0
0
180000H to 18FFFFH
SA25
1
1
0
0
1
190000H to 19FFFFH
SA26
1
1
0
1
0
1A0000H to 1AFFFFH
SA27
1
1
0
1
1
1B0000H to 1BFFFFH
SA28
1
1
1
0
0
1C0000H to 1CFFFFH
SA29
1
1
1
0
1
1D0000H to 1DFFFFH
SA30
1
1
1
1
0
1E0000H to 1EFFFFH
SA31
1
1
1
1
1
1F0000H to 1FFFFFH
MBM29F017A-70/-90/-12
Table 5
Sector Group Addresses
A20
A19
A18
Sectors
SGA0
0
0
0
SA0 to SA3
SGA1
0
0
1
SA4 to SA7
SGA2
0
1
0
SA8 to SA11
SGA3
0
1
1
SA12 to SA15
SGA4
1
0
0
SA16 to SA19
SGA5
1
0
1
SA20 to SA23
SGA6
1
1
0
SA24 to SA27
SGA7
1
1
1
SA28 to SA31
Write
Device erasure and programming are accomplished via the command register. The contents of the register serve
as inputs to the internal state machine. The state machine outputs dictate the function of the device.
The command register itself does not occupy any addressable memory location. The register is a latch used to
store the commands, along with the address and data information needed to execute the command. The
command register is written by bringing WE to VIL, while CE is at VIL and OE is at VIH. Addresses are latched on
the falling edge of WE or CE, whichever happens later; while data is latched on the rising edge of WE or CE,
whichever happens first. Standard microprocessor write timings are used.
Refer to AC Write Characteristics and the Erase/Programming Waveforms for specific timing parameters.
Sector Group Protection
The MBM29F017A features hardware sector group protection. This feature will disable both program and erase
operations in any combination of eight sector groups of memory. Each sector group consists of four adjacent
sectors grouped in the following pattern: sectors 0-3, 4-7, 8-11, 12-15, 16-19, 20-23, 24-27, and 28-31 (see
Table 5). The sector group protection feature is enabled using programming equipment at the user's site. The
device is shipped with all sector groups unprotected.
To activate this mode, the programming equipment must force VID on address pin A9 and control pin OE, (suggest
VID = 11.5 V), CE = VIL. The sector addresses (A20, A19, and A18) should be set to the sector to be protected.
Tables 4 and 5 define the sector address for each of the thirty two (32) individual sectors, and the sector group
address for each of the eight (8) individual group sectors. Programming of the protection circuitry begins on the
falling edge of the WE pulse and is terminated with the rising edge of the same. Sector addresses must be held
constant during the WE pulse. Refer to figures 14 and 21 for sector protection waveforms and algorithm.
To verify programming of the protection circuitry, the programming equipment must force VID on address pin A9
with CE and OE at VIL and WE at VIH. Scanning the sector addresses (A20, A19, and A18) while (A6, A1, A0) = (0,
1, 0) will produce a logical “1” code at device output DQ0 for a protected sector. Otherwise the device will produce
00H for unprotected sector. In this mode, the lower order addresses, except for A0, A1, and A6 are don’t care.
Address locations with A1 = VIL are reserved for Autoselect manufacturer and device codes.
It is also possible to determine if a sector group is protected in the system by writing an Autoselect command.
Performing a read operation at the address location XX02H, where the higher order addresses (A20, A19, and
A18) are the desired sector group address will produce a logical “1” at DQ0 for a protected sector group. See
Table 3 for Autoselect codes.
13
MBM29F017A-70/-90/-12
Temporary Sector Group Unprotection
This feature allows temporary unprotection of previously protected sector groups of the MBM29F017A device
in order to change data. The Sector Group Unprotection mode is activated by setting the RESET pin to high
voltage (12 V). During this mode, formerly protected sector groups can be programmed or erased by selecting
the sector group addresses. Once the 12 V is taken away from the RESET pin, all the previously protected sector
groups will be protected again. Refer to Figures 13 and 20.
Table 6
Command
Sequence
Bus
Write
Cycles
Req'd
MBM29F017A Command Definitions
Fifth Bus
Sixth Bus
First Bus Second Bus Third Bus Fourth Bus
Write Cycle Write Cycle
Write Cycle Write Cycle Write Cycle Read/Write
Cycle
Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data
Read/Reset*
1
XXXH F0H
Reset/Read*
3
Autoselect
—
—
—
—
—
—
—
—
—
—
XXXH AAH XXXH 55H XXXH F0H
RA
RD
—
—
—
—
3
XXXH AAH XXXH 55H XXXH 90H
—
—
—
—
—
—
Byte Program
4
XXXH AAH XXXH 55H XXXH A0H
PA
PD
—
—
—
—
Chip Erase
6
XXXH AAH XXXH 55H XXXH 80H XXXH AAH XXXH 55H XXXH 10H
Sector Erase
6
XXXH AAH XXXH 55H XXXH 80H XXXH AAH XXXH 55H
Sector Erase
Suspend
1
Erase can be suspended during sector erase with Addr (“H” or “L”). Data (B0H)
Sector Erase
Resume
1
Erase can be resumed after suspend with Addr (“H” or “L”). Data (30H)
SA
30H
Notes: 1. Bus operations are defined in Table 2.
2. RA = Address of the memory location to be read.
PA = Address of the memory location to be programmed. Addresses are latched on the falling edge
of the WE pulse.
SA = Address of the sector to be erased. The combination of A20, A19, A18, A17, and A16 will uniquely select
any sector.
3. RD = Data read from location RA during read operation.
PD = Data to be programmed at location PA. Data is latched on the rising edge of WE.
4. Read and Byte program functions to non-erasing sectors are allowed in the Erase Suspend mode.
* : Either of the two reset commands will reset the device.
Command Definitions
Device operations are selected by writing specific address and data sequences into the command register.
Writing incorrect address and data values or writing them in the improper sequence will reset the device to the
read mode. Table 6 defines the valid register command sequences. Note that the Erase Suspend (B0H) and
Erase Resume (30H) commands are valid only while the Sector Erase operation is in progress. Moreover, both
Read/Reset commands are functionally equivalent, resetting the device to the read mode.
14
MBM29F017A-70/-90/-12
Read/Reset Command
The read or reset operation is initiated by writing the read/reset command sequence into the command register.
Microprocessor read cycles retrieve array data from the memory. The device remains enabled for reads until the
command register contents are altered.
