MCC RL204GP

MCC
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
Features
•
•
•
•
•
RL201GP
THRU
RL207GP
2 Amp Glass
Passivated Rectifier
50 to 1000 Volts
Low Cost
Low Leakage
Low Forward Voltage Drop
High Current Capability
Glass Passivated Junction
DO-15
Maximum Ratings
•
•
•
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
Typical Thermal Resistance (R θJA) 50°C/W
Microsemi
Catalog
Number
Device
Marking
RL201GP
RL202GP
RL203GP
RL204GP
RL205GP
RL206GP
RL207GP
---------------
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000V
Maximum
RMS
Voltage
35V
70V
140V
280V
420V
560V
700V
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
800V
1000V
D
A
Cathode
Mark
B
D
C
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
IF(AV)
2A
TA = 75°C
Current
Peak Forward Surge
IFSM
60A
8.3ms, half sine
Current
IFM = 2.0A;
Maximum
1.0V
Instantaneous
VF
TA = 25°C
Forward Voltage
Maximum DC
Reverse Current At
IR
5.0µA
TA = 25°C
Rated DC Blocking
50µA
TA = 100°C
Voltage
Typical Junction
CJ
20pF
Measured at
Capacitance
1.0MHz, VR=4.0V
*Pulse Test: Pulse Width 300µsec, Duty Cycle 1%
DIMENSIONS
DIM
A
B
C
D
INCHES
MIN
.230
.104
.026
1.000
www.mccsemi.com
MAX
.300
.140
.034
---
MM
MIN
5.80
2.60
.70
25.40
MAX
7.60
3.60
.90
---
NOTE
MCC
RL201GP thru RL207GP
Figure 1
Typical Forward Characteristics
20
Figure 2
Forward Derating Curve
10
3.0
6
4
2.5
2
25°C
µAmps
2.0
1
.6
1.5
Amps
.4
1.0
.2
.5
.1
Single Phase, Half Wave
60Hz Resistive or Inductive Load
.06
0
.04
0
50
75
100
125
150
175
°C
.02
.01
.2
.4
.6
.8
1.0
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
1.2
Volts
Instantaneous Forward Current - MicroAmperesversus
Instantaneous Forward Voltage - Volts
Figure 3
Junction Capacitance
100
60
40
20
pF
TJ=25°C
10
6
4
2
1
.1
.2
.4
1
Volts
2
4
10
20
40
100
200
Junction Capacitance - pFversus
Reverse Voltage - Volts
www.mccsemi.com
400
1000
MCC
RL201GP thru RL207GP
Figure 4
Typical Reverse Characteristics
Figure 5
Peak Forward Surge Current
120
10
6
100
4
80
2
TJ=100°C
60
1
Amps
.6
40
.4
20
.2
0
Amps .1
1
2
4
6
8 10
40
60 80 100
Cycles
.06
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
.04
TJ=25°C
.02
.01
.006
.00
4
.002
.001
20
20
40
60
80
100
120
140
Volts
Instantaneous Reverse Current - Ampsversus
Percent Of Rated Peak Reverse Voltage - Volts
www.mccsemi.com