MCC 6A1

MCC
6A05
THRU
6A10
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
Features
•
•
•
•
•
Low Cost
Low Forward Voltage Drop
High Current Capability
High Surge Current Capability
Low Leakage
6 Amp Rectifier
50 - 1000 Volts
Maximum Ratings
•
•
•
R-6
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
Maximum Thermal Resistance; 10 °C/W Junction To Ambient
MCC
Catalog
Number
Device
Marking
6A05
6A1
6A2
6A4
6A6
6A8
6A10
---------------
Maximum
Recurrent
Peak
Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000V
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
D
35V
70V
140V
280V
420V
560V
700V
50V
100V
200V
400V
600V
800V
1000V
A
Cathode
Mark
B
D
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
IF(AV)
6.0A
TA = 60°C
Current
Peak Forward Surge
IFSM
400A
8.3ms, half sine
Current
Maximum
0.95V
IFM = 6.0A;
Instantaneous
VF
Forward Voltage
TJ = 25°C*
Maximum DC
Reverse Current At
IR
10µA
TJ = 25°C
Rated DC Blocking
100µA
TJ = 100°C
Voltage
Typical Junction
CJ
150pF
Measured at
Capacitance
1.0MHz, VR=4.0V
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
C
DIMENSIONS
DIM
A
B
C
D
INCHES
MIN
.340
.340
.048
1.000
www.mccsemi.com
MAX
.360
.360
.052
---
MM
MIN
8.60
8.60
1.20
25.40
MAX
9.10
9.10
1.30
---
NOTE
MCC
6A05 thru 6A10
Figure 1
Typical Forward Characteristics
200
Figure 2
Forward Derating Curve
100
6
60
40
5
20
Amps
PC BOARD
4
10
6
3
Amps
4
2
2
PC BOARD
25°C
1
1
Single Phase, Half Wave
60Hz Resistive or Inductive Load
.6
0
.4
50
0
75
100
125
150
175
°C
.2
.1
.6
.8
1.0
1.2
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
1.6
1.4
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Figure 3
Typical Thermal Resistance versus Lead Length
20
15
°C/W
10
5
0
.1
.2
.3
.4
.5
.6
.7
.8
.9
1.0
Inches
Thermal Resistance - °C/W versus
Equal Lead Length To Heat Sink - Inches
www.mccsemi.com
1.1
MCC
6A05 thru 6A10
Figure 4
Typical Reverse Characteristics
Figure 5
Maximum Non-Repetitive Forward Surge Current
100
600
60
40
500
20
400
10
300
6
Amps
4
200
100
5
0
2
TJ=100°C
µAmps 1
.6
1
2
4
6
8 10
60 80 100
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
.2
.1
.06
.04
.01
40
Cycles
.4
.02
20
TJ=25°C
20
40
60
80
100
120
140
Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
www.mccsemi.com