The device will automatically power-up in the read/reset state. In this case, a command sequence is not required
to read data. Standard microprocessor read cycles will retrieve array data. This default value ensures that no
spurious alteration of the memory content occurs during the power transition. Refer to the AC Read
Characteristics and Waveforms for the specific timing parameters.
Autoselect Command
Flash memories are intended for use in applications where the local CPU alters memory contents. As such,
manufacture and device codes must be accessible while the device resides in the target system. PROM
programmers typically access the signature codes by raising A9 to a high voltage. However, multiplexing high
voltage onto the address lines is not generally desirable system design practice.
The device contains an autoselect command operation to supplement traditional PROM programming
methodology. The operation is initiated by writing the autoselect command sequence into the command register.
Following the command write, a read cycle from address XX00H retrieves the manufacture code of 04H. A read
cycle from address XX01H returns the device code ADH. (See Table 3.)
All manufacturer and device codes will exhibit odd parity with the DQ7 defined as the parity bit.
Sector state (protection or unprotection) will be informed by address XX02H.
Scanning the sector group addresses (A18, A19, A20) while (A6, A1, A0) = (0, 1, 0) will produce a logical “1” at
device output DQ0 for a protected sector group.
To terminate the operation, it is necessary to write the read/reset command sequence into the register and also
to write the autoselect command during the operation, execute it after writing read/reset command sequence.
Byte Programming
The device is programmed on a byte-by-byte basis. Programming is a four bus cycle operation. There are two
“unlock” write cycles. These are followed by the program set-up command and data write cycles. Addresses are
latched on the falling edge of CE or WE, whichever happens later and the data is latched on the rising edge of
CE or WE, whichever happens first. The rising edge of CE or WE (whichever happens first) begins programming.
Upon executing the Embedded ProgramTM Algorithm command sequence, the system is not required to provide
further controls or timings. The device will automatically provide adequate internally generated program pulses
and verify the programmed cell margin.
This automatic programming operation is completed when the data on DQ7 is equivalent to data written to this
bit at which time the device returns to the read mode and addresses are no longer latched. (See Table 7, Hardware
Sequence Flags.) Therefore, the device requires that a valid address to the device be supplied by the system
at this particular instance of time. Data Polling must be performed at the memory location which is being
programmed.
Any commands written to the chip during this period will be ignored. If a hardware reset occurs during the
programming operation, it is impossible to guarantee the data are being written.
Programming is allowed in any sequence and across sector boundaries. Beware that a data “0” cannot be
programmed back to a “1”. Attempting to do so may either hang up the device or result in an apparent success
according to the data polling algorithm but a read from reset/read mode will show that the data is still “0”. Only
erase operations can convert “0”s to “1”s.
Figure 15 illustrates the Embedded Programming Algorithm using typical command strings and bus operations.
15
MBM29F017A-70/-90/-12
Chip Erase
Chip erase is a six bus cycle operation. There are two “unlock” write cycles. These are followed by writing the
“set-up” command. Two more “unlock” write cycles are then followed by the chip erase command.
Chip erase does not require the user to program the device prior to erase. Upon executing the Embedded EraseTM
Algorithm command sequence the device will automatically program and verify the entire memory for an all zero
data pattern prior to electrical erase. The system is not required to provide any controls or timings during these
operations.
The automatic erase begins on the rising edge of the last WE pulse in the command sequence and terminates
when the data on DQ7 is “1” (See Write Operation Status section.) at which time the device returns to read the
mode.
Figure 16 illustrates the Embedded EraseTM Algorithm using typical command strings and bus operations.
Sector Erase
Sector erase is a six bus cycle operation. There are two “unlock” write cycles. These are followed by writing the
“set-up” command. Two more “unlock” write cycles are then followed by the sector erase command. The sector
address (any address location within the desired sector) is latched on the falling edge of WE, while the command
(Data = 30H) is latched on the rising edge of WE. After time-out of 50 µs from the rising edge of the last sector
erase command, the sector erase operation will begin.
Multiple sectors may be erased concurrently by writing the six bus cycle operations on Table 6. This sequence
is followed with writes of the Sector Erase command to addresses in other sectors desired to be concurrently
erased. The time between writes must be less than 50 µs otherwise that command will not be accepted and
erasure will start. It is recommended that processor interrupts be disabled during this time to guarantee this
condition. The interrupts can be re-enabled after the last Sector Erase command is written. A time-out of 50 µs
from the rising edge of the last WE will initiate the execution of the Sector Erase command (s). If another falling
edge of the WE occurs within the 50 µs time-out window the timer is reset. (Monitor DQ3 to determine if the
sector erase timer window is still open, see section DQ3, Sector Erase Timer.) Any command other than Sector
Erase or Erase Suspend during this time-out period will reset the device to the read mode, ignoring the previous
command string. Resetting the device once execution has begun will corrupt the data in that sector. In that case,
restart the erase on those sectors and allow them to complete. (Refer to the Write Operation Status section for
DQ3, Sector Erase Timer operation.) Loading the sector erase buffer may be done in any sequence and with
any number of sectors (0 to 31).
Sector erase does not require the user to program the device prior to erase. The device automatically programs
all memory locations in the sector (s) to be erased prior to electrical erase. When erasing a sector or sectors
the remaining unselected sectors are not affected. The system is not required to provide any controls or timings
during these operations.
The automatic sector erase begins after the 50 µs time out from the rising edge of the WE pulse for the last
sector erase command pulse and terminates when the data on DQ7 is “1” (See Write Operation Status section.)
at which time the device returns to the read mode. Data polling must be performed at an address within any of
the sectors being erased.
Figure 16 illustrates the Embedded EraseTM Algorithm using typical command strings and bus operations.
16
MBM29F017A-70/-90/-12
Erase Suspend
The Erase Suspend command allows the user to interrupt a Sector Erase operation and then perform data reads
from or programs to a sector not being erased. This command is applicable ONLY during the Sector Erase
operation which includes the time-out period for sector erase. The Erase Suspend command will be ignored if
written during the Chip Erase operation or Embedded ProgramTM Algorithm. Writting the Erase Suspend
command during the Sector Erase time-out results in immediate termination of the time-out period and
suspension of the erase operation.
Any other command written during the Erase Suspend mode will be ignored except the Erase Resume command.
Writing the Erase Resume command resumes the erase operation. The addresses are “don't-cares” when writing
the Erase Suspend or Erase Resume command.
