CHENYI MR758

MR750
thru
MR7510
Shanghai Lunsure Electronic
Technology Co.,Ltd
Tel:0086-21-37185008
Fax:0086-21-57152769
Features
•
•
•
•
•
Low Cost
Low Forward Voltage Drop
High Current Capability
High Surge Current Capability
Low Leakage
6 Amp Rectifier
50 - 1000 Volts
Maximum Ratings
•
•
•
LEADED BUTTON
Operating Temperature: -65°C to +175°C
Storage Temperature: -65°C to +175°C
Maximum Thermal Resistance; 10 °C/W Junction To Ambient
A
Catalog
Number
MR750
MR751
MR752
MR754
MR756
MR758
MR7510
Device
Marking
---------------
Maximum
Reccurrent
Peak
Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000V
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
35V
70V
140V
280V
420V
560V
700V
50V
100V
200V
400V
600V
800V
1000V
C
Mark
B
D
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum
Instantaneous
Forward Voltage
IF(AV)
6.0A
TA = 60°C
IFSM
400A
8.3ms, half sine
VF
0.9V
1.25V
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR
25µA
1.0mA
IFM = 6.0A;
TJ = 25°C*
IFM = 100A;
TJ = 25°C
DIMENSIONS
DIM
A
B
C
D
INCHES
MIN
.332
.234
.050
.990
TJ = 25°C
TJ = 100°C
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
www.cnelectr.com
MAX
.342
.246
.053
1.010
MM
MIN
8.43
5.94
1.27
25.15
MAX
8.69
6.25
1.35
25.65
NOTE
2PL
MR750 thru MR7510
Figure 1
Typical Forward Characteristics
200
Figure 2
Forward Derating Curve
100
6
60
40
5
20
Amps
4
10
6
3
Amps
4
2
2
25°C
1
1
Single Phase, Half Wave
60Hz Resistive or Inductive Load
.6
0
.4
50
0
75
100
125
150
175
°C
.2
.1
.8
.9
1.0
1.1
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
1.3
1.2
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Figure 3
Typical Thermal Resistance versus Lead Length
20
15
°C/W
10
5
0
.1
.2
.3
.4
.5
.6
.7
.8
.9
1.0
Inches
Thermal Resistance - °C/W versus
Equal Lead Length To Heat Sink - Inches
www.cnelectr.com
1.1
MR750 thru MR7510
Figure 4
Typical Reverse Characteristics
Figure 5
Maximum Non-Repetitive Forward Surge Current
100
600
60
40
500
20
400
10
300
6
Amps
4
200
100
5
0
2
TJ=100°C
µAmps 1
1
2
4
6
.6
40
60 80 100
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
.2
.1
.06
.04
.01
20
Cycles
.4
.02
8 10
TJ=25°C
20
40
60
80
100
120
140
Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
www.cnelectr.com