When the Erase Suspend command is written during the Sector Erase operation, the device will take a maximum
of 15 ms to suspend the erase operation. When the device has entered the erase-suspended mode, the RY/BY
output pin and the DQ7 bit will be at logic “1”, and DQ6 will stop toggling. The user must use the address of the
erasing sector for reading DQ6 and DQ7 to determine if the erase operation has been suspended. Further writes
of the Erase Suspend command are ignored.
When the erase operation has been suspended, the device defaults to the erase-suspend-read mode. Reading
data in this mode is the same as reading from the standard read mode except that the data must be read from
sectors that have not been erase-suspended. Successively reading from the erase-suspended sector while the
device is in the erase-suspend-read mode will cause DQ2 to toggle. (See the section on DQ2.)
After entering the erase-suspend-read mode, the user can program the device by writing the appropriate
command sequence for Byte Program. This program mode is known as the erase-suspend-program mode.
Again, programming in this mode is the same as programming in the regular Byte Program mode except that
the data must be programmed to sectors that are not erase-suspended. Successively reading from the erasesuspended sector while the device is in the erase-suspend-program mode will cause DQ2 to toggle. The end of
the erase-suspended program operation is detected by the RY/BY output pin, Data polling of DQ7, or by the
Toggle Bit I (DQ6) which is the same as the regular Byte Program operation. Note that DQ7 must be read from
the byte program address while DQ6 can be read from any address.
To resume the operation of Sector Erase, the Resume command (30H) should be written. Any further writes of
the Resume command at this point will be ignored. Another Erase Suspend command can be written after the
chip has resumed erasing.
17
MBM29F017A-70/-90/-12
Write Operation Status
Table 7
Hardware Sequence Flags
DQ7
DQ6
DQ5
DQ3
DQ2
DQ7
Toggle
0
0
1
0
Toggle
0
1
Toggle
1
1
0
0
Toggle
Erase Suspend Read
(Non-Erase Suspended Sector)
Data
Data
Data
Data
Data
Erase Suspend Program
(Non-Erase Suspended Sector)
DQ7
Toggle
(Note 1)
0
0
1
(Note 2)
DQ7
Toggle
1
0
1
0
Toggle
1
1
N/A
DQ7
Toggle
1
0
N/A
Status
TM
Embedded Program
Algorithm
Embedded EraseTM Algorithm
In progress
Erase Suspend Read
(Erase Suspended Sector)
Erase
Suspended
Mode
Embedded ProgramTM Algorithm
Exceeded
Time Limits
Embedded EraseTM Algorithm
Erase
Suspended
Mode
Erase Suspend Program
(Non-Erase Suspended Sector)
Notes: 1. Performing successive read operations from any address will cause DQ6 to toggle.
2. Reading the byte address being programmed while in the erase-suspend program mode will indicate logic
“1” at the DQ2 bit. However, successive reads from the erase-suspended sector will cause DQ2 to toggle.
3. DQ0 and DQ1 are reserved pins for future use.
4. DQ4 is Fujitsu internal use only.
DQ7
Data Polling
The MBM29F017A device features Data Polling as a method to indicate to the host that the embedded algorithms
are in progress or completed. During the Embedded ProgramTM Algorithm, an attempt to read the device will
produce the complement of the data last written to DQ7. Upon completion of the Embedded ProgramTM Algorithm,
an attempt to read the device will produce the true data last written to DQ7. During the Embedded EraseTM
Algorithm, an attempt to read the device will produce a “0” at the DQ7 output. Upon completion of the Embedded
EraseTM Algorithm an attempt to read the device will produce a “1” at the DQ7 output. The flowchart for Data
Polling (DQ7) is shown in Figure 17.
Data polling will also flag the entry into Erase Suspend. DQ7 will switch “0” to “1” at the start of the Erase Suspend
mode. Please note that the address of an erasing sector must be applied in order to observe DQ7 in the Erase
Suspend Mode.
During Program in Erase Suspend, Data polling will perform the same as in regular program execution outside
of the suspend mode.
For chip erase, the Data Polling is valid after the rising edge of the sixth WE pulse in the six write pulse sequence.
For sector erase, the Data Polling is valid after the last rising edge of the sector erase WE pulse. Data Polling
must be performed at sector address within any of the sectors being erased and not a sector that is within a
protected sector group. Otherwise, the status may not be valid.
Just prior to the completion of Embedded Algorithm operation DQ7 may change asynchronously while the output
enable (OE) is asserted low. This means that the device is driving status information on DQ7 at one instant of
time and then that byte's valid data at the next instant of time. Depending on when the system samples the DQ7
output, it may read the status or valid data. Even if the device has completed the Embedded Algorithm operations
18
MBM29F017A-70/-90/-12
and DQ7 has a valid data, the data outputs on DQ0 to DQ6 may be still invalid. The valid data on DQ0 to DQ7 will
be read on the successive read attempts.
The Data Polling feature is only active during the Embedded Programming Algorithm, Embedded Erase
Algorithm, Erase Suspend, erase-suspend-program mode, or sector erase time-out. (See Table 7.)
See Figure 8 for the Data Polling timing specifications and diagrams.
DQ6
Toggle Bit I
The MBM29F017A also features the “Toggle Bit I” as a method to indicate to the host system that the embedded
algorithms are in progress or completed.
During an Embedded Program or Erase Algorithm cycle, successive attempts to read (OE toggling) data from
the device at any address will result in DQ6 toggling between one and zero. Once the Embedded Program or
Erase Algorithm cycle is completed, DQ6 will stop toggling and valid data will be read on the next successive
attempts. During programming, the Toggle Bit I is valid after the rising edge of the fourth WE pulse in the four
write pulse sequence. For chip erase, the Toggle Bit I is valid after the rising edge of the sixth WE pulse in the
six write pulse sequence. For Sector Erase, the Toggle Bit I is valid after the last rising edge of the sector erase
WE pulse. The Toggle Bit I is active during the sector erase time out.
Either CE or OE toggling will cause the DQ6 to toggle. In addition, an Erase Suspend/Resume command will
cause DQ6 to toggle. See Figure 9 for the Toggle Bit I timing specifications and diagrams.
DQ5
Exceeded Timing Limits
DQ5 will indicate if the program or erase time has exceeded the specified limits (internal pulse count). Under
these conditions DQ5 will produce a “1”. This is a failure condition which indicates that the program or erase
cycle was not successfully completed. Data Polling is the only operating function of the device under this
condition. The CE circuit will partially power down the device under these conditions. The OE and WE pins will
control the output disable functions as described in Table 2.
The DQ5 failure condition may also appear if a user tries to program a 1 to a location that is previously programmed
to 0. In this case the device locks out and never completes the Embedded ProgramTM Algorithm. Hence, the
system never reads a valid data on DQ7 bit and DQ6 never stops toggling. Once the device has exceeded timing
limits, the DQ5 bit will indicate a “1.” Please note that this is not a device failure condition since the device was
incorrectly used. If this occurs, reset the device.
DQ3
Sector Erase Timer
After the completion of the initial sector erase command sequence the sector erase time-out will begin. DQ3 will
remain low until the time-out is complete. Data Polling and Toggle Bit I are valid after the initial sector erase
command sequence.
If Data Polling or the Toggle Bit I indicates the device has been written with a valid erase command, DQ3 may
be used to determine if the sector erase timer window is still open. If DQ3 is high (“1”) the internally controlled
erase cycle has begun; attempts to write subsequent commands (other than Erase Suspend) to the device will
be ignored until the erase operation is completed as indicated by Data Polling or Toggle Bit I. If DQ3 is low (“0”),
the device will accept additional sector erase commands. To insure the command has been accepted, the system
software should check the status of DQ3 prior to and following each subsequent sector erase command. If DQ3
were high on the second status check, the command may not have been accepted.
Refer to Table 7: Hardware Sequence Flags
19
MBM29F017A-70/-90/-12
DQ2
Toggle Bit II
This toggle bit, along with DQ6, can be used to determine whether the device is in the Embedded EraseTM
Algorithm or in Erase Suspend.
Successive reads from the erasing sector will cause DQ2 to toggle during the Embedded EraseTM Algorithm. If
the device is in the erase-suspended-read mode, successive reads from the erase-suspended sector will cause
DQ2 to toggle. When the device is in the erase-suspended-program mode, successive reads from the byte
address of the non-erase suspended sector will indicate a logic “1” at the DQ2 bit.
DQ6 is different from DQ2 in that DQ6 toggles only when the standard program or Erase, or Erase Suspend
Program operation is in progress. The behavior of these two status bits, along with that of DQ7, is summarized
as follows:
DQ7
DQ6
DQ2
DQ7
toggles
1
Erase
0
toggles
toggles
Erase Suspend Read (1)
(Erase-Suspended Sector)
1
1
toggles
DQ7 (2)
toggles
1 (2)
Mode
Program
Erase Suspend Program
Notes: 1. These status flags apply when outputs are read from a sector that has been erase-suspended.
2. These status flags apply when outputs are read from the byte address of the non-erase suspended sector.
For example, DQ2 and DQ6 can be used together to determine the erase-suspend-read mode. (DQ2 toggles
while DQ6 does not.) See also Table 7 and Figure 14.
Furthermore, DQ2 can also be used to determine which sector is being erased. When the device is in the erase
mode, DQ2 toggles if this bit is read from the erasing sector.
RY/BY
Ready/Busy
The MBM29F017A provides a RY/BY open-drain output pin as a way to indicate to the host system that the
Embedded Algorithms are either in progress or has been completed. If the output is low, the device is busy with
either a program or erase operation. If the output is high, the device is ready to accept any read/write or erase
operation. When the RY/BY pin is low, the device will not accept any additional program or erase commands
with the exception of the Erase Suspend command. If the MBM29F017A is placed in an Erase Suspend mode,
the RY/BY output will be high, by means of connecting with a pull-up resistor to VCC.
During programming, the RY/BY pin is driven low after the rising edge of the fourth WE pulse. During an erase
operation, the RY/BY pin is driven low after the rising edge of the sixth WE pulse. The RY/BY pin will indicate a
busy condition during RESET pulse. Refer to Figure 10 for a detailed timing diagram. The RY/BY pin is pulled
high in standby mode.
Since this is an open-drain output, several RY/BY pins can be tied together in parallel with a pull-up resistor to VCC.
20
MBM29F017A-70/-90/-12
RESET
Hardware Reset
The MBM29F017A device may be reset by driving the RESET pin to VIL. The RESET pin must be kept low (VIL)
for at least 500 ns. Any operation in progress will be terminated and the internal state machine will be reset to
the read mode 20 ms after the RESET pin is driven low. If a hardware reset occurs during a program operation,
the data at that particular location will be indeterminate.
When the RESET pin is low and the internal reset is complete, the device goes to standby mode and cannot be
accessed. Also, note that all the data output pins are tri-stated for the duration of the RESET pulse. Once the
RESET pin is taken high, the device requires tRH ns of wake up time until outputs are valid for read access.
The RESET pin may be tied to the system reset input. Therefore, if a system reset occurs during the Embedded
Program or Erase Algorithm, the device will be automatically reset to read mode and this will enable the system’s
microprocessor to read the boot-up firmware from the Flash memory.
Data Protection
The MBM29F017A is designed to offer protection against accidental erasure or programming caused by spurious
system level signals that may exist during power transitions. During power up the device automatically resets
the internal state machine in the Read mode. Also, with its control register architecture, alteration of the memory
contents only occurs after successful completions of specific multi-bus cycle command sequences.
The device also incorporates several features to prevent inadvertent write cycles resulting from VCC power-up
and power-down transitions or system noise.
Low VCC Write Inhibit
To avoid initiation of a write cycle during VCC power-up and power-down, a write cycle is locked out for VCC less
than VLKO (typically 3.7 V). If VCC < VLKO, the command register is disabled and all internal program/erase circuits
are disabled. Under this condition the device will reset to the read mode. Subsequent writes will be ignored until
the VCC level is greater than VLKO. It is the users responsibility to ensure that the control pins are logically correct
to prevent unintentional writes when VCC is above 3.2 V.
Write Pulse “Glitch” Protection
Noise pulses of less than 5 ns (typical) on OE, CE, or WE will not initiate a write cycle.
Logical Inhibit
Writing is inhibited by holding any one of OE = VIL, CE = VIH or WE = VIH. To initiate a write cycle CE and WE
must be a logical zero while OE is a logical one.
Power-Up Write Inhibit
Power-up of the device with WE = CE = VIL and OE = VIH will not accept commands on the rising edge of WE.
The internal state machine is automatically reset to the read mode on power-up.
Handling of SON Package
The metal portion of marking side is connected with internal chip electrically. Please pay attention not to occur
electrical connection during operation. In worst case, it may be caused permanent damage to device or system
by excessive current.
21
MBM29F017A-70/-90/-12
■ ABSOLUTE MAXIMUM RATINGS
Storage Temperature ........................................................................................–55°C to +125°C
Ambient Temperature with Power Applied ........................................................–40°C to +85°C
Voltage with Respect to Ground All pins except A9, OE, RESET (Note 1)........–2.0 V to +7.0 V
VCC (Note 1) ......................................................................................................–2.0 V to +7.0 V
A9, OE, RESET (Note 2) ...................................................................................–2.0 V to +13.5 V
Notes: 1. Minimum DC voltage on input or l/O pins are –0.5 V. During voltage transitions, inputs may negative
overshoot VSS to –2.0 V for periods of up to 20 ns. Maximum DC voltage on output and l/O pins are VCC
+0.5 V. During voltage transitions, outputs may positive overshoot to VCC +2.0 V for periods of up to 20 ns.
2. Minimum DC input voltage on A9, OE, and RESET pins are –0.5 V. During voltage transitions, A9, OE,
and RESET pins may negative overshoot VSS to –2.0 V for periods of up to 20 ns. Maximum DC input
voltage on A9, OE, and RESET pins are +13.0 V which may positive overshoot to 14.0 V for periods of
up to 20 ns.
WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current,
temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
■ RECOMMENDED OPERATING RANGES
Ambient Temperature (TA) ........................................................................... –40°C to +85°C
VCC Supply Voltages
MBM29F017A-70....................................................................................... +4.75 V to +5.25 V
MBM29F017A-90/-12................................................................................. +4.50 V to +5.50 V
Operating ranges define those limits between which the functionality of the device is guaranteed.
WARNING: The recommended operating conditions are requird in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.
22
MBM29F017A-70/-90/-12
■ MAXIMUM OVERSHOOT
20 ns
+0.8 V
20 ns
–0.5 V
–2.0 V
20 ns
Figure 1
Maximum Negative Overshoot Waveform
20 ns
VCC+2.0 V
VCC+0.5 V
+2.0 V
20 ns
Figure 2
20 ns
Maximum Positive Overshoot Waveform
20 ns
+14.0 V
+13.0 V
VCC+0.5 V
20 ns
20 ns
Note : This waveform is applied for A9, OE, and RESET.
Figure 3
Maximum Positive Overshoot Waveform
23
MBM29F017A-70/-90/-12
■ DC CHARACTERISTICS
Parameter
Symbol
Parameter Description
Test Conditions
Min.
Max.
Unit
ILI
Input Leakage Current
VIN = VSS to VCC, VCC = VCC Max.
–1.0
+1.0
µA
ILO
Output Leakage Current
VOUT = VSS to VCC, VCC = VCC Max.
–1.0
+1.0
µA
ILIT
A9, OE, RESET Inputs Leakage
Current
VCC = VCC Max.
A9, OE, RESET = 12.5 V
—
50
µA
ICC1
VCC Active Current (Note 1)
CE = VIL, OE = VIH
—
40
mA
ICC2
VCC Active Current (Note 2)
CE = VIL, OE = VIH
—
45
mA
VCC = VCC Max., CE = VIH, RESET = VIH
—
1
mA
VCC = VCC Max., CE = VCC ±0.3 V
RESET = VCC ±0.3 V
1
5
µA
VCC = VCC Max., RESET = VIL
—
1
mA
VCC = VCC Max. RESET = VSS ±0.3 V
1
5
µA
ICC3
ICC4
VCC Current (Standby)
VCC Current (Standby, Reset)
VIL
Input Low Level
—
–0.5
0.8
V
VIH
Input High Level
—
2.0
VCC+0.5
V
VID
Voltage for Autoselect and Sector
Protection (A9, OE, RESET)
—
11.5
12.5
V
VOL
Output Low Voltage Level
IOL = 12.0 mA, VCC = VCC Min.
—
0.45
V
IOH = –2.5 mA, VCC = VCC Min.
2.4
—
V
VCC–0.4
—
V
3.2
4.2
V
VOH1
Output High Voltage Level
VOH2
VLKO
IOH = –100 µA
Low VCC Lock-Out Voltage
—
Notes: 1. The ICC current listed includes both the DC operating current and the frequency dependent component
(at 6 MHz). The frequency component typically is 2 mA/MHz, with OE at VIH.
2. ICC active while Embedded Algorithm (program or erase) is in progress.
3. Applicable to sector protection function.
4. (VID –VCC) do not exceed 9 V.
24
MBM29F017A-70/-90/-12
■ AC CHARACTERISTICS
• Read Only Operations Characteristics
Parameter
Symbols
Description
Test Setup
JEDEC Standard
tAVAV
tRC
Read Cycle Time
tAVQV
tACC
tELQV
-70
-90
-12
(Note1) (Note2) (Note2) Unit
—
Min.
70
90
120
ns
Address to Output Delay
CE = VIL
OE = VIL
Max.
70
90
120
ns
tCE
Chip Enable to Output Delay
OE = VIL
Max.
70
90
120
ns
tGLQV
tOE
Output Enable to Output Delay
—
Max.
40
40
50
ns
tEHQZ
tDF
Chip Enable to Output High-Z
—
Max.
20
20
30
ns
tGHQZ
tDF
Output Enable to Output High-Z
—
Max.
20
20
30
ns
tAXQX
tOH
Output Hold Time From Addresses, CE
or OE, whichever occurs first
—
Min.
0
0
0
ns
tREADY
RESET Pin Low to Read Mode
—
Max.
20
20
20
µs
—
Note: 2. Test Conditions:
Output Load: 1 TTL gate and 100 pF
Input rise and fall times: 5 ns
Input pulse levels: 0.45 V to 2.4 V
Timing measurement reference level
Input: 0.8 V and 2.0 V
Output: 0.8 V and 2.0 V
Note: 1. Test Conditions:
Output Load: 1 TTL gate and 30 pF
Input rise and fall times: 5 ns
Input pulse levels: 0.0 V to 3.0 V
Timing measurement reference level
Input: 1.5 V
Output: 1.5 V
5.0 V
IN3064
or Equivalent
2.7 kΩ
Device
Under
Test
6.2 kΩ
CL
Diodes = IN3064
or Equivalent
Note: 1. CL = 30 pF including jig capacitance
2. CL = 100 pF including jig capacitance
Figure 4
Test Conditions
25
MBM29F017A-70/-90/-12
• Write (Erase/Program) Operations
Parameter Symbols
MB29F017A
Description
JEDEC
Standard
tAVAV
tWC
Write Cycle Time
tAVWL
tAS
tWLAX
Unit
-70
-90
-12
Min.
70
90
120
ns
Address Setup Time
Min.
0
0
0
ns
tAH
Address Hold Time
Min.
45
45
50
ns
tDVWH
tDS
Data Setup Time
Min.
30
45
50
ns
tWHDX
tDH
Data Hold Time
Min.
0
0
0
ns
—
tOES
Output Enable Setup Time
Min.
0
0
0
ns
0
0
0
ns
tOEH
Output
Read
Enable Hold
Toggle and Data Polling
Time
Min.
—
Min.
10
10
10
ns
tGHWL
tGHWL
Read Recover Time Before Write
(OE High to WE Low)
Min.
0
0
0
ns
tGHEL
tGHEL
Read Recover Time Before Write
(OE High to CE Low)
Min.
0
0
0
ns
tELWL
tCS
CE Setup Time
Min.
0
0
0
ns
tWLEL
tWS
WE Setup Time
Min.
0
0
0
ns
tWHEH
tCH
CE Hold Time
Min.
0
0
0
ns
tEHWH
tWH
WE Hold Time
Min.
0
0
0
ns
tWLWH
tWP
Write Pulse Width
Min.
35
45
50
ns
tELEH
tCP
CE Pulse Width
Min.
35
45
50
ns
tWHWL
tWPH
Write Pulse Width High
Min.
20
20
20
ns
tEHEL
tCPH
CE Pulse Width High
Min.
20
20
20
ns
tWHWH1
tWHWH1
Programming Operation
Typ.
8
8
8
µs
Typ.
1
1
1
sec
tWHWH2
tWHWH2
Sector Erase Operation (Note 1)
Max.
8
8
8
sec
—
tEOE
Delay Time from Embedded Output Enable
Max.
40
40
50
ns
—
tVCS
VCC Setup Time
Min.
50
50
50
µs
—
tVLHT
Voltage Transition Time (Note 2)
Min.
4
4
4
µs
—
tWPP
Write Pulse Width (Note 2)
Min.
100
100
100
µs
—
tOESP
OE Setup Time to WE Active (Note 2)
Min.
4
4
4
µs
—
tCSP
CE Setup Time to WE Active (Note 2)
Min.
4
4
4
µs
—
tRB
Recover Time From RY/BY
Min.
0
0
0
ns
(Continued)
26
MBM29F017A-70/-90/-12
(Continued)
Parameter Symbols
MB29F017A
Description
JEDEC
Standard
—
tRH
—
Unit
-70
-90
-12
RESET Hold Time Before Read
Min.
50
50
50
ns
tBUSY
Program/Erase Valid to RY/BY Delay
Max.
70
90
120
ns
—
tVIDR
Rise Time to VID (Note 2)
Min.
500
500
500
ns
—
tRP
RESET Pulse Width
Min.
500
500
500
ns
Notes: 1. This does not include the preprogramming time.
2. This timing is for Sector Protection operation.
27
MBM29F017A-70/-90/-12
■ SWITCHING WAVEFORMS
• Key to Switching Waveforms
WAVEFORM
INPUTS
OUTPUTS
Must Be
Steady
Will Be
Steady
May
Change
from H to L
Will Be
Changing
from H to L
May
Change
from L to H
Will Be
Changing
from L to H
H or L
Any Change
Permitted
Changing,
State
Unknown
Does Not
Apply
Center Line is
HighImpedance
“Off” State
t RC
Addresses Stable
A 0 to A 20
t ACC
CE
t OE
t DF
OE
t OEH
WE
t CE
DQ 0 to DQ 7
High-Z
Output Valid
Table 5 .1 AC Waveforms for Read Operations
28
MBM29F017A-70/-90/-12
t RC
Addresses Stable
A 0 to A 20
t ACC
t RH
RESET
t OH
DQ 0 to DQ 7
High-Z
Output Valid
Table 5 .2 AC Waveforms for Read Operations
29
MBM29F017A-70/-90/-12
3rd Bus Cycle
Data Polling
XXXH
A 0 to A 20
t WC
PA
t AS
PA
t AH
t RC
CE
t CS
t CH
t CE
OE
t WP
t WHWH1
t WPH
t OE
t GHWL
WE
t DS
t OH
t DH
A 0H
Data
Notes: 1.
2.
3.
4.
5.
DQ 7
D OUT
PA is address of the memory location to be programmed.
PD is data to be programmed at byte address.
DQ7 is the output of the complement of the data written to the device.
DOUT is the output of the data written to the device.
Figure indicates last two bus cycles of four bus cycle sequence.
Figure 6
30
PD
Alternate WE Controlled Program Operation Timings
D OUT
MBM29F017A-70/-90/-12
3rd Bus Cycle
Data Polling
PA
XXXH
A 0 to A 20
t AS
t WC
PA
t AH
WE
t WS
t WH
OE
t GHEL
t CP
t CPH
t WHWH1
CE
t DS
Data
Notes: 1.
2.
3.
4.
5.
t DH
A 0H
PD
DQ 7
D OUT
PA is address of the memory location to be programmed.
PD is data to be programmed at byte address.
DQ7 is the output of the complement of the data written to the device.
DOUT is the output of the data written to the device.
Figure indicates last two bus cycles of four bus cycle sequence.
Figure 7
Alternate CE Controlled Program Operation Timings
31
MBM29F017A-70/-90/-12
XXXH
A 0 to A 20
XXXH
t WC
t AS
XXXH
XXXH
XXXH
SA
t AH
CE
t CS
t CH
OE
t WP
t GHWL
t WPH
WE
t DS
t DH
AAH
Data
55H
80H
AAH
55H
t VCS
V CC
Note: SA is the sector address for Sector Erase. Addresses = ×××H for Chip Erase.
Figure 8
32
AC Waveforms Chip/Sector Erase Operations
10H/30H
MBM29F017A-70/-90/-12
tCH
CE
tDF
tOE
OE
tOEH
WE
tCE
*
DQ7
DQ7 =
Valid Data
DQ7
High-Z
tWHWH1 or 2
DQ0 to DQ6
DQ0 to DQ6 = Invalid
DQ0 to DQ6
Valid Data
High-Z
tOE
* : DQ7 = Valid Data (The device has completed the Embedded operation).
Figure 9
AC Waveforms for Data Polling During Embedded Algorithm Operations
CE
tOEH
WE
tOES
OE
*
Data
(DQ0 to DQ7)
DQ6 = Toggle
DQ6 =
Stop Toggling
DQ6 = Toggle
DQ0 to DQ7
Valid
tOE
* : DQ6 = Stops Toggling (The device has completed the Embedded operation).
Figure 10
AC Waveforms for Toggle Bit I During Embedded Algorithm Operations
33
MBM29F017A-70/-90/-12
CE
The rising edge of the last WE signal
WE
Entire programming
or erase operations
RY/BY
tBUSY
Figure 11
RY/BY Timing Diagram During Program/Erase Operations
WE
RESET
t RB
t RP
RY/BY
t READY
Figure 12
34
RESET Timing Diagram
MBM29F017A-70/-90/-12
A 20, A 19, A 18
SGA X
SGA Y
A0
A1
A6
V ID
5V
A9
t VLHT
OE
t VLHT
V ID
5V
t OESP
t WPP
t VLHT
t VLHT
WE
t CSP
CE
01H
Data
t OE
t VCS
V CC
SGAX = Sector Group Address for initial sector
SGAY = Sector Group Address for next sector
Figure 13
AC Waveforms for Sector Group Protection
35
MBM29F017A-70/-90/-12
VCC
tVIDR
tVCS
tVLHT
VID
5V
5V
RESET
CE
WE
tVLHT
tVLHT
Program or Erase Command Sequence
RY/BY
Unprotection period
Figure 14
Enter
Embedded
Erasing
WE
Erase
Suspend
Erase
Temporary Sector Group Unprotection
Enter Erase
Suspend Program
Erase Suspend
Read
Erase
Suspend
Program
Erase
Resume
Erase Suspend
Read
DQ6
DQ2
Toggle
DQ2 and DQ6
with OE
Note: DQ2 is read from the erase-suspended sector.
Figure 15
36
DQ2 vs. DQ6
Erase
Erase
Complete
MBM29F017A-70/-90/-12
EMBEDDED ALGORITHMS
Start
Write Program Command
Sequence
(See Below)
Data Polling Device
Increment Address
No
Last Address
?
Yes
Programming Completed
Program Command Sequence (Address/Command):
×××H/AAH
×××H/55H
×××H/A0H
Program Address/Program Data
Figure 16
Embedded Programming Algorithm
37
MBM29F017A-70/-90/-12
EMBEDDED ALGORITHMS
Start
Write Erase Command
Sequence
(See Below)
Data Polling or Toggle Bit
Successfully Completed
Erasure Completed
Chip Erase Command Sequence*
(Address/Command):
Individual Sector/Multiple Sector*
Erase Command Sequence
(Address/Command):
×××H/AAH
×××H/AAH
×××H/55H
×××H/55H
×××H/80H
×××H/80H
×××H/AAH
×××H/AAH
×××H/55H
×××H/55H
×××H/10H
Sector Address/30H
Sector Address/30H
Additional sector
erase commands
are optional.
Sector Address/30H
Note: To insure the command has been accepted, the system software should check the status
of DQ3 prior to and following each subsequent sector erase command. If DQ3 were high on
the second status check, the command may not have been accepted.
Figure 17
38
Embedded EraseTM Algorithm
MBM29F017A-70/-90/-12
Start
VA = Byte address for programming
= Any of the sector addresses
within the sector being erased
during sector erase operation
= Any of the sector group address
within the sector not being
protected during chip erase
operation.
Read Byte
(DQ0 to DQ7)
Addr. = VA
DQ7 = Data?
Yes
No
No
DQ5 = 1?
Yes
Read Byte
(DQ0 to DQ7)
Addr. = VA
DQ7 = Data?
Yes
No
Fail
Pass
Note: DQ7 is rechecked even if DQ5 = “1” because DQ7 may change simultaneously with DQ5.
Figure 18
Data Polling Algorithm
39
MBM29F017A-70/-90/-12
Start
Read Byte
(DQ0 to DQ7)
Addr. = “H” or “L”
No
DQ6 = Toggle
?
Yes
No
DQ5 = 1?
Yes
Read Byte
(DQ0 to DQ7)
Addr. = “H” or “L”
DQ6 = Toggle
?
No
Yes
Fail
Pass
Note: DQ6 is rechecked even if DQ5 = “1” because DQ6 may stop toggling at the same time as DQ5
changing to “1”.
Figure 19
40
Toggle Bit I Algorithm
MBM29F017A-70/-90/-12
Start
Set Up Sector Addr.
(A20, A19, A18)
PLSCNT = 1
OE = VID, A9 = VID,
CE = VIL, RESET = VIH
Activate WE Pulse
Time out 100 µs
Increment PLSCNT
WE = VIH, CE = OE = VIL
A9 should remain VID
Read from Sector
Addr. (A20, A19, A18)
A1 = 1, A0 = A6 = 0
No
No
PLSCNT = 25?
Data = 01H?
Yes
Yes
Remove VID from A9
Write Reset Command
Yes
Protect Another Sector?
No
Device Failed
Remove VID from A9
Write Reset Command
Sector Protection
Completed
Figure 20
Sector Group Protection Algorithm
41
MBM29F017A-70/-90/-12
Start
RESET = VID
(Note 1)
Perform Erase or
Program Operations
RESET = VIH
Temporary Sector
Unprotection Completed
(Note 2)
Notes: 1. All Protected sector groups unprotected.
2. All previously protected sector groups are protected once again.
Figure 21
42
Temporary Sector Group Unprotection Algorithm
MBM29F017A-70/-90/-12
■ ERASE AND PROGRAMMING PERFORMANCE
Limits
Parameter
Unit
Comments
Min.
Typ.
Max.
Sector Erase Time
—
1
8
sec
Excludes 00H programming
prior to erasure
Byte Programming Time
—
8
150
µs
Excludes system-level
overhead
Chip Programming Time
—
16.8
40
sec
Excludes system-level
overhead
100,000
—
—
Cycles
Erase/Program Cycle
■ TSOP PIN CAPACITANCE
Parameter
Symbol
Parameter Description
Test Setup
Typ.
Max.
Unit
CIN1
Input Capacitance
VIN = 0
8
10
pF
COUT
Output Capacitance
VOUT = 0
8
10
pF
CIN2
Control Pin Capacitance
VIN = 0
9
10
pF
Typ.
Max.
Unit
Note: Test conditions TA = 25°C, f = 1.0 MHz
■ SON PIN CAPACITANCE
Parameter
Symbol
Parameter Description
Test Setup
CIN1
Input Capacitance
VIN = 0
8
10
pF
COUT
Output Capacitance
VOUT = 0
8
10
pF
CIN2
Control Pin Capacitance
VIN = 0
9
10
pF
Note: Test conditions TA = 25°C, f = 1.0 MHz
43
MBM29F017A-70/-90/-12
■ PACKAGE DIMENSIONS
* Resin Protrusion:(Each Side:0.15(.006)MAX)
48-pin Plastic TSOP (I)
(FPT-48P-M19)
LEAD No.
48
1
Details of "A" part
INDEX
0.15(.006)
MAX
0.35(.014)
MAX
"A"
0.15(.006)
25
24
* 12.00±0.20
(.472±.008)
11.50REF
(.460)
20.00±0.20
(.787±.008)
* 18.40±0.20
(.724±.008)
0.10(.004)
19.00±0.20
(.748±.008)
1996 FUJITSU LIMITED F48029S-2C-2
+0.10
1.10 −0.05
+.004
.043 −.002
(Mounting height)
0.05(0.02)MIN
STAND OFF
0.50(.0197)
TYP
0.15±0.05
(.006±.002)
C
0.25(.010)
0.20±0.10
(.008±.004)
0.10(.004)
M
0.50±0.10
(.020±.004)
Dimensions in mm(inches)
(Continued)
44
MBM29F017A-70/-90/-12
* Resin Protrusion:(Each Side:0.15(.006)MAX)
48-pin Plastic TSOP (I)
(FPT-48P-M20)
LEAD No.
48
1
Details of "A" part
INDEX
0.15(.006)
MAX
0.35(.014)
MAX
"A"
0.15(.006)
0.25(.010)
25
24
19.00±0.20
(.748±.008)
0.50±0.10
(.020±.004)
0.20±0.10
(.008±.004)
0.15±0.10
(.006±.002)
0.10(.004)
0.50(.0197)
TYP
0.10(.004)
M
0.05(0.02)MIN
STAND OFF
+0.10
* 18.40±0.20
(.724±.008)
20.00±0.20
(.787±.008)
C
1996 FUJITSU LIMITED F48030S-2C-2
11.50(.460)REF
1.10 −0.05
+.004
.043 −.002
(Mounting height)
* 12.00±0.20(.472±.008)
Dimensions in mm(inches)
(Continued)
45
MBM29F017A-70/-90/-12
(Continued)
40-pin Plastic SON
(LCC-40P-M02)
*10.75±0.10(.423±.004)
0.75(.030)MAX
(TOTAL HEIGHT)
40
0.50(.020)TYP
"A"
21
10.10±0.20
(.398±.008)
10.00±0.10
(.394±.004)
20
1
INDEX
0.05(.002)
M
Details of "B" part
Details of "A" part
*0.625(.025)TYP
"B"
0.10(.004)TYP
0.05(.002)
C
46
1997 FUJITSU LIMITED C40052S-4C-3
0(0)MIN
(STAND OFF)
0.50(.020)TYP
0.32±0.05
(.013±.002)
Dimensions in mm(inches)
MBM29F017A-70/-90/-12
FUJITSU LIMITED
For further information please contact:
Japan
FUJITSU LIMITED
Corporate Global Business Support Division
Electronic Devices
KAWASAKI PLANT, 4-1-1, Kamikodanaka
Nakahara-ku, Kawasaki-shi
Kanagawa 211-8588, Japan
Tel: 81(44) 754-3763
Fax: 81(44) 754-3329
http://www.fujitsu.co.jp/
North and South America
FUJITSU MICROELECTRONICS, INC.
Semiconductor Division
3545 North First Street
San Jose, CA 95134-1804, USA
Tel: (408) 922-9000
Fax: (408) 922-9179
Customer Response Center
Mon. - Fri.: 7 am - 5 pm (PST)
Tel: (800) 866-8608
Fax: (408) 922-9179
http://www.fujitsumicro.com/
Europe
FUJITSU MIKROELEKTRONIK GmbH
Am Siebenstein 6-10
D-63303 Dreieich-Buchschlag
Germany
Tel: (06103) 690-0
Fax: (06103) 690-122
http://www.fujitsu-ede.com/
Asia Pacific
FUJITSU MICROELECTRONICS ASIA PTE LTD
#05-08, 151 Lorong Chuan
New Tech Park
Singapore 556741
Tel: (65) 281-0770
Fax: (65) 281-0220
All Rights Reserved.
The contents of this document are subject to change without
notice. Customers are advised to consult with FUJITSU sales
representatives before ordering.
The information and circuit diagrams in this document are
presented as examples of semiconductor device applications,
and are not intended to be incorporated in devices for actual use.
Also, FUJITSU is unable to assume responsibility for
infringement of any patent rights or other rights of third parties
arising from the use of this information or circuit diagrams.
FUJITSU semiconductor devices are intended for use in
standard applications (computers, office automation and other
office equipment, industrial, communications, and measurement
equipment, personal or household devices, etc.).
CAUTION:
Customers considering the use of our products in special
applications where failure or abnormal operation may directly
affect human lives or cause physical injury or property damage,
or where extremely high levels of reliability are demanded (such
as aerospace systems, atomic energy controls, sea floor
repeaters, vehicle operating controls, medical devices for life
support, etc.) are requested to consult with FUJITSU sales
representatives before such use. The company will not be
responsible for damages arising from such use without prior
approval.
Any semiconductor devices have an inhereut chance of
failure. You must protect against injury, damage or loss from
such failures by incorporating safety design measures into your
facility and equipment such as redundancy, fire protection, and
prevention of over-current levels and other abnormal operating
conditions.
If any products described in this document represent goods or
technologies subject to certain restrictions on export under the
Foreign Exchange and Foreign Trade Law of Japan, the prior
authorization by Japanese government will be required for
export of those products from Japan.
http://www.fmap.com.sg/
F9903
 FUJITSU LIMITED Printed in Japan